You are on page 1of 119

www.accepta.

com

Table of Contents
Section

Details

Page

2.0 : General Information

2.1 - 2.4 Accepta Ltd. Details, Services & Ordering.

3.0 : Test Method Selector

3.0 Test Parameter / Method Selector

4.0 : Test Kits

4.1 Comprehensive Engineer Test Kit (Various versions)


4.2 Cooling (Open & Closed) (Standard & Backpack versions)
4.3 Closed Water Systems
4.4 Chlorination
4.5 Boiler Water
4.6 Legionella Compliance
4.7 Ion Exchange Resin Kit
4.8 Manual Silt Density Index

8
23
27
28
29
31
33
34

5.0 : Pocket Test Meters

5.1 PH1 - pH/Temperature Meter


5.2 EC1 - Condy/TDS/Temp/Salinity Meter
5.3 PH100 - Extech pH/Temperature Meter
5.4 EC400 - Extech Condy/TDS/Temp/Salinity Meter
5.5 EC500 - Extech Combined pH/Condy/TDS/Temp Meter
5.6 CL200 - Extech Total Chlorine/Temperature Meter
5.7 DO600 - Extech Oxygen/Temperature Meter
5.8 RE300 - Extech Redox (ORP) /Temperature Meter
5.9 RefG300 - Glycol Refractometer

36
37
38
39
40
41
42
43
44

6.0 : Professional Test Meters

6.1 Martini MI806 - 4 in 1 pH/Conductivity/TDS/Temp Meter


6.2 Eutech pH 11 - pH Meter
6.3 Eutech Con 11 - Conductivity Meter
6.4 Eutech PC300 - Combined pH/ Condy/TDS/Temp Meter
6.5 Jenway 350 - pH Meter
6.6 Jenway 470 - Conductivity/TDS/Temp Meter
6.7 Jenway 430 - Combined pH/ Conductivity/TDS/Temp Meter
6.8 TRANSEC - Conductivity/TDS/Salinity/Temp Meter
6.9 TRANSPH - pH/ORP Meter
6.10 Borescope

46
47
48
49
50
51
52
53
54
55

7.0 : Drop Test Kits

7.1 Drop Test Kits - Acidity to Zinc

57

8.0 : MiniKits

8.1 MiniKits - Acidity to Zinc

64

9.0 : Comparator Kits

9.1 Comparators - Aluminium to Zinc

67

10.0 : Titration Test System

10.1 Titration Cartridge Tests - Alkalinity to Zinc

74

11.0 : Test Strips

11.1 Test Strips - Ammonia to Zinc with many pH ranges

77

12.0 : Bacteria Testing

12.1 Oxidising Kits (Extech pen)


12.2 Non Oxidising Kits (Isothiazolone etc)
12.3 ATP Meter & Swabs
12.4 Dipslides & NRB/SRB Tube Tests
12.5 Incubators
12.6 Universal Rapid Legionella Test Kit
12.7 Dip-slide Comparator App

80
81
82
83
84
85
86

13.0 : Corrosion Coupons

13.1 Corrosion Coupons & Test Racks

88

14.0 : PrimeLab Photometer

14.1 PrimeLab (Single or Multi Range) Photometer


14.2 Parameters & Reagents

90
92

15.0 : Temperature Meters

15.1 - 15.4 Temperature Meters

102

16.0 : Equipment

16.1 Equipment & Components

107

17.0 : Reagents

17.1 Reagents Available

110

www.accepta.com

Section 2.0
2.1 Company Information
Accepta
Statham House
Talbot Road
Manchester M32 0FP
United Kingdom
Tel :
Fax :
Email :

+44 (0) 161 977 2334


+44 (0) 870 135 6389
info@accepta.com

2.2 Laboratory & Support Services


Our extensive laboratory is able to offer a wide range of services which include:

Full system water analysis


Deposit analysis.
Corrosion coupon weighing.
Determination of product factors for tests like Phosphonate, Nitrite, Molybdate etc.
Calibration services on an extensive range of meters.

2.3 Training Services


With many years experience in the water treatment and testing market we are highly trained in advising clients in the use and application of test kits and reagents.
We offer specific training in the use of test kits and the various test options available.
Training can be carried out at our offices/laboratory or can be offered on site and the training can
be tailored to suit your application and requirements and a wide range of subjects can be covered.

2.4 Ordering & Terms


Orders can be accepted by the following methods or via our on line portal.
Email:

orders@accepta.com

Phone: +44 (0) 161 877 2334 (e-mail confirmation is required on all telephone orders)
Fax:

+44 (0) 870 135 6389

General
1) Prices, where quoted are exclusive of VAT and delivery.
2) For Terms & Conditions of Sale, please refer to our website www.accepta.com/terms-conditions
3) Orders received will generally be dispatched within 2 working days.
4) A standard delivery charge will apply on all orders.
5) The delivery charge for dip slides and/or large test kits and reagent orders will be dependant on
the weight of the goods, please ask for a quote for delivery charges.
6) The shelf life of most reagents is greater than 2 years when stored in correct conditions. Please
refer to the relevant reagent Safety Data Sheet (SDS) for full details.
7) All reagents and kits can be branded with your own logo, please contact us for details.
8) Product SDS sheets are available own branded and in many languages, please ask for details.
9) All electronic equipment is warranted for 12 months from date of dispatch.
10) Probes for pH, Conductivity and other meters are warranted for 6 months from date of dispatch.
11) Returns must be notified in writing within 48 hours of receipt of goods.
12) All payments are due within 30 days from date of invoice.
13) If an invoice remains unpaid after our agreed payment terms, we reserve the right to forward the
invoice to a debt collection agency which will incur an additional 20% surcharge.
14) Some images of test kits and components shown in the catalogue may differ from the actual
goods supplied due to stock availability.

www.accepta.com

Section 3.0
Test Method Selector
This useful selector can be used to help identify the test methods we have available for those
parameters you wish to monitor. Simply select the parameter from the left column, then work across
to identify which test methods are available. If you need help identifying the most appropriate test
method for your application please contact Acceptas technical team.
Parameter

PrimeLab

Drop Test

Titration Comparator Powder Pillow


Tests
Equivalents

Test
Meters

Acidity
Active Oxygen

Alkalinity

Aluminium

Amine

Ammonia

Anionic
Boron

Bromine

Carbohydrazide

Chelant
Chloride

Chloramines

Chlorine (TS)

Chlorine Dioxide (TS)

Chlorite

Chromium

COD (LR, MR & HR)

Colour

Requires heater block

Conductivity/TDS
Copper (TS)

Cyanuric Acid

DEHA

DBNPA

Fluoride

Glutaraldehyde

Biocide Kit

Biocide Kit

Hardness, Stop/Go
Hardness, Total (TS)

Glycol (PEG/MEG)
Hardness, Calcium

www.accepta.com

Section 3.0
Test Method Selector (continued)
Parameter

PrimeLab

Hydrazine

Hydroquinone

Hydrogen Peroxide
(TS)

Iodine

Iron (TS)

Drop Test

Titration Comparator Powder Pillow Test


Tests
Equivalents Meters

Isothiazalone

Biocide Kit

Magnesium

Manganese (TS)

Molybdate

Nickel

Nitrate

Nitrite

Ozone

Peracetic Acid (TS)


pH (TS)

Phenol

PHMB

Phosphate

Phosphonate

Polyacrylate

Polyamine

Polymers

Potassium (TS)

QAC

Silver
Sodium
Hypochlorite

Sulphate

Sulphide

Sulphite

Suspended Solids

Silica

Tannin

www.accepta.com

Section 3.0
Test Method Selector (continued)
Parameter

PrimeLab

THPS

Drop Test

Titration Comparator Powder Pillow Test


Tests
Equivalents Meters

Biocide Kit

Total Oxidant

Triazole

Turbidity

Zinc

Note: Parameters above with a (TS) denotes where Test Strips are available as an alternative testing
method.
IF THE PARAMETER YOU ARE INTERESTED IN IS NOT LISTED, PLEASE CONTACT US

www.accepta.com

Section 4.0
Test Kits

www.accepta.com

Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P
Acceptas Eng3005P comprehensive combined test kit is based on
photometer and titration gun chemistries and has been developed
as a complete kit, specifically for water treatment professionals
involved with the maintenance and management of boiler, cooling
water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all
the equipment and reagents necessary to effectively test and monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are achieved and maintained.
This test kit includes the following:

Contents

Range

Code

Aluminium Case complete with foam & white testing board

Eq5026

Waterproof Instructions

Eq5084

1 x 20ml Luer Lock Syringe

Eq5075

1 x 10ml Luer Lock Syringe

Eq5073

1 x 5ml Standard Syringe

Eq5077

1 x 1ml Standard Syringe

Eq5074

1 x Filter Holder 25mm

Eq5044

1 x Filter Paper 25mm GF/C (50pk)

Eq5048

1 x Filter Paper 25mm 0.45 micron (50pk)

Eq5061

1 x 125ml Plastic Test Bottle

Eq5008

4 x 65ml Plastic Test Bottle

Eq5018

1 x 5/10ml Tube

Eq5015

1 x 250ml Washer Bottle

Eq5082

Jenway 430 Combined pH/Conductivity/TDS & Temp Meter

Eq5119

PrimeLab Photometer

Plp1001

10ml Glass Cells for PrimeLab Photometer (6)

Pla1100

Alkalinity P (Titration)

0 - 2000

PA1 (65ml)

Dt1001

Alkalinity cartridge (2 x 20ml for all Alkalinities)

Crt91002

Alkalinity M (Titration)

0 - 2000

TA4 (65ml)

Dt1004

Alkalinity OH (Titration)

0 - 2000

PA3 (65ml)

Dt1007

www.accepta.com

Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P (continued)
Contents

Range

Bromine (PrimeLab)

0.05 - 18

Code

PL DPD 1 A (30ml)

Plr1102

PL DPD 1 B (30ml)

Plr1103

PL DPD Nitrite Powder (20g)

Plr1104

Chloride (Titration)

0 - 2000

BC1/CC1 (65ml)

Dt1023

Chloride Cartridge (2 x 20ml)

Crt91003

Chlorine (PrimeLab)

0.01 - 8

PL DPD 3 C (30ml) (also requires PL DPD 1 A & B)


Chlorine Dioxide (PrimeLab)

Plr1104
0.02 - 15

PL DPD Glycine (30ml) (also requires PL DPD 1 A & B)


Hardness, Total (Titration)

Plr1106
0 - 2000

TH2 (65ml)

Dt1046

TH5 (65ml)

Dt1047

Hardness Cartridge HR (2 x 20ml for all Hardness)

Crt91007

Hardness, Calcium (Titration)

0 - 2000

CH2 (65ml)

Dt1043

CH1P (20g)

Dt1050

Hardness, Stop/Go (Drop Test)

0-4

Hardness Stop/Go Solution (65ml)


Iron Soluble & Total (PrimeLab)

Dt1129
0 - 30

PL Iron HR 1 (65ml)

Plr1119

PL Iron HR 2 (30ml)

Plr1120

Molybdate HR (PrimeLab)

5 - 200 (with dilution 50 - 2000)

PL Molybdate 1 (65ml)

Plr1139

Nitrite (PrimeLab)

0 - 3000

PL Nitrite HR 2 (65ml)

Dt1072

Phosphate HR (PrimeLab)

0 - 100

PL Phosphate HR 1 (65ml)

Plr1145

PL Phosphate HR 2 (65ml)

Plr1146

Phosphonate (PrimeLab)

0 - 20

PL Phosphonate 1 (20g)

Plr1169

PL Phosphonate 2 (20g)

Plr1170

PL Phosphonate 3 (65ml)

Plr1171

PL Phosphonate 4 (20g)

Plr1172

www.accepta.com

Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P (continued)
Contents

Range

Sulphite (PrimeLab)

5 - 50

Code

PL Sulphite HR 1 Tablets (50pk)

Plr1203

PL Sulphite HR 2 Tablets (50pk)

Plr1204

Tannin (PrimeLab)

0 - 300

PL Tannin 1 (65ml)

Plr1176

PL Tannin 2 (30ml)

Plr1177

Calibration Solutions for Jenway 430 Meter


Standard Conductivity 12.88mS (65ml)

Dt1154

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

20% Acetic Acid (65ml)

Dt1103

Refractometer (PEG & MEG)

0 - 60%

RefG300

1 x Digital Titrator (For Titration complete with bracket)

Eq5022

6 x Titrator Accessory Pack

Eq5023

www.accepta.com

10

Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P/DT
Acceptas Eng3005P/DT comprehensive combined test kit is
based on photometer and drop test chemistries and has been developed as a complete kit, specifically for water treatment professionals
involved with the maintenance and management of boiler, cooling water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all
the equipment and reagents necessary to effectively test and monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are achieved and maintained.
This test kit includes the following:

Contents

Range

Code

Aluminium Case complete with foam & white testing board

Eq5026

Waterproof Instructions

Eq5084

1 x 20ml Luer Lock Syringe

Eq5075

1 x 10ml Luer Lock Syringe

Eq5073

1 x 5ml Standard Syringe

Eq5077

1 x 1ml Standard Syringe

Eq5074

1 x Filter Holder 25mm

Eq5044

1 x Filter Paper 25mm GF/C (50pk)

Eq5048

1 x Filter Paper 25mm 0.45 micron (50pk)

Eq5061

1 x 125ml Plastic Test Bottle

Eq5008

4 x 65ml Plastic Test Bottle

Eq5018

1 x 5/10ml Tube

Eq5015

1 x 250ml Washer Bottle

Eq5082

Jenway 430 Combined pH/Conductivity/TDS & Temp Meter

Eq5119

PrimeLab Photometer

Plp1001

10ml Glass Cells for PrimeLab Photometer (6)

Pla1100

Alkalinity P (Drop Test)

5 - 2400

PA1 (65ml)

Dt1001

PA2/TA2 (65ml)

Dt1005

TA3 (65ml)

Dt1006

Alkalinity M (Drop Test)

5 - 2400

TA4 (65ml) (also requires PA2/TA2 & TA3)


Alkalinity OH (Drop Test)

Dt1004
5 - 2400

PA3 (65ml) (also requires PA1, PA2/TA2 & TA3)

www.accepta.com

Dt1007

11

Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P/DT
Contents

Range

Bromine (PrimeLab)

0.05 - 18

Code

PL DPD 1 A (30ml)

Plr1102

PL DPD 1 B (30ml)

Plr1103

PL DPD Nitrite Powder (20g)

Plr1104

Chloride (Drop Test)

0 - 3000

BC1/CC1 (65ml)

Dt1023

BC2 (65ml)

Dt1026

CC2 (65ml)

Dt1024

Chlorine (PrimeLab)

0.01 - 8

PL DPD 3 C (30ml) (also requires PL DPD 1 A & B)


Chlorine Dioxide (PrimeLab)

Plr1104
0.02 - 15

PL DPD Glycine (30ml) (also requires PL DPD 1 A & B)


Hardness, Total (Drop Test)

Plr1106
5 - 1200

TH2 (65ml)

Dt1046

TH3 (65ml)

Dt1044

H/TH4/CH3 (65ml)

Dt1049

TH5 (65ml)

Dt1047

Hardness, Calcium (Drop Test)

5 - 1200

CH2 (65ml)

Dt1043

CH1P (20g) (also require TH3 & H/TH4/CH3)

Dt1050

Hardness, Stop/Go (Drop Test)

0-4

Hardness Stop/Go Solution (65ml)


Iron Soluble & Total (PrimeLab)

Dt1129
0 - 30

PL Iron HR 1 (65ml)

Plr1119

PL Iron HR 2 (30ml)

Plr1120

Molybdate HR (PrimeLab)

5 - 200 (with dilution 50 - 2000)

PL Molybdate 1 (65ml)

Plr1139

Nitrite (PrimeLab)

0 - 3000

PL Nitrite HR 2 (65ml)

Dt1072

Phosphate HR (PrimeLab)

0 - 100

PL Phosphate HR 1 (65ml)

Plr1145

PL Phosphate HR 2 (65ml)

Plr1146

Phosphonate (PrimeLab)

0 - 20

PL Phosphonate 1 (20g)

Plr1169

PL Phosphonate 2 (20g)

Plr1170

PL Phosphonate 3 (65ml)

Plr1171

PL Phosphonate 4 (20g)

Plr1172

www.accepta.com

12

Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P/DT
Contents

Range

Sulphite (PrimeLab)

5 - 50

Code

PL Sulphite HR 1 Tablets (50pk)

Plr1203

PL Sulphite HR 2 Tablets (50pk)

Plr1204

Tannin (PrimeLab)

0 - 300

PL Tannin 1 (65ml)

Plr1176

PL Tannin 2 (30ml)

Plr1177

Calibration Solutions for Jenway 430 Meter


Standard Conductivity 12.88mS (65ml)

Dt1154

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

20% Acetic Acid (65ml)

Dt1103

Refractometer (PEG & MEG)

0 - 60%

www.accepta.com

RefG300

13

Section 4.1
Comprehensive Engineers Test Kit - Eng3005
Acceptas Eng3005 comprehensive combined test kit is based on
titration gun & comparator chemistries and has been developed as
a complete kit, specifically for water treatment professionals
involved with the maintenance and management of boiler, cooling
water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all the equipment and reagents necessary to effectively test and
monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are
achieved and maintained.

Contents

Range

Code

Aluminium Case complete with foam & white testing board

Eq5026

Waterproof Instructions

Eq5084

1 x 20ml Luer Lock Syringe

Eq5075

1 x 10ml Luer Lock Syringe

Eq5073

1 x 5ml Standard Syringe

Eq5077

1 x 1ml Standard Syringe

Eq5074

1 x Filter Holder 25mm

Eq5044

1 x Filter Paper 25mm GF/C (50pk)

Eq5048

1 x Filter Paper 25mm 0.45 micron (50pk)

Eq5061

1 x 125ml Plastic Test Bottle

Eq5008

4 x 65ml Plastic Test Bottle

Eq5018

1 x Plastic Comparator

Eq5085

4 x 10ml Comparator Cells

Eq5006

1 x 5/10ml Tube

Eq5015

1 x 250ml Washer Bottle

Eq5082

Jenway 430 Combined pH/Conductivity/TDS & Temp Meter

Eq5119

Alkalinity P (Titration)

0 - 2000

PA1 (65ml)

Dt1001

Alkalinity Cartridge (2 x 20ml for all Alkalinities)

Crt91002

Alkalinity M (Titration)

0 - 2000

TA4 (65ml)

Dt1004

Alkalinity OH (Titration)

0 - 2000

PA3 (65ml) (also requires PA1)

Dt1007

www.accepta.com

14

Section 4.1
Comprehensive Engineers Test Kit - Eng3005 (continued)
Contents

Range

Bromine (Comparator)

0-5

Code

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD Nitrite Powder (20g)

Dt1295

Chloride (Titration)

0 - 2000

BC1/CC1 (65ml)

Dt1023

Chloride Cartridge (2 x 20ml)

Crt91003

Chlorine (Comparator)

0-4

DPD No3 Solution C (30ml) (also requires DPD 1 A & B)


Iron LR (Comparator)

Dt1507
0-1

Fe5 (65ml)

Dt1110

Sulphuric Acid 50% (65ml)

Dt1155

Iron HR (Comparator)

0.5 - 10

Fe10 (65ml) (also requires Sulphuric Acid 50%)


Hardness, Total (Titration)

Dt1247
0 - 2000

TH2 (65ml)

Dt1046

TH5 (65ml)

Dt1047

Hardness Cartridge HR (2 x 20ml for all Hardness)

Crt91007

Hardness, Calcium (Titration)

0 - 2000

CH2 (65ml)

Dt1043

CH1P (20g)

Dt1050

Hardness, Stop/Go (Drop Test)

0-4

Hardness Stop/Go Solution (65ml)


Molybdate VHR (Comparator)

Dt1129
0 - 500

Molybdate HR (65ml)

Dt1127

Nitrite (Titration)

0 - 2000

N1 (65ml) (also requires Sulphuric Acid 50%)

Dt1072

Nitrite Cartridge (2 x 20ml)

Crt91009

Phosphonate (Titration)

0 - 20

P1/2 (65ml)

Dt1514

P3 (65ml)

Dt1080

P4L (65ml)

Dt1291

Phosphonate Cartridge (2 x 20ml)

Crt91004

Phosphate HR (Comparator)

0 - 80

PB1 (65ml)

Dt1111

PB2 (65ml)

Dt1112

www.accepta.com

15

Section 4.1
Comprehensive Engineers Test Kit - Eng3005 (continued)
Contents

Range

Sulphite (Titration)

0 - 100

Code

S1 (40g)

Dt1092

Sulphite Cartridge (2 x 20ml)

Crt91005

Tannin (Drop Test)

0 - 300

TN1 (40g)

Dt1094

TN2 (65ml)

Dt1095

Calibration Solutions for Jenway 430 Meter


Standard Conductivity 12.88mS (65ml)

Dt1154

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

20% Acetic Acid (65ml)

Dt1103

Refractometer (PEG & MEG)

0 - 60%

RefG300

1 x Digital Titrator (For Titration complete with bracket)

Eq5022

6 x Titrator Accessory Pack

Eq5023

www.accepta.com

16

Section 4.1
Engineers Test Kit with Titration Syringe - Eng3005TS
Acceptas Eng3005TS comprehensive combined test kit is based
on titration syringe & comparator chemistries and has been developed as a complete kit, specifically for water treatment professionals involved with the maintenance and management of boiler,
cooling water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all the equipment and reagents necessary to effectively test and
monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are
achieved and maintained.
This test kit includes the following:

Contents

Range

Code

Aluminium Case complete with foam & white testing board

Eq5026

Waterproof Instructions

Eq5084

1 x 20ml Luer Lock Syringe

Eq5075

1 x 10ml Luer Lock Syringe

Eq5073

1 x 5ml Standard Syringe

Eq5077

1 x 1ml Standard Syringe

Eq5074

1 x Filter Holder 25mm

Eq5044

1 x Filter Paper GF/C (50pk)

Eq5048

1 x Filter Paper 25mm 0.45 micron (50pk)

Eq5061

1 x 125ml Plastic Test Bottle

Eq5008

4 x 65ml Plastic Test Bottle

Eq5018

1 x Plastic Comparator

Eq5085

4 x 10ml Comparator Cells

Eq5006

1 x 5/10ml Tube

Eq5015

1 x 250ml Washer Bottle

Eq5082

Jenway 430 Combined pH/Conductivity/TDS & Temp Meter

Eq5119

Alkalinity P (Titration)

0 - 2000

PA1 (65ml)

Dt1001

Alkalinity cartridge (2 x 20ml for all Alkalinities)

Crt91002

Alkalinity M (Titration)

