Section 2.0
2.1 Company Information
Accepta
Statham House
Talbot Road
Manchester M32 0FP
United Kingdom
Tel :
Fax :
Email :
orders@accepta.com
Phone: +44 (0) 161 877 2334 (e-mail confirmation is required on all telephone orders)
Fax:
General
1) Prices, where quoted are exclusive of VAT and delivery.
2) For Terms & Conditions of Sale, please refer to our website www.accepta.com/terms-conditions
3) Orders received will generally be dispatched within 2 working days.
4) A standard delivery charge will apply on all orders.
5) The delivery charge for dip slides and/or large test kits and reagent orders will be dependant on
the weight of the goods, please ask for a quote for delivery charges.
6) The shelf life of most reagents is greater than 2 years when stored in correct conditions. Please
refer to the relevant reagent Safety Data Sheet (SDS) for full details.
7) All reagents and kits can be branded with your own logo, please contact us for details.
8) Product SDS sheets are available own branded and in many languages, please ask for details.
9) All electronic equipment is warranted for 12 months from date of dispatch.
10) Probes for pH, Conductivity and other meters are warranted for 6 months from date of dispatch.
11) Returns must be notified in writing within 48 hours of receipt of goods.
12) All payments are due within 30 days from date of invoice.
13) If an invoice remains unpaid after our agreed payment terms, we reserve the right to forward the
invoice to a debt collection agency which will incur an additional 20% surcharge.
14) Some images of test kits and components shown in the catalogue may differ from the actual
goods supplied due to stock availability.
www.accepta.com
Section 3.0
Test Method Selector
This useful selector can be used to help identify the test methods we have available for those
parameters you wish to monitor. Simply select the parameter from the left column, then work across
to identify which test methods are available. If you need help identifying the most appropriate test
method for your application please contact Acceptas technical team.
Parameter
PrimeLab
Drop Test
Test
Meters
Acidity
Active Oxygen
Alkalinity
Aluminium
Amine
Ammonia
Anionic
Boron
Bromine
Carbohydrazide
Chelant
Chloride
Chloramines
Chlorine (TS)
Chlorite
Chromium
Colour
Conductivity/TDS
Copper (TS)
Cyanuric Acid
DEHA
DBNPA
Fluoride
Glutaraldehyde
Biocide Kit
Biocide Kit
Hardness, Stop/Go
Hardness, Total (TS)
Glycol (PEG/MEG)
Hardness, Calcium
www.accepta.com
Section 3.0
Test Method Selector (continued)
Parameter
PrimeLab
Hydrazine
Hydroquinone
Hydrogen Peroxide
(TS)
Iodine
Iron (TS)
Drop Test
Isothiazalone
Biocide Kit
Magnesium
Manganese (TS)
Molybdate
Nickel
Nitrate
Nitrite
Ozone
Phenol
PHMB
Phosphate
Phosphonate
Polyacrylate
Polyamine
Polymers
Potassium (TS)
QAC
Silver
Sodium
Hypochlorite
Sulphate
Sulphide
Sulphite
Suspended Solids
Silica
Tannin
www.accepta.com
Section 3.0
Test Method Selector (continued)
Parameter
PrimeLab
THPS
Drop Test
Biocide Kit
Total Oxidant
Triazole
Turbidity
Zinc
Note: Parameters above with a (TS) denotes where Test Strips are available as an alternative testing
method.
IF THE PARAMETER YOU ARE INTERESTED IN IS NOT LISTED, PLEASE CONTACT US
www.accepta.com
Section 4.0
Test Kits
www.accepta.com
Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P
Acceptas Eng3005P comprehensive combined test kit is based on
photometer and titration gun chemistries and has been developed
as a complete kit, specifically for water treatment professionals
involved with the maintenance and management of boiler, cooling
water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all
the equipment and reagents necessary to effectively test and monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are achieved and maintained.
This test kit includes the following:
Contents
Range
Code
Eq5026
Waterproof Instructions
Eq5084
Eq5075
Eq5073
Eq5077
Eq5074
Eq5044
Eq5048
Eq5061
Eq5008
Eq5018
1 x 5/10ml Tube
Eq5015
Eq5082
Eq5119
PrimeLab Photometer
Plp1001
Pla1100
Alkalinity P (Titration)
0 - 2000
PA1 (65ml)
Dt1001
Crt91002
Alkalinity M (Titration)
0 - 2000
TA4 (65ml)
Dt1004
Alkalinity OH (Titration)
0 - 2000
PA3 (65ml)
Dt1007
www.accepta.com
Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P (continued)
Contents
Range
Bromine (PrimeLab)
0.05 - 18
Code
PL DPD 1 A (30ml)
Plr1102
PL DPD 1 B (30ml)
Plr1103
Plr1104
Chloride (Titration)
0 - 2000
BC1/CC1 (65ml)
Dt1023
Crt91003
Chlorine (PrimeLab)
0.01 - 8
Plr1104
0.02 - 15
Plr1106
0 - 2000
TH2 (65ml)
Dt1046
TH5 (65ml)
Dt1047
Crt91007
0 - 2000
CH2 (65ml)
Dt1043
CH1P (20g)
Dt1050
0-4
Dt1129
0 - 30
PL Iron HR 1 (65ml)
Plr1119
PL Iron HR 2 (30ml)
Plr1120
Molybdate HR (PrimeLab)
PL Molybdate 1 (65ml)
Plr1139
Nitrite (PrimeLab)
0 - 3000
PL Nitrite HR 2 (65ml)
Dt1072
Phosphate HR (PrimeLab)
0 - 100
PL Phosphate HR 1 (65ml)
Plr1145
PL Phosphate HR 2 (65ml)
Plr1146
Phosphonate (PrimeLab)
0 - 20
PL Phosphonate 1 (20g)
Plr1169
PL Phosphonate 2 (20g)
Plr1170
PL Phosphonate 3 (65ml)
Plr1171
PL Phosphonate 4 (20g)
Plr1172
www.accepta.com
Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P (continued)
Contents
Range
Sulphite (PrimeLab)
5 - 50
Code
Plr1203
Plr1204
Tannin (PrimeLab)
0 - 300
PL Tannin 1 (65ml)
Plr1176
PL Tannin 2 (30ml)
Plr1177
Dt1154
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
Dt1103
0 - 60%
RefG300
Eq5022
Eq5023
www.accepta.com
10
Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P/DT
Acceptas Eng3005P/DT comprehensive combined test kit is
based on photometer and drop test chemistries and has been developed as a complete kit, specifically for water treatment professionals
involved with the maintenance and management of boiler, cooling water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all
the equipment and reagents necessary to effectively test and monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are achieved and maintained.
This test kit includes the following:
Contents
Range
Code
Eq5026
Waterproof Instructions
Eq5084
Eq5075
Eq5073
Eq5077
Eq5074
Eq5044
Eq5048
Eq5061
Eq5008
Eq5018
1 x 5/10ml Tube
Eq5015
Eq5082
Eq5119
PrimeLab Photometer
Plp1001
Pla1100
5 - 2400
PA1 (65ml)
Dt1001
PA2/TA2 (65ml)
Dt1005
TA3 (65ml)
Dt1006
5 - 2400
Dt1004
5 - 2400
www.accepta.com
Dt1007
11
Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P/DT
Contents
Range
Bromine (PrimeLab)
0.05 - 18
Code
PL DPD 1 A (30ml)
Plr1102
PL DPD 1 B (30ml)
Plr1103
Plr1104
0 - 3000
BC1/CC1 (65ml)
Dt1023
BC2 (65ml)
Dt1026
CC2 (65ml)
Dt1024
Chlorine (PrimeLab)
0.01 - 8
Plr1104
0.02 - 15
Plr1106
5 - 1200
TH2 (65ml)
Dt1046
TH3 (65ml)
Dt1044
H/TH4/CH3 (65ml)
Dt1049
TH5 (65ml)
Dt1047
5 - 1200
CH2 (65ml)
Dt1043
Dt1050
0-4
Dt1129
0 - 30
PL Iron HR 1 (65ml)
Plr1119
PL Iron HR 2 (30ml)
Plr1120
Molybdate HR (PrimeLab)
PL Molybdate 1 (65ml)
Plr1139
Nitrite (PrimeLab)
0 - 3000
PL Nitrite HR 2 (65ml)
Dt1072
Phosphate HR (PrimeLab)
0 - 100
PL Phosphate HR 1 (65ml)
Plr1145
PL Phosphate HR 2 (65ml)
Plr1146
Phosphonate (PrimeLab)
0 - 20
PL Phosphonate 1 (20g)
Plr1169
PL Phosphonate 2 (20g)
Plr1170
PL Phosphonate 3 (65ml)
Plr1171
PL Phosphonate 4 (20g)
Plr1172
www.accepta.com
12
Section 4.1
Engineers Test Kit with PrimeLab - Eng3005P/DT
Contents
Range
Sulphite (PrimeLab)
5 - 50
Code
Plr1203
Plr1204
Tannin (PrimeLab)
0 - 300
PL Tannin 1 (65ml)
Plr1176
PL Tannin 2 (30ml)
Plr1177
Dt1154
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
Dt1103
0 - 60%
www.accepta.com
RefG300
13
Section 4.1
Comprehensive Engineers Test Kit - Eng3005
Acceptas Eng3005 comprehensive combined test kit is based on
titration gun & comparator chemistries and has been developed as
a complete kit, specifically for water treatment professionals
involved with the maintenance and management of boiler, cooling
water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all the equipment and reagents necessary to effectively test and
monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are
achieved and maintained.
Contents
Range
Code
Eq5026
Waterproof Instructions
Eq5084
Eq5075
Eq5073
Eq5077
Eq5074
Eq5044
Eq5048
Eq5061
Eq5008
Eq5018
1 x Plastic Comparator
Eq5085
Eq5006
1 x 5/10ml Tube
Eq5015
Eq5082
Eq5119
Alkalinity P (Titration)
0 - 2000
PA1 (65ml)
Dt1001
Crt91002
Alkalinity M (Titration)
0 - 2000
TA4 (65ml)
Dt1004
Alkalinity OH (Titration)
0 - 2000
Dt1007
www.accepta.com
14
Section 4.1
Comprehensive Engineers Test Kit - Eng3005 (continued)
Contents
Range
Bromine (Comparator)
0-5
Code
Dt1505
Dt1506
Dt1295
Chloride (Titration)
0 - 2000
BC1/CC1 (65ml)
Dt1023
Crt91003
Chlorine (Comparator)
0-4
Dt1507
0-1
Fe5 (65ml)
Dt1110
Dt1155
Iron HR (Comparator)
0.5 - 10
Dt1247
0 - 2000
TH2 (65ml)
Dt1046
TH5 (65ml)
Dt1047
Crt91007
0 - 2000
CH2 (65ml)
Dt1043
CH1P (20g)
Dt1050
0-4
Dt1129
0 - 500
Molybdate HR (65ml)
Dt1127
Nitrite (Titration)
0 - 2000
Dt1072
Crt91009
Phosphonate (Titration)
0 - 20
P1/2 (65ml)
Dt1514
P3 (65ml)
Dt1080
P4L (65ml)
Dt1291
Crt91004
Phosphate HR (Comparator)
0 - 80
PB1 (65ml)
Dt1111
PB2 (65ml)
Dt1112
www.accepta.com
15
Section 4.1
Comprehensive Engineers Test Kit - Eng3005 (continued)
Contents
Range
Sulphite (Titration)
0 - 100
Code
S1 (40g)
Dt1092
Crt91005
0 - 300
TN1 (40g)
Dt1094
TN2 (65ml)
Dt1095
Dt1154
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
Dt1103
0 - 60%
RefG300
Eq5022
Eq5023
www.accepta.com
16
Section 4.1
Engineers Test Kit with Titration Syringe - Eng3005TS
Acceptas Eng3005TS comprehensive combined test kit is based
on titration syringe & comparator chemistries and has been developed as a complete kit, specifically for water treatment professionals involved with the maintenance and management of boiler,
cooling water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all the equipment and reagents necessary to effectively test and
monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are
achieved and maintained.
This test kit includes the following:
Contents
Range
Code
Eq5026
Waterproof Instructions
Eq5084
Eq5075
Eq5073
Eq5077
Eq5074
Eq5044
Eq5048
Eq5061
Eq5008
Eq5018
1 x Plastic Comparator
Eq5085
Eq5006
1 x 5/10ml Tube
Eq5015
Eq5082
Eq5119
Alkalinity P (Titration)
0 - 2000
PA1 (65ml)
Dt1001
Crt91002
Alkalinity M (Titration)
0 - 2000
TA4 (65ml)
Dt1004
Alkalinity OH (Titration)
0 - 2000
PA3 (65ml)
Dt1007
www.accepta.com
17
Section 4.1
Engineers Test Kit with Titration Syringe - Eng3005TS
(continued)
Contents
Range
Bromine (Comparator)
0-5
Code
Dt1505
Dt1506
Dt1295
Chloride (Titration)
0 - 2000
BC1/CC1 (65ml)
Dt1023
Crt91003
Chlorine (Comparator)
0-4
Dt1507
0 - 2000
TH2 (65ml)
Dt1046
TH5 (65ml)
Dt1047
Crt91007
0 - 2000
CH2 (65ml)
Dt1043
CH1P (20g)
Dt1050
0-4
Dt1129
0-1
FE5 (65ml)
Dt1110
Dt1155
0 - 500
Molybdate HR (65ml)
Dt1127
Nitrite (Titration)
0 - 2000
Dt1072
Crt91009
Phosphonate (Titration)
0 - 20
P1/2 (65ml)
Dt1514
P3 (65ml)
Dt1080
P4L (65ml)
Dt1291
Crt91004
Phosphate HR (Comparator)
0 - 80
PB1 (65ml)
Dt11111
PB2 (65ml)
Dt1112
www.accepta.com
18
Section 4.1
Engineers Test Kit with Titration Syringe - Eng3005TS
(continued)
Contents
Range
Sulphite (Titration)
0 - 100
Code
S1 (40g)
Dt1092
Crt91005
10 - 300
TN1 (40g)
Dt1094
TN2 (65ml)
Dt1095
Dt1154
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
Dt1103
0 - 60%
RefG300
Eq5023
www.accepta.com
19
Section 4.1
Engineers Test Kit with Drop Tests - Eng3005DT
Acceptas Eng3005DT comprehensive combined test kit is based
on photometer and titration gun chemistries and has been developed as a complete kit, specifically for water treatment professionals involved with the maintenance and management of boiler, cooling water and closed water systems.
