You are on page 1of 72

UCS Fabric Fundamentals

BRKCOM-1001

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Hardware State Abstraction

MAC Address
NIC Firmware
NIC Settings

LAN Connectivity
BRKCOM-1001

UUID
BIOS Firmware
BIOS Settings
State
Boot Order

BMC Firmware

Drive Controller F/W


Drive Firmware

abstracted from hardware

OS & Application
2013 Cisco and/or its affiliates. All rights reserved.

WWN Address
HBA Firmware
HBA Settings

Storage Connectivity
Cisco Public

Agenda
Introduction

UCS Key Features


Hardware Overview
Ethernet Connectivity
Storage Connectivity
Demo

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

More UCS sessions


Date
Session
Wednesday
BRKCOM-1005
Thursday
BRKCOM-1004
BRKCOM-2002
BRKCOM-2003
BRKCOM-2008
Friday
BRKCOM-2001
BRKCOM-3001

BRKCOM-1001

Title
UCS Architecture Overview
Automating UCS for Systems Administrators
UCS Supported Storage Architectures
UCS Networking - Deep Dive including VM-FEX
UCS Firmware Management Architecture
UCS Management Architecture - Deep Dive
Troubleshooting the Cisco UCS Compute Deployment

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Introduction

Building Blocks of Cisco UCS


UCS Manager
Embedded manages entire UCS
UCS Fabric Interconnect
10GE unified fabric switch

UCS Fabric Extender (I/O Module)


Remote line card

UCS Blade Server Chassis


Flexible bay configurations

UCS Blade and Rack Servers


x86 industry standard
Patented extended memory
UCS I/O Adapters
Choice of multiple adapters
BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Logical Architecture
SAN A
ETH 1

ETH 2

SAN B

MGMT

MGMT
Uplink Ports
OOB Mgmt
Fabric Switch
Server Ports

Fabric
Extenders

FI A
Cluster

IO
M
A

Virtualised Adapters
Compute Blades
Half / Full width
BRKCOM-1001

FI B

Chassis 1

CNA1

IO
M

IO
M

Half blade
2013 Cisco and/or its affiliates. All rights reserved.

Chassis 20

CNA1

CNA2

Full blade
Cisco Public

IO
M
B

Software Architecture
UCS Manager (UCSM or SAM)
External Interface Layer

Data Management Engine


(DME)

Application / EP Gateways
(AG)

Managed End Points (EP)

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Service Profiles
Server Name
Server Name
UUID
UUID
MAC
MAC
WWN
WWN
Boot
info
Boot
info
LAN
Config
LAN
Config
SAN
Config
SAN Config

UUID, MAC,WWN
Boot info
LAN, SAN Config
Run-time
association
Firmware

Logical container of server state


information
User-defined
Each profile can be individually created
Profiles can be generated from a template

Applied to physical blades at run time


Without profiles, blades are just anonymous
hardware components

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS Key Features

Cisco Unified Computing System

BRKCOM-1001

Stateless Computing

Hardware Abstraction

Service Profiles

Just-in-time Provisioning

Unified Fabric

Consolidated I/O

UCS Manager

Single Management Domain

Virtual Adapters

Virtualised I/O

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Stateless Computing

Hardware State Abstraction: Enhanced server availability


LAN

SAN

UUID: 56 4dcd3f 59 5b
MAC : 08:00:69:02:01:FC
WWN: 5080020000075740
Boot Order: SAN, LAN
Chassis1/Blade-2

Chassis8/Blade-5
BRKCOM-1001

LAN

SAN

Same identity
moved
Chassis1/Blade-2 UUID: 56 4dcd3f 59 5b
MAC : 08:00:69:02:01:FC
WWN: 5080020000075740
Boot Order: SAN, LAN

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Chassis8/Blade-5

Service Profiles
Benefits

Server Name
Server Name
UUID
UUID
MAC
MAC
WWN
WWN
Boot
info
Boot
info
LAN Config
LAN
Config
SAN
Config
SAN Config

UUID, MAC,WWN
Boot info
LAN, SAN Config
Firmware

Consistent and simplified server


deployment
Pre provisioning
Repurposing
Disaster Recovery

Run-time association

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Unified Fabric
Consolidated I/O
LAN

