You are on page 1of 31

Internal

OptiX SDH/OSN Series


Equipment General
Configuration
www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

References
 OptiX T2000 Operator Guide for SDH
 OptiX iManager T2000 Administrator
Guide for SDH
 OSN3500&2500&1500 Configuration
Guide
 OSN7500 Configuration Guide

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 1

 Upon completion of this course, you will be able to:


 Understand the menus of OptiX iManager T2000
 Create Topology including create NE/Link
 Perform the NE configuration, board configuration,
service dispatching and protection configuration for
equipment via OptiX iManager T2000
 Perform the Security Management, including Create NE
User, managing NE/T2000 login

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 2

Chapter 1 Creating Topologies


Chapter 2 Configuring Protection
Chapter 3 Configuring Services
Chapter 4 Configuring Clock
Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

Chapter 6 Configuring Alarm and Performance


Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 4

Creating Topologies
 Recommended Creation Sequence
Step

Description

Creating GNEs & NEs

Creating a Sub-racks and Boards

Creating Links

Creating a Topology Subnet

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 5

Creating Topologies


Creating Optical NEs in batch

 Select [File/Search for NE] from the Main


Menu.
 Click <Start Search>. The NEs found are
displayed after the search.
 Click <Stop Search>, and click <Yes> in
the confirmation box.
 Click <Create NE>.
 Enter the NE user name and password.
 Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 6

Creating Topologies


Creating Optical NEs Manually

Creating Gateway Network Element (GNE)

1. Click File/Create/Topology Object.


2. Choose the NE type to be created.
3. Complete the following information: ID,
extended ID, name and remarks.
4. Select "Gateway" from the "Gateway Type"
drop-down list and "IP" from the "Protocol"
drop-down list. Enter the IP address and
port number of the GNE.
5. Enter the NE user and password.
6. Click <OK>.
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 7

Creating Topologies


Creating Optical NEs Manually

Creating Non-Gateway Network Element

1. Click File/Create/Topology Object.


2. Choose the NE type to be created.
3. Complete the following information: ID,
extended ID, name and remarks.
4. Select "Non-Gateway" from the "Gateway
Type" drop-down list. Select the GNE the
NE is affiliated to from the "Affiliated
Gateway" drop-down list.
5. Enter the NE user and password.
6. Click <OK>.
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 8

Creating Topologies

Creating Sub-racks and Boards (1/2)

 Double-click unconfigured NE icon on the Main Topology.


 Select "Manual Configuration" and click <Next>.
 Click <OK> in the two "Confirm" dialogue box.
 Set the NE attributes and click <Next>.
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 9

Creating Topologies

Creating Sub-racks and Boards (2/2)

The NE Panel is displayed.

1. Right-click the slot and select the board type or Click


<Query Physical Slot (s)> to upload the data to the
physical slot from the NE.
2. After all the boards have been created, click <Next>.
3. Click <Finish>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 10

Creating Topologies



Searching fibers

 Select [File/Search for Fiber/Cable].


 Click <Search>.
 After finding the fibers, Click <Close>.
 Click <Create Fibre>.

Creating fibers manually

1. Select the shortcut icon on the


toolbar of the Main Topology and
the cursor changes to a "+".
2. Click the source NE of the fiber or
cable on the Main Topology.
3. Select the source board and port.
4. Click <OK> and the cursor
changes to a "+".
5. Click the sink NE of the fibre or
cable on the Main Topology.
6. Select the sink board and port
7. Click <OK> twice.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 11

Creating Topologies
 Creating a Topology Subnet

1. Select [File/Create/Subnet].
2. Select the "Basic Attributes" tab. Enter the
information of the subnet.
3. Select the "Object Selection" tab. Select
the created NEs or subnet from the "Object
Not Selected" pane, and add them to the
"Selected Object" pane by clicking the
double-right-arrow button.
4. Click <OK>.
5. Click in the Main Topology.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 12

Chapter 1 Creating Topologies


Chapter 2 Configuring Protection
Chapter 3 Configuring Services
Chapter 4 Configuring Clock
Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 13

Configuring Protection
Equipment level protection

Configuring TPS Protection

Configuring Board-level Protection

Network level protection

Configuring MSP Ring

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Configuring SNCP

Page 14

Configuring Protection
Equipment Level Protection


Configuring TPS Protection

 In the NE Explorer, click the NE and select [Configuration/TPS


Protection] from the Function Tree.
 Click <Create> to enter the dialog box .
 Select a protection board and working boards. Set switching priorities
for the working boards.
 Set the "WTR Time.
 Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 15