Water systems require careful test monitoring to ensure the correct
risk management regimes and water treatment programmes are
maintained at all times. Failure to maintain the correct water
system conditions can lead to serious problems, including reduced
system efficiency, the build-up of scale, potentially damaging
corrosive water conditions and increased microbiological activity,
which may result in the proliferation of Legionella bacteria and the
increased risks associated with Legionnaires disease.
Our comprehensive combined test kit is presented in its own robust Aluminium case and includes all
the equipment and reagents necessary to effectively test and monitor boiler, cooling and closed
system waters to ensure optimum operating conditions are achieved and maintained.
This test kit includes the following:
Contents
Range
Code
Eq5026
Waterproof Instructions
Eq5084
Eq5075
Eq5073
Eq5077
Eq5074
Eq5044
Eq5048
Eq5061
Eq5008
Eq5018
1 x Plastic Comparator
Eq5085
Eq5006
1 x 5/10ml Tube
Eq5015
Eq5082
EC500
5 - 2400
PA1 (65ml)
Dt1001
PA2/TA2 (65ml)
Dt1005
TA3 (65ml)
Dt1006
5 - 2400
www.accepta.com
Dt1004
20
Section 4.1
Engineers Test Kit with Drop Tests - Eng3005DT
Contents
Range
5 - 2400
Code
Dt1006
0-5
Dt1505
Dt1506
Dt1295
0 - 3000
BC1/CC1 (65ml)
Dt1023
BC2 (65ml)
Dt1026
CC2 (65ml)
Dt1024
Chlorine (Comparator)
0-4
Dt1507
5 - 1200
TH2 (65ml)
Dt1046
H/TH4/CH3 (65ml)
Dt1049
TH5 (65ml)
Dt1047
TH3 (65ml)
Dt1044
5 - 1200
CH2 (65ml)
Dt1043
Dt1050
0-4
Dt1129
0-1
FE5 (65ml)
Dt1110
Dt1155
Iron HR (Comparator)
0.5 - 10
Dt1247
0 - 500
Molybdate HR (65ml)
Dt1127
0-2000
N1 (65ml)
Dt1072
N2 (65ml)
Dt1073
0 - 20
P1/2 (65ml)
Dt1514
P3 (65ml)
Dt1080
P4L (65ml)
Dt1291
P5 (65ml)
Dt1075
www.accepta.com
21
Section 4.1
Engineers Test Kit with Drop Tests - Eng3005DT
Contents
Range
Phosphate (Comparator)
0-80
Code
PB1 (65ml)
Dt1111
PB2 (65ml)
Dt1112
5 - 300
S1 (40g)
Dt1092
S2 (65ml)
Dt1093
10-300
TN1 (40g)
Dt1094
TN2 (65ml)
Dt1095
Dt1109
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
Dt1103
0-60%
www.accepta.com
RefG300
22
Section 4.2
Cooling (Open & Closed) Water Test Kit - Cool3002
Acceptas Cool3002 comprehensive Cooling (Open & Closed)
Water Test Kit is based on drop test and colour comparator
chemistries and has been developed specifically for engineers
and water treatment professionals involved with the maintenance and management of both open and closed cooling systems to
ensure optimum operating conditions.
Cooling water systems require careful test monitoring to ensure
the correct water conditions are maintained at all times. Failure
to maintain correct treatment programs can lead to serious
problems including reduced efficiency, the build-up of scale,
potentially damaging corrosive water conditions and increased
microbiological activity, which may include the growth of
Legionella bacteria. Replacements and components are
available, please refer to replacement reagent section.
The Cooling (Open & Closed) Water test kit is presented in its
own robust case and includes all the equipment and reagents necessary to effectively test and monitor system waters.
Contents
Range
Code
Eq5027
Waterproof instructions
Eq5084
Eq5075
Eq5073
Eq5044
Eq5048
Eq5061
Eq5018
1 x Plastic Comparator
Eq5085
Eq5006
1 x 5/10ml Tube
Eq5015
0 - 14
pH1
0 - 20.00 mS
EC1
5 - 2400
TA4 (65ml)
Dt1004
PA2/TA2 (65ml)
Dt1005
TA3 (65ml)
Dt1006
Bromine (Comparator)
0-5
Dt1505
Dt1506
Dt1295
0 - 3000
BC1/CC1 (65ml)
Dt1023
BC2 (65ml)
Dt1026
CC2 (65ml)
Dt1024
www.accepta.com
23
Section 4.2
Cooling (Open & Closed) Test Kit - Cool3002 (continued)
Contents
Range
5 - 1200
Code
CH2 (65ml)
Dt1043
Dt1050
5 - 1200
TH2 (65ml)
Dt1046
H/TH4/CH3 (65ml)
Dt1049
TH5 (65ml)
Dt1047
TH3 (65ml)
Dt1044
0-4
Dt1129
0-1
FE5 (65ml)
Dt1110
Dt1155
Iron HR (Comparator)
0 - 10
Dt1247
0 - 500
Molybdate HR (65ml)
Dt1127
0 2000
N1 (65ml)
Dt1072
N2 (65ml)
Dt1073
0 - 20
P1/4L (65ml)
Dt1514
P5 (65ml)
Dt1075
Dt1109
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
www.accepta.com
24
Section 4.2
Cooling (Open & Closed) Test Kit (Backpack) - Cool3002BP
Acceptas cooling (Open & Closed) Test Kit (Backpack Version)
is designed for use on Cooling Towers and many types of
Closed Water Systems such as Chilled Water Circuits and Heating systems.
The Backpack Test Kit has most of the reagents and
components that are normally contained in a standard Open &
Closed Test Kit but formatted into a backpack design for use by
the commuter in busy commercial areas.
It includes all the equipment and reagents necessary to perform
the below noted tests. Replacement reagents and components
are available which make this kit a lasting addition to any water
treatment professional. Simple to use and fully portable.
The Cooling (Open & Closed) Backpack Test Kit is presented in its own robust case and harness and
includes all the equipment and reagents necessary to effectively test and monitor system waters.
This test kit includes the following:
Contents
Code
Eq5026E
Waterproof Instructions
Eq5084
1 x Plastic Comparator
Eq5085
Eq5006
Eq5064
Eq5018
Eq5044
Eq5048
Eq5073
Eq5075
1 x 5/10ml Tube
Eq5015
0 - 14
pH1
0 - 20.00 mS
EC1
5 - 2400
TA4 (65ml
Dt1004
PA2/TA2 (65ml)
Dt1005
TA3 (65ml)
Dt1006
5 - 1200
TH2 (65ml)
Dt1046
H/TH4/CH3 (65ml)
Dt1049
TH3 (65ml)
Dt1044
TH5 (65ml)
Dt1047
www.accepta.com
25
Section 4.2
Cooling (Open & Closed) Test Kit (Backpack) - Cool3002BP
(continued)
Contents
Range:
5 - 1200
Code
CH2 (65ml)
Dt1043
Dt1050
0-4
Dt1129
0-3000
BC1/CC1 (65ml)
Dt1023
BC2 (65ml)
Dt1026
CC2 (65ml)
Dt1024
Iron LR (Comparator)
0-1
Dt1110
Iron HR (Comparator)
0.5 -10
Dt1247
Bromine (Comparator)
0-5
Dt1505
Dt1506
Dt1295
0-500
Molybdate HR (65ml)
Dt1127
0-2000
N1 (65ml)
Dt1072
N2 (65ml)
Dt1073
0-20
P1/4L (65ml)
Dt1514
P5 (65ml)
Dt1075
Dt1109
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
* For true Soluble and Total Iron determination, Sulphuric Acid 50% and 0.45 micron filter papers
are required and can be ordered separately.
www.accepta.com
26
Section 4.3
Closed Water Systems Test Kit - Clo3003/Clo3003F
Acceptas comprehensive Closed Water System test kit is based
on colour comparator and drop test chemistries and has been
developed specifically for engineers and water treatment
professionals involved with the maintenance and management
of closed systems to ensure optimum operating conditions.
Closed water systems require careful test monitoring to ensure
the correct water conditions are achieved during the course of a
treatment programme.
Failure to maintain the correct dosage levels can lead to scaling,
corrosion and increased biological activity which can lead to
potentially unstable water conditions.
This kit is presented in its own robust case and includes all the equipment and reagents necessary to
effectively test and monitor Closed Water System to ensure optimum operating conditions are
achieved and maintained.
This test kit includes the following:
Contents
Range
Code
Eq5028/2
Waterproof instructions
Eq5084
Eq5168
1 x Plastic Comparator
Eq5085
Eq5006
1 x 5/10ml Tube
Eq5015
0 - 14
pH1
0 - 20.00 mS
EC1
Iron HR (Comparator)
0.5 - 10
FE10 (65ml)
Dt1247
0 - 500
Molybdate HR (65ml)
Dt1127
0 - 2000
N1 (65ml)
Dt1072
N2 (65ml)
Dt1073
Dt1109
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
Please Note: CLK003F includes Filtration & Sulphuric Acid 50% for True Soluble and Total Iron.
Liquid equivalent reagents are available on request.
www.accepta.com
27
Section 4.4
Chlorination Test Kit - Chlor3004
Acceptas chlorination test kit is based on colour comparator
chemistry and has been developed specifically for engineers
and water treatment professionals involved with the chlorination
and
disinfection of water systems.
Water system chlorinations require careful test monitoring to
ensure the correct water conditions are achieved during the
course of the disinfection procedure. Failure to achieve the
correct dosage levels can lead to unsuccessful disinfections,
whilst elevated levels can lead to potentially corrosive water
conditions.
This kit is presented in its own robust case and includes all the
equipment and reagents necessary to effectively test and monitor the chlorination procedure.
This kit includes all the reagents and equipment required to allow the monitoring of low range
chlorine (0 to 4ppm) and high range chlorine (0 to 300ppm). These are required to ensure the correct
system conditions are achieved.
This test kit includes the following:
Contents
Range
Code
Eq5030
Waterproof instructions
Eq5084
1 x Plastic Comparator
Eq5085
Eq5006
1 x Tablet Crusher
Eq5079
0 - 14
Chlorine LR (Comparator)
0-4
pH1
Dt1505
Dt1506
Dt1507
Chlorine HR (Comparator)
10 - 300
Chlorine HR (65ml)
Dt1179
Dt1180
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
www.accepta.com
28
Section 4.5
Boiler Water Test Kit - Blr3001
Acceptas comprehensive Boiler Water Test Kit is based on a
colour comparator and drop test chemistries and has been developed specifically for engineers and water treatment professionals who are involved with the maintenance and management of boilers and boiler systems.
Boiler Water and feed-water systems require careful test
monitoring to ensure the correct water conditions are maintained
at all times. Failure to maintain the correct water treatment
programs can lead to serious problems including reduced boiler
efficiency, scale, corrosive water conditions and reduced steam
purity.
This professional Boiler Water Test kit is presented in its own robust case and includes all the
equipment and reagents necessary to effectively test and monitor system waters to ensure optimum
operating conditions are achieved and maintained.
This test kit includes the following:
Contents
Range
Code
Eq5027
Waterproof Instructions
Eq5084
Eq5075
Eq5073
Eq5044
Eq5048
Eq5018
1 x 5/10ml Tube
Eq5015
1 x Plastic Comparator
Eq5085
Eq5006
0 - 14
pH1
0 - 20.00 mS
EC1
5 - 2400
PA1 (65ml)
Dt1001
PA2/TA2 (65ml)
Dt1005
TA3 (65ml)
Dt1006
5 - 2400
Dt1004
5 - 2400
Dt1007
0 - 3000
BC1/CC1 (65ml)
Dt1023
BC2 (65ml)
Dt1026
CC2 (65ml)
Dt1024
www.accepta.com
29
Section 4.5
Boiler Water Test Kit - Blr3001 (continued)
Contents
Range
0-4
Code
Dt1129
5 - 120
TH2 (65ml)
Dt1046
TH5 (65ml)
Dt1047
TH3 (65ml)
Dt1043
Phosphate (Comparator)
0 - 80
PB1 (65ml)
Dt1111
PB2 (65ml)
Dt1112
5 - 300
S1 (40g)
Dt1092
S2 (65ml)
Dt1093
Dt1109
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
Dt1103
www.accepta.com
30
Section 4.6
Legionella Compliance Test Kit - Leg3006
Acceptas Legionella compliance kit is based on colour comparator and drop test chemistries and has been developed specifically for engineers and water treatment professionals involved in
the weekly and monthly analysis of water systems.
Cooling Water systems require careful test monitoring to ensure
the correct water conditions are achieved to reduce the risk of
Legionella. Failure to keep the system under control can lead to
scale, corrosion and the growth of the potentially fatal Legionella
bacteria.
This kit is presented in its own robust case and includes all the
equipment and reagents necessary to effectively monitor the
water conditions.
Replacement reagents and other components are available, please refer to the relevant section.
This test kit includes the following:
Contents
Range
Code
Eq5027
Waterproof Instructions
Eq5084
Eq5168
Eq5177
Eq5018
1 x 5/10ml Tube
Eq5015
1 x Plastic Comparator
Eq5085
Eq5006
0 - 14
pH1
0 - 20.00 mS
EC1
5 - 2400
TA4 (65ml)
Dt1004
PA2/TA2 (65ml)
Dt1005
TA3 (65ml)
Dt1006
Bromine (Comparator)
0-5
Dt1505
Dt1506
Dt1131
0 - 3000
BC1/CC1 (65ml)
Dt1023
BC2 (65ml)
Dt1026
CC2 (65ml)
Dt1024
www.accepta.com
31
Section 4.6
Legionella Compliance Test Kit - Leg3006 (continued)
Contents
Range
5 - 1200
Code
TH2 (65ml)
Dt1046
TH5 (65ml)
Dt1047
TH3 (65ml)
Dt1044
H/TH4/CH3 (65ml)
Dt1049
5 - 1200
CH2 (65ml)
Dt1043
Dt1050
0-4
Dt1129
0-1
FE5 (65ml)
Dt1110
Dt1109
pH 4 (65ml)
Dt1119
pH 7 (65ml)
Dt1118
pH 10 (65ml)
Dt1161
www.accepta.com
32
Section 4.7
Resin Test Kit - Res3008
Ion exchange Resins should be checked when the plant is
serviced to determine if the ion exchange resin is suffering
from fouling or damage which will reduce the plant efficiency.
Acceptas portable and easy to use kit allows the qualitative
analysis of ion exchange resins for the three main problems
encountered when water softeners or ion exchange plant
efficiency is reduced.