0 - 2000

TA4 (65ml)

Dt1004

Alkalinity OH (Titration)

0 - 2000

PA3 (65ml)

Dt1007

www.accepta.com

17

Section 4.1
Engineers Test Kit with Titration Syringe - Eng3005TS
(continued)
Contents

Range

Bromine (Comparator)

0-5

Code

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD Nitrite Powder (20g)

Dt1295

Chloride (Titration)

0 - 2000

BC1/CC1 (65ml)

Dt1023

Chloride Cartridge (2 x 20ml)

Crt91003

Chlorine (Comparator)

0-4

DPD No3 Solution C (30ml) (also requires DPD 1 A & B)


Hardness Total (Titration)

Dt1507
0 - 2000

TH2 (65ml)

Dt1046

TH5 (65ml)

Dt1047

Hardness Cartridge HR (2 x 20ml for all Hardness)

Crt91007

Hardness Calcium (Titration)

0 - 2000

CH2 (65ml)

Dt1043

CH1P (20g)

Dt1050

Hardness Stop/Go (Drop Test)

0-4

Hardness Stop/Go Solution (65ml)


Iron Soluble & Total LR (Comparator)

Dt1129
0-1

FE5 (65ml)

Dt1110

Sulphuric Acid 50% (65ml)

Dt1155

Molybdate VHR (Comparator)

0 - 500

Molybdate HR (65ml)

Dt1127

Nitrite (Titration)

0 - 2000

N1 (65ml) (also requires Sulphuric Acid 50%)

Dt1072

Nitrite Cartridge (2 x 20ml)

Crt91009

Phosphonate (Titration)

0 - 20

P1/2 (65ml)

Dt1514

P3 (65ml)

Dt1080

P4L (65ml)

Dt1291

Phosphonate cartridge (2 x 20ml)

Crt91004

Phosphate HR (Comparator)

0 - 80

PB1 (65ml)

Dt11111

PB2 (65ml)

Dt1112

www.accepta.com

18

Section 4.1
Engineers Test Kit with Titration Syringe - Eng3005TS
(continued)
Contents

Range

Sulphite (Titration)

0 - 100

Code

S1 (40g)

Dt1092

Sulphite Cartridge (2 x 20ml)

Crt91005

Tannin (Drop test)

10 - 300

TN1 (40g)

Dt1094

TN2 (65ml)

Dt1095

Calibration Solutions for Jenway 430 Meter


Standard Conductivity 12.88mS (65ml)

Dt1154

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

20% Acetic Acid (65ml)

Dt1103

Refractometer (PEG & MEG)

0 - 60%

6 x Titrator Accessory Pack

RefG300
Eq5023

www.accepta.com

19

Section 4.1
Engineers Test Kit with Drop Tests - Eng3005DT
Acceptas Eng3005DT comprehensive combined test kit is based
on photometer and titration gun chemistries and has been developed as a complete kit, specifically for water treatment professionals involved with the maintenance and management of boiler, cooling water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all
the equipment and reagents necessary to effectively test and monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are achieved and maintained.
This test kit includes the following:

Contents

Range

Code

Aluminium Case complete with foam & white testing board

Eq5026

Waterproof Instructions

Eq5084

1 x 20ml Luer Lock Syringe

Eq5075

1 x 10ml Luer Lock Syringe

Eq5073

1 x 5ml Standard Syringe

Eq5077

1 x 1ml Standard Syringe

Eq5074

1 x Filter Holder 25mm

Eq5044

1 x Filter Paper GF/C (50pk)

Eq5048

1 x Filter Paper 25mm 0.45 micron (50pk)

Eq5061

1 x 125ml Plastic Test Bottle

Eq5008

4 x 65ml Plastic Test Bottle

Eq5018

1 x Plastic Comparator

Eq5085

4 x 10ml Comparator Cells

Eq5006

1 x 5/10ml Tube

Eq5015

1 x 250ml Washer Bottle

Eq5082

EC500 Combined pH/Conductivity/TDS/Temp/Salinity Meter

EC500

Alkalinity P (Drop Test)

5 - 2400

PA1 (65ml)

Dt1001

PA2/TA2 (65ml)

Dt1005

TA3 (65ml)

Dt1006

Alkalinity M (Drop Test)

5 - 2400

TA4 (65ml) (also requires PA2/TA2 & TA3)

www.accepta.com

Dt1004

20

Section 4.1
Engineers Test Kit with Drop Tests - Eng3005DT
Contents

Range

Alkalinity OH (Drop Test)

5 - 2400

PA3 (65ml) (also requires PA1, PA2/TA2 & TA3)


Bromine (Comparator)

Code

Dt1006
0-5

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD Nitrite Powder (20g)

Dt1295

Chloride (Drop Test)

0 - 3000

BC1/CC1 (65ml)

Dt1023

BC2 (65ml)

Dt1026

CC2 (65ml)

Dt1024

Chlorine (Comparator)

0-4

DPD No3 Solution C (30ml) (also requires DPD 1 A & B)


Hardness, Total (Drop Test)

Dt1507
5 - 1200

TH2 (65ml)

Dt1046

H/TH4/CH3 (65ml)

Dt1049

TH5 (65ml)

Dt1047

TH3 (65ml)

Dt1044

Hardness, Calcium (Drop Test)

5 - 1200

CH2 (65ml)

Dt1043

CH1P (20g) (also requires H/TH4/CH3 & TH3)

Dt1050

Hardness, Stop/Go (Drop Test)

0-4

Hardness Stop/Go Solution (65ml)


Iron LR (Comparator)

Dt1129
0-1

FE5 (65ml)

Dt1110

Sulphuric Acid 50% (65ml)

Dt1155

Iron HR (Comparator)

0.5 - 10

FE10 (65ml) (also requires Sulphuric Acid 50%)


Molybdate VHR (Comparator)

Dt1247
0 - 500

Molybdate HR (65ml)

Dt1127

Nitrite (Drop Test)

0-2000

N1 (65ml)

Dt1072

N2 (65ml)

Dt1073

Phosphonate (Drop Test)

0 - 20

P1/2 (65ml)

Dt1514

P3 (65ml)

Dt1080

P4L (65ml)

Dt1291

P5 (65ml)

Dt1075

www.accepta.com

21

Section 4.1
Engineers Test Kit with Drop Tests - Eng3005DT
Contents

Range

Phosphate (Comparator)

0-80

Code

PB1 (65ml)

Dt1111

PB2 (65ml)

Dt1112

Sulphite (Drop Test)

5 - 300

S1 (40g)

Dt1092

S2 (65ml)

Dt1093

Tannin (Drop Test)

10-300

TN1 (40g)

Dt1094

TN2 (65ml)

Dt1095

Calibration Solutions for Extech EC500 Meter


Standard Conductivity 1413S (65ml)

Dt1109

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

20% Acetic Acid (65ml)

Dt1103

Refractometer (PEG & MEG)

0-60%

www.accepta.com

RefG300

22

Section 4.2
Cooling (Open & Closed) Water Test Kit - Cool3002
Acceptas Cool3002 comprehensive Cooling (Open & Closed)
Water Test Kit is based on drop test and colour comparator
chemistries and has been developed specifically for engineers
and water treatment professionals involved with the maintenance and management of both open and closed cooling systems to
ensure optimum operating conditions.
Cooling water systems require careful test monitoring to ensure
the correct water conditions are maintained at all times. Failure
to maintain correct treatment programs can lead to serious
problems including reduced efficiency, the build-up of scale,
potentially damaging corrosive water conditions and increased
microbiological activity, which may include the growth of
Legionella bacteria. Replacements and components are
available, please refer to replacement reagent section.
The Cooling (Open & Closed) Water test kit is presented in its
own robust case and includes all the equipment and reagents necessary to effectively test and monitor system waters.

Contents

Range

Code

2019 Maxi Case with Foams

Eq5027

Waterproof instructions

Eq5084

1 x 20ml Luer Lock Syringe

Eq5075

1 x 10ml Luer Lock Syringe

Eq5073

1 x Filter Holder 25mm

Eq5044

1 x Filter Papers GF/C (50pk)

Eq5048

1 x Filter Paper 25mm 0.45 micron (50pk)

Eq5061

2 x 65ml Plastic Test Bottle

Eq5018

1 x Plastic Comparator

Eq5085

2 x 10ml Comparator Cells

Eq5006

1 x 5/10ml Tube

Eq5015

PH1 - pH/Temperature Meter

0 - 14

pH1

EC1 - Conductivity/TDS/Temperature Meter

0 - 20.00 mS

EC1

Alkalinity M (Drop Test)

5 - 2400

TA4 (65ml)

Dt1004

PA2/TA2 (65ml)

Dt1005

TA3 (65ml)

Dt1006

Bromine (Comparator)

0-5

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD Nitrite Powder (20g)

Dt1295

Chloride (Drop Test)

0 - 3000

BC1/CC1 (65ml)

Dt1023

BC2 (65ml)

Dt1026

CC2 (65ml)

Dt1024

www.accepta.com

23

Section 4.2
Cooling (Open & Closed) Test Kit - Cool3002 (continued)
Contents

Range

Hardness, Calcium (Drop Test)

5 - 1200

Code

CH2 (65ml)

Dt1043

CH1P (20g) (also requires TH3 & H/TH4/CH3)

Dt1050

Hardness, Total (Drop Test)

5 - 1200

TH2 (65ml)

Dt1046

H/TH4/CH3 (65ml)

Dt1049

TH5 (65ml)

Dt1047

TH3 (65ml)

Dt1044

Hardness, Stop/Go (Drop Test)

0-4

Hardness Stop/Go Solution (65ml)


Iron LR (Comparator)

Dt1129
0-1

FE5 (65ml)

Dt1110

Sulphuric Acid 50% (65ml)

Dt1155

Iron HR (Comparator)

0 - 10

FE10 (65ml) (also requires Sulphuric Acid 50%)


Molybdate VHR (Comparator)

Dt1247
0 - 500

Molybdate HR (65ml)

Dt1127

Nitrite (Drop Test)

0 2000

N1 (65ml)

Dt1072

N2 (65ml)

Dt1073

Phosphonate (Drop Test)

0 - 20

P1/4L (65ml)

Dt1514

P5 (65ml)

Dt1075

Calibration Solutions for EC1 & pH1 Meter


Standard Conductivity 1413S (65ml)

Dt1109

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

www.accepta.com

24

Section 4.2
Cooling (Open & Closed) Test Kit (Backpack) - Cool3002BP
Acceptas cooling (Open & Closed) Test Kit (Backpack Version)
is designed for use on Cooling Towers and many types of
Closed Water Systems such as Chilled Water Circuits and Heating systems.
The Backpack Test Kit has most of the reagents and
components that are normally contained in a standard Open &
Closed Test Kit but formatted into a backpack design for use by
the commuter in busy commercial areas.
It includes all the equipment and reagents necessary to perform
the below noted tests. Replacement reagents and components
are available which make this kit a lasting addition to any water
treatment professional. Simple to use and fully portable.
The Cooling (Open & Closed) Backpack Test Kit is presented in its own robust case and harness and
includes all the equipment and reagents necessary to effectively test and monitor system waters.
This test kit includes the following:

Contents

Code

Waterproof Back Pack Case with Foam Inserts

Eq5026E

Waterproof Instructions

Eq5084

1 x Plastic Comparator

Eq5085

2 x 10ml Comparator Cells

Eq5006

3 x Rigid Bottle 250ml Wide Neck

Eq5064

2 x 65ml Plastic Test Bottle

Eq5018

1 x Filter Holder 25mm

Eq5044

1 x Filter Papers GF/C (50pk)

Eq5048

1 x 10ml Luer Lock Syringe

Eq5073

1 x 20ml Luer Lock Syringe

Eq5075

1 x 5/10ml Tube

Eq5015

PH1 - pH/Temperature Meter

0 - 14

pH1

EC1 - Conductivity/TDS/Temperature Meter

0 - 20.00 mS

EC1

Alkalinity M (Drop Test)

5 - 2400

TA4 (65ml

Dt1004

PA2/TA2 (65ml)

Dt1005

TA3 (65ml)

Dt1006

Hardness, Total (Drop Test)

5 - 1200

TH2 (65ml)

Dt1046

H/TH4/CH3 (65ml)

Dt1049

TH3 (65ml)

Dt1044

TH5 (65ml)

Dt1047

www.accepta.com

25

Section 4.2
Cooling (Open & Closed) Test Kit (Backpack) - Cool3002BP

(continued)
Contents

Range:

Hardness, Calcium (Drop Test)

5 - 1200

Code

CH2 (65ml)

Dt1043

CH1P (20g) (also requires TH3 & H/TH4/CH3)

Dt1050

Hardness, Stop/Go (Drop Test)

0-4

Hardness Stop/Go Solution (65ml)

Dt1129

Chloride (Drop Test)

0-3000

BC1/CC1 (65ml)

Dt1023

BC2 (65ml)

Dt1026

CC2 (65ml)

Dt1024

Iron LR (Comparator)

0-1

FE5 (65ml) See below note*

Dt1110

Iron HR (Comparator)

0.5 -10

FE10 (65ml) See below note*

Dt1247

Bromine (Comparator)

0-5

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD Nitrite Powder (20g)

Dt1295

Molybdate VHR (Comparator)

0-500

Molybdate HR (65ml)

Dt1127

Nitrite (Drop Test)

0-2000

N1 (65ml)

Dt1072

N2 (65ml)

Dt1073

Phosphonate (Drop Test)

0-20

P1/4L (65ml)

Dt1514

P5 (65ml)

Dt1075

Calibration Solutions for EC1 & pH1 Meter


Standard Conductivity 1413S (65ml)

Dt1109

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

* For true Soluble and Total Iron determination, Sulphuric Acid 50% and 0.45 micron filter papers
are required and can be ordered separately.

www.accepta.com

26

Section 4.3
Closed Water Systems Test Kit - Clo3003/Clo3003F
Acceptas comprehensive Closed Water System test kit is based
on colour comparator and drop test chemistries and has been
developed specifically for engineers and water treatment
professionals involved with the maintenance and management
of closed systems to ensure optimum operating conditions.
Closed water systems require careful test monitoring to ensure
the correct water conditions are achieved during the course of a
treatment programme.
Failure to maintain the correct dosage levels can lead to scaling,
corrosion and increased biological activity which can lead to
potentially unstable water conditions.
This kit is presented in its own robust case and includes all the equipment and reagents necessary to
effectively test and monitor Closed Water System to ensure optimum operating conditions are
achieved and maintained.
This test kit includes the following:

Contents

Range

Code

2011 Medium Case with Foams

Eq5028/2

Waterproof instructions

Eq5084

1 x 20ml Standard Syringe

Eq5168

1 x Plastic Comparator

Eq5085

2 x 10ml Comparator Cells

Eq5006

1 x 5/10ml Tube

Eq5015

PH1 - pH/Temperature Meter

0 - 14

pH1

EC1 - Conductivity/TDS/Temperature Meter

0 - 20.00 mS

EC1

Iron HR (Comparator)

0.5 - 10

FE10 (65ml)

Dt1247

Molybdate VHR (Comparator)

0 - 500

Molybdate HR (65ml)

Dt1127

Nitrite (Drop Test)

0 - 2000

N1 (65ml)

Dt1072

N2 (65ml)

Dt1073

Calibration Solutions for EC1 & pH1 Meter


Conductivity Standard 1413s (65ml)

Dt1109

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

Please Note: CLK003F includes Filtration & Sulphuric Acid 50% for True Soluble and Total Iron.
Liquid equivalent reagents are available on request.

www.accepta.com

27

Section 4.4
Chlorination Test Kit - Chlor3004
Acceptas chlorination test kit is based on colour comparator
chemistry and has been developed specifically for engineers
and water treatment professionals involved with the chlorination
and
disinfection of water systems.
Water system chlorinations require careful test monitoring to
ensure the correct water conditions are achieved during the
course of the disinfection procedure. Failure to achieve the
correct dosage levels can lead to unsuccessful disinfections,
whilst elevated levels can lead to potentially corrosive water
conditions.
This kit is presented in its own robust case and includes all the
equipment and reagents necessary to effectively test and monitor the chlorination procedure.
This kit includes all the reagents and equipment required to allow the monitoring of low range
chlorine (0 to 4ppm) and high range chlorine (0 to 300ppm). These are required to ensure the correct
system conditions are achieved.
This test kit includes the following:

Contents

Range

Code

2004 Mini Case with Foams

Eq5030

Waterproof instructions

Eq5084

1 x Plastic Comparator

Eq5085

2 x 10ml Comparator Cells

Eq5006

1 x Tablet Crusher

Eq5079

PH1 - pH/Temperature Meter

0 - 14

Chlorine LR (Comparator)

0-4

pH1

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD No3 Solution C (30ml)

Dt1507

Chlorine HR (Comparator)

10 - 300

Chlorine HR (65ml)

Dt1179

Acidifying Solution (65ml)

Dt1180

Calibration Solutions pH1 Meter


pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

www.accepta.com

28

Section 4.5
Boiler Water Test Kit - Blr3001
Acceptas comprehensive Boiler Water Test Kit is based on a
colour comparator and drop test chemistries and has been developed specifically for engineers and water treatment professionals who are involved with the maintenance and management of boilers and boiler systems.
Boiler Water and feed-water systems require careful test
monitoring to ensure the correct water conditions are maintained
at all times. Failure to maintain the correct water treatment
programs can lead to serious problems including reduced boiler
efficiency, scale, corrosive water conditions and reduced steam
purity.

This professional Boiler Water Test kit is presented in its own robust case and includes all the
equipment and reagents necessary to effectively test and monitor system waters to ensure optimum
operating conditions are achieved and maintained.
This test kit includes the following:

Contents

Range

Code

2019 Maxi Case with Foams

Eq5027

Waterproof Instructions

Eq5084

1 x 20ml Luer Lock Syringe

Eq5075

1 x 10ml Luer Lock Syringe

Eq5073

1 x Filter Holder 25mm

Eq5044

1 x Filter Papers GF/C (50pk)

Eq5048

2 x 65ml Plastic Test Bottle

Eq5018

1 x 5/10ml Tube

Eq5015

1 x Plastic Comparator

Eq5085

2 x 10ml Plastic Comparator Cells

Eq5006

PH1 - pH/Temperature Meter

0 - 14

pH1

EC1 - Conductivity/TDS/Temperature Meter

0 - 20.00 mS

EC1

Alkalinity P (Drop Test)

5 - 2400

PA1 (65ml)

Dt1001

PA2/TA2 (65ml)

Dt1005

TA3 (65ml)

Dt1006

Alkalinity M (Drop Test)

5 - 2400

TA4 (65ml) (also uses PA2/TA2 & TA3)


Alkalinity OH (Drop Test)

Dt1004
5 - 2400

PA3 (65ml) (also uses PA1, PA2/TA2 & TA3)


Chloride (Drop Test)

Dt1007
0 - 3000

BC1/CC1 (65ml)

Dt1023

BC2 (65ml)

Dt1026

CC2 (65ml)

Dt1024

www.accepta.com

29

Section 4.5
Boiler Water Test Kit - Blr3001 (continued)
Contents

Range

Hardness, Stop/Go (Drop Test)

0-4

Hardness Stop/Go Solution (65ml)


Hardness, Total LR (Drop Test)

Code
Dt1129

5 - 120

TH2 (65ml)

Dt1046

TH5 (65ml)

Dt1047

TH3 (65ml)

Dt1043

Phosphate (Comparator)

0 - 80

PB1 (65ml)

Dt1111

PB2 (65ml)

Dt1112

Sulphite (Drop Test)

5 - 300

S1 (40g)

Dt1092

S2 (65ml)

Dt1093

Calibration Solutions for EC1 & pH1 Meter


Standard conductivity 1413S (65ml)

Dt1109

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

20% Acetic Acid (65ml)

Dt1103

Liquid equivalent reagents are available on request.

www.accepta.com

30

Section 4.6
Legionella Compliance Test Kit - Leg3006
Acceptas Legionella compliance kit is based on colour comparator and drop test chemistries and has been developed specifically for engineers and water treatment professionals involved in
the weekly and monthly analysis of water systems.
Cooling Water systems require careful test monitoring to ensure
the correct water conditions are achieved to reduce the risk of
Legionella. Failure to keep the system under control can lead to
scale, corrosion and the growth of the potentially fatal Legionella
bacteria.
This kit is presented in its own robust case and includes all the
equipment and reagents necessary to effectively monitor the
water conditions.
Replacement reagents and other components are available, please refer to the relevant section.
This test kit includes the following:

Contents

Range

Code

2019 Maxi Case with Foams

Eq5027

Waterproof Instructions

Eq5084

1 x 20ml Standard Syringe

Eq5168

1 x 10ml Standard Syringe

Eq5177

2 x 65ml Plastic Test Bottle

Eq5018

1 x 5/10ml Tube

Eq5015

1 x Plastic Comparator

Eq5085

2 x 10ml Plastic Comparator Cells

Eq5006

PH1 - pH/Temperature Meter

0 - 14

pH1

EC1 - Conductivity/TDS/Temperature Meter

0 - 20.00 mS

EC1

Alkalinity M (Drop Test)

5 - 2400

TA4 (65ml)

Dt1004

PA2/TA2 (65ml)

Dt1005

TA3 (65ml)

Dt1006

Bromine (Comparator)

0-5

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD Nitrite Tablets (50pk)

Dt1131

Chloride (Drop Test)

0 - 3000

BC1/CC1 (65ml)

Dt1023

BC2 (65ml)

Dt1026

CC2 (65ml)

Dt1024

www.accepta.com

31

Section 4.6
Legionella Compliance Test Kit - Leg3006 (continued)
Contents

Range

Hardness, Total (Drop Test)

5 - 1200

Code

TH2 (65ml)

Dt1046

TH5 (65ml)

Dt1047

TH3 (65ml)

Dt1044

H/TH4/CH3 (65ml)

Dt1049

Hardness, Calcium (Drop Test)

5 - 1200

CH2 (65ml)

Dt1043

CH1P (20g) (also requires TH3 & H/TH4/CH3)

Dt1050

Hardness, Stop/Go (Drop Test)

0-4

Hardness Stop/Go Solution (65ml)


Iron LR (Comparator)

Dt1129
0-1

FE5 (65ml)

Dt1110

Calibration Solutions for EC1 & pH1 Meter


Standard Conductivity 1413S (65ml)

Dt1109

pH 4 (65ml)

Dt1119

pH 7 (65ml)

Dt1118

pH 10 (65ml)

Dt1161

www.accepta.com

32

Section 4.7
Resin Test Kit - Res3008
Ion exchange Resins should be checked when the plant is
serviced to determine if the ion exchange resin is suffering
from fouling or damage which will reduce the plant efficiency.
Acceptas portable and easy to use kit allows the qualitative
analysis of ion exchange resins for the three main problems
encountered when water softeners or ion exchange plant
efficiency is reduced.
The ion exchange resin can be checked for Iron fouling,
organic fouling and resin bead optical assessment. Failure to
maintain good quality resins will lead to serious problems
including reduced efficiency and the build-up of scale and
increased microbiological activity, which may include the
growth of Legionella bacteria.
The Resin Test kit is presented in its own robust case and includes all the equipment and reagents
necessary to effectively test and monitor the qualitative condition of ion exchange resins.
This test kit includes the following:

Contents

Range

Code

2004 Mini Case with Foam

Eq5030

Waterproof Instructions

Eq5084

1 x Optic Magnifier

Eq5034

1 x 65ml Plastic Test Bottle

Eq5018

1 x White Spoon, 0.5ml

Eq5382

1 x RA1 Iron Test Reagent (65ml)

Dt1338

1 x RA2 Iron test Reagent (65ml)

Dt1336

1 x RA3 Organic Test Reagent (65ml)

Dt1339

1 x De-ionised Water (65ml)

Dt1210

www.accepta.com

33

Section 4.8
Manual Silt Density Kit SDI001
Depleting supplies of fresh water, ground water contamination
and the rising cost of water have compelled industries to
increasingly turn to the desalination of brackish/sea water as
well as water recovered from treated industrial effluent and
secondary treated municipal sewage.
All these recycled water systems use reverse osmosis (RO)
system for removal of dissolved solids. The presence of finely
divided particles in feed water to an RO system can cause
serious problems as they are too small to be retained by
conventional pre-treatment systems and they find their way to
the RO membrane.
The function of an RO membrane is to concentrate dissolved
solids on one side of the membrane and allow water molecules
to permeate through the other side. Suspended, colloidal
particles are larger than dissolved solids and are rejected by the
membrane.
These fine un-dissolved suspended particles tend to settle on the surface and in the process, foul the
membrane. The net result is an increase in feed pressure, reduced flow and high conductivity of
permeate. Spiral wound and hollow fine fibre membranes are the most vulnerable and once fouled,
cleaning of the element is often difficult.
Use of the Kit
Silt Density Index (SDI) is an empirical test developed for measuring the rate of fouling of nano
filtration (NF) or RO membranes.
Suspended solids and colloidal materials in feed water are one of the biggest problems in reverse
osmosis systems. Although most systems have some pre-treatment, including 5-micron pre-filters,
these fine particles are responsible for the fouling of reverse osmosis membranes.
In order to measure the degree of this fouling problem, a concept called Silt Density Index is used.
Here, filtration rates are calculated by exposing a 0.45-micron filter to the feed water under pressure.
An SDI of less than 5 is typically considered acceptable for reverse osmosis systems. This means
membranes should foul at a very low rate at SDI values of less than 5. Although this concept works
most of the time, there are exceptions when a lower SDI (less than 3) is desirable due to the nature
of the suspended solids in feed water.

