Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.
Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without
limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or
more additional patents or pending patent applications in the U.S. and in other countries.
This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and
decompilation. No part of the product or of this document may be reproduced in any form by any means without prior written authorization of
Sun and its licensors, if any.
Third-party software, including font technology, is copyrighted and licensed from Sun suppliers.
Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in
the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd.
Sun, Sun Microsystems, the Sun logo, Java, AnswerBook2, docs.sun.com,Sun Blade, and Solaris are trademarks or registered trademarks of Sun
Microsystems, Inc. in the U.S. and in other countries.
All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and in other
countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc.
The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges
the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun
holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Suns licensees who implement OPEN
LOOK GUIs and otherwise comply with Suns written license agreements.
AMD Opteron is a trademark or registered trademark of Advanced Microdevices, Inc.
U.S. Government RightsCommercial use. Government users are subject to the Sun Microsystems, Inc. standard license agreement and
applicable provisions of the FAR and its supplements.
DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, Etats-Unis. Tous droits rservs.
Sun Microsystems, Inc. a les droits de proprit intellectuels relatants la technologie qui est dcrit dans ce document. En particulier, et sans la
limitation, ces droits de proprit intellectuels peuvent inclure un ou plus des brevets amricains numrs
http://www.sun.com/patents et un ou les brevets plus supplmentaires ou les applications de brevet en attente dans les Etats-Unis et
dans les autres pays.
Ce produit ou document est protg par un copyright et distribu avec des licences qui en restreignent lutilisation, la copie, la distribution, et la
dcompilation. Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme, par quelque moyen que ce soit, sans
lautorisation pralable et crite de Sun et de ses bailleurs de licence, sil y en a.
Le logiciel dtenu par des tiers, et qui comprend la technologie relative aux polices de caractres, est protg par un copyright et licenci par des
fournisseurs de Sun.
Des parties de ce produit pourront tre drives des systmes Berkeley BSD licencis par lUniversit de Californie. UNIX est une marque
dpose aux Etats-Unis et dans dautres pays et licencie exclusivement par X/Open Company, Ltd.
Sun, Sun Microsystems, le logo Sun, Java, AnswerBook2, docs.sun.com, Sun Blade, et Solaris sont des marques de fabrique ou des marques
dposes de Sun Microsystems, Inc. aux Etats-Unis et dans dautres pays.
Toutes les marques SPARC sont utilises sous licence et sont des marques de fabrique ou des marques dposes de SPARC International, Inc.
aux Etats-Unis et dans dautres pays. Les produits portant les marques SPARC sont bass sur une architecture dveloppe par Sun
Microsystems, Inc.
Linterface dutilisation graphique OPEN LOOK et Sun a t dveloppe par Sun Microsystems, Inc. pour ses utilisateurs et licencis. Sun
reconnat les efforts de pionniers de Xerox pour la recherche et le dveloppement du concept des interfaces dutilisation visuelle ou graphique
pour lindustrie de linformatique. Sun dtient une license non exclusive de Xerox sur linterface dutilisation graphique Xerox, cette licence
couvrant galement les licencies de Sun qui mettent en place linterface d utilisation graphique OPEN LOOK et qui en outre se conforment
aux licences crites de Sun.
AMD Opteron est une marque de fabrique ou une marque deposee de Advanced Microdevices, Inc.
LA DOCUMENTATION EST FOURNIE "EN LTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT
TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A LAPTITUDE A UNE UTILISATION PARTICULIERE OU A
LABSENCE DE CONTREFAON.
LA DOCUMENTATION EST FOURNIE "EN LTAT" ET TOUTES AUTRES CONDITIONS, DCLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES DANS LA LIMITE DE LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE
GARANTIE IMPLICITE RELATIVE LA QUALIT MARCHANDE, LAPTITUDE UNE UTILISATION PARTICULIRE OU
LABSENCE DE CONTREFAON.
Please
Recycle
Contents
Preface
1.
ix
Introduction
1.1.1
1.1.2
1.2
2.
11
Address Space
2.2
12
1.1.1.1
1.1.1.2
CH Address Space
Components
13
15
16
16
1.2.1
1.2.2
1.2.3
11
16
18
18
21
21
2.1.1
2.1.2
22
24
25
2.2.1
25
2.2.2
25
iii
2.2.3
3.
3.2
4.
5.
