You are on page 1of 4

Hydraulic Safety Valves

Spool or Cartridge valves equipped with mechanical micro-switches or


inductive proximity sensors

These valves are designed to block and/or


bleed hazardous energy in hydraulic fluid
systems They are used to shut off the fluid
energy to one ore more actuators as a
consequence of the opening of a safety
device (gate, presence sensor, enabling
device etc.) or as a consequence of an
emergency stop command.
When the valve coil is de-energized, the
spool/poppet returns to the blocked (safe)
position where an electrical output signal
is produced indicating the position of the
spool/poppet. The electrical signal can
then be monitored by a safety rated control
system to ensure that the valve has
returned to the safe position. Two
versions of electrical output signals are
available: mechanical micro-switch or
inductive proximity sensor.
These valves are available in spool
and cartridge configurations. Single and
dual (series) manifolds are available that
can be installed to block fluid energy and/or
bleed hydraulic energy that may be trapped
in the system.
They are CE compliant and designed to
fulfill the safety criteria of the Machinery
Safety Directives EN 982, EN 201, EN
422, EN 693 and EN 12622. When
configured on a dual (series) manifold and
monitored by a safety rated control
system, they meet the requirements of a
Category 3 safety device according to ISO
13849 Safety of Machinery.

Model Code/Part Number Selection:


SVCSIZE
06 = NG06 (D03) Direct Acting
10 = NG10 (D05) Direct Acting
16 = NG16 (D07) Pilot Operated
25 = NG25 (D08) Pilot Operated
VALVE SPOOL (Neutral Position)
1 = All Ports Blocked
2 = P-A; B-T
MONITOR TYPE
S = Mechanical Micro Switch (NO & NC)*
P = Inductive Proximity Switch (NC)**
Contact is closed when valve spool is in
the neutral (safe) position.
* Available on NG06 & NG10 sizes only.
**Available on NG16 & NG25 sizes only.
Valve Spools

24V-

-21
DESIGN NUMBER
ASSEMBLY OPTIONS
Omit if ordering valve only (no manifold)
1A = 1 Valve assembled on single manifold
1F = Same as 1A plus Flow Amplifier
1P = Same as 1A plus Pressure Relief Valve 2A
= 2 Valves assembled on dual manifold
2F = Same as 2A plus (2) Flow Amplifiers
2P = Same as 2A plus (1) Pressure Relief Valve
WIRING OPTIONS
W = Wiring Junction Box Thread
Q = Quick Disconnect 5-pin Male Connector. Mating
connector & cable sold separately
D = DIN 43650 (Form A) Male Connectors. Mating DIN
connectors sold separately.
COIL VOLTAGE
24V = 24VDC

OPERATING LIMITS

Max pressure P port:

350 bar (for all valves)

TECHNICAL CHARACTERISTICS OF MECHANICAL MICRO-SWITCHES AND INDUCTIVE PROXIMITY SENSORS

MECHANICAL MICRO-SWITCHES
With resistive
load
125V
5A
AC
250V
5A
Max switching power
30V
5A
50V
1A
DC
125V
0.5 A
250V
0.25 A
Mechanical life
Min 107 cycles

Max pressure T port (bar), peaks included


Mechanical Microswitch
20 (1)
Inductive Proximity
5 (1)

With inductive
load
5A
5A
3A
1A
0.03 A
0.03 A

INDUCTIVE PROXIMITY SENSORS


Supply voltage
[V]
10 30
Ripple max
[%]
10
Max current
[mA]
200
Power consumption
[mA]
10
Voltage drop
[V]
1.8
Max switching frequency
[Hz]
1500
Max peak pressure
[bar]
20
Mechanical life
Infinite

CONNECTING SCHEMES OF MECHANICAL MICRO-SWITCHES AND INDUCTIVE PROXIMITY SENSORS

ALL VALVES WITH


MECHANICAL
MICROSWITCH
Connector type DIN 43650

NG06 & NG10 VALVES


WITH INDUCTIVE
PROXIMITY SENSORS
Connector type DIN 53650

NG16 & NG25 VALVES


WITH INDUCTIVE
PROXIMITY SENSORS
Lead Wire Type

1 = common (C)
2 = normally open contact (NO)
3 = normally closed contact (NC)
= EARTH GROUND

1 = output signal S
2 = supply +24 V DC
= common 0V DC

Black = output signal S


Brown = supply +24 V DC
Blue = common 0V DC

NG06 (D03) DIMENSIONS [mm]

NG10 (D05) DIMENSIONS [mm]

NG16 (D07) DIMENSIONS [mm]

NG25 (D08) DIMENSIONS [mm]