Contents

Range

Code

Waterproof Instructions

Eq5084

47mm Filter Holder

Eq5086

0.45m Micron Filter Papers (47mm) (50pk)

Eq5181

500ml Measuring Cylinder

Eq5183

Stopwatch/Clock

Eq5239

Dull Blunt Tweezers

Dt1240

SDI Assembly

Dt1182

www.accepta.com

34

Section 5.0
Pocket Test Meters

www.accepta.com

35

Section 5.1
PH1 - pH/Temperature Meter
Acceptas waterproof pH1 Meter has a built in smart chip which offers many
advanced functions and features for a stick style pH Meter.
Features:

Waterproof and rugged enough to withstand harsh environments.

LCD display.

Displays Max & Min values with data hold.

Easy to replace pH electrode.

Exchangeable with an ORP Probe for Redox.

Auto recognition of buffer solutions.

Automatic temperature compensation.

Simultaneous display of pH and temperature.

Auto shut off after 10 minutes.

Icons on display for easy recognition of function.

Unique flat electrode which is very robust and is


almost unbreakable.

Specifications:
pH:
Temperature:
Resolution:
Accuracy:
Power:
Dimensions:
Weight:

0.00 to 14.00pH
0 to 90C
0.01 pH
0.01pH, 1.8F/1C
2 x CR2032 Button Batteries
195 x 40 x 36mm
150g

Optional Extra:
Redox Probe

Code:
RE1P

Replacement Probe:
pH Probe

Code:
pH1P

www.accepta.com

36

Section 5.2
EC1 - Conductivity/TDS/Temperature/Salinity Meter
Acceptas waterproof EC1 Meter has a built in smart chip which offers many
advanced functions and features for a stick style EC Meter.
Features

Unit is waterproof and rugged enough to withstand many harsh


environments.

LCD Display.

Displays Max & Min values with data hold.

Easy to replace conductivity electrode.

Auto recognition of conductivity solutions.

Automatic temperature compensation.

Simultaneous display of conductivity and temperature.

Auto shut off after 10 minutes.

Icons on display for easy recognition of function.

Specifications

Ranges

Max Resolution

Basic Accuracy

Conductivity:

0.1S/cm
1S/cm
0.01mS/cm
0.1ppm (mg/L)
1ppm (mg/L)
0.01ppt (g/L)

2% FS

Temperature:
Power:

0 to 199.9S/cm
200 to 1999S/cm
2.00 to 19.99mS/cm
0 to 99.9ppm (mg/L)
100 to 999ppm (mg/L)
1.00 to 9.99ppt (g/L)
0 to 1000ppm
100 to 999ppm (mg/L)
1.00 to 12.00ppt
0 to 90F
2 x CR2032 Batteries

Dimensions:

36 x 173 x 41mm

Weight:

110g

Replacement Probe:
EC/TDS Probe

EC1P

TDS:

Salinity

2% FS

1ppm / 0.01ppt
1ppm (mg/L)
0.1C

www.accepta.com

0.2C

37

Section 5.3
PH100 - Extech pH/Temperature Meter
The waterproof ExStik pH100 Meter has a built in smart chip which offers
advanced functions and features to a stick style pH Meter not found anywhere
else and has a robust flat surface electrode.
Features:

Flat surface pH electrode, rugged for harsh environments.

Internal memory stores up to 15 labelled readings for easy recall.

CAL feature, tells you when to recalibrate your meter.

Analogue bar graph to conveniently view trends.

Renew indicator tells you its time to replace your electrode.

1, 2 or 3 point calibration automatically recognises buffer solutions.

Automatic temperature compensation & waterproof to IP 57.

Simultaneous display of pH and temperature & indicates reading stability.

Data Hold, Auto Power Off and Low Battery Indication.

Waterproof design floats in water.

Interchangeable probes available for Chlorine & ORP

Optional weighted base (EX006) holds plastic cup and ExStik Meter.

Complete with flat surface pH electrode, protective sensor cap, sample


cup with four 3V CR-2032 button batteries, and 1.2m neck strap.

Specifications:
pH:
Temperature:
Resolution:
Accuracy:
Power:
Dimensions:
Weight:

0.00 to 14.00pH
23 to 194F (-5 to 90C)
0.01pH, 0.1
0.01pH, 1.8F/1C
4 x CR2032 Button Batteries
35.6 x 172.7 x 40.6mm
110g

Optional Extra:

Code:

Weighted Base and 5 Solution Cups

EX006

Replacement Probe:
Probe (PH105)

Code:
Eq5039

www.accepta.com

38

Section 5.4
EC400 - Extech Conductivity/TDS/Temp/Salinity Meter
The waterproof ExStik Conductivity/TDS/Salinity Meter offers one high accuracy
multi-range sensor which measures four parameters (Conductivity, TDS, Salinity
and Temperature).
Features

Auto ranging meter offers 3 ranges to measure, pure water, salinity solution, waste, boiler and cooling water using the same conductivity cell.

6 units of measure: S/cm, mS/cm, ppm, ppt, mg/L and g/L.

Internal memory stores up to 15 labelled readings for easy recall.

Waterproof design to withstand wet environments meets IP57 Standard.

Adjustable Conductivity to TDS ratio factor from 0.4 to 10 conveniently


calculates the TDS value with easy to replace conductivity cell module.

Large digit, digital display with analog bar graph to indicate sample trends.

Self calibration on power up, data hold, Auto Power Off & low battery
Indication.

Automatic Temperature Compensation of 2% per C.

Simultaneous display of Conductivity, TDS, or Salinity and temperature.

EC400 includes meter and Conductivity cell, protective sensor cap,


sample cup with cap, batteries and 1.2m neck strap.

Specifications

Ranges

Max Resolution

Basic Accuracy

Conductivity:

0.1S/cm
1S/cm
0.01mS/cm
0.1ppm (mg/L)
1ppm (mg/L)
0.01ppt (g/L)
0.1ppm (mg/L)
1ppm (mg/L)
0.01ppt (g/L)
0.1F/C

2% FS

Temperature:
Power:

0 to 199.9S/cm
200 to 1999S/cm
2.00 to 19.99mS/cm
0 to 99.9ppm (mg/L)
100 to 999ppm (mg/L)
1.00 to 9.99ppt (g/L)
0 to 99.9ppm (mg/L)
100 to 999ppm (mg/L)
1.00 to 9.99ppt (g/L)
32 to 149F (0 to 65C)
4 x CR44W Batteries

Dimensions:

36 x 173 x 41mm

Weight:

110g

Optional Extras:
Weighted Base and 5
Solution Caps

Code:
EX006

Replacement Probe:
EC405 Probe

Code:
Eq5032

TDS:

Salinity:

www.accepta.com

2% FS

2% FS

1.8F/1C

39

Section 5.5
EC500 - Extech Combined pH/Conductivity/TDS/
Temperature Meter
The waterproof ExStik II pH/Conductivity Meter Combination comes with a
rugged flat surface pH electrode and an Auto-ranging high accuracy conductivity
cell.
Features

Measures 5 parameters including Conductivity, TDS, Salinity, pH, and


Temperature using one electrode.

9 units of measure: pH, S/cm, mS/cm, ppm, ppt, mg/L, g/L, C, F

Analog bargraph indicates trends.

Memory stores up to 25 labelled readings

Adjustable Conductivity to TDS ratio from 0.4 to 1.0; 0.5 fixed Salinity ratio.

RENEW feature alerts user when electrode needs replacement.

Auto Power Off and Low Battery Indicator & waterproof to IP57.

EC500 meter includes electrode, protective sensor cap, sample cup with
cap, four 3V CR-2032 button batteries and 1.2m neck strap.

EC510 Kit includes EC500, 84S/cm, 1413S/cm and 12.88mS/cm


calibration standards, pH buffer pouches (1 each of 4, 7,10 pH plus rinse
solution), weighted base, 3 sample cups with caps and case.

Specification

Range

Max Resolution

Basic Accuracy

Conductivity:

0.1S/cm

2% FS

0.1ppm (mg/L)

2% FS

pH:

0 to 199S/cm
200 to 1999S/cm
2.00 to 19.99mS/cm
0 to 99.9ppm (mg/L)
100 to 999ppm (mg/L)
1.00 to 9.99ppt
0.00 to 14.00pH

0.01pH

0.01pH

Temperature:
Waterproof:
Memory:
Dimensions:
Weight:

32 to 149F (0 to 65C) 0.1F/C


iP67
25 datasets
36 x 186 x 41mm
110g

Optional Extras:
Weighted Base and 5
Solution Cups

Code: EX006

Replacement Probe:
Probe (EC505)

Code: Eq5041

TDS/Salinity:

www.accepta.com

1.8F/1C

40

Section 5.6
CL200 - Extech Total Chlorine/Temperature Meter
The waterproof ExStik CL200 Chlorine Meter gives a direct reading of Total
Chlorine down to 0.01ppm and is unaffected by colour/turbidity of the sample.
Features

Direct reading of Total Chlorine provides fast and easy measurements (less
than 2 minutes).

Low detection limit down to 0.01ppm.

Wide dynamic range of measurement up to 10ppm (use dilution method for


10 to 50ppm).

Unaffected by sample colour or turbidity.

Automatic electronic calibration.

Memory stores, tags and recalls up to 15 readings.

Unique flat surface chlorine electrode.

Waterproof to IP67 standard.

The state of the art LCD simultaneously displays ppm of Total


Chlorine and Temperature plus analog bargraph indicator.

Complete with meter and flat surface Chlorine electrode, ExTab reagent
tablets (50 tests), protective sensor cap, sample cup with cap, four 3V
CR-2032 Button Batteries, and a 1.2m neck strap.

Specifications
Range in ppm:
Temperature:
Resolution:
Accuracy:
Power:
Dimensions:
Weight:

0.01 to 10.00ppm (10 to 50ppm using dilution method)


23 to 194F (-5 to 90C)
0.01ppm ; 0.1F/C
10% of reading 0.01ppm; 1.8F/1C
4 x CR-2032 Button Batteries
35.6 x 172.7 x 40.6mm
110g

Optional Extras
Weighted Base and 5 Solution Cups:
Replacement Probe (CL205)

Code: EX006
Code: Eq5040

www.accepta.com

41

Section 5.7
DO600 - Extech Dissolved Oxygen/Temperature Meter
The waterproof ExStik II Dissolved Oxygen Meter incorporates an easy to
replace screw on membrane cap with optional extension cables.
Features

Oxygen level displayed as % Saturation from 0 to 200.0% or


Concentration from 0 to 17.00ppm (mg/L).

Adjustable Altitude Compensation (0-20,000ft in 1,000ft increments).

Adjustable Salinity Compensation from 0 to 50ppt.

Analog bargraph indicates trends.

Memory stores up to 25 data sets with DO and Temperature reading.

Self calibration on power up.

Data Hold, Auto Power Off, Low Battery Indicator.

Waterproof to IP57.

Optional 1m or 5m extension cable with probe weight.

Complete with DO electrode, protective sensor cap, spare membrane cap,


electrolyte, four 3V CR-2032 Button Batteries and 1.2m neck strap.

Specification

Range

Max Resolution

Basic Accuracy

DO (saturation mode):
DO (concentration mode):
Temperature:

0 to 200.0%
0 to 20.00ppm (mg/L)
32 to 122F (0 to 50C)

0.1%
0.01ppm (mg/L)
0.1F/C

2% FS
0.4ppm (mg/L)
1.8F (1C)

Dimensions
Weight:
Power:

36 x 176 x 41mm
110g
4 x CR2032 Button Batteries

Optional Extras
Weighted Base and 5 Solution Cups:

Code: EX006

Replacement Probe:

Code: D0605

www.accepta.com

42

Section 5.8
RE300 - Extech ORP Meter
The Extech ORP Meter has flat surface electrodes which provides On-the-Spot
measurements and also has a large display with bar-graph.
Features:

ORP from 999 to 999mV, resolution of 1mV and 4mV accuracy.

Automatic electronic self calibration.

Simulated analogue bar graph displays change in ORP reading.

Memory stores and recalls 15 readings and saves last calibrated value.

Data validation indicators show user the reading is stabilised.

Large 3-1/2 digit (2000 count) digital display with bar graph.

Data Hold, Auto Shut-off and Low Battery Indicator.

Easy to replace electrode module is interchangeable with pH and Chlorine


modules; (built in chip automatically recognises the type of probe plugged
in for specific measurements).

Waterproof IP57 floats in water & protects the meter in wet environments.

Complete with meter and electrode, protective sensor cap, sample cup with
cap, four 3V CR-2032 Button Batteries and neck strap

Specifications
ORP (mV):
Resolution:
Accuracy:
Power:
Dimensions:
Weight:

999 to 999mV
1mV
4mV
4 x CR2032 Button Batteries
35.6 x 172.7 x 40.6mm
110g

Optional Extras
Weighted Base and 5 Solution Cups:

Code: EX006

Replacement Probe: (RE305)

Code: Eq5031

www.accepta.com

43

Section 5.9
Refractometer - Glycol Tester (RefG300)
Acceptas refractometer is a precision optical instrument designed
to measure the concentration of Glycol as PEG or MEG displayed
as a % and freeze point
It is easy to use, you simply place a few drops of the treated solution with the pipette included on to the prism glass and hold up to
the light. You can then read the concentration of Glycol in % or
freeze point on to the lens.
Our Refractometer has
compensation system.

built-in

automatic

temperature

Measuring Range
Ethylene Glycol: 60C - 0C with a resolution of 5C
Polypropylene: 50C - 0C with a resolution of 5C
Battery Acid: 1.100-1.400sg with a resolution of 0.01sg

Other Refractometers for Coolants, Brix, Sugars etc. are available on request.
Please contact us for details.

www.accepta.com

44

Section 6.0
Professional Test Meters

www.accepta.com

45

Section 6.1
Martini MI806 - 4 in 1 pH/Conductivity/TDS/Temp
The Martini Mi806 is a multi-function portable meter measuring
pH, Conductivity, TDS and temperature using a single probe.

Measures 4 parameters with 1 single probe.

You can select from a range of calibration buffers and


also the temperature scale (C or F).

The multi-parameter probe Mi806P includes pH/EC/TDS


and temperature sensors all in one rugged unit.

TDS factors from 0.45 to 1.00, range of temperature


coefficients () from 0.0 to 2.4% for greater reproducibility.

Stability Indicator prompts when the reading stabilizes.


Auto-Hold Function freezes reading for later viewing.

Large and Easy-to-Read display provides simultaneous


readings of pH and Temperature or EC/TDS and
temperature

Specifications
Range:

pH
EC
TDS
Temp
Resolution: pH
EC
TDS
Temp
Accuracy (25C): pH
EC/TDS
Temp
Typical EMC Deviation: pH
EC/TDS
Temp
Typical Compensation:
pH Calibration:
EC Calibration:
EC/TDS Conversion Factor:
Probe (Included):

0.00 to 14.00 pH
0.00 to 20.00 mS/cm
0.00 to 10.00 ppt
0.0 to 60.0C / 32.0 to 140.0F
0.01pH
0.1 mS/cm
0.01 ppt
0.1C / 0.1F
0.01 pH
2% FS
0.5C / 1F
0.02 pH
2% FS
0.5C / 1F
Automatic from 0 to 60C;
6 adj. from 0.0 to 2.4%/C
1 or 2-point with automatic buffer recognition
Automatic, 1 point
Adj. from 0.45 to 1.00
Mi806P (MA851D/1) amplified pH/EC/TDS/Temperature
probe with DIN connector and 1m cable

Environment:
Battery Type (Included):
Battery Life:
Auto-off:
Dimensions:
Weight (with battery)

0 to 50C / 32 to 122F; 100% RH max


1 x 9Valkaline
Approx. 300 hours
After 8 minutes
200 x 85 x 50mm
260g

Replacment Probe:
MI806 Probe

Code: MI806P

www.accepta.com

46

Section 6.2
Eutech pH11 - pH/Temperature Meter
The Eutech pH11 is a simple to use, accurate, reliable
hand held meter which has been designed to handle the
tough environment of field work.

Large, Easy to Read display with simultaneous


readings with user-friendly icons.

5-point Push-Button Calibration with Auto-Buffer


recognition for quick calibration with no mistakes.

Automatic temperature compensation.

Stores/Recalls up to 100 Data sets with temperature


readings.

Supplied with probe & batteries.

Stability indicator prompts stable reading.

Supplied with pH buffers solution 4.0 & 7.0

Self-Diagnostic with message codes


troubleshooting.

for

Specifications

Ranges

Max Resolution

Basic Accuracy

pH:
mV:

-2 to 16.00
0 to 1000 mV

0.01pH
0.01pH

0.02 pH
2mV

Temperature:

-5 to 105C

0.1C

0.5C

Power:

4 x AAA Batteries

Dimensions:

85 x 185 x 40 mm

Weight:

224g

www.accepta.com

easy

47

Section 6.3
Eutech CON 11 - Conductivity Meter
The Eutech CON 11 is a simple to use, accurate, reliable
hand held meter which has been designed to handle the
tough environment of field work.

Large, Easy-to-Read LCD Display with simultaneous


readings and user-friendly icons.

Stability indicator prompts when reading stabilizes.

Auto - ranging Conductivity to detent the appropriate


measurement range - ensures the best resolution.

User Customisable Functions for options:


Normalisation Temperature. Temperature coefficient,
TDS factor & cell constant.

Automatic temperature compensation.

Supplied with calibration solution.

Auto-off feature after 5 minutes to save battery life.

Single & Multi-point Automatic or Manual Calibration.

Specifications

Ranges

Max Resolution

Basic Accuracy

Conductivity:

0 to 19.99 S/cm
20.0 to 199.9 mS/cm
2.00 to 19.99 mS/cm
20.0 to 199.9 mS/cm

0.1S/cm
0.01mS/cm

1%

0.1C

1.8F/1C

Temperature:

-9 to 120C

Power:

4 x AAA Batteries

Dimensions:

85 x 185 x 40 mm

Weight:

224g

www.accepta.com

48

Section 6.4
Eutech PC300 - Combined pH/Condy/TDS/Temp Meter
The Eutech PC 300 is designed to readily withstand the
rigours of portable analysis, while reliably measuring pH,
Conductivity and Temperature in a simple professional
manner.

Waterproof and Dust proof Housing - IP67 rated.

Multi-parameter- toggle between pH/temperature and


Conductivity/temperature at touch of buttons.

Multi-point Push-button Calibration (up to 3/4 points for


pH/Conductivity) - for easy, quick calibration.

Auto-Ranging for Conductivity measurements, fast


response and best resolution over range.

User-Customization for enhanced flexibility, viewing of


Conductivity/TDS cell constants per range, electrode
diagnosis, pH slope/offset/mV base value.

Stability indicator prompts reading stability.

Auto-Hold Function automatically freezes reading


when stabilized for easy viewing and recording.

Auto-Power Off saves battery power after non-use.

Self-Diagnostic message codes for troubleshooting.

Large Easy-to-Read Custom LCD with simultaneous


display for optimum viewing with user-friendly icons

Specifications

Ranges

Max Resolution

Basic Accuracy

pH:

-2 to 16.00

0.01pH

0.02 pH

mV:

0 to 1000 mV

1 Mv

2mV

Temperature:

-5 to 105C

0.1C

0.5C

Power:

4 x AAA Batteries

Dimensions:

85 x 185 x 40 mm

Weight:

224g

www.accepta.com

49

Section 6.5
Jenway 350 - pH Meter
The Jenway 350 pH Meter offers simple yet professional
performance for the operator who requires reliable results
from trusted technology. With its single pH input and
manual temperature compensation the 350 is easy to use,
but also offers such advanced features as the 32 reading
non-volatile memory.
Features

Power on self-check routine with 32 reading


data storage.

Environmentally protected case to IP65.

Automatic or Manual calibration with 500


hours battery life.

Simultaneous pH and temperature reading.