LAN

SAN A

LAN

SAN B

SAN B

SAN A

MGMT

MGMT

160 blades
160 blades

Chassis
1

Chassis
2

Chassis
4

Chassis
3

Chassis
10

Chassis
1/2

Chassis
3/4

Chassis
5/6

Chassis
7/8

Chassis
19/20

Chassis

10

Chassis

10

Network Devices

20

Network Devices

Chassis Management
Devices

20

Chassis Management
Devices

Convergence inside each chassis

True FCoE of LAN/SAN & MGMT

Legacy Blade Vendors


BRKCOM-1001

UCS
Cisco Confidential Internal Use Only

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS Manager: Single Management Domain


Multi-Chassis Server Identity Manager (VCEM)

Fabric Interconnect A

Fabric Interconnect B

Server Health Monitoring (SIM)


Multi-chassis Server Identity Manager
Enet Switch
FC Switch
CMC/OA

Enet Switch
FC Switch

Enet Switch
FC Switch

CMC/OA
LegacyCMC/OA
Blade Architecture

Enclosure 1: Servers 1-16

Enet Switch
FC Switch

Ethernet

Ethernet

Fiber Channel

Fiber Channel

Enclosure 2: Servers 17-32

Enet Switch
FC Switch

Enet Switch
FC Switch

Enet Switch
FC Switch

CMC/OA

CMC/OA

CMC/OA

CMC/OA

Enclosure 4: Servers 49-64

Enet Switch
FC Switch

Enet Switch
FC Switch

Enet Switch
FC Switch

Enet Switch
FC Switch

CMC/OA

CMC/OA

CMC/OA

CMC/OA

Enclosure 5: Servers 65-80

Blade & Chassis Management

CMC/OA

Enet Switch
FC Switch

Enclosure 3: Servers 33-48

Server Health Monitoring

Enclosure 6: Servers 81-96

Servers 1-8

Servers 9-16

Servers 17-24

Servers 25-32

Servers 33-40

Servers 41-48

Servers 49-56

Servers 57-64

Servers 65-72

Servers 73-80

Enet Switch
FC Switch

Enet Switch
FC Switch

Enet Switch
FC Switch

Enet Switch
FC Switch

Servers 81-88

Servers 89-96

CMC/OA

CMC/OA

CMC/OA

CMC/OA

Servers 97-104

Servers 105-112

Servers 113-120

Servers 121-128

Enclosure 7: Servers 97-112

Enclosure 8: Servers 113-128

Enet Switch
FC Switch

Enet Switch
FC Switch

Enet Switch
FC Switch

Enet Switch
FC Switch

Servers 129-136

Servers 137-144

CMC/OA

CMC/OA

CMC/OA

CMC/OA

Servers 145-152

Servers 153-160

Enclosure 9: Servers 129-144


BRKCOM-1001

Enclosure 10: Servers 145-160


2013 Cisco and/or its affiliates. All rights reserved.

Logical Chassis 1
Cisco Public

UCS Manager: Single Management Domain


SAN A
(Rack) Mgmt
LAN
SAN B

All of the benefits of blades applied to rack servers


Single point of management
Firmware management

Service profiles stateless agility

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS Manager: Multi-Domain Management


Do It Yourself

SDK & Emulator

Open Source

Cisco Product

ISV Partners

UCS Central

System Centre plug-in

GoUCS

Cisco CIAC

BMC Integration

PowerShell & .NET

Cisco NSM

CA integration etc

Most flexible

Flexible

Multi-vendor support

Most powerful

Leverage power
of community

Cisco support and


roadmap

Incumbency

Broadest use cases

UCS Dashboard

Multi-UCS Management Solutions


UCS XML API

UCS XML API

UCS XML API

BRKCOM-1004 Automating UCS for Systems Administrators


BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS XML API

Cisco UCS Virtual Interface Card


Creates multiple x16 PCIe Ethernet and FC
interface adapters

UCS 2208 IOM

UCS 2208 IOM

Fabric Failover

Centralised management of virtual interfaces from


UCS Manager
Side B

Side A

Offers Virtualisation aware networking with best


performance (VM-FEX)
vNICs
/vHBAs

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Eth UCS 1280 VIC / 1240 + Exp