Configuring Protection

 Creating Board-level Protection

 In the NE Explorer, click the NE and select [Configuration/Board-Level


Protection] from the Function Tree.
 Click <New>.
 Select Primary Board and Standby Board, and set Protection Group ID.
 Click <OK>.
 Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 16

Configuring Protection
Network Level Protection
 Creating a Two-Fiber MS-SPRing
 Select [Configuration/Protection View]
 Select [Protection View/Create SDH Protection Subnet/2f_MS SPRing].
 Select the rate of the protection subnet.
 Double-click on the nodes to be in the protection subnet.
 Click <Next>.
 Click <Finish> to send the configurations.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 17

Configuring Protection


Configuring SNCP Protection

 Select [Configuration/Protection View] from the Main Menu.


 Right-click the NE to be created as the SNCP node, and select
[Create SNCP Node/Create xxx SNCP Node] ("xxx" refers to the
name of the protection subnet of this NE)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 18

Chapter 1 Creating Topologies


Chapter 2 Configuring Protection
Chapter 3 Configuring Services
Chapter 4 Configuring Clock
Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 19

10

Configuring Service
Configuration Method

Using the Trail Management


Function

Using the Single Station


Function

Service type

Configuring
SDH/PDH service

Configuring
Ethernet service

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Configuring
ATM service

Page 20

Method 1 -- Using the Trail Management Function


 Configure SDH/PDH service
 It is recommended to configure SDH services by the
process below
Stage

Description

Remark
According to trail level:

Creating an SDH trail

 Creating a VC4 Server Trail


 Creating a VC4/VC4-Xc Trail
 Creating a VC12/VC3 Trail

Changing Trail Type

Viewing Trail

Configuring the Maintenance


Parameters of a Created Trail

Deleting a Trail

HUAWEI TECHNOLOGIES CO., LTD.

Optional

Optional

All rights reserved

Page 21

11

Method 1 -- Using the Trail Management Function


 Creating a VC4 Server Trail
 Select [Trail/SDH Trail Creation] from the Main Menu.
 Set the service direction to "Bidirectional" and level to "VC4 Server Trail".
 Double-click the source NE and then the sink NE. The trail selected
automatically will be displayed between the NEs.
 Set a name and ID for the route.
 To send the configurations to the NE, select the "Activate" checkbox.
(optional)
 Select the "Copy after Creation" checkbox if you want to create multiple
trails with the same route. (optional)
 Click <Apply>. The "Operation Result" dialogue box is displayed and
indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 22

Method 1 -- Using the Trail Management Function


 Creating a VC4 Server Trail

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 23

12

Method 1 -- Using the Trail Management Function


 Creating a VC-12/VC3 Trail
 Select [Trail/SDH Trail Creation] from the Main Menu.
 Select the service direction and set the service level to "VC12" or "VC3".
 Double-click the source NE and then the sink NE. Select the port in the
"Create Trail-Select Board Port" dialogue box and click <OK>.
 Click the "Trail setting" tab. Set a name and ID for the route.
 To send the configurations to the NE, select the "Activate" checkbox.
 Select the "Copy after Creation" checkbox if you want to create multiple trails
with the same route. (optional)
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates
operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 24

Method 1 -- Using the Trail Management Function


 Creating a VC-12/VC3 Trail

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 25

13

Method 2 -- Using the Single Station Function


 Configure SDH/PDH service
 In the NE Explorer, click the NE
and select [Configuration/SDH
Service Configuration] from the
Function Tree.
 Click <Create>.
 Complete the information as
required.
 Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 26

Chapter 1 Creating Topologies


Chapter 2 Configuring Protection
Chapter 3 Configuring Services
Chapter 4 Configuring Clock
Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 27

14

Configuring Clock
 Setting the System Clock Source Priority List
 Setting Switching Conditions for a Clock Source
 Setting Restoration Parameters for a Clock Source
 Setting an External Clock Source
 Setting the Clock Subnet

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 28

Configuring Clock

Setting the Priority Table for a Reference Clock

 Select [Configuration/Clock View] from the Main Menu.


