You are on page 1of 14

Professional

solutions
from
professionals

LIGHT COMMERCIAL COMFORT SOLUTIONS

Carrier light commercial solutions are designed to meet the


requirements of a variety of building types and applications.

ENERGY EFFICIENCY

The inverter technology that the systems use offers


considerable advantages in terms of energy savings. The
variable capacity management of the compressor allows
the system to maintain room temperature control and
to ensure minimum energy usage.

EXTENDED RANGE OF SOLUTIONS

Carrier Light Commercial systems, with state-of-the-art


technologies, flexible controls, variety of indoor units, wide
range of capacities and improved installation, bring comfort
and convenience to any light commercial installation.

OPERATIONS & MAINTENANCE

With superior quality and performance, the decision to


partner with Carrier for light commercial solutions is an
easy one. Our independent partners make installing and
maintaining those solutions for optimal performance
simple as well.

Setting
the standard
for performance,
energy efficiency
and sustainability

SINGLE SPLIT SYSTEMS

Inverter Console/Under-Ceiling XPower | 42QZL/38QUS

FEATURES
This console has been designed not only to be slim and stylish
but also to give high performance.
All units can be mounted on walls or under the ceiling.
3D motorised louvers allow air distribution direction according
to individual preferences.
State of the art fans and advanced slimline coil.
Easy installation and maintenance: all internal components can be
easily accessed by removing the grille.
Choice of wired (optional) or wireless controls (standard).

UNIT

REMOTE CONTROL

LIGHT COMMERCIAL COMFORT SOLUTIONS

40

TECHNICAL SPECIFICATIONS*
Model IDU
Model CDU
Nominal
Cooling mode
Capacity
Capacity range (min-max)
Power consumption
EER
SEER
Energy class
Seasonal energy consumption

42QZL018DSA
38QUS018DSA
18.000

42QZL024DSA
38QUS024DSE
24.000

42QZL036DSA
38QUS036DSE
36.000

42QZL048DSA
38QUS048DTE
48.000

42QZL060DSA
38QUS060DTE
60.000

5,2
2,1~5,5
1,84
2,9
5,9
A+
308

6,8
2,5~7,0
2,45
2,8
6,0
A+
397

10,3
5,3~12,0
4,35
2,4
6,0
A+
601

12,2
7,7~14,2
4,20
3,0
/
/
2100

13,0
7,5~15,8
4,70
2,8
/
/
2350

6,8
2,4~7,0
2,20
3,1
3,8
4,6
A
A++
1879
2161

11,5
5,7~14,0
3,20
3,5
3,8
4,9
A
A++
3795
3000

14,5
7,5~18,0
4,80
3,2
/
/
/

17,0
7,4~20,2
5,70
2,9
/
/
/

kWh
kWh

5,4
2,0~6,0
1,65
3,3
3,8
5,1
A
A+++
1511
1235

2400

2850

INDOOR UNIT
Air flow (H/M/L)
Sound power level
Sound pressure level (H/M/L)
Weight (Net)
Dimensions (WxDxH)

m3/h
dB(A)
dB(A)
kg
mm

42QZL018DSA
950/850/750
58
46/43/39
26.5
1068x675x235

42QZL024DSA
1200/1050/850
63
52/50/45
26.5
1068x675x235

42QZL036DSA
2100/1800/1400
64
54/51/45
40
1650x675x235

42QZL048DSA
2100/1800/1400
65
54/50/45
40
1650x675x235

42QZL060DSA
2250/1900/1550
67
55/50/45
42
1650x675x235

OUTDOOR UNIT
Airflow
Sound pressure level

m3/h
dB(A)

38QUS018DSA
2000
58

38QUS024DSE
2500
61

38QUS036DSE
4300
63

38QUS048DTE
6800
63

38QUS060DTE
6800
63

Sound power level

dB(A)

63

68

69

74

74

Heating mode
Capacity
Capacity range (min-max)
Power consumption
COP
SCOP (average)
SCOP (warmer)
Energy class (average)
Energy class (warmer)
Seasonal energy consumption (average)
Seasonal energy consumption (warmer)