FC
FC
Eth

Cisco Public

256

VM-FEX (Vmware ESX, RHEL KVM and


Hyper-V )
Emulated Mode

Each VM gets a dedicated PCIe


device
12%-15% CPU performance
improvement
Appears as distributed virtual
switch to hypervisor
vMotion supported

PCIe Pass-Thru or
VMDirectPath
Co-exists with Standard mode
Bypasses Hypervisor layer
30% improvement in I/O
performance

Appears as distributed virtual


switch to hypervisor
Currently supported with ESX
5.0+ Hyper-V 2012, RHEL KVM
6.3
vMotion supported

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Hardware Overview

Unified Ports
Customer benefits
Simplify fabric purchase by removing port ratio
estimates
Increase design flexibility
Unified Port

Feature details
Flexibility to configure any port at Ethernet (1/10
Gigabit with SFP+) or FCoE or Native FC Ports
(8/4/2/1G with FC Optics)
All ports on UCS 6200 Series
16-port expansion module (E16UP)
Uses existing Ethernet / Fibre Channel SFP and
SFP+ transceiver
Compared to 6100 Series, Fibre Channel is
standard. No requirement to buy FC module

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Native Fibre Channel

Cisco Public

Lossless Ethernet:
1/10GbE, FCoE, iSCSI,
NAS

UCS 6248 Fabric Interconnect

32 x Fixed ports: 1/10 GE or 1/2/4/8


FC
Fabric Interconnect
Cluster Connectivity

Console

Expansion Module (GEM)

Out of Band Mgmt


10/100/1000

Fan Module

Fan Module

N + N Redundant Fans
BRKCOM-1001

Rear Panel

2013 Cisco and/or its affiliates. All rights reserved.

Front Panel

Power Entry

Power Entry

N + N Power Supplies
Cisco Public

UCS FI 6296 Rear Panel


Expansion Module

Expansion Module

Expansion Module

48 x Fixed ports 1/10 GE or 1/2/4/8 FC


BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS FI 6296 Front Panel


Fabric Interconnect

Power Entry

Power Entry

Out of Band Mgmt


10/100/1000

Fan Module

Console

Fan Module

Fan Module

N + 1 Redundant Fans

N + N Power Supplies
BRKCOM-1001

USB Flash

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Fan Module

UCS 5108 Blade Chassis


Up to 8 half slot blades
Up to 4 full slot blades
4x power supplies, N+N grid
redundant
8x fans included
2x UCS Fabric Extender
All items hot-pluggable

AC / DC

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS 5108 Blade Chassis Parts


Rear
6U, 19 Rack

2 Fabric Extenders
(I/O modules)
8 Fan Modules
4 Power
Connectors

Front
6U, 19 Rack

4 to 8 Blades
4 Power
Supplies

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS 5108 Blade Chassis Backplane


Blade Connectors

I/O Modules

PSU Connectors

Redundant data ( 40 G) and management


paths.
BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS 2204/2208 Fabric Extender (I/O Module)


Connects UCS blade chassis to the Fabric Interconnect
10 Gigabit Ethernet, FCoE capable, SFP+ ports
Up to 2 Fabric Extenders per chassis for redundancy

Up to 160 Gbps of bandwidth per chassis


Built-in chassis management functionality

Fully managed by UCS Manager through Fabric Interconnect


No local switching

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Compute Serves : B series


RAS and Performance
Optimised

UCS B440 M2
UCS B230 M2
Database
Consolidation
Virtualisation

UCS B420 M3

Database and
Virtualisation

Mission Critical
Scale-Out
UCS B22 M3

UCS B200 M3

Virtualisation, VDI,
database, ERP and
CRM

Performance
Optimised

IT/Web Infrastructure,
distributed database, ERP and
CRM

Enterprise Class
Web/IT Infrastructure
Proxy/Caching

BRKCOM-1001

Price / Performance Optimised

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Compute Servers : C-Series


UCS C460 M2

RAS and Performance


Optimised

UCS C260 M2

UCS C420 M3
UCS C240 M3

Scale-Out

UCS C220 M3
Virtualisation,
Database and highend HPC

UCS C24 M3
UCS C22 M3
Distributed DB
Middleware
Collaboration
Big Data
Storage Server

Web/IT Infrastructure
Proxy/Caching
BRKCOM-1001

Mission Critical
Performance
Optimised

Data Warehouse
Middleware
Collaboration
Big Data

Enterprise Class
Price / Performance Optimised
2013 Cisco and/or its affiliates. All rights reserved.

