This catalog presents a selection of the Sediver composite Line Post insulators answering the needs of North-American
customers in term of standards (ANSI), current practices and environmental conditions. ANSI standard C29.17 sets the
basic and minimum requirements for this type of insulator. Sediver composite insulators meet and exceed the performance
requirements of ANSI standards.
Sediver today
The SEVES group is a world leader in the power insulator industry, specialized in composite, toughened
glass and porcelain insulators for high voltage transmission lines and substations.
Sediver is part of the Seves group and has been specialized for the last 60 years in the field of high
voltage toughened glass and polymer insulation. More recently, composite surge arresters have been
added to our product range.
Quality of products
Each factory quality organization is coordinated through a centralized Quality Department who acts as the clients
representative in determining and assuring full compliance of the manufactured insulators with the highest standards.
Each quality department has absolute authority to ensure that the overall quality policy is enforced and respected at all
levels of operations.
Materials
Housing material
Sediver line post insulators are available either with EPDM
or with silicone rubber housing.
EPDM compound has been specially formulated to
provide optimum weathering and electrical properties for
all operating conditions.
Sediver has more than 30 years of excellent field
experience with EPDM insulators over a wide range of
pollution levels.
Silicone compound provides excellent hydrophobic and
recovery characteristics which limit leakage current and
arcing in polluted or seacoast environments.
Both Sediver rubber formulations are the result of
extensive research and testing programs.
Galvanized end fittings designed to reduced the E-field and provide a large
surface rubber bonding
Grading rings
Line voltage
2.5"
serie 30
(1)
230 kV
X(1)
345 kV
500 kV
X
X
1.75 (44mm)
SERIES 20
End fittings
Line end
13/16"
(20.6mm)
K*
V*
T
*to be used with trunnion clamps as per ANSI C29.7
Pole end
Trunnion clamps
3/4"- 10UNC
or
7/8"- 9UNC
3.3"(85mm)
Catalog N
ACTS 45-25-57
0.25-0.57
ACTS 45-5-106
0.50-1.06
ACTS 106-150
1.00-1.50
Bases type G
Horizontal Gain
GB-12
Vertical Gain
V8-08
Mounting studs
A
A
B
A
C
Base
Stud
Ref.
In
mm
In
mm
In
mm
SS-1
1.8
46
1.56
40
0.75
19
22
In
mm
In
mm
In
mm
In
mm
SS-2
2.0
51
1.56
40
0.88
GB-12
9.5
241
12
305
0.94
23.8
SW-1
7.56
192
4.0
102
0.75
19
VB-08
127
76
13.1
333
0.69
17.5
SW-2
8.07
205
4.0
102
0.88
22
1.75(44mm)
SERIES 20
x
1.5"
(38.5mm)
Rev 8-10
x
5
5.78"
( 147 mm)
NPVN20
Typical
Line
Voltage
NPKN20
Sediver
Catalog
Designation
Number
of
Sheds
Line Post
Spacing
X
Inches
(mm)
Inches
(mm)
20.6
522
20.6
522
22.0
558
22.0
560
22.0
560
23.5
596
25.1
637
25.1
637
26.5
673
26.6
676
26.6
676
28.0
711
28.1
714
28.1
714
29.5
750
31.1
791
31.1
791
32.5
826
32.7
830
32.7
830
34.1
865
37.9
962
37.9
962
37.9
962
42.7
1085
42.7
1085
42.7
1085
52.4
1331
52.4
1331
52.4
1331
57.2
1453
57.2
1453
57.2
1453
62.0
1576
62.0
1576
62.0
1576
71.7
1822
71.7
1822
71.7
1822
76.5
1944
76.5
1944
76.5
1944
14.3
363
14.3
363
14.3
363
15.8
401
15.8
401
15.8
401
18.8
478
18.8
478
18.8
478
20.4
517
20.4
517
20.4
517
21.9
555
21.9
555
21.9
555
24.9
632
24.9
632
24.9
632
26.4
671
26.4
671
26.4
671
11
12
13
15
Dry Arcing
Distance*
Inches
(mm)
Leakage
Distance
16
NPKG20
Low
Frequency
Flashover *
Critical
Impulse
Flashover *
Dry
kV
Wet
kV
Pos.
