VFL - C 2
Engineering Data
REMARK: Do not use for construction. Refer to factory certified dimensions & weights. This brochure includes data
current at time of publication, which should be reconfirmed at the time of purchase. In the interest of product
improvement, specifications, weights and dimensions are subject to change without notice. Up-to-date engineering
data and more can be found at www.BaltimoreAircoil.com.
VFL
VFL 24 X - VFL 48 X
1. Fluid in ND100; 2. Fluid Out ND100; 3.Access Door; 4. Make Up ND25; 5. Overflow ND50 for VFL 24X - VFL 36x and ND80 for VFL 48X; 6.
Drain ND50; 7. Vent ND15.
Model No.
VFL
Operating
Weight
(kg)
Shipping
Weight
(kg)
Heaviest
Section
(kg)
H
(mm)
L
(mm)
L2
(mm)
W
(mm)
Air
Flow
(m3/s)
Fan
Motor
(kW)
Spray
Water
Flow
(l/s)
Pump
Motor
(kW)
Coil
Volume
(L)
VFL 241-H
VFL 242-H
VFL 242-J
VFL 243-J
1950
2220
2230
2470
1280
1460
1490
1670
1280
1460
1490
1670
1855
2015
2015
2230
3350
3350
3350
3350
1820
1820
1820
1820
1250
1250
1250
1250
7,6
7,4
8,1
7,9
4
4
5,5
5,5
5,9
5,9
5,9
5,9
0,55
0,55
0,55
0,55
(1x) 176
(1x) 229
(1x) 229
(1x) 282
VFL 361-L
VFL 361-M
VFL 362-M
VFL 363-K
VFL 363-M
2800
2810
3130
3470
3540
1810
1820
2090
2280
2350
1810
1820
2090
2280
2350
1855
1855
2090
2350
2350
4560
4560
4560
4560
4560
2730
2730
2730
2730
2730
1250
1250
1250
1250
1250
12,7
13,8
13,4
10,8
13,0
11
15
15
7,5
15
9,0
9,0
9,0
9,0
9,0
0,75
0,75
0,75
0,75
0,75
(1x) 258
(1x) 258
(1x) 338
(1x) 418
(1x) 418
VFL 481-M
VFL 482-L
VFL 483-L
VFL 483-M
VFL 484-M
3490
3930
4390
4400
4860
2170
2490
2830
2840
3170
2170
2490
2830
2840
3170
1855
2090
2350
2350
2560
5480
5480
5480
5480
5480
3650
3650
3650
3650
3650
1250
1250
1250
1250
1250
15,1
13,6
13,4
14,6
14,3
15
11
11
15
15
12,1
12,1
12,1
12,1
12,1
1,1
1,1
1,1
1,1
1,1
(1x) 341
(1x) 448
(1x) 556
(1x) 556
(1x) 664
Baltimore Aircoil
VFL - C 3
VFL 72 X - VFL 96 X
Model No.
VFL
Operating
Weight
(kg)
Shipping
Weight
(kg)
Heaviest
Section
(kg)
H
(mm)
L1
(mm)
L2
(mm)
W
(mm)
Air
Flow
(m3/s)
Fan
Motor
(kW)
Spray
Water
Flow
(l/s)
Pump
Motor
(kW)
Coil
Volume
(L)
VFL 721-L
VFL 721-M
VFL 721-O
VFL 722-N
VFL 722-O
VFL 723-L
VFL 723-O
VFL 724-O
5150
5160
5190
5880
5900
6610
6650
7320
3150
3160
3190
3700
3720
4210
4250
4790
3150
3160
3190
3700
3720
4210
4250
4790
1855
1855
1855
2090
2090
2350
2350
2560
4560
4560
4560
4560
4560
4560
4560
4560
2730
2730
2730
2730
2730
2730
2730
2730
2400
2400
2400
2400
2400
2400
2400
2400
20,0
21,8
24,6
22,8
24,0
19,3
23,4
22,9
11
15
22
18,5
22
11
22
22
17,9
17,9
17,9
17,9
17,9
17,9
17,9
17,9
1,1
1,1
1,1
1,1
1,1
1,1
1,1
1,1
(2x) 258
(2x) 258
(2x) 258
(2x) 338
(2x) 338
(2x) 418
(2x) 418
(2x) 498
VFL 961-P
VFL 962-N
VFL 962-O
VFL 962-P
VFL 963-O
VFL 963-P
VFL 964-P
6520
7285
7310
7400
8210
8310
9300
3850
4360
4400
4500
5060
5160
5810
3850
4360
4400
4500
5080
5160
5810
1855
2090
2090
2090
2350
2350
2560
5480
5480
5480
5480
5480
5480
5480
3650
3650
3650
3650
3650
3650
3650
2400
2400
2400
2400
2400
2400
2400
28,7
24,5
25,9
28,3
25,6
27,9
27,4
30
18,5
22
30
22
30
30
24,2
24,2
24,2
24,2
24,2
24,2
24,2
2,2
2,2
2,2
2,2
2,2
2,2
2,2
(2x) 341
(2x) 448
(2x) 448
(2x) 448
(2x) 556
(2x) 556
(2x) 664
General Notes
1. All location dimensions for coil connections are approximate and
should not be used for prefabrication of connecting piping.