31
3.1.2
Privilege Levels
32
3.1.3
31
32
3.1.3.1
Command Verbs
3.1.3.2
Command Options
3.1.3.3
Command Targets
3.1.3.4
Command Properties
Command Syntax
32
33
33
33
34
41
4.1
41
4.2
42
4.2.1
42
4.2.2
4.2.3
4.2.4
42
42
43
4.2.4.1
Syntax
43
4.2.4.2
5.2
27
31
3.1.1
5.1
iv
51
5.1.2
43
51
51
52
5.1.2.1
Syntax
52
5.1.2.2
52
53
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
5.2.1
5.2.2
5.2.3
5.2.2.2
5.5
5.6
55
55
56
58
58
59
61
6.1
6.2
6.3
6.4
61
64
64
64
66
66
7.2
7.3
71
71
72
73
7.3.1
7.3.2
RADIUS
54
55
6.5
53
54
5.4
6.4.1
8.
Syntax
5.7
7.
5.2.2.1
5.3
5.6.1
6.
53
74
74
81
8.1
RADIUS Overview
81
8.2
82
Contents
8.2.1
8.3
9.
RADIUS Commands
83
8.3.1
show /CMM/clients/radius
8.3.2
set /CMM/clients/radius
8.3.3
show /CMM/clients
About SNMP
9.1.1
83
84
85
91
91
91
9.2
9.3
MIBs Integration
9.4
9.5
9.6
92
93
93
94
9.5.1
9.5.2
94
9.6.2
9.6.3
Sensors
94
95
9.6.1
vi
82
10.
RADIUS Parameters
95
95
95
9.6.3.1
Syntax
95
9.6.3.2
9.6.3.3
Examples
96
96
101
Types of Sensors
101
Discrete Sensors
Threshold Sensors
Displaying Sensors
102
103
101
102
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
A.2
A1
A1
A5
A.2.1
A5
A.2.2
A6
A.2.3
A7
A.2.4
A8
A.2.5
A8
A.2.6
A10
A.2.7
A.2.8
A.2.9
A12
A11
A14
A18
A19
A19
B1
Glossary1
Index1
Contents
vii
viii
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Preface
The Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000
Modular System provides instructions for managing the Sun Blade 6000 modular
system chassis using a modified version of the Integrated Lights Out Manager
(ILOM) called the Chassis Management Module (CMM). Throughout this
document, it is referred to as the CMM ILOM.
ix
Shell Prompts
Shell
Prompt
C shell
machine-name%
C shell superuser
machine-name#
Typographic Conventions
Typeface*
Meaning
Examples
AaBbCc123
AaBbCc123
% su
Password:
AaBbCc123
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
URL
Documentation
http://www.sun.com/documentation/
Support
http://www.sun.com/support/
Training
http://www.sun.com/training/
Preface
xi
xii
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
1.1
Introduction
The CMM ILOM manages the Sun Blade 6000 modular system chassis. It provides
management of chassis components, and a method of accessing the service
processors in individual server modules. It also provides automatic control of the
chassis fan speed.
The Sun Blade 6000 modular system chassis holds up to ten server modules. Each of
these has its own service processor (SP). It is separate from the CMM ILOM, which
manages only the chassis.
Users interact with the CMM ILOM through the command-line interface (CLI).
Note All access to the CMM ILOM is through the CLI. WebGUI access is not
supported.
The CMM ILOM enables you to:
1-1
1.1.1
Status
Address Space
The CMM ILOM address space is divided into two regions:
1-2
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
1.1.1.1
Commands:
cd
load
reset
show
version
->
Chapter 1
1-3
cli Displays information about the CMM ILOM, including commands and version.
For example, you can look up the syntax of the command stop:
-> cd /CMM/cli/commands
-> show stop
/CMM/cli/commands/stop
Targets:
Properties:
requiredrole = administrator, operator
Commands:
cd
show
->
NTP See Section 5.2, Setting the CMM ILOM Clock on page 5-3.
syslog (sending syslog files to remote IP) See Section 6.4.1, Sending Logs to
Other Machines on page 6-6.
clock Set the clock. See Section 5.2, Setting the CMM ILOM Clock on page 5-3.
logs Show and clear the system logs. See Section 6.4, Viewing and Clearing Event
Logs on page 6-4.
network Used to set up the CMM ILOMs network configuration. See Chapter 2.
serial Displays the serial port configuration.
services Used to configure SNMP and to view SSH settings.