Operating range (cooling/heating)

BTU
kW
kW
kW
W/W
W/W
kWh

kW
kW
kW
W/W
W/W
W/W

-10~46 / -15~24

Dimensions (WxDxH)

mm

810x310x558

845x320x700

945x395x810

938x392x1369

938x392x1369

Weight (Net)

kg

37

47

72

103

103

inch

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

Standard piping length

Min piping length

Max piping length

25

25

30

30

30

Max height difference

10

10

10

15

15

Additional charge

15

30

30

30

30

V-Ph-Hz

220/240-1 -50

220/240-1 -50

220/240-1 -50

380/415-3 -50

380/415-3 -50

Flare connections (Liquid side Gas side)

Power supply

Note:
Cooling Capacities are based on 27C (DB) / 19C (WB) indoor air temperature and 35C (DB) / 24C (WB) outdoor air temperature.
Heating Capacities are based on 20C (DB) / 15C (WB) indoor air temperature and 7C (DB) / 6C (WB) outdoor air temperature.
The sound pressure level is given at 1m distance from outdoor units and 1,5m distance from indoor units.
H/M/L = High/Medium/Low speed
WxDxH = Width x Depth x Height

*Preliminary data

Inverter Cassette XPower | 42QTD/38QUS

FEATURES
The ideal solution for any commercial application.
Compact design.
Allows 360o airflow for optimum air distribution in the room.
Standard dimensions compatible with all suspended ceiling systems.
Fresh air intake and additional outlet grille that allows the air conditioning
of an adjoining room.
Fresh air inlet for constant air renewal.
Easy accessibility to the key components on the unit simply
by opening the grille or removing the front panel.

UNIT

REMOTE CONTROL

Built in Drain Pump that can lift the condensate water up to 750mm.
Choice of wired (optional) or wireless controls (standard).

LIGHT COMMERCIAL COMFORT SOLUTIONS

42

TECHNICAL SPECIFICATIONS*
Model IDU
Model CDU
Nominal

42QTD012DSA
38QUS012DSA
12.000

42QTD018DSA
38QUS018DSA
18.000

42QTD024DSA
38QUS024DSE
24.000

42QTD036DSA
38QUS036DSE
36.000

42QTD048DSA
38QUS048DTE
48.000

42QTD060DSA
38QUS060DTE
60.000

3,5
1,0~3,7
1,15
3,1
5,8
A+
211

5,2
2,1~5,5
1,84
2,9
5,9
A+
308

6,8
2,5~7,0
2,45
2,8
6,0
A+
397

10,3
5,3~12,0
4,35
2,4
6,0
A+
601

12,2
7,7~14,2
4,20
3,0
/
/
2100

13,0
7,5~15,8
4,70
2,8
/
/
2350

kW
kW
kW
W/W
W/W
W/W

3,6
1,0~4,1
1,30
2,8
3,8
5,1
A
A+++

5,4
2,0~6,0
1,65
3,3
3,8
5,1
A
A+++

6,8
2,4~7,0
2,20
3,1
3,8
4,6
A
A++

11,5
5,7~14,0
3,20
3,5
3,8
4,9
A
A++

14,5
7,5~18,0
4,80
3,2
/
/
/

17,0
7,4~20,2
5,70
2,9
/
/
/

kWh

995

1511

1879

3795

2400

2850

kWh

851

1235

2161

3000

m3/h
dB(A)
dB(A)
kg
kg
mm
mm

42QTD012DSA
650/530/450
57
46/42/38
16,0
2,5
570x570x260
647x647x50

42QTD018DSA
650/530/450
58
46/42/38
16,5
2,5
570x570x260
647x647x50

42QTD024DSA
1450/1250/1100
58
49/46/44
24,0
5,0
840x840x245
950x950x55

42QTD036DSA
1700/1460/1300
64
53/48/44
25,5
5,0
840x840x245
950x950x55

42QTD048DSA
1850/1600/1400
64
52/49/46
29,0
5,0
840x840x287
950x950x55

42QTD060DSA
1850/1600/1400
67
53/50/47
31,0
5,0
840x840x287
950x950x55

m3/h
dB(A)
dB(A)

