You are on page 1of 14

MOTOR

EQUIPO
BC-201A
BC-201R
BC-1
BC-2

CARGA ESTATICA
CARGA DINAMICA

PTA.

DIA. POLEA
EN PULG.

RPM

HP.

2
2
1
1

14.0
14.0
13.0
14.0

1790
1790
1785
1785

300
300
350
300

21 m
7.4 m

L. EQUIVALENTE (m)
VISCOSIDAD (Pas)
DENSIDAD (kg/m3)
D10" (m)
D12" (m)
GASTO (m3/h)
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
770
800
850
900
950
1000
1050

104.267
0.001
1000
e/D
w
0.254
0.00491803 0.79472169
0.305
VELOCIDAD (m/s)
Nre D=12"
f D=12"
0.00
0.00 0.0000E+00
0.0000
0.19
0.27 5.7980E+04
0.0323
0.38
0.55 1.1596E+05
0.0316
0.57
0.82 1.7394E+05
0.0314
0.76
1.10 2.3192E+05
0.0313
0.95
1.37 2.8990E+05
0.0312
1.14
1.64 3.4788E+05
0.0311
1.33
1.92 4.0586E+05
0.0311
1.52
2.19 4.6384E+05
0.0311
1.71
2.47 5.2182E+05
0.0311
1.90
2.74 5.7980E+05
0.0310
2.09
3.02 6.3778E+05
0.0310
2.28
3.29 6.9576E+05
0.0310
2.47
3.56 7.5374E+05
0.0310
2.66
3.84 8.1172E+05
0.0310
2.85
4.11 8.6970E+05
0.0310
2.93
4.22 8.9289E+05
0.0310
3.04
4.39 9.2768E+05
0.0310
3.23
4.66 9.8566E+05
0.0310
3.42
4.93 1.0436E+06
0.0310
3.61
5.21 1.1016E+06
0.0310
3.80
5.48 1.1596E+06
0.0310
3.99
5.76 1.2176E+06
0.0310

1100
1150
1200
1250
1300
1350
1400
1450
1500
1550
1600
1650
1700
1750
1800
1850
1900
1950
2000
2050
2100
2150
2200
2250
2300
2350
2400
2450
2500
2550
2600
2650
2700
2750
2800
2850
2900
2950
3000

4.18
4.37
4.56
4.75
4.94
5.13
5.32
5.51
5.70
5.89
6.08
6.27
6.46
6.65
6.84
7.03
7.22
7.41
7.60
7.79
7.98
8.17
8.36
8.55
8.74
8.93
9.12
9.31
9.50
9.70
9.89
10.08
10.27
10.46
10.65
10.84
11.03
11.22
11.41

6.03
6.30
6.58
6.85
7.13
7.40
7.67
7.95
8.22
8.50
8.77
9.05
9.32
9.59
9.87
10.14
10.42
10.69
10.96
11.24
11.51
11.79
12.06
12.33
12.61
12.88
13.16
13.43
13.71
13.98
14.25
14.53
14.80
15.08
15.35
15.62
15.90
16.17
16.45

1.2756E+06
1.3335E+06
1.3915E+06
1.4495E+06
1.5075E+06
1.5655E+06
1.6234E+06
1.6814E+06
1.7394E+06
1.7974E+06
1.8554E+06
1.9133E+06
1.9713E+06
2.0293E+06
2.0873E+06
2.1453E+06
2.2032E+06
2.2612E+06
2.3192E+06
2.3772E+06
2.4352E+06
2.4931E+06
2.5511E+06
2.6091E+06
2.6671E+06
2.7251E+06
2.7830E+06
2.8410E+06
2.8990E+06
2.9570E+06
3.0150E+06
3.0729E+06
3.1309E+06
3.1889E+06
3.2469E+06
3.3049E+06
3.3628E+06
3.4208E+06
3.4788E+06

0.0310
0.0310
0.0310
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309
0.0309

* un codo mitrado de 5 secciones genera aprox. 3 veces mas cada de presin que un codo estandar

CONCLUSIONES

RELACION DE BOMBAS DE ALIMENTACIN A HIDROSIZERS


MOTOR
BOMBA
AMPERAJE
AMP.
DIA. POLEA EN
VOLTAJE.
NOMINAL
L-1
L-2
L-3
PULG.
4160
37
35
35
34
35
4160
37
38
40
32
35
386
460
201
188
191
35.5
336
460
35.5
Accesorio
Tubera 10" (m)
Tubera 12" (m)
curva 90
Codo 90 rC
Codo 45
V. compuerta (cuchilla)
*Codo mitrado 90

