P-VIP Replacement Lamps

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 1

P-VIP Replacement Lamps Agenda

P-VIP and VIP after sales lamps


General description
New after sales lamps
Existing after sales lamps
Instruction for use

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 2

P-VIP MD TV Replacement Lamps

DO DIS

Lamp type

Cat.

Box
size,
pcs.

P-VIP 100-120/1.3 E23ha

TV

50

4008321 194 909

518 59A 002G

P-VIP 100-120/1.0 P22ha

TV

50

4008321 194 923

518 62F 002G

P-VIP 120-132/1.0 P22ha

TV

50

4008321 194 947

518 63B 002G

P-VIP 120-132/1.0 E22ha

TV

50

4008321 126 641

482 47E01HM

P-VIP 100-120/1.0 E22ha

TV

50

4008321 221 582

535 073 002G

P-VIP 100-120/1.0 E23ha

TV

50

4008321 221 568

535 05B 002G

P-VIP 100-120/1.3 E23a

TV

50

4008321 901323

542 930 002G

P-VIP 132-150/1.0 E22ha

TV

50

4008321 244260

542 94D 002G

P-VIP 132-150/1.0 E23ha

TV

50

4008321 244284

542 959 002G

P-VIP 100-120/1.3 P23a

TV

50

4008321 243614

541 559 0187

P-VIP Replacement Lamps,


Subject to alteration
Page: 3

EAN 10 (1pcs)

IC

P-VIP FP Replacement Lamps

DO DIS

Lamp type

Cat.

Box
size,
pcs.

P-VIP 150/1.0 P21.5a

FP

50

4008321 228666

538 118 002G

VIP R 120/P12a

FP

60

4008321 195 067

518 694 002G

VIP R 120/P16a

FP

50

4008321 194 985

518 653 002G

VIP R 150/P16a

FP

50

4008321 195 005

518 661 002G

P-VIP 150/1.3 E21.5a

FP

50

4008321 194 961

518 647 002G

VIP R 150/P22a

FP

50

4008321 195 029

518 67C 002G

P-VIP 180/1.0 E20a

FP

50

4008321 195 081

518 700 002G

P-VIP 200/1.0 P21.5a

FP

50

4008321 195 043

518 688 002G

P-VIP 200/1.0 E17.5a

FP

60

4008321 242235

544 77A 002G

P-VIP 200/1.0 E19a

FP

60

4008321 195 104

518 71D 002G

P-VIP 250/1.3 E21.8a

FP

50

4008321 257 291

A54256C002G

P-VIP Replacement Lamps,


Subject to alteration
Page: 4

EAN 10 (1pcs)

IC

P-VIP Replacement Lamps Agenda

P-VIP and VIP after sales lamps


General description
New after sales lamps
Existing after sales lamps
Instruction for use

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 5

P-VIP Replacement Lamps Advantages

Supreme efficiency P-VIP and VIP lamps


Highest quality meeting the strict quality demands of
the CE and IT industries
From leading player in the market

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 6

P-VIP Technical Aspects

Technology

Discharge lamps with Mercury-halogen gas

Lamp power

100 250 W AC

Lumen yield

> 60 lm / W

Pressure

cold lamp: 100 mbar


hot lamp: up to 250 bar

Burner temperature

operating: up to 1200 C
typical cool down < 5 min.

Pre-materials
Burner
Reflector

Glass:

ultra pure quartz glass

Electrodes:

Tungsten

Glass, coated with dichroic mirror

a) Valid for P-VIP and VIP R lamps


DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 7

P-VIP Lamp Naming

P-VIP 150/1.3 E21.5ha


Aftermarket

Professional
Video Projection
high performance
discharge lamp

Extra Info
h: 15 kV ignition

Reflector size

Lamp power
Electrode gap
DO DIS

Reflector shape
Elliptical or Parabolic

P-VIP Replacement Lamps,


Subject to alteration
Page: 8

P-VIP Lamp Naming

VIP R 150 / P16a


Video Projection
high performance
discharge lamp

After market

Reflector
Lamp power

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 9

Reflector shape
and size

P-VIP Replacement Lamps Agenda

P-VIP and VIP after sales lamps


General description
New after sales lamps
Existing after sales lamps
Instruction for use

