You are on page 1of 4

PHconfrol

1.Auto control the ph to objective value by the


signal.from PH meter.
2.Dp pump can receive the pluse signal from PH
meter.
3.DM pump can receive the 4-20mA signal form PH
meter.
4.not added meter

pluse sigual control

Pluse signal control


Signal type:Spuave wave or node signal can input the pump.

analog signal contuol

1.Pump receive the analog signal without added control meter.


2.014-20mA analog signal start or over point can be set.
3.The proportion of plsitive and negative control.

Beijing Fangzhou TongDa Machinery & Electron Technology Co.,Ltd.

NEWDOSE


ARK Electric & Mechanical Ltd.Co.
CASE STUDIES

1 Transform nonlinear sighal to auto contrallable


signal without contrd meter
2 Above case can be used in temperature.
conductivty and soon
PUMP

Company profile:
FangZhou
Tong Da

ARK Electric & Mechanical Ltd.Co. is a enterprise which


reserch. manfacture.sale.service of High-tech products.

ALARM

1.Control the pump about signal keep original


status when start,The fuction of DFD pamp.
2.Receive signal Alarm and stop pamp on lav
liquid level

Products

3.Display screen to display flow rate.

NEWDOSE electrical diaphragm metering pump


NEWDOSE paddle flow meter
Ark series industrial controller meter

Corporate culture
Bossmanship:Innovation Repatation-based
Company tent:Quality first.llsers first.

1.Adjust pump Aby signal from flwo meter.


The signal from A pump to B and C
2.Receive the symchronous signal from pamp
A.pamp B and pump C about proportion

NEWDOSE

NEWDOSE


ARK Electric & Mechanical Ltd.Co.

Specification of the DFD pump


Type
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R
DFD/DFD-R

Capacity L/h
-02-07-L
-02-16-X
-03-07-L
-06-05-L
-06-07-X
-09-03-L
-09-07-X
-12-07-X
-15-03-X
-20-03-X
-30-03-X
-50-02-X

2
2
3
6
6
9
9
12
15
20
30
50

ARK Electric & Mechanical Ltd.Co.