Database
Consolidation
Virtualisation

Cisco Public

Database
Consolidation
Virtualisation

Virtualisation Interface Card 1200


B series:1280,1240
C series:1225,P81E
Host connectivity PCIe Gen2 x16
HW Capable of 256 PCIe devices
OS restriction apply

PCIe virtualisation OS independent (same


as M81KR)
Fabric Failover supported
B series Upto Dual 4x10 GE port-channels
to a single server slot
BRKCOM-1005 UCS Architecture Overview
BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Ethernet Connectivity

Block Diagram: Upstream


UCS 6248

UCS 6248
Fabric
Interconnects

IO Modules

16x SFP+

16x SFP+

Expansion Module

2208XP

16x SFP+

16x SFP+

2208XP

Midplane

Mezzanine

1280 VIC
x16 Gen 2

x16 Gen 2

Server Blade

IOH

CPU

CPU

UCS Blade Chassis

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Expansion Module

Switching Modes: End Host


LAN

Spanning
Tree

FI A
vEth 3

vEth 1
VLAN 10

Fabric A

MAC
Learning

MAC
Learning

L2
Switching
VNIC 0

VNIC 0

Server 1

Server 2

BRKCOM-1001

UCS connects to the LAN like a server, not like a switch


Server vNIC pinned to an uplink port
No Spanning Tree Protocol
Reduces control plane load on FI
Simplified upstream connectivity
Maintains MAC table for servers only

Eases MAC table sizing in the access layer


Allows multiple active uplinks per VLAN
Doubles effective bandwidth vs STP
Prevents loops by preventing uplink-to-uplink switching
Completely transparent to upstream LAN
Traffic on same VLAN switched locally

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

End Host Mode : Pinning


Dynamic pinning
Server ports pinned to an uplink
port/port-channel automatically

Static pinning

FI A

Specific ping groups created and


associated with adapters

vEth 3

vEth 1

VNIC 0

VNIC 0

Server X

Oracle

2013 Cisco and/or its affiliates. All rights reserved.

Pinning

Switching

Fabric A

Static pinning allows traffic


management, if required for
certain applications/servers

BRKCOM-1001

DEFINED:
PinGroup
Oracle

Cisco Public

APPLIED:
PinGroup
Oracle

End Host Mode: Upstream Connectivity


With vPC

Without vPC
7K/5K1

7K/5K 2
keep alive

vPC peer-link
PO

EHM

PO

FI A

VNIC 0

EHM
VNIC 0

Server 1

BRKCOM-1001

PO

PO

vPC

FI B

EHM

FI A

VNIC 0

Server 2

Server 1
2013 Cisco and/or its affiliates. All rights reserved.

vPC

EHM
VNIC 0

Server 2
Cisco Public

FI B

End Host Mode: Disjoint Layer 2 Networks


Customer benefits
Ability to support multiple layer 2 disjoint networks
upstream to UCS in End Host Mode
Feature details
Static or dynamic vNIC pinning based on VLAN
membership of the uplink
A VLAN can exist only in one L2 disjoint network,
i.e. no overlap
A vNIC is mutually exclusive to a L2 network
upstream, i.e. a L2 network per vNIC
More than two L2 disjoint networks supported per
host with virtual interface card

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Production
Vlan 10,20

Public
Vlan 31,32

End
Host

Cisco Public

End
Host

Backup
Vlan 40,41

Switch Mode
Fabric Interconnect behaves like a normal Layer 2 switch
Spanning tree protocol is run on the uplink ports per VLAN
MAC learning/aging happens on both the server and uplink ports like in
a typical Layer 2 switch

Was required for certain Application Specific Scenarios


Disjoint VLAN
Direct connect Appliance

Microsoft Load Balancing Clusters

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Block Diagram: FEX 2204


UCS 6248

UCS 6248
Fabric
Interconnects

16x SFP+

16x SFP+

Expansion Module

16x SFP+

16x SFP+

Expansion Module

4 X Network Interface (NIF)


IOM A to FI A
IOM B to FI B
Equal Number of uplinks
IO Modules

2204XP

2204XP

16 X Host Interface (HIF)


16Downlinks

Midplane

Mezzanine

Mezz Card
x16 Gen 2

x16 Gen 2

Server Blade

IOH

CPU

CPU

UCS Blade Chassis

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Block Diagram: FEX 2208


UCS 6248

UCS 6248
Fabric
Interconnects

16x SFP+

16x SFP+

Expansion Module

16x SFP+

16x SFP+

Expansion Module

8 x Network Interface (NIF)