kV
Neg.
kV
165
120
255
395
165
120
255
395
165
120
255
395
180
135
275
425
180
135
275
425
180
135
275
425
210
160
315
490
210
160
315
490
210
160
315
490
225
175
335
515
225
175
335
515
225
175
335
515
240
190
355
545
240
190
355
545
240
190
355
545
265
215
395
590
265
215
395
590
265
215
395
590
280
230
435
605
280
230
435
605
280
230
435
605
Max. Design
Cantilever
Load
Approx.
Net Wt
Lbs
(kN)
Lbs.
(kg)
1450
6.5
1450
6.5
1360
6
1350
6
1350
6
1270
5.7
1190
5.3
1190
5.3
1130
5
1120
5
1120
5
1070
4.8
1060
4.7
1060
4.7
1010
4.5
960
4.3
960
4.3
920
4.1
910
4.1
910
4.1
880
3.9
11
5
11
5
19
8.6
12
5.3
12
5.3
19
8.8
13
5.8
13
5.8
21
9.4
13
6.1
13
6.1
21
9.6
14
6.4
14
6.4
22
9.9
15
6.9
15
6.9
23
10.5
16
7.2
16
7.2
24
10.7
Stud
Ref.
SS-1
or
SW-1
3/4"
SS-2
or
SW-2
7/8"
Tests complying with ANSI C29.17. Table shows typical models. Other dimensions or fittings combinations are available on request.
STL: Clamp top 5,000 Lbs (22 kN) - Tongue 10,000 Lbs (44 kN)
N
ANSI
Standard
P1 K2 G3
20
1-Pole end
2-Line end
3-Base type: G-Gain, N-No base
XH9
Shed
profile
012
Number
of sheds
S
Housing material
S - Silicone
E - EPDM
0
Number of
grading rings
2.5 (63mm)
SERIES 30
End fittings
Line end
1.5"
(38mm)
4" (101.6mm)
1"
(25.4mm)
1.7"
(43mm)
13/16"
(20.6mm)
K(*)
V(*)
0.75"
(19mm)
0.8"
(20.4mm)
1.3"
(33mm)
3" (76mm)
0.75"
(19mm)
0.67"
(17mm)
3.7" (95mm)
1.7"
(43mm)
3.7"
(95mm)
0.67"
(17mm)
Pole end
6.1" (155mm)
5" BCD
(127mm)
.94"
(24mm)
5" BCD
(127mm)
0.8"
(20.4mm)
1.3"
(33mm)
6.1" (155mm)
2"
(51mm)
11/16" (17.5mm)
11/16" (17.5mm)
B(**)
Bases
Bendable gain
BG01 or BG55
G or L
Rigid gain
EG127
G D1
D1
Rigid flat
EF127
F
Bendable flat
BF02
F
D1
D2
1
2
Type
G
L
F
A
Base
5XD1
B A
BG01
12
EG127
12
BG55
B A
D2
B
mm
1XD2
D2
A
In
Hinged
EC45
A D2
In
C
mm
In
1
mm
D1
D2 (Slot)
In
mm
In
mm
In
mm
In
mm
305
14
356
178
0.94
305
10
254
178
0.94
23.8
0.94x1.5
23.8x38
23.8
0.94x1.38
14
356
24
610
229
24x35
0.94
23.8
0.94x1.5
23.8x38
BF02
10
254
12
305
EF127
10
254
12
305
203
0.94
23.8
1x3
25.4x76
203
0.83
21
0.86x1.28
21.8x32
EC45
101.6
127
0.81x1.31
20.6x33.3
2.5(63mm)
SERIES 30
6.8"( 173mm)
12
1.5"(38.5mm)
Typical
Line