38QUS012DSA
2000
54
62

38QUS018DSA
2000
58
63

38QUS024DSE
2500
61
68

38QUS036DSE
4300
63
69

38QUS048DTE
6800
63
74

38QUS060DTE
6800
63
74

BTU

Cooling mode
Capacity
Capacity range (min-max)
Power consumption
EER
SEER
Energy class
Seasonal energy consumption
Heating mode
Capacity
Capacity range (min-max)
Power consumption
COP
SCOP (average)
SCOP (warmer)
Energy class (average)
Energy class (warmer)
Seasonal energy consumption
(average)
Seasonal energy consumption
(warmer)
INDOOR UNIT
Air flow (H/M/L)
Sound power level
Sound pressure level (H/M/L)
Weight (Net)
Panel weight (Net)
Dimensions (WxDxH)
Panel dimensions (WxDxH)
OUTDOOR UNIT
Airflow
Sound pressure level
Sound power level
Operating range (cooling/
heating)
Dimensions (WxDxH)
Weight (Net)
Flare connections (Liquid side Gas side)
Standard piping length
Min piping length
Max piping length
Max height difference
Additional charge
Power supply

kW
kW
kW
W/W
W/W
kWh

-10~46 / -15~24

mm
kg

810x310x558
30,5

810x310x558
37,0

845x320x700
47,0

945x395x810
72,0

938x392x1369
103,0

938x392x1369
103,0

inch

1/4 - 3/8

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

m
m
m
m
m

5
3
20
8
15
220/240-1 -50

5
3
25
10
15
220/240-1 -50

5
3
25
10
30
220/240-1 -50

5
3
30
10
30
220/240-1 -50

5
3
30
15
30
380/415-3 -50

5
3
30
15
30
380/415-3 -50

V-Ph-Hz

Note:
Cooling Capacities are based on 27C (DB) / 19C (WB) indoor air temperature and 35C (DB) / 24C (WB) outdoor air temperature.
Heating Capacities are based on 20C (DB) / 15C (WB) indoor air temperature and 7C (DB) / 6C (WB) outdoor air temperature.
The sound pressure level is given at 1m distance from outdoor units and 1,5m distance from indoor units.
H/M/L = High/Medium/Low speed
WxDxH = Width x Depth x Height

*Preliminary data

Inverter Ducted XPower 42QSM/38QUS | 42QSM/38QUS

FEATURES
Compact and versatile is the ideal choice for new or refurbished
buildings.
Slim line profile that allows installation in applications with low
available height.
Reliable and durable unit thanks to high efficient DC rotary inverter
driven compressor.
Easy installation and maintenance as all components can be
accessed by removing the grille.
Equipped with fresh air intake.

UNIT

Choice of wired (optional) or wireless controls (standard).

REMOTE CONTROL

LIGHT COMMERCIAL COMFORT SOLUTIONS

44

TECHNICAL SPECIFICATIONS*
Model IDU
Model CDU
Nominal
Cooling mode
Capacity
Capacity range (min-max)
Power consumption
EER
SEER
Energy class
Seasonal energy consumption
Heating mode
Capacity
Capacity range (min-max)
Power consumption
COP
SCOP (average)
SCOP (warmer)
Energy class (average)
Energy class (warmer)
Seasonal energy consumption
(average)
Seasonal energy consumption
(warmer)
INDOOR UNIT
Air flow (H/M/L)
Sound power level
Sound pressure level (H/M/L)
Weight (Net)
Dimensions (WxDxH)
OUTDOOR UNIT
Airflow
Sound pressure level
Sound power level
Operating range (cooling/heating)
Dimensions (WxDxH)
Weight (Net)
Flare connections (Liquid side Gas side)
Standard piping length
Min piping length
Max piping length
Max height difference
Additional charge
Power supply

