Professional Documents
Culture Documents
Graduate Student, Department of Civil Engineering, Chulalongkorn University, Bangkok 10330, Thailand,
suraparb@hotmail.com
2
Associate Professor, Department of Civil Engineering, Chulalongkorn University, Bangkok 10330,
Thailand, boonchai.uk@gmail.com
Abstract
At present, design processes of structures have become complicated such as those in offshore
engineering or large bridge structures, etc. Generally, piles used in supporting those structures carry
loads not only the vertical load direction, but also the horizontal direction arising from wave forces
in the sea, wind loading or forces of earthquake actions. Those forces may result in damages and
failures of structures if considering only the vertical direction. This research presents a study of
undrained stability of embedded wall in clay subjected to combined horizontal load and moment.
The 2D plane strain condition is considered in this analysis. The objective of this research is to
determine the failure envelope of embedded wall subjected to horizontal load and moment. The
studied parameters include untrained shear strength of the clay layer, the thickness of the wall (D),
and wall embedded length (L). The results of analyses are presented in terms of dimensionless
graph between normalized horizontal load, moment, and ratio of wall length to thickness (L/D).
Finite element software, PLAXIS was used in this analysis. The embedded wall is set to have
property of linear elastic material without failure consideration, while the clay is modeled as the
Mohr-Coulomb material. The analyses consider ratio of wall length to thickness, ranging from 5-80
for wide practical applications. Series of failure envelopes were determined for each value of L/D.
Results of this research can be applied in design and analysis of embedded walls, where their
results are more accurate. In addition, they provide preliminary calculations for the similar loading
cases of single pile in 3D problems.
Introduction
In designing pile foundations of complex structures such as foundations of offshore
structures or large structures such as bridges or high-rise buildings, it is not valid to
consider loading of pile foundations of those structures to exist only the vertical load
direction. Instead, loading considerations should include horizontal load direction as well
as overturning moment in order to model the most realistic state. This is because in reality
forces acting on those structures may include wave forces, wind loadings, or dynamics
forces from earthquake actions. Such forces can cause horizontal load and moment acting
on the top of individual pile. In the past, several research works presented calculations of
ultimate lateral pile resistance, where comparisons of those methods were made in terms of
advantages and disadvantages by Ruigrok (2010) [10] and Reese (2007) [11].
One of the most popular methods for analyzing ultimate lateral load on the pile is the
method proposed by Blum (1932) [3] and Broms (1964, 1965) [1], [2]. Even though those
two methods can be used to determine ultimate lateral resistance of pile, they are different
in theoretical background in modeling lateral resistance of soil using simple geometrical
earth pressure distribution. As a result, results of calculations may be incorrect and not
CE19-1
accurate enough. In addition, Blum's method does not use input parameter of undrained
shear strength in the calculation such that its modeling does not follow the actual situation
when applying for the analysis case of cohesive soils.
At present, the analytical tools are more advanced that those in the past. The finite
element method has become popular in analyzing ultimate load resistance of pile. Research
works by Chaudry (1994) [8], Klar (2008) [4], and Zhang (2011) [5] were based on the
finite element analyses in calculations of pile under lateral load. However, their results
were not presented in terms of dimensionless chart between ultimate load and length or the
graph of failure envelope. One of examples of failure envelope studies include the works
by Ukritchon et al. (1998) [7] involving with limit state of strip footing, not pile.
The above mentioned works did not consider the combined loading of horizontal force
and moment. In contrast, Ukritchon (1998) [9] and Huang (2007) [6] applied finite element
limit analyses in determining the curve of failure envelope for the lateral force and moment
of embedded wall. The characteristics of failure envelope for different types of loadings
are shown in Figure 1b. Their results were based on the modeling of wall as plate element
and did not consider the effect of wall thickness. However, the embedded wall structures
have the finite thickness in actual conditions. Thus, the effect of wall thickness should be
incorporated into the study and it is the objective of this paper.