Voltage
Sediver
Catalog
Designation
Number
of
Sheds
SEDNBSG30XH 016 S0
16
SEDNBSG30XH 019 S0
19
69-115 kV
SEDNBSG30XH 023 S0
23
115 kV
SEDNBSG30XH 025 S0
25
115-138
kV
SEDNBSG30XH 029 S0
29
138 kV
SEDNBSG30XH 034 S0
34
SEDNBSG30XH 039 S0
39
SEDNBSG30XH 043 S0
43
SEDNBSG30XH 047 S1
47
SEDNBSG30XH 051 S1
51
SEDNBSG30XH 055 S1
55
SEDNBSG30XH 058 S1
58
69 kV
161 kV
with grading
ring*
230 kV
Line Post
Spacing
X
Leakage
Distance
Inches
(mm)
Dry Arcing
Distance*
Inches
(mm)
Inches
(mm)
34.3
77
25.8
871
1958
657
38.7
92
30.4
984
2331
772
44.6
111
36.5
1134
2829
926
47.6
121
39.5
1210
3078
1003
53.5
141
45.6
1360
3575
1157
61.0
165
53.1
1549
4198
1350
68.4
190
60.7
1737
4820
1542
74.3
209
66.8
1887
5318
1696
80.2
229
68.4
2038
5815
1737
86.2
249
74.4
2189
6313
1891
92.1
268
80.5
2339
6811
2045
96.5
283
85.0
2452
7184
2160
Low
Frequency
Flashover *
Max. Design
Cantilever
Load
Critical
Impulse
Flashover *
Dry
kV
Wet
kV
Pos.
kV
Neg.
kV
275
225
425
595
320
265
495
670
375
315
585
760
400
335
635
800
455
385
725
885
520
445
835
985
585
500
950
1080
635
545
1040
1155
645
555
1060
1175
695
600
1150
1245
745
640
1240
1315
785
670
1305
1370
Approx.
Net Wt
Lbs
(kN)
Lbs.
(kg)
2630
56
11.7
25.6
2260
60
10.1
27.1
1900
64
8.5
29.0
1770
66
7.9
30.0
1540
71
6.8
32.0
1330
76
5.9
34.5
1170
82
5.2
37.0
1070
86
4.8
39.0
990
96
4.4
43.4
920
100
4.1
45.4
850
104
3.8
47.3
810
108
3.6
48.8
Tests complying with ANSI C29.17. Table shows typical models. Higher voltages and other dimensions or fittings combinations are available on request.
STL: Clamp top 5,000 Lbs (22 kN) - Other fittings 15,000 Lbs (67 kN).
*When grading rings are included in the designation, the electrical values and dry arcing distances are given accordingly.
N
ANSI
Standard
P1 K2 G3
End fitting and base
2-Line end
30
XH
034
Shed
profile
Number
of sheds
Housing material
S - Silicone
Number of
grading rings
1-Pole end
E - EPDM
3.0(76 mm)
SERIES 35
End fittings
1.7"
(43mm)
0.8"
(20.4mm)
1.3"
(33mm)
( 6.7" 170mm)
5" BCD
(127mm)
5/8" 11UNC
13/16"
(20.6mm)
K(*)
1.77"
(45mm)
Line end
4" (101.6mm)
3"(76mm)
1"
(25.4mm)
Pole end
1.7"
(43mm)
1.37"
(35mm)
5" BCD