Full range of application specific electrodes


and consumables.

The custom back-lit liquid crystal display simultaneously shows the pH reading and the manually set
temperature compensation value that is simply adjusted with the up and down arrow keys. A one or
two point calibration can be selected and, for ease of operation, automatic buffer recognition can be
used. In special applications this can be overridden, enabling calibration to be set at any two points
across the full pH range.
An indication of battery life is also permanently shown on the display. An automatic switch off facility
helps to conserve battery life. This product is ideal for use in field or any portable situation.
Specifications
pH Range:
Resolution (Accuracy):
Manual Temperature Compensation:
Resolution:
Auto Buffer Recognition:
Calibration:
Power:
Battery Life:
Size:
Weight:

-2.00 to 16.00pH
0.01pH ( 0.02pH)
0 to 100C / 32 to 212F
0.1C / 1F
4.00, 7.00, 9.22 & 10.00 (manual override)
User selectable 1 or 2 point
2 x AA batteries
500 hours typical (@25C with alkaline cells)
175 x 75 x 35 mm
250g

www.accepta.com

50

Section 6.6
Jenway 470 - Conductivity/TDS/Temp Meter
The Jenway 470 Conductivity/TDS/Temp Meter is a general
purpose hand held meter offering a wide measuring range, which
is further complimented by the auto-ranging function that ensures
results are displayed with the highest resolution that can be
achieved.
Features

Automatic range selection for optimum resolution.

Automatic or manual calibration.

32 reading data storage.

Conductivity and TDS modes.

Power on self-test routine.

Calibration can be carried out automatically against standard solutions at 10S, 84S, 1413S and
12.88mS or a manual calibration can be made against any other standard value.
Standard conductivity measurements can be made quickly and easily using the default settings but
for more complex applications a full range of adjustments can be made. The reference temperature
can be set to 18, 20 or 25C and the temperature coefficient set from 0 to 4%/C. When using the
alternative TDS range the E/C ratio can be set from 0.5 to 0.8 to ensure conformance with all
operating procedures.
A simple dual function memory bar enables up to 32 readings to be stored and recalled from the nonvolatile internal memory.
An indication of battery life is also permanently shown on the display. An automatic switch off facility
helps to conserve battery life. This product is ideal for field or any portable situation.
Specifications:
Conductivity:
Ranges:
Resolution (Accuracy):
TDS Ranges:
Resolution (Accuracy):
Temperature Range:
Resolution Accuracy:
ATC & Manual ranges:
Cell constant:
Reference Temperature:
Temperature Coefficient:
Auto Standard Recognition:
Probe input:
Power:
Battery Life:
Size:
Weight:

6 switched ranges
0 to 19.99S - 0 to 1999mS*
0.1S to 1mS* (0.5% 2 digits)
6 switched ranges
0 to 19.99mg/l - 0 to 1999g/l*
0.01mg/l to 1g/l* (0.5% 2 digits)
-10 to 105C / 14 to 221F
0.1C/1F (0.5C/1F)
0 to 100C / 32 to 212F
Digitally settable 0.01 to 19.99
18, 20 or 25C settable
0.00 to 4.00%/C linear
10S, 84S, 1413S or 12.88mS (manual override)
Mini-DIN conductivity/temperature
2 x AA batteries
500 hours typical (@25C with alkaline cells)
175 x 75 x 35 mm
250g
* only with cell constant > 5

www.accepta.com

51

Section 6.7
Jenway 430 - Combined pH/Conductivity/TDS/Temp Meter
The 430 is designed to readily withstand the rigours of portable analysis, while reliably measuring pH and Conductivity in a simple and
professional manner.
Features

Simultaneous readout of pH, Conductivity or TDS and


temperature
Fully featured pH and Conductivity meters in a single,
hand held unit
Automatic or manual calibration of both functions
Power on self-check routine
Calibration diagnostics
Environmentally protected case to IP65

This product allows the simultaneous readout of pH, Conductivity or TDS and Temperature using the
custom backlit liquid crystal display. Calibrations are clearly indicated, together with the parameter in
error.
It offers 1 or 2 point pH calibration and automatic buffer recognition with manual override.
Conductivity calibration can be performed on standard solutions or by direct cell constant entry. The
conductivity/TDS range is automatically selected for optimum resolution and temperature
compensated using an adjustable temperature coefficient.
The 430 is supplied with a combined conductivity and pH probe assembly (a temperature sensor is
also incorporated to provide automatic temperature compensation). The probe connects to the
instrument via a single mini-DIN connector for operator convenience.
An indication of battery life is also permanently shown on the display. An automatic switch off facility
helps to conserve battery life. This product is ideal for field or any portable situation.
Specifications:
pH Range (1 or 2 point call):
Resolution:
Accuracy:
Conductivity Ranges:
Resolution:
Accuracy:
TDS Ranges:
Resolution:
Accuracy:
Temperature Ranges:
Resolution:
Accuracy:
ATC Range:
Manual Temp. Comp.:
Auto Buffer Recognition:
Auto Standard Recognition:
Cell Constant:
EC Ration (TDS):
Reference Temperature:
Temperature Coefficient:
Power:
Battery Life:
Size:
Weight:

0 to 14pH
0.01pH
0.02pH
5 switched ranges: 0 to 19.99S - 0 to 199.9mS
0.01S, 0.S, 1S, 0.01mS, 0.1mS
0.5% 2 digits
5 switched ranges: 0 to 19.99mg/l - 0 to 199.9g/l
0.01mg/l, 0.1mg/l, 1mg/l, 0.01g/l, 0.1g/l
0.5% 2 digits
-9.9 to +99.9C / 32 to 212F
0.1C/ 1F
0.5C / 1F
0 to 99.9C / 32 to 212F
0 to 99.9C / 32 to 212F
4, 7, 9.22 and 10.00 (manual override facility)
10S, 84S, 1413S & 12.88mS
0.01 to 19.99
0.50 to 0.80
18, 20 or 25C
0.00 to 4%/C
2 x AA batteries
100 hours typical (@25C with alkaline cells)
175 x 75 x 35 mm
250g

www.accepta.com

52

Section 6.8
TRANSEC - Conductivity/TDS/Salinity/Temp Meter
The Conductivity/TDS Meter HC3010 is a highly sophisticated meter with
ability to automatically display and convert in Siemen (S), mSiemen (Ms),
TDS in ppm and Salinity in ppt.
The meter is versatile and able to preset at different conversion factors.
User can select to display in Conductivity or TDS. Its 99 data memory
coupled with real time clock enable you to record reading with date and
time.
For QC control, data can be analysed to display maximum and minimum
readings over all saved data. The meter comes complete in a hard case
with a set of calibration fluids for on the spot calibration.
Auto-range measurement
Multi range display of conductivity and TDS
Dual conductivity or TDS and temperature reading display
Save up to 99 data in memory with real time clock
Able to show maximum and minimum reading over saved data
Stability indicator prompts whenever reading stabilizes
Automatic temperature compensation (ATC)
Supplied with probe & batteries
Auto-off feature to save battery life.

Specifications

Ranges

Max Resolution

Conductivity:

0 to 1999 S/cm
20 to 199.9 mS/cm
2.00 to 19.99 ms/cm
20.0 to 199.9 ms/cm

0.1S/cm
0.01mS/cm

Temperature:

-5 to 105C

0.1C

Power:

4 x AAA Batteries

Dimensions:

40 x 195 x 36 mm

Weight:

150g

www.accepta.com

Basic Accuracy

1.8F/1C

53

Section 6.9
TRANSPH - pH (also ORP Meter with additional probe)
The pH Meter HP3040 is a portable yet highly accurate pH meter.
Used in all industries, the meter uses the regular BNC connector and accepts a variety of electrodes for special measurement needs.
The meter comes complete in a hard case with calibration buffer solutions
and offers ATC (automatic temperature compensation).
Large LCD with multiple display, displays pH, temperature and time
simultaneously
Multi point calibration - Automatic buffer recognition with built in
standards pH 4, 7 & 10
Custom set available - Manual set to any buffer standard
Up to 5 point calibrations
Capable of reading mV readings with additional probe
Stores/recalls up to 99 data sets with date & time
Supplied with probe & batteries
Stability indicator prompts whenever reading stabilises
Self- Diagnostic with message codes for easy troubleshooting
Auto-off feature to save battery life

Specifications Ranges

Max Resolution

Basic Accuracy

pH

0-14

0.01pH

0.02pH

Temperature:

-5 to 105C

0.1C

0.5C

MV

0.1 to 199.9 mV / 0 to 1999 mV

0.2 mV / 2mV

0.2mV/2 mV

Power:

4 x AAA Batteries

Dimensions:

40 x 195 x 36 mm

Weight:

180g

NOTE: Additional probe required for ORP (mV) measurements - sold separately

www.accepta.com

54

Section 6.10
Borescope/Wireless Inspection Camera - BR200/BR250
Cooling tower fill Pack, Ductwork & Calorifier Monitoring
Each Kit comes complete with:

4 x AA Batteries

Rechargeable Display Battery

Micro SD Card Memory card with SD Adapter

USB Cable

Video Interconnect Cable

AC Adapter

Magnetic Base stand and hard case

We offer two affordable Borescopes


The BR200 has a 17mm diameter camera head with a length of 1 meter which can be extended by
use of up to 2 extension cables each of 0.96m.
The BR250 has a 9mm diameter camera head with a length of 0.9 meter which cannot be extended.
Both cameras have a detachable wireless colour display which can be viewed at 10m from the
source and all images/video can be transferred to your PC via the microSD card (with included SD
adaptor) or the USB cable (included) and viewed using Windows Media Player.
The 9mm (BR250) and 17mm (BR200) cameras are waterproof and have 4 LED lamps with dimmer
to illuminate the viewed object with a glare free close up field of view. The gooseneck cable retains
its configured shape.

A memory card is included


for
capturing
JPEG
images and video (AVI)
with day time stamp.

9mm or 17mm diameter


camera head with flexible
gooseneck cable with 4 built in
bright LED lights which easily
illuminate dark areas.

The detachable wireless


3.5 colour TFT LCD screen
can be viewed form remote
location up to 10m from the
source.

Order Options:
BR200 - 17mm diameter Borescope
BR250 - 9mm diameter Borescope
BR200-EXT - BR200 Borescope Extension Cable

www.accepta.com

55

Section 7.0
Drop Test Kits

www.accepta.com

56

Section 7.1
Drop Test Kits
Acceptas high quality drop test kits are available in a range of parameter specific options to suit most analysis requirements. Each self contained kit is housed in its own rugged case and comes complete with
titration bottle, 65ml reagents, tablets or powders; a crushing rod (if required) and an easy to follow waterproof instruction manual.
Each drop test kit or replacement reagent pack includes reagents
necessary to perform between 100 and 200 tests.
Replacement reagents are available, refer to back of catalogue.
Parameter

Range

Order Code

Acid Strength

0-25%

Drp19079

Cleaning Acid Strength Tablets (100pk)

Dt1025

pH Test Strips 0-14 (100pk)

Str6022

Acidity

50-20,000

Drp19001

PA1 (65ml)

Dt1001

ACD2 (65ml)

Dt1002

ACD3 (65ml)

Dt1003

Alkalinity P

5-2400

Drp19002

PA1 (65ml)

Dt1001

PA2/TA2 (65ml)

Dt1005

TA3 (65ml)

Dt1006

Alkalinity M

5-2400

Drp19003

PA2/TA2 (65ml)

Dt1005

TA3 (65ml)

Dt1006

TA4 (65ml)

Dt1004

Alkalinity OH

5-2400

Drp19004

PA1 (65ml)

Dt1001

PA2/TA2 (65ml)

Dt1005

PA3 (65ml)

Dt1007

TA3 (65ml)

Dt1006

Alkalinity P, M & OH

5-2400

Drp19005

PA1 (65ml)

Dt1001

PA2/TA2 (65ml)

Dt1005

PA3 (65ml)

Dt1007

TA3 (65ml)

Dt1006

TA4 (65ml)

Dt1004

Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.

www.accepta.com

57

Section 7.1
Drop Test Kits (continued)
Parameter

Range

Order Code

Anionics (As Sodium Lauryl Sulphate)

5-2000

Drp19006

P1/M (50ml)

Dt1012

P2/3 (65ml)

Dt1013

P9 (65ml)

Dt1014

P10 (65ml)

Dt1015

Bromine Total

0-20

Drp19007

TBR1 (65ml)

Dt1016

TBR2 (65ml)

Dt1017

Carbohydarzide

5-50

Drp19074

CZ1 (65ml)

Dt1652

CZ2 (65ml)

Dt1653

Carbon Dioxide

10-300

Drp19073

PA1 (65ml)

Dt1001

CDX2 (65ml)

Dt1646

Chelant (Free) (as EDTA)

10-240

Drp19053

FC1 (65ml)

Dt1018

FC2 (65ml)

Dt1019

FC3 (65ml)

Dt1020

Chelant LR (Total) (as EDTA)

10-240

Drp19008

CT2 (65ml)

Dt1022

P1/4 Tablets (50pk)

Dt1074

Chloride LR & HR

0-3000

Drp19009

BC1/CC1 (65ml)

Dt1023

BC2 (65ml)

Dt1024

CC2 (65ml)

Dt1024

Chlorine LR & HR (Free)

0-300

Drp19010

FCL1 (65ml)

Dt1027

FCL2 (65ml)

Dt1028

FCL3 (65ml)

Dt1029

Chlorine Dioxide ULR

0.05-1.0

Drp19072

CD4 (40g)

Dt1077

CD5 (40g)

Dt1292

CD6 (20g)

Dt1293

CD7 (65ml)

Dt1114

Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.

www.accepta.com

58

Section 7.1
Drop Test Kits (continued)
Parameter

Range

Order Code

Chlorine Dioxide VLR

0-12

Drp19011

CD01 (65ml)

Dt1036

CD02A (65ml)

Dt1122

Chlorine Dioxide LR

0-24

Drp19012

CD01 (65ml)

Dt1036

CD02 (65ml)

Dt1037

CD02A (65ml)

Dt1122

Chlorine Dioxide VLR-HR

0-600

Drp19013

CD01 (65ml)

Dt1036

CD02 (65ml)

Dt1037

CD02A (65ml)

Dt1122

CD03 (65ml)

Dt1038

Hardness Stop/Go

0-4

Hardness Stop/Go Solution (65ml)


Hardness Yes/No

Dt1129
0-20

Yes/No Hardness Tablets (50pk)


Hardness Calcium

Drp19014S

Drp19014T
Dt1121

5-1200

Drp19015

CH2 (65ml)

Dt1043

CH1P (20g)

Dt1050

H/TH4/CH3 (65ml)

Dt1049

TH3 (65ml)

Dt1044

Hardness Total

5-1200

Drp19016

TH3 (65ml)

Dt1044

TH2 (65ml

Dt1046

TH5 (65ml)

Dt1047

H/TH4/CH4

Dt1049

Hardness Calcium & Total

5-1200

Drp19043

CH2 (65ml)

Dt1043

TH2 (65ml

Dt1046

CH1P (20g)

Dt1050

TH5 (65ml)

Dt1047

H/TH4/CH3 (65ml)

Dt1049

TH3 (65ml)

Dt1044

Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.

www.accepta.com

59

Section 7.1
Drop Test Kits (continued)
Parameter

Range

Order Code

Hydrogen Peroxide LR

1-100

Drp19051

HP1 (65ml)

Dt1051

HP3 (65ml)

Dt1053

Hydrogen Peroxide HR

10-5000

Drp19017

HP1 (65ml)

Dt1051

HP2 (65ml)

Dt1052

Hydrogen Peroxide LR & HR

5-5000

Drp19054

HP1 (65ml)

Dt1051

HP2 (65ml)

Dt1052

HP3 (65ml)

Dt1053

Hypochlorite (Sodium)

0-15%

Drp19060

CL1P (20g)

Dt1030

CL2A (50pk)

Dt1031

CL5 (65ml)

Dt1035

CL2B (10g)

Dt1032

Iron VHR

50-6000

Drp19033

HFE1 (65ml)

Dt1055

HFE2 (65ml)

Dt1056

HFE3 (20g)

Dt1057

HFE4 (65ml)

Dt1058

Molybdate LR

0-50

Drp19018

MB1 (65ml)

Dt1063

MB2 (5g)

Dt1064

MB3 (65ml)

Dt1065

Nitrite

10-2000

Drp19020

N1 (65ml)

Dt1072

N2 (65ml)

Dt1073

Peracetic Acid

10-6000

Drp19045

CL2A (50pk)

Dt1031

CL2B (10g)

Dt1032

HP1 (65ml)

Dt1051

CL7 (65ml)

Dt1054

pH

4-12

Universal pH Indicator

Drp19022
Dt1164

Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.

www.accepta.com

60

Section 7.1
Drop Test Kits (continued)
Parameter

Range

Order Code

Phosphonate (Short) (HEDP & AMP or PBSAM)

0-20

Drp19023

P1/4 Tablets (50pk) or

Dt1074

P1/4L (65ml)

Dt1260

P5 (65ml)

Dt1075

Phosphonate (S/Long) (HEDP & AMP or PBSAM)


(Use in areas where the Alkalinity is greater than
500ppm)

0-20

Drp19059

P1/2 (65ml)

Dt1514

P3 (65ml)

Dt1080

P4 Tablets (100pk) or

Dt1080

P4L (65ml

Dt1291

P5 (65ml)

Dt1075

Phosphonate (PBTC)

0-50

Drp19032

PO1 (65ml)

Dt1351

PO2 (65ml)

Dt1352

PO3 (65ml)

Dt1353

Polyacrylate & Total Polymer

0-20

Drp19025

A1 (65ml)

Dt1082

A2 (65ml)

Dt1083

A3 (100ml)

Dt1087

A4 (65ml)

Dt1084

A5 (65ml)

Dt1085

A6 (65ml)

Dt1086

25mm Filter Holder

Eq5044

0.45 filter papers (50pk)

Eq5061

Polyamine (as CTAB)

0-20

Drp19026

P1/M (50ml)

Dt1012

P2/3 (65ml)

Dt1013

P4/2 (65ml)

Dt1088

QAC (cationic)

0-1000

Drp19027

QA1 (65ml)

Dt1089

QA2 (65ml)

Dt1090

QA3 (65ml

Dt1091

Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.

www.accepta.com

61

Section 7.1
Drop Test Kits (continued)
Parameter

Range

Order Code

Sulphite

5-300

Drp19028

S1 (40g)

Dt1092

S2 (65ml)

Dt1093

Silver

0-60

Drp19080

Silver Reagent (40g)

Dt1727

Silver Indicator (65ml)

Dt1728

Tannin

5-200

Drp19029

TN1 (40g)

Dt1094

TN2 (65ml)

Dt1095

Total Oxidant

0.02-6.0

Drp19030

TO1 (65ml)

Dt1213

TO2 (40g)

Dt1214

TO3 (40g)

Dt1215

TO4 (65ml)

Dt1216

Zinc

0-5

Drp19031

Z1 (65ml)

Dt1096

Z4T (50pk)

Dt1101

Z5 (65ml)

Dt1097

Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.

www.accepta.com

62

Section 8.0
MiniKits

www.accepta.com

63

Section 8.1
MiniKits
Acceptas high quality MiniKits are available in a range of parameter
specific options to suit most analysis requirements.
Each self contained kit is housed in its own rugged case and comes
complete with 30ml reagents, tablets or powders; a test bottle and easy
to follow waterproof instructions. Each kit will perform between 30 and
50 tests.
Additional parameters and replacement reagents are also available,
please refer to Replacement Reagents section.
Parameter

Range

Order Code

Acidity

5-6000

Min41001

PA1 (30ml)

Dt1001

ACD3 (30ml)

Dt1003

Alkalinity P

5-2000

Min41002

PA1 (30ml)

Dt1001

TA3 (30ml)

Dt1006

Alkalinity M

5-2000

Min41003

TA3 (30ml)

Dt1006

TA4 (30ml)

Dt1004

Alkalinity OH

5-2000

Min41004

PA1 (30ml)

Dt1001

PA3 (30ml)

Dt1007

TA3 (30ml)

Dt1006

Bromine Total

0-20

Min41005

TBR1 (30ml)

Dt1016

TBR2 (30ml)

Dt1017

Chelant Total

0-240

Min41006

P1/4L (30ml)

Dt1260

CT2 (30ml)

Dt1022

Chloride LR

5-200

Min41007

BC1/CC1 (30ml)

Dt1023

CC2 (30ml)

Dt1024

Chloride HR

100-3000

Min41008

BC1/CC1 (30ml)

Dt1023

BC2 (30ml)

Dt1026

Chlorine LR

2-30

Min41009

FCL1 (30ml)

Dt1027

FCL2 (30ml)

Dt1028

Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.

www.accepta.com

64

Section 8.1
MiniKits (continued)
Parameter

Range

Order Code

Hardness Calcium

10-1200

Min41012

CH2 (30ml)

Dt1043

H/TH4/CH3 (30ml)

Dt1049

CH1P (10g)

Dt1050

Hardness Total

10-1200

Min41013

TH2 (30ml)

Dt1046

H/TH4/CH3 (30ml)

Dt1049

TH5 (30ml)

Dt1047

Hydrogen Peroxide

10-5000

Min41022

HP1 (30ml)

Dt1051

HP2 (30ml)

Dt1052

Molybdate

0-500

Min41027

MLB1 (30ml)

Dt1440

MLB2 (30ml)

Dt1441

Nitrite

0-2000

Min41014

N1 (30ml)

Dt1072

N2 (30ml)

Dt1073

pH

0-14

Universal pH Solution (30ml)


Phosphonate

Min41016
Dt1164

0-20

Min41017

P1/4L (30ml)

Dt1260

P5 (30ml)

Dt1075

Sulphite

5-200

Min41018

S1 (20g)

Dt1092

S2 (30ml)

Dt1093

Tannin

10-300

Min41019

TN1 (20g)

Dt1094

TN2 (30ml)

Dt1095

QAC Cationics

0-1000

Min41020

QA1 (30ml)

Dt1089

QA2 (30ml)

Dt1090

QA3 (30ml)

Dt1091

Zinc

0-2

Min41021

Z1 (30ml)

Dt1096

Z4T (30pk)

Dt1101

Z5 (30ml)
Dt1097
Individual Replacement Components & complete Replacement Packs are available for each
of the above parameters.

www.accepta.com

65

Section 9.0
Comparator Test Kits

www.accepta.com

66

Section 9.1
Comparator Test Kits
Acceptas high quality comparator test kits are available in a range
of parameter specific options to suit most analysis requirements.
Each self contained kit is housed in its own rugged case and comes
complete with a high quality plastic comparator, comparator disk,
reagents, liquids, tablets or powders; 2 x 10ml plastic cells, a tablet
crusher (if required) and an easy to follow waterproof instructions.
Each comparator test kit or replacement reagent pack includes
reagents necessary to perform between 50 and 100 parameter
specific tests.
Parameter