View SSH settings See Section 5.5, Viewing SSH Settings on page 5-6
1-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
1.1.1.2
CH Address Space
The /CH address space is used for managing the objects in the chassis. A typical
/CH address space contains the following objects:
Note Modules that are not present do not appear in this list. For example, a
chassis with no server module in slot 5 does not show BL5.
-> cd /CH
-> show
/CH
Targets:
CMM
BL0
BL1
BL2
BL3
BL4
BL5
BL6
BL7
BL8
BL9
T_AMB0
T_AMB1
T_OVRD
NORMAL
SERVICE
LOCATE
TEMPFAIL
FM0
FM1
FM2
FM3
FM4
FM5
PS0
PS1
NEM0
NEM1
Properties:
type = Chassis
board_part_number = 501-7376-03
board_serial_number = 1762TH1-0701YB006C
board_product_name = ASY,BD,MIDPLANE,C10
power_state = On
Commands:
cd
set
show
start
stop
Chapter 1
1-5
1.1.2
Components
The CMM ILOM provides access to the following components:
Chassis
Power supplies
Fan trays
NEMs
For each of these FRUs, the CMM ILOM enables you to detect whether it is present,
view its status, and view SEEPROM data.
The following sections describe how to use the CLI to access these components.
1.2
1.2.1
1-6
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Note The CMM ILOM logs in to the server module using the user name in the
user target under /CH/BLn/SP/cli (where n is the server module number). The
default is root.
To change the user name, see Section 1.2.2, Changing the Server Module User
Name on page 1-8.
4. Enter the SP password.
The server module SPs CLI interface appears. See the documentation for your
server module SP for instructions.
5. When you are done, type the command to exit the service processor. For
example, type:
exit.
The server module SP exits and the CMM ILOM CLI appears.
The following display shows an example:
-> cd /CH/BL2/SP/cli
/CH/BL2/SP/cli
-> start
Are you sure you want to start /CH/BL2/SP/cli (y/n)? y
Password:
Type the password to the server module SP.
Sun(TM) Integrated Lights Out Manager
Version 1.1.1
Copyright 2006 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.
Warning: password is set to factory default.
-> cd /SYS
/SYS
-> exit
Type this command to exit the server module SP and return to the
CMM ILOM.
Connection to 10.6.153.33 closed.
Chapter 1
1-7
1.2.2
1.2.3
1-8
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Chapter 1
1-9
1-10
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
2.1
Section 2.2.3, Configuring the CMM ILOM IP Address Using the CLI on
page 2-7
Using the Ethernet, as described in Section 2.1.2, Connecting to the CMM ILOM
Using an Ethernet Connection on page 2-4
2-1
2.1.1
2-2
9600 baud
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
3. Connect a serial cable from the serial port (SER MGT) on the chassis panel to
a terminal device.
The port appears in FIGURE 2-1.
Note The serial port requires that the serial cable connected to it use the following
pin assignments.
TABLE 2-1
Pin
Signal Description
Ground
Ground
Note If you connect a terminal or emulator to the serial port before the CMM
ILOM has been powered on or during its power on sequence, you will see bootup
messages.
When the system has booted, the CMM ILOM displays its login prompt:
SUNCMMnnnnnnnnnn login:
The first string in the prompt is the default host name. It consists of the prefix
SUNCMM and the CMM ILOMs MAC address. The MAC address for each
ILOM is unique.
Chapter 2
2-3
2.1.2
Know its IP address. See Section 2.2, Configuring the CMM ILOM IP Address
on page 2-5 for more information.
Have an Ethernet connection to the NET MGT 0 port, as shown in FIGURE 2-1.
Have an SSH client on the host you are using to connect to the CMM ILOM.
Note The default user name is root, and the default password is changeme. To
change it see Chapter 4.
2-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
For example:
$ ssh root@192.168.25.25
root@192.168.25.25's password:
Sun Integrated Lights Out Manager
Version 1.0
Copyright 2006 Sun Microsystems, Inc. All rights reserved.
Warning: password is set to factory default.
->
2.2
2.2.1
2.2.2
A DHCP server must be connected to the same subnet as the CMM ILOM. It must
be connected to the NET MGT 0 port.
The DHCP server must be configured to accept new media access control (MAC)
addresses, or configured to know the MAC address of the CMM ILOM.
Chapter 2
2-5
The CMM ILOM must be configured to use DHCP. This is its default setting.