This research presents the dimensionless graph between ultimate lateral load and length
of embedded wall when subjected to horizontal force and moment. In addition, the results
of this research also include the failure envelope for the general case of embedded wall
acted by horizontal force and moment. The two dimensional finite element analyses,
PLAXIS (Brinkgreve, 2002) [12], are used in this study. In particular, the embedded walls
are modeled with solid elements with its finite thickness dimension as shown in Figure 1a,
not using plate element like previous research works. As a result, its modeling corresponds
to a more realistic case of embedded wall in the field. The next section explains important
modeling issues and analysis details of this research.
(a)
(b)
Figure 1. (a) Problem geometry of combined lateral load and moment, (b) Loading
conditions
CE19-2
Method of analysis
Model for analysis
This research uses the commercial finite element software, PLAXIS 2D (Brinkgreve,
2002) [12]. The two dimensional plane strain geometry is used to model the embedded
wall in the clay layer. The clay model is the Mohr-Coulomb material, where the undrained
shear strength profile is homogeneous and isotropic. The undrained condition of the clay is
modeled by the undrained type B, where state of stresses is effective stress, the stiffness
and Poisson's ratio are effective types. But, the undrained shear strength, su is total stress,
where the friction angle, = 0 and the dilatancy angle, = 0 in the analysis. The soil has
the total unit weight of , and the effective Young's modulus, E/su = 200. It should be
noted that the input value of soil unit weight does not have any effect to the limit load of
this problem since the analysis condition is undrained.
The embedded wall is modeled as elastic material of the non-porous type. Its properties
correspond to reinforced concrete wall, where the unit weight = 24 kN/m3, Poisson's ratio
= 0.21 and Young's modulus = 2.545 10 7 kPa. Because of elastic material modeling of
embedded wall, there is no failure of the wall in the analysis. This assumption is realistic in
actual design practice. The embedded wall must be designed to have enough thickness and
reinforcement in resisting shear and bending modes such that the failure of the system is
governed by the failure of the soil before the failure of the wall happens. The embedded
wall has the length of L, and thickness of D.
The boundary condition of this problem corresponds to a typical pattern used in finite
element analysis of geotechnical engineering. The bottom boundary plane is defined as
zero movements for both horizontal and vertical directions. The left and right boundary
planes are defined as zero horizontal movement, while it only vertical movement is
allowed, as shown in Figure 2.
The interaction between the clay and the wall is modeled using soil-structure interface.
These interface elements are modeled around both sides of the embedded wall and at its
base, as shown in Figure 2. The interface roughness between the clay and the wall is
controlled by Rinter, which is the soil-wall adhesion factor. In this analysis, Rinter has the
value of 0.67, which is the typical value for most soil-structure interface. Thus, according
to the Mohr-Coulomb material, the undrained shear strength for the interface element, ci =
0.67su. In addition, for embedded wall subjected to horizontal force and moment, there is a
possibility that separation can happen behind the interface between the clay and the wall.
Thus, the condition of no-tension of effective stress is also applied at those interface
elements.
The embedded wall is loaded at the top with the horizontal force, H and the moment,
M. The results of analyses are presented in terms of relationship between dimensionless
parameters of failure horizontal load, H/suD and embedded length ratio, L/D. The analyses
consider several ratios of L/D, ranging from 5-80. The larger value of L/D, the more
slender of the embedded wall. For each case of analysis, the thickness of the wall, D is
changed while the length of the wall remains constant, giving rise to different values of
L/D.
CE19-3
(a)
(b)
Figure 3. Typical mesh used in the finite element analysis with 15 nodes and 12 stress
points
Results
According to the modeling section of embedded wall as described earlier, results of present
study are compared with previous research works for different aspects of analyses as
follows.