Range

Order Code

Aluminium

0-0.3

Com81001

Aluminium Disk

256200

Aluminium No1 Tablets (50pk)

Dt1147

Aluminium No2 Tablets (50pk)

Dt1148

Amine

0-15

Com81060

Amine Disk

255005

Amine Indicator Solution (65ml)

Dt1643

Amine Buffer Solution (65ml)

Dt1644

Amine Solvent (100ml)

Dt1645

Ammonia

0-1

Com81002

Ammonia Disk

256210

Ammonia No1 Tablets (50pk)

Dt1245

Ammonia No2 Tablets (50pk)

Dt1244

Bromine

0-5

Com81003

Bromine Disk

256280

DPD No1 Tablets (50pk)

Dt1106

DPD Nitrite Powder (20g)

Dt1295

Bromine (Liquid)

0-5

Com81003L

Bromine Disk

256280

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD Nitrite Powder (20g)

Dt1295

Carbohydrazide LR

0-0.65

Com81049

Carbohydrazide LR Disc

255011

Carbohydrazide LR Solution (65ml)

Dt1654

Carbohydrazide LR Indicator (65ml)

Dt1741

Individual Replacement Components & complete Replacement Packs are available for each
of the above parameters.

www.accepta.com

67

Section 9.1
Comparator Test Kits (continued)
Parameter

Range

Order Code

Chlorine VLR

0-1

Com81004

Chlorine VLR Disc

256010

DPD No1 Tablets (50pk)

Dt1106

DPD No3 Tablets (50pk)

Dt1107

Chlorine VLR (Liquid)

0-1

Com81004L

Chlorine VLR Disc

256010

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD No3 Solution C (30ml)

Dt1507

Chlorine LR (Free & Total)

0-4

Com81005

Chlorine LR Disc

256020

DPD No1 Tablets (50pk)

Dt1106

DPD No3 Tablets (50pk)

Dt1107

Chlorine LR (Liquid)

0-4

Com81005L

Chlorine LR Disc

256020

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD No3 Solution C (30ml)

Dt1507

Chlorine HR (Total)

10-300

Com81006

Chlorine HR Disc

256030

Chlorine HR Reagent (65ml)

Dt1179

Acidifying Solution (65ml)

Dt1180

Chlorine LR & HR

0-4/10-300

Com81028

Chlorine LR Disc

256020

Chlorine HR Disc

256030

DPD No1 Tablets (50pk)

Dt1106

DPD No3 Tablets (50pk)

Dt1107

Chlorine HR Reagent (65ml)

Dt1179

Chlorine Acidifying Solution (65ml)

Dt1180

Chlorine Dioxide

0-2

Com81044

Chlorine Dioxide LR Disc

256331

DPD No1 Tablets (50pk)

Dt1106

DPD Glycine Tablets (50pk)

Dt1146

Individual Replacement Components & complete Replacement Packs are available for each
of the above parameters.

www.accepta.com

68

Section 9.1
Comparator Test Kits (continued)
Parameter

Range

Order Code

Chlorine Dioxide & Total Oxidant (Liquid)

0-2

Com81044LT

Chlorine Dioxide LR Disc

256331

DPD No1 Solution A (30ml)

Dt1505

DPD No1 Solution B (30ml)

Dt1506

DPD No3 Solution C (30ml)

Dt1507

DPD Glycine Solution (30ml)

Dt1525

DPD Neutralising Solution (30ml)

Dt1670

DPD Acidifying Solution (30ml)

Dt1671

Copper LR (Free)

0-1

Com81008

Copper LR Disc

256230

Copper/Zinc LR Tablets (50pk)

Dt1149

Copper HR (Free & Total)

0-5

Com81010

Copper HR Disc

256430

Copper No1 Tablets (50pk)

Dt1240

Copper No2 Tablets (50pk)

Dt1239

Copper LR (Free) & HR (Free & Total)

0-5

Com81034

Copper LR Disc

256230

Copper HR Disc

256430

Copper/Zinc LR Tablets (50pk)

Dt1149

Copper No1 Tablets (50pk)

Dt1240

Copper No2 Tablets (50pk)

Dt1239

DEHA

0-0.5

Com81011

DEHA Disc

256370

DEHA Indicator Solution (65ml)

Dt1739

DEHA Test Solution (65ml)

Dt1166

Hydrogen Peroxide

0-100

Com81053

Hydrogen Peroxide Disc

255040

Hydrogen Peroxide HR Tablets (50pk)

Dt10672

Acidifying PT Tablets (50pk)

Dt1673

Iron LR

0-1

Com81012

Iron LR Disc

256220

FE5 (65ml)

Dt1110

* For accurate soluble Iron determination, filtration is required with 0.45 micron filter papers,
filtration pack is available to order separately.
Individual replacement components & Complete Replacement Packs are available for each of
the above parameters

www.accepta.com

69

Section 9.1
Comparator Test Kits (continued)
Parameter

Range

Order Code

Iron LR (Total)

0-1

Com81012T

Iron LR Disc

256220

FE5 (65ml)

Dt1110

50% Sulphuric Acid (65ml)

Dt1155

Iron LR (Total & Soluble)

0-1

Com81012F

Iron LR Disc

256220

FE5 (65ml)

Dt1110

50% Sulphuric Acid (65ml)

Dt1155

25mm Filter Holder

Eq5044

0.45 Micron Filter papers (50pk)

Eq5061

Iron MR

0.5-5

Com81056

Iron MR Disk

255050

FE9 (65ml)

Dt1723

* For accurate soluble Iron determination, filtration is required with 0.45 micron filter papers,
filtration pack is available to order separately.
Iron MR (Total)

0.5-5

Com81056T

Iron MR Disc

255050

FE9 (65ml)

Dt1723

50% Sulphuric Acid (65ml)

Dt1155

Iron MR (Total & Soluble)

0.5-5

Com81056F

Iron MR Disc

255050

FE9 (65ml)

Dt1723

50% Sulphuric Acid (65ml)

Dt1155

25mm Filter Holder

Eq5044

0.45 Micron Filter papers (50pk)

Eq5061

Iron HR

0.5-10

Com81013

Iron HR Disc

256320

FE10 (65ml)

Dt1247

* For accurate soluble Iron determination, filtration is required with 0.45 micron filter papers,
filtration pack is available to order separately.
Iron HR (Total)

0.5-10

Com81013LT

Iron HR Disc

256320

FE10 (65ml)

Dt1247

50% Sulphuric Acid (65ml)

Dt1155

Individual replacement components & Complete Replacement Packs are available for each of
the above parameters

www.accepta.com

70

Section 9.1
Comparator Test Kits (continued)
Parameter

Range

Order Code

Iron HR (Total & Soluble)

0.5-10

Com81040

Iron HR Disc

256320

FE10 (65ml)

Dt1247

50% Sulphuric Acid (65ml)

Dt1155

25mm Filter Holder

Eq5044

0.45 Micron Filter papers (50pk)

Eq5061

Iron LR & HR (Total & Soluble)

0-1/0.5-10

Com81027F

Iron LR Disc

256220

Iron HR Disc

256320

FE5 (65ml)

Dt1110

FE10 (65ml)

Dt1247

50% Sulphuric Acid (65ml)

Dt1155

25mm Filter Holder

Eq5044

0.45 Micron Filter papers (50pk)

Eq5061

Molybdate

0-100

Com81016

Molybdate Disc

245290

Molybdate HR Reagent (65ml)

Dt1127

Molybdate VHR

0-500

Com81038

Molybdate VHR Disc

245295

Molybdate HR Reagent (65ml)

Dt1127

Nitrate HR

10-100

Com81018

Nitrate HR Disc

255060

Nitrate HR Powder (40g)

Dt1748

Ozone

0-1

Com81020

Ozone (DPD) Disc

256275

DPD Glycine Tablets (50pk)

Dt1146

DPD No4 Tablets (50pk)

Dt1248

pH

4-10

Com81021

pH Universal Disc

256130

Universal pH Indicator (65ml)

Dt1164

Phosphate LR

0-4

Com81022

Phosphate LR Disc

256240

CRP Reagent (65ml)

Dt1236

Ascorbic Acid (10g)

Dt1237

Individual replacement components & Complete Replacement Packs are available for each of
the above parameters

www.accepta.com

71

Section 9.1
Comparator Test Kits (continued)
Parameter

Range

Order Code

Phosphate HR

0-80

Com81023/Com81023L

Phosphate HR Disc

256250

PB1 (65ml)

Dt1111

PB2 (65ml) or

Dt1112

Phosphate HR Tablets (50pk)

Dt1163

Phosphate HR (With Filtration) (Tablets)

0-80

Com81023TF

Phosphate HR Disc

256250

Phosphate HR Tablets (50pk)

Dt1163

25mm Filter Holder

Eq5044

GF/C Filter Papers (50pk)

Eq5048

Phosphate HR (With Filtration) (Liquid)

0-80

Com81023LF

Phosphate HR Disc

256250

PB1 (65ml)

Dt1111

PB2 (65ml)

Dt1112

25mm Filter Holder

Eq5044

GF/C Filter Papers (50pk)

Eq5048

Silica LR

0.25-4

Com81025P

Silica LR Disc

256350

Silica Reagent 1 (65ml)

Dt1233

Silica Reagent 2 (65ml)

Dt1234

Silica Reagent (20g)

Dt1235

Silica HR

0-100

Com81050

Silica HR Disc

256351

Silica HR Powder 1 (20g)

Dt1735

Silica HR Powder 2 (60g)

Dt1736

Silica HR Powder3 (10g)

Dt1737

Tannin (Tannic Acid)

0-20

Com81066

Tannin Disc

256090

Tannin Reagent 1 (65ml)

Dt1181

Tannin Reagent 2 (30ml)

Dt1249

Zinc

0-1

Com81026

Zinc LR Disc

256340

Copper/Zinc LR Tablets (50pk)

Dt1149

EDTA Tablets (30pk)

Dt1205

Dechlor Tablets (30pk)

Dt1206

Individual replacement components & Complete Replacement Packs are available for each of
the above parameters

www.accepta.com

72

Section 10.0
Titration Tests

www.accepta.com

73

Section 10.1
Titration Tests
The Brand Titration Gun has been designed to allow very
accurate testing of key parameters important in the chemical
treatment programme.
The titration gun uses a special syringe fixed to a 3 way valve
that has the titration dispensing tube and a screw connection
for the 20ml titration cartridge.
The Titration Gun has 5 settings allowing you to change the
amount of titrant you put in to the sample, giving you greater
accuracy in the results you obtain.

Parameter

Range

Alkalinity P, M & OH

0-2000

Order Code

Alkalinity Cartridge (20ml)

Crt91002

PA1 (65ml)

Dt1001

TA4 (65ml)

Dt1004

PA3 (65ml)

Dt1007

Chloride

0-2000

Chloride Cartridge (20ml)

Crt91003

BC1/CC1 (65ml)

Dt1023

P3 (65ml)

Dt1080

Hardness Calcium & Total

0-2000

Hardness HR Cartridge (20ml)

Crt91007

CH2 (65ml)

Dt1043

TH2 (65ml)

Dt1046

TH5 (65ml)

Dt1047

CH1P (20g)

Dt1050

Nitrite

0-2000

Nitrite Cartridge (20ml)

Crt91009

N1 (65ml)

Dt1072

50% Sulphuric Acid (65ml)

Dt1155

Phosphonate

0-50

Phosphonate Cartridge (20ml)

Crt91004

P1/2 (65ml)

Dt1514

P3 (65ml)

Dt1080

P4L (65ml)

Dt1291

www.accepta.com

74

Section 10.1
Titration Tests (continued)
Parameter

Range

Sulphite

0-150

Order Code

Sulphite Cartridge (20ml)

Crt91005

S1 (40g)

Dt1092

Zinc

0-10

Zinc Cartridge (20ml)

Crt91008

Z1 (65ml)

Dt1096

Z4T (50pk)

Dt1101

Brand Digital Titration Gun with Bracket

Eq5022

Individual replacement components & Complete Replacement Packs are available for each of
the above parameters.

Alternative Titrator Systems:


We offer other types of pipette titration systems and replacement cartridges for Hach and Ranin,
please ask for details.

www.accepta.com

75

Section 11.0
Test Strips

www.accepta.com

76

Section 11.1
Test Strips
Test papers and strips are used for semi-quantitative determinations of
ions and chemical substances.
They provide the information whether a given component is present at or
above the defined limit of detection. All of our Test Strips come in a
plastic container holding either 25, 50 or 100 individual tests.
The indicator pads on pH strips are non bleed therefore the colour
change remains far longer and readable until the pad is dry.
The strips have a long shelf life and are easy to use.

Parameter

Range

Scale

Code

Ammonia

0-5

0, 0.2, 1, 2, 5
(25 strips per pack)

Str6001

Chlorine Free

0-6

0, 0.05, 0.1, 0.2 0.4, 0.6, 0.8, 1.2, 1.5, 2.0,


2.6, 4.0,>6.0 (50 strips per pack)

Str6004

Chlorine Total

0-10

0, 0.05, 0.1, 0.15, 0.2, 0.5, 0.8, 1.0, 4.0, 10.0


(50 strips per pack)

Str6005

Chlorine Test Strips

0-200

10, 50, 100, 200


(100 strips per pack)

Str6006

Chlorine Dioxide LR

0-1.6

a) 0, 0.1, 0.2, 0.4, 0.6, 0.8, 1, 1.2, 1.4, 1.6


b) 0, 0.05, 0.1, 0.15, 0.2, 0.3
(50 strips per pack)

Str6007

Chlorine Dioxide HR

0-100

0.5, 2, 5, 10, 25, 50, 100


(50 strips per pack)

Str6008

Copper

0-2

0, 0.05, 0.1, 0.2, 0.4, 1, 2


(25 strips per pack)

Str6009

Hardness, Total

0-1000

0, 40, 80, 120, 180, 250, 425, 1000


(50 strips per pack)

Str6010

Hardness, Total

0-500

0, 50, 125, 250, 500


(50 strips per pack)

Str6011

Hydrogen Peroxide LR

0-100

0, 0.5, 2.0, 5.0, 10, 25, 50, 100


(50 strips per pack)

Str6012

Hydrogen Peroxide HR

0-400

0, 100, 200, 400


(50 strips per pack)

Str6013

Hydrogen Peroxide HR

0 - 1000

Peroxide 1000 (100 strips per pack)


0, 50, 150, 300, 500, 800, 1000

Str6015

Oil Test Papers

Yes/No

Detection of Oil in Water and / or Soil


(100 strips per pack)

Str6035

Peracetic Acid

0-500

0, 100, 250, 500


(50 strips per pack)

Str6057

5m reel with dispenser

Str6019

Pack of 3 x 5m reels

Str6020

Potassium Iodide Reel


Potassium Iodide Refill

Potassium
Iodide Refill

www.accepta.com

77

Section 11.1
Test Strips (continued)
Parameter

Range

Scale

Code

Potassium Iodide
Starch

5-100

Lower level 5ppm upper level 100ppm


(100 strips per pack)

Str6021

pH

0-6

0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0,
5.5, 6.0 (100 strips per pack)

Str6039

pH

0-14

1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14


(100 strips per pack)

Str6022

pH

6-10

6.0, 6.4, 6.7, 7.0, 7.3, 7.6, 7.9, 8.2, 8.4, 8.6,
8.8, 9.1, 9.5, 10.0 (100 strips per pack)

Str6032

pH

7-10

7, 7.5, 8, 8.5, 9, 9.5, 10.0


(100 strips per pack)

Str6026

pH

7-14

7, 7.5, 8, 8.5, 9, 9.5, 10, 10.5, 11, 11.5, 12,


12.5, 13, 12.5, 14 (100 strips per pack)

Str6027

pH

4.5-10

4.5, 5, 5.5, 6, 6.5, 7, 7.5, 8, 8.5, 9, 9.5, 10


(100 strips per pack)

Str6028

IF THE PARAMETER YOU ARE INTERESTED IN IS NOT LISTED, PLEASE CONTACT US

www.accepta.com

78

Section 12.0
Bacteria Testing

www.accepta.com

79

Section 12.1
Oxidising Biocide Test Kits
Acceptas range of oxidising biocide test kits use the new revolutionary Extech Chlorine Meter, which measures by selective ion
electrometry. The Extech Chlorine Meters are unaffected by
colour, turbidity or organic pollutants.
Each kit includes an Extech CL200 Meter, applicable reagents, test
container and detailed instructions. Each kit will carry out between
100 and 300 tests.
With each parameter you have the option of adding in the pH
probe to be used with the Chlorine Meter allowing for the easy
measurement of pH.
Parameter

Range

Order Code

Chlorine (Free & Total)

0-10

Ox68003

Extech CL200 Meter

CL200

EX1 Reagent (65ml)

Dt1137

EX2 Reagent (65ml)

Dt1135

EX3 Reagent (65ml)

Dt1136

Chlorine Dioxide & Chlorite

0-10

Ox68005

Extech CL200 Meter

CL200

EX1 Reagent (65ml)

Dt1137

EX2 Reagent (65ml)

Dt1135

EX3 Reagent (65ml)

Dt1136

EX5 Reagent (65ml)

Dt1138

EX6 Reagent (65ml)

Dt1139

Chlorine Dioxide, Chlorite & pH

0-10

Ox68006

Extech CL200 Meter

CL200

EX1 Reagent (65ml)

Dt1137

EX2 Reagent (65ml)

Dt1135

EX3 Reagent (65ml)

Dt1136

EX5 Reagent (65ml)

Dt1138

EX6 Reagent (65ml)

Dt1139

Extech pH Probe

Eq5039

pH7 Buffer Solution (65ml)

Dt1118

pH10 Buffer Solution (65ml)

Dt1161

Note: Ox68003 test kit can be used for determining bromine level as a factor of the detected chlorine
level.
Individual replacement components & complete replacement packs are available for each of
the above parameters.

www.accepta.com

80

Section 12.2
Non-Oxidising Biocide Test Kits
Measuring non oxidising biocides is crucial in ensuring that the
biocide in use is not over or under dosed and these non oxidising
biocide test kits are ideal for this application.
Each kit contains all the necessary reagents to carry out between
50 and 100 tests and uses either a colour card or drop count to
determine the reserve.
These test kits can be used to determine the level of biocides in
Open & Closed water systems and can be used when dosing
biocides to systems recently pre-commissioned cleaned.

Parameter

Range

Order Code

Isothiazolone

0-7.5

NOx68001

dK1 (30ml)

Dt1254

dK2 (65ml)

Dt1255

dK3 (65ml)

Dt1256

dK4 (65ml)

Dt1257

dK5 (30ml)

Dt1258

THPS

0-20

NOx68003

0.1N Iodine Solution (100ml)

Dt1162

DSP Solution (250ml)

Dt1204

PSSA Solution (65ml)

Dt1021

Starch Indicator (40g)

Dt1207

DBNPA

0-6.8

NOx68005

DPD No1 Tablets (50pk)

Dt1106

DPD No3 Tablets (50pk)

Dt1107

DBN4 pH adjuster (65ml)

Dt1572

Glutaraldehyde

12.5-1600

NOx68006

GL1 (5g)

Dt1605

GL2 (65ml)

Dt1606

PA1 (65ml)

Dt1001

0.05M / 0.1N Sulphuric Acid (65ml)

Dt1384

Sodium Hydroxide 0.1M / 0/1N (65ml)

Dt1453

Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.

www.accepta.com

81

Section 12.3
ATP Meters & Swabs
ATP (adenosine triphosphate) is present in all organic material and is the
universal unit of energy used in all living cells.
ATP is produced and/or broken down in metabolic processes in all living
systems. Processes such as photosynthesis in plants, muscle contraction
in humans, respiration in fungi and fermentation in yeast are all driven by
ATP. Therefore, most foods, water and microbial cells will contain some
level of naturally occurring ATP.
The SystemSURE Plus Luminometer (in conjunction with the Aquasnap or
Ultrasnap ATP swabs) uses bioluminescence to detect residual ATP as
an indicator of water quality (Aquasnap) or surface cleanliness
(Ultrasnap).
The presence of ATP indicates the presence of contamination in water
and on surfaces, including food residue, allergens and/or bacteria. This
implies a potential for the support of bacterial growth.

systemSURE PLUS - Key Features

Simple to use three step test


Lightweight, handheld and durable
250 programmable test points per test plan
20 programmable test plans
Alphanumeric ID of locations
Stores 2000 results
Programmable user IDs
Self-calibration at start up
Detects down to 1 femtomole (1 x 10-16 moles) of ATP

systemSURE PLUS - Instrument Design

Small, lightweight, handheld instrument (0.22kgs, 7 x 18 x 3 cm)


Durable outside shell, sealed keypad to battle against splashes
and the environment
Advanced photodiode technology
AA battery powered (lasts up to 3000+ tests)
PC compatible via RS232 cable or USB
Simple to use, menu-driven operation from keypad
Engineered for durability and intensive use

Equipment

Goods

Code

SystemSURE Plus

ATP meter, case, data lead, data analysis software

SSP/1

Ultrasnap ATP surface


testing device - swabs

100 pens for ATP with Extractant included in each pen US202

Aquasnap ATP water


testing device - pens

100 pens for Total ATP with Extractant included in


each pen

AQ100

Aquasnap ATP water


testing device - pens

100 pens for Free ATP with Extractant included in


each pen

AQ200

www.accepta.com

82

Section 12.4
Dip-slides & Tube Tests
For Aerobic & Anaerobic Bacteria
Delivering simplicity and affordability through
innovation.
A Dip-slide is a means of testing the microbial content of liquids
or surfaces. It consists of a plastic carrier bearing a sterile culture
medium which can be dipped in a liquid or swabbed on a surface
to be sampled. It is then incubated for 48 hours at 30 to allow
microbial growth.
The resulting microbial colonies are estimated by reference to a
comparison chart. If the treatment programme is effective the
Dip-slide count will be consistently low (<103). If a high result is
obtained the test should be repeated and the treatment
programme checked.
Dip-slides/Tube Tests are supplied in boxes of 10 and come with
instructions to determine the activity of aerobic & anaerobic
bacteria.
The Tube Tests monitor two types of anaerobic bacteria, namely
SRB (Sulphate reducing) & NRB (Nitrite reducing) bacteria found
in closed water systems and are incubated at 35 for 5 days.

