Professional Documents
Culture Documents
type 1
This type of surge protective
devices are recommended on
electric installations where the
buildings are fitted with lightning
conductor. The minimavalue of
shock current is I imp =12,5 kA.
connection capacity:
- 35 flexible conductor,
- 50 rigid conductor
complies with
EN 61-643.11
For technical details
see pages 55-59
Designation
Characteristics
Width in
17,5 mm
Ref.
SPDs type 1
I imp. 12,5 kA
2 pole 1 Ph + N
Up : 2,5 kV at In
SPA 212A
Un : 230/400 V
50/60 Hz
4 poles 3 Ph + N
Up : 2,5 kV at In
SPA 412A
SPA 412A
Available in 2 versions :
SPDs with base and plug in
cartridges with an end of life
indication LED
SPDs with base and auxiliary
contact for remote signallings
and plug in cartridges with
reserve protection indicator .
This version, with reserve
indicator, shows the intermediary
state, with indication of the need
to change the cartridge before
disconnection, but keeps the
maximal protection capacity till
the end.
connection capacity of
terminal blocks, (L, N/E) :
- 16 flexible conductor,
- 25 rigid conductor
for auxiliary contact :
- 0,5 mini
- 1,5 maxi
degree of protection : IP 203
(in enclosure).
Designation
Characteristics
Width in
17,5 mm
Ref.
IP
with reserve indicator and
remote signalling
Up : 1,3 kV at In
SPN 165R
2 poles 1 Ph + N
with reserve indicator and
remote signalling
Up : 1,3 kV at In
SPN 265R
4 poles 3 Ph + N
with reserve indicator and
remote signalling
Up : 1,5 kV at In
SPN 465R
Un : 230/400 V
50/60 Hz
SPN 265R
SPN 465R
31
Characteristics
Width in
17,5 mm
Ref.
- single pole 1 Ph
Up : 1,2 kV at In
- single pole 1 Ph
Up : 1,2 kV at In
- 2 poles 1 Ph + N
with reserve indicator and
remote signalling
Up : 1,2 kV at In
- 2 poles 1 Ph + N
Up : 1,2 kV at In
- 4 poles 3 Ph + N
with reserve indicator and
remote signalling
Up : 1,2 kV at In
- 4 poles 3 Ph + N
Up : 1,2 kV at In
SPD 140D
SPN 140D
SPN 240R
SPD 240D
SPN 440R
SPD 440D
- 2 poles 1 Ph + N
with reserve indicator and
remote signalling
Up : 1,0 kV at In
- 2 poles 1 Ph + N
Up : 1,0 kV at In
- 4 poles 3 Ph + N
with reserve indicator and
remote signalling
Up : 1,0 kV at In
- 4 poles 3 Ph + N
Up : 1,0 kV at In
SPN 215R
SPD 215D
SPN 415R
SPD 415D
I max. 40 kA
Un : 230/400 V
50/60 Hz
SPN 240R
SPN 415R
Replacement cartridges
for SPDs with plug in cartridge
Replacement cartridges
The cartridge allows simple
replacement without the need to
cut-off the power supply.
Designation
Characteristics
Replacement cartridges
Width in
17,5 mm
Ref.
SPN 065R
SPD 140D
SPD 015D
SPN 040R
SPD 040D
SPN 015R
SPD 015D
SPN 065N
SPN 040N
SPN 065R
SPN 065N
32
SPD 040D
Discharge current :
I max. 8 kA (8/20 wave).
Connection capacity :
- 6 flexible conductor
- 10 rigid conductor .
complies with
NF EN 61-643-11
september 2002
Degree of protection : IP 20
(in enclosure).
Designation
Characteristics
Width in
17,5 mm
Ref.
SPD
with low voltage protection level
2 poles 1 Ph + N
SPN 208S
Un : 230/400 V
50/60 Hz
4 poles 3 Ph + N
SPN 408S
2poles 1Ph+N
230V
SPN 208
Discharge current :
I max 10 kA (8/20 wave).
Complies with
IEC 61643-21
SPDs
for telephone lines
SPDs for telephone lines.
For the protection of receiver
against transient current surge
vehicled by telephone lines (fax,
modem, etc...)
Protection is assured in both
common and differential modes
Connection capacity
- 0,5 2,5 flexible conductor
- 0,5 2,5 rigid conductor
Degree of protection : IP 10
(in enclosure).
Characteristics
Width in
17,5 mm
Ref.
Un : 130 V
Up : 600 V
SPN 505
Un : 40 V
Up : 600 V
SPN 504
SPN 505
33
SPDs
Installation example
D.B.
500 mA
S F
telephone line
L1
C1
32 A max.
SPN 208S
SPN 408S
SPN 504
SPN 505
general SPD
with plug on
cartridge
sensitive equipment
Distressing of SPD
C1 (1)
SPN 265R
SPN 465R
32 A curve C
SPD 140R/D
SPD 240R - SPD 240D
SPD 440R - SPD 440D
SPD 215R - SPD 215D
SPD 415R - SPD 415D
32 A curve C
32 A curve C
Successive discharging of current due to lightning reduces progressively the performance of SPDs, with the consequence of a possible
short circuit for the installation.
For this reason, all our SPDs are fitted with an automatic thermic and
dynamic disconnection device
LED on front indicates the good working of the device :
- for normal version :
green = OK red = replacement
- for version with reserve indicator :
green = OK yellow = caution
red = replacement
- for version with electric LED for SPDs for fine protection
green = OK LED off = replacement
Warranty
Warranty can not be applied for SPDs as their life expectancy
depends on the perturbation level absorbed to protect the electric
installation.