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 10

Lamp P-VIP 120-132/1.0 E22ha

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

MD TV
E22 elliptic
1.0 mm
120 132 W
15 18 kV
5,900 lm @ 132 W
> 6,000 h @ 132 W
Complies RoHS

a) observed in working distance through 6 mm aperture


b) when operated on OSRAM lamp driver PT VIP 01 RP

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 11

Lamp P-VIP 120-132/1.0 E22ha


Contour

Lamp design

E22 elliptic

working distance 34.0 mm

Reflector glass

front glass yes

borosilicate

air inlets tooled air gaps


location contact 1a central at base
location contact 2a 04:00 oclock

Top

Glass air
guides
not to scale

View from Rear


70

F2
65
30

A = reference edge
Dimensions in mm

DO DIS

34.0
A

P-VIP Replacement Lamps,


Subject to alteration
Page: 12

< 85.0

Lamp P-VIP 100-120/1.3 E23a

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

MD TV
E23 elliptic
1.3 mm
100 120 W
5 7 kV
5,200 lm @ 120 W
> 6,000 h @ 120 W
Complies RoHS

a) observed in working distance through 6 mm aperture


b) when operated on OSRAM lamp driver PT VIP 2AC/380 O1

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 13

Lamp P-VIP 100-120/1.3 E23a

Contour

Lamp design

E23 elliptic

working distance 52.0 mm

Reflector glass

front glass yes

borosilicate

air inlets no, lamp closed


location contact 1a central at base
location contact 2a 03:00 oclock
a) viewed from front

dimensions in mm

top
95.0

front view
F2

52.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 14

< 88.0

Lamp P-VIP 132-150/1.0 E22ha

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

MD TV
E22 elliptic
1.0 mm
132 150 W
15 18 kV
6,500 lm @ 150 W
6,000 h @ 150 W
Complies RoHS

a) observed in working distance through 6 mm aperture


b) when operated on OSRAM lamp driver PT VIP 01 RP

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 15

Lamp P-VIP 132-150/1.0 E22ha


Contour

Lamp design

E22 elliptic

working distance 34.0 mm

Reflector glass

front glass yes

borosilicate

air inlets tooled air gaps


location contact 1a central at base
location contact 2a 04:00 oclock

Top

Glass air
guides
not to scale

View from Rear


70

F2
65
30

A = reference edge
Dimensions in mm

DO DIS

34.0
A

P-VIP Replacement Lamps,


Subject to alteration
Page: 16

< 85.0

Lamp P-VIP 132-150/1.0 E23ha

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

MD TV
E23 elliptic
1.0 mm
132 150 W
15 18 kV
6,500 lm @ 150 W
6,000 h @ 150 W
Complies RoHS

a) observed in working distance through 6 mm aperture


b) when operated on OSRAM lamp driver PT VIP O1RP

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 17

Lamp P-VIP 100-120/1.0 E23ha

Contour

Lamp design

E23 elliptic

working distance 52.0 mm

Reflector glass

front glass yes

borosilicate

air inlets no, lamp closed


location contact 1a central at base
location contact 2a 03:00 oclock
a) viewed from front

dimensions in mm

top
95.0

front view
F2

52.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 18

< 88.0

Lamp P-VIP 100-120/1.3 P23a

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

a)
b)

DO DIS

MD TV
P23 parabolic
1.3 mm
100 120 W
15 18 kV
4,400 lm @ 120 W
6,000 h @ 120 W
Complies RoHS

observed in 900 mm distance through 95 mm aperture


when operated on OSRAM lamp driver PT VIP 2AC/380 O1
P-VIP Replacement Lamps,
Subject to alteration
Page: 19

Lamp P-VIP 100-120/1.3 P23a

Contour

Lamp design

P23 parabolic

working distance infinite

Reflector glass

front glass yes

borosilicate

air inlets no
location contact 1a central at base
location contact 2a 04:30 oclock
a) viewed from front

dimensions in mm
Max. 96.0

top
front view

< 82.0
< 92.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 20

Lamp P-VIP 200/1.0 E17.5a

 Category
 Reflector
 Arc gap
 Rated power
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

a)
b)
DO DIS

FP
E17.5 elliptic
1.0 mm
200 W
16 kV
6,300 lm @ 200 W
2,000 h @ 200 W
Complies RoHS

observed in working distance through 5.0 x 3.8 mm2 rectangular


aperture
when operated on OSRAM lamp driver PT VIP 3 AC/380 O3
P-VIP Replacement Lamps,
Subject to alteration
Page: 21

Lamp P-VIP 200/1.0 E17.5a

Contour

Lamp design

E17.5 elliptic

working distance 39.15 mm

Reflector glass

front glass no
air inletsa no

borosilicate

location contact 1a Side at base


location contact 2a 10:30 oclock
top
dimensions in mm
43.0

front view
F2

48.0

DO DIS

a) viewed from front

P-VIP Replacement Lamps,


Subject to alteration
Page: 22

39,15

< 52,0

Lamp P-VIP 250/1.3 E21.8a

 Category
 Reflector
 Arc gap
 Rated power
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

