You are on page 1of 21

1.

Which PCIe slots are available in a T5-4 system with one CM?
revoir
(1) Points

Question

One through eight


One through fourteen (*)
One through fifteen
One through sixteen

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

2.
Which of the following are applicable or characteristic
of a "Hot-Service" component. Question revoir
(1) Points
(Choisir toutes les rponses correctes)
refers to an operation where you walk up to the box, yank something out,
replace it, and you are done Refers to an operation where you walk up to the sy
stem, remove the board or component, replace it, and you are done
Typical examples would be PCIe Express modules (*)
The system will notify the user when it is safe to remove the component
(*)
refers to the ability to perform hot-plug operations, with the additiona
l necessity of some operator actions (invocation of a CLI or actuating a hot ser
vice button on the component to be removed) (*)

[Correcte]

Correct!
3.

What is Critical Thread Optimization?

Question revoir

(1) Points
The ability to dynamically alloate core resources among active threads
The ability to bind individual threads to a processor

Part of the Processor Sets feature of Oracle Solaris that defines a grou
p of logical processors and schedules threads on them
Recognized by Oracle Solaris Scheduler as a thread that should run by it
self on a single core (*)

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

4.
In general, when labeling a cable, the host connection s
hould follow the format: and ____.
Question revoir
(1) Points
<insertion point>
<rack no.>
<cable no.>
<port no.> (*)

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

5.
Which of the statements are correct? Check all that appl
y.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
The T5-8 supports 1, 2, 3, or 4 Compute Modules.
The T5-8 supports 16 HDD or SSDs.
The T5-8 has redundant and hot-swappable fans and power supplies. (*)
The T5-8 has hot-plug disks and PCIe cards. (*)
The T5-8 supports 8 HDD or SSDs. (*)

[Correcte]

Correct!

6.
On a T5-2, what is the name of the bottom disk?
(1) Points

Question revoir

Disk 0 (*)
Disk 1
Disk 8
Disk 6

[Correcte]

Correct!

7.
Which of the following are applicable or characteristic
of a "Hot-Swap" component.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
Typical examples would be PCIe Express modules
Typical examples here are a single RAID disk or a power supplies (*)
refers to an operation where you walk up to the box, yank something out,
replace it, and you are done Refers to an operation where you walk up to the sy
stem, remove the board or component, replace it, and you are done (*)
refers to the ability to perform hot-plug operations, with the additiona
l necessity of some operator actions (invocation of a CLI or actuating a hot ser
vice button on the component to be removed).

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

8.
ilable for SPARC T5?
(1) Points

Which of the following power management features are ava


Question revoir
(Choisir toutes les rponses correctes)

IFS (Intelligent Fan Control) (*)


Coherency Link Scaling (*)

Cycle Skipping (*)


Dynamic Voltage & Frequency Scaling (DVFS) (*)

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

9.
What is the minimum number of installed power supplies t
hat are required if you want to hot-swap a power supply on a SPARC T5-8 server?
Question revoir
(1) Points
4
1
2
3 (*)

[Incorrecte]
tent and try again.

CM slots?
(1) Points

Sorry, that is not correct. Please review the course con

10.
In a T5-8 with two active CMs, what are in the other two
Question revoir

They have to be empty for airflow.


Full CMs with no CPU and no DIMMs
PFM is a Processor Module Filler Board, or Processor Filler Module. (*)
Nothing, they can be empty.

[Correcte]

Correct!

11.
Which of the statements are correct? Check all that apply.
revoir

Question

(1) Points
(Choisir toutes les rponses correctes)
The T5-1B integrates into the Sun Blade 6000 architecture. (*)
The T5-1B features RAID 0, 1 and hot-plug disks. (*)
The T5-1B supports 2x hot-plug PCIe 3.0 x8 Express Modules
The T5-1B supports 2x hot-plug PCIe 2.0 x8 Express Modules (*)
While 32GB DIMMs will work on the blade, only the 16GB DIMM is being qua
lified. (*)

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

12.
Which three options are formal steps in the EIS methodol
ogy?
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
Site audit (*)
Installation configuration planning (*)
System sizing
System test (*)

[Correcte]

Correct!

13.
In order to consolidate the applications on a SPARC T5 s
erver, you require virtual machines that run an independent operating system ins
tance. Which virtualization technology did you select? Question revoir
(1) Points
Dynamic Domains
Oracle VirtualBox

Oracle VM Server for SPARC (*)


Oracle Solaris Containers

[Correcte]

Correct!