Codo 90 rL
hf D=12"
Nre D=10"
0.000 0.0000E+00
0.020 6.9622E+04
0.080 1.3924E+05
0.178 2.0886E+05
0.315 2.7849E+05
0.491 3.4811E+05
0.706 4.1773E+05
0.959 4.8735E+05
1.252 5.5697E+05
1.584 6.2659E+05
1.954 6.9622E+05
2.364 7.6584E+05
2.812 8.3546E+05
3.299 9.0508E+05
3.825 9.7470E+05
4.390 1.0443E+06
4.627 1.0722E+06
4.994 1.1139E+06
5.637 1.1836E+06
6.318 1.2532E+06
7.039 1.3228E+06
7.798 1.3924E+06
8.597 1.4621E+06

Cantidad
4.68
37.167
1
0
4
3
2

L/D

D=10"

0.0000
0.0335
0.0330
0.0328
0.0328
0.0327
0.0327
0.0326
0.0326
0.0326
0.0326
0.0326
0.0326
0.0326
0.0326
0.0326
0.0326
0.0326
0.0325
0.0325
0.0325
0.0325
0.0325

hf D=10"
0.000
0.002
0.009
0.021
0.037
0.058
0.083
0.113
0.147
0.186
0.230
0.278
0.331
0.388
0.450
0.517
0.545
0.588
0.664
0.744
0.829
0.918
1.012

LG equivalente
11
37.167
20
6.1
30
0
16
19.52
8
7.32
40
24.4

16

9.76

21.0
21.0
21.1
21.2
21.4
21.6
21.9
22.2
22.5
22.9
23.4
23.9
24.4
25.0
25.6
26.3
26.6
27.1
27.8
28.7
29.5
30.5
31.4

hT CORREGIDO
27.741
27.774
27.868
28.025
28.245
28.527
28.871
29.277
29.746
30.276
30.870
31.525
32.243
33.023
33.866
34.771
35.150
35.738
36.767
37.859
39.013
40.229
41.508

hT

9.434
10.310
11.225
12.179
13.172
14.204
15.274
16.384
17.532
18.720
19.946
21.211
22.515
23.858
25.240
26.660
28.120
29.619
31.156
32.732
34.348
36.002
37.695
39.427
41.197
43.007
44.856
46.743
48.670
50.635
52.639
54.682
56.764
58.885
61.045
63.244
65.481
67.758
70.073

1.5317E+06
1.6013E+06
1.6709E+06
1.7405E+06
1.8102E+06
1.8798E+06
1.9494E+06
2.0190E+06
2.0886E+06
2.1583E+06
2.2279E+06
2.2975E+06
2.3671E+06
2.4368E+06
2.5064E+06
2.5760E+06
2.6456E+06
2.7152E+06
2.7849E+06
2.8545E+06
2.9241E+06
2.9937E+06
3.0634E+06
3.1330E+06
3.2026E+06
3.2722E+06
3.3418E+06
3.4115E+06
3.4811E+06
3.5507E+06
3.6203E+06
3.6899E+06
3.7596E+06
3.8292E+06
3.8988E+06
3.9684E+06
4.0381E+06
4.1077E+06
4.1773E+06

esin que un codo estandar

0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325
0.0325

1.111
1.214
1.322
1.434
1.551
1.673
1.799
1.930
2.065
2.205
2.350
2.499
2.652
2.810
2.973
3.141
3.313
3.489
3.670
3.856
4.046
4.241
4.441
4.645
4.853
5.067
5.285
5.507
5.734
5.965
6.202
6.442
6.688
6.938
7.192
7.451
7.715
7.983
8.256

32.4
33.5
34.6
35.8
37.0
38.2
39.5
40.9
42.3
43.7
45.2
46.7
48.3
49.9
51.6
53.3
55.1
56.9
58.8
60.7
62.6
64.6
66.7
68.8
70.9
73.1
75.4
77.7
80.0
82.4
84.8
87.3
89.8
92.4
95.0
97.7
100.4
103.2
106.0

42.849
44.252
45.717
47.245
48.835
50.488
52.203
53.980
55.819
57.721
59.685
61.711
63.800
65.951
68.164
70.439
72.777
75.177
77.640
80.165
82.752
85.401
88.113
90.887
93.723
96.621
99.582
102.606
105.691
108.839
112.049
115.321
118.656
122.053
125.513
129.034
132.618
136.265
139.973

RS
BOMBA
TAMAO
12x10x24
12x10x24
12x10x24
12x10x24

RPM CALC.