(127mm)
0.8"
(20.4mm)
1.3"
(33mm)
5.5"
(140mm)
1.77"
(45mm)
( 6.7" 170mm)
5.5" (140mm)
2.95"
(75mm)
5/8" 11UNC
B(**)
Bases
Bendable gain
G
Bendable flat
F
Hinged
A
D2
D1
D1
A
B A
B A
D2
D3
10
Type
Base
G
F
A
In
mm
BG40
14
356
BF40
13
EC45
D2
D1
In
mm
In
mm
In
mm
330
16
406
229
10
254
101.6
127
D2 (slot)
In
mm
In
mm
1.06
26.9
1.06x2.56 26.9x65
1.06
26.9
1.06x2.56 26.9x65
0.81x1.31 20.6x33.3
D3 (slot)
In
mm
0.94x2.52 23.8x64
3.0(76 mm)
SERIES 35
6.9"(176mm)
1.5"(38.5mm)
12
Typical
Line
Voltage
Sediver
Catalog
Designation
Number
of
Sheds
69/115 kV
SEDNBSG35 XI 021 S0
21
115 kV
SEDNBSG35 XI 023 S0
23
115/138 kV
SEDNBSG35 XI 027 S0
27
138 kV
SEDNBSG35 XI 032 S0
32
SEDNBSG35 XI 037 S0
37
SEDNBSG35 XI0 41 S0
41
SEDNBSG35 XI 044 S0
44
SEDNBSG35 XI 048 S0
48
SEDNBSG35 XI 052 S0
52
SEDNBSG35 XI 055 S0
55
SEDNBSG35 XI 058 S0
58
Line Post
Spacing
X
161 kV
230 kV
Inches
(mm)
Leakage
Distance
Inches
(mm)
Dry Arcing
Distance*
Inches
(mm)
45.2
99
33.3
1148
2518
846
48.2
108
36.3
1224
2756
923
54.1
127
42.4
1374
3232
1077
61.5
151
50.0
1563
3827
1270
68.9
174
57.6
1751
4422
1462
74.9
193
63.6
1902
4898
1616
79.3
207
68.2
2015
5255
1732
85.2
226
74.2
2165
5731
1886
91.2
244
80.3
2316
6207
2040
95.6
258
84.8
2429
6564
2155
100.1
272
89.4
2542
6921
2271
Low
Frequency
Flashover *
Critical
Impulse
Flashover *
Dry
kV
Wet
kV
Pos.
kV
Neg.
kV
345
285
540
710
370
310
585
755
425
360
675
840
490
420
790
945
555
475
905
1040
605
520
995
1120
645
555
1060
1175
695
595
1150
1245
745
640
1235
1315
780
670
1300
1365
820
700
1370
1415
Maximum
Design
Cantilever Load
Approx.
Net Wt
Lbs
(kN)
Lbs.
(kg)
2920
56
13
25.2
2740
58
12.2
26.4
2430
63
10.8
28.7
2140
70
9.5
31.7
1910
76
8.5
34.6
1760
81
7.8
36.9
1660
85
7.4
38.6
1550
90
6.9
41.0
1450
95
6.4
43.3
1380
99
6.1
45.1
1330
103
5.9
46.8
Tests complying with ANSI C29.17. Table shows typical models. Higher voltages and other dimensions or fittings combinations are available on request.
STL: Clamp top 5,000 Lbs (22 kN) - Other fittings 15,000 Lbs (67 kN).
*When grading rings are included in the designation, the electrical values and dry arcing distances are given accordingly.