14.
Which of the statements are correct? Check all that appl
y.
Question revoir
(1) Points
The T5-4 uses the same SP as the T4-4
The T5-4 uses the same power supply as the T4-4
The T5-4 uses the same PCIe cards as the T4-4
The T5-4 uses the same SP, power supplies, disks, DIMMs and CPU as the T
5-8 (*)
The T5-4 uses the same CMs as the T4-4.

[Correcte]

Correct!
15.

What is out-of-order execution?

Question revoir

(1) Points
A feature of certain operating systems, where programs are executed base
d on the availability of data
A feature of certain processors, where instructions are processed based
on the availability of data (*)
A memory architecture feature, where specific data can be delivered to p
rocessors at the fastest possible rate
A feature of certain multicore processors, where a core can be given pro
cessing priority over other cores

[Correcte]

Correct!

16.
Which of the statements related to the SPARC T5 CPU are correct? Check a
ll that apply. Question revoir
(1) Points
(Choisir toutes les rponses correctes)
BoB = Buffer on Board also known as a Zakim (*)
The T5 has the same number of MCUs as the T4.
The seven coherency links are how the T5 (and M5) are able to talk with
7 other CPUs directly, with no hub. (*)
The on-chip 10GbE was removed. This allowed for the additional cores, me
mory controllers, extra links. (*)
The S3 core is the same used on T4. This means all T4 optimizations also
apply to the T5 (and M4/M5). (*)

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

17.
Question revoir
(1) Points

Which of the following are key features of ILOM

(Choisir toutes les rponses correctes)


System Monitoring and Alert/Fault Management (*)
Power Consumption Management (*)
Firmware Updates (*)
Host Performance Tuning
Manages Interfaces (*)

[Incorrecte]
tent and try again.

ARC T5?

Sorry, that is not correct. Please review the course con

18.
Which of the following are elements of higher RAS for SP
Question revoir

(1) Points
SPARC T5 processor and system architecture
Solaris 11 FMA
I/O and Memory
OVM Hypervisor
All of the above. (*)

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

19.
Which of the statements are correct? Check all that appl
y.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
The T5-8 supports 128 DIMM slots. (*)
The T5-8 CMs and the T5-4 CMs are the same (*)
The T5-8 supports 16 PCIe low-profile cards. (*)
The minimum number of CMs in a T5-8 is 1.
The T5-2 supports 8 PCIe low-profile cards.

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

20.
Which of the statements are correct? Check all that appl
y.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
The T5-4 uses a different Service Processor as the T5-8

The T5-4 uses the same power supplies as the T5-8 (*)
The T5-4 uses the same CM as the T5-8 (*)
The T5-4 supports the same HDD and SSDs as the T5-8 (*)
The T5-4 uses the same fans as the T5-8 (*)

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

21.
Which of the following are Virtualization capabilities of the SPARC T5 s
olution?
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
iPARS
LPARS
Dynamic Domains
Logical Domains (*)
Oracle Solaris Zones (*)

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

22.
During a service call, when replacing the motherboard, h
ow do you preserve the server's original host ID and MAC addreess?
Question
revoir
(1) Points
Back up the service processor configuration details from the old system,
and restore on the new system.
Move the service processor card from the old system to the new system.
Move the System Configuration PROM from the old motherboard to the new m
otherboard. (*)

For security, it is not possible to preserve the server's host ID and MA


C address.

[Correcte]

Correct!

23.
Which of the statements are correct? Check all that appl
y.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
Using a crossbar switch would have allowed for point-to-point communicat
ions, but would have added latency and cost to the server. (*)
The 4-way T3 and T4 used snoopy-based communication between CPUs, but th
is slows performance down for larger 8-way system. (*)
The best design is providing 7 links per CPU so the server could grow to
8-way glueless. (*)
The 8-way architecture can grow to 128 or 256 processors.

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

24.
Which of the following are members of the SPARC T5 famil
y? Check all that apply.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
T5-1B Blade (*)
T5-2 (*)
T5-8 (*)
T5-4 (*)
T5-6

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

25.
What is the primary purpose of the EIS Test Procedure Pl
an?
Question revoir
(1) Points
To generate a test plan and related scripts to be run by the customer to
validate the EIS installation
To confirm that the Explorer Data Collector has been run and analyzed by
the Oracle Risk Analysis System
To capture and agree on the tests that will be applied by the installer
to Oracle products during an EIS installation (*)
To formally document and present the output of the Sun Validation Test S
uite (SunVTS)

[Incorrecte]
tent and try again.