The ion exchange resin can be checked for Iron fouling,
organic fouling and resin bead optical assessment. Failure to
maintain good quality resins will lead to serious problems
including reduced efficiency and the build-up of scale and
increased microbiological activity, which may include the
growth of Legionella bacteria.
The Resin Test kit is presented in its own robust case and includes all the equipment and reagents
necessary to effectively test and monitor the qualitative condition of ion exchange resins.
This test kit includes the following:
Contents
Range
Code
Eq5030
Waterproof Instructions
Eq5084
1 x Optic Magnifier
Eq5034
Eq5018
Eq5382
Dt1338
Dt1336
Dt1339
Dt1210
www.accepta.com
33
Section 4.8
Manual Silt Density Kit SDI001
Depleting supplies of fresh water, ground water contamination
and the rising cost of water have compelled industries to
increasingly turn to the desalination of brackish/sea water as
well as water recovered from treated industrial effluent and
secondary treated municipal sewage.
All these recycled water systems use reverse osmosis (RO)
system for removal of dissolved solids. The presence of finely
divided particles in feed water to an RO system can cause
serious problems as they are too small to be retained by
conventional pre-treatment systems and they find their way to
the RO membrane.
The function of an RO membrane is to concentrate dissolved
solids on one side of the membrane and allow water molecules
to permeate through the other side. Suspended, colloidal
particles are larger than dissolved solids and are rejected by the
membrane.
These fine un-dissolved suspended particles tend to settle on the surface and in the process, foul the
membrane. The net result is an increase in feed pressure, reduced flow and high conductivity of
permeate. Spiral wound and hollow fine fibre membranes are the most vulnerable and once fouled,
cleaning of the element is often difficult.
Use of the Kit
Silt Density Index (SDI) is an empirical test developed for measuring the rate of fouling of nano
filtration (NF) or RO membranes.
Suspended solids and colloidal materials in feed water are one of the biggest problems in reverse
osmosis systems. Although most systems have some pre-treatment, including 5-micron pre-filters,
these fine particles are responsible for the fouling of reverse osmosis membranes.
In order to measure the degree of this fouling problem, a concept called Silt Density Index is used.
Here, filtration rates are calculated by exposing a 0.45-micron filter to the feed water under pressure.
An SDI of less than 5 is typically considered acceptable for reverse osmosis systems. This means
membranes should foul at a very low rate at SDI values of less than 5. Although this concept works
most of the time, there are exceptions when a lower SDI (less than 3) is desirable due to the nature
of the suspended solids in feed water.
Contents
Range
Code
Waterproof Instructions
Eq5084
Eq5086
Eq5181
Eq5183
Stopwatch/Clock
Eq5239
Dt1240
SDI Assembly
Dt1182
www.accepta.com
34
Section 5.0
Pocket Test Meters
www.accepta.com
35
Section 5.1
PH1 - pH/Temperature Meter
Acceptas waterproof pH1 Meter has a built in smart chip which offers many
advanced functions and features for a stick style pH Meter.
Features:
LCD display.
Specifications:
pH:
Temperature:
Resolution:
Accuracy:
Power:
Dimensions:
Weight:
0.00 to 14.00pH
0 to 90C
0.01 pH
0.01pH, 1.8F/1C
2 x CR2032 Button Batteries
195 x 40 x 36mm
150g
Optional Extra:
Redox Probe
Code:
RE1P
Replacement Probe:
pH Probe
Code:
pH1P
www.accepta.com
36
Section 5.2
EC1 - Conductivity/TDS/Temperature/Salinity Meter
Acceptas waterproof EC1 Meter has a built in smart chip which offers many
advanced functions and features for a stick style EC Meter.
Features
LCD Display.
Specifications
Ranges
Max Resolution
Basic Accuracy
Conductivity:
0.1S/cm
1S/cm
0.01mS/cm
0.1ppm (mg/L)
1ppm (mg/L)
0.01ppt (g/L)
2% FS
Temperature:
Power:
0 to 199.9S/cm
200 to 1999S/cm
2.00 to 19.99mS/cm
0 to 99.9ppm (mg/L)
100 to 999ppm (mg/L)
1.00 to 9.99ppt (g/L)
0 to 1000ppm
100 to 999ppm (mg/L)
1.00 to 12.00ppt
0 to 90F
2 x CR2032 Batteries
Dimensions:
36 x 173 x 41mm
Weight:
110g
Replacement Probe:
EC/TDS Probe
EC1P
TDS:
Salinity
2% FS
1ppm / 0.01ppt
1ppm (mg/L)
0.1C
www.accepta.com
0.2C
37
Section 5.3
PH100 - Extech pH/Temperature Meter
The waterproof ExStik pH100 Meter has a built in smart chip which offers
advanced functions and features to a stick style pH Meter not found anywhere
else and has a robust flat surface electrode.
Features:
Optional weighted base (EX006) holds plastic cup and ExStik Meter.
Specifications:
pH:
Temperature:
Resolution:
Accuracy:
Power:
Dimensions:
Weight:
0.00 to 14.00pH
23 to 194F (-5 to 90C)
0.01pH, 0.1
0.01pH, 1.8F/1C
4 x CR2032 Button Batteries
35.6 x 172.7 x 40.6mm
110g
Optional Extra:
Code:
EX006
Replacement Probe:
Probe (PH105)
Code:
Eq5039
www.accepta.com
38
Section 5.4
EC400 - Extech Conductivity/TDS/Temp/Salinity Meter
The waterproof ExStik Conductivity/TDS/Salinity Meter offers one high accuracy
multi-range sensor which measures four parameters (Conductivity, TDS, Salinity
and Temperature).
Features
Auto ranging meter offers 3 ranges to measure, pure water, salinity solution, waste, boiler and cooling water using the same conductivity cell.
Large digit, digital display with analog bar graph to indicate sample trends.
Self calibration on power up, data hold, Auto Power Off & low battery
Indication.
Specifications
Ranges
Max Resolution
Basic Accuracy
Conductivity:
0.1S/cm
1S/cm
0.01mS/cm
0.1ppm (mg/L)
1ppm (mg/L)
0.01ppt (g/L)
0.1ppm (mg/L)
1ppm (mg/L)
0.01ppt (g/L)
0.1F/C
2% FS
Temperature:
Power:
0 to 199.9S/cm
200 to 1999S/cm
2.00 to 19.99mS/cm
0 to 99.9ppm (mg/L)
100 to 999ppm (mg/L)
1.00 to 9.99ppt (g/L)
0 to 99.9ppm (mg/L)
100 to 999ppm (mg/L)
1.00 to 9.99ppt (g/L)
32 to 149F (0 to 65C)
4 x CR44W Batteries
Dimensions:
36 x 173 x 41mm
Weight:
110g
Optional Extras:
Weighted Base and 5
Solution Caps
Code:
EX006
Replacement Probe:
EC405 Probe
Code:
Eq5032
TDS:
Salinity:
www.accepta.com
2% FS
2% FS
1.8F/1C
39
Section 5.5
EC500 - Extech Combined pH/Conductivity/TDS/
Temperature Meter
The waterproof ExStik II pH/Conductivity Meter Combination comes with a
rugged flat surface pH electrode and an Auto-ranging high accuracy conductivity
cell.
Features
Adjustable Conductivity to TDS ratio from 0.4 to 1.0; 0.5 fixed Salinity ratio.
Auto Power Off and Low Battery Indicator & waterproof to IP57.
EC500 meter includes electrode, protective sensor cap, sample cup with
cap, four 3V CR-2032 button batteries and 1.2m neck strap.
Specification
Range
Max Resolution
Basic Accuracy
Conductivity:
0.1S/cm
2% FS
0.1ppm (mg/L)
2% FS
pH:
0 to 199S/cm
200 to 1999S/cm
2.00 to 19.99mS/cm
0 to 99.9ppm (mg/L)
100 to 999ppm (mg/L)
1.00 to 9.99ppt
0.00 to 14.00pH
0.01pH
0.01pH
Temperature:
Waterproof:
Memory:
Dimensions:
Weight:
Optional Extras:
Weighted Base and 5
Solution Cups
Code: EX006
Replacement Probe:
Probe (EC505)
Code: Eq5041
TDS/Salinity:
www.accepta.com
1.8F/1C
40
Section 5.6
CL200 - Extech Total Chlorine/Temperature Meter
The waterproof ExStik CL200 Chlorine Meter gives a direct reading of Total
Chlorine down to 0.01ppm and is unaffected by colour/turbidity of the sample.
Features
Direct reading of Total Chlorine provides fast and easy measurements (less
than 2 minutes).
Complete with meter and flat surface Chlorine electrode, ExTab reagent
tablets (50 tests), protective sensor cap, sample cup with cap, four 3V
CR-2032 Button Batteries, and a 1.2m neck strap.
Specifications
Range in ppm:
Temperature:
Resolution:
Accuracy:
Power:
Dimensions:
Weight:
Optional Extras
Weighted Base and 5 Solution Cups:
Replacement Probe (CL205)
Code: EX006
Code: Eq5040
www.accepta.com
41
Section 5.7
DO600 - Extech Dissolved Oxygen/Temperature Meter
The waterproof ExStik II Dissolved Oxygen Meter incorporates an easy to
replace screw on membrane cap with optional extension cables.
Features
Waterproof to IP57.
Specification
Range
Max Resolution
Basic Accuracy
DO (saturation mode):
DO (concentration mode):
Temperature:
0 to 200.0%
0 to 20.00ppm (mg/L)
32 to 122F (0 to 50C)
0.1%
0.01ppm (mg/L)
0.1F/C
2% FS
0.4ppm (mg/L)
1.8F (1C)
Dimensions
Weight:
Power:
36 x 176 x 41mm
110g
4 x CR2032 Button Batteries
Optional Extras
Weighted Base and 5 Solution Cups:
Code: EX006
Replacement Probe:
Code: D0605
www.accepta.com
42
Section 5.8
RE300 - Extech ORP Meter
The Extech ORP Meter has flat surface electrodes which provides On-the-Spot
measurements and also has a large display with bar-graph.
Features:
Memory stores and recalls 15 readings and saves last calibrated value.
Large 3-1/2 digit (2000 count) digital display with bar graph.
Waterproof IP57 floats in water & protects the meter in wet environments.
Complete with meter and electrode, protective sensor cap, sample cup with
cap, four 3V CR-2032 Button Batteries and neck strap
Specifications
ORP (mV):
Resolution:
Accuracy:
Power:
Dimensions:
Weight:
999 to 999mV
1mV
4mV
4 x CR2032 Button Batteries
35.6 x 172.7 x 40.6mm
110g
Optional Extras
Weighted Base and 5 Solution Cups:
Code: EX006
Code: Eq5031
www.accepta.com
43
Section 5.9
Refractometer - Glycol Tester (RefG300)
Acceptas refractometer is a precision optical instrument designed
to measure the concentration of Glycol as PEG or MEG displayed
as a % and freeze point
It is easy to use, you simply place a few drops of the treated solution with the pipette included on to the prism glass and hold up to
the light. You can then read the concentration of Glycol in % or
freeze point on to the lens.
Our Refractometer has
compensation system.
built-in
automatic
temperature
Measuring Range
Ethylene Glycol: 60C - 0C with a resolution of 5C
Polypropylene: 50C - 0C with a resolution of 5C
Battery Acid: 1.100-1.400sg with a resolution of 0.01sg
Other Refractometers for Coolants, Brix, Sugars etc. are available on request.
Please contact us for details.
www.accepta.com
44
Section 6.0
Professional Test Meters
www.accepta.com
45
Section 6.1
Martini MI806 - 4 in 1 pH/Conductivity/TDS/Temp
The Martini Mi806 is a multi-function portable meter measuring
pH, Conductivity, TDS and temperature using a single probe.
Specifications
Range:
pH
EC
TDS
Temp
Resolution: pH
EC
TDS
Temp
Accuracy (25C): pH
EC/TDS
Temp
Typical EMC Deviation: pH
EC/TDS
Temp
Typical Compensation:
pH Calibration:
EC Calibration:
EC/TDS Conversion Factor:
Probe (Included):
0.00 to 14.00 pH
0.00 to 20.00 mS/cm
0.00 to 10.00 ppt
0.0 to 60.0C / 32.0 to 140.0F
0.01pH
0.1 mS/cm
0.01 ppt
0.1C / 0.1F
0.01 pH
2% FS
0.5C / 1F
0.02 pH
2% FS
0.5C / 1F
Automatic from 0 to 60C;
6 adj. from 0.0 to 2.4%/C
1 or 2-point with automatic buffer recognition
Automatic, 1 point
Adj. from 0.45 to 1.00
Mi806P (MA851D/1) amplified pH/EC/TDS/Temperature
probe with DIN connector and 1m cable
Environment:
Battery Type (Included):
Battery Life:
Auto-off:
Dimensions:
Weight (with battery)
Replacment Probe:
MI806 Probe
Code: MI806P
www.accepta.com
46
Section 6.2
Eutech pH11 - pH/Temperature Meter
The Eutech pH11 is a simple to use, accurate, reliable
hand held meter which has been designed to handle the
tough environment of field work.
for
Specifications
Ranges
Max Resolution
Basic Accuracy
pH:
mV:
-2 to 16.00
0 to 1000 mV
0.01pH
0.01pH
0.02 pH
2mV
Temperature:
-5 to 105C
0.1C
0.5C
Power:
4 x AAA Batteries
Dimensions:
85 x 185 x 40 mm
Weight:
224g
www.accepta.com
easy
47
Section 6.3
Eutech CON 11 - Conductivity Meter
The Eutech CON 11 is a simple to use, accurate, reliable
hand held meter which has been designed to handle the
tough environment of field work.
Specifications
Ranges
Max Resolution
Basic Accuracy
Conductivity:
0 to 19.99 S/cm
20.0 to 199.9 mS/cm
2.00 to 19.99 mS/cm
20.0 to 199.9 mS/cm
0.1S/cm
0.01mS/cm
1%
0.1C
1.8F/1C
Temperature:
-9 to 120C
Power:
4 x AAA Batteries
Dimensions:
85 x 185 x 40 mm
Weight:
224g
www.accepta.com
48
Section 6.4
Eutech PC300 - Combined pH/Condy/TDS/Temp Meter
The Eutech PC 300 is designed to readily withstand the
rigours of portable analysis, while reliably measuring pH,
Conductivity and Temperature in a simple professional
manner.