IO Modules

2208XP

2208XP

Host Interface (HIF)


32 Downlinks

Midplane

Mezzanine

Mezz Card
x16 Gen 2

x16 Gen 2

Server Blade

IOH

CPU

CPU

UCS Blade Chassis

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Block Diagram: FEX


UCS 6200

UCS 6200
Fabric
Interconnects

16x SFP+

16x SFP+

Expansion Module

16x SFP+

16x SFP+

Expansion Module

Network Interfaces (NIF) to FI


IO Modules

220X XP

220X XP

Host Interface (HIF) to blades

Midplane

Mezzanine

Server Blade

UCS Blade Chassis

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS 2200 : Discrete Mode (Pinning)


Server slots pinned to uplink
slot 1
slot 2
slot 3
slot 4
slot 5
slot 6
slot 7
slot 8

slot 1
slot 2
slot 3
slot 4
slot 5
slot 6
slot 7
slot 8

slot 1
slot 2
slot 3
slot 4
slot 5
slot 6
slot 7
slot 8

F
E
X

F
E
X

F
E
X
BRKCOM-1001

1 link
NIF

2 links

Fabric Interconnect

Uplink: slots 1,2,3,4,5,6,7,8

Fabric Interconnect

Uplink 1: slots 1,3,5,7


Uplink 2: slots 2,4,6,8

NIF

4 links

Fabric Interconnect

NIF

2013 Cisco and/or its affiliates. All rights reserved.

Uplink 1: slots 1,5


Uplink 2: slots 2,6
Uplink 3: slots 3,7
Uplink 4: slots 4,8

Cisco Public

UCS 2208 : Discrete Mode (Pinning)


Server slots pinned to uplink
slot 1
slot 2
slot 3
slot 4
slot 5
slot 6
slot 7
slot 8

8 links

F
E
X

Fabric Interconnect
NIF

Uplink 1: slot 1
Uplink 2: slot 2
Uplink 3: slot 3
Uplink 4: slot 4
Uplink 5: slot 5
Uplink 6: slot 6
Uplink 7: slot 7
Uplink 8: slot 8

No discrete mode support with 3,5,6,7 uplinks

Adding more links was disruptive

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS 2200 :Port Channel

FI 6200

FI 6200

Customer benefits
Resilience and flexibility

80 Gb

80 Gb

Port-Channel

Feature details
Up to 8 * 10 Gb aggregated bandwidth to each
fabric in a chassis
Port-channel is a user configurable choice,
default mode discrete
Addition of links does not require chassis reacknowledge
Supported number of links in a port-channel:
1,2,3,4,5,6,7 or 8
Load balancing

2208
FI 6200

FI 6200

40 Gb

40 Gb

Port-Channel

2204
BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

UCS 2200 :Port Channel


Server slots channelled across
all uplinks

slot 1
slot 2
slot 3
slot 4
slot 5
slot 6
slot 7
slot 8

slot 1
slot 2
slot 3
slot 4
slot 5
slot 6
slot 7
slot 8

4 links

F
E
X

Fabric Interconnect
NIF

8 links

F
E
X

BRKCOM-1001

Fabric Interconnect
NIF

2013 Cisco and/or its affiliates. All rights reserved.

Uplink 1: slots 1-8


Uplink 2: slots 1-8
Uplink 3: slots 1-8
Uplink 4: slots 1-8

Server slots channelled across


all uplinks
Uplink 1: slots 1-8
Uplink 2: slots 1-8
Uplink 3: slots 1-8
Uplink 4: slots 1-8
Uplink 5: slots 1-8
Uplink 6: slots 1-8
Uplink 7: slots 1-8
Uplink 8: slots 1-8
Cisco Public

UCSM C-series Integration (Nexus 2232)


