You are on page 1of 3

SCOPE OF ACCREDITATION

ALS PERU S.A.


Calle 1 Lt-1A Mz-D. Esq. Calle A. Urbanizacin Industrial Bocanegra
Lima, Callao, Per,
CALLAO 01
Accredited Laboratory No. 670
(Conforms with requirements of CAN-P-1579 , CAN-P-4E (ISO/IEC 17025:2005))

CONTACT:
TEL:
FAX:
EMAIL:
URL:

Ms. Milder Mascaraqui


+1 511 574 5700
+1 511 574 0721
Milder.Mascaraqui@alsglobal.com
www.alschemex.com

CLIENTS SERVED:

Mining, Exploration and other interested parties

FIELDS OF TESTING:

Chemical/Physical

PROGRAM SPECIALTY Mineral Analysis


AREA:
ISSUED ON:

2014-01-06

VALID TO:

2018-03-01

The physical sample preparation involving accredited test method for Minerals Analysis as listed on the Scope
of Accreditation may be performed at the ALS Minerals Lima location or at off-site sample preparation
laboratories that are monitored regularly for quality control and quality assurance practices:
ALS Minerals - Calle A Mz C SubLote 2A, Urb.Industrial, Bocanegra, Callao 1 Peru
ALS Minerals - Rua So Paulo, 685, Vespasiano, Minas Gerais 33200 000 Brasil
ALS Minerals - Carrera 48B No. 99, Sur-59, Bodega San Bartolom, Bodega 3, Medellin, Antioquia
Colombia
ALS Minerals - Urb. Industrial El Cairo Manzana A, Lote 3, Distrito de Paucarpata, Arequipa Peru
ALS Minerals - Av. Anhanguera, 15060, Quadra 25, Lote 11E, Setor Santos Dumont, Goinia, Gois
74463-350 Brasil

The approved and most recent version of this document can be viewed on the SCC website at http://palcan.scc.ca/SpecsSearch/GLSearchForm.do

