Professional Documents
Culture Documents
Catalogue 1YMA699050-en
APPLICATION
The current transformers types IMW, IMP, IMS, ISW, INSOA are
intended for supplying measuring instruments and protective circuits
of electrical power devices with maximum operating voltage 0,72 kV
and frequency 50 Hz. These current transformers are manufactured
for secondary currents 1 A or 5 A.
The current transformers types IMR 0, IMR 1, IMR 2 are intended for
supplying measuring instruments and protective circuits of electrical
power devices with maximum operating voltage 0,72 kV and
frequency 50 Hz, particularly for fuse disconnectors of series SLM
and SRE Slim Line , size 00, 1, 2 and 3.
OPERATING CONDITIONS
WARRANTY
DESIGN
The factory warranty is twenty four months since the day of putting
the apparatus into operation, but not longer than thirty six months
since the date of purchase.
TECHNICAL DATA
Type
Rated
power
Ipn
Secondary
current
Isn
VA
Primary
current
5
5; 7,5;
10; 15
20
5
1; 2; 3; 5;
10; 15;
20; 25
30; 50
75
100
150
IMW
200
250
300
Sn
5; 7,5;
10; 15
20
5; 7,5;
10
1 or 5
Rated current
Security
short-time
dynamic
Class of factor for
thermal
(peak)
apparat.
accuracy
Ith
Idyn
FS
kA
0,2
10
0,5 or 1
1
0,2
10
0,5 or 1
5; 7,5;
10; 15
20
5; 7,5
kV
Rated test
voltage
Weight Spacing of
(about) cerminals
Up
kV
kg
Current
terminals
mm
102
or
108
M6
or
M8
108
M8
1
0,5
10
5
10
5; 7,5;
10; 15
15
5
kA
Maximum
permissible
voltage of
transformer
Um
10
60 x lpn
150 x lpn
0,72
0,8
5
0,2
0,5 or 1
1
0,2
5; 7,5; 10;
0,5 or 1
15; 20
10
5
Note: The versions of current transformer type IMW with secondary winding parameters: 5 VA, class 0,2; 10 VA, class 0,5; 15 VA, class 1 areprefered.
2
ABB
102 or 108
114 or 127
Rated power
Type
Rated
ratio
A/A
IMPa
IMPb
100/5
100/1
150/5
150/1
200/5
200/1
250/5
250/1
300/5
300/1
150/5
150/1
200/5
200/1
250/5
250/1
300/5
300/1
400/5
400/1
Sn
class 0,2
class 0,5
class 1
VA
VA
VA
2,5
5
7,5
10
5
7,5
10
5; 7,5;
10; 15
5; 7,5;
10; 15
5 *
7,5
5; 7,5;
10; 15;
20
5; 7,5;
10; 15;
20
5; 7,5;
10; 15;
20
2,5
5
7,5
10
5
7,5
10
*
5; 7,5;
10; 15
5 *
7,5
5; 7,5;
10; 15;
20
FS
dynamic
(peak)
Idyn
kA
kA
kV
kV
kV
kg
60 x lpn
150 x lpn
0,72
10 x 20
0,8
60 x lpn
150 x lpn
0,72
10 x 30
0,5
Weight
(about)
Up
Maximal
dimens.
of cross-section
of a bus
Rated test
voltage
10
10
5; 7,5;
10; 15
5; 7,5;
10; 15;
20
5; 7,5;
10; 15;
20
short-time
thermal
Ith
Maximum
permissible
voltage of
transformer
Um
Rated current
Supporting version
Type
Primary
current
Secondary
current
Ipn
Isn
Rated power
Sn
class 0,2 class 0,5 class 1
VA
VA
150
200
250
300
or
IMSa
400
600
5
7,5
10
500
Security
factor for
apparat.
5
7,5
10
15
5
7,5
10
15
VA
5
5
7,5
5
7,5
5
7,5
10
5
7,5
10
15
5
7,5
10
15
20
5
7,5
10
15
20
FS
Rated current
short-time
thermal
Ith
dynamic
(peak)
Idyn
Maximum
permissible
voltage of
transformer
Um
kA
kA
kV
kV
kg
60 x lpn
150 x lpn
0,72
0,45
Rated test
voltage
Weight
(about)
Up
ABB
TECHNICAL DATA
Type
Primary
current
Secondary
current
Ipn
Isn
Rated power
Sn
kl. 0,2
kl. 0,5
kl. 1
VA
VA
VA
5
7,5
5
7,5
10
5
7,5
10
5
7,5
10
15
5
7,5
10
10
15
600
5
750
IMSb
800
1000
Security
factor for
apparat.