Part Code:

Media Side 1 & 2: Detection of:

Ds84001

TTC/TTC

Total viable bacteria (TVC) in


waters & on surfaces

Ds84002

TTC/MALT

TVC/Yeasts & Moulds in waters & on surfaces

Ds84003

TTC/ROSE

TVC/Yeasts & Moulds found


mainly in the food
industry

Ds84004

TTC/MAC

TVC/Coliforms &
Ps.aeruginosa

Ds84005

TTC/Chromogenic TVC/E.coli, Coliforms &


Ps.aeruginosa

Ds84006

CET/MAC

Ps.aeruginosa
& Enterobacteriaceae

Ds84007

TTC/PDM

TVC & Pseudomonas


species

Ds84008

SRB Tube Test

Sulphate reducing bacteria


(SRB)

Ds84009

NRB Tube Test

Nitrite reducing bacteria


(NRB)

Note - All dipslides can be own labelled. Please contact us


for further details.

Dip-slide/Tube Test Disposal


Refer to our Technical Document detailed: Application, Storage & Disposal which can be found in the
download section of our website. Only used Dip-slides are hazardous.

www.accepta.com

83

Section 12.5
Incubators
We have a range of high quality incubators designed to suit most applications from site based to
highly portable units. Apart from the factory pre-set Incubator2 all of our incubators have a temperature gauge which allows easy temperature adjustment and monitoring.
The Incubator8P and Incubator45 incubators come complete with 12v car lead.
Note: To use the Incubator2 & Incubator20 in a car an additional cable is required which can be purchased on request.

Incubator2 Order
Code: Eq5057
Incubator8 - 8 Slide

Incubator8P - 8 Slide
Order Code: Eq5055
Incubator18 - 18 Slide
Order Code: Eq5059

Incubator20 - 20 Slide
Order Code: Eq5052

Incubator45 - 45 Slide
Order Code: Eq5093

www.accepta.com

84

Section 12.6
Universal Rapid Legionella Test Kit
UNIVERSAL RAPID LEGIONELLA KIT (RLeg60050)
Acceptas Universal Rapid Legionella Test Kit is a breakthrough in technology for the on site rapid
detection of legionella pneumophila serogroup 1. The kit uses an immunochromatographic assay to
detect within 30 minutes the presence of cell surface antigens from Legionella pneumophila
serogroup 1 (SG1).
The presence of the antigen in the water causes the test line to turn red in colour. A control line
is included which should always turn red if the test has been performed correctly. As the kit is
fully portable it can be used in any water system such as cooling towers, water services, spas,
pools, showers & sprinklers.
Our Universal Rapid Legionella Test Kit can detect with high sensitivity to 100 cfu/l if Legionella
pneumophila SG1 is present in water within 30 minutes and is ideal when access to laboratories is
impractical or speed is imperative.

The Universal Rapid Legionella test Kit


(RLeg60050) should be used as a rapid test
to determine if Legionella sero group 1 is
present within 30 minutes and should be
used to supplement your existing sampling
programme and should not replace routine
laboratory sampling.

FIVE EASY STEPS IN 30 MINUTES


Sample

Filter

Recover

Description

No. Tests

Code

Application

Universal Legionella Test Kit

RLeg60050

All Water Systems

Universal Legionella Refill Kit

RLeg60050F

Refill for all systems

www.accepta.com

85

Section 12.7
Dipslide Comparator App
For use with Accepta Dip-slides
Acceptas app is available on the Apple and Android
storesfree, and will allow the recording with photographic evidence of dip-slides taken on customer
sites.

Simple to use:
The app provides a simple but effective method of
photographing a dip-slide and then displaying it
adjacent to media specific quantification palettes
which move by finger swipe to allow the operator to
make a direct comparison.
The photograph of the compared dip-slide can then
be e-mailed to one or more e-mail addresses for
easy electronic storage.
Graphs can be viewed of historical results and can
even be emailed to clients.

Additional features include:

Choice of different media specific comparison


quantification palettes to compliment the full
range of Accepta Dip-slides.

Facility to preload as many customer


addresses as required with drop down menus
for easy access

Information screens to provide resolutions to


frequently asked questions.

Automatic graphical analysis of all inputted


data on a site by site basis.

Quick e-mail option for graphical analysis

All photographic results are stored for a 90 day


period prior to automatic deletion.

www.accepta.com

86

Section 13.0
Corrosion Coupon Services

Corrosion Coupons

Coupon Weighing

Corrosion Coupon Racks

Images are for illustration purposes only and may differ from goods supplied

www.accepta.com

87

Section 13.1
Corrosion Coupons & Test Racks
Most corrosion monitoring/testing in water systems is carried out with the
use of corrosion coupons installed in purpose built corrosion test racks.
The actual metals used for monitoring are most commonly mild steel and
copper with copper the next most widely used.
The corrosion coupons used in field testing are generally 4x
manufactured to fit in standard corrosion test racks. The ASTM D-2688
standard, entitled Corrosivity of Water in the absence of Heat Transfer
(Weight Loss Methods) gives much useful information regarding the
corrosion testing of water.
Corrosion test racks (by-pass rigs) are designed to permit easy and
inexpensive monitoring of corrosion within water systems. Part of the
water is diverted from the main flow into the By-Pass rig where it passes
over test coupons and is then returned to the system. The test coupons
can be removed from the rack without the need to close down the
system.
Corrosion Coupon Specification

4 x x 20 gauge

Fixing hole as required

Edges and hole de burred

Material Identified and numbered

Glass bead blast finish

Pre-weighed to four decimal places (i.e. 0.1mg)

Individually packed in heavy duty polythene bags

Materials

Details

Code

Mild Steel

New Spec : EN FePO1


Old Spec : CR4

Cc001

Copper

New Spec : EN CW004A,CW024A


Old Spec : C101/C106

Cc002

Stainless Steel

New Spec : EN 1.4301


Old Spec : 304

Cc003

Aluminium

1200

Cc004

Brass

New Spec : EN CW505L, CW508L


Old Spec : CZ106/108

Cc005

Galvanised Mild Steel

New Spec : EN FePO2


Old Spec : 2989

Cc006

Corrosion Coupon Racks


Designs generally follow the
ASTM standard D-2668.

PVC Quick seal rack for 4 coupons (S type)


PVC Quick seal rack for 2 coupons (S type)
PVC Quick seal rack for 4 coupons (U type)

Cr001
Cr006
Cr004

Inlet & Outlet 1 connections

Mild Steel rack for 4 coupons

Cr002

Coupon Weighing

Any single coupon assessed for corrosion weight.

Cw1008

Note - Must be returned in original shipping


envelope with specification and original weight
information.
(Minimum order value is 2 coupons).

www.accepta.com

88

Section 14.0
PrimeLab (Single or Multi Range) Photometer

For software, brochure and current reagent/parameter information please contact us

www.accepta.com

89

Section 14.1
PrimeLab (Single or Multi Range ) Photometer
(Worlds first expandable photometer)

The PrimeLab Photometer is an easy to use, portable photometer that offers extensive testing
capabilities on a wide range of parameters and systems.

Features & benefits summarised:

The PrimeLab Photometer tests for all major water constituents with over 80 available
parameter methods (future parameter developments available).
PrimeLab is ready-to-use straight out of the box.
PrimeLab can be purchased as a single parameter unit (i.e. for single range/ClO2) but
can easily be expanded to unlock extra parameters at any time in the future.
All PrimeLab methods are pre-programmed for ease of use.
PrimeLab is Bluetooth enabled for easy communication with laptops or computers.
PrimeLab can store up to 100 test results at any one time (on a rolling sequence).
PrimeLab can hold up to 20 site/system IDs at any one time and test results can be
stored directly against these IDs (IDs are changeable as required).
Powerful, yet easy-to-use software allows report generation and trending of results.
PrimeLab uses photometer grade reagents.
PrimeLab offers a one-time blank per sample, saving significant on-site testing time.
Results are displayed directly in units of concentration, typically mg/l or ppm. In many
methods, concentration in alternate chemical forms is also available. For example,
phosphate readings are available as P, PO4 and P2O5. Displayed results can be
changed from one form to the next by using the UP and DOWN scroll arrows on the
display.
4 x AAA batteries provide self-contained power for field testing. A multi voltage mains
adapter is supplied as standard.

www.accepta.com

90

Section 14.1
Electronic Photometer - PrimeLab (continued)

The PrimeLab 1.0 Multitest is the first truly expandable photometer of its kind. The PrimeLab can be
initially purchased as a single range photometer but can at any time in the future be expanded to
accommodate as many additional parameters as required. This allows the user to customise the
PrimeLab for their individual requirements. Small and handy but powerful due to the JENCOLOR
Multi-Colour Sensor. The PrimeLab includes an inbuilt Bluetooth module which allows wireless
connection to your computer to access the powerful PrimeLab Desktop Assistant software package.
The PrimeLab photometer can be supplied in a range of different sized rugged cases with the size
dependent on the number of parameters, reagents & accessories that you require.

Specifications
Spectral Bandwidth:
PC-Connection:
Calibration:
One-Time-Zero:
Internal Memory:
Datum:
Auto-Off:
Menu:
Power:
Display:
Languages:
Environment:
IP Classification:
Dimensions:
Weight:

380nm - 780nm on 7 open channels, each overlapping +/- 40nm


Inbuilt Bluetooth module
Auto-Calibration by JENCOLOR Sensor; Detecting LEDbrightness and adjusting system
Intelligent OTZ - (One-Time-Zero) function, detecting different
ZERO types
100 test results / 20 accounts
RTC (Real Time Clock) and date
User defined, Factory default = 10 minutes
Intuitive, 4-button-menu guided; test instructions which guide you
through test procedures
Choose between 4 x 1.5 V AAA Batteries and/or 100-240V,
50/60Hz, 0.2A-> 5.0V, 1200mA, 6W
Graphic LCD Display / Monochrome
English, Spanish, French & German
5C - 45C / 30 - 90% rel. Humidity
Splash protected
175 x 88 x 59mm
160g

NOTE: Alternative single and multi range photometers are available from Accepta, information available on request.

www.accepta.com

91

Section 14.2
PrimeLab Parameters & Reagents
PrimeLab Photometer

Plp1001

c/w - Medium Plastic Case with Foam, Stirring Rod, 10ml Luer Lock Syringe, Cell Cleaning Brush
4 x 10ml Glass Cells, Light Shield, Bluetooth Dongle, Charger & Manual (No Parameter)
ID

Parameter

Range

PID001

Active Oxygen

0.00-40 ppm

PL DPD No4 Photometer Tablets (50pk)


PID005

Alkalinity M

Plr1158/50
5-200 ppm

PL Total Alkalinity Photometer Tablets (50pk)


PID006

Alkalinity P

Plr1144/50
5-300 ppm

PL Alkalinity P Photometer Tablets (50pk)


PID004

PID002

PID003

PID007

PID008

PID063

PID009

Aluminium

Plr1159/50
0-0.3 ppm

PL Aluminium No1 Photometer Tablets (50pk)

Plr1156/50

PL Aluminium No2 Photometer Tablets (50pk)

Plr1157/50

Ammonia

0-1 ppm

PL Ammonia No1 Tablets (50pk)

Plr1195/50

PL Ammonia No2 Tablets (50pk)

Plr1196/50

Ammonia

TBC

PL Ammonia 1 (40g)

TBC

PL Ammonia 2 (40g)

TBC

Boron

0-2 ppm

PL Boron No1 Tablets (50pk)

Plr1206/50

PL Boron No2 Tablets (50pk)

Plr1207/50

Bromine

0-18 ppm

PL DPD No1 Photometer Tablets (50pk)

Plr1141/50

PL DPD Glycine Tablets (50pk)

Plr1143/50

Bromine

0-18 ppm

PL DPD 1 A (30ml)

Plr1102

PL DPD 1 B (30ml)

Plr1103

PL DPD Nitrite Powder (20g)

Plr1108

Calcium Hardness

50-1000 ppm

PL Calcium Hardness Photometer Tablets (50pk)


PID078

PID071

Order Code

Calcium Hardness

Plr1146/50
0-500 ppm

PL Calcium Hardness No1 Tablets (50pk)

Plr1148/50

PL Calcium Hardness No2 Tablets (50pk)

Plr1149/50

Carbohydrazide

0-1.3 ppm

PL Oxygen Scavenger 1 (30ml)

Plr1112

PL Oxygen Scavenger 2 (30ml)

Plr1113

www.accepta.com

92

Section 14.2
PrimeLab Parameters & Reagents (continued)
ID

Parameter

Range

PID095

Chloramines

0-8 ppm

PID010

PID011

PID012

PID014

PID015

PID016

PID064

Order Code

PL DPD No1 Photometer Tablets (50pk)

Plr1141/50

PL DPD No2 Photometer Tablets (50pk)

Plr1213/50

PL DPD No3 Photometer Tablets (50pk)

Plr1142/50

Chloride

0-5-25 ppm

PL Chloride No1 Photometer Tablets (50pk)

Plr1154/50

PL Chloride No2 Photometer Tablets (50pk)

Plr1155/50

Chlorine

0-8 ppm

PL DPD No1 Photometer Tablets (50pk)

Plr1141/50

PL DPD No3 Photometer Tablets (50pk)

Plr1143/50

Chlorine

0-8 ppm

PL DPD 1 A (30ml)

Plr1102

PL DPD 1 B (30ml)

Plr1103

PL DPD 3 C (30ml)

Plr1104

Chlorine

5-200 ppm

PL Chlorine HR Photometer Tablets (50pk)

Plr1164/50

PL Acidifying GP Photometer Tablets (50pk)

Plr1165/50

Chlorine

0-200 ppm

PL Chlorine HR 1 (30ml)

Plr1109

PL Chlorine HR 2 (30ml)

Plr1110

Chlorine Dioxide

0-15 ppm

PL DPD No1 Photometer Tablets (50pk)

Plr1141/50

PL DPD Glycine Tablets (50pk)

Plr1143/50

Chlorine Dioxide

0-15 ppm

PL DPD 1 A (30ml)

Plr1102

PL DPD 1 B (30ml)

Plr1103

PL DPD Glycine (30ml)

Plr1106

+ Total Oxidant

PID106

PL DPD Acidifying (30ml)

Plr1105

PL DPD Neutralising (30ml)

Plr1107

Chlorite

0-8 ppm

PL DPD 1 A (30ml)

Plr1102

PL DPD 1 B (30ml)

Plr1103

PL DPD Glycine (30ml)

Plr1106

PL DPD Acidifying (30ml)

Plr1105

PL DPD Neutralising (30ml)

Plr1107

www.accepta.com

93

Section 14.2
PrimeLab Parameters & Reagents (continued)
ID

Parameter

Range

PID094

Chromium

0-2.2 ppm

PID103

PID079

PL Chromium No1 Photometer Tablets (50pk)

Plr1210/50

PL Chromium No2 Photometer Tablets (50pk)

Plr1211/50

Chromium

0-1 ppm

PL Chromate 1 (10g)

Plr1188

PL Chromate 2 (65ml)

Plr1189

COD LR

0-150 ppm

MERCK COD LR (16mm)


PID080

Plr1218

COD MR

0-1500 ppm

MERCK COD MR (16mm)


PID017

Plr1219

COD HR

0-15000 ppm

MERCK COD HR (16mm)


PID107

Order Code

Plr1220

Colour

0-500 ppm

No Reagents Required
PID018

PID019

Copper

0.05-5 ppm

PL Copper No1 Photometer Tablets (50pk)

Plr1166/50

PL Copper No2 Photometer Tablets (50pk)

Plr1168/50

Copper

0-5 ppm

PL Copper 1 (20g)
PID020

Plr1111

Cyanuric Acid

2-160 ppm

PL CYA-Test Photometer Tablets (50pk)


PID065

PID082

PID021

PID070

PID072

DBNPA

Plr1145/50
0-13 ppm

PL DPD 1 A (30ml)

Plr1102

PL DPD 1 B (30ml)

Plr1103

PL DPD 3 C (30ml)

Plr1104

DBNPA

0-13 ppm

PL DPD No1 Photometer Tablets (50pk)

Plr1141/50

PL DPD No3 Photometer Tablets (50pk)

Plr1142/50

DEHA

20-1000 ppb

PL Oxygen Scavenger 1 (30ml)

Plr1112

PL Oxygen Scavenger 2 (30ml)

Plr1113

Erythrobic Acid

0-3.5 ppm

PL Oxygen Scavenger 1 (30ml)

Plr1112

PL Oxygen Scavenger 2 (30ml)

Plr1113

Fluoride

0-2ppm

PL Fluoride 1 (65ml)

Plr1114

PL Fluoride 2 (65ml)

Plr1175

www.accepta.com

94

Section 14.2
PrimeLab Parameters & Reagents (continued)
ID

Parameter

Range

PID078

Hardness Calcium

0-500ppm

PID009

PL Calcium Hardness No1 Tablets (50pk)

Plr1148/50

PL Calcium Hardness No2 Tablets (50pk)

Plr1149/50

Hardness Calcium HR

50-1000 ppm

PL Calcium Hardness Photometer Tablets (50pk)


PID057

Hardness Total HR

Plr1146/50
20-500 ppm

PL Total Hardness Photometer Tablets (50pk)


PID056

Hardness Total LR

Plr1150/50
2-50 ppm

PL Total Hardness Photometer Tablets (50pk)


PID023

Hydrazine

Plr1146/50
5-600 ppm

PL Hydrazine 1 (65ml)
PID026

PID024

Plr1115

Hydroquinone

0.2.5 ppm

PL Oxygen Scavenger 1 (30ml)

Plr1112

PL Oxygen Scavenger 2 (30ml)

Plr1113

Hydrogen Peroxide LR

0-3.8ppm

PL Hydrogen Peroxide LR Photometer Tablets


(50pk)
PID066

PID025

PID027

Hydrogen Peroxide LR

Plr1214/50
0-3.8 ppm

PL Hydrogen Peroxide LR 1 (30ml)

Plr1152

PL Hydrogen Peroxide LR 2 (30ml)

Plr1153

Hydrogen Peroxide HR

0-200 ppm

PL Hydrogen Peroxide HR 1 (30ml)

Plr1116

PL Hydrogen Peroxide HR 2 (30ml)

Plr1117

Iodine

0-28 ppm

PL DPD No1 Photometer Tablets (50pk)


PID067

PID028

Order Code

Iodine

Plr1141/50
0-28 ppm

PL DPD 1 A (30ml)

Plr1102

PL DPD 1 B (30ml)

Plr1103

Iron LR

0-1 ppm

PL Iron LR Photometer Tablet (50pk)

Plr1151/50

Filtration pack required


PID029

Iron MR

0-10ppm

PL Iron MR 1 (20g)

Plr1118

Filtration pack required

www.accepta.com

95

Section 14.2
PrimeLab Parameters & Reagents (continued)
ID

Parameter

Range

PID030

Iron HR

0-30ppm

Order Code

PL Iron HR 1 (65ml)

Plr1119

PL Iron HR 2 (30ml)

Plr1120

Filtration pack required


PID093

Magnesium

0-100ppm

PL Magnesium Photometer Tablets


PID031

PID104

PID069

PID096

PID032

PID033

Manganese

Plr1212/50
0.2-5ppm

PL Manganese No1 Tablets (50pk)

Plr1201/50

PL Manganese No2 Tablets (50pk)

Plr1202/50

Manganese

TBC

PL Manganese 1 (65ml)

TBC

PL Manganese 2 (65ml)

TBC

PL Manganese 3 (65ml)

TBC

Methylethylketoxime

0-4.1ppm

PL Oxygen Scavenger 1 (30ml)

Plr1112

PL Oxygen Scavenger 2 (30ml)

Plr1113

Molybdate LR

0-15ppm

PL Molybdate No1 Tablets (2 x 25pk)

Plr1199/50

PL Molybdate No2 Tablets (50pk)

Plr1200/50

Molybdate

1-100ppm

PL Molybdate HR No1 Photometer Tablets (50pk)

Plr1162/50

PL Molybdate HR No2 Photometer Tablets (50pk)

Plr1163/50

Molybdate HR

5-200ppm

PL Molybdate 1 (65ml)
PID099

PID090

PID100

Plr1121

Nickel LR

TBC

PL Nickel LR 1 (50g)

TBC

PL Nickel LR 2 (65ml)

TBC

PL Nickel LR 3 (20g)

TBC

Nickel HR

TBC

PL Nickel HR 1 Photometer Tablets (50pk)

TBC

PL Nickel HR 2 Photometer Tablets (50pk)

TBC

Nickel HR

0-10 ppm

PL Nickel HR 1 (50ml)

Plr1181

PL Nickel HR 2 (30ml)

Plr1182

PL Nickel HR 3 (30ml)

Plr1183

www.accepta.com

96

Section 14.2
PrimeLab Parameters & Reagents (continued)
ID

Parameter

Range

PID034

Nitrate

TBC

PL Nitrate 1 (50g)
PID035

TBC

Nitrite LR

0-0.5ppm

PL Nitrite LR Photometer Tablets (50pk)


PID036

Nitrite HR

Plr1168/50
5-200ppm

PL Nitrite HR 1 (50g)
PID097

PID101

Plr1184

Nitrite HR

TBC

PL Nitriphot No1 Tablets (50pk)

TBC

PL Nitriphot No2 Tablets (50pk)

TBC

Nitrite HR

0-3000 ppm

PL Nitrite HR 2 (65ml)
PID092

PID037

PID098

PID040

Plr1184

Ozone

0-5.4ppm

PL DPD 1 A (30ml)

Plr1102

PL DPD 1 B (30ml)

Plr1103

PL DPD 3 C (30ml)

Plr1104

PL DPD Glycine (30ml)

Plr1106

Ozone

0-5.4ppm

PL DPD No1 Photometer Tablets (50pk)

Plr1141/50

PL DPD No3 Photometer Tablets (50pk)

Plr1142/50

PL DPD Glycine Photometer Tablets (50pk)

Plr1143/50

Phenol

0-5ppm

PL Phenol No1 Photometer Tablets (50pk)

Plr1215/50

PL Phenol No2 Photometer Tablets (50pk)

Plr1216/50

PL Phenol PR Photometer Tablets (50pk)

Plr1217/50

pH LR

TBC

PL Bromocresolpurple Tablets (50pk)


PID038

pH MR

TBC
6.4-8.4

PL Phenol Red Photometer Tablets (50pk)


PID039

pH MR

Plr1147/50
6.4-8.4

PL pH 6.4-8.4 (30ml)
PID041

Plr1125

pH Universal

5-11

PL Universal pH Tablets (50pk)


PID042

Order Code

pH Universal

Plr1194/50
4-11

PL pH 4-11 (65ml)

Plr1126

www.accepta.com

97

Section 14.2
PrimeLab Parameters & Reagents (continued)
ID

Parameter

Range

PID043

PHMB

TBC

PL PHMB Photometer Tablets (50pk)


