You are on page 1of 3

FUTEK HID ELECTRONIC -BALLAST

SPECIFICATIONS FOR MODEL: FT-HID 250WDD3P


Designed for heavy duty and high temperature weather use

PARAMETERS FT-HID 250WDD3 P


INPUT:
Rated Voltage 220V

Working Voltage Range 160 ~ 260 Vac

Frequency 50/60 Hz

System Current:
Full Capacity At 220V 1.2A +/- 5 %
Dimming Mode At 220V Lowest: 0.59A +/- 10%

System Circuit Power:


Full Capacity 265W +/- 5 % max
Dimming Mode Customized: Lowest 130W +/- 5 %

Power Factor: >0.99


Full Capacity
Dimming Mode > 0.96

Total Harmonic Distortion:


Full Capacity < 10%
Dimming Mode

OUTPUT:
Lamp Type HPSV 250- Philips Or Osram Or GE or equivalent

Lamp Wattage:
Full Capacity 250W +/- 2%
Dimming Mode Lowest at 106.2W +/- 5 %

Lamp Power Factor > 0.98

Lamp Voltage 100V + or – 5 %

Lamp Current Crest Factor < 1.6

Lamp Operating Frequency Range:


Full Capacity 45 ~ 52 KHz
Dimming Mode 63 ~ 70 KHz

Dimming Level Customized: From 100% to 50%

OPERATING ENVIRONMENT
Ambient Temperature (Ta) -20 ~ +65°C

Housing Temperature (Tc) Max +90°C + or – 10%

PROTECTION FEATURE:
Protection Enable,
No Load Condition
Reset by power reset

Hot Re igniting Time Approx 45~ 60 sec

Re ignition Before Tube Cooled Down Protection Enable,


Reset by power reset

Protection Enable,
Lamp Fault
Reset by power reset

Protected
Over Voltage > 270V ~ 420 Volt Auto connection when power back to normal working range

8 preprogrammed position via 3 DIP Switches according to attach


Dimming options dimming program ( Customized )

100% > 90% >75 % >65% > 50%


Dimming Range

1) Digital To Digital using 3micro-processors for maximum reliability


Dimming Technology 2) DD3 Technology , 5 Dimming steps
3) With Dimming Memory Position recall

Weight 1750 gm + or – 10%

Thermal Over Heat ( Tc > 100C) Protected ( micro processor thermal control 100C + 10C

Over and Under Voltage Protection Power Off “ Protected Under 140V and Over 270V “

Voltage Monitoring processor “GST” * Protected with 5 ~ 15 second Grouping Starting Technology *

Voltage Monitor Technology Delay Time ** 5 ~ 20 Seconds ( At start Mode Only )

STANDARD DESIGN TO COMPLIED:


Safety Standard EN60928

Performance Standard EN60929

EMC Immunity EN61547

Current Harmonic Emission EN61000-3-2

Voltage Flicker EN61000-3-3

RFI EN55015/CISPR 15
*GST : Grouping Start Technology will divide large quantities of Ballast in several groups with 2 seconds delay

Between each of them in order to minimize starting rush Intensity and to optimize supply transformer efficiency.

** Voltage Monitor Technology will protect ballast from Surge Current , bad contacts , non stable Voltage at start

*** Technical data subject to change without notice.