1
lub
7,5
5
7,5
10
15
5
7,5
10
15
5
7,5
10
15
5
7,5
10
15
20
FS
dynamic
(peak)
Idyn
Maximum
permissible
voltage of
transformer
Um
Rated test
voltage
kA
kA
kV
kV
kg
60 x lpn
150 x lpn
0,72
0,7
short-time
Ith
Weight
(about)
Up
5
10
5
10
5
10
5
ABB
Rated current
TECHNICAL DATA
Type
Primary
current
Secondary
current
Ipn
Isn
Rated power
Sn
class 0,2 class 0,5 class 1
VA
VA
400
500
600
750
800
5
7,5
1
IMSc
1000
or
5
7,5
10
5
1200
1500
1600
2000
Security
factor for
apparat.
5
7,5
10
7,5
10
7,5
10
7,5
10
5
7,5
10
5
7,5
10
15
5
7,5
10
15
5
7,5
10
15
20
5
7,5
10
15
20
7,5
10
15
20
7,5
10
15
20
7,5
10
15
20
VA
7,5
10
7,5
10
5
7,5
10
15
5
7,5
10
15
5
7,5
10
15
5
7,5
10
15
20
5
7,5
10
15
20
7,5
10
15
20
7,5
10
15
20
7,5
10
15
20
FS
short-time
thermal
Ith
dynamic
(peak)
Idyn
Maximum
permissible
voltage of
transformer
Um
kA
kA
kV
kV
kg
60 x lpn
150 x lpn
0,72
0,9
Rated current
Rated test
voltage
Weight
(about)
Up
10
5
10
5
10
5
ABB
TECHNICAL DATA
Type
Primary
curent
Secondary
current
Ipn
Isn
[A]
[A]
Parameters of secondary
windings
5 VA class 0,2 FS 10
15 VA class 0,5 FS 5
30 VA class 1 FS 5
5 VA class 0,2 FS 10
15 VA class 0,5 FS 5
30 VA class 1 FS 5
15 VA class 0,2 FS 5
30 VA class 0,5 FS 5
45 VA class 1 FS 5
15 VA class 0,2 FS 5
30 VA class 0,5 FS 5
45 VA class 1 FS 5
30 VA class 0,2 FS 5
60 VA class 0,5 FS 5
60 VA class 1 FS 5
45 VA class 0,2 FS 5
60 VA class 0,5 FS 5
90 VA class 1 FS 5
60 VA class 0,2 FS 5
90 VA class 0,5 FS 5
120 VA class 1 FS 5
1500
1600
2000
1
or
IMSd
2500
3000
4000
5000
Rated current
Weight
(about)
thermal, 1-sec.
dynamic (peak)
Ith [kA]
Idyn [kA]
37,5
100
[kg]
1,3
40
105
50
125
1,5
62,5
156,5
75
187
1,6
100
250
100
250
Maximum
permissible voltage
of transformer
Test
voltage
Extended
current
range
Um [kV]
Up [kV]
ext. % x Ipn
0,72
120% x Ipn
1,8
DIMENSIONAL DRAWING IMSd current transformers for bus bar max 120 x 30 mm or 100 x 50 mm
ABB
Type
Primary
current
Secondary
current
Ipn
Isn
class 1
VA
VA
200
250
300
2,5
2,5
2,5
2,5; 5
2,5; 5
400
5; 7,5
5; 7,5
10
5; 7,5
10
5; 7,5
10; 15
or
5; 7,5
10; 15
5; 7,5
10; 15
750
5; 7,5
10; 15
5; 7,5
10; 15
20
800
5; 7,5
10; 15
5; 7,5
10; 15
20
250
300
2,5
2,5
2,5
2,5
400
2,5; 5
2,5; 5
7,5
500
2,5; 5
7,5; 10
2,5; 5
7,5; 10
600
2,5; 5
7,5; 10
2,5; 5
7,5; 10
15
750
2,5; 5
7,5; 10
15
2,5; 5
7,5; 10
15
2,5; 5
7,5; 10
15
2,5; 5
7,5; 10
15; 20
1000
2,5; 5
7,5; 10
15; 20
2,5; 5
7,5; 10
15; 20
1200
5; 7,5;
10; 15;
20; 30
5; 7,5;
10; 15;
20; 30
1500
5; 7,5;
10; 15;
20; 30
5; 7,5;
10; 15;
20; 30
1600
5; 7,5;
10; 15;
20; 30
5; 7,5;
10; 15;
20; 30
500
600
1
ISWb
800
or
5
Sn
class 0,5
ISWa
Rated power
short-time
thermal
Ith
dynamic
(peak)
Idyn
Maximum
permissible
voltage of
transformer
Um
kA
kA
kV
kV
kg
60 x lpn
150 x lpn
0,72
0,8
60 x lpn
150 x lpn
0,72
0,8
Security
factor for
apparat.
FS
Rated current
Rated test
voltage
Weight
(about)
Up
ABB
Type
Rated
ratio
Rated
power
Sn
class 3
A/A
INSOA
100/5
100/1
150/5
150/1
200/5
200/1
300/5
300/1
400/5
400/1
VA
Security
factor for
apparat.