UCS 2.1 and CIMC release
1.4(6) Required for VIC 1225

UCS 6100 or 6200

Default CIMC Settings

Nexus 2232

Shared-LOM-EXT
Dual Wire Mode still supported
Multiple VIC 1225 supported

GE LOM

PCIe Adapter

CIMC

OS or Hypervisor

C240, C260, C420, C460


NO Direct FI SUPPORT

Mgmt Traffic
Data Traffic
(LAN and FCoE)

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Block Diagram: Fabric Failover


UCS 6248

UCS 6248
Fabric
Interconnects

IO Modules

16x SFP+

16x SFP+

Expansion Module

2208XP

16x SFP+

16x SFP+

2208XP

Midplane

Mezzanine

1280 VIC

Fabric Failover
Server Blade
vNIC
UCS Blade Chassis

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Expansion Module

End Host Mode: Fabric Failover for Ethernet


Fabric provides NIC failover capabilities
when defining a service profile
Traditionally done using NIC bonding
driver in the OS

Provides failover for both unicast and


multicast traffic

UCS 6248

UCS 6248
16x
SFP+

16x
SFP+

2208XP

Expansion
Module

16x
SFP+

16x
SFP+

2208XP

Works for any OS on bare metal

Recommended in case of bare metal OS


Hyper - V

1280 VIC

vNIC
UCS Blade Chassis

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Expansion
Module

Block Diagram: VIC Adapter Port Channel


UCS 6200

UCS 6200
Fabric
Interconnects

16x SFP+

IO Modules

16x SFP+

Expansion Module

16x SFP+

2200

16x SFP+

Expansion Module

2200

Midplane

Mezzanine

1200 VIC

Server Blade

4x10 Gbps Ether channel from VIC 1200 to 2208 IO Modules


2 x 10 Gbps Ether channel from VIC 1200 to 2204 IO Modules
No user configuration required
vNIC flows are Load Balanced across links
Each individual flow limited to 10Gb
Fabric Failover available

1. 10 Gb FTP traffic
2. 10 Gb UDP traffic
BRKCOM-1001

UCS Blade Chassis

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Block Diagram: VM-FEX


UCS 6200

UCS 6200
Fabric
Interconnects

IO Modules

16x SFP+

16x SFP+

Expansion Module

16x SFP+

2200XP

16x SFP+

Expansion Module

2200XP

Midplane

Mezzanine

1280 VIC
x16 Gen 2

VM-FEX

x16 Gen 2

Server Blade

UCS Blade Chassis

BRKCOM-2003
UCS Networking
- Deep
Dive includingCiscoVM-FEX
Public
BRKCOM-1001
2013 Cisco and/or its affiliates.
All rights reserved.

Storage Connectivity

SAN End Host NPV Mode


N-Port Virtualisation Forwarding
SAN A

Fabric Interconnect operates in N_Port Proxy mode

Simplifies multi-vendor interoperation

SAN B

Simplifies management
FLOGI
FDISC

NPIV

SAN switch sees Fabric Interconnect as an FC End


Host with many N_Ports and many FC IDs assigned

NPIV
F_Port

F_Port
VSAN 101
N_Proxy
FI-A

Server facing ports function as F-proxy ports

VSAN 201
N_Proxy
FI-B

vFC 1

vFC 2

F_Proxy

vFC 1

vFC 2

F_Proxy

Server vHBA pinned to an FC uplink in the same


VSAN. Round Robin selection
Provides multiple FC end nodes to one F_Port off an
FC Switch
Eliminates the FC domain on UCS Fabric Interconnect

N_Port
vHBA 0

N_Port
vHBA 1

vHBA 0

One VSAN per F_port (multi-vendor)


vHBA 1

Server 1

Server 2

VSAN 1

VSAN 1

BRKCOM-1001

F_Port Trunking and Channelling with MDS, 5K

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

SAN End Host NPV Mode


N-Port Virtualisation Forwarding with MDS, Nexus 5000

F_ Port
Channel & Trunk

SAN A

SAN B

NPIV

NPIV

F_Port Channelling and Trunking from MDS or Nexus


5000 to UCS

FC Port Channel behaves as one logical uplink

F_Port

FC Port Channel can carry all VSANs (Trunk)

