You are on page 1of 4

Shunts

Shunts are the first choice for accurate measuring of current in DC installations. By measuring a standarized voltage-drop at a given input-current, the
actuel current can be displaied very accurate (accuracy class 0,5) e.g. with
a moving coil instrument. Our Shunts are robust, accurate, and easy to
mount.

Shunts according to DIN 43 703 I Class 0,5

1 A to 25.000 A

07

On request
- Class 0,2
- Class 0,1
- Special voltages
- Special executions

page 7/1

<#>
3

SHUNTS

07

SHUNTS
Shunts
Shunts according to DIN 43 703
Accuracy class 0,5

Shunts are the first choice for accurate measuring of current in DC installations. By measuring a standarized voltage-drop at a given input-current, the
actuel current can be displaied very accurate (accuracy class 0,5) e.g. with
a moving coil instrument. Our Shunts are robust, accurate, and easy to
mount.

Technical Features
Rated
current
A

Our Shunts accord to the standards DIN and CEI. Using high-quality manganin for the Shunts assures a steady voltage drop for a long time and
under extreme conditions.
Standard voltage drops are 60mV and 150 mV. Shunts for 60mV can be
loaded to a maximum of 0,25 ohm. If this is insufficient, e.g. in case of a
long lead, Shunts of 150mV are recommended.
Overload capacity:
Continuously:
For 5 Seconds:

1,2
from
10 A- 500A: 10
from 501A- 2000A: 5
from 2001A- 10000A: 2

In
In
In
In

Ambient temperature:
Shunts are calibrated at 20C 10C. At this temperature the shunts meet
their accuracy class. Operating temperature: -20C to +60C. Shunts can
be overheated short-time up to 300C.
Installation:
Please consider the following instructions:
1. Shunts can be mounted horizontally or vertically. Horizontal mounting
allows a better heat dissipation.
2. The full connecting area must be in contact with the busbar.
3. The contact surfaces have to be clean.
4. Bolts and nuts must be fully tightened.
5. Sustain to get a good ventilation.
Shunts up to 25 A / 60 mV or 150 mV are delivered with insulating thermoplastic base.
Available special executions:
Covers are available for shunts up to 150A/60mV and 25A/150mV.
- Shunts 30A/ up to 800A/60mV or 150mV can also be delivered
with insulating thermoplastic base (additional charge).
- Shunts with non-standard voltage-drop or non-standard rated current.
- Shunts by customers requirements (if technically realisable).
- Shunts in accuracy class 0,2 or 0,1.
1

out of DIN-Norms

1
1,5
21
2,5
31
4
51
6
8
10
12 1
15
20 1
25
30 1
40
50 1
60
75
80 1
100
150
200 1
250
300 1
400
500 1
600
750 1
800 1
1000
1200 1
1250 1
1500
2000 1
2500
3000 1
4000
5000 1
6000
8000 1
10000
12000 1
15000
20000 1
25000 1
available

60 mV
Voltage
drop

O
O
O
O
O
O
O
O
O
O

Weight

150 mV

kg

Voltage
drop

0,12
0,13
0,13
0,12
0,12
0,13
0,12
0,12
0,13
0,13
0,13
0,13
0,13
0,13
0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,13
0,13
0,61
0,61
0,83
0,83
0,85
0,89
0,90
1,45
1,45
1,60
1,96
2,30
2,90
3,00
4,25
4,30
10,50
12,00
21,00
26,00
32,00
44,00
O

O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

Weight

300mV

Weight

kg

Voltage
drop

kg

O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

0,14
0,14
0,14
0,14
0,14
0,14
0,14
0,14
0,15
0,15
0,15
0,15
0,16
0,16
0,20
0,20
0,20
0,20
0,20
0,20
0,25
0,30
0,40
0,80
0,90
1.30
1,40
1,60
O
1,80
2,80
3,10
O
3,70
4,40
6,00
6,90
13,10
13,90
17,70

0,12
0,12
0,12
0,12
0,12
0,12
0,12
0,13
0,13
0,13
0,13
0,13
0,14
0,14
0,15
0,16
0,16
0,17
0,17
0,18
0,20
0,23
0,26
0,68
0,72
1,05
1,15
1,16
O
1,30
2,15
2,25
O
3,10
4,00
5,20
7,00
8,30
10,60
15,18
25,00
28,00

O on request

Shunts with non-standard voltage-drop or non-standard rated current on


request.