FP
E21.8 elliptical
1.3 mm
250 W
5 kV
8.600 lm @ 250 W
> 2,000 h @ 250 W
Complies RoHS

a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture


b) when operated on OSRAM lamp driver PT VIP 5AC/380 O4

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 23

Lamp P-VIP 250/1.3 E21.8a


Contour

E21.82 elliptical

Lamp design

working distance

36.0 mm

front glass

yes

Reflector glass
Lamp lenght

Cristalized

air inlets

air gaps

67 mm

location contact 1a central at base


location contact 2a 04:00 oclock

61
DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 24

P-VIP Replacement Lamps Agenda

P-VIP and VIP after sales lamps


General description
New after sales lamps
Existing after sales lamps
Instruction for use

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 25

Lamp P-VIP 100-120/1.0 E23ha

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

MD TV
E23 elliptic
1.3 mm
100 120 W
15 18 kV
5,200 lm @ 120 W
> 6,000 h @ 120 W
Complies RoHS

a) observed in working distance through 6 mm aperture


b) when operated on OSRAM lamp driver PT VIP 2AC/380 O1

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 26

Lamp P-VIP 100-120/1.0 E23ha

Contour

Lamp design

E23 elliptic

working distance 52.0 mm

Reflector glass

front glass yes

borosilicate

air inlets no, lamp closed


location contact 1a central at base
location contact 2a 03:00 oclock
a) viewed from front

dimensions in mm

top
95.0

front view
F2

52.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 27

< 88.0

Lamp P-VIP 100-120/1.0 E22ha

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

MD TV
E22 elliptic
1.0 mm
100 120 W
15 18 kV
5,200 lm @ 120 W
> 6,000 h @ 120 W
Complies RoHS

a) observed in working distance through 6 mm aperture


b) when operated on OSRAM lamp driver PT VIP 01 RP

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 28

Lamp P-VIP 100-120/1.0 E22ha


Contour

Lamp design

E22 elliptic

working distance 34.0 mm

Reflector glass

front glass yes

borosilicate

air inlets tooled air gaps


location contact 1a central at base
location contact 2a 04:00 oclock

Top

Glass air
guides
not to scale

View from Rear


70

F2
65
30

A = reference edge
Dimensions in mm

DO DIS

34.0
A

P-VIP Replacement Lamps,


Subject to alteration
Page: 29

< 85.0

Lamp P-VIP 150/1.0 P21.5a

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

FP
P21.5 parabolic
1.0 mm
150 W
5 kV
5,300 lm @ 150 W
1,500 h @ 150 W
Complies RoHS

a) observed in 900 mm distance through 95 mm aperture


b) when operated on OSRAM lamp driver PT VIP 150AC/380 O1

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 30

Lamp P-VIP 150/1.0 P21.5a

Contour

Lamp design

P21.5 parabolic

working distance infinite

Reflector glass

front glass yes

crystallized

air inlets 4 x, on all four sides


location contact 1a 04:30 oclock
location contact 2a 07:30 oclock
a) viewed from front

dimensions in mm
52.0

top
front view

56.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 31

< 73.0

Lamp P-VIP 100-120/1.3 E23ha

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

MD TV
E23 elliptic
1.3 mm
100 120 W
15 18 kV
5,200 lm @ 120 W
> 6,000 h @ 120 W
Complies RoHS

a) observed in working distance through 6 mm aperture


b) when operated on OSRAM lamp driver PT VIP 2AC/380 O1

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 32

Lamp P-VIP 100-120/1.3 E23ha

Contour

Lamp design

E23 elliptic

working distance 52.0 mm

Reflector glass

front glass yes

borosilicate

air inlets no, lamp closed


location contact 1a central at base
location contact 2a 03:00 oclock
a) viewed from front

dimensions in mm

top
95.0

front view
F2

52.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 33

< 88.0

Lamp P-VIP 100-120/1.0 P22ha

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

MD TV
P22 parabolic
1.0 mm
100 120 W
15 18 kV
3,800 lm @ 120 W
> 6,000 h @ 120 W
Complies RoHS

a) observed in 2400 mm distance through 160 mm aperture


b) when operated on OSRAM lamp driver PT VIP 2AC/380 O1

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 34

Lamp P-VIP 100-120/1.0 P22ha

Contour

Lamp design

P22 parabolic

working distance infinite

Reflector glass

front glass yes

borosilicate

air inlets no, lamp closed


location contact 1a central at base
location contact 2a 04:30 oclock
a) viewed from front