CE19-4
Figure 4. Problem geometry of pile in Bromss (1964, 1965) [1], [2] model
(a)
(b)
CE19-5
(c)
(d)
Figure 5. Comparison of ultimate lateral resistance between the finite element analysis
and Broms (1965) [2], (a) e/D = 0, (b) e/D = 1, (c) e/D = 8, (d) e/D = 16
Purely Lateral load or Purely Applied Moment
Figures 6-13 show examples of predicted failure mechanisms from finite element
analyses. Figure 6-9 correspond to the case of purely lateral load of embedded wall, while
Figure 10-13 correspond to the case of purely applied moment of embedded wall. For each
case, the failure results include deformed mesh, total increment vector, and incremental
shear strain contour. Comparisons are made for three cases of wall thickness ratio, L/D = 5,
40, and 80. The case of L/D = 5 corresponds to a relatively thick wall, while the case of
L/D = 80 corresponds to a relatively slender wall. For purely horizontal load (Figure 6-9),
the failure mechanism of the embedded wall happens such that the wall rotates about some
point near its tip without translation movement of the wall. Near the ground surface, the
front side fails in the passive state condition, while the back side fails in the active mode.
On the other hand, for purely applied moment (Figure 10-13), the embedded wall fails by
wall rotation at about the mid point of the wall without translation movement of the wall.
The failure zone of passive and active modes of purely applied moment is much smaller
than that of purely horizontal load.
Figure 6. Deformed mesh for purely lateral load, where L/D = 5, 40, 80
CE19-6
Figure 7. Total increment vectors for purely lateral load, where L/D = 5, 40, 80
Figure 8. Incremental shear contours for purely lateral load, where L/D = 5, 40, 80
Figure 9. Plastic points of for purely lateral load, where L/D = 5, 40, 80
Figure 10. Deformed mesh for purely applied moment, where L/D = 5, 40, 80
Figure 11. Total increment vectors for purely applied moment, where L/D = 5, 40, 80
CE19-7
Figure 12. Incremental shear strain contours for purely applied moment, where L/D = 5,
40, 80
Figure 13. Plastic points for purely applied moment, where L/D = 5, 40, 80
Figure 14 shows the results of purely horizontal ultimate load, H/suD or purely
ultimate moment, M/suLD for the case of plane strain condition without considering
scaling effect to the actual pile geometry. It can be seen that the selected dimensionless
terms, H/suD and M/suLD give the best result, yielding the linear relationship between
those values and L/D. Thus, mathematical equation for predicting those values has much
simpler form because of linear relationship.
(a)
(b)
Figure 14. Normalized limit state solutions, (a) purely lateral load, (b) purely applied
moment
CE19-8
Figure 15. Deformed mesh of combined lateral load and moment, where L/D = 5, 40, 80,
and M/HL = 1/30
Figure 16. Total increment vectors of combined lateral load and moment,
where L/D = 5, 40, 80, and M/HL = 1/30
Figure 17. Incremental shear strain contour of combined lateral load and moment,
where L/D = 5, 40, 80, and M/HL = 1/30
direction, labeled as I in the first quadrant. The second case corresponds to the case where
lateral load and moment produce overturning to the opposite direction, labeled as II in the
second quadrant. The remaining of the graph in the third and fourth quadrants is obtained
from the symmetry of the problem. In particular, the result of first quadrant is equal to that
of the third quadrant, while that of the fourth quadrant is equal to that of the second one.
The failure envelope is plotted as a function of ultimate lateral resistance, H/suD and
ultimate moment resistance, M/suLD, as shown in Figure 19. Figure 19a, 19b, and 19c
show the case of embedded wall ratios, L/D = 5, 40, and 80, while Figure 19d compares
all failure envelopes for different values of L/D. It can be seen that each failure envelope
has the form of elliptical shape, which is also rotated about 3/4 from the positive
horizontal axis. However, the rotated ellipse is not symmetrical at its rotated major and
minor axes. The non-symmetry of the ellipse happens at both ends of the major axis,
resulting in distorted form of rotated ellipse. However, it can be seen that the distorted and
rotated ellipse does hold convexity condition, where the classical concept of failure
envelope is still valid. The size of rotated ellipse is controlled by the ratio of L/D. The
higher the ratio of L/D, the larger the size of the rotated ellipse.