Sediver
design
ANSI
Standard
P1 K2 G3
35
XI
032
Shed
profile
Number
of sheds
Housing material
S - Silicone
E - EPDM
Number of
grading rings
1-Pole end
2-Line end
3-Base type: G-Gain, F-Flat, A-Hinged, N-No base
11
3.5(88 mm)
SERIES 40
End fittings
1.7"
(43mm)
0.8"
(20.4mm)
1.3"
(33mm)
( 6.7" 170mm)
5" BCD
(127mm)
5/8" 11UNC
13/16"
(20.6mm)
K(*)
1.77"
(45mm)
Line end
4" (101.6mm)
3"(76mm)
1"
(25.4mm)
Pole end
1.7"
(43mm)
1.37"
(35mm)
5" BCD
(127mm)
0.8"
(20.4mm)
1.3"
(33mm)
5.5"
(140mm)
1.77"
(45mm)
( 6.7" 170mm)
5.5" (140mm)
2.95"
(75mm)
5/8" 11UNC
B(**)
Bases
Bendable gain
G
Bendable flat
F
Hinged
A
D2
D1
D1
A
B A
B A
D2
D3
12
Type
Base
G
F
A
In
mm
BG40
14
356
BF40
13
EC45
D2
D1
In
mm
In
mm
In
mm
330
16
406
229
10
254
101.6
127
D2 (slot)
In
mm
In
mm
1.06
26.9
1.06x2.56 26.9x65
1.06
26.9
1.06x2.56 26.9x65
0.81x1.31 20.6x33.3
D3 (slot)
In
mm
0.94x2.52 23.8x64
3.5(88 mm)
SERIES 40
7"(178mm)
12
1.5"(38.5mm)
X
Typical
Line
Voltage
Sediver
Catalog
Designation
115 kV
Number
of
Sheds
SEDNBSG40XV023S0
115-138 kV SEDNBSG40XV027S0
138 kV
23
27
SEDNBSG40XV032S0
32
SEDNBSG40XV037S0
37
161 kV
SEDNBSG40XV041S0
41
SEDNBSG40XV045S0
45
SEDNBSG40XV049S0
49
SEDNBSG40XV056S0
56
345 kV
SEDNBSG40XV069S1
69
500 kV
SEDNBSG40XV085S2
85
230 kV
Line Post
Spacing
X
Inches
(mm)
Leakage
Distance
Dry Arcing
Distance*
Inches
(mm)
Inches
(mm)
48.1
96
36.4
1221
2428
925
54.0
112
42.5
1371
2852
1079
61.4
133
50.1
1560
3382
1272
68.8
154
57.6
1748
3912
1464
74.8
171
63.7
1900
4336
1618
80.7
187
69.8
2049
4760
1772
86.6
204
75.8
2200
5183
1926
with
grading
ring*
97
233
86.4
2463
5925
2196
116.3
288
104.6
2953
7303
2657
140.0
354
121.8
3556
8998
3094
Low
Frequency
Flashover *
Critical
Impulse
Flashover *
Dry
kV
Wet
kV
Pos.
kV
Neg.
kV
370
310
585
755
425
360
680
420
790
945
555
475
905
1045
520
995
Approx.
Net Wt
Lbs
(kN)
Lbs.
(kg)
4110
110
845
490
610
Max. Design
Cantilever
Load
1120
660
565
1085
1190
710
610
1170
1265
795
680
1325
1385
940
800
1580
1580
1075
915
1760
1760
18.3
50
3660
116
16.3
52.8
3230
124
14.4
56.4
2890
132
12.8
60
2620
139
11.6
62.9
2410
145
10.7
65.7
2220
151
9.9
68.6
1960
162
8.8
73.6
1660
188
7.4
85.4
1420
219
6.3
99.3
Tests complying with ANSI C29.17 . Table shows typical models. Higher voltages and other dimensions or fittings combinations are available on request.
STL: Clamp top 5,000 Lbs (22 kN) - Other fittings 15,000 Lbs (67 kN).
*When grading rings are included in the designation, the electrical values and dry arcing distances are given accordingly.
Sediver
design
ANSI
Standard
P1 K2 G3
40
XV
032
Shed
profile
Number
of sheds
Housing material
S - Silicone
E - EPDM
Number of
grading rings
1-Pole end
2-Line end
3-Base type: G-Gain, F-Flat, A-Hinged, N-No base
Packing
Sediver composite insulators are packed in wooden crates.
The inner part of the crate is lined with a plastic film to
avoid a direct contact of the polymeric housing with
the wood. Within the crate, each layer of insulators is
supported by wooden separators to avoid damage of the
insulator sheds, either from the weight of the insulators
stacked above or during shipping.