2. If discharge hoods with positive closure dampers are furnished,
see table in section Engineering Data Straight Discharge Hood
with PCD for added weight and height.
3. For external static pressure up to 125 Pa use next larger motor
size.
4. For indoor applications of fluid coolers, the room may be used as
a plenum with ductwork attached to the discharge only. If inlet
ductwork is required, an enclosed fan section must be specified;
consult your BAC Balticare representative for details.
1. Fluid in ND100; 2. Fluid Out ND100; 3.Access Door; 4. Make Up ND50; 5. Overflow ND80; 6. Drain ND50; 7. Vent ND15.
VFL - C 4
Sound Attenuation
VFL
1.Discharge attenuator, 2. Access Door, 3. Intake Attenuator; W & H = Unit Dimensions (See Engineering Data).
Model No
VFL
Dimensions (mm)
L2
L1
Intake
Attenuator
Discharge
Attenuator
Total
VFL 24X
3125
1820
655
235
890
VFL 36X
3375
2730
660
315
975
VFL 48X
3375
3650
660
385
1045
VFL 72X
3375
2730
980
500
1480
VFL 96X
3375
3650
980
605
1585
Baltimore Aircoil
VFL - C 5
Structural Support
REMARK: Do not use for construction. Refer to factory certified dimensions & weights. This brochure includes data
current at time of publication, which should be reconfirmed at the time of purchase. In the interest of product
improvement, specifications, weights and dimensions are subject to change without notice. Up-to-date engineering
data and more can be found at www.BaltimoreAircoil.com.
The recommended support arrangement for units consists of parallel I-beams running the full length of the unit, spaced as shown in the following
drawing. Besides providing adequate support, the steel also serves to raise the unit above any solid foundation to ensure access to the bottom
of the unit. To support units in an alternate steel support arrangement, consult your BAC Balticare Representative.
Model No.
VFL
A
(mm)
B
(mm)
Maximum Allowable
Beam Deflection
(mm)
VFL 24X
VFL 36X
VFL 48X
2426
3334
4253
1194
1194
1194
10
13
13
VFL 72X
VFL 96X
3334
4253
2344
2344
13
13
1. (4) 22 mm mounting holes; 2. Support Beams; 3. Fan Side; 4. Outline of Unit; 5. Outline of Attenuator HD (optional).
Notes:
1. The recommended support arrangement for these units consists
of two parallel I-beams extending the full length of the unit.
Supports and anchor bolts are to be designed and furnished by
others.
2. All supporting beams are to be flush and level at top and must be
oriented relative to gage line as shown.
3. Recommended design loads for each unit support beam should
be 70% of the total unit operating weight applied as a uniform
load to each of the unit beams. Beams should be designed in
VFL - C 6
Engineering Specifications
VFL
Baltimore Aircoil
VFL - C 7
5.0 Access
5.1 Basin Access: Circular access doors shall be provided for easy
access to the make-up water assembly and suction strainer for
routine maintenance.
6.0 Sound
Location
63
125
250
500
cooling tower operating at full fan speed shall not exceed the sound
levels detailed below.
1000
2000
4000
Discharge
Air Inlet
End
Back
8000
dB(A)