PID044

PID045

PID046

Phosphate LR

Order Code

TBC
0-4 ppm

PL Phosphate LR No1 Photometer Tablets (50pk)

Plr1191/50

PL Phosphate LR No2 Photometer Tablets (50pk)

Plr1192/50

Phosphate LR

0-4 ppm

PL Phosphate LR 1 (65ml)

Plr1127

PL Phosphate LR 2 (10g)

Plr1128

Phosphate HR

0-80 ppm

PL Phosphate HR No1 Tablets (50pk)

Plr1197/50

PL Phosphate HR No2 Tablets (50pk)

Plr1198/50

Filtration pack required


PID047

Phosphate HR

0-100 ppm

PL Phosphate HR 1 (65ml)

Plr1129

PL Phosphate HR 2 (65ml)

Plr1130

Filtration pack required


PID087

Phosphonate

0-20 ppm

PL Phosphonate 1 (20g)

Plr1169

PL Phosphonate 2 (20g)

Plr1170

PL Phosphonate 3 (65ml)

Plr1171

PL Phosphonate 4 (20g)

Plr1172

Filtration pack required


PID085

PID048

Polyacrylate

1-30 ppm

PL Polyacrylate 1 (65ml)

Plr1139

PL Polyacrylate 2 (65ml)

Plr1140

Potassium

TBC

PL Potassium Photometer Tablet (50pk)


PID083

PID049

QAC

TBC
TBC

PL Acidifying GP Photometer Tablets (50pk)

TBC

PL QAC HR Photometer Tablet (50pk)

TBC

Silica LR

0-5 ppm

PL Silica LR 1 (65ml)

Plr1131

PL Silica LR 2 (65ml)

Plr1132

PL Silica LR 3 (40g)

Plr1133

www.accepta.com

98

Section 14.2
PrimeLab Parameters & Reagents (continued)
ID

Parameter

Range

PID050

Silica HR

0-100 ppm

PID051

PID068

PID054

PL Silica HR 1 (20g)

Plr1134

PL Silica HR 2 (60g)

Plr1135

PL Silica HR 3 (10g)

Plr1136

Sodium Hypochlorite

0.2-40%

PL Chlorine HR Photometer Tablets (50pk)

Plr1164/50

PL Acidifying GP Photometer Tablets (50pk)

Plr1165/50

Sodium Hypochlorite

0.2-40%

PL Chlorine HR 1 (30ml)

Plr1109

PL Chlorine HR 2 (30ml)

Plr1110

Sulphate

5-100 ppm

PL Sulphate Photometer Tablets (50pk)


PID055

Sulphate

Plr1160/50
5-100 ppm

PL Sulphate 1 (10g)
PID052

PID053

Plr1137

Sulphide

TBC

PL Sulphide No1 Photometer Tablets (50pk)

TBC

PL Sulphide No2 Photometer Tablets (50pk)

TBC

Sulphite LR

TBC

PL Sulphite LR Photometer Tablets (50pk)


PID086

PID105

PID082

Order Code

Sulphite HR

TBC
TBC

PL Sulphite HR 1 Photometer Tablets (50pk)

TBC

PL Sulphite HR 2 (65ml)

TBC

Sulphite HR

5-50 ppm

PL Sulphite HR 1 Photometer Tablets (50pk)

Plr1203/50

PL Sulphite HR 2 Photometer Tablets (50pk)

Plr1204/50

Suspended Solids

0-750 ppm

No Reagents Required
PID091

PID058

Tannic Acid

0-20 ppm

PL Tannin 1 (65ml)

Plr1176

PL Tannin 2 (30ml)

Plr1177

Triazole

TBC

PL Triazole 1 (50g)

TBC

UV lamp required
PID059

Turbidity

20-1000FAU

No Reagents Required

www.accepta.com

99

Section 14.2
PrimeLab Parameter & Reagents (continued)
ID

Parameter

Range

PID062

Zinc

0-1ppm

Order Code

PL Copper/Zinc LR Photometer Tablets (50pk)

Plr1161/50

PL EDTA Tablets (50pk)

Plr1190/50

Please Note:
New parameters are being added to the PrimeLab on a regular basis so it is important that you
update your PrimeLab to take full advantage of firmware and software upgrades.
If a parameter you require is not listed and you require multiple photometers, please email our
Technical Department (help@accepta.com) to enquire if the parameter can be added.

www.accepta.com

100

Section 15.0
Temperature Meters

www.accepta.com

101

Section 15.1
Temperature Meters - Pocket Stick Type
The Waterproof pocket Thermometer is pocket size with min/max
recording
Features

2.75 (70mm) Stainless steel stem.


C/F switchable ranges of 40 to 392F (-40 to
200C)
MAX/MIN recall of high and low temperatures
Hold and Auto Off Features
Digital display with 0.1 resolution
Dimensions: 150 x 20 x 18mm
Weight: 20g
Complete with one LR44 button battery and protective
cover
Ordering Code: 39240 (c/w - Certificate of Conformity)

www.accepta.com

102

Section 15.2
Temperature Meters - KT102 Dual K Type Thermometer
The Waterproof Type K Thermometer has a large LCD display with 0.3% accuracy.

Specifications:
Temperature (Type K:)
Display Counts:
Basic Accuracy:
Resolution:
Dimensions:
Weight:

Compact and rugged design features large


LCD display.
Selectable units of F and C
Wide temperature range with 0.1C or 1C
resolution
Data hold function freezes reading on display
Auto Power off to save battery life.
Low battery and over range indication
Records Max/Min readings for later recall
Complete with built-in stand, protective
holster, Type K bead wire temperature probe
(-4 to 482F/-20 to 250C).
Displays [T1 plus T2] or [T1-T2] or [T1-T2 plus
T2] and timer function displays elapsed time
plus the time when MIN and MAX readings
are taken.
Ordering Code: Eq5381P (c/w Certificate of
Conformity)

Item Code - Eq5381P:


--50 to 1300C
2000 count LCD
(0.3% + 2C)
0.1C or 1C
135 x 72 x 31mm
235g

Each ED381P comes complete with:


1 x Thermocouple bead type probe
1 x Penetration probe code (Code Eq5104S)
1 x Surface contact probe (Code Eq5103S)

www.accepta.com

103

Section 15.3
Temperature Meters - EA10 Dual K Type Thermometer
The Waterproof EA10 Type K Thermometer has a large LCD
display with 0.3% accuracy.

Specifications:
Temperature (Type K:)
Display Counts:
Basic Accuracy:
Resolution:
Dimensions:
Weight:
Power:

Compact and rugged design features large LCD


display.
Selectable units of F and C
Wide temperature range with 0.1C resolution
Data hold function freezes reading on display
Auto Power off to save battery life
Low battery and over range indication
Records Max/Min readings for later recall
Complete with built-in stand, protective holster,
Type K bead wire temperature probes (-4 to
482F/-20 to 250C).
Displays [T1 plus T2] or [T1-T2 plus T1] or [T1-T2
plus T2] and timer function displays elapsed time
plus the time when MIN and MAX readings are
taken
Ordering Code: EA10P (c/w Certificate of
Conformity)

Item Code - Eq5326P:


--50 to 1300C
2000 count LCD
(0.3% + 2C)
0.1C or 1C
152 x 72 x 37mm
235g
6 x AAA Batteries

Each EA10P Thermometer comes complete with:


1 x Thermocouple bead type probe
1 x Penetration probe code (Code Eq5104)
1 x Surface contact probe (Code Eq5103)

www.accepta.com

104

Section 15.4
Temperature Meters - Extech IR with K Type Input
Extech branded IR Thermometer with Type K input has
adjustable High/Low set points with visible and audible alarm and
0.1 resolution.
Features

Wide InfraRed temperature range: -58 to 1472F


(-50 to 800C)
13:1 distance to target ratio, laser pointer for easy
targeting
Type K input for surface temperature
measurements: -58 to 2498F (-50 to 1370C)
Automatic emissivity adjustment (for temperatures
212F or higher) 0.10 to 1.00 adjustable emissivity
increases measurement accuracy for different
surfaces
Adjustable high/low visual and audible alarm
Built-in memory with recall for 20 readings
MAX/MIN/AVG/DIF features display highest, lowest,
average and MAX minus MIN values.
C/w - 9v Battery, Type K bead wire probe & case
Ordering Code - 42515

Applications:

Measure surface temperature of objects difficult to reach or unsafe to contact.


Measure hot spots on motors, electrical panels, circuits, and other equipment
Used extensively in processes where glass, iron and steel, non-ferrous materials, and minerals
must be monitored.

Specifications
Range:
Basic Accuracy:

- 50 to 800C (infrared); -50 to 1370C (Type K)


InfraRed (2% rdg) or 4F/2C
Type K (1.5% rdg) or 2F/1C

www.accepta.com

105

Section 16.0
Equipment & Components

www.accepta.com

106

Section 16.1
Equipment & Components
Offering an extensive range of test equipment, parts and replacement components.
All products are available from stock for immediate dispatch.

Description:

Pack:

Code:

1ml Standard Syringe

Each

Eq5074

2ml Standard Syringe

Each

Eq5076

5ml Standard Syringe

Each

Eq5077

10ml Standard Syringe

Each

Eq5177

10ml Luer Lock Syringe

Each

Eq5073

20ml Standard Syringe

Each

Eq5168

20ml Luer Lock Syringe

Each

Eq5075

50ml Standard Syringe

Each

Eq5078

50ml Luer Lock Syringe

Each

Eq5078L

Brand DIGI Titrator Gun

Each

Eq5022

1.25ml Brand Syringe

Each

Eq5151

Brand DIGI Titrator Accessory Pack

Each

Eq5023

1ml Syringe [0-100] Titration by Syringe

Each

Eq5155

1ml Syringe Assembly Pack (Syringe, Valve & Titration Tube)

Each

Eq5190

Titration Tubes (Red Straw)

Each

Eq5118

3 Way Valve

Each

Eq5013

Syringes & Titration:

Filtration:
Syringe Filter Holder - 25mm

Eq5044

GF/C Filter Papers 25mm

50pk

Eq5048

Filter Papers 25mm 0.45 Micron

50pk

Eq5061

Filter Holder 13mm

Each

Eq5366

Filter Papers 13mm 8um

100pk

Eq5365

Filter Holder 47mm (Polypropylene)

Eq5086

0.45m Filter Papers 47mm

50pk

Eq5181

10ml Square Plastic Comparator Cells

5pk

Eq5006

5/10ml Tube with Screw Top

Each

Eq5015

10ml Plastic Tube (Scale 2-10ml) with push lid

Each

Eq5007

30ml Plastic Tube with Screw Top

Each

Eq5214

65ml Dropper Bottle, Cap & Tip

Each

Eq5019

50ml Glass Titration Jar

Each

Eq5016

65ml Plastic Test Bottle

Each

Eq5018

125ml Plastic Test Bottle

Each

Eq5008

Bottles & Tubes:

www.accepta.com

107

Description:

Pack:

Code:

250ml Plastic Test Bottle

Each

Eq5012

100ml Plastic Wide Neck Bottle

Each

Eq5002

250ml Plastic Wide Neck Bottle

Each

Eq5011

500ml Plastic Wide Neck Bottle

Each

Eq5083

1L Plastic Wide Neck Bottle

Each

Eq5033

250ml Rigid Wide Neck Bottle

Each

Eq5064

250ml Washer Bottle

Each

Eq5082

9v Battery

Each

Eq5131

AA Battery

Each

Eq5128

AAA Battery

Each

Eq5206

CR2032 Battery

Each

Eq5088

SR44 Battery

Each

Eq5158

Batteries:

Cases & Foams


2002 Micro Case

Eq5029

2002 Micro Case with 1 Foam

Eq5029F

2004 Mini Case with 1 Foam

Eq5030

2004 Mini Case with 2 Foams

Eq5030-2

2011 Medium Case with 1 Foam

Eq5028

2011 Medium Case with 2 Foams

Eq5028-2

2019 Maxi Case with 2 Foams

Eq5027

Mini Aluminium Case with Foams

Eq5026DF

Aluminium Engineers Case with Foams

Eq5026

Back Pack Case with Foams

Eq5026E

Accessories:
Plastic Comparator

Each

Eq5085

Tablet Crusher

Each

Eq5079

Cell Cleaning Brush

Each

Eq5196

Sulphate Turbidity Tube

Each

Eq5188

13 Plastic Turbidity Tube

Each

Eq5009

26 Plastic Turbidity Tube

Each

Eq5373

1.5ml Plastic Disposable Pipette

Each

Eq5222

Burette Complete Kit (Bottle, Jet, Pipette & Burette)

Eq5130

Burette 10ml Glass

Each

Eq5024

Burette Glass Jet Tip

Each

Eq5025

www.accepta.com

108

Section 17.0
Reagents Available

www.accepta.com

109

Section 17.1
Reagents Available
Offering an extensive range of reagents listed by Reagent Name.
All reagents are available from stock for immediate dispatch.

Description:

Pack:

Code:

20% Acetic Acid (65ml)

Each

Dt1103

A1 - Buffer (65ml)

Each

Dt1082

A2 - Precipitant (65ml)

Each

Dt1083

A3 - Solvent (50ml)

Each

Dt1087

A4 - Indicator (65ml)

Each

Dt1084

A5 - HR Titrant (65ml)

Each

Dt1085

A6 - LR Titrant (65ml)

Each

Dt1086

Acidifying PT Tablets (50Pk)

Each

Dt1414

Acidifying Solution (65ml)

Each

Dt1180

ALK1 - Phenolphthalein Indicator (65ml)

Each

Dt1008

ALK2 - Barium Chloride Solution 25% (65ml)

Each

Dt1188

ALK3 - HR Titrant (65ml)

Each

Dt1010

ALK4 - LR Titrant (65ml)

Each

Dt1011

Alka M Photometer Tablets (50Pk)

Each

Dt1342-50

Alkalinity M (Total) Tablets [Tablet Count] (250B)

Each

Dt1478

Alkalinity Neutralising Solution (65ml)

Each

Dt1102

Alkalinity P Photometer Tablets (50Pk)

Each

Dt1538-50

Alkalinity P Tablets [Tablet Count] (250B)

Each

Dt1535

Aluminium No1 Tablets (50Pk)

Each

Dt1147-50

Aluminium No2 Tablets (50Pk)

Each

Dt1148-50

Amine Buffer Solution (65ml)

Each

Dt1644-65

Amine Indicator Solution (65ml)

Each

Dt1643-65

Amine Solvent (50ml)

Each

Dt1645-50

Amine Test Tablets (50Pk)

Each

Dt1042

Ammonia No1 Tablets (50Pk)

Each

Dt1245-50

Ammonia No2 Tablets (50Pk)

Each

Dt1244-50

Ammonium Vanadomolybdate Solution (65ml)

Each

Dt1219

Ascorbic Acid (10g)

Each

Dt1237

BC1/CC1 - Chloride Indicator (65ml)

Each

Dt1023

BC2 - Chloride HR Titrant (65ml)

Each

Dt1026

BP1V (65ml)

Each

Dt1479

Calcium Hardness Tablets [Tablet Count] (250B)

Each

Dt1494

www.accepta.com

110

Section 17.1
Reagents Available (continued)
Carbohydrazide LR Indicator Solution (65ml)

Each

Dt1741

Carbohydrazide LR Test Solution (65ml)

Each

Dt1654

Carbohydrazide Reagent (65ml)

Each

Dt1259

CC2 - Chloride LR Titrant (65ml)

Each

Dt1024

CD01 - Chlorine Dioxide Buffer (65ml)

Each

Dt1036

CD02 - LR Titrant (65ml)

Each

Dt1037-65

CD02A - VLR Chlorine Dioxide Titrant (65ml)

Each

Dt1122

CD03 - High Range Titrant (65ml)

Each

Dt1038

CD1 - Indicator (65ml)

Each

Dt1009

CH1P - Calcium Hardness Indicator Powder (20g)

Each

Dt1050

CH1T - Calcium Hardness Indicator Tablets (50Pk)

Each

Dt1105

CH2 - Calcium Hardness Buffer (65ml)

Each

Dt1043

Chloride No1 Tablets (50Pk)

Each

Dt1591-50

Chloride No2 Tablets (50Pk)

Each

Dt1592-50

Chloride Tablets [Tablet Count] (50Pk)

Each

Dt1510-50

Chlorine HR Powder (20g)

Each

Dt1345

Chlorine HR Reagent (65ml)

Each

Dt1179

Chlorine HR Tablets (50Pk)

Each

Dt1221-50

Chlorocol Tablets (100Pk)

Each

Dt1141

Chloroform Solvent (50ml)

Each

Dt1142

Cleaning Acid Strength Tablets (100B)

Each

Dt1025

Copper HR Powder (20g)

Each

Dt1738-20

Copper No1 Tablets (50Pk)

Each

Dt1240-50

Copper No2 Tablets (50Pk)

Each

Dt1239-50

Copper Reagent 1 (65ml)

Each

Dt1211

Copper Reagent 1 (65ml)

Each

Dt1211

Copper Reagent 2 (10g)

Each

Dt1212

Copper/Zinc HR Tablets (50Pk)

Each

Dt1203-50

Copper/Zinc LR Tablets (50Pk)

Each

Dt1149-50

Coppercol Reagent 1 (30ml)

Each

Dt1169

Coppercol Reagent 2 (30ml)

Each

Dt1170

Coppercol Reagent 3 (10g)

Each

Dt1231

CRP Reagent (65ml)

Each

Dt1236

Cyanuric Acid Test Tablets (50Pk)

Each

Dt1391-50

DBN4 pH Adjuster (65ml)

Each

Dt1391-52

Dechlor Tablets (50Pk)

Each

Dt1391-53

DEHA Indicator Solution (65ml)

Each

Dt1391-54

DEHA Test Solution (65ml)

Each

Dt1391-55

DEHA Test Tablets (50Pk)

Each

Dt1246

www.accepta.com

111

Section 17.1
Reagents Available (continued)
dK1 (30ml)

Each

Dt1254

dK2 (65ml)

Each

Dt1255

dK3 (65ml)

Each

Dt1256

dK4 (65ml)

Each

Dt1257

dK5 (30ml)

Each

Dt1258

DPD Acidifying Solution (65ml)

Each

Dt1671

DPD Acidifying Test Tablets (50Pk)

Each

Dt1443-50

DPD Free Chlorine Pillows, 10ml Sample (100Pk)

Each

Dt1275

DPD Glycine Powder (20g)

Each

Dt1143

DPD Glycine Solution (30ml)

Each

Dt1525-30

DPD Glycine Tablets (50Pk)

Each

Dt1146-50

DPD Neutralising Tablets (50Pk)

Each

Dt1392-50

DPD Nitrite Tablets (50Pk)

Each

Dt1131-50

DPD No 1 Branded Tablets (50Pk)

Each

Dt1106-50

DPD No 3 Branded Tablets (50Pk)

Each

Dt1107-50

DPD No1 Rapid Dissolving Tablets (50Pk)

Each

Dt1533-50

DPD No1 Solution A (30ml)

Each

Dt1505-30

DPD No1 Solution B (30ml)

Each

Dt1506-30

DPD No3 Solution C (30ml)

Each

Dt1507-30

DPD Total Chlorine Pillows, 10ml Sample (100Pk)

Each

Dt1277

DSP Solution (65ml)

Each

Dt1204

EDTA Tablets (50Pk)

Each

Dt1205-50

EX1 (65ml)

Each

Dt1137

EX2 (65ml)

Each

Dt1135

EX3 (65ml)

Each

Dt1136

EX4 (65ml)

Each

Dt1134-65

EX5 (65ml)

Each

Dt1138

EX6 (65ml)

Each

Dt1139

Fast Chlor Tablets [1L/3000ppm] (200Pk)

Each

Dt1252

FCL1 - Buffer (65ml)

Each

Dt1027

FCL2 - LR Titrant (65ml)

Each

Dt1028

FCL3 - HR Titrant (65ml)

Each

Dt1029

FE10 - Iron HR Comparator Solution [0-10ppm] (65ml)

Each

Dt1247

Fe5 - Iron LR Reagent (65ml)

Each

Dt1110

FE6 - Iron HR Reagent (65ml)

Each

Dt1113

FE8 - Iron HR Reagent (65ml)

Each

Dt1128

FE9 - Iron MR Reagent (65ml)

Each

Dt1723

FIR1 (65ml)

Each

Dt1340

FIR2 (65ml)

Each

Dt1341

FIR3 (65ml)

Each

Dt1445-65

www.accepta.com

112

Section 17.1
Reagents Available (continued)
GL1 (5g)

Each

Dt1605

GL2 - Titrant (65ml)

Each

Dt1606

GL3 - Titrant (65ml)

Each

Dt1607

H/TH4/CH3 - HR Titrant (65ml)

Each

Dt1049

Hardness HR Reagent (65ml)

Each

Dt1477

Hardness LR Reagent (65ml)

Each

Dt1476

Hardness MR Reagent (65ml)

Each

Dt1475

Hardness Stop/Go Solution (65ml)

Each

Dt1129

Hardness Total Tablets [Tablet Count] (50Pk)

Each

Dt1530-50

Hardness Yes/No Tablets (50Pk)

Each

Dt1121-50

HFE1 - Buffer (65ml)

Each

Dt1055

HFE2 - Indicator (65ml)

Each

Dt1056

HFE3 - Indicator (20g)

Each

Dt1057

HFE4 - Titrant (65ml)

Each

Dt1058

HP1 - Buffer (65ml)

Each

Dt1051

HP2 - HR Titrant (65ml)

Each

Dt1052

HP3 - LR Titrant (65ml)

Each

Dt1053

Hydrazine Concentrate Reagent (65ml)

Each

Dt1468

Hydrogen Peroxide HR Tablets (50Pk)

Each

Dt1413

Iron HR Tablets (50Pk)

Each

Dt1230-50

Iron LR Tablets (50Pk)

Each

Dt1117-50

M1 - Molybdate Buffer (65ml)

Each

Dt1355

M2 - Indicator (65ml)

Each

Dt1356

M3 - LR Titrant (65ml)

Each

Dt1357

Manganese LR No1 Tablets (50Pk)

Each

Dt1349-50

Manganese LR No2 Tablets (50Pk)

Each

Dt1350-50

Manganese Reagent 1 (30ml)

Each

Dt1771

Manganese Reagent 2 (30ml)

Each

Dt1772

Manganese Reagent 3 (30ml)

Each

Dt1773

MB1 - Molybdate LR Buffer (65ml)

Each

Dt1063

MB2 - Molybdate LR (5g)

Each

Dt1064

MB3 - Titrant (65ml)

Each

Dt1065

MLB1 - Molybdate Indicator/Buffer [0-500ppm] (65ml)