Sorry, that is not correct. Please review the course con

1.
Which of the following are applicable or characteristic of a "Hot-Swap"
component.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
Typical examples would be PCIe Express modules
refers to an operation where you walk up to the box, yank something out,
replace it, and you are done Refers to an operation where you walk up to the sy
stem, remove the board or component, replace it, and you are done (*)
refers to the ability to perform hot-plug operations, with the additiona
l necessity of some operator actions (invocation of a CLI or actuating a hot ser
vice button on the component to be removed).
Typical examples here are a single RAID disk or a power supplies (*)

[Correcte]

y.

Correct!

2.
Which of the statements are correct? Check all that appl
Question revoir

(1) Points
(Choisir toutes les rponses correctes)
The 4-way T3 and T4 used snoopy-based communication between CPUs, but th
is slows performance down for larger 8-way system. (*)
Using a crossbar switch would have allowed for point-to-point communicat
ions, but would have added latency and cost to the server. (*)
The 8-way architecture can grow to 128 or 256 processors.
The best design is providing 7 links per CPU so the server could grow to
8-way glueless. (*)

[Correcte]

Correct!

3.
Which of the statements are correct? Check all that appl
y.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
The T5-8 has hot-plug disks and PCIe cards. (*)
The T5-8 supports 16 HDD or SSDs.
The T5-8 supports 1, 2, 3, or 4 Compute Modules.
The T5-8 supports 8 HDD or SSDs. (*)
The T5-8 has redundant and hot-swappable fans and power supplies. (*)

[Correcte]

Correct!

4.
During a service call, when replacing the motherboard, h
ow do you preserve the server's original host ID and MAC addreess?
Question
revoir
(1) Points
For security, it is not possible to preserve the server's host ID and MA
C address.

Move the System Configuration PROM from the old motherboard to the new m
otherboard. (*)
Back up the service processor configuration details from the old system,
and restore on the new system.
Move the service processor card from the old system to the new system.

[Correcte]

Correct!
5.

ILOM supports which interface capabilities?

Question

revoir
(1) Points
(Choisir toutes les rponses correctes)
IPMI (*)
CLI or Browser (*)
rKVMS (*)
Console Redirection (*)
BlueTooth

[Correcte]

Correct!

6.
Which of the following are applicable or characteristic of a "Hot-Servic
e" component. Question revoir
(1) Points
(Choisir toutes les rponses correctes)
refers to the ability to perform hot-plug operations, with the additiona
l necessity of some operator actions (invocation of a CLI or actuating a hot ser
vice button on the component to be removed) (*)
refers to an operation where you walk up to the box, yank something out,
replace it, and you are done Refers to an operation where you walk up to the sy
stem, remove the board or component, replace it, and you are done
The system will notify the user when it is safe to remove the component
(*)

Typical examples would be PCIe Express modules (*)

[Correcte]

ARC T5?
(1) Points

Correct!
7.
Which of the following are elements of higher RAS for SP
Question revoir

I/O and Memory


OVM Hypervisor
Solaris 11 FMA
All of the above. (*)
SPARC T5 processor and system architecture

[Correcte]

Correct!

8.
Which of the statements are correct? Check all that appl
y.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
The T5-8 CMs and the T5-4 CMs are the same (*)
The T5-8 supports 16 PCIe low-profile cards. (*)
The T5-2 supports 8 PCIe low-profile cards.
The minimum number of CMs in a T5-8 is 1.
The T5-8 supports 128 DIMM slots. (*)

[Correcte]

Correct!
9.

Which of the statements are correct? Check all that appl

y.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
The T5-1B supports 2x hot-plug PCIe 2.0 x8 Express Modules (*)
While 32GB DIMMs will work on the blade, only the 16GB DIMM is being qua
lified. (*)
The T5-1B features RAID 0, 1 and hot-plug disks. (*)
The T5-1B integrates into the Sun Blade 6000 architecture. (*)
The T5-1B supports 2x hot-plug PCIe 3.0 x8 Express Modules

[Correcte]

Correct!

10.
What is the minimum number of installed power supplies t
hat are required if you want to hot-swap a power supply on a SPARC T5-8 server?
Question revoir
(1) Points
3 (*)
2
1
4

[Correcte]

Correct!

What is out-of-order execution?


(1) Points

Question revoir

A memory architecture feature, where specific data can be delivered to p


rocessors at the fastest possible rate
A feature of certain multicore processors, where a core can be given pro
cessing priority over other cores
A feature of certain processors, where instructions are processed based

on the availability of data (*)


A feature of certain operating systems, where programs are executed base
d on the availability of data

[Correcte]

Correct!