Specifications
Ranges
Max Resolution
Basic Accuracy
pH:
-2 to 16.00
0.01pH
0.02 pH
mV:
0 to 1000 mV
1 Mv
2mV
Temperature:
-5 to 105C
0.1C
0.5C
Power:
4 x AAA Batteries
Dimensions:
85 x 185 x 40 mm
Weight:
224g
www.accepta.com
49
Section 6.5
Jenway 350 - pH Meter
The Jenway 350 pH Meter offers simple yet professional
performance for the operator who requires reliable results
from trusted technology. With its single pH input and
manual temperature compensation the 350 is easy to use,
but also offers such advanced features as the 32 reading
non-volatile memory.
Features
The custom back-lit liquid crystal display simultaneously shows the pH reading and the manually set
temperature compensation value that is simply adjusted with the up and down arrow keys. A one or
two point calibration can be selected and, for ease of operation, automatic buffer recognition can be
used. In special applications this can be overridden, enabling calibration to be set at any two points
across the full pH range.
An indication of battery life is also permanently shown on the display. An automatic switch off facility
helps to conserve battery life. This product is ideal for use in field or any portable situation.
Specifications
pH Range:
Resolution (Accuracy):
Manual Temperature Compensation:
Resolution:
Auto Buffer Recognition:
Calibration:
Power:
Battery Life:
Size:
Weight:
-2.00 to 16.00pH
0.01pH ( 0.02pH)
0 to 100C / 32 to 212F
0.1C / 1F
4.00, 7.00, 9.22 & 10.00 (manual override)
User selectable 1 or 2 point
2 x AA batteries
500 hours typical (@25C with alkaline cells)
175 x 75 x 35 mm
250g
www.accepta.com
50
Section 6.6
Jenway 470 - Conductivity/TDS/Temp Meter
The Jenway 470 Conductivity/TDS/Temp Meter is a general
purpose hand held meter offering a wide measuring range, which
is further complimented by the auto-ranging function that ensures
results are displayed with the highest resolution that can be
achieved.
Features
Calibration can be carried out automatically against standard solutions at 10S, 84S, 1413S and
12.88mS or a manual calibration can be made against any other standard value.
Standard conductivity measurements can be made quickly and easily using the default settings but
for more complex applications a full range of adjustments can be made. The reference temperature
can be set to 18, 20 or 25C and the temperature coefficient set from 0 to 4%/C. When using the
alternative TDS range the E/C ratio can be set from 0.5 to 0.8 to ensure conformance with all
operating procedures.
A simple dual function memory bar enables up to 32 readings to be stored and recalled from the nonvolatile internal memory.
An indication of battery life is also permanently shown on the display. An automatic switch off facility
helps to conserve battery life. This product is ideal for field or any portable situation.
Specifications:
Conductivity:
Ranges:
Resolution (Accuracy):
TDS Ranges:
Resolution (Accuracy):
Temperature Range:
Resolution Accuracy:
ATC & Manual ranges:
Cell constant:
Reference Temperature:
Temperature Coefficient:
Auto Standard Recognition:
Probe input:
Power:
Battery Life:
Size:
Weight:
6 switched ranges
0 to 19.99S - 0 to 1999mS*
0.1S to 1mS* (0.5% 2 digits)
6 switched ranges
0 to 19.99mg/l - 0 to 1999g/l*
0.01mg/l to 1g/l* (0.5% 2 digits)
-10 to 105C / 14 to 221F
0.1C/1F (0.5C/1F)
0 to 100C / 32 to 212F
Digitally settable 0.01 to 19.99
18, 20 or 25C settable
0.00 to 4.00%/C linear
10S, 84S, 1413S or 12.88mS (manual override)
Mini-DIN conductivity/temperature
2 x AA batteries
500 hours typical (@25C with alkaline cells)
175 x 75 x 35 mm
250g
* only with cell constant > 5
www.accepta.com
51
Section 6.7
Jenway 430 - Combined pH/Conductivity/TDS/Temp Meter
The 430 is designed to readily withstand the rigours of portable analysis, while reliably measuring pH and Conductivity in a simple and
professional manner.
Features
This product allows the simultaneous readout of pH, Conductivity or TDS and Temperature using the
custom backlit liquid crystal display. Calibrations are clearly indicated, together with the parameter in
error.
It offers 1 or 2 point pH calibration and automatic buffer recognition with manual override.
Conductivity calibration can be performed on standard solutions or by direct cell constant entry. The
conductivity/TDS range is automatically selected for optimum resolution and temperature
compensated using an adjustable temperature coefficient.
The 430 is supplied with a combined conductivity and pH probe assembly (a temperature sensor is
also incorporated to provide automatic temperature compensation). The probe connects to the
instrument via a single mini-DIN connector for operator convenience.
An indication of battery life is also permanently shown on the display. An automatic switch off facility
helps to conserve battery life. This product is ideal for field or any portable situation.
Specifications:
pH Range (1 or 2 point call):
Resolution:
Accuracy:
Conductivity Ranges:
Resolution:
Accuracy:
TDS Ranges:
Resolution:
Accuracy:
Temperature Ranges:
Resolution:
Accuracy:
ATC Range:
Manual Temp. Comp.:
Auto Buffer Recognition:
Auto Standard Recognition:
Cell Constant:
EC Ration (TDS):
Reference Temperature:
Temperature Coefficient:
Power:
Battery Life:
Size:
Weight:
0 to 14pH
0.01pH
0.02pH
5 switched ranges: 0 to 19.99S - 0 to 199.9mS
0.01S, 0.S, 1S, 0.01mS, 0.1mS
0.5% 2 digits
5 switched ranges: 0 to 19.99mg/l - 0 to 199.9g/l
0.01mg/l, 0.1mg/l, 1mg/l, 0.01g/l, 0.1g/l
0.5% 2 digits
-9.9 to +99.9C / 32 to 212F
0.1C/ 1F
0.5C / 1F
0 to 99.9C / 32 to 212F
0 to 99.9C / 32 to 212F
4, 7, 9.22 and 10.00 (manual override facility)
10S, 84S, 1413S & 12.88mS
0.01 to 19.99
0.50 to 0.80
18, 20 or 25C
0.00 to 4%/C
2 x AA batteries
100 hours typical (@25C with alkaline cells)
175 x 75 x 35 mm
250g
www.accepta.com
52
Section 6.8
TRANSEC - Conductivity/TDS/Salinity/Temp Meter
The Conductivity/TDS Meter HC3010 is a highly sophisticated meter with
ability to automatically display and convert in Siemen (S), mSiemen (Ms),
TDS in ppm and Salinity in ppt.
The meter is versatile and able to preset at different conversion factors.
User can select to display in Conductivity or TDS. Its 99 data memory
coupled with real time clock enable you to record reading with date and
time.
For QC control, data can be analysed to display maximum and minimum
readings over all saved data. The meter comes complete in a hard case
with a set of calibration fluids for on the spot calibration.
Auto-range measurement
Multi range display of conductivity and TDS
Dual conductivity or TDS and temperature reading display
Save up to 99 data in memory with real time clock
Able to show maximum and minimum reading over saved data
Stability indicator prompts whenever reading stabilizes
Automatic temperature compensation (ATC)
Supplied with probe & batteries
Auto-off feature to save battery life.
Specifications
Ranges
Max Resolution
Conductivity:
0 to 1999 S/cm
20 to 199.9 mS/cm
2.00 to 19.99 ms/cm
20.0 to 199.9 ms/cm
0.1S/cm
0.01mS/cm
Temperature:
-5 to 105C
0.1C
Power:
4 x AAA Batteries
Dimensions:
40 x 195 x 36 mm
Weight:
150g
www.accepta.com
Basic Accuracy
1.8F/1C
53
Section 6.9
TRANSPH - pH (also ORP Meter with additional probe)
The pH Meter HP3040 is a portable yet highly accurate pH meter.
Used in all industries, the meter uses the regular BNC connector and accepts a variety of electrodes for special measurement needs.
The meter comes complete in a hard case with calibration buffer solutions
and offers ATC (automatic temperature compensation).
Large LCD with multiple display, displays pH, temperature and time
simultaneously
Multi point calibration - Automatic buffer recognition with built in
standards pH 4, 7 & 10
Custom set available - Manual set to any buffer standard
Up to 5 point calibrations
Capable of reading mV readings with additional probe
Stores/recalls up to 99 data sets with date & time
Supplied with probe & batteries
Stability indicator prompts whenever reading stabilises
Self- Diagnostic with message codes for easy troubleshooting
Auto-off feature to save battery life
Specifications Ranges
Max Resolution
Basic Accuracy
pH
0-14
0.01pH
0.02pH
Temperature:
-5 to 105C
0.1C
0.5C
MV
0.2 mV / 2mV
0.2mV/2 mV
Power:
4 x AAA Batteries
Dimensions:
40 x 195 x 36 mm
Weight:
180g
NOTE: Additional probe required for ORP (mV) measurements - sold separately
www.accepta.com
54
Section 6.10
Borescope/Wireless Inspection Camera - BR200/BR250
Cooling tower fill Pack, Ductwork & Calorifier Monitoring
Each Kit comes complete with:
4 x AA Batteries
USB Cable
AC Adapter
Order Options:
BR200 - 17mm diameter Borescope
BR250 - 9mm diameter Borescope
BR200-EXT - BR200 Borescope Extension Cable
www.accepta.com
55
Section 7.0
Drop Test Kits
www.accepta.com
56
Section 7.1
Drop Test Kits
Acceptas high quality drop test kits are available in a range of parameter specific options to suit most analysis requirements. Each self contained kit is housed in its own rugged case and comes complete with
titration bottle, 65ml reagents, tablets or powders; a crushing rod (if required) and an easy to follow waterproof instruction manual.
Each drop test kit or replacement reagent pack includes reagents
necessary to perform between 100 and 200 tests.
Replacement reagents are available, refer to back of catalogue.
Parameter
Range
Order Code
Acid Strength
0-25%
Drp19079
Dt1025
Str6022
Acidity
50-20,000
Drp19001
PA1 (65ml)
Dt1001
ACD2 (65ml)
Dt1002
ACD3 (65ml)
Dt1003
Alkalinity P
5-2400
Drp19002
PA1 (65ml)
Dt1001
PA2/TA2 (65ml)
Dt1005
TA3 (65ml)
Dt1006
Alkalinity M
5-2400
Drp19003
PA2/TA2 (65ml)
Dt1005
TA3 (65ml)
Dt1006
TA4 (65ml)
Dt1004
Alkalinity OH
5-2400
Drp19004
PA1 (65ml)
Dt1001
PA2/TA2 (65ml)
Dt1005
PA3 (65ml)
Dt1007
TA3 (65ml)
Dt1006
Alkalinity P, M & OH
5-2400
Drp19005
PA1 (65ml)
Dt1001
PA2/TA2 (65ml)
Dt1005
PA3 (65ml)
Dt1007
TA3 (65ml)
Dt1006
TA4 (65ml)
Dt1004
Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.
www.accepta.com
57
Section 7.1
Drop Test Kits (continued)
Parameter
Range
Order Code
5-2000
Drp19006
P1/M (50ml)
Dt1012
P2/3 (65ml)
Dt1013
P9 (65ml)
Dt1014
P10 (65ml)
Dt1015
Bromine Total
0-20
Drp19007
TBR1 (65ml)
Dt1016
TBR2 (65ml)
Dt1017
Carbohydarzide
5-50
Drp19074
CZ1 (65ml)
Dt1652
CZ2 (65ml)
Dt1653
Carbon Dioxide
10-300
Drp19073
PA1 (65ml)
Dt1001
CDX2 (65ml)
Dt1646
10-240
Drp19053
FC1 (65ml)
Dt1018
FC2 (65ml)
Dt1019
FC3 (65ml)
Dt1020
10-240
Drp19008
CT2 (65ml)
Dt1022
Dt1074
Chloride LR & HR
0-3000
Drp19009
BC1/CC1 (65ml)
Dt1023
BC2 (65ml)
Dt1024
CC2 (65ml)
Dt1024
0-300
Drp19010
FCL1 (65ml)
Dt1027
FCL2 (65ml)
Dt1028
FCL3 (65ml)
Dt1029
0.05-1.0
Drp19072
CD4 (40g)
Dt1077
CD5 (40g)
Dt1292
CD6 (20g)
Dt1293
CD7 (65ml)
Dt1114
Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.
www.accepta.com
58
Section 7.1
Drop Test Kits (continued)
Parameter
Range
Order Code
0-12
Drp19011
CD01 (65ml)
Dt1036
CD02A (65ml)
Dt1122
Chlorine Dioxide LR
0-24
Drp19012
CD01 (65ml)
Dt1036
CD02 (65ml)
Dt1037
CD02A (65ml)
Dt1122
0-600
Drp19013
CD01 (65ml)
Dt1036
CD02 (65ml)
Dt1037
CD02A (65ml)
Dt1122
CD03 (65ml)
Dt1038
Hardness Stop/Go
0-4
Dt1129
0-20
Drp19014S
Drp19014T
Dt1121
5-1200
Drp19015
CH2 (65ml)
Dt1043
CH1P (20g)
Dt1050
H/TH4/CH3 (65ml)
Dt1049
TH3 (65ml)
Dt1044
Hardness Total
5-1200
Drp19016
TH3 (65ml)
Dt1044
TH2 (65ml
Dt1046
TH5 (65ml)
Dt1047
H/TH4/CH4
Dt1049
5-1200
Drp19043
CH2 (65ml)
Dt1043
TH2 (65ml
Dt1046
CH1P (20g)
Dt1050
TH5 (65ml)
Dt1047
H/TH4/CH3 (65ml)
Dt1049
TH3 (65ml)
Dt1044
Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.
www.accepta.com
59
Section 7.1
Drop Test Kits (continued)
Parameter
Range
Order Code
Hydrogen Peroxide LR
1-100
Drp19051
HP1 (65ml)
Dt1051
HP3 (65ml)
Dt1053
Hydrogen Peroxide HR
10-5000
Drp19017
HP1 (65ml)
Dt1051
HP2 (65ml)
Dt1052
5-5000
Drp19054
HP1 (65ml)
Dt1051
HP2 (65ml)
Dt1052
HP3 (65ml)
Dt1053
Hypochlorite (Sodium)
0-15%
Drp19060
CL1P (20g)
Dt1030
CL2A (50pk)
Dt1031
CL5 (65ml)
Dt1035
CL2B (10g)
Dt1032
Iron VHR
50-6000
Drp19033
HFE1 (65ml)
Dt1055
HFE2 (65ml)
Dt1056
HFE3 (20g)
Dt1057
HFE4 (65ml)
Dt1058
Molybdate LR
0-50
Drp19018
MB1 (65ml)
Dt1063
MB2 (5g)
Dt1064
MB3 (65ml)
Dt1065
Nitrite
10-2000
Drp19020
N1 (65ml)
Dt1072
N2 (65ml)
Dt1073
Peracetic Acid
10-6000
Drp19045
CL2A (50pk)
Dt1031
CL2B (10g)
Dt1032
HP1 (65ml)
Dt1051
CL7 (65ml)
Dt1054
pH
4-12
Universal pH Indicator
Drp19022
Dt1164
Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.