42QSM012DSA
38QUS012DSA
12.000

42QSM018DSA
38QUS018DSA
18.000

42QSM024DSA
38QUS024DSE
24.000

42QSM036DSA
38QUS036DSE
36.000

42QSM048DSA
38QUS048DTE
48.000

42QSM060DSA
38QUS060DTE
60.000

3,5
1,0~3,7
1,15
3,1
5,8
A+
211

5,2
2,1~5,5
1,84
2,9
5,9
A+
308

6,8
2,5~7,0
2,45
2,8
6
A+
397

10,3
5,3~12,0
4,35
2,4
6
A+
601

12,2
7,7~14,2
4,20
3,0
/
/
2100

13,0
7,5~15,8
4,70
2,8
/
/
2350

kW
kW
kW
W/W
W/W
W/W

3,6
1,0~4,1
1,30
2,8
3,8
5,1
A
A+++

5,4
2,0~6,0
1,65
3,3
3,8
5,1
A
A+++

6,8
2,4~7,0
2,20
3,1
3,8
4,6
A
A++

11,5
5,7~14,0
3,20
3,5
3,8
4,9
A
A++

14,5
7,5~18,0
4,80
3,2
/
/
/
/

17,0
7,4~20,2
5,70
2,9
/
/
/
/

kWh

995

1511

1879

3795

2400

2850

kWh

851

1235

2161

3000

m3/h
dB(A)
dB(A)
kg
mm

42QSM012DSA
520/450/380
56
42/40/38
18,5
700x635x210

42QSM018DSA
920/840/760
57
42/40/38
23
920x635x210

42QSM024DSA
1360/1200/1000
62
44/41/34
26,5
920x635x210

42QSM036DSA
1750/1500/1280
62
46/44/42
44
1200x865x300

42QSM048DSA
2200/1900/1600
65
50/47/44
45
1200x865x300

42QSM060DSA
2200/1900/1600
65
50/47/44
45
1200x865x300

38QUS012DSA
2000
54
62

38QUS018DSA
2000
58
63

38QUS048DTE
6800
63
74

38QUS060DTE
6800
63
74

810x310x558
30,5

810x310x558
37,0

938x392x1369
103,0

938x392x1369
103,0

inch

1/4 - 3/8

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

m
m
m
m
m

5
3
20
8
15
220/240 -1 -50

5
3
25
10
15
220/240 -1 -50

5
3
25
10
30
220/240 -1 -50

5
3
30
10
30
220/240 -1 -50

5
3
30
15
30
380/415 -3 -50

5
3
30
15
30
380/415 -3 -50

BTU
kW
kW
kW
W/W
W/W
kWh

m3/h
dB(A)
dB(A)

mm
kg

V-Ph-Hz

38QUS024DSE
38QUS036DSE
2500
4300
61
63
68
69
-10~46 / -15~24
845x320x700
945x395x810
47,0
72,0

Note:
Cooling Capacities are based on 27C (DB) / 19C (WB) indoor air temperature and 35C (DB) / 24C (WB) outdoor air temperature.
Heating Capacities are based on 20C (DB) / 15C (WB) indoor air temperature and 7C (DB) / 6C (WB) outdoor air temperature.
H/M/L = High/Medium/Low speed
WxDxH = Width x Depth x Height

*Preliminary data

Inverter Free Standing XPower | 42CFV/38VN

FEATURES
Elegant appearance and ultimate comfort with energy efficiency.
Efficient air management system.
Smart LCD display that shows control functions and error codes in
case of a malfunction.
Long lasting washable filter for clean air.
Smart self diagnostic function and refrigerant leak detection.
Turbo function in order to reach the desired temperature quickly.
Auto restart with the previous operations settings in case of power
failure.
Auto mode that allows changing automatically the operation mode
and the capacity according to temperature difference between
room and set point.
Independent dehumidification mode.
Programmable timer for energy savings.
Easy installation, maintenance and service.