dimensions in mm
65.0

top
front view

70.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 35

< 82.0

Lamp P-VIP 120-132/1.0 P22ha

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

MD TV
P22 parabolic
1.0 mm
120 132 W
15 18 kV
4,500 lm @ 132 W
> 6,000 h @ 132 W
Complies RoHS

a) observed in 2400 mm distance through 160 mm aperture


b) when operated on OSRAM lamp driver PT VIP O1 RP 132

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 36

Lamp P-VIP 120-132/1.0 P22ha

Contour

Lamp design

P22 parabolic

working distance infinite

Reflector glass

front glass yes

borosilicate

air inlets 1 x TOP, 1 x BOTTOM


location contact 1a central at base
location contact 2a 04:30 oclock
a) viewed from front

dimensions in mm
65.0

top
front view

70.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 37

< 82.0

Lamp VIP R 120/P12a

 Category
 Reflector
 Arc gap
 Rated power
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

FP
E18 elliptic
1.0 mm
120 132 W
5 kV
4,900 lm @ 132 W
> 3,000 h @ 132 W
Complies RoHS

a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture


b) when operated on OSRAM lamp driver PT VIP 120AC/100-240 Q1

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 38

Lamp VIP R 120/P12a

Contour

Lamp design

E18 elliptic

front glass no

working distance 26.6 mm


borosilicate
Reflector glass

air inlets burner extends over


reflector rim
location contact 1a 10:30 oclock
location contact 2a 01:30 oclock
a) viewed from front

dimensions in mm
43.7

top
front view

48.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 39

< 3.5

F2

26.6

< 45.0

Lamp VIP R 120/P16a

 Category
 Reflector
 Arc gap
 Rated power
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

FP
P16 elliptic
1.0 mm
120 W
20 kV
4,400 lm @ 120 W
>1,500 h @ 120 W
Complies RoHS

a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture


b) when operated on OSRAM lamp driver PT VIP 120AC/100-240 H

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 40

Lamp VIP R 120/P16a

Contour

Lamp design

P16 elliptic

working distance 26.0 mm

Reflector glass

front glass front cap incl. front glass

borosilicate

air inlets 1 x left, 1 x right


HV contacting 70/100 mm leads with plug
attached to lamp
HV plug SMK 101CCT-92-01 male

dimensions in mm
49.7

top
F2
front view

47.8

26.0
< 70.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 41

Lamp VIP R 150/P16a

 Category
 Reflector
 Arc gap
 Rated power
 Ignition
 Light output typ.a
 Aaverage Life timeb
 Environmental

FP
P16 elliptic
1.3 mm
150 W
20 kV
5,200 lm @ 150 W
>3,000 h @ 150 W
Complies RoHS

a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture


b) when operated on OSRAM lamp driver PT VIP 150AC/100-240 H2

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 42

Lamp VIP R 150/P16a

Contour

Lamp design

P16 elliptic

working distance 26.0 mm

Reflector glass

front glass front cap incl. front glass

borosillicate

air inlets 1 x left, 1 x right


HV contacting 70/100 mm leads with plug
attached to lamp
HV plug SMK 101CCT-92-01 male

dimensions in mm
49.7

top
F2
front view

47.8

26.0
< 70.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 43

Lamp P-VIP 150/1.3 E21.5a

 Category
 Reflector
 Arc gap
 Rated power
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

FP
E21.5 elliptic
1.3 mm
150 W
16 kV
5,500 lm @ 150 W
> 2,500 h @ 150 W
Complies RoHS

a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture


b) when operated on OSRAM lamp driver PT VIP 150AC/100-240 H1

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 44

Lamp P-VIP 150/1.3 E21.5a

Contour

Lamp design

E21.5 elliptic

working distance 17.3 mm

Reflector glass

front glass yes


air inletsa slot on left side

borosilicate

location contact 1a central at base


location contact 2a 01:30 oclock
a) viewed from front

top

dimensions in mm
52.0

front view

F2

56.0

< 76.5
17.3

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 45

Lamp VIP R 150/P22a

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

FP
P22 parabolic
1.3 mm
150 W
16 kV
3800 lm @ 150 W
1000 h @ 150 W
Complies RoHS

a) observed in 900 mm distance through 95 mm aperture


b) when operated on OSRAM lamp driver PT VIP 150AC/100-240 H1

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 46

Lamp VIP R 150/P22a

Contour

Lamp design

P22 parabolic

working distance infinite

Reflector glass

front glass yes

borosilicate

air inlets no, lamp closed


location contact 1a central at base
location contact 2a 4:30 oclock
a) viewed from front

dimensions in mm
65.0

top
front view

70.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 47

< 82.0

Lamp P-VIP 180/1.0 E20a

 Category
 Reflector
 Arc gap
 Rated power
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