www.accepta.com
60
Section 7.1
Drop Test Kits (continued)
Parameter
Range
Order Code
0-20
Drp19023
Dt1074
P1/4L (65ml)
Dt1260
P5 (65ml)
Dt1075
0-20
Drp19059
P1/2 (65ml)
Dt1514
P3 (65ml)
Dt1080
P4 Tablets (100pk) or
Dt1080
P4L (65ml
Dt1291
P5 (65ml)
Dt1075
Phosphonate (PBTC)
0-50
Drp19032
PO1 (65ml)
Dt1351
PO2 (65ml)
Dt1352
PO3 (65ml)
Dt1353
0-20
Drp19025
A1 (65ml)
Dt1082
A2 (65ml)
Dt1083
A3 (100ml)
Dt1087
A4 (65ml)
Dt1084
A5 (65ml)
Dt1085
A6 (65ml)
Dt1086
Eq5044
Eq5061
0-20
Drp19026
P1/M (50ml)
Dt1012
P2/3 (65ml)
Dt1013
P4/2 (65ml)
Dt1088
QAC (cationic)
0-1000
Drp19027
QA1 (65ml)
Dt1089
QA2 (65ml)
Dt1090
QA3 (65ml
Dt1091
Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.
www.accepta.com
61
Section 7.1
Drop Test Kits (continued)
Parameter
Range
Order Code
Sulphite
5-300
Drp19028
S1 (40g)
Dt1092
S2 (65ml)
Dt1093
Silver
0-60
Drp19080
Dt1727
Dt1728
Tannin
5-200
Drp19029
TN1 (40g)
Dt1094
TN2 (65ml)
Dt1095
Total Oxidant
0.02-6.0
Drp19030
TO1 (65ml)
Dt1213
TO2 (40g)
Dt1214
TO3 (40g)
Dt1215
TO4 (65ml)
Dt1216
Zinc
0-5
Drp19031
Z1 (65ml)
Dt1096
Z4T (50pk)
Dt1101
Z5 (65ml)
Dt1097
Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.
www.accepta.com
62
Section 8.0
MiniKits
www.accepta.com
63
Section 8.1
MiniKits
Acceptas high quality MiniKits are available in a range of parameter
specific options to suit most analysis requirements.
Each self contained kit is housed in its own rugged case and comes
complete with 30ml reagents, tablets or powders; a test bottle and easy
to follow waterproof instructions. Each kit will perform between 30 and
50 tests.
Additional parameters and replacement reagents are also available,
please refer to Replacement Reagents section.
Parameter
Range
Order Code
Acidity
5-6000
Min41001
PA1 (30ml)
Dt1001
ACD3 (30ml)
Dt1003
Alkalinity P
5-2000
Min41002
PA1 (30ml)
Dt1001
TA3 (30ml)
Dt1006
Alkalinity M
5-2000
Min41003
TA3 (30ml)
Dt1006
TA4 (30ml)
Dt1004
Alkalinity OH
5-2000
Min41004
PA1 (30ml)
Dt1001
PA3 (30ml)
Dt1007
TA3 (30ml)
Dt1006
Bromine Total
0-20
Min41005
TBR1 (30ml)
Dt1016
TBR2 (30ml)
Dt1017
Chelant Total
0-240
Min41006
P1/4L (30ml)
Dt1260
CT2 (30ml)
Dt1022
Chloride LR
5-200
Min41007
BC1/CC1 (30ml)
Dt1023
CC2 (30ml)
Dt1024
Chloride HR
100-3000
Min41008
BC1/CC1 (30ml)
Dt1023
BC2 (30ml)
Dt1026
Chlorine LR
2-30
Min41009
FCL1 (30ml)
Dt1027
FCL2 (30ml)
Dt1028
Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.
www.accepta.com
64
Section 8.1
MiniKits (continued)
Parameter
Range
Order Code
Hardness Calcium
10-1200
Min41012
CH2 (30ml)
Dt1043
H/TH4/CH3 (30ml)
Dt1049
CH1P (10g)
Dt1050
Hardness Total
10-1200
Min41013
TH2 (30ml)
Dt1046
H/TH4/CH3 (30ml)
Dt1049
TH5 (30ml)
Dt1047
Hydrogen Peroxide
10-5000
Min41022
HP1 (30ml)
Dt1051
HP2 (30ml)
Dt1052
Molybdate
0-500
Min41027
MLB1 (30ml)
Dt1440
MLB2 (30ml)
Dt1441
Nitrite
0-2000
Min41014
N1 (30ml)
Dt1072
N2 (30ml)
Dt1073
pH
0-14
Min41016
Dt1164
0-20
Min41017
P1/4L (30ml)
Dt1260
P5 (30ml)
Dt1075
Sulphite
5-200
Min41018
S1 (20g)
Dt1092
S2 (30ml)
Dt1093
Tannin
10-300
Min41019
TN1 (20g)
Dt1094
TN2 (30ml)
Dt1095
QAC Cationics
0-1000
Min41020
QA1 (30ml)
Dt1089
QA2 (30ml)
Dt1090
QA3 (30ml)
Dt1091
Zinc
0-2
Min41021
Z1 (30ml)
Dt1096
Z4T (30pk)
Dt1101
Z5 (30ml)
Dt1097
Individual Replacement Components & complete Replacement Packs are available for each
of the above parameters.
www.accepta.com
65
Section 9.0
Comparator Test Kits
www.accepta.com
66
Section 9.1
Comparator Test Kits
Acceptas high quality comparator test kits are available in a range
of parameter specific options to suit most analysis requirements.
Each self contained kit is housed in its own rugged case and comes
complete with a high quality plastic comparator, comparator disk,
reagents, liquids, tablets or powders; 2 x 10ml plastic cells, a tablet
crusher (if required) and an easy to follow waterproof instructions.
Each comparator test kit or replacement reagent pack includes
reagents necessary to perform between 50 and 100 parameter
specific tests.
Parameter
Range
Order Code
Aluminium
0-0.3
Com81001
Aluminium Disk
256200
Dt1147
Dt1148
Amine
0-15
Com81060
Amine Disk
255005
Dt1643
Dt1644
Dt1645
Ammonia
0-1
Com81002
Ammonia Disk
256210
Dt1245
Dt1244
Bromine
0-5
Com81003
Bromine Disk
256280
Dt1106
Dt1295
Bromine (Liquid)
0-5
Com81003L
Bromine Disk
256280
Dt1505
Dt1506
Dt1295
Carbohydrazide LR
0-0.65
Com81049
Carbohydrazide LR Disc
255011
Dt1654
Dt1741
Individual Replacement Components & complete Replacement Packs are available for each
of the above parameters.
www.accepta.com
67
Section 9.1
Comparator Test Kits (continued)
Parameter
Range
Order Code
Chlorine VLR
0-1
Com81004
256010
Dt1106
Dt1107
0-1
Com81004L
256010
Dt1505
Dt1506
Dt1507
0-4
Com81005
Chlorine LR Disc
256020
Dt1106
Dt1107
Chlorine LR (Liquid)
0-4
Com81005L
Chlorine LR Disc
256020
Dt1505
Dt1506
Dt1507
Chlorine HR (Total)
10-300
Com81006
Chlorine HR Disc
256030
Dt1179
Dt1180
Chlorine LR & HR
0-4/10-300
Com81028
Chlorine LR Disc
256020
Chlorine HR Disc
256030
Dt1106
Dt1107
Dt1179
Dt1180
Chlorine Dioxide
0-2
Com81044
256331
Dt1106
Dt1146
Individual Replacement Components & complete Replacement Packs are available for each
of the above parameters.
www.accepta.com
68
Section 9.1
Comparator Test Kits (continued)
Parameter
Range
Order Code
0-2
Com81044LT
256331
Dt1505
Dt1506
Dt1507
Dt1525
Dt1670
Dt1671
Copper LR (Free)
0-1
Com81008
Copper LR Disc
256230
Dt1149
0-5
Com81010
Copper HR Disc
256430
Dt1240
Dt1239
0-5
Com81034
Copper LR Disc
256230
Copper HR Disc
256430
Dt1149
Dt1240
Dt1239
DEHA
0-0.5
Com81011
DEHA Disc
256370
Dt1739
Dt1166
Hydrogen Peroxide
0-100
Com81053
255040
Dt10672
Dt1673
Iron LR
0-1
Com81012
Iron LR Disc
256220
FE5 (65ml)
Dt1110
* For accurate soluble Iron determination, filtration is required with 0.45 micron filter papers,
filtration pack is available to order separately.
Individual replacement components & Complete Replacement Packs are available for each of
the above parameters
www.accepta.com
69
Section 9.1
Comparator Test Kits (continued)
Parameter
Range
Order Code
Iron LR (Total)
0-1
Com81012T
Iron LR Disc
256220
FE5 (65ml)
Dt1110
Dt1155
0-1
Com81012F
Iron LR Disc
256220
FE5 (65ml)
Dt1110
Dt1155
Eq5044
Eq5061
Iron MR
0.5-5
Com81056
Iron MR Disk
255050
FE9 (65ml)
Dt1723
* For accurate soluble Iron determination, filtration is required with 0.45 micron filter papers,
filtration pack is available to order separately.
Iron MR (Total)
0.5-5
Com81056T
Iron MR Disc
255050
FE9 (65ml)
Dt1723
Dt1155
0.5-5
Com81056F
Iron MR Disc
255050
FE9 (65ml)
Dt1723
Dt1155
Eq5044
Eq5061
Iron HR
0.5-10
Com81013
Iron HR Disc
256320
FE10 (65ml)
Dt1247
* For accurate soluble Iron determination, filtration is required with 0.45 micron filter papers,
filtration pack is available to order separately.
Iron HR (Total)
0.5-10
Com81013LT
Iron HR Disc
256320
FE10 (65ml)
Dt1247
Dt1155
Individual replacement components & Complete Replacement Packs are available for each of
the above parameters
www.accepta.com
70
Section 9.1
Comparator Test Kits (continued)
Parameter
Range
Order Code
0.5-10
Com81040
Iron HR Disc
256320
FE10 (65ml)
Dt1247
Dt1155
Eq5044
Eq5061
0-1/0.5-10
Com81027F
Iron LR Disc
256220
Iron HR Disc
256320
FE5 (65ml)
Dt1110
FE10 (65ml)
Dt1247
Dt1155
Eq5044
Eq5061
Molybdate
0-100
Com81016
Molybdate Disc
245290
Dt1127
Molybdate VHR
0-500
Com81038
245295
Dt1127
Nitrate HR
10-100
Com81018
Nitrate HR Disc
255060
Dt1748
Ozone
0-1
Com81020
256275
Dt1146
Dt1248
pH
4-10
Com81021
pH Universal Disc
256130
Dt1164
Phosphate LR
0-4
Com81022
Phosphate LR Disc
256240
Dt1236
Dt1237
Individual replacement components & Complete Replacement Packs are available for each of
the above parameters
www.accepta.com
71
Section 9.1
Comparator Test Kits (continued)
Parameter
Range
Order Code
Phosphate HR
0-80
Com81023/Com81023L
Phosphate HR Disc
256250
PB1 (65ml)
Dt1111
PB2 (65ml) or
Dt1112
Dt1163
0-80
Com81023TF
Phosphate HR Disc
256250
Dt1163
Eq5044
Eq5048
0-80
Com81023LF
Phosphate HR Disc
256250
PB1 (65ml)
Dt1111
PB2 (65ml)
Dt1112
Eq5044
Eq5048
Silica LR
0.25-4
Com81025P
Silica LR Disc
256350
Dt1233
Dt1234
Dt1235
Silica HR
0-100
Com81050
Silica HR Disc
256351
Dt1735
Dt1736
Dt1737
0-20
Com81066
Tannin Disc
256090
Dt1181
Dt1249
Zinc
0-1
Com81026
Zinc LR Disc
256340
Dt1149
Dt1205
Dt1206
Individual replacement components & Complete Replacement Packs are available for each of
the above parameters
www.accepta.com
72
Section 10.0
Titration Tests
www.accepta.com
73
Section 10.1
Titration Tests
The Brand Titration Gun has been designed to allow very
accurate testing of key parameters important in the chemical
treatment programme.
The titration gun uses a special syringe fixed to a 3 way valve
that has the titration dispensing tube and a screw connection
for the 20ml titration cartridge.
The Titration Gun has 5 settings allowing you to change the
amount of titrant you put in to the sample, giving you greater
accuracy in the results you obtain.
Parameter
Range
Alkalinity P, M & OH
0-2000
Order Code
Crt91002
PA1 (65ml)
Dt1001
TA4 (65ml)
Dt1004
PA3 (65ml)
Dt1007
Chloride
0-2000
Crt91003
BC1/CC1 (65ml)
Dt1023
P3 (65ml)
Dt1080
0-2000
Crt91007
CH2 (65ml)
Dt1043
TH2 (65ml)
Dt1046
TH5 (65ml)
Dt1047
CH1P (20g)
Dt1050
Nitrite
0-2000
Crt91009
N1 (65ml)
Dt1072
Dt1155
Phosphonate
0-50
Crt91004
P1/2 (65ml)
Dt1514
P3 (65ml)
Dt1080
P4L (65ml)
Dt1291
www.accepta.com
74
Section 10.1
Titration Tests (continued)
Parameter
Range
Sulphite
0-150
Order Code
Crt91005
S1 (40g)
Dt1092
Zinc
0-10
Crt91008
Z1 (65ml)
Dt1096
Z4T (50pk)
Dt1101
Eq5022
Individual replacement components & Complete Replacement Packs are available for each of
the above parameters.
www.accepta.com
75
Section 11.0
Test Strips
www.accepta.com
76
Section 11.1
Test Strips
Test papers and strips are used for semi-quantitative determinations of
ions and chemical substances.
They provide the information whether a given component is present at or
above the defined limit of detection. All of our Test Strips come in a
plastic container holding either 25, 50 or 100 individual tests.
The indicator pads on pH strips are non bleed therefore the colour
change remains far longer and readable until the pad is dry.
The strips have a long shelf life and are easy to use.