7/1

07

SHUNTS
Dimensions:
Fig. 1 (Form A)

Fig. 2 (Form B)

Fig. 3 (Form C)

h
d

15

10

Insulating base only up to 25A

g
f

c
e

30

f
c

135
115

b
a

b
a

b
a

Dimensions
Forma A (Fig.1):
Dimensions in
mm
a
b
c
d
e

Voltage drop 60 mV
1 A... 25 A
30 A...150 A
90
100
78
80
20
20
8
8
M5
M8

Voltage drop 100 mV1


1 A... 25 A
30 A...150 A
90
145
78
125
20
25
8
8
M5
M8

Voltage drop 150 mV


1 A... 25 A
30 A...150 A
90
225
78
205
20
25
8
8
M5
M8

Voltage drop 300 1mV


1 A... 25 A
30 A...150 A
90
384
78
364
20
25
8
8
M5
M8

Forma B (Fig.2):

a
b
c
d
e
f
g
Quantity of
current terminals

200A
250A
300A
145
105
30
30
15
M12

400A
500A
600A
800A
145
105
40
30
20
M16

1000A
1200A
165
115
60
30
30
M20

1500A
2000A
165
115
90
30
21
48
M16

2x1

2x1

2x1

2x1

Voltage drop 100 1mV

Voltage drop 150 mV

2500A
165
115
120
30
30
60
M20

200A
250A
300A
190
150
30
30
15
M12

400A
500A
600A
800A
190
150
40
30
20
M16

1000A
1200A
210
160
60
30
30
M20

1500A
2000A
210
160
120
30
30
60
M20

200A
250A
300A
270
230
30

400A
500A
600A
800A
210
230
40

1000A
1200A
290
240
70

302
15
M12

302
20
M16

2x1

2x1

2x1

2x1

2x1

2x1

2x1

Voltage drop 300 1mV

302
35
M20

200A
250A
300A
429
389
30
30
15
M12

400A
500A
600A
800A
429
389
40
30
20
M16

1000A
1200A
449
399
70
30
35
M20

2x1

2x1

2x1

2x1

SHUNTS

Voltage drop 60 mV
Dimensions in
mm

Forma C (Fig.3):
Voltage drop 100 mV1

Voltage drop 60 mV
Dimensions in
mm
a
b
c
d
e
f
g
h
Quantity of
current terminals

Voltage drop 300 mV1

Voltage drop 150 mV

3000A
4000A
145
115
120
60
30
60
M20
15

5000A
6000A
175
125
154
130
25
52
M20
25

8000A
10000A
185
135
206
170
25
52
M20
30

15000A
185
135
310
170
25
52
M20
30

2500A
3000A
210
160
120
60
30
60
M20
15

4000A
5000A
220
170
120
130
30
60
M20
25

6000A
220
170
154
130
25
52
M20
25

1500A
290
240
90
60
21
48
M16
15

2000A
2500A
290
240
120
60
30
60
M20
15

3000A
4000A
300
250
120
130
30
60
M20
25

5000A
6000A
300
250
154
130
25
52
M20
25

8000A
10000A
310
260
206
170
25
52
M20
30

1500A
2000A
449
399
90
60
21
48
M16
15

2500A
3000A
449
399
120
60
30
60
M20
15

4000A
5000A
459
409
120
130
30
60
M20
25

6000A
459
409
154
130
25
52
M20
25

2x2

2x3

2x4

2x6

2x2

2x2

2x3

2x2

2x2

2x2

2x3

2x4

2x2

2x2

2x2

2x3

1 out of DIN-Norms
2 out of DIN-Dimensions

7/2