VSAN
201,202

VSAN
101,102

UCS Fabric Interconnects remains in NPV end host


mode

N_Proxy
FI-A

FI-B
vFC 1

vFC 2

vFC 1

vFC 2

Server vHBA has access to bandwidth on any link


member of the FC Port Channel

F_Proxy

Load balancing based on FC Exchange_ID per flow

N_Port
vHBA 0

Server vHBA pinned to an FC Port Channel

vHBA 1

vHBA 0

vHBA 1

Server 1

Server 2

VSAN 1

VSAN 2

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

SAN FC Switch Mode

FC

UCS Fabric Interconnect behaves like an FC fabric


switch
Storage ports can be FC or FCoE

N_Port

SAN

FCoE

MDS
VSAN 2

VSAN 1

TE_Port

Ethernet and FC switching modes are independent


Local Zoning OR Upstream Zoning
Parallel Local and Upstream Zoning Currently
NOT Supported
Upstream Zoning Provided by MDS/N5k
Fabric Interconnect uses a FC Domain ID
Supported FC/FCoE Direct Connect Arrays

MDS

F_Port

FI-A FC Switch

FI-B FC Switch

vFC 1

vFC 2

vFC 1

vFC 2

F_Port

N_Port

vHBA 0

vHBA 1

vHBA 0

vHBA 1

Check Note 5 on HCL for Updated List

Lower cost point for small deployments (no


access layer FC/FCoE switches required)
BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Server 1

Server 2

VSAN 1

VSAN 2

Cisco Public

Multi-Hop FCoE
FCoE STORAGE

End-to-End FCoE

MDS, N5K, N7K FCoE Capable


Switches Supported Upstream
New Port Type Unified Uplink

FCoE

FCoE
MDS/N5K/N7K

MDS/N5K/N7K
FCoE/Ethernet

Carries FCoE and Normal Ethernet


Traffic

Unified Uplinks
NPV/EHM
UCS FI

UCS FI

Fabric Interconnect in End Host Mode


or Switch Mode

UCS B-Series

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

FCoE/Ethernet

NAS Direct Attach (Appliance Port)


LAN

NAS

Default (recommended) - End Host


Mode

Volume
A

Volume
B

C1

C2

Superior traffic engineering


Easier integration into network

Appliance
Port

1.4 Introduced Appliance Ports which


allow direct connect NAS filers

FI_A
vEth 1

A
vEth 2

FI-B
vEth 1

U
vEth 2

Options - Ethernet Switching Mode


As of 1.4, no need to use this mode for
NAS direct connect
Previous releases required switching
mode for direct connect NAS
BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

vNIC
0

vNIC
1

vNIC
0

vNIC
1

Server 1

Server 2

Accessing
Volume A

Accessing
Volume B

Cisco Public

Unified Appliance Support


Storage

File and block data over a single


port/cable
FCoE, iSCSI, NFS, CIFS

FCoE
iSCSI
NFS
CIFS

Unified Appliance Port

Port and cable consolidation

New port type: Unified Appliance Port

UCS FI

UCS FI

Appliance port of today + FCoE

Initial support for NetApp storage and


their Unified Target Adapter
UCS B-Series

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

58

iSCSI Boot
An alternative boot option for stateless servers

iSCSI Boot Support


Cisco UCS Virtual Interface Card (M81KR )
Cisco UCS M51KR-B Broadcom BCM5771

Option ROM uses iSCSI Boot Firmware Table (iBFT)


iSCSI Hardware Offload is not a requirement to support booting, only
supporting in the option ROM

BRKCOM-2002 UCS Supported Storage Architectures


BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Demo / Basic Configuration Steps

UCS Configuration Workflow


Physical
Base Configuration
Network Configuration
Storage Configuration
Server Configuration
BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Topology
ETH 1