 Right-click the NE icon in the Clock View and select [Clock Source Priority
List].
 Click <Create>, and the "Add Clock Source" dialogue box is displayed.
 Select a reference clock source and click <OK>.
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates
operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 29

15

Configuring Clock

Setting Switching Conditions for a Clock Source

 In the NE Explorer, click the NE and select [Configuration/Clock/Clock


Source Switching] from the Function Tree.
 Select the "Clock Source Switching Condition" tab. Click <Query>.
 Double-click the parameters to set clock switching conditions.
 Click <Apply>. The "Operation Result" dialogue box is displayed and
indicates operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 30

Configuring Clock


Setting Restoration Parameters for a Clock Source

 In the NE Explorer, click the NE and select


[Configuration/Clock/Clock Source Switching] from the Function
Tree.
 Select the "Clock Source Reversion Parameter" tab. Click
<Query>.
 Double-click the parameters to set restoration parameters.
 Click <Apply>. The "Operation Result" dialogue box is displayed
and indicates operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 31

16

Configuring Clock


Setting an External Clock Source

 Right-click the NE icon in the Clock View and select [Clock Source
Priority List].
 Set "External Clock Source Mode" and "Synchronous Status Byte"
for the external clock source.
 Click <Apply>. The "Operation Result" dialogue box is displayed
and indicates operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 32

Configuring Clock


Setting the Clock Subnet ---- Setting a Clock Subnet Attributes

 Right-click the NE icon in the Clock View and select [Clock Subnet Settings].
 On the "Clock Subnet" tab, set the clock subnet parameters.
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation
succeeded. Click <Close>.
 Select the "Clock ID Status" tab. If a clock ID is assigned to the line clock source, set
"Clock ID Status" to "Enabled".
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation
succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 33

17

Configuring Clock


Setting the Clock Subnet --- - Setting Clock Source Quality

 Right-click the NE icon in the Clock View and select [Clock Subnet Setting]. Click the "Clock
Quality" tab.
 Set "Configuration Quality".
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation
succeeded. Click <Close>.
 Select the "Manual Setting of 0 Quality Level" tab. Set the quality for the unknown clock
source.
 Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation
succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 34

Configuring Clock


Setting the Clock Subnet ---- Setting SSM Output

 Right-click the NE icon in the Clock View and select [Clock Subnet
Setting]. Click the "SSM Output Control" tab.
 Set "Control Status" of the clock source.
 Click <Apply>. The "Operation Result" dialogue box is displayed
and indicates operation succeeded. Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 35

18

Chapter 1 Creating Topologies


Chapter 2 Configuring Protection
Chapter 3 Configuring Services
Chapter 4 Configuring Clock
Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 36

Configuring Overhead Interface




Configuring the Orderwire


Phone

 In the NE Explorer, click the NE and


select [Configuration/Orderwire] from
the Function Tree. Select the
"General" tab.
 Set "Call Waiting Time (s)", "Dialing
Mode", "Telephone No." and the
Orderwire ports.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 37

19

Chapter 6 Configuring Alarm and Performance


Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 38

Setting Alarm Dump Conditions


 1.Select [System Administration/Database

Management/Dump] from the Main Topology.


 2. Select the Dumping Conditions tab. In the

left-hand Record Type list, select Alarm


Event .
 3. In the right-hand pane, under Dumping

when Overflow, set a value for Max. Storage


Capacity, Number of Dumped Records and
Capacity Alarm Threshold respectively.
 4. Under Dumping in Schedule, set "Dump

Periodically or not" to "Yes".Set "Dump


Interval" and "Time Limit" , then click <OK>

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 39

20

Setting Performance Monitoring Start/Stop Status


1.Select [Configuration/NE Time Synchronization] from the Main Topology
2. Select NEs from the object tree and then right click to select [Synchronize with NM Time].

Click <Yes> in the pop-up confirmation box.


3.A dialog box is displayed to prompt that synchronization succeeded. Click <OK>
4.Select [Performance/NE Performance Monitor Time] from the Main Topology
6.Perform the following settings , then Click <Apply>
Set 15-minute Monitoring: Open
Set 24-hour Monitoring: Open
Start time: set as required and must be later than the current time of the NM and NE.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 40

Chapter 6 Configuring Alarm and Performance


Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8

NE Security Management

Chapter 9

Configuring Communication

Chapter 10 Configuring Board Parameters


Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 41

21

Synchronization and Data Management


 Synchronizing NE Time
 Synchronizing Current NE Alarms
 Managing NE Configuration Data
 Backing Up/Restoring the NE Database Using FTP

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 42

Synchronizing NE Time with the NM Server

 Manual Synchronization

 1.Select [Configuration/NE Time Synchronization] from the Main Menu


 In the left pane, select one or more NEs
 2.Modify the value of Synchronize Mode to NM then click <apply>-<close>
 3.Select one or more NE entries. Right-click and select [Synchronize with
NM Time].
 Automatic Synchronization
 1.Select [Configuration/NE Time Synchronization] from the Main Menu.
 2.In the left pane, select one or more NEs
 3.Set Synchronize Starting Time and Synchronization Period.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 43

22

Synchronizing Current NE Alarms


Synchronizing

Networkwide Alarms

Select

[Fault/Synchronize Networkwide
Alarms] from the Main Menu. A progress bar is
displayed.