If the CMM ILOM is not configured to use DHCP, you can configure it using the
instructions in Section 2.2.3, Configuring the CMM ILOM IP Address Using the
CLI on page 2-7.
If these conditions are present, when the CMM ILOM is powered on or reset, DHCP
automatically assigns it an IP address.
Note Some DHCP servers allow you to specify the IP address that it will assign to
the CMM ILOM. In this case, the CMM ILOM still must be configured for a
dynamic IP address, even though DHCPs choice of addresses is static.
Start the CMM ILOM CLI and enter the command show /CMM/network. The
ILOM displays its MAC address.
2-6
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
2.2.3
Use the Ethernet, as described in Section 2.1.2, Connecting to the CMM ILOM
Using an Ethernet Connection on page 2-4.
Note To use the Ethernet, you must already know the CMM ILOMs IP address.
2. Type the following command to set the working directory:
cd /CMM/network
3. Type the following commands:
Note If you connected to the ILOM using the Ethernet (SSH), you are
disconnected automatically, because you logged in from a different IP address.
Chapter 2
2-7
2-8
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
3.1
3.1.1
CLI Namespace
The CLI architecture is based on a hierarchical namespace, which is a predefined tree
that contains every managed object in the system. This namespace defines the
targets for each command verb.
The CMM ILOM includes two namespaces: the /CMM namespace and the /CH
namespace.
The /CMM namespace manages the CMM ILOM. For example, you use this
space to manage users, clock settings, and other CMM ILOM issues.
The /CH namespace manages the chassis. For example, use this namespace to
access server modules, fans, and power supplies.
3-1
3.1.2
Privilege Levels
The CLI provides two privilege levels: administrator and operator. Administrators
have full access to CMM ILOM functionality and operators have read-only access to
CMM ILOM information.
Note The default user, root, has administrator privileges. To create a user account
with operator privileges, see Chapter 4.
3.1.3
3.1.3.1
Command Verbs
The CLI supports the following command verbs.
TABLE 3-1
3-2
Command
Description
cd
create
delete
exit
help
load
reset
set
show
start
stop
version
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
3.1.3.2
Command Options
The CLI supports the options listed in TABLE 3-2. Not all options are supported for all
commands. See a specific command section for the options that are valid with that
command. The help option can be used with any command.
TABLE 3-2
Command Options
3.1.3.3
Short Form
Description
-default
-destination
-display
-d
-force
-f
-help
-h
-level
-l
-output
-o
-script
-source
Command Targets
Every object in your namespace is a target. Not all targets are supported for all
commands. Section A.2, CLI Command Reference on page A-5 lists each
command, with its targets and properties.
3.1.3.4
Command Properties
Properties are the configurable attributes specific to each object. An object can have
one or more properties. Section A.2, CLI Command Reference on page A-5 lists
each command, with its targets and properties.
Chapter 3
3-3
3.2
Command Syntax
To execute most commands, you need to specify the location of the target, then enter
the command. You can execute commands individually, or you can combine them on
the same command line.
1. To execute commands individually:
a. Navigate to the namespace using the CD command.
For example:
cd /CMM/services/snmp
b. Enter the verb, target, and value.
For example:
set port=161
2. To combine commands, use the form verb path/target=value.
For example:
set /CMM/services/snmp port=160
The following display shows both methods:
-> cd /CMM/services/snmp
/CMM/services/snmp
-> set port=161
Set 'port' to '161'
value
- Navigate to namespace
3-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
4.1
Caution The CMM ILOM includes a user account called sunservice, which shares
the CMM ILOM root password. Normally, it is used exclusively by Sun Service
personnel; however, it can also be used to perform recovery procedures documented
in the product notes. Incorrect use of this account can corrupt the service processor
image or operations.
The roles include:
4-1
4.2
4.2.1
4.2.2
4.2.3
4-2
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
4.2.4
4.2.4.1
Syntax
set target [propertyname=value]
4.2.4.2
Target
Property
Value
Default
/CMM/users/username
permissions
password
administrator|operator
string
operator
Examples
When changing the role for user1 from administrator to operator type:
-> set /CMM/users/user1 role=operator
To change the password for user1, type:
-> set /CMM/users/user1 password
Changing password for user /CMM/users/user1/password...
Enter new password:********
Enter new password again:********
New password was successfully set for user /CMM/users/user1
Chapter 4
4-3
4-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
5.1
5.1.1
5-1
5.1.2
Note Ensure that the same IP address is always assigned to the CMM ILOM by
either assigning a static IP address after initial setup, or configuring your DHCP
server to always assign the same IP address. This enables the CMM ILOM to be
easily located on the network.