55
base
reserve
indicator
end of life
LED
plug in
cartrige
OK
14
14
12
12
12
14
11
2 poles or
4 poles base
auxiliary contact
connection capacity
mini
maxi
0,5 mm
1,5 mm
remote signalling
voltage
ominal current
230 V
1A
11
Connection diagrams
Single pole SPDs :
protection only in common mode
IT / TN-C
L2
L1
L2
L3
L3
N
N
d1
d1
d1 50 cm
d1 + d2 50 cm
PE
d2
PEN
56
250 V ...
0,1 A
PEN
PE
SPA 212A
SPA 412A
very high
installation of SPDs
in parallel
nominal voltage Un
frequency
Max. continuous operating voltage Uc
230 V
50/60 Hz
255 V
2,5 kV
protection mode
common
differential
shock current
Iimp
12,5 kA
disconnection value
Ifi
12,5 kA
yes
earthing systems
TT - TNS
max.connection capacity
flexible
rigid
screw head
SPD 140D
SPN 140R
medium
installation of SPDs
in parallel
nominal voltage Un
frenquency
230 V
50/60 Hz
440 V
rfrences
2 kV
15 kA
40 kA
degree of protection
IP 20
20 kA - 32 A
temperature
-20 + 60C
-40 +70C
working
storage
SPN 140C
domestic building
yes
yes
collective/individual
industrial/commercial
earthing systems
IT, TN-C
25 mm
35 mm
PZ3
screw head
25 mm
35 mm
flexible
rigid
PZ2
SPN 265R-SPN 465R SPN 240R, SPN 440R SPN 215R, SPN 415R
SPD 240D, SPD 440D SPD 215D, SPD 415D
very high
medium
low
installation of SPDs
in parallel
in parallel
in parallel
nominal voltage Un
frenquency
230/400 V
50/60 Hz
230/400 V
50/60 Hz
230/400 V
50/60 Hz
255 V
275 V
255 V
275 V
255 V
275 V
protection mode
yes
yes
yes
yes
yes
yes
1,5 kV
1,2 kV
1,0 kV
20 kA
65 kA
15 kA
40 kA
5 kA
15 kA
20 kA - 32 A
10 kA - 32 A
common
differential
nominal current In
maxial current Imax
degree of protection
IP 20
(MCB - curve C)
20 kA - 32 A
working temperature
-40C +60C
SPN 265R - SPN 465R SPN 240R - SPN 440R SPN 215R - SPN 415R
domestic buildings
yes
yes
collective / individual
industrial / commercial
earthing systems
connection capacity
(Ph, N, E)
screw head
TT
TN - S
flexible
rigid
TT
TN - S
TT
TN - S
25 mm
35 mm
PZ2
57
references
SPN 208S
SPN 408S
low
low
installation of SPDs
in parallel
in parallel
nominal voltage Un
frequency
230 V
50/60 Hz
255 V
255 V
230/400 V
50/60 Hz
255 V
255 V
yes
yes
yes
yes
1,0 kV
1,0 kV
2 kA
8 kA
2 kA
8 kA
degree of protection
IP 20
IP 20
6 kA - 32 A
6 kA - 32 A
temperature
-25C +40C
-25C +40C
-25C +40C
-25C +40C
green LED
green LED
yes
yes
yes
yes
TT, IT,
TN - S
TT, IT,
TN - S
2,5/6 mm
6/10 mm
2,5/6 mm
6/10 mm
common
differential
nominal current In
maximal current Imax
working
storage
collective / individual
industrial / commercial
earthing systems
connection capacity
(Ph, N, E)
flexible min./max.
rigid min./max.
screw head
PZ1
15 / 90 A
500 mA
S
F1
C1
L1
C2
L2
L3
L1 L2 L3
SPN 408S
PE
PE
PE
PE
L1 L2 L3
32 A
32 A
L
N
SPN 208S
L1 L2 L3
OK
SPN x 15 kA x
SPN x 40 kA x
SPN x 65 kA x
SPN 408S
N
58
SPN 208S
SPN 408S
Up = 800 V
SPN 504
SPN 505
analog line
installation of SPDs
in series
in series
ingress protection
IP 10
IP 10
nominal voltage Un
5 V / 40 V
130 V
7,5 V / 60 V
170 V
600 V
600 v
yes
yes
yes
yes
1,0
4,7
10 kA
5 kA
5 kA / 10 kA (RJ 45 / vis)
2,5 / 5 kA (RJ 45 / vis)
-40C + 60C
-40C + 60C
common mode
differential mode
In (total)
In (line)
working temperature
connection
in
out
screw
screw / RJ 45
screw / RJ 45
screw / RJ 45
connection capacity
(Ph, N, T)
flexible min./max.
rigid min./max.
0,08 mm
2,5 mm
0,08 mm
2,5 mm
digital line
ISDN, RNIS
analog line
applications
Electrical connection
SPN 504
SPN 505
cables
cables RJ45
or
a2 a1 b1 b2
a1 b1
IN
IN
SPN 504
SPN 505
OUT
a2 a1 b1 b2
cables
PE
OUT
a1 b1
RJ 45
cables
or
A1
A2
R2 R3
V2
a1 b1
12345678
A1
V1
PE
or
a2 a1 b1 b2
R1
RJ45
R4
V3
V4
R2
R1
V1
V5
12345678
a2 a1 b1 b2
12345678
a1 b1
wire
59