Parameter
Range
Scale
Code
Ammonia
0-5
0, 0.2, 1, 2, 5
(25 strips per pack)
Str6001
Chlorine Free
0-6
Str6004
Chlorine Total
0-10
Str6005
0-200
Str6006
Chlorine Dioxide LR
0-1.6
Str6007
Chlorine Dioxide HR
0-100
Str6008
Copper
0-2
Str6009
Hardness, Total
0-1000
Str6010
Hardness, Total
0-500
Str6011
Hydrogen Peroxide LR
0-100
Str6012
Hydrogen Peroxide HR
0-400
Str6013
Hydrogen Peroxide HR
0 - 1000
Str6015
Yes/No
Str6035
Peracetic Acid
0-500
Str6057
Str6019
Pack of 3 x 5m reels
Str6020
Potassium
Iodide Refill
www.accepta.com
77
Section 11.1
Test Strips (continued)
Parameter
Range
Scale
Code
Potassium Iodide
Starch
5-100
Str6021
pH
0-6
0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0,
5.5, 6.0 (100 strips per pack)
Str6039
pH
0-14
Str6022
pH
6-10
6.0, 6.4, 6.7, 7.0, 7.3, 7.6, 7.9, 8.2, 8.4, 8.6,
8.8, 9.1, 9.5, 10.0 (100 strips per pack)
Str6032
pH
7-10
Str6026
pH
7-14
Str6027
pH
4.5-10
Str6028
www.accepta.com
78
Section 12.0
Bacteria Testing
www.accepta.com
79
Section 12.1
Oxidising Biocide Test Kits
Acceptas range of oxidising biocide test kits use the new revolutionary Extech Chlorine Meter, which measures by selective ion
electrometry. The Extech Chlorine Meters are unaffected by
colour, turbidity or organic pollutants.
Each kit includes an Extech CL200 Meter, applicable reagents, test
container and detailed instructions. Each kit will carry out between
100 and 300 tests.
With each parameter you have the option of adding in the pH
probe to be used with the Chlorine Meter allowing for the easy
measurement of pH.
Parameter
Range
Order Code
0-10
Ox68003
CL200
Dt1137
Dt1135
Dt1136
0-10
Ox68005
CL200
Dt1137
Dt1135
Dt1136
Dt1138
Dt1139
0-10
Ox68006
CL200
Dt1137
Dt1135
Dt1136
Dt1138
Dt1139
Extech pH Probe
Eq5039
Dt1118
Dt1161
Note: Ox68003 test kit can be used for determining bromine level as a factor of the detected chlorine
level.
Individual replacement components & complete replacement packs are available for each of
the above parameters.
www.accepta.com
80
Section 12.2
Non-Oxidising Biocide Test Kits
Measuring non oxidising biocides is crucial in ensuring that the
biocide in use is not over or under dosed and these non oxidising
biocide test kits are ideal for this application.
Each kit contains all the necessary reagents to carry out between
50 and 100 tests and uses either a colour card or drop count to
determine the reserve.
These test kits can be used to determine the level of biocides in
Open & Closed water systems and can be used when dosing
biocides to systems recently pre-commissioned cleaned.
Parameter
Range
Order Code
Isothiazolone
0-7.5
NOx68001
dK1 (30ml)
Dt1254
dK2 (65ml)
Dt1255
dK3 (65ml)
Dt1256
dK4 (65ml)
Dt1257
dK5 (30ml)
Dt1258
THPS
0-20
NOx68003
Dt1162
Dt1204
Dt1021
Dt1207
DBNPA
0-6.8
NOx68005
Dt1106
Dt1107
Dt1572
Glutaraldehyde
12.5-1600
NOx68006
GL1 (5g)
Dt1605
GL2 (65ml)
Dt1606
PA1 (65ml)
Dt1001
Dt1384
Dt1453
Individual Replacement Components & complete Replacement Packs are available for each of
the above parameters.
www.accepta.com
81
Section 12.3
ATP Meters & Swabs
ATP (adenosine triphosphate) is present in all organic material and is the
universal unit of energy used in all living cells.
ATP is produced and/or broken down in metabolic processes in all living
systems. Processes such as photosynthesis in plants, muscle contraction
in humans, respiration in fungi and fermentation in yeast are all driven by
ATP. Therefore, most foods, water and microbial cells will contain some
level of naturally occurring ATP.
The SystemSURE Plus Luminometer (in conjunction with the Aquasnap or
Ultrasnap ATP swabs) uses bioluminescence to detect residual ATP as
an indicator of water quality (Aquasnap) or surface cleanliness
(Ultrasnap).
The presence of ATP indicates the presence of contamination in water
and on surfaces, including food residue, allergens and/or bacteria. This
implies a potential for the support of bacterial growth.
Equipment
Goods
Code
SystemSURE Plus
SSP/1
100 pens for ATP with Extractant included in each pen US202
AQ100
AQ200
www.accepta.com
82
Section 12.4
Dip-slides & Tube Tests
For Aerobic & Anaerobic Bacteria
Delivering simplicity and affordability through
innovation.
A Dip-slide is a means of testing the microbial content of liquids
or surfaces. It consists of a plastic carrier bearing a sterile culture
medium which can be dipped in a liquid or swabbed on a surface
to be sampled. It is then incubated for 48 hours at 30 to allow
microbial growth.
The resulting microbial colonies are estimated by reference to a
comparison chart. If the treatment programme is effective the
Dip-slide count will be consistently low (<103). If a high result is
obtained the test should be repeated and the treatment
programme checked.
Dip-slides/Tube Tests are supplied in boxes of 10 and come with
instructions to determine the activity of aerobic & anaerobic
bacteria.
The Tube Tests monitor two types of anaerobic bacteria, namely
SRB (Sulphate reducing) & NRB (Nitrite reducing) bacteria found
in closed water systems and are incubated at 35 for 5 days.
Part Code:
Ds84001
TTC/TTC
Ds84002
TTC/MALT
Ds84003
TTC/ROSE
Ds84004
TTC/MAC
TVC/Coliforms &
Ps.aeruginosa
Ds84005
Ds84006
CET/MAC
Ps.aeruginosa
& Enterobacteriaceae
Ds84007
TTC/PDM
Ds84008
Ds84009
www.accepta.com
83
Section 12.5
Incubators
We have a range of high quality incubators designed to suit most applications from site based to
highly portable units. Apart from the factory pre-set Incubator2 all of our incubators have a temperature gauge which allows easy temperature adjustment and monitoring.
The Incubator8P and Incubator45 incubators come complete with 12v car lead.
Note: To use the Incubator2 & Incubator20 in a car an additional cable is required which can be purchased on request.
Incubator2 Order
Code: Eq5057
Incubator8 - 8 Slide
Incubator8P - 8 Slide
Order Code: Eq5055
Incubator18 - 18 Slide
Order Code: Eq5059
Incubator20 - 20 Slide
Order Code: Eq5052
Incubator45 - 45 Slide
Order Code: Eq5093
www.accepta.com
84
Section 12.6
Universal Rapid Legionella Test Kit
UNIVERSAL RAPID LEGIONELLA KIT (RLeg60050)
Acceptas Universal Rapid Legionella Test Kit is a breakthrough in technology for the on site rapid
detection of legionella pneumophila serogroup 1. The kit uses an immunochromatographic assay to
detect within 30 minutes the presence of cell surface antigens from Legionella pneumophila
serogroup 1 (SG1).
The presence of the antigen in the water causes the test line to turn red in colour. A control line
is included which should always turn red if the test has been performed correctly. As the kit is
fully portable it can be used in any water system such as cooling towers, water services, spas,
pools, showers & sprinklers.
Our Universal Rapid Legionella Test Kit can detect with high sensitivity to 100 cfu/l if Legionella
pneumophila SG1 is present in water within 30 minutes and is ideal when access to laboratories is
impractical or speed is imperative.
Filter
Recover
Description
No. Tests
Code
Application
RLeg60050
RLeg60050F
www.accepta.com
85
Section 12.7
Dipslide Comparator App
For use with Accepta Dip-slides
Acceptas app is available on the Apple and Android
storesfree, and will allow the recording with photographic evidence of dip-slides taken on customer
sites.
Simple to use:
The app provides a simple but effective method of
photographing a dip-slide and then displaying it
adjacent to media specific quantification palettes
which move by finger swipe to allow the operator to
make a direct comparison.
The photograph of the compared dip-slide can then
be e-mailed to one or more e-mail addresses for
easy electronic storage.
Graphs can be viewed of historical results and can
even be emailed to clients.
www.accepta.com
86
Section 13.0
Corrosion Coupon Services
Corrosion Coupons
Coupon Weighing
Images are for illustration purposes only and may differ from goods supplied
www.accepta.com
87
Section 13.1
Corrosion Coupons & Test Racks
Most corrosion monitoring/testing in water systems is carried out with the
use of corrosion coupons installed in purpose built corrosion test racks.
The actual metals used for monitoring are most commonly mild steel and
copper with copper the next most widely used.
The corrosion coupons used in field testing are generally 4x
manufactured to fit in standard corrosion test racks. The ASTM D-2688
standard, entitled Corrosivity of Water in the absence of Heat Transfer
(Weight Loss Methods) gives much useful information regarding the
corrosion testing of water.
Corrosion test racks (by-pass rigs) are designed to permit easy and
inexpensive monitoring of corrosion within water systems. Part of the
water is diverted from the main flow into the By-Pass rig where it passes
over test coupons and is then returned to the system. The test coupons
can be removed from the rack without the need to close down the
system.
Corrosion Coupon Specification
4 x x 20 gauge
Materials
Details
Code
Mild Steel
Cc001
Copper
Cc002
Stainless Steel
Cc003
Aluminium
1200
Cc004
Brass
Cc005
Cc006
Cr001
Cr006
Cr004
Cr002
Coupon Weighing
Cw1008
www.accepta.com
88
Section 14.0
PrimeLab (Single or Multi Range) Photometer
www.accepta.com
89
Section 14.1
PrimeLab (Single or Multi Range ) Photometer
(Worlds first expandable photometer)
The PrimeLab Photometer is an easy to use, portable photometer that offers extensive testing
capabilities on a wide range of parameters and systems.
The PrimeLab Photometer tests for all major water constituents with over 80 available
parameter methods (future parameter developments available).
PrimeLab is ready-to-use straight out of the box.
PrimeLab can be purchased as a single parameter unit (i.e. for single range/ClO2) but
can easily be expanded to unlock extra parameters at any time in the future.
All PrimeLab methods are pre-programmed for ease of use.
PrimeLab is Bluetooth enabled for easy communication with laptops or computers.
PrimeLab can store up to 100 test results at any one time (on a rolling sequence).
PrimeLab can hold up to 20 site/system IDs at any one time and test results can be
stored directly against these IDs (IDs are changeable as required).
Powerful, yet easy-to-use software allows report generation and trending of results.
PrimeLab uses photometer grade reagents.
PrimeLab offers a one-time blank per sample, saving significant on-site testing time.
Results are displayed directly in units of concentration, typically mg/l or ppm. In many
methods, concentration in alternate chemical forms is also available. For example,
phosphate readings are available as P, PO4 and P2O5. Displayed results can be
changed from one form to the next by using the UP and DOWN scroll arrows on the
display.
4 x AAA batteries provide self-contained power for field testing. A multi voltage mains
adapter is supplied as standard.
www.accepta.com
90
Section 14.1
Electronic Photometer - PrimeLab (continued)
The PrimeLab 1.0 Multitest is the first truly expandable photometer of its kind. The PrimeLab can be
initially purchased as a single range photometer but can at any time in the future be expanded to
accommodate as many additional parameters as required. This allows the user to customise the
PrimeLab for their individual requirements. Small and handy but powerful due to the JENCOLOR
Multi-Colour Sensor. The PrimeLab includes an inbuilt Bluetooth module which allows wireless
connection to your computer to access the powerful PrimeLab Desktop Assistant software package.
The PrimeLab photometer can be supplied in a range of different sized rugged cases with the size
dependent on the number of parameters, reagents & accessories that you require.
Specifications
Spectral Bandwidth:
PC-Connection:
Calibration:
One-Time-Zero:
Internal Memory:
Datum:
Auto-Off:
Menu:
Power:
Display:
Languages:
Environment:
IP Classification:
Dimensions:
Weight:
NOTE: Alternative single and multi range photometers are available from Accepta, information available on request.