CARGA
TOTAL

716
716
654
704

35.150
35.150
35.150
35.150

0.757 +/- 0.005

OBSERVACIONES
HM-300
HM-300
Thomas JLSA33 frame 5
HM 300 FHC-S

3.4 m/s (11.1 ft/s)

770

80.000

f(x) = 1.24613293986993E-005x^2 + 2.67090583167814E-005x + 27.7410196867


R = 1
f(x) = - 3.52856896428571E-006x^2 + 0.0045052375x + 73.821417925
R = 0.999340937

70.000

60.000
f(x) = - 3.79048571428572E-006x^2 + 0.0044476714x + 58.2313571429
R = 0.9989168868

Curva del Sistema


Power (Curva del Sistema)
Polynomial (Curva del Sistema)

50.000

400 RPM
Polynomial (400 RPM)

H (m)

650
40.000
RPM

f(x) = - 3.55237904571428E-006x^2 + 0.0035247594x + 44.5771404771


R = 0.9984520791

500 RPM
Polynomial (500 RPM)
600 RPM
Polynomial (600 RPM)

615 RPM

f(x) = - 3.5334E-006x^2 + 0.00302014x + 32.74327


R = 0.9879253353

30.000

700 RPM
Polynomial (700 RPM)
800 RPM
Polynomial (800 RPM)

f(x) = - 0.0000032x^2 + 0.00216x + 22.64666


R = 0.9992907801

20.000

900 RPM
Logarithmic (900 RPM)

f(x) = - 3.1333333332667E-006x^2 + 0.0017266667x + 14.3966666667


R = 0.9940950356

10.000

0.000
0

500

770

1000

947

1500
Q (m3/h)

2000

2500

3000

3500

Polynomial (900 RPM)

70.000

60.000

50.000
Curva del Sistema
Power (Curva del Sistema)
Polynomial (Curva del Sistema)

40.000

600 RPM
Polynomial (600 RPM)

H (m)

700 RPM
Polynomial (700 RPM)

30.000

800 RPM
Polynomial (800 RPM)
900 RPM
20.000

Logarithmic (900 RPM)


Polynomial (900 RPM)

10.000

0.000
0

200

400

600
Q (m3/h)

800

1000

Anlisis y comparacin de la velocidad


de rotacin de las bombas BC-201A-R y BC-1-2
La carga esttica se estim 5 cm arriba de la parte superior de la succin de la
bomba hasta la entrada al tanque distribuidor del Hydrosizer (SD-201A-B) ms 20
cm; la diferencia de carga entre los calculos de Jacobs Engineering y el presente, se
debe a que Jacobs consider tubera de 10" de dimetro.
Se encontr que la velocidad crtica de sedimentacin es de 3.4 m/s 15%, la
velocidad que alcanza el flujo de 770 m3/h en la tubera de 12" es de 2.93 m/s valor
14% menor a la velocidad crtica, que, aunque se encuentra dentro del margen de
error, supone una mayor probabilidad de arenamiento de la lnea.
La carga dinmica se determin suponiendo un flujo de agua pura, para hacer la
correccin de la curva de operacin del sistema se utiliz la informacin de la fig 1
de la pestaa "clculo BC-201A-B"; considerando una gravedad especfica de slido
de 2.5 y una concentracin de 44% en peso, se determin un factor de correccin de
carga igual a 0.757, con lo que se estim que la velocidad de rotacin para las
bombas HM 300 C5 debera ser 615 RPM con un impulsor de 750 mm (29.5") de
dimetro, para las *24" del impulsor actual se ocupan 650 RPM, velocidad menor a
las 716 RPM que se obtienen con la relacin de poleas actual.
Para la bomba Thomas XM 250 la velocidad de rotacin debera ser 700 RPM con un
impulsor de 660 mm (26") de dimetro, para las *24" del impulsor actual se
necesitan 775 RPM, velocidad menor a las 654 RPM que se obtienen con la relacin
de poleas actual.
NOTA: Las RPM con las que se comparan las obtenidas mediante el estudio son las
que permiten las relaciones de poleas actuales, las RPM reales pudieran ser menores
a estas dependiendo del estado de las poleas.
*No se verific fisicamente el dimetro del impulsor.

*No se verific fisicamente el dimetro del impulsor.

C-1-2

a succin de la
-201A-B) ms 20
ng y el presente, se

m/s 15%, la
s de 2.93 m/s valor
tro del margen de
.

a, para hacer la
macin de la fig 1
especfica de slido
tor de correccin de
acin para las
0 mm (29.5") de
velocidad menor a

ser 700 RPM con un


or actual se
nen con la relacin

el estudio son las


udieran ser menores

You might also like