SAN A

ETH 2

SAN B

VLAN 10
VLAN 1000

VSAN
101, 102

32

VSAN
201, 202

31

30

29

FI A
1

I
O
M

L1 L1

29

30

I
O
M

I
O
M

Chassis 2

CNA1

2013 Cisco and/or its affiliates. All rights reserved.

I
O
M

Server-01
BRKCOM-1001

32

FI B

L2 L2

Chassis 1

31

Cisco Public

Console setup : Fabric Interconnect A


You have chosen to setup a new Fabric interconnect. Continue? (y/n): y
Enforce strong password? (y/n) [y]:
Enter the password for "admin": <password>
Confirm the password for "admin": <password>
Is this Fabric interconnect part of a cluster(select 'no' for standalone)? (yes/no) [n]: y
Enter the switch fabric (A/B) []: a
Enter the system name: <UCS Domain name>
Physical Switch Mgmt0 IPv4 address : <FI A IP>
Physical Switch Mgmt0 IPv4 netmask : <MASK>
IPv4 address of the default gateway : <Gateway>
Cluster IPv4 address : <CLUSTER IP>
Configure the DNS Server IPv4 address? (yes/no) [n]:
Configure the default domain name? (yes/no) [n]:

Following configurations will be applied:


Switch Fabric=A
System Name= UCS Domain name
Enforced Strong Password= no
Physical Switch Mgmt0 IP Address= FI A IP
Physical Switch Mgmt0 IP Netmask= MASK
Default Gateway= GATEWAY
Cluster Enabled= yes
Cluster IP Address= IP
NOTE: Cluster IP will be configured only after both Fabric Interconnects are initialized
Apply and save the configuration (select 'no' if you want to re-enter)? (yes/no):
Applying configuration. Please wait.
Configuration file Ok
Cisco UCS 6200 Series Fabric Interconnect
<UCS Domain name>-A login:

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Console setup : Fabric Interconnect B


Enter the configuration method. (console/gui) ? console
Installer has detected the presence of a peer Fabric interconnect. This Fabric interconnect will be added
to the cluster. Continue (y/n) ? y
Enter the admin password of the peer Fabric interconnect:
Connecting to peer Fabric interconnect... done
Retrieving config from peer Fabric interconnect... done
Peer Fabric interconnect Mgmt0 IP Address: <FI A IP >
Peer Fabric interconnect Mgmt0 IP Netmask: <FI A MASK>
Cluster IP address
: <CLUSTER IP>
Physical Switch Mgmt0 IPv4 address : <FI B IP>

Apply and save the configuration (select 'no' if you want to re-enter)? (yes/no): yes
Applying configuration. Please wait.
Configuration file - Ok

Cisco UCS 6200 Series Fabric Interconnect


<UCS Domain name>-B login:

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Configuration overview
Basic Configuration
1. Configure Chassis Discovery and Power Policy

2. Configure Unified Ports


3. Configure Server ports for Chassis Discovery
4. Configure Management IP (KVM)

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Configuration overview
Network Configuration
1. Configure network uplink ports

2. Configure Port Channel


3. Configure VLAN (Dev 10, Dev-Clu-1000 )

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Configuration overview
Storage Configuration
1. Enable FC trunking

2. Configure VSAN (A:101,102 B:201,202)


FCOE VLAN id not used as a data vlan
3. Configure storage uplink ports

4. Configure Port Channel

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Configuration overview
Service Profile
1. Service Profile Experts Wizard

2. UUID settings
3. vNIC settings
4. vHBA settings

5. Boot settings
6. Associate blade
7. Install OS

BRKCOM-2001 UCS Management Architecture - Deep Dive


BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

More UCS sessions


Date
Session
Wednesday
BRKCOM-1005
Thursday
BRKCOM-1004
BRKCOM-2002
BRKCOM-2003
BRKCOM-2008
Friday
BRKCOM-2001
BRKCOM-3001

BRKCOM-1001

Title
UCS Architecture Overview
Automating UCS for Systems Administrators
UCS Supported Storage Architectures
UCS Networking - Deep Dive including VM-FEX
UCS Firmware Management Architecture
UCS Management Architecture - Deep Dive
Troubleshooting the Cisco UCS Compute Deployment

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

Q&A

Complete Your Online Session


Evaluation
Complete your session evaluation:
Directly from your mobile device by
visiting
www.ciscoliveaustralia.com/mobile and
login by entering your username and
password
Visit one of the Cisco Live internet
stations located throughout the venue

Open a browser on your own computer


to access the Cisco Live onsite portal Dont forget to activate your Cisco Live 365 account

for access to all session material, communities, and


on-demand and live activities throughout the year.
Activate your account by visiting
www.ciscolive365.com

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

71

BRKCOM-1001

2013 Cisco and/or its affiliates. All rights reserved.

Cisco Public

You might also like