FS
Rated current
short-time
thermal
Ith
dynamic
(peak)
Idyn
Maximum
permissible
voltage of
transformer
Um
kA
kA
kV
kV
mm
kg
60 x lpn
150 x lpn
0,72
10 x 30
0,4
Weight
(about)
Up
Maximal
dimensions
of cross-section
of a bus
Rated test
voltage
4
5; 7,5
5; 7,5; 10
5; 7,5; 10
5; 7,5; 10
DIMENSIONAL DRAWING INSOA current transformers for cable max 30 mm or bus bar max 30 x 10 mm
Supporting version
ABB
Type
Rated
primary
current
Ipn
Parameters
of secondary winding
for version A =30 mm
Parameters
of secondary winding
for version A =50 mm
[A]
power; class; FS
power; class; FS
[A]
1 VA class 3 FS 5
50
75
IMR0
Rated
Rated test Rated current
secondary
voltage
current
short-time dynamic
Isn
thermal
(peak)
2,5 VA class 3 FS 5
2,5 VA class 1 FS 5
100
2,5 VA class 1 FS 5
1 VA class 0,5 FS 5
4 VA class 3 FS 5
2,5 VA class 0,5 FS 5
150
200
[kV]
[kA]
[kA]
Maximal
cross
-section
of busbar
Weight
(about)
[mm]
[kg]
20 x 5
0,4
2,5 VA class 3 FS 5
1 VA class 3 FS 5
2,5 VA class 3 FS 5
1 VA class 0,5 FS 5
4 VA class 3 FS 5
5 VA class 1 FS 5
2,5 VA class 0,5 FS 5
5
3
1 or 5
4 VA class 0,5 FS 5
DIMENSIONAL DRAWING IMR0 current transformers for cable max 18 mm or bus bar max 20 x 5 mm
75
100
150
200
250
300
400
10
Parameters
of secondary winding
Up
short-time
thermal
dynamic
(peak)
Maximal
cross
-section
of busbar
[A]
[kV]
[kA]
[kA]
[mm]
[kg]
1 or 5
60 x lpn
150 x lpn
20 x 10
0,6
Rated
secondary
current
Isn
Rated test
voltage
power; class; FS
1 VA class 1 FS 5
2,5 VA class 3 FS 5
1 VA class 1 FS 5
2,5 VA class 1 FS 5
2,5 VA class 0,5 FS 5
5 VA class 1 FS 5
5 VA class 0,5 FS 5
7,5 VA class 1 FS 5
5 VA class 0,5 FS 5
7,5 VA class 1 FS 5
7,5 VA class 0,5 FS 5
10 VA class 1 FS 5
10 VA class 0,5 FS 5
15 VA class 1 FS 5
Ipn
[A]
IMR1a
Mass
(about)
ABB
100
150
200
250
300
400
500
dynamic
(peak)
Maximal
cross
-section
of busbar
Weight
(about)
[kA]
[kA]
[mm]
[kg]
60 x lpn
150 x lpn
25 x 10
0,6
Rated
secondary
current
Isn
Rated test
voltage
Up
short-time
thermal
power; class; FS
[A]
[kV]
1 VA class 1 FS 5
2,5 VA class 3 FS 5
1 VA class 0,5 FS 5
2,5 VA class 1 FS 5
2,5 VA class 0,5 FS 5
5 VA class 1 FS 5
2,5 VA class 0,5 FS 5
5 VA class 1 FS 5
5 VA class 0,5 FS 5
7,5 VA class 1 FS 5
7,5 VA class 0,5 FS 5
10 VA class 1 FS 5
10 VA class 0,5 FS 5
15 VA class 1 FS 5
1 or 5
Ipn
[A]
IMR1b
Parameters
of secondary winding
Rated current
Ipn
[A]
power; class; FS
200
5 VA class 1 FS 5
250
5 VA class 0,5 FS 5
10 VA class 1 FS 5
10 VA class 0,5 FS 5
10 VA class 1 FS 5
15 VA class 0,5 FS 5
15 VA class 1 FS 5
15 VA class 0,5 FS 5
20 VA class 1 FS 5
15 VA class 0,5 FS 5
20 VA class 1 FS 5
15 VA class 0,5 FS 5
20 VA class 1 FS 5
15 VA class 0,5 FS 5
20 VA class 1 FS 5
300
IMR2
400
500
600
630
650
ABB
Parameters
of secondary winding
Rated
secondary
current
Isn
Rated test
voltage
Up
short-time
thermal
dynamic
(peak)
Maximal
cross
-section
of busbar
[A]
[kV]
[kA]
[kA]
[mm]
[kg]
1 or 5
60 x lpn
150 x lpn
40 x 10
0,6
Rated current
Weight
(about)
11
DIMENSIONAL DRAWING IMR2 current transformers for cable max 30 mm or bus bar max 40 x 10 mm
Version with secondary
terminals
Manufacturer reserves for itself the right to train the changes resulting from the technological progress.