www.accepta.com
91
Section 14.2
PrimeLab Parameters & Reagents
PrimeLab Photometer
Plp1001
c/w - Medium Plastic Case with Foam, Stirring Rod, 10ml Luer Lock Syringe, Cell Cleaning Brush
4 x 10ml Glass Cells, Light Shield, Bluetooth Dongle, Charger & Manual (No Parameter)
ID
Parameter
Range
PID001
Active Oxygen
0.00-40 ppm
Alkalinity M
Plr1158/50
5-200 ppm
Alkalinity P
Plr1144/50
5-300 ppm
PID002
PID003
PID007
PID008
PID063
PID009
Aluminium
Plr1159/50
0-0.3 ppm
Plr1156/50
Plr1157/50
Ammonia
0-1 ppm
Plr1195/50
Plr1196/50
Ammonia
TBC
PL Ammonia 1 (40g)
TBC
PL Ammonia 2 (40g)
TBC
Boron
0-2 ppm
Plr1206/50
Plr1207/50
Bromine
0-18 ppm
Plr1141/50
Plr1143/50
Bromine
0-18 ppm
PL DPD 1 A (30ml)
Plr1102
PL DPD 1 B (30ml)
Plr1103
Plr1108
Calcium Hardness
50-1000 ppm
PID071
Order Code
Calcium Hardness
Plr1146/50
0-500 ppm
Plr1148/50
Plr1149/50
Carbohydrazide
0-1.3 ppm
Plr1112
Plr1113
www.accepta.com
92
Section 14.2
PrimeLab Parameters & Reagents (continued)
ID
Parameter
Range
PID095
Chloramines
0-8 ppm
PID010
PID011
PID012
PID014
PID015
PID016
PID064
Order Code
Plr1141/50
Plr1213/50
Plr1142/50
Chloride
0-5-25 ppm
Plr1154/50
Plr1155/50
Chlorine
0-8 ppm
Plr1141/50
Plr1143/50
Chlorine
0-8 ppm
PL DPD 1 A (30ml)
Plr1102
PL DPD 1 B (30ml)
Plr1103
PL DPD 3 C (30ml)
Plr1104
Chlorine
5-200 ppm
Plr1164/50
Plr1165/50
Chlorine
0-200 ppm
PL Chlorine HR 1 (30ml)
Plr1109
PL Chlorine HR 2 (30ml)
Plr1110
Chlorine Dioxide
0-15 ppm
Plr1141/50
Plr1143/50
Chlorine Dioxide
0-15 ppm
PL DPD 1 A (30ml)
Plr1102
PL DPD 1 B (30ml)
Plr1103
Plr1106
+ Total Oxidant
PID106
Plr1105
Plr1107
Chlorite
0-8 ppm
PL DPD 1 A (30ml)
Plr1102
PL DPD 1 B (30ml)
Plr1103
Plr1106
Plr1105
Plr1107
www.accepta.com
93
Section 14.2
PrimeLab Parameters & Reagents (continued)
ID
Parameter
Range
PID094
Chromium
0-2.2 ppm
PID103
PID079
Plr1210/50
Plr1211/50
Chromium
0-1 ppm
PL Chromate 1 (10g)
Plr1188
PL Chromate 2 (65ml)
Plr1189
COD LR
0-150 ppm
Plr1218
COD MR
0-1500 ppm
Plr1219
COD HR
0-15000 ppm
Order Code
Plr1220
Colour
0-500 ppm
No Reagents Required
PID018
PID019
Copper
0.05-5 ppm
Plr1166/50
Plr1168/50
Copper
0-5 ppm
PL Copper 1 (20g)
PID020
Plr1111
Cyanuric Acid
2-160 ppm
PID082
PID021
PID070
PID072
DBNPA
Plr1145/50
0-13 ppm
PL DPD 1 A (30ml)
Plr1102
PL DPD 1 B (30ml)
Plr1103
PL DPD 3 C (30ml)
Plr1104
DBNPA
0-13 ppm
Plr1141/50
Plr1142/50
DEHA
20-1000 ppb
Plr1112
Plr1113
Erythrobic Acid
0-3.5 ppm
Plr1112
Plr1113
Fluoride
0-2ppm
PL Fluoride 1 (65ml)
Plr1114
PL Fluoride 2 (65ml)
Plr1175
www.accepta.com
94
Section 14.2
PrimeLab Parameters & Reagents (continued)
ID
Parameter
Range
PID078
Hardness Calcium
0-500ppm
PID009
Plr1148/50
Plr1149/50
Hardness Calcium HR
50-1000 ppm
Hardness Total HR
Plr1146/50
20-500 ppm
Hardness Total LR
Plr1150/50
2-50 ppm
Hydrazine
Plr1146/50
5-600 ppm
PL Hydrazine 1 (65ml)
PID026
PID024
Plr1115
Hydroquinone
0.2.5 ppm
Plr1112
Plr1113
Hydrogen Peroxide LR
0-3.8ppm
PID025
PID027
Hydrogen Peroxide LR
Plr1214/50
0-3.8 ppm
Plr1152
Plr1153
Hydrogen Peroxide HR
0-200 ppm
Plr1116
Plr1117
Iodine
0-28 ppm
PID028
Order Code
Iodine
Plr1141/50
0-28 ppm
PL DPD 1 A (30ml)
Plr1102
PL DPD 1 B (30ml)
Plr1103
Iron LR
0-1 ppm
Plr1151/50
Iron MR
0-10ppm
PL Iron MR 1 (20g)
Plr1118
www.accepta.com
95
Section 14.2
PrimeLab Parameters & Reagents (continued)
ID
Parameter
Range
PID030
Iron HR
0-30ppm
Order Code
PL Iron HR 1 (65ml)
Plr1119
PL Iron HR 2 (30ml)
Plr1120
Magnesium
0-100ppm
PID104
PID069
PID096
PID032
PID033
Manganese
Plr1212/50
0.2-5ppm
Plr1201/50
Plr1202/50
Manganese
TBC
PL Manganese 1 (65ml)
TBC
PL Manganese 2 (65ml)
TBC
PL Manganese 3 (65ml)
TBC
Methylethylketoxime
0-4.1ppm
Plr1112
Plr1113
Molybdate LR
0-15ppm
Plr1199/50
Plr1200/50
Molybdate
1-100ppm
Plr1162/50
Plr1163/50
Molybdate HR
5-200ppm
PL Molybdate 1 (65ml)
PID099
PID090
PID100
Plr1121
Nickel LR
TBC
PL Nickel LR 1 (50g)
TBC
PL Nickel LR 2 (65ml)
TBC
PL Nickel LR 3 (20g)
TBC
Nickel HR
TBC
TBC
TBC
Nickel HR
0-10 ppm
PL Nickel HR 1 (50ml)
Plr1181
PL Nickel HR 2 (30ml)
Plr1182
PL Nickel HR 3 (30ml)
Plr1183
www.accepta.com
96
Section 14.2
PrimeLab Parameters & Reagents (continued)
ID
Parameter
Range
PID034
Nitrate
TBC
PL Nitrate 1 (50g)
PID035
TBC
Nitrite LR
0-0.5ppm
Nitrite HR
Plr1168/50
5-200ppm
PL Nitrite HR 1 (50g)
PID097
PID101
Plr1184
Nitrite HR
TBC
TBC
TBC
Nitrite HR
0-3000 ppm
PL Nitrite HR 2 (65ml)
PID092
PID037
PID098
PID040
Plr1184
Ozone
0-5.4ppm
PL DPD 1 A (30ml)
Plr1102
PL DPD 1 B (30ml)
Plr1103
PL DPD 3 C (30ml)
Plr1104
Plr1106
Ozone
0-5.4ppm
Plr1141/50
Plr1142/50
Plr1143/50
Phenol
0-5ppm
Plr1215/50
Plr1216/50
Plr1217/50
pH LR
TBC
pH MR
TBC
6.4-8.4
pH MR
Plr1147/50
6.4-8.4
PL pH 6.4-8.4 (30ml)
PID041
Plr1125
pH Universal
5-11
Order Code
pH Universal
Plr1194/50
4-11
PL pH 4-11 (65ml)
Plr1126
www.accepta.com
97
Section 14.2
PrimeLab Parameters & Reagents (continued)
ID
Parameter
Range
PID043
PHMB
TBC
PID045
PID046
Phosphate LR
Order Code
TBC
0-4 ppm
Plr1191/50
Plr1192/50
Phosphate LR
0-4 ppm
PL Phosphate LR 1 (65ml)
Plr1127
PL Phosphate LR 2 (10g)
Plr1128
Phosphate HR
0-80 ppm
Plr1197/50
Plr1198/50
Phosphate HR
0-100 ppm
PL Phosphate HR 1 (65ml)
Plr1129
PL Phosphate HR 2 (65ml)
Plr1130
Phosphonate
0-20 ppm
PL Phosphonate 1 (20g)
Plr1169
PL Phosphonate 2 (20g)
Plr1170
PL Phosphonate 3 (65ml)
Plr1171
PL Phosphonate 4 (20g)
Plr1172
PID048
Polyacrylate
1-30 ppm
PL Polyacrylate 1 (65ml)
Plr1139
PL Polyacrylate 2 (65ml)
Plr1140
Potassium
TBC
PID049
QAC
TBC
TBC
TBC
TBC
Silica LR
0-5 ppm
PL Silica LR 1 (65ml)
Plr1131
PL Silica LR 2 (65ml)
Plr1132
PL Silica LR 3 (40g)
Plr1133
www.accepta.com
98
Section 14.2
PrimeLab Parameters & Reagents (continued)
ID
Parameter
Range
PID050
Silica HR
0-100 ppm
PID051
PID068
PID054
PL Silica HR 1 (20g)
Plr1134
PL Silica HR 2 (60g)
Plr1135
PL Silica HR 3 (10g)
Plr1136
Sodium Hypochlorite
0.2-40%
Plr1164/50
Plr1165/50
Sodium Hypochlorite
0.2-40%
PL Chlorine HR 1 (30ml)
Plr1109
PL Chlorine HR 2 (30ml)
Plr1110
Sulphate
5-100 ppm
Sulphate
Plr1160/50
5-100 ppm
PL Sulphate 1 (10g)
PID052
PID053
Plr1137
Sulphide
TBC
TBC
TBC
Sulphite LR
TBC
PID105
PID082
Order Code
Sulphite HR
TBC
TBC
TBC
PL Sulphite HR 2 (65ml)
TBC
Sulphite HR
5-50 ppm
Plr1203/50
Plr1204/50
Suspended Solids
0-750 ppm
No Reagents Required
PID091
PID058
Tannic Acid
0-20 ppm
PL Tannin 1 (65ml)
Plr1176
PL Tannin 2 (30ml)
Plr1177
Triazole
TBC
PL Triazole 1 (50g)
TBC
UV lamp required
PID059
Turbidity
20-1000FAU
No Reagents Required
www.accepta.com
99
Section 14.2
PrimeLab Parameter & Reagents (continued)
ID
Parameter
Range
PID062
Zinc
0-1ppm
Order Code
Plr1161/50
Plr1190/50
Please Note:
New parameters are being added to the PrimeLab on a regular basis so it is important that you
update your PrimeLab to take full advantage of firmware and software upgrades.
If a parameter you require is not listed and you require multiple photometers, please email our
Technical Department (help@accepta.com) to enquire if the parameter can be added.
www.accepta.com
100
Section 15.0
Temperature Meters
www.accepta.com
101
Section 15.1
Temperature Meters - Pocket Stick Type
The Waterproof pocket Thermometer is pocket size with min/max
recording
Features
www.accepta.com
102
Section 15.2
Temperature Meters - KT102 Dual K Type Thermometer
The Waterproof Type K Thermometer has a large LCD display with 0.3% accuracy.
Specifications:
Temperature (Type K:)
Display Counts:
Basic Accuracy:
Resolution:
Dimensions:
Weight:
www.accepta.com
103
Section 15.3
Temperature Meters - EA10 Dual K Type Thermometer
The Waterproof EA10 Type K Thermometer has a large LCD
display with 0.3% accuracy.
Specifications:
Temperature (Type K:)
Display Counts:
Basic Accuracy:
Resolution:
Dimensions:
Weight:
Power:
www.accepta.com
104
Section 15.4
Temperature Meters - Extech IR with K Type Input
Extech branded IR Thermometer with Type K input has
adjustable High/Low set points with visible and audible alarm and
0.1 resolution.
Features
Applications:
Specifications
Range:
Basic Accuracy:
www.accepta.com
105
Section 16.0
Equipment & Components
www.accepta.com
106
Section 16.1
Equipment & Components
Offering an extensive range of test equipment, parts and replacement components.
All products are available from stock for immediate dispatch.
Description:
Pack:
Code:
Each
Eq5074
Each
Eq5076
Each
Eq5077
Each
Eq5177
Each
Eq5073
Each
Eq5168
Each
Eq5075
Each
Eq5078
Each
Eq5078L
Each
Eq5022
Each
Eq5151
Each
Eq5023
Each
Eq5155
Each
Eq5190
Each
Eq5118
3 Way Valve
Each
Eq5013
Filtration:
Syringe Filter Holder - 25mm
Eq5044
50pk
Eq5048
50pk
Eq5061
Each
Eq5366
100pk
Eq5365
Eq5086
50pk
Eq5181
5pk
Eq5006
Each
Eq5015
Each
Eq5007
Each
Eq5214
Each
Eq5019
Each
Eq5016
Each
Eq5018
Each
Eq5008
www.accepta.com
107
Description:
Pack:
Code:
Each
Eq5012
Each
Eq5002
Each
Eq5011
Each
Eq5083
Each
Eq5033
Each
Eq5064
Each
Eq5082
9v Battery
Each
Eq5131
AA Battery
Each
Eq5128
AAA Battery
Each
Eq5206
CR2032 Battery
Each
Eq5088
SR44 Battery
Each
Eq5158
Batteries:
Eq5029
Eq5029F
Eq5030
Eq5030-2
Eq5028
Eq5028-2
Eq5027
Eq5026DF
Eq5026
Eq5026E
Accessories:
Plastic Comparator
Each
Eq5085
Tablet Crusher
Each
Eq5079
Each
Eq5196
Each
Eq5188
Each
Eq5009
Each
Eq5373
Each
Eq5222
Eq5130
Each
Eq5024
Each
Eq5025
www.accepta.com
108
Section 17.0
Reagents Available
www.accepta.com
109
Section 17.1
Reagents Available
Offering an extensive range of reagents listed by Reagent Name.
All reagents are available from stock for immediate dispatch.