12.
Which of the following are members of the SPARC T5 famil
y? Check all that apply.
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
T5-1B Blade (*)
T5-2 (*)
T5-8 (*)
T5-6
T5-4 (*)

[Correcte]

Correct!

13.
Which of the statements related to the SPARC T5 CPU are
correct? Check all that apply. Question revoir
(1) Points
(Choisir toutes les rponses correctes)
The on-chip 10GbE was removed. This allowed for the additional cores, me
mory controllers, extra links. (*)
BoB = Buffer on Board also known as a Zakim (*)
The seven coherency links are how the T5 (and M5) are able to talk with
7 other CPUs directly, with no hub. (*)
The S3 core is the same used on T4. This means all T4 optimizations also
apply to the T5 (and M4/M5). (*)
The T5 has the same number of MCUs as the T4.

[Correcte]

Correct!

14.
Which of the following are Virtualization capabilities o
f the SPARC T5 solution?
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
iPARS
Logical Domains (*)
Oracle Solaris Zones (*)
Dynamic Domains
LPARS

[Correcte]

Correct!
15.

What is Critical Thread Optimization?

Question revoir

(1) Points
Part of the Processor Sets feature of Oracle Solaris that defines a grou
p of logical processors and schedules threads on them
The ability to dynamically alloate core resources among active threads
Recognized by Oracle Solaris Scheduler as a thread that should run by it
self on a single core (*)
The ability to bind individual threads to a processor

[Correcte]

Correct!

16.
What is the primary purpose of the EIS Test Procedure Plan?
revoir
(1) Points

Question

To generate a test plan and related scripts to be run by the customer to


validate the EIS installation

To formally document and present the output of the Sun Validation Test S
uite (SunVTS)
To capture and agree on the tests that will be applied by the installer
to Oracle products during an EIS installation (*)
To confirm that the Explorer Data Collector has been run and analyzed by
the Oracle Risk Analysis System

[Correcte]

Correct!

17.
Which three options are formal steps in the EIS methodol
ogy?
Question revoir
(1) Points
(Choisir toutes les rponses correctes)
System test (*)
Site audit (*)
Installation configuration planning (*)
System sizing

[Correcte]

Correct!

18.
Question revoir
(1) Points

Which of the following are key features of ILOM

(Choisir toutes les rponses correctes)


Firmware Updates (*)
System Monitoring and Alert/Fault Management (*)
Host Performance Tuning
Power Consumption Management (*)

Manages Interfaces (*)

[Correcte]

Correct!

19.
In general, when labeling a cable, the host connection s
hould follow the format: and ____.
Question revoir
(1) Points
<port no.> (*)
<cable no.>
<insertion point>
<rack no.>

[Correcte]

Correct!

20.
Question revoir
(1) Points

On a T5-2, what is the name of the bottom disk?

Disk 1
Disk 6
Disk 0 (*)
Disk 8

[Correcte]

Correct!

21.
Which PCIe slots are available in a T5-4 system with one CM?
revoir
(1) Points
One through fourteen (*)
One through eight
One through fifteen

Question

One through sixteen

[Correcte]

Correct!

22.
ilable for SPARC T5?
(1) Points

Which of the following power management features are ava


Question revoir
(Choisir toutes les rponses correctes)

Dynamic Voltage & Frequency Scaling (DVFS) (*)


Coherency Link Scaling (*)
IFS (Intelligent Fan Control) (*)
Cycle Skipping (*)

[Correcte]

Correct!

23.
Which of the statements are correct? Check all that appl
y.
Question revoir
(1) Points
The T5-4 uses the same power supply as the T4-4
The T5-4 uses the same CMs as the T4-4.
The T5-4 uses the same SP as the T4-4
The T5-4 uses the same PCIe cards as the T4-4
The T5-4 uses the same SP, power supplies, disks, DIMMs and CPU as the T
5-8 (*)

[Correcte]

Correct!

24.
Question revoir
(1) Points

The ____ runs its own embedded operating system.

Oracle ILOM service processor (*)


Hardware Management Pack
OpenBoot PROM
Logical Domains Manager

[Correcte]

Correct!

25.
In order to consolidate the applications on a SPARC T5 s
erver, you require virtual machines that run an independent operating system ins
tance. Which virtualization technology did you select? Question revoir
(1) Points
Dynamic Domains
Oracle VirtualBox
Oracle Solaris Containers
Oracle VM Server for SPARC (*)

[Correcte]

Correct!

You might also like