Specification of the DC pump


Max Pres. Bar
7
16
7
5
7
3
7
7
3
3
3
2

Strokes number/1 Max suction m Weight Kg Power W


120
120
120
140
120
140
120
120
120
160
160
160

2
2
2
2
2
2
2
2
2
2
2
2

3.2
3.8
3.2
3.2
3.8
3.2
3.8
3.8
3.8
3.8
4.5
4.5

30
65
30
30
65
30
65
65
65
65
65
65

Electrical Source
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V

50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ

Type

Size
A
B
A
A
B
A
B
B
B
B
C
C

DC/DC-R
DC/DC-R
DC/DC-R
DC/DC-R
DC/DC-R
DC/DC-R
DC/DC-R
DC/DC-R
DC/DC-R
DC/DC-R
DC/DC-R
DC/DC-R

Capacity L/h

-02-07-L
-02-16-X
-03-07-L
-06-05-L
-06-07-X
-09-03-L
-09-07-X
-12-07-X
-15-03-X
-20-03-X
-30-03-X
-50-02-X

Max Pres. BarStrokes number/1 Max suction m

2
2
3
6
6
9
9
12
15
20
30
50

7
16
7
5
7
3
7
7
3
7
3
2

120
120
120
140
120
140
120
120
120
160
160
160

Weight Kg

Power W

3.2
3.8
3.2
3.2
3.8
3.2
3.8
3.8
3.8
3.8
4.5
4.5

30
65
30
30
65
30
65
65
65
65
65
65

2
2
2
2
2
2
2
2
2
2
2
2

Electrical Source
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V

50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ

Size
A
B
A
A
B
A
B
B
B
B
C
C

DMDPDFDDC dosing pump installation direction


Specification of the DP pump
Type

DP/DP-R
DP/DP-R
DP/DP-R
DP/DP-R
DP/DP-R
DP/DP-R
DP/DP-R
DP/DP-R
DP/DP-R
DP/DP-R
DP/DP-R
DP/DP-R

-02-07-L
-02-16-X
-03-07-L
-06-05-L
-06-07-X
-09-03-L
-09-07-X
-12-07-X
-15-03-X
-20-03-X
-30-03-X
-50-02-X

Capacity L/h

2
2
3
6
6
9
9
12
15
20
30
50

Max Pres. Bar Strokes number/1 Max suction m

7
16
7
5
7
3
7
7
3
3
3
2

120
120
120
140
120
140
120
120
120
160
160
160

2
2
2
2
2
2
2
2
2
2
2
2

Weight Kg

Power W

3.2
3.8
3.2
3.2
3.8
3.2
3.8
3.8
3.8
3.8
4.5
4.5

30
65
30
30
65
30
65
65
65
65
65
65

Weight Kg

Power W

3.2
3.8
3.2
3.2
3.8
3.2
3.8
3.8
3.8
3.8
4.5
4.5

30
65
30
30
65
30
65
65
65
65
65
65

Electrical Source

220V
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V

50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ

Size
A
B
A
A
B
A
B
B
B
B
C
C

Flow-Pressure Diagram

Specification of the DM pump


Type
DM/DM-R
DM/DM-R
DM/DM-R
DM/DM-R
DM/DM-R
DM/DM-R
DM/DM-R
DM/DM-R
DM/DM-R
DM/DM-R
DM/DM-R
DM/DM-R

Capacity L/h
-02-07-L
-02-16-X
-03-07-L
-06-05-L
-06-07-X
-09-03-L
-09-07-X
-12-07-X
-15-03-X
-20-03-X
-30-03-X
-50-02-X

2
2
3
6
6
9
9
12
15
20
30
50

Max Pres. Bar


7
16
7
5
7
3
7
7
3
7
3
2

Strokes number/1 Max suction m

120
120
120
140
120
140
120
120
120
160
160
160

2
2
2
2
2
2
2
2
2
2
2
2

Electrical Source
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V
220V

50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ
50HZ

Size
A
B
A
A
B
A
B
B
B
B
C
C

C
Code

Material Table
DFD

Code

Pump head

The ball

The valve

Diaphragm

metiral number
flow rate
manwual stroke adjust
fuction number

11

SS316

SS316

SS316

PTFE

12

PP

CERAMIC

PTFE

PTFE

13

PVC

CERAMIC

PTFE

PTFE

NEWDOSE

NEWDOSE


ARK Electric & Mechanical Ltd.Co.

ARK Electric & Mechanical Ltd.Co.

Standard Assemble Parts

1.5m saction tube

1.5m exclude tube

injection valve

filter valve

Spare Parts

siphon valve

siphon(controllable valve)

exhaust valve

uni-directional

connective valve

diaphragm

soft tube

DFD type electrical diaphragm metering pump

Anticorrosive plastic casing


PTFE diaphragm
Protection class IP55
PPPVCPTFESS316 Pump head PPPVCPTFESS316
Suction and delivery valves with two balls each one
220VAC 50Hz Electrical Source 220VAC 50Hz single phase
0-100% Manual control the stroke frequency from 0-100%
LED display the normal frequencyat running or stop

DC type electrical diaphragm metering pump

OEM
1 Can supply different shape and color for user
2 Can supply the individual control panel
3Can supply the pump with RS485 communication port and RF port

Anticorrosive plastic casing


PTFE diaphragm
Protection class IP55
PPPVCPTFESS316 Pump head PPPVCPTFESS316
Suction and delivery valves with two balls each one
220VAC 50Hz Electrical Source 220VAC 50Hz single phase
0-100% Manual control the stroke frequency from 0-100%
LCD display the normal frequencyat running or stop
RS485 RS485 communication

DC pump

DC pump

DC pump

Pump Control
Start
1DFD/DP/DM/DC
Stop

DFD/DP/DM/DC

DC pump

2DFD/DP/DM/DC Long-distance on/off control by two ways.


ARK-SMART

1 control on/off sigual input the controllable node of pump


2 control on/off signal connect pump circuit DP pump can be adjust capacity
by plase signal.
Pluse signal:input the pluse control node pamp.
Pluse signal tgpe:Active pluse

or solid state node outpat of relay.

Pluse frequency range:0-999/min


DM pamp can be adjust capacity by 0/4-20mA or0/1-5V direct current
voltsdt

solution tank

DM type electrical diaphragm metering pump

DP type electrical diaphragm metering pump

Anticorrosive plastic casing


PTFE diaphragm
Protection class IP55
PPPVCPTFESS316 Pump head PPPVCPTFESS316
Suction and delivery valves with two balls each one
220VAC 50Hz Electrical Source 220VAC 50Hz single phase
0-100% Manual control the stroke frequency from 0-100%
LED display the normal frequencyat running or stop
Auto control the stroke frequency by the analog signal 0/4-20mA
or 0/1-5VDC from 0-100%,LCD displays the normal frequency (at
running or stop) the proportion rate and direction can be changed
easily.

Anticorrosive plastic casing


PTFE diaphragm
Protection class IP55
PPPVCPTFESS316 Pump head PPPVCPTFESS316
Suction and delivery valves with two balls each one
220VAC 50Hz Electrical Source 220VAC 50Hz single phase
0-100%Manual control the stroke frequency from 0-100%LED
display the normal frequencyat running or stop
Auto control the stroke frequency by the impulse signal from
0-100%, Can be set 1*N or N/1,( 1*Nreceive one impulse, the
pump runs N strokes, N/1receive N impulse the pump runs once.
The scope of N1-999) LED displays the number N.

You might also like