Synchronizing
Select

NE Alarms

an NE in the Main Topology

Right-click

the selected object and select


[Synchronize Current Alarm]. A progress bar is
displayed.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 44

Backing Up NE Configuration Data


1.Select
2.In

the left pane, select the desired NEs

3.Select
4.Click
5.A

[Configuration/Configuration Data Management] from the Main Menu

one or more NEs in the Configuration Data Management List.

<Backup NE Database>. This is also available in the shortcut menu

dialog box is displayed to prompt that backup succeeded. Click <Close>

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 45

23

Backing Up NM Configuration Data


1.Select [File/Logout] from the Main Topology. Click <OK> in the subsequent prompt.
2.Enter the following in the login interface
3.Select [System Administration/Single User Mode] from the Main Topology. Click

<OK> in the subsequent prompt.


4. To backup immediately :Select [System Administration//Database

Management/Backup] from the Main Topology. Select immediate backup, and the
system backs up the NM database to the appointed directory immediately
5.To backup periodically, perform the following settings

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 46

Chapter 6 Configuring Alarm and Performance


Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 47

24

Creating an NE User
1.Select

[System Administration/NE Security Management/NE User Management]


from the menu

2.Select

NE from the object tree. Select NE and click <Add>.

3.Enter

the name, user level, user flag, password, and detailed description of the
new NE user: e.g. create a unified NE user t2000 for NE1NE5, as shown in the
diagram below. The length of the password of the NE user ranges from 6 to16
characters, including at least one letter and one numeral. And the length of the NE
User ranges from 2 to 8 characters

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 48

Chapter 6 Configuring Alarm and Performance


Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 49

25

Configuring communication
 Setting NE Communication

Parameters
 1. In the NE Explorer, click the

NE and select
[Communication/Set
Communication Parameters]
from the Function Tree
 2. Click <Refresh> to update

the communication
parameters
 3. Modify the IP, Extended ID,

Gateway IP, Subnet Mask or


NSAP Address as you need,
and click <Apply>.
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 50

Configuring communication
 Changing an Ordinary NE into a GNE
 1. Select [System Administration/DCN Management] from the Main Menu
 2. Select the NE tab.
 3. Right-click an ordinary NE and select [Change to GNE]. The Change to

GNE dialog box is displayed;


 4. Set the GNE type, IP Address and Port No. as you need

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 51

26

Configuring communication
 Adding Standby GNEs for an NE
 1. Select [System Administration/DCN Management] from the

Main Menu
 2. Select the NE tab
 3. Select an NE entry, add standby GNEs
 4. Click <Apply>

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 52

Chapter 6 Configuring Alarm and Performance


Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 53

27

Configuring Board Parameters


 Configuring SDH Boards
 Configuring PDH Boards
 Configuring Ethernet Boards
 Configuring Optical Amplifier Boards
 .

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 54

Configuring the Optical Transponder Unit


1,

In the NE Explorer, select an SDH board and select


[Configuration/SDH Interface] from the Function Tree ;

2,

Click the double-right-arrow button (red). Select "By Function" ;

3,

Select the parameter in the drop-down list ;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 55

28

Chapter 6 Configuring Alarm and Performance


Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 56

Reports
 The Network Diagram
 The Network wide Data Report
 The NE Information Report
 The Physical Location Information Report
 The Slot Configuration Report
 The Board Information Report
 The Slot Information Report
 The Board Details Report
 The Fiber/Cable Connection
 Report
 ..
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 57

29

Reports
The

Network wide Data Report

1, Select [Report/Network wide


Data Report] from the Main Menu;
2, Click <Print> or <Save As>.
The

Board Information Report

1. Select [Report/Board Information Report]


from the Main Menu ;
2. Select NEs from the left pane and click
the double-right-arrow button (red)
3. Select the "View Board Information" tab.
Click <Print> or <Save As>
HUAWEI TECHNOLOGIES CO., LTD.

Summary

All rights reserved

Page 58

 How to configure the SDH service?

answer
 How to configure the clock? answer
 How to backup the NE data

configuration? answer

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 59

30

Thank You
www.huawei.com

31

You might also like