Professional Documents
Culture Documents
Abstract
In this document I'll show you how to solve problem with Protg 3.2.1 with OWL-S Plugin for
semantic markup of Atomic Web Services and Composite Web Services in Windows 7
operating system. It's really a pain in the ass struggle with all this software components working
together very good.
1. Current context.
When you try to use OWL-S Editor in Protg 3.2.1 you get the following errors.
2. Software components.
You must download and install the following software components.
Protg
3.2.1
(With
Java
Virtual
Machine).
You
can
download
from
here:
http://protegewiki.stanford.edu/wiki/Protege_Desktop_Old_Versions.
Graphviz
2.28.
You
can
download
from
here:
http://www.graphviz.org/pub/graphviz/stable/windows/.
OWL-S Plugin build 23 (not working with build 24. Build 23 includes OWL-S 1.2
specification).
You
can
download
from
here:
http://projects.semwebcentral.org/frs/?group_id=25
3. Procedure.
3.1 Install
Protg
as
usual
but
notice
the
install
directory
(e.g.
C:\Program
but
notice
the
install
directory
(e.g.
C:\Program
Files\Protege_3.2.1).
3.2 Install
Graphviz
as
usual
3.3 Unzip OWL-S Plugin and copy folder 'com.sri.owlseditor' into Protg Plugins directory (e.g.
C:\Program Files\Protege_3.2.1\plugins).
3.4 Start
Protg
by
clicking
Protg.exe
(e.g.
C:\Program
3.7 Go to OWL-S Editor tab and click in Options icon (upper left buttons in OWL-S Editor).
3.8 Change Graphviz path for the full path to dot.exe. You'll need the installation path of
Graphviz
(e.g.
the
full
path
to
dot.exe
is
C:\Program
Files\Graphviz
4. Test.
4.1 Into OWL-S Editor tab, click in WSDL icon (upper left buttons in OWL-S Editor).