Professional Documents
Culture Documents
</06
Single Quadrupole Compact Mass Spectrometer for Liquid Sample
YL
:KDWLV</06"
YL9900 MS quickly provides essential information and improves the chemist's workflow.
Mordern organic labs have become automated, yet real-time mass assays remain just out
of reach.
YL9900
MS solves this !
YL 9900 MS is the smartest instrument for performing a mass spec solution, if you are a biopharmaceutical
company, academic teaching/research lab or any industry requiring mass assays.
</06'HOLYHUV
6RIWZDUH
An inviting interface with powerful depth
- Mass ExpressTM, Data ExpressTM.
YL-Clarity both LC and MS with MS Extension only.
0D[LPL]H\RXU5HVXOWVDQG,QYHVWPHQW
Elegant stand - alone Integrated solution
FIA/MS
)ORZ,QMHFWLRQ$QDO\VLV
'LUHFW,QMHFWLRQ
Guard
Column
Isocratic
Pump
10 ~ 500 L/min
Methanol of Acetonitrile
with 0.1% Formin Acid
To ESI of
APCI Ion
Source
6-port Direct
Injection Valve
LC or UPLC/MS
Optional splitting
T for flows above
500 L/min
/&RU83/&06
A mass detector which can be integrated into
existing HPLC and UPLC systems
Replacing expensive mass spectrometers
purchased from another era
Column
50 L/min to 2 mL/
min eluent
Autosampler
Contact Closure
O/P
Contact
Closure I/P
HPLC or UPLC
system
Flow synthesis/MS
Flow Reactor
)ORZ6\QWKHVLV06
Rheodyne MRA
100 Mass Rate
Attenuator Valve
To Waste
Collection
Vial
Column
)ODVK06
Prep scale
LC or
NPFC with
Fraction
Collector
Return to UV
300 L/min
To ESI Mass
Spectrometer
UV I/P
Analog O/P
Isocratic Pump
Flash/MS
7/&06
6 port
valve
1 ~ 200 L/min 80/20
Acetonitrile or
Methanol with 0.1%
Formic Acid
Isocratic
Pump
Piston Head
Sealing Face
TLC Plate
TLC/MS
0DVV([SUHVVIRUWKH06FRQWURO
'DWD([SUHVVIRUWKH'DWDSURFHVVLQJ
Simple!
We focused in the minimum steps and most efficient range of motion required for decision-bearing answer.
Ultimate confidence!
You can export cdf and csv files and you have thought of all possible options for data archiving and interpretation.
$XWRWXQH
The YL9900 MS uses a pressurize
calibrant delivery system for both
positive and negative tuning mixes
which are placed inside.
You can also set parameters manually.
Tetramethylammonium,
74.10
Tetrabutylammonium,
242.28
Tetradecylammonium,
578.66
Tetraoctadecylammonium,
1027.16
10 pmol/L infusion of Quaternary Amine Mix abundant peaks are tetra alkyl ammonium ions
6HQVLWLYLW\
You can overcome poor resolution
S/N 140:1
S/N 115:1
Time in seconds
$SSOLFDWLRQ
Whether your application is FIA,
Flash, LC, UPLC or flow reaction
monitoring, our data acquisition
and workflow approaches are the
Minutes:Seconds
FIA / MS
After 5 min Room Tem
TLC / MS
Peptide Product
Reactant
Product
same.
After 100 min Room Temp
Reactant
Product
3RZHUIXO</&ODULW\
4
4
4
No Product
7KH&+,()0$7(RI\RXU/$%
4 &RPSDFW6L]H
4 +LJK3HUIRUPDQFH
4 ,GHDO'HVLJQ
4 (DV\2SHUDWLRQ
4)DVW$QDO\VLV
</06
Unrivalled expertise in mass spectrometry
just for the chemist
Ionization
technique:
Patent-
$3&,
Atmospheric Pressure
Chemical Ionization
pending design
Liquid Introduction
Nebulization Gas
Heated Drying Gas
Nebulization Gas
APCI Probe
Electrospray Probe
~2 mbar
Boost
Stage
~5 x 10-3 mbar
Drag
Stage
To Roughing Pump
Quadrupole Analyzer
Dynode
~2 mbar
~5 x 10-6 mbar
Turbo
Molecular
Pump
Electron
multiplier
Detector
Boost
Stage
~5 x 10-3 mbar
Drag
Stage
To Roughing Pump
Quadrupole Analyzer
Dynode
~5 x 10-6 mbar
Turbo
Molecular
Pump
Electron
multiplier
</06
The smartest mass spec designed just for Chemists!
Specification
YL9900 MS
Mass Analyzer
Single Quadrupole
Mass Range
10 - 1,200 m/z
Scan Speed
5,000 m/z/s
Ion Source
Polarity
Positive / Negative
10 - 500 L/min
Resolution
Sensitivity
Accuracy
0.1 m/z
Stability
Gas
N2, 98 %, 60 psi
Gas Consumption
8 L/min
Weight
32 kg
Dimensions H W D, mm
Power Consumption
Max. 300 VA MS
Max. 550 VA Rotary pump
Software
Warranty
1 year
KOREA MADE
'DWH