Each

Dt1440

MLB2 - Molybdate Titrant [0-500ppm] (65ml)

Each

Dt1441

MLB3 - Molybdate Reagent [0-500ppm] (65ml)

Each

Dt1550

www.accepta.com

113

Section 17.1
Reagents Available (continued)
MO1 - Acidifier (65ml)

Each

Dt1066

MO2 - Buffer (20g)

Each

Dt1067-20

MO2 - Buffer (40g)

Each

Dt1067

MO3 - Indicator (65ml)

Each

Dt1068

MO4 - LR Titrant (65ml)

Each

Dt1069

MO5 - Masking Reagent (65ml)

Each

Dt1070

MO6 - HR Titrant (65ml)

Each

Dt1071

Molybdate HR Powder 1 (20g)

Each

Dt1732-20

Molybdate HR Powder 2 (20g)

Each

Dt1733-20

Molybdate HR Powder 3 (20g)

Each

Dt1734-20

Molybdate HR Reagent (65ml)

Each

Dt1127

Molybdate No1 Tablets (50Pk)

Each

Dt1115-50

Molybdate No2 Tablets (50Pk)

Each

Dt1116-50

N1 - Nitrite Indicator [10 - 2,000ppm] (65ml)

Each

Dt1072

N1HR - Nitrite HR Buffer (65ml)

Each

Dt1177

N2 - Nitrite Titrant [10 - 2,000ppm] (65ml)

Each

Dt1073

N2HR - Nitrite HR Titrant (65ml)

Each

Dt1178

Nitrate HR Powder (40g) [For use with Comparator]

Each

Dt1748

Nitrite No1 Tablets (50Pk)

Each

Dt1373-50

Nitrite No1 Tablets [Tablet Count] (250B)

Each

Dt1536

Nitrite No2 Tablets [Tablet Count] (250B)

Each

Dt1537

Organo-Phosphonate No1 Tablets (50Pk)

Each

Dt1151-50

P1 - CL Remover (65ml)

Each

Dt1078

P1/2 - Phosphonate Neutraliser/Indicator (65ml)

Each

Dt1514-65

P1/4 - Indicator Tablets (50Pk)

Each

Dt1074

P1/4L - Phosphonate Indicator (65ml)

Each

Dt1260

P1/M - Solvent (50ml)

Each

Dt1012

P2 - Indicator (65ml)

Each

Dt1079

P3 - pH Adjuster (65ml)

Each

Dt1080

P4 - Phosphonate Indicator Tablets (50Pk)

Each

Dt1081-50

P4/2 - Titrant (65ml)

Each

Dt1088

P5 - Titrant (65ml)

Each

Dt1075

PA1 - Phenolphthalein Indicator (65ml)

Each

Dt1001

PA2/TA2 - HR Alkalinity Titrant (65ml)

Each

Dt1005

PA3 - Alkalinity OH Reagent (65ml)

Each

Dt1007

www.accepta.com

114

Section 17.1
Reagents Available (continued)
PB1 - Phosphate HR No 1 (65ml)

Each

Dt1111

PB2 - Phosphate HR No 2 (65ml)

Each

Dt1112

pH10 Buffer Solution (65ml)

Each

Dt1161-65

pH4 Buffer Solution (65ml)

Each

Dt1119-65

pH7 Buffer Solution (65ml)

Each

Dt1118-65

Phenol Red Branded Tablets (50Pk)

Each

Dt1220-50

Phenol Red Rapid Dissolving Tablets (50Pk)

Each

Dt1243-50

Phenol Red Solution (65ml)

Each

Dt1250

PHMB Tablets [Rapid Dissolving] (50Pk)

Each

Dt1616-50

Phosphate HR P1 Tablets (50Pk)

Each

Dt1521-50

Phosphate HR P2 Tablets (50Pk)

Each

Dt1522-50

Phosphate HR Tablets [0-80ppm] (50Pk)

Each

Dt1163-50

Phosphate LR No1 Tablets (50Pk)

Each

Dt1225

Phosphate LR No2 Tablets (50Pk)

Each

Dt1226

Phosphate LR Powder (20g)

Each

Dt1731-20

PO1 - Buffer (65ml)

Each

Dt1351

PO2 - Indicator (65ml)

Each

Dt1352

PO3 - Titrant (65ml)

Each

Dt1353

Potassium Iodide Tablets 0.1g (50Pk)

Each

Dt1546-50

Probe Cleaning Solution (65ml)

Each

Dt1469-65

Probe Rinsing Solution (65ml)

Each

Dt1470

Probe Storing Solution (65ml)

Each

Dt1471

QA1 - Indicator (65ml)

Each

Dt1089

QA2 - Acidifier (65ml)

Each

Dt1090

QA3 - Titrant (65ml)

Each

Dt1091

QA4 (65ml)

Each

Dt1157

QA5 - Titrant (65ml)

Each

Dt1158

RA1 - Resin Iron Reagent (65ml)

Each

Dt1338

RA2 - Resin Iron Reagent (65ml)

Each

Dt1336

RA3 - Resin Organic Reagent (65ml)

Each

Dt1339

Redox Probe Cleaner (65ml)

Each

Dt1222

Redox Standard 200mV (65ml)

Each

Dt1238-65

Redox Standard 250mV (65ml)

Each

Dt1347-65

Redox Standard 300mV (65ml)

Each

Dt1580

Redox Standard 465mV (65ml)

Each

Dt1448-65

www.accepta.com

115

Section 17.1
Reagents Available (continued)
Redox Standard 475mV (65ml)

Each

Dt1223-65

Redox Standard 650mV (65ml)

Each

Dt1420-65

S1 - Sulphite Indicator Powder (40g)

Each

Dt1092

S2 - Sulphite Titrant (65ml)

Each

Dt1093

Silica HR Powder 1 (20g)

Each

Dt1735-20

Silica HR Powder 2 (60g)

Each

Dt1736-60

Silica HR Powder 3 (10g)

Each

Dt1737-10

Silica No1 Tablets (50Pk)

Each

Dt1195

Silica No2 Tablets (50Pk)

Each

Dt1201

Silica PR Tablets (50Pk)

Each

Dt1156

Silica Reagent 1 (65ml)

Each

Dt1233

Silica Reagent 2 (65ml)

Each

Dt1234

Silica Reagent 3 (20g)

Each

Dt1235

SO1 - Sulphite Buffer (65ml)

Each

Dt1540

SO2 - Sulphite Titrant (65ml)

Each

Dt1541

Standard Conductivity Solution 100uS (65ml)

Each

Dt1217-65

Standard Conductivity Solution 10uS (65ml)

Each

Dt1419-65

Standard Conductivity Solution 12.88mS (65ml)

Each

Dt1154-65

Standard Conductivity Solution 1413 (65ml)

Each

Dt1109-65

Standard Conductivity Solution 2000uS (65ml)

Each

Dt1209-65

Standard Conductivity Solution 3500uS (65ml)

Each

Dt1458-65

Standard Conductivity Solution 5000uS (65ml)

Each

Dt1153-65

Standard Conductivity Solution 500uS (65ml)

Each

Dt1120-65

Standard Conductivity Solution 50uS (65ml)

Each

Dt1398

Standard Conductivity Solution 6440uS (65ml)

Each

Dt1218-65

Standard Conductivity Solution 84uS (65ml)

Each

Dt1232-65

Sulphate Buffer (65ml)

Each

Dt1227

Sulphate Conditioner (65ml)

Each

Dt1228

Sulphate No.2 Tablets (250Pk)

Each

Dt1613

Sulphate No1 Tablets (250Pk)

Each

Dt1612

Sulphate Precipitant (20g)

Each

Dt1229

Sulphate Turbidity Powder (20g)

Each

Dt1729

Sulphuric Acid 50% (65ml)

Each

Dt1155

TA3 - LR Alkalinity Titrant (65ml)

Each

Dt1006

TA4 - pH4.5 Indicator (65ml)

Each

Dt1004

www.accepta.com

116

Section 17.1
Reagents Available (continued)
Tannin No1 T/C Tablets (100B)

Each

Dt1159-100B

Tannin No2 T/C Tablets (250B)

Each

Dt1160-250B

TBR1 - Buffer (65ml)

Each

Dt1016

TBR2 - Titrant (65ml)

Each

Dt1017

TH1P - Total Hardness Indicator Powder (20g)

Each

Dt1048

TH1T - Total Hardness Indicator Tablets (50pk)

Each

Dt1104

TH2 - Total Hardness Buffer (65ml)

Each

Dt1046

TH3 - LR Titrant (65ml)

Each

Dt1044

TH5 - Total Hardness Indicator (65ml)

Each

Dt1047

THPS Starch Indicator (10g)

Each

Dt1207

TN1 - Tannin Buffer (40g)

Each

Dt1094

TN2 - Tannin Titrant (65ml)

Each

Dt1095

TO1 (65ml)

Each

Dt1213

TO2 (40g)

Each

Dt1214

TO3 (40g)

Each

Dt1215

TO4 (65ml)

Each

Dt1216

Total Hardness Photometer Tablets (50Pk)

Each

Dt1593-50

Universal pH Indicator (65ml)

Each

Dt1164

Universal pH Tablets (100Pk)

Each

Dt1710-100

Z1 - CL Remover (65ml)

Each

Dt1096

Z2 - Buffer (65ml)

Each

Dt1099

Z4/P - Indicator Powder (20g)

Each

Dt1098

Z4/T - Indicator Tablets (50Pk)

Each

Dt1101

Z4/T - Indicator Tablets (50Pk)

Each

Dt1101

Zinc Reagent 1 (65ml)

Each

Dt1167

Zinc Reagent 2 (20g)

Each

Dt1168

www.accepta.com

117

Standard Terms & Conditions of Sale


1. Definitions
In these terms and conditions, the following words shall have the
following meanings:the company shall mean Accepta Ltd.
the Goods shall mean the products or articles which are
manufactured or sold by the company.
the Buyer shall mean the purchaser of the goods from the
Company.

2. The Contract
2.1 All orders are accepted under these Terms & Conditions
alone.
2.2 These Terms & Conditions exclude any other Terms &
Conditions inconsistent therewith which a buyer might seek to
impose even though such other terms and conditions may be
submitted in a later document and/or purport to exclude or
supersede any Terms & Conditions inconsistent with them or
may be contained in any offer acceptance or counter-offer made
by the Buyer.
2.3 No variations of these Terms & Conditions is permitted
unless expressly accepted by a Director of the Company in
writing.
2.4 All verbal orders must be confirmed to the Company in
writing by email, fax or by post.

3. Cancellation
3.1 No cancellation by the Buyer is permitted except where
expressly agreed by the Company.
3.2 The Buyer will in the event of agreed cancellation by the
Buyer indemnify the Company fully against all expenses incurred
up to the time of such cancellation.

4. Price
4.1 All prices charged are those ruling at the date of acceptance
of the order from the Buyer unless otherwise stated.
4.2 Unless otherwise stated the prices charged are net ex works
exclusive of Value Added Tax.
4.3 The Company reserves the right at any time prior to delivery
of the Goods to adjust the price to take account of any increase
in the cost of raw materials, labour or services, taxes or duties or
any currency fluctuations affecting the cost of imported materials.

5. Terms of Payment
5.1 The Buyer shall make payment net cash with the Buyers
order except where the Company has agreed to open a credit
account. In the case, the Buyer shall make payment net cash
against every invoice from the Company within 30 days of the
date of such invoice.
5.2 Time for payment shall be of the essence.
5.3 The Company reserves the right to charge interest at 2% per
month on all overdue accounts., such interest being deemed to
accrue on a day to day basis from the due date for payment
under clause 5.1.
5.4 The Buyer shall have no right of set off, statutory or otherwise.
5.5 If the Buyer (being a company) has a petition presented for
its winding-up or for an administration order under the Insolvency
Act 1986 or passes a resolution for voluntary winding-up otherwise than for the purpose of a bona fide amalgamation or
reconstruction or compounds with its creditors or has a receiver
appointed of all or any part of its assets or (being an individual)
becomes bankrupt of insolvent or enters into any arrangement
with its creditors of commits a material or serious breach of this
Agreement (and in the case of such a breach being remediable
fails to remedy it within 7 days of receiving notice to do so), he
will be deemed to have repudiated the Contract.
5.6 The Company reserves the right at any time at its discretion
to demand security for payment before continuing with or
delivering any Order.

6. Delivery
6.1 All items quoted for delivery shall be delivered to the Buyers
address or, if different, as specified on the Buyers order.
6.2 The Company shall be responsible for the delivery of Goods
to the delivery address, but the cost of such delivery, packing
and insurance may be charge to the Buyer.
6.3 Time of delivery is not of the essence.
6.4 The Company shall not be liable for any loss whatsoever or
howsoever arising caused by its non-delivery.
6.5 The Company reserves the right to make delivery by instalments and to tender a separate invoice in respect of each
instalment.
6.6 When delivery is to be by instalment or the Company exercises its right to delivery by instalments under clauses 6.5 hereof or
if there be any delay in the delivery of any one or more instalments for whatever reason this will not entitle the Buyer to treat
the contract as repudiated or to damages.
6.7 Deviations in quantity of the Goods delivered (representing
not more than 10 per cent by value) from that stated in the
Buyers ordeal shall not give the Buyer any right to reject the
Goods or to claim damages and the Buyer shall be obliged to
accept and pay at the contract rate for the quantity of the Goods
delivered.

7. Risk and the Passing of Property


7.1 Risk in the Goods shall be pass the Buyer when the Goods
are delivered to, or collected by, the Buyer or his agent.
7.2 Notwithstanding risk in the goods passing in accordance with
clause 7.1 hereof, title in the goods shall not pass to the Buyer
until payment has been received by the Company for the Goods
and no other amounts are then outstanding from the Buyer to the
Company in respect of other Goods supplied by the Company.
7.3 The Buyer is licensed by the Company to use or agree to sell
the Goods delivered to the Buyer subject to the provisions of
clauses 7.4 and 7.5.
7.4 Until title to the Goods passes:7.4.1 the Buyer will hold the Goods as fiduciary agent and
bailee for the Company;
7.4.2 the Goods shall be kept separate and distinct from all
other property of the Buyer and of third parties and in good and
substantial repair and condition and be stored in such a way as
to be clearly identifiable as belonging to the Company;

7.4.3 the Company may at any time revoke the power of sale
and use of the Goods by notice to the Buyer if the Buyer is in
default for longer than 14 days in the payment of any sum
whatsoever due to the Company (whether in respect of the
Goods or any other goods supplied at any time by it to the Buyer)
or if the Company has bona fide doubts as to the solvency of the
Buyer);
7.4.4 the Buyers power of sale and use shall automatically
cease if the Buyer has a petition presented for its winding-up or
for an administration order under the Insolvency Act 1986 or
passes a resolution for voluntary winding-up otherwise than for
the purposes of a bona fide amalgamation or reconstruction or
compounds with its creditors or has a receiver appointed of all or
any part of its assets or becomes bankrupt or insolvent or enters
into any arrangements with creditors or takes or suffers any
similar action in consequence of debts or carries out or undergoes any analogous act or proceedings under foreign law;
7.4.5 upon determination of the Buyers power of sale and use
the Buyer shall place any of the Goods, in its possession or under
its control, at the disposal of the Company and the Company shall
be entitled to enter the premises of the Buyer for the purpose of
removing the Goods.
7.5 The Company shall at any time be entitled to appropriate any
payment made by the Buyer in respect of any Goods in settlement of such invoices or accounts in respect of such goods as
the Company may in its absolute discretion think fit notwithstanding any purported appropriated to the contrary by the Buyer.

8. Lien and Stoppage


Until such time as the title in the Goods has passed to the Buyer
the Company has the right to withhold delivery if the Buyer (being
a Company) has a petition presented for its winding-up or for an
administration order under the Insolvency Act 1986 or passes a
resolution for voluntary winding-up otherwise than for the purpose
of a bona fide amalgamation or reconstruction or compounds with
its creditors or has a receiver appointed of all or part of its assets
or (being an individual) becomes bankrupt or insolvent or enters
into any arrangements with creditors or takes or suffers any
similar action in consequence of debts or carries out or undergoes any analogous act or proceedings under the foreign law.

9. Inspection/Shortage
9.1 The Buyer is under a duty whenever possible to inspect the
Goods on delivery or on collection as the case may be.
9.2 Where the Goods cannot be examined the carriers note or
such other note as appropriate shall be marked not examined.
9.3 The Company shall be under no liability for any damage or
shortages that would be apparent on careful inspection if the
terms of this clause are not complied with and, in any event will
be under no liability if a written complaint is not delivered to the
Company within 10 days of delivery detailing the alleged damage
or shortage.
9.4 In all cases where defects or shortages are complained of the
Company shall be under no liability in respect thereof unless an
opportunity to inspect the Goods is supplied to the Company
before any use is made thereof or any alteration or modification is
made thereto by the Buyer.
9.5 Subject to Clause 9.3 and 9.4, the Company shall make good
and shortage in the Goods and where appropriate replace any
goods damaged in transit as soon as it is reasonable to do so, but
otherwise shall be under no liability whatsoever arising from such
shortage or damage.

10. Warranty
10.1 The Company warrants that it has title to and the unencumbered right to sell the Goods.
10.2 It is the Buyers responsibility to ensure that the Goods are
suitable for the purpose to which that are intended to be used.
10.3 No representation or warranty is given as to the suitability or
fitness of the Goods for any particular purpose and the Buyer
shall satisfy itself in this respect and shall be totally responsible
thereof.
10.4 If the Buyer has any specific requirements for the use of the
Goods the Buyer must notify requirements to the Company in
writing before purchasing the Goods.
10.5 If the Buyer is unsure as to the suitability of any Goods for a
particular purpose it should consult the Company prior to purchase.
10.6 If the Goods are in such a state as would but for this
condition entitle the Buyer to repudiate the contract and/or claim
damages from the Company, the Company reserves the right to
repair or replace the Goods.

7 working days of discovering it;


And
(2) he returns the Goods to the Company at his own expense.
11.2.5 The risk of accidental loss whilst the Goods are being
returned will be borne by the Buyer.
11.2.6 In consideration for receiving the benefit of this clause,
the Buyer agrees that, apart from those terms set out in Clauses
9 and 10, no other terms, conditions, warranties or in nominate
terms, express or implied, statutory or otherwise, shall form part
of this contract.
11.3 Exclusion of Consequential Loss
The Company shall not be liable for any consequential or indirect
loss suffered by the Buyer whether their loss arises from breach
of duty in contract or tort or in any other way (including loss
arising from the Companys negligence). Non exhaustive illustrations of consequential or indirect loss would be:
- Loss of profits
- Loss of contracts
- Damage to property of the Buyer or anyone else, and personal
injury to the Buyer or anyone else (except so far as such injury is
attributable to the Companys negligence).
11.4 Limitation
The Companys total liability for any one claim or for the total of
all claims arising from any one act or default of the Company
(whether arising from the Companys negligence or otherwise)
shall not exceed 100,000.

12. Special Packaging or Materials


Where special materials or branded packaging are required to
satisfy the Buyers order specification, it will be a condition that
nay surplus quantity of these items produced by the Company
will, on completion of the Buyers order, be invoiced to, and
payable by, the Buyer.

13. Force Majeure


13.1 The Company shall not be liable for any failure to deliver the
Goods arising from circumstances outside the Companys control.
13.2 Non-exhaustive illustrations of such circumstances would be
act of God, war, riot, explosion, abnormal weather conditions, fire,
flood, strikes, lockouts, Government action or regulations (UK or
otherwise), delay by suppliers, accidents and shortage of materials, labour or manufacturing facilities.
13.3 Should the Company be prevented from delivering ion the
above circumstances, it shall give the Buyer written notice of this
fact as soon as reasonably practicable.
13.4 If the circumstances preventing delivery are still continuing
three months after the Buyer receives the Companys notice, then
either party may give written notice to the other cancelling the
contract.
13.5 If the contract is cancelled in this way, the Company will
refund any payment which the Buyer has already made on
account of the price (subject to deduction of any amount the
Company is entitled from the Buyer) but the Company will not be
liable to compensate the Buyer for any further loss or damage
caused by the failure to deliver.

14. Sales Promotion Documentation


14.1 Whilst the Company takes every precaution in the preparation of its catalogues, technical circulars, price lists and its
literature, these documents are for the Buyers general guidance
only and the particulars contained therein shall not constitute
representations by the Company and the Company shall not be
bound thereby.
14.2 Illustrations and sizes refer to patterns as made at the time
of publication. In view of continued improvements and variations
in availability of materials, the right is reserved to supply Goods of
similar quality which may not correspond exactly with the particulars given.

15. Notice
Any notice to be given hereunder shall be in writing and shall be
deemed to have been duly given if sent or delivered to the party
concerned at its address specified overleaf or such address as
the party may from time to time notify in writing and shall be
deemed to have been served, if sent by post, 48 hours after
posting.

16. Assignment
Neither the Company nor the Buyer shall assign or transfer or
purport to assign of transfer the contract or the benefits thereof to
any other person without prior written consent of the other.

11. Liability

17. Proper Law and Jurisdiction

11.1 Introduction
11.1.1 Nothing in clause 11 shall be deemed to exclude or
restrict the Companys liability for death or personal injury
resulting from the Companys negligence.
11.1..2 Each of the sub-clauses in Clause 11 is to be treated
as separate and independent.
11.2 Exclusion
11.2.1 Clauses 11.2 only covers defects caused by faulty
design, manufacture, materials or workmanship. It does not cover
defects caused by abnormal use, misuse or neglect. It does not
cover faulty design, manufacture materials or workmanship
supplied or undertaken by the Buyer or third parties. In respect of
goods not designed or manufactured by the Company, the
Company only gives such guarantee or warranty to the Buyer as
the Company itself receives.
11.2.2 The Company agrees that if any defect covered by
Clause 11.2 is discovered during the period of twelve months
commencing with the date of dispatch, the Company will either
repair the goods at its own expense or, if it chooses to do so,
replace them.
11.2.3 The Company does not bear responsibility for any
defect arising or introduced by a Buyer in the course of storage or
handling of the products where that Buyer acts as an agent or
distributor of the Companys products. The Buyer should consult
the Company if doubt exists with regard to the appropriate
storage or handling requirements.
11.2.4 The Buyer cannot claim the benefit of this clause
unless:
(1) he informs the Company of the relevant defect in writing within

The contract shall be governed by and construed in accordance


with the law of England.

www.accepta.com

18. Waiver
The rights and remedies of the Company under the contract shall
not be diminished, waived or extinguished by the granting of any
indulgence, forbearance or extension of time by the Company in
asserting or exercising any such rights or remedies.

19. Headings
The headings of these conditions are for convenience only and
shall have no effect on the interpretation thereof.

118

www.accepta.com

119