UNIT

LIGHT COMMERCIAL COMFORT SOLUTIONS

46

TECHNICAL SPECIFICATIONS*
Model IDU
Model CDU
Nominal
Nominal cooling capacity (Min-Max)
EER
Nominal heating capacity (Min-Max)
COP
Indoor unit
Rated input
Dimensions (WxDxH)
Net weight
Outdoor unit
Rated input
Dimensions (WxDxH)
Net weight
Refrigerant type
Flare connections (Liquid side - Gas side )
Max. pipe length
Max. pipe height difference
Operating range (Cooling / Heating)
Power supply

42CFV2481001931
38VN2481193A
48000
13,8 (7,0~16,0)
2,75
16,5 (8,0~18,0)
3,15

42CFV2601001931
38VN2601193A
60000
16,0 (8,0~18,0)
2,45
18,0 (9,0~20,0)
3,05

W
mm
kg

335+3800
610x390x1925
69,3

350+3800
610x390x1925
69,6

W
mm
kg

7200
938x392x1369
102
R410A
3/8 - 5/8
65
30
-15~50 / -15~24
380/415-3-50

7500
938x392x1369
107
R410A
3/8 - 5/8
65
30
-15~50 / -15~24
380/415-3-50

BTU
kW
kW

inch
m
m

V-Ph-Hz

Note:
Cooling Capacities are based on 27C (DB) / 19C (WB) indoor air temperature and 35C (DB) / 24C (WB) outdoor air temperature.
Heating Capacities are based on 20C (DB) / 15C (WB) indoor air temperature and 7C (DB) / 6C (WB) outdoor air temperature.
WxDxH = Width x Depth x Height

*Preliminary data

Encased Indoor Fan Coils | FX4CS/38EYX

Suitable for all light commercial applications.


Exceptional installation flexibility: the indoor unit can be installed in three air
flow positions (upwards, downwards or horizontal).
Refrigerant circuit service valves with easily accessible pressure test ports for
startup and maintenance.
Heat pump cycle with four position valve and electronic control system for
optimized defrosting.
High and low pressure safety switched fitted as standard.
Outdoor unit compressors are hermetically sealed against contamination and
pollutants to ensure long life and reliability.

INDOOR UNIT
OUTDOOR UNIT

LIGHT COMMERCIAL COMFORT SOLUTIONS

48

TECHNICAL SPECIFICATIONS*
Model IDU
Model CDU
Nominal
Cooling mode
Capacity
Power consumption
EER

BTU

FX4CSX048000
38EYX048-X-9
48.000

FX4CSX060000
38EYX060-X-9
60.000

kW
kW
W/W

13,66
4,36
3,13

16,73
5,87
2,85

Heating mode
Capacity
Power consumption
COP

kW
kW
W/W

14,48
3,82
3,79

17,07
5,04
3,39

INDOOR UNIT
Nominal air flow (H)
Dehumidification
Nominal static pressure
Sound pressure level
Sound power level
Dimensions (WxDxH)
Weight (Net)

l/s
l/h
Pa
dB(A)
dB(A)
mm
kg

FX4CSX048000
750
7,00
125
77
61
537x560x1261
72

FX4CSX060000
825
8,20
125
80
64
537x560x1357
80

38EYX048-X-9
Scroll
5098
72
52
12

38EYX060-X-9
Scroll
4248
74
54
14

OUTDOOR UNIT
Compressor type
Airflow (cooling)
Sound pressure level (cooling)
Sound power level (cooling)
Maximum running current (cooling)
Operating range (cooling /heating)
Dimensions (WxDxH)
Weight (Net)
Chargeless pipe length
Max. piping length
Max. height difference
Flare connections (Liquid side - Gas side)
Power supply

m3/h
dB(A)
dB(A)
A

mm
kg
m
m
m
inch
V-Ph-Hz

13~52 / -34~19
762x762x1015
99,30

762x762x862
111,60
4,5
50
45
3/8"- 7/8"
400-3-50

Note:
Cooling Capacities are based on 27C (DB) / 19C (WB) indoor air temperature and 35C (DB) / 24C (WB) outdoor air temperature.
Heating Capacities are based on 20C (DB) / 15C (WB) indoor air temperature and 7C (DB) / 6C (WB) outdoor air temperature.

*Preliminary data

You might also like