Page 1 of 3

Standards Council of Canada Accredited Laboratory No. 670

METALLIC ORES AND PRODUCTS


Mineral Analysis Testing
Mineral Assaying
ME-XRF12u / ME-XRF12n

AA45
AA46

AA61
AA62

Au/Ag-GRA
Au-AA
ICP81
ME-ICP41

ME-ICP61

ME-MS41

ME-MS61

ME-XRF13u / ME-XRF13n

Analysis of Nickel Laterite Sample by Fusion/XRF


(Al2O3, CaO, Co, Cr2O3, Cu, Fe2O3, K2O, MgO,
MnO, Na2O, Ni, P2O5, Pb, SiO2, TiO2, Zn, Total). Two
method sub-codes, ME-XRF12n for results that are
reported after normalising and ME-XRF12u for results
that are reported un-normalised.
Ag, Cu, Pb and Zn - Determination of Base Metals
Using AAS Following an Aqua Regia Digestion.
Ag, Cu, Pb, Zn and Mo - Determination of Ores and
High Grade Materials Using AAS Following an Aqua
Regia Digestion.
Ag, Mo, Cu, Ni, Pb and Zn - Determination of Base
Metals Using AAS Following a Four Acid Digestion.
Ag, Cu, Mo, Ni, Pb and Zn - Determination of Ores and
High Grade Materials Using AAS Following a Four
Acid Digestion.
Determination of Au and Ag by Lead Collection Fire
Assay and Gravimetric Finish.
Determination of Au by Lead Collection Fire Assay and
Atomic Absorption Spectrometry.
Al, Co, Cu, Fe, Mg, Mn, Ni, Pb, S, and Zn by Sodium
Peroxide Fusion and ICP-AES.
Multi-Element (Ag, Al, As, B, Ba, Be, Bi, Ca, Cd, Co,
Cr, Cu, Fe, Ga, Hg, K, La, Mg, Mn, Mo, Na, Ni, P, Pb,
S, Sb, Sc, Sr, Th, Ti, Tl, U, V, W, Zn) Determination by
Aqua Regia Digestion and ICP-AES.
Multi-Element (Ag, Al, As, Ba, Be, Bi, Ca, Cd, Co, Cr,
Cu, Fe, Ga, K, La, Li, Mg, Mn, Mo, Na, Nb, Ni, P, Pb,
Rb, S, Sb, Sc, Se, Sn, Sr, Ta, Te, Th, Ti, Tl, U, V, W, Y,
Zn, Zr) Determination by 4-Acid Digestion and
ICP-AES.
Multi-Element (Ag, Al, As, B, Ba, Be, Bi, Ca, Cd, Ce,
Co, Cr, Cs, Cu, Fe, Ga, Ge, Hf, Hg, In, K, La, Li, Mg,
Mn, Mo, Na, Nb, Ni, P, Pb, Rb, Re, S, Sb, Sc, Se, Sn, Sr,
Ta, Te, Th, Ti, Tl, U, V, W, Y, Zn, Zr) Determination by
Aqua Regia Digestion and ICP-AES and ICP-MS.
Multi-Element (Ag, Al, As, Ba, Be, Bi, Ca, Cd, Ce, Co,
Cr, Cs, Cu, Fe, Ga, Ge, Hf, In, K, La, Li, Mg, Mn, Mo,
Na, Nb, Ni, P, Pb, Rb, Re, S, Sb, Sc, Se, Si, Sn, Sr, Ta,
Te, Th, Ti, Tl, U, V, W, Y, Zn, Zr) Determination by 4
Acid Digestion and ICP-AES and ICP-MS.
Analysis of Bauxite Samples By Fusion/XRF (Al2O3,
BaO, CaO, Cr2O3, Fe2O3, K2O, MgO, MnO, Na2O,

The approved and most recent version of this document can be viewed on the SCC website at http://palcan.scc.ca/SpecsSearch/GLSearchForm.do

Page 2 of 3

Standards Council of Canada Accredited Laboratory No. 670

ME-XRF21u / ME-XRF21n

ME-XRF24

ME-XRF26

OA-GRA05x
OG46

OG62

PGM-ICP

P2O5, SO3, SiO2, SrO, TiO2, V2O5, Zn, ZrO, Total).


Two method sub-codes, ME-XRF13n for results that are
reported after normalising and ME-XRF13u for results
that are reported un-normalised.
Analysis of Iron Ore samples by Fusion/XRF (Al2O3,
As, Ba, CaO, Cl, Co, Cr2O3, Cu, Fe, K2O, MgO, Mn,
Na2O, Ni, P, Pb, S, SiO2, Sn, Sr, TiO2, V, Zn, Zr,
Total). Two method sub-codes, ME-XRF21n for results
that are reported after normalising and ME-XRF21u for
results that are reported un-normalised.
Analysis of Phosphate by Fusion/XRF (Al2O3, CaO,
Fe2O3, K2O, MgO, MnO2, Na2O, P2O5, SiO2, TiO2,
Total)
Whole Rock Analysis by Fusion/XRF (Al2O3, BaO,
CaO, Cr2O3, Fe2O3, K2O, MgO, MnO, Na2O, P2O5,
SiO2, SrO, TiO2, Total)
Manual Loss On Ignition (LOI) at 1000C for XRF
Methods
Ag, Cu, Mo, Pb and Zn - Determination of Ores and
High Grade Material Using ICP-AES Following an Aqua
Regia Digestion
Ag, Cu, Co, Mo, Ni, Pb and Zn-Determination of Ores
and High Grade Material Using ICP-AES Following a
Four-Acid Digestion
Determination of Au, Pt and Pd by Lead Collection Fire
Assay and ICP-AES.

Chantal Guay, ing., P. Eng.


Vice President, Accreditation
Services
Date: 2014-01-06
Number of Scope Listings: 20
SCC 1003-15/834
Partner File #0
Partner:

The approved and most recent version of this document can be viewed on the SCC website at http://palcan.scc.ca/SpecsSearch/GLSearchForm.do

Page 3 of 3