13
L
L
50- 60
50- 60
V
50- 60
14
Line Post
Designation
Brace
Designation
NBSG30XH25S0
NEE120XF039S0
NBSG30XH29S0
NEE120XF045S0
NBSG30XH34S0
NEE120XF055S0
NBSG30XH39S0
NEE120XF065S1
Typical
Line
Voltage
115 kV
with
grading
ring*
161 kV
BLPG 161 3014 0002 S1
NBSG30XH43S0
NEE120XF071S1
NBSG30XH51S0
NEE120XF085S1
NBSG30XH55S0
NEE120XF091S1
Line Post
Designation
Brace
Designation
230 kV
In
mm
In
mm
In
mm
In
mm
47.6
1209
53,5
1361
61.0
1549
68.4
53.9
1370
60.4
1535
71.2
1809
82.1
55.7
1416
60.1
1528
68.9
1750
79.2
2
51
2
51
2
51
2
51
74.3
1887
86.2
2189
92.1
2339
2
51
2
51
2
51
88.6
2250
103.7
2634
110.2
2799
83.6
2123
95.5
2426
99.9
2538
Low
Frequency
Flashover*
Dry
kV
Wet
kV
Critical
Impulse
Flashover *
Pos.
kV
Neg.
kV
400
335
635
800
455
385
725
880
520
445
835
980
505
430
810
960
555
475
900
1040
655
560
1075
1185
690
590
1140
1240
Maximum
Approx.
Vertical
Net Wt
Load (1)
Lbs
(kN)
Lbs.
(kg)
11250
50
11250
50
9000
40
6750
80
36
86
39
92
42
106
30
48
5625
25
4050
18
3375
15
111
50
122
55
127
58
Sediver
Catalog
Designation
PHVF 161 3014 0001 S1
NCSA30XH39S0 NEE120XF057S1
NCSA30XH43S0 NEE120XF063S1
NCSA30XH47S0 NEE120XF069S1
NCSA30XH51S0 NEE120XF075S1
NCSA30XH55S0 NEE120XF079S1
NCSA30XH58S0 NEE120XF083S1
161 kV
with
grading
ring*
230 kV
In
mm
In
mm
In
mm
In
mm
70.3 73.4
1786 1865
76.4 79.9
1940 2030
82.4 86.4
2094 2195
88.5 92.9
2248 2360
94.6 97.2
2402 2470
99.1 101.6
2517 2580
68.7
1744
72.2
1835
80.2
2038
83.9
2130
86.2
2190
88.2
2240
22
559
22
559
28
711
28
711
30
762
30
762
In
mm
In
mm
In
mm
In
mm
Low
Frequency
Flashover *
Dry
kV
Wet
kV
Critical
Maximum
Approx.
Impulse
Vertical
Net Wt
Flashover *
Load (1)
Pos.
kV
Neg.
kV
510
435
820
970
555
475
900
1040
610
525
1000
1125
660
570
1085
1195
705
605
1170
1260
745
640
1235
1315
Lbs
(kN)
Lbs.
(kg)
11250
50
11250
50
11250
50
11250
50
11250
50
11250
50
80
36
85
39
90
41
95
43
100
45
104
47
Sediver
Catalog
Designation
Line Post
Designation
Brace
Designation
with
grading
ring*
Low
Frequency
Flashover *
Dry
kV
Wet
kV
Critical
Maximum
Approx.
Impulse
Vertical
Net Wt
(1)
Flashover *
Load
Pos.
kV
Neg.
kV
835
715
1400
1440
1020
870
1730
1690
Lbs
(kN)
Lbs.
(kg)
10125
45
11250
50
161
73
251
114
Test complying with ANSI C29.17 . Table shows typical models. Other dimension of fittings combinations are available upon request.
(*) When grading rings are included in the designation, the electrical values are given accordingly.
0.94"
(1) Maximum vertical load: with no longitudal or transversal stresses.
(24mm)
Application curves taking into account tridimensional loading are available upon request.
All assemblies above are equipped with two straight shackles, one at the tower end
and one connecting the brace to the line post.
Adjustable extension links or turnbuckles can be offered upon request in order to
match different vertical distances on the tower as well as customized design.