FP
E20 elliptic
1.0 mm
180 W; Dimm: 156 W
5 kV
6,800 lm @ 180 W
>3,000 h @ 180 W
Complies RoHS

a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture


b) when operated on OSRAM lamp driver PT VIP 180AC/100-240 H1

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 48

Lamp P-VIP 180/1.0 E20a

Contour

Lamp design

E20 elliptic

working distance 26.0

Reflector glass

front glass front cap incl. front glass

borosilicate

air inlets 1 x left, 1 x right


HV contacting 100/100 mm leads with
plug attached to lamp
HV plug SMK 101CCT-92-01 male

dimensions in mm
49.7

top
F2
front view

47.8

26.0
< 70.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 49

Lamp P-VIP 200/1.0 P21.5a

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

FP
P21.5 parabolic
1.0 mm
200 W, Dimm: 160W
5 kV
8,000 lm @ 200 W
1,500 h @ 200 W
Complies RoHS

a) observed in 900 mm distance through 95 mm aperture


b) when operated on OSRAM lamp driver PT VIP 3AC/380 O3

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 50

Lamp P-VIP 200/1.0 P21.5a

Contour

Lamp design

P21.5 parabolic

working distance infinite

Reflector glass

front glass yes

crystallized

air inlets 4 x, on all four sides


location contact 1a 04:30 oclock
location contact 2a 07:30 oclock
a) viewed from front

dimensions in mm
52.0

top
front view

56.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 51

< 73.0

Lamp P-VIP 200/1.0 E19a

 Category
 Reflector
 Arc gap
 Power range
 Ignition
 Light output typ.a
 Average Life timeb
 Environmental

FP
E19 elliptic
1.0 mm
200 W
2.5 5 kV
8,200 lm @ 200 W
2,500 h @ 200 W
Complies RoHS

a) observed in working distance through 5.0 x 3.8 mm2 rectangular aperture


b) when operated on OSRAM lamp driver PT VIP O3 MID 200

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 52

Lamp P-VIP 200/1.0 E19a

Contour

Lamp design

E19 elliptic

working distance 37.7 mm


crystallized
Reflector glass

front glass no
air inlets burner extends over
reflector rim
location contact 1a 10:30 oclock
location contact 2a 01:30 oclock
a) viewed from front

dimensions in mm

46.0

top

F2
rear view

46.0

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 53

< 13.5

37.7

< 42.5

P-VIP Replacement Lamps Agenda

P-VIP and VIP after sales lamps


General description
New after sales lamps
Existing after sales lamps
Instruction for use

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 54

P-VIP Instruction for Use


For lamp replacement
 switch off power,
 disconnect mains supply,
 disconnect power cord,
allow lamp to reach room temperature.

This P-VIP
lamp
operates at high pressure and at high temperature and may
unexpectedly shatter.
generates ultraviolet radiation which may cause skin and
eye irritation with prolonged exposure.
must be operated only in suitably designed, enclosed fixtures which
prevent direct observation of the arc and will prevent lamp fragments
from exiting, in the unlikely event of a lamp rupture.
DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 55

P-VIP Instruction for Use


Do not touch the lamp with bare hands.
If necessary, lamp can be cleaned with lint free towel
before operation.
Protect lamp environment against high ignition pulses
Front projection max. 8 kV and rear projection max. 23 kV
Avoid direct contact of objects to reflector cover glass.
This lamp must not be operated with a broken, cracked
or loose reflector or cover glass.
Fast on-off-cycles will reduce lamp life ( 10 min on/off)
Operate lamp only in accordance with UL 1950 regulations.
Avoid back-reflection of light into burner.
DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 56

P-VIP Instruction for Use

Disposal
For disposal of spent lamps, always consult federal, state, local and
provincial hazardous waste disposal rules and regulations to ensure
proper disposal.

Caution
This lamp emits ultra violet (UV) radiation and operates at high pressure.
This lamp may only be used in enclosed fixtures that comply with
UL1572. Due to the high luminous efficacy, the UV radiation which the
lamp emits and the high pressure within the lamp, P-VIP
lamps may
only be operated within enclosed, purpose-built housings.

DO DIS

P-VIP Replacement Lamps,


Subject to alteration
Page: 57