(a)
(b)
(c)
(d)
Figure 19. Failure envelope for combined lateral load and moment, (a) L/D = 5, (b) L/D =
40, (c) L/D = 80, (d) Comparisons for all ratios of L/D = 5, 20, 40, 60, 80
CE19-10
Figure 20. Comparison of failure envelope between the present study and Ukritchon (1998)
Conclusions
This research presents the use of two dimensional plane strain finite element model in
analyzing ultimate state of embedded wall subjected to combined horizontal load and
moment. Unlike previous research works in the past, the present study considers the effect
of wall thickness, which corresponds to a more realistic case in the field. The results of
analyses are presented in terms of dimensionless variables, namely 1) embedded length
thickness ratio, L/D; 2) normalized ultimate lateral resistance, H/suD; and 3) normalized
ultimate moment resistance, M/suLD. The ratio of L/D is modeled to have different ranges
from 5-80. The studies include analysis of the limit state for purely lateral load, purely
applied moment, and combined lateral and moment. The studied results can be used in
analyzing and designing embedded wall for plane strain condition or actual pile geometry.
However, the latter case requires simple scaling from plane strain solutions to obtain the
limit state of actual pile. Comparisons of the latter case show that the ultimate lateral
resistance scaled from the plane strain condition is much smaller than that of Broms (1965)
[2], which indicates that the results give much conservative calculations. In addition, the
failure envelope of H-M has the form of rotated ellipse with distortion at both ends. The
CE19-11
shape pattern of the present study is similar to that of Ukritchon (1998) [7], but the latter
has smaller size due to different modeling of no-tension condition at soil-structure
interface.
Acknowledgment
The first author would like to thank the department of civil engineering, Chulalongkorn
University for financial support of his graduate there, where he received the-100-year
university celebration graduate research grant from the department. This allows him to
pursue the master study for his interest in course works and research in geotechnical
engineering, Chulalongkorn University.
References
[1] B.B. Broms, Design of laterally loaded piles, Journal of the soil mechanics and
foundation, division 91 (3), 77-99, 1965.
[2] B.B. Broms, Lateral resistance of piles in cohesive soils, Journal of the soil
mechanics and foundation, division 90 (2), 27-63, 1964.
[3] H. Blum, Wirtschaftliche dalbenformen und deren berechnung, Bautechnik, Heft 5,
1932.
[4] A. Klar, M. F. Randolph, Upper-bound and load-displacement solution for laterally
loaded piles in clays based on energy minimization, Gotechnique 58, N0. 10, 815820, 2008.
[5] L. Zhang, Nonlinear analysis of laterally loaded rigid piles in cohesive soil,
International journal for numerical and analytical method in geomechanics 2013,
37:201-220, 2011.
[6] M. Huang, Q. Huang, Ultimate lateral resistance of sheet pile walls by numerical
lower bound analysis, Chinese Journal of Geotechnical Engineering 2007, Vol. 29,
Issue (7), 988-994, 2007.
[7] B. Ukritchon, A.J. Whittle, S.W. Sloan, Undrained limit analysis for combined
loading of strip footings on clay, Journal of Geotechnical and Geoenvironmental
Engineering, ASCE, 124(1): 265276, 1998.
[8] A.R. Chaudhry. Static pile-soil-pile Interaction in Offshore pile groups. Thesis (PhD),
University of Oxford, England, 1994.
[9] B. Ukritchon. Application of Numerical limit analyses for Undrained stability
problems in clay. Thesis (PhD), Massachusetts Institute of technology, USA, 1998.
[10] J.A.T. Ruigrok. Laterally loaded piles models and measurements. Thesis (PhD), Delft
University of Technology, Netherlands, 2010.
[11] L.C. Reese, W.F. Van Impe, Single piles and pile groups under lateral loading,
Taylor & Francis Group plc, London, UK, 2007.
[12] R.B.J. Brinkgreve, et al., Plaxis 2D Version 8 Manual, A.A. Balkema Publishers,
Netherlands, 2002.
CE19-12