Description:
Pack:
Code:
Each
Dt1103
A1 - Buffer (65ml)
Each
Dt1082
A2 - Precipitant (65ml)
Each
Dt1083
A3 - Solvent (50ml)
Each
Dt1087
A4 - Indicator (65ml)
Each
Dt1084
A5 - HR Titrant (65ml)
Each
Dt1085
A6 - LR Titrant (65ml)
Each
Dt1086
Each
Dt1414
Each
Dt1180
Each
Dt1008
Each
Dt1188
Each
Dt1010
Each
Dt1011
Each
Dt1342-50
Each
Dt1478
Each
Dt1102
Each
Dt1538-50
Each
Dt1535
Each
Dt1147-50
Each
Dt1148-50
Each
Dt1644-65
Each
Dt1643-65
Each
Dt1645-50
Each
Dt1042
Each
Dt1245-50
Each
Dt1244-50
Each
Dt1219
Each
Dt1237
Each
Dt1023
Each
Dt1026
BP1V (65ml)
Each
Dt1479
Each
Dt1494
www.accepta.com
110
Section 17.1
Reagents Available (continued)
Carbohydrazide LR Indicator Solution (65ml)
Each
Dt1741
Each
Dt1654
Each
Dt1259
Each
Dt1024
Each
Dt1036
Each
Dt1037-65
Each
Dt1122
Each
Dt1038
Each
Dt1009
Each
Dt1050
Each
Dt1105
Each
Dt1043
Each
Dt1591-50
Each
Dt1592-50
Each
Dt1510-50
Each
Dt1345
Each
Dt1179
Each
Dt1221-50
Each
Dt1141
Each
Dt1142
Each
Dt1025
Each
Dt1738-20
Each
Dt1240-50
Each
Dt1239-50
Each
Dt1211
Each
Dt1211
Each
Dt1212
Each
Dt1203-50
Each
Dt1149-50
Each
Dt1169
Each
Dt1170
Each
Dt1231
Each
Dt1236
Each
Dt1391-50
Each
Dt1391-52
Each
Dt1391-53
Each
Dt1391-54
Each
Dt1391-55
Each
Dt1246
www.accepta.com
111
Section 17.1
Reagents Available (continued)
dK1 (30ml)
Each
Dt1254
dK2 (65ml)
Each
Dt1255
dK3 (65ml)
Each
Dt1256
dK4 (65ml)
Each
Dt1257
dK5 (30ml)
Each
Dt1258
Each
Dt1671
Each
Dt1443-50
Each
Dt1275
Each
Dt1143
Each
Dt1525-30
Each
Dt1146-50
Each
Dt1392-50
Each
Dt1131-50
Each
Dt1106-50
Each
Dt1107-50
Each
Dt1533-50
Each
Dt1505-30
Each
Dt1506-30
Each
Dt1507-30
Each
Dt1277
Each
Dt1204
Each
Dt1205-50
EX1 (65ml)
Each
Dt1137
EX2 (65ml)
Each
Dt1135
EX3 (65ml)
Each
Dt1136
EX4 (65ml)
Each
Dt1134-65
EX5 (65ml)
Each
Dt1138
EX6 (65ml)
Each
Dt1139
Each
Dt1252
Each
Dt1027
Each
Dt1028
Each
Dt1029
Each
Dt1247
Each
Dt1110
Each
Dt1113
Each
Dt1128
Each
Dt1723
FIR1 (65ml)
Each
Dt1340
FIR2 (65ml)
Each
Dt1341
FIR3 (65ml)
Each
Dt1445-65
www.accepta.com
112
Section 17.1
Reagents Available (continued)
GL1 (5g)
Each
Dt1605
Each
Dt1606
Each
Dt1607
Each
Dt1049
Each
Dt1477
Each
Dt1476
Each
Dt1475
Each
Dt1129
Each
Dt1530-50
Each
Dt1121-50
Each
Dt1055
Each
Dt1056
Each
Dt1057
Each
Dt1058
Each
Dt1051
Each
Dt1052
Each
Dt1053
Each
Dt1468
Each
Dt1413
Each
Dt1230-50
Each
Dt1117-50
Each
Dt1355
M2 - Indicator (65ml)
Each
Dt1356
M3 - LR Titrant (65ml)
Each
Dt1357
Each
Dt1349-50
Each
Dt1350-50
Each
Dt1771
Each
Dt1772
Each
Dt1773
Each
Dt1063
Each
Dt1064
Each
Dt1065
Each
Dt1440
Each
Dt1441
Each
Dt1550
www.accepta.com
113
Section 17.1
Reagents Available (continued)
MO1 - Acidifier (65ml)
Each
Dt1066
Each
Dt1067-20
Each
Dt1067
Each
Dt1068
Each
Dt1069
Each
Dt1070
Each
Dt1071
Each
Dt1732-20
Each
Dt1733-20
Each
Dt1734-20
Each
Dt1127
Each
Dt1115-50
Each
Dt1116-50
Each
Dt1072
Each
Dt1177
Each
Dt1073
Each
Dt1178
Each
Dt1748
Each
Dt1373-50
Each
Dt1536
Each
Dt1537
Each
Dt1151-50
P1 - CL Remover (65ml)
Each
Dt1078
Each
Dt1514-65
Each
Dt1074
Each
Dt1260
Each
Dt1012
P2 - Indicator (65ml)
Each
Dt1079
P3 - pH Adjuster (65ml)
Each
Dt1080
Each
Dt1081-50
Each
Dt1088
P5 - Titrant (65ml)
Each
Dt1075
Each
Dt1001
Each
Dt1005
Each
Dt1007
www.accepta.com
114
Section 17.1
Reagents Available (continued)
PB1 - Phosphate HR No 1 (65ml)
Each
Dt1111
Each
Dt1112
Each
Dt1161-65
Each
Dt1119-65
Each
Dt1118-65
Each
Dt1220-50
Each
Dt1243-50
Each
Dt1250
Each
Dt1616-50
Each
Dt1521-50
Each
Dt1522-50
Each
Dt1163-50
Each
Dt1225
Each
Dt1226
Each
Dt1731-20
Each
Dt1351
Each
Dt1352
Each
Dt1353
Each
Dt1546-50
Each
Dt1469-65
Each
Dt1470
Each
Dt1471
Each
Dt1089
Each
Dt1090
Each
Dt1091
QA4 (65ml)
Each
Dt1157
Each
Dt1158
Each
Dt1338
Each
Dt1336
Each
Dt1339
Each
Dt1222
Each
Dt1238-65
Each
Dt1347-65
Each
Dt1580
Each
Dt1448-65
www.accepta.com
115
Section 17.1
Reagents Available (continued)
Redox Standard 475mV (65ml)
Each
Dt1223-65
Each
Dt1420-65
Each
Dt1092
Each
Dt1093
Each
Dt1735-20
Each
Dt1736-60
Each
Dt1737-10
Each
Dt1195
Each
Dt1201
Each
Dt1156
Each
Dt1233
Each
Dt1234
Each
Dt1235
Each
Dt1540
Each
Dt1541
Each
Dt1217-65
Each
Dt1419-65
Each
Dt1154-65
Each
Dt1109-65
Each
Dt1209-65
Each
Dt1458-65
Each
Dt1153-65
Each
Dt1120-65
Each
Dt1398
Each
Dt1218-65
Each
Dt1232-65
Each
Dt1227
Each
Dt1228
Each
Dt1613
Each
Dt1612
Each
Dt1229
Each
Dt1729
Each
Dt1155
Each
Dt1006
Each
Dt1004
www.accepta.com
116
Section 17.1
Reagents Available (continued)
Tannin No1 T/C Tablets (100B)
Each
Dt1159-100B
Each
Dt1160-250B
Each
Dt1016
Each
Dt1017
Each
Dt1048
Each
Dt1104
Each
Dt1046
Each
Dt1044
Each
Dt1047
Each
Dt1207
Each
Dt1094
Each
Dt1095
TO1 (65ml)
Each
Dt1213
TO2 (40g)
Each
Dt1214
TO3 (40g)
Each
Dt1215
TO4 (65ml)
Each
Dt1216
Each
Dt1593-50
Each
Dt1164
Each
Dt1710-100
Z1 - CL Remover (65ml)
Each
Dt1096
Z2 - Buffer (65ml)
Each
Dt1099
Each
Dt1098
Each
Dt1101
Each
Dt1101
Each
Dt1167
Each
Dt1168
www.accepta.com
117
2. The Contract
2.1 All orders are accepted under these Terms & Conditions
alone.
2.2 These Terms & Conditions exclude any other Terms &
Conditions inconsistent therewith which a buyer might seek to
impose even though such other terms and conditions may be
submitted in a later document and/or purport to exclude or
supersede any Terms & Conditions inconsistent with them or
may be contained in any offer acceptance or counter-offer made
by the Buyer.
2.3 No variations of these Terms & Conditions is permitted
unless expressly accepted by a Director of the Company in
writing.
2.4 All verbal orders must be confirmed to the Company in
writing by email, fax or by post.
3. Cancellation
3.1 No cancellation by the Buyer is permitted except where
expressly agreed by the Company.
3.2 The Buyer will in the event of agreed cancellation by the
Buyer indemnify the Company fully against all expenses incurred
up to the time of such cancellation.
4. Price
4.1 All prices charged are those ruling at the date of acceptance
of the order from the Buyer unless otherwise stated.
4.2 Unless otherwise stated the prices charged are net ex works
exclusive of Value Added Tax.
4.3 The Company reserves the right at any time prior to delivery
of the Goods to adjust the price to take account of any increase
in the cost of raw materials, labour or services, taxes or duties or
any currency fluctuations affecting the cost of imported materials.
5. Terms of Payment
5.1 The Buyer shall make payment net cash with the Buyers
order except where the Company has agreed to open a credit
account. In the case, the Buyer shall make payment net cash
against every invoice from the Company within 30 days of the
date of such invoice.
5.2 Time for payment shall be of the essence.
5.3 The Company reserves the right to charge interest at 2% per
month on all overdue accounts., such interest being deemed to
accrue on a day to day basis from the due date for payment
under clause 5.1.
5.4 The Buyer shall have no right of set off, statutory or otherwise.
5.5 If the Buyer (being a company) has a petition presented for
its winding-up or for an administration order under the Insolvency
Act 1986 or passes a resolution for voluntary winding-up otherwise than for the purpose of a bona fide amalgamation or
reconstruction or compounds with its creditors or has a receiver
appointed of all or any part of its assets or (being an individual)
becomes bankrupt of insolvent or enters into any arrangement
with its creditors of commits a material or serious breach of this
Agreement (and in the case of such a breach being remediable
fails to remedy it within 7 days of receiving notice to do so), he
will be deemed to have repudiated the Contract.
5.6 The Company reserves the right at any time at its discretion
to demand security for payment before continuing with or
delivering any Order.
6. Delivery
6.1 All items quoted for delivery shall be delivered to the Buyers
address or, if different, as specified on the Buyers order.
6.2 The Company shall be responsible for the delivery of Goods
to the delivery address, but the cost of such delivery, packing
and insurance may be charge to the Buyer.
6.3 Time of delivery is not of the essence.
6.4 The Company shall not be liable for any loss whatsoever or
howsoever arising caused by its non-delivery.
6.5 The Company reserves the right to make delivery by instalments and to tender a separate invoice in respect of each
instalment.
6.6 When delivery is to be by instalment or the Company exercises its right to delivery by instalments under clauses 6.5 hereof or
if there be any delay in the delivery of any one or more instalments for whatever reason this will not entitle the Buyer to treat
the contract as repudiated or to damages.
6.7 Deviations in quantity of the Goods delivered (representing
not more than 10 per cent by value) from that stated in the
Buyers ordeal shall not give the Buyer any right to reject the
Goods or to claim damages and the Buyer shall be obliged to
accept and pay at the contract rate for the quantity of the Goods
delivered.
7.4.3 the Company may at any time revoke the power of sale
and use of the Goods by notice to the Buyer if the Buyer is in
default for longer than 14 days in the payment of any sum
whatsoever due to the Company (whether in respect of the
Goods or any other goods supplied at any time by it to the Buyer)
or if the Company has bona fide doubts as to the solvency of the
Buyer);
7.4.4 the Buyers power of sale and use shall automatically
cease if the Buyer has a petition presented for its winding-up or
for an administration order under the Insolvency Act 1986 or
passes a resolution for voluntary winding-up otherwise than for
the purposes of a bona fide amalgamation or reconstruction or
compounds with its creditors or has a receiver appointed of all or
any part of its assets or becomes bankrupt or insolvent or enters
into any arrangements with creditors or takes or suffers any
similar action in consequence of debts or carries out or undergoes any analogous act or proceedings under foreign law;
7.4.5 upon determination of the Buyers power of sale and use
the Buyer shall place any of the Goods, in its possession or under
its control, at the disposal of the Company and the Company shall
be entitled to enter the premises of the Buyer for the purpose of
removing the Goods.
7.5 The Company shall at any time be entitled to appropriate any
payment made by the Buyer in respect of any Goods in settlement of such invoices or accounts in respect of such goods as
the Company may in its absolute discretion think fit notwithstanding any purported appropriated to the contrary by the Buyer.
9. Inspection/Shortage
9.1 The Buyer is under a duty whenever possible to inspect the
Goods on delivery or on collection as the case may be.
9.2 Where the Goods cannot be examined the carriers note or
such other note as appropriate shall be marked not examined.
9.3 The Company shall be under no liability for any damage or
shortages that would be apparent on careful inspection if the
terms of this clause are not complied with and, in any event will
be under no liability if a written complaint is not delivered to the
Company within 10 days of delivery detailing the alleged damage
or shortage.
9.4 In all cases where defects or shortages are complained of the
Company shall be under no liability in respect thereof unless an
opportunity to inspect the Goods is supplied to the Company
before any use is made thereof or any alteration or modification is
made thereto by the Buyer.
9.5 Subject to Clause 9.3 and 9.4, the Company shall make good
and shortage in the Goods and where appropriate replace any
goods damaged in transit as soon as it is reasonable to do so, but
otherwise shall be under no liability whatsoever arising from such
shortage or damage.
10. Warranty
10.1 The Company warrants that it has title to and the unencumbered right to sell the Goods.
10.2 It is the Buyers responsibility to ensure that the Goods are
suitable for the purpose to which that are intended to be used.
10.3 No representation or warranty is given as to the suitability or
fitness of the Goods for any particular purpose and the Buyer
shall satisfy itself in this respect and shall be totally responsible
thereof.
10.4 If the Buyer has any specific requirements for the use of the
Goods the Buyer must notify requirements to the Company in
writing before purchasing the Goods.
10.5 If the Buyer is unsure as to the suitability of any Goods for a
particular purpose it should consult the Company prior to purchase.
10.6 If the Goods are in such a state as would but for this
condition entitle the Buyer to repudiate the contract and/or claim
damages from the Company, the Company reserves the right to
repair or replace the Goods.
15. Notice
Any notice to be given hereunder shall be in writing and shall be
deemed to have been duly given if sent or delivered to the party
concerned at its address specified overleaf or such address as
the party may from time to time notify in writing and shall be
deemed to have been served, if sent by post, 48 hours after
posting.
16. Assignment
Neither the Company nor the Buyer shall assign or transfer or
purport to assign of transfer the contract or the benefits thereof to
any other person without prior written consent of the other.
11. Liability
11.1 Introduction
11.1.1 Nothing in clause 11 shall be deemed to exclude or
restrict the Companys liability for death or personal injury
resulting from the Companys negligence.
11.1..2 Each of the sub-clauses in Clause 11 is to be treated
as separate and independent.
11.2 Exclusion
11.2.1 Clauses 11.2 only covers defects caused by faulty
design, manufacture, materials or workmanship. It does not cover
defects caused by abnormal use, misuse or neglect. It does not
cover faulty design, manufacture materials or workmanship
supplied or undertaken by the Buyer or third parties. In respect of
goods not designed or manufactured by the Company, the
Company only gives such guarantee or warranty to the Buyer as
the Company itself receives.
11.2.2 The Company agrees that if any defect covered by
Clause 11.2 is discovered during the period of twelve months
commencing with the date of dispatch, the Company will either
repair the goods at its own expense or, if it chooses to do so,
replace them.
11.2.3 The Company does not bear responsibility for any
defect arising or introduced by a Buyer in the course of storage or
handling of the products where that Buyer acts as an agent or
distributor of the Companys products. The Buyer should consult
the Company if doubt exists with regard to the appropriate
storage or handling requirements.
11.2.4 The Buyer cannot claim the benefit of this clause
unless:
(1) he informs the Company of the relevant defect in writing within
www.accepta.com
18. Waiver
The rights and remedies of the Company under the contract shall
not be diminished, waived or extinguished by the granting of any
indulgence, forbearance or extension of time by the Company in
asserting or exercising any such rights or remedies.
19. Headings
The headings of these conditions are for convenience only and
shall have no effect on the interpretation thereof.
118
www.accepta.com
119