0.79"
(20mm)
4.45"
(113mm)
15
T&D Committee
Sedivers
experts are
active in
IEEE Guide for Braced Insulator Assemblies for Overhead Transmission Lines 60 kV and greater
IEEE TF15.09.09.07 (E. DEL BELLO) IEEE Transactions on Power Delivery, Vol.23 N2, April 2008
p.785-791
Determination of the brittle fracture process of field failed HV insulators C. de TOURREIL ; G.
THEVENET ; E. BROCARD ; N. SIAMPIRINGUE ; N. PICHON XIVth ISH , 2005 Paper D-28
Use of corona rings to control the electrical field along transmission line composite insulators
CIGRE WG B2-03 (E. BROCARD ) CIGRE TECHNICAL BROCHURE, 2005 N 284
WG Insulator
contamination
Guide for the evaluation of composite line post insulators subjected to combined mechanical load
/ Guide pour lvaluation des consoles isolantes composites soumises une combinaison de charges
mcaniques CIGRE WG 22-03 (E. BROCARD) ELECTRA, 2002, N 203
WG Insulator strength
Composite Insulator Handling guide CIGRE WG 22-03 (E. BROCARD ) CIGRE TECHNICAL
BROCHURE, April 2001, N 184
WG Application of non
ceramic insulators
Brittle fracture of composite insulators : the new explanation and a field case study
C. DE TOURREIL, L. PARGAMIN, G.THEVENET, S. PRAT, N. SIAMPIRINGUE , ISH, 2001, Paper 5-25
ESMOL
New compact composite insulation for environmental economic and safety considerations
D. DUMORA, 2001 WORLD INSULATOR CONGRESS AND EXHIBITION, Shanghai Nov. 18-21, 2001
Non destructive techniques for the evaluation of the integrity of composite insulators
J.M. GEORGE, INTERNATIONAL SYMPOSIUM ON MODERN INSULATOR TECHNOLOGIES, Coral Gables
Florida, Nov. 16-19, 1997
Studies of the long term performance of composite insulators and of the representativity of ageing
tests G. RIQUEL, JM FOURMIGUE, D. DE DECKER, R. JOULIE, R. PARRAUD, CIGRE 1996, Paper 33304
Review of in service diagnostic testing of composite insulators / Revue des techniques de diagnostic
en service pour isolateurs composites CIGRE WG 22-03, ELECTRA, 1996, N 169
Rating of composite suspension insulators related to the long term mechanical strength of rods
L. PARIS, L. PARGAMIN, D. DUMORA, R. PARRAUD, IEEE Transactions on Power Delivery, Vol.9 n4
October 1994 p.2055-2063
Mechanical behavior of flexurally stressed composite insulators D. DUMORA, D. FELDMANN, M.
GAUDRY, IEEE POWER DELIVERY, 1990 Vol. 5 n2 p.1066-1073
Natural and artificial weathering of EPDM compounds used in outdoor high voltage insulation C.
AUBIN, C. HOUDRET, R. MAILFERT, L. PARGAMIN, IEEE ELECTRICAL INSULATION, 1981, N 4
Composite insulators for lines 220 kV and above L. PARGAMIN, J. HUC, IEE CONFERENCE
PUBLICATION, 1979, N 176
Effects of the superposition of electric, mechanical and environmental stresses on the fatigue
behavior of composite insulating materials R. MAILFERT, J. THORIS, D. RIVIERE, L. PARGAMIN,
CIGRE, 1978, Paper 15-10
Catalogs
172 Merizzi,
Ville St-Laurent, Quebec, Canada H4T 1S4
Tel. +1.514.739.3385 - Fax +1.514.739.3669
info@seves.ca - www.seves.com
Behaviour of fiber reinforced plastics in HV insulators and fiber matrix bonding in composites:
testing and measurements by a pointe-plan needle test L. PARGAMIN, R. MAILFERT, IEEE, 1976,
Paper A 77 025-0