5.1.2.1
Syntax
set target [propertyname=value]
5.1.2.2
5-2
Target
Property
Value
/CMM/network
ipaddress
ipdiscovery
ipgateway
ipnetmask
macaddress
MAC address of
CMM ILOM
commitpending
pendingipaddress
pendingipdiscovery
pendingipgateway
pendingipnetmask
true|(none)
ipaddress|none
dhcp|static
ipaddress|none
ipdotteddecimal
Default
(none)
none
dhcp
none
255.255.255.255
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Examples
To change the IP address for the CMM ILOM, type:
-> set /CMM/network pendingipaddress=nnn.nn.nn.nn commitpending=
true
Note Changing the IP address disconnects your active session if you are
connected to the CMM ILOM via a network.
To change the network settings from DHCP to static assigned settings, type:
-> set /CMM/network pendingipdiscovery=static pendingipaddress=
nnn.nn.nn.nn pendingipgateway=nnn.nn.nn.nn pendingipnetmask=
nnn.nn.nn.nn commitpending=true
5.2
5.2.1
5.2.2
Chapter 5
5-3
5.2.2.1
Syntax
set target [propertyname=value]
5.2.2.2
Target
Property
Value
Default
/CMM/clients/ntp/server/1
address
ipaddress
(none)
/CMM/clients/ntp/server/2
address
ipaddress
(none)
Example
To configure your clock to synchronize with an NTP server, type:
-> set /CMM/clients/ntp/server/1 address=125.128.84.20
Then enable the NTP service by typing:
-> set /CMM/clock/usentpserver=enabled
Note After you enable the NTP service, it can take up to five minutes for the clock
to synchronize.
5-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
5.2.3
5.3
5.4
Caution Ensure that you have reliable power before upgrading your firmware. If
power to the system fails (for example, if the wall socket power fails or the system is
unplugged) during the firmware update procedure, the CMM ILOM could be left in
an unbootable state.
Chapter 5
5-5
Note The upgrade takes about five minutes. During this time, no other tasks can
be performed in the CMM ILOM.
A successful firmware causes the CMM ILOM to reboot.
A firmware upgrade causes the server and the CMM ILOM to be reset. It is
recommended that a clean shutdown of the server be done prior to the upgrade
procedure.
An upgrade takes about 6 minutes to complete. The CMM ILOM enters a special
mode to load new firmware. No other tasks can be performed in the CMM ILOM
until the firmware upgrade is complete and the CMM ILOM is reset.
1. If the server OS is running, perform a clean shutdown.
2. Type the following command to update the CMM ILOM firmware:
load -source URL
Note A network failure during the file upload will result in a time-out. This
causes the CMM ILOM to reboot with the prior version of the CMM ILOM firmware.
Example:
-> load -source tftp://zbank/ah27901/CMM-P0-rom.pkg
Are you sure you want to load the specified file (y/n)? y
File upload is complete.
Firmware image verification is complete.
Do you want to preserve the configuration (y/n)? n
Updating firmware in flash RAM:
.
Firmware update is complete.
ILOM will not be restarted with the new firmware.
5.5
5-6
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 5-3 shows the valid targets and properties for SSH values.
TABLE 5-3
Target
Property
/CMM/services/ssh/keys/dsa
fingerprint
length
publickey
/CMM/services/ssh/keys/rsa
fingerprint
length
publickey
Chapter 5
5-7
Example:
-> show /CMM/services/ssh/keys/dsa
/CMM/services/ssh/keys/dsa
Targets:
Properties:
fingerprint =
f7:49:85:b0:e3:65:c0:d0:96:48:06:f5:8c:b7:9c:6b
length = 1024
publickey =
AAAAB3NzaC1kc3MAAACBAKh+LPnkehPiIou96JraqiZ7qjJ4KTc4DdNJ3ZkBZ94X
Krz2B5BNROCL7h4Gb7uAaMZEgtpPqefKy5awEvkA8jNyL5P=
Commands:
cd
show
->
5.6
5.6.1
5-8
Command
Information Displayed
version
show /CMM/cli/commands
show /CMM/sessions
help targets
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Type the following command to display the current CMM ILOM version:
version
For example:
-> version
CMM firmware 1.1.6
CMM firmware build number: 16671
CMM firmware date: Tue Feb 27 11:01:21 PST 2007
CMM filesystem version: 0.1.14
->
5.7
Chapter 5
5-9
5-10
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
6.1
6-1
Note The displays in this section are examples. For detailed sensor information,
see Chapter 10.
-> cd /CH
-> show
/CH
Targets:
CMM
BL0
BL1
BL2
BL3
BL4
BL5
BL6
BL7
BL8
BL9
T_AMB0
T_AMB1
T_OVRD
NORMAL
SERVICE
LOCATE
TEMPFAIL
FM0
FM1
FM2
FM3
FM4
FM5
PS0
PS1
NEM0
NEM1
Properties:
type = Chassis
board_part_number = 501-7376-03
board_serial_number = 1762TH1-0701YB006C
board_product_name = ASY,BD,MIDPLANE,C10
power_state = On
Commands:
cd
set
show
start
stop
->
6-2
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Chapter 6
6-3
6.2
Caution Do not use this command unless all the server modules in the chassis are
shut down. Shutting down the chassis when server modules are not shut down can
damage chassis components and the server modules.
6.3
6.4
Caution The CMM ILOM tags all events or actions with LocalTime=GMT (or
UDT). Browser clients show these events in LocalTime. This can cause apparent
discrepancies in the event log. When an event occurs on the CMM ILOM, the event
log shows it in UDT, but a client would show it in local time.
6-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
1. Navigate to /CMM/logs/event.
2. From the CLI, type show list
The event log scrolls onto your screen.
-> cd /CMM/logs/event
/CMM/logs/event
-> show list
/CMM/logs/event/list
Targets:
Properties:
Commands:
show
ID
----1522
Date/Time
Class
Type
Severity
------------------------ -------- -------- -------Sun Jul 30 01:11:36 2006 Audit
Log
minor
root : Close Session : object = /session/type : value = www : success
1521
Sun Jul 30 01:05:34 2006 Audit
Log
minor
root : Close Session : session ID = 1307912184 : success
1520
Sun Jul 30 01:05:33 2006 Audit
Log
minor
root : Close Session : session ID = 2004820934 : success
Paused: press any key to continue, or 'q' to quit
Chapter 6
6-5
6.4.1
6.5
6-6
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
7.1
7.2
7-2
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
For example, to update an entry in the directory, an LDAP client submits the
distinguished name of the entry with updated attribute information to the LDAP
server. The LDAP server uses the distinguished name to find the entry and performs
a modify operation to update the entry in the directory. The updated information is
immediately available to all the distributed applications using that LDAP server.
To perform any of these LDAP operations, an LDAP client needs to establish a
connection with an LDAP server. LDAP specifies the use of TCP/IP port number
389, although servers may run on other ports.
Your Sun server can be a client of an LDAP server. To use LDAP authentication, you
need to create a user on your LDAP server that your Sun server can authenticate, or
bind to, so that the client has permission to search the proper directory on the LDAP
server.
7.3
Note This task is similar to configuring LDAP as a name service for Linux or the
Solaris operating system.
Chapter 7
7-3
7.3.1
Required Property
Description
uid
uidNumber
gidNumber
userPassword
Password
homeDirectory
loginShell
3. Provide the CMM ILOM access to user accounts on your LDAP server.
Either enable your LDAP server to accept anonymous binds, or create a proxy
user on your LDAP server that has read-only access to all user accounts that will
authenticate through the CMM ILOM.
See your LDAP server documentation for more details.
7.3.2
7-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
2. Enter the IP address of the LDAP server. From the command line, type:
set /CMM/clients/ldap ipaddress=ldapipaddress
3. Assign the port used to communicate with the LDAP server; the default port is
389. From the command line, type:
set /CMM/clients/ldap port=ldapport
Enter the distinguished name of the branch of your LDAP tree that contains
users and groups. From the command line, type:
set /CMM/clients/ldap searchbase="ou=people, ou=sales, dc=sun, dc=com"
This is the location in your LDAP tree that you want to search for user
authentication.
4. Set the state of the LDAP service to enabled. From the command line, type:
set /CMM/clients/ldap state=enabled
5. To verify that LDAP authentication works, log in to the CMM ILOM using an
LDAP user name and password.
Note The CMM ILOM searches local users before it searches LDAP users. If an
LDAP user name exists as a local user, the CMM ILOM uses the local account for
authentication.
Chapter 7
7-5
7-6
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
RADIUS
The CMM ILOM supports Remote Authentication Dial-In User Service (RADIUS)
authentication for users, based on RFC 2058 and RFC 2059. RADIUS is an
authentication protocol that facilitates centralized user administration. RADIUS
allows many servers shared access to user data in a central database, providing
better security and easier administration.
This chapter contains the following sections:
8.1
RADIUS Overview
RADIUS is based on a client-server model. The RADIUS server provides the user
authentication data and can grant or deny access, and the clients send user data to
the server and receive an accept or deny response. A RADIUS server can work in
conjunction with multiple RADIUS servers and other types of authentication
servers.
In the RADIUS client-server model, the client sends an Access-Request query to the
RADIUS server. When the server receives an Access-Request message from a client,
it searches the database for that users authentication information. If the users
information is not found, the server sends an Access-Reject message and the user is
denied access to the requested service. If the users information is found, the server
responds with an Access-Accept message. The Access-Accept message confirms the
users authentication data and grants the user access to the requested service.
8-1
All transactions between the RADIUS client and server are authenticated by the use
of a shared secret. The client and server must each know the secret because it is
never passed over the network. You must know the shared secret to configure
RADIUS authenticating for the CMM ILOM.
To use RADIUS configuration with the CMM ILOM, you must configure the CMM
ILOM as a RADIUS client. For more information, see Section 8.2, Configuring
RADIUS Settings on page 8-2.
8.2
8.2.1
RADIUS Parameters
TABLE 8-1 describes the RADIUS parameters.
TABLE 8-1
8-2
CLI
Description
defaultrole
administrator|operator
ipaddress ipaddress
port portnum
state enabled|disabled
secret text
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
8.3
RADIUS Commands
This section describes the RADIUS commands.
8.3.1
show /CMM/clients/radius
This command is available to administrators and operators.
Purpose
Use this command to view the properties associated with RADIUS authentication.
Syntax
show /CMM/clients/radius
Properties
defaultrole This is the role assigned to all RADIUS users. It is either administrator
or operator.
ipaddress The IP address of your RADIUS server.
port The port number used to communicate with your RADIUS server. The default
port is 1812.
secret Enter the shared secret used to gain access to your RADIUS server.
state Choose enabled or disabled to allow or deny access to your RADIUS
users.
Chapter 8
RADIUS
8-3
Example
-> show /CMM/clients/radius
/CMM/clients/radius
Targets:
Properties:
defaultrole = Operator
ipaddress = 129.144.36.142
port = 1812
secret = (none)
state = enabled
Commands:
cd
set
show
->
8.3.2
set /CMM/clients/radius
This command is available to administrators.
Purpose
Use this command to configure the properties associated with RADIUS
authentication on a service processor.
Syntax
set /CMM/clients/radius [defaultrole=[Administrator|Operator]
ipaddress=radiusserverIP port=port# secret=radiussecret state=
[enabled|disabled]]
Properties
8-4
defaultrole Assign a permission level that will apply to all RADIUS users.
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
port The port number used to communicate with your RADIUS server. The
default port is 1812.
secret Enter the shared secret used to gain access to your RADIUS server. This is
also known as an encryption key.
state Choose enabled or disabled to allow or deny access to your RADIUS users.
Example
-> set /CMM/clients/radius state=enabled ipaddress=10.8.145.77
Set 'state' to 'enabled'
Set 'ipaddress' to '10.8.145.77
8.3.3
show /CMM/clients
This command is available to administrators and operators.
Purpose
Use this command to view clients that can recive data from a service processor,
including LDAP, NTP, RADIUS, and SYSLOG clients.
Syntax
show /CMM/clients
Chapter 8
RADIUS
8-5
Example
-> show /CMM/clients
/CMM/clients
Targets:
ldap
ntp
radius
syslog
Properties:
Commands:
cd
show
Note Users with operator privileges can only view the ntp and syslog targets.
The radius and ldap targets remain hidden.
8-6
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
9.1
Section 9.2, SNMP Management Information Base (MIB) Files on page 9-2
Section 9.5, About the CMM ILOM and SNMP on page 9-4
About SNMP
The Sun server supports the Simple Network Management Protocol (SNMP)
interface, versions 1, 2c, and 3. SNMP is an open technology that enables the
management of networks and devices, or nodes, connected to the network. SNMP
messages are sent over IP using the User Datagram Protocol (UDP). Any
management