You are on page 1of 15

System :

3 Phase 4 Wire

Supply Frequency :

50Hz

Panel Name :

Panel No. 1

Panel Type :

Motor Control Center

Incomer Amps :

500A

Power Line Voltage :

415V

Control Voltage :

240V

Your Company Name

TITLE

ELECTRICAL CABINET DRAWINGS

DRG NO.
DWG/2013/01/REV1

B
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
1
15
REV
A

S.No.

Sheet Title

Revision

S.No.

Sheet Title

Revision

S.No.

Cabinet System Details

31

61

List of Drawings

32

62

Control Elements Detail

33

63

Single Line Diagram

34

64

Incomer #1 Metering

35

65

Feeder No. 1, 5KW DOL

36

66

Feeder No. 2, 7KW DOL

37

67

Feeder No. 3, 11KW S/D

38

68

Feeder No. 4, 15KW S/D

39

69

10 Feeder No. 5, 63A FDR.

40

70

11 Feeder No. 6, 63A FDR.

41

71

12 Termination Dwg

42

72

13 General Arrangement - External

43

73

14 General Arrangement - Internal

44

74

15 Bill of Quantity

45

75

16

46

76

17

47

77

18

48

78

19

49

79

20

50

80

21

51

81

22

52

82

23

53

83

24

54

84

25

55

85

26

56

86

27

57

87

28

58

88

29

59

89

30

60

90

Your Company Name

TITLE

Sheet Title

DRG NO.
DWG/2013/01/REV1

LIST OF ALL DRAWINGS


This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

Revision

B
A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
2
15
REV
A

Contactor
NO Contact

Push Button
NO Contact

Timer On-Delay
NO Contact

Neutral Link

Meters

Power Contactor

I>> I>> I>>


Contactor
NC Contact

Push Button
NC Contact

Timer On-Delay
NC Contact

MCB/MCCB/ACB
Single Line Dwg

MCCB/ACB

Overload Relay
X1

M
Contactor
Coil

Indicating Light
ON: Green, Trip: Red
Fwd: Green, Rev: Blue

Timer
Coil

Switch Fuse Unit


Single Line Dwg

SFU

Motor

0 1

I>> I>> I>>


Wire/Cable
Termination

Current
Transformer

Selector Switch
NO Contact

MPCB
Single Line Dwg

Power/Control
Earth

Control
Transformer

Thermostat
NC Contact

Contactor
Single Line Dwg

Sheet Number Reference: XX/YY


XX: Sheet No, YY: Column No.

Your Company Name

TITLE

Capacitor
Single Line Dwg

MPCB

Heater
Single Line Dwg

MCB TP

Ferrul Number Reference: XXYY


XX: Sheet No, YY: Ferrul Number
D

DRG NO.
DWG/2013/01/REV1

ELEMENTS SYMBOLS
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

B
A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
3
15
REV
A

Incoming Cable
(240sqmm Cu)

500A,3P
MCCB

20A
3P MCB

32A
3P MCB

40A 3P
MCCB

63A 3P
MCCB

Cont.

Cont.

Cont.

Cont.

A C 3,9A

A C 3,18A

A C 3,18A

A C 3,18A

OL
6-10A

OL
9-15A

OL
9-15A

OL
9-15A

A 60/5A
4sqmm Cu
Cable

6sqmm Cu
Cable

63A
3P MCB

63A
3P MCB

A 60/5A

6sqmm Cu
Cable

6sqmm Cu
Cable

M1

M2

M3

M4

5KW

7KW

11KW

15KW

35sqmm Cu
Cable

35sqmm Cu
Cable

F1

F2

5KW DOL for

7KW DOL for

11KW Star-Delta for

15KW Star-Delta for

63A Feeder for

63A Feeder for

Feeder No. 1

Feeder No. 2

Feeder No. 3

Feeder No. 4

Feeder No. 5

Feeder No. 6

Your Company Name

TITLE

DRG NO.
DWG/2013/01/REV1

SINGLE LINE DIAGRAM


This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

B
A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
4
15
REV
A

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

Incoming Cable
(240sqmm Cu)
R

Q5.1
500A,3P
MCCB

I>> I>> I>>


R1

Y1

B1

38

39

R1

06/02

Y1

06/02

B1

06/02

N1

06/02

06/14

06/14

40

N1
0503

0502

0501

R1

Y1

Q5.2
2A MCB

2A Fuse

0505

0504

TX5.1
415V/240V

0507
Q5.3
4A MCB

0506

Your Company Name

TITLE

DRG NO.
DWG/2013/01/REV1

Incomer #1 Metering
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

B
A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
5
15
REV
A

05/39

R1

05/39

10

07/02
Y1

05/39

11

12

13

14

15

16

17

05/39

20

21

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

07/13

Q 6.2
2A SP MC B
1A 10

07/02
O L6.1
Trip Ind.

Q6.1
20A
3P MCB

22

07/02
N1

19

05/39

07/02
B1

18

O L6.1
Trip Intlk
1A 12

4
S6.1
Stop
Remote

I>> I>> I>>


1A 13

1A03
1A02

C6.1
MNX9
AC3 9A

S6.2
Stop
Local

1A01

1A 14
1A06
1A05

1A 11

OL6.1
MN2
6-10A

S6.3
Run
Local

1A04

S6.4
Run
Rem.

C 6.1

7
1A09
1A08
1A07

X6

1A 15
1
U1

2
V1

3
W1

M6.1
5KW
Feeder No. 1

H6.1
Trip Ind.

H6.2
Run

C 6.1
Run

05/39

07/13

06/25

Your Company Name

TITLE

5KW DOL for Feeder No. 1

DRG NO.
DWG/2013/01/REV1

B
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
6
15
REV
A

06/09

R1

06/09

10

08/02
Y1

06/09

11

12

13

14

15

16

17

06/09

20

21

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

08/13

Q 7.2
2A SP MC B
1B10

08/02
O L7.1
Trip Ind.

Q7.1
32A
3P MCB

22

08/02
N1

19

06/25

08/02
B1

18

O L7.1
Trip Intlk
1B12

4
S7.1
Stop
Remote

I>> I>> I>>


1B13

1B03
1B02

C7.1
MNX18
AC3 18A

S7.2
Stop
Local

1B01

1B14
1B06
1B05

1B11

OL7.1
MN2
9-15A

S7.3
Run
Local

1B04

S7.4
Run
Rem.

C 7.1

7
1B09
1B08
1B07

X7

1B15
1
U1

2
V1

3
W1

M7.1
7KW
Feeder No. 2

H7.1
Trip Ind.

H7.2
Run

C 7.1
Run

06/25

08/13

07/25

Your Company Name

TITLE

7KW DOL for Feeder No. 2

DRG NO.
DWG/2013/01/REV1

B
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
7
15
REV
A

07/09

R1

07/09

10

11

09/02
Y1

07/09

12

13

14

15

16

17

N1

20

21

A1
A2

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

09/13

O L8.1
Trip Intlk
7
S8.1
Stop
Remote

8S1

C8.1
MNX18
AC3 18A

25

09/02

I>> I>> I>>


8

1C 17

1C13

S8.2
Stop
Local

1C03

60/5A

24

1C 14

1C 16

8S2

23

Q 8.2
2A SP MC B

O L8.1
Trip Ind.

Q8.1
40A,3P
MCCB

22

09/02

07/09

19

07/25

09/02
B1

18

1C02
1C01

1C 18
C8.2

C8.3

1C06

1C12

1C05

1C11

1C04

S8.3
Run
Local

1C 15

1C10

S8.4
Run
Rem.

C 8.1

10

1C 19

1C 19

OL8.1
MN2
9-15A

1C09

T8.1
Star

C 8.2

1C08
1C07

X8

C 8.3

1C 21
1
U1

2
V1

V2

C 8.2

1C 24

6
C 8.2

1C 20

W1

C 8.3

1C 23

1C 22

M8.1
11KW
U2

T8.1
Delta

C 8.1

H8.1
Trip Ind.
W2

1C 25
C 8.3
Star

T8.1

07/25

C 8.1
Main

H8.2
Run

C 8.2
Delta

08/23S
08/30D

08/30 08/25

09/13

08/25
08/28

08/20 08/33
08/23

Feeder No. 3

Your Company Name

TITLE

11KW S/D for Feeder No. 3

DRG NO.
DWG/2013/01/REV1

B
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
8
15
REV
A

08/09

R1

08/09

10

11

10/02
Y1

08/09

12

13

14

15

16

17

N1

20

21

A1
A2

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

10/13

O L9.1
Trip Intlk
7
S9.1
Stop
Remote

9S1

C9.1
MNX18
AC3 18A

25

10/02

I>> I>> I>>


8

1D17

1D13

S9.2
Stop
Local

1D03

60/5A

24

1D14

1D16

9S2

23

Q 9.2
2A SP MC B

O L9.1
Trip Ind.

Q9.1
63A,3P
MCCB

22

10/02

08/09

19

08/25

10/02
B1

18

1D02
1D01

1D18
C9.2

C9.3

1D06

1D12

1D05

1D11

1D04

S9.3
Run
Local

1D15

1D10

S9.4
Run
Rem.

C 9.1

10

1D19

1D19

OL9.1
MN2
9-15A

1D09

T9.1
Star

C 9.2

1D08
1D07

X9

C 9.3

1D21
1
U1

2
V1

V2

C 9.2

1D24

6
C 9.2

1D20

W1

C 9.3

1D23

1D22

M9.1
15KW
U2

T9.1
Delta

C 9.1

H9.1
Trip Ind.
W2

1D25
C 9.3
Star

T9.1

08/25

C 9.1
Main

H9.2
Run

C 9.2
Delta

09/23S
09/30D

09/30 09/25

10/13

09/25
09/28

09/20 09/33
09/23

Feeder No. 4

Your Company Name

TITLE

15KW S/D for Feeder No. 4

DRG NO.
DWG/2013/01/REV1

B
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
9
15
REV
A

09/09

R1

09/09

10

11/02
Y1

09/09

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

09/25

11/13

09/25

11/13

38

39

40

11/02
B1

09/09

Q10.1
63A
3P MCB

11/02
N1

11/02

I>> I>> I>>


1E04
1E03
1E02
1E01

X10

To Feeder No. 5
63A

Your Company Name

TITLE

DRG NO.
DWG/2013/01/REV1

Feeder No. 5
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

B
A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
10
15
REV
A

10/09

10

R1

10/09

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

10/25

10/25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

Y1

10/09

B1

10/09

Q11.1
63A
3P MCB

N1

I>> I>> I>>


1F04
1F03
1F02
1F01

X11

To Feeder No. 6
63A

Your Company Name

TITLE

DRG NO.
DWG/2013/01/REV1

Feeder No. 6
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

B
A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
11
15
REV
A

Your Company Name

TITLE

TERMINATION DIAGRAM PART 1/1

X11 1 2 3 4

1F01
1F02
1F03
1F04

X10 1 2 3 4

1E01
1E02
1E03
1E04

X9 1 2 3 4 5 6 7 8 9 10

1D07
1D08
1D09
1D10
1D11
1D12
1D16
1D17
1D18
1D19

X8 1 2 3 4 5 6 7 8 9 10

1C07
1C08
1C09
1C10
1C11
1C12
1C16
1C17
1C18
1C19

X7 1 2 3 4 5 6 7

1B07
1B08
1B09
1B12
1B13
1B14
1B15

1A07
1A08
1A09
1A12
1A13
1A14
1A15

X6 1 2 3 4 5 6 7

DRG NO.
DWG/2013/01/REV1

B
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
12
15
REV
A

2F 6

1F5(1E)

225

Feeder No. 5, 63A FDR.

ON

OFF

Space Only

375

with 63A 3P MCB


TRIP

1F4(1A)

275
Feeder No. 1, 5KW DOL
with 20A 3P MCB

2F 5

Space Only

275
ON

OFF

TRIP

1F3(1D)

275

Feeder No. 4, 15KW S/D

2F 4

with 63A 3P MCCB

Space Only

275
1700

ON

Cable
Alley

OFF

TRIP

1F2(1C)

Bus Bar
Chamber

Cable
Alley

1775

275

Feeder No. 3, 11KW S/D

2F 3

with 40A 3P MCCB

Space Only

275
1F 1

2F2(1F)

225
Feeder No. 6, 63A FDR.

650

with 63A 3P MCB


ON

OFF

TRIP

2F1(1B)

275
Incomer No. 1
500A 3P MCCB

Feeder No. 2, 7KW DOL

with 32A 3P MCB

75
300

500

Your Company Name

300
1800

400

300
400

TITLE

GENERAL ARRANGEMENT - EXTERNAL

DRG NO.
DWG/2013/01/REV1

B
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
13
15
REV
A

Q10.1

225

375

C6.1

275

Q6.1
OL6. 1

275

275

C9.3

C9.2

C9.1
Q9.1
OL9. 1

Panel Depth
400mm
275

1700

Cable
Alley

Bus Bar
Chamber
275

C8.3

C8.2

Cable
Alley

All Dim. in mm

C8.1
Q8.1
OL8. 1

275

Q11.1

225
650

Q5.1

275

C7.1
Q7.1
OL7. 1

75
300

500

Your Company Name

300
1800

400

300

TITLE

GENERAL ARRANGEMENT - INTERNAL

DRG NO.
DWG/2013/01/REV1

B
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

SHEET
14
15
REV
A

S.No.

Item Description

Make

Qty

S.No.

Item Description

Make

Qty

S.No.

MCCB , 500A 3P

L&T

1 No

31

61

MCCB , 63A 3P

L&T

1 No

32

62

MCB , 63A 3P

L&T

2Nos

33

63

MCCB , 40A 3P

L&T

1 No

34

64

MCB , 32A 3P

L&T

1 No

35

65

MCB , 20A 3P

L&T

1 No

36

66

MCB, 2A DP

L&T

1 No

37

67

MCB, 4A DP

L&T

1 No

38

68

MCB, 2A SP

L&T

4Nos

39

69

10 Contactor 18A, MNX18

L&T

7Nos

40

70

11 Contactor 9A, MNX9

L&T

1 No

41

71

12 Star Delta Timer

L&T

2Nos

42

72

13 Neutral Link

Reputed

3Nos

43

73

14 O/L MN2, 9-15A

L&T

3Nos

44

74

15 O/L MN2, 6-10A

L&T

1 No

45

75

16 CT 60/5A

Conzerv

2Nos

46

76

17 Ammeter

Conzerv

2Nos

47

77

18 Fuse with Fuse Base 2A

L&T

3Nos

48

78

19 Control TX 415/240V

Reputed

1 No

49

79

20 Ind Light Red, 240VAC

Teknik

5Nos

50

80

21 Ind Light Yellow, 240VAC

Teknik

1 No

51

81

22 Ind Light Blue, 240VAC

Teknik

1 No

52

82

23 Lum. P.B. (Green) with 1NO

Teknik

4Nos

53

83

24 Stand. P.B. (Red) with 1NC

Teknik

4Nos

54

84

25

55

85

26

56

86

27

57

87

28

58

88

29

59

89

30

60

90

Your Company Name

TITLE

Item Description

DRG NO.
DWG/2013/01/REV1

BILL OF QUANTITY
This drawing is submitted only for confidential use. It may not be copied, printed
or submitted to third parties without prior permission of Your Company Name

Make

B
A
REV

10.05.15
DATE

DRA WINGS BUILT


MO DIF IC ATIO N

Author Name

DRA WN

USER
C HEC KED

CUSTOMER
Your Customer Name

Qty

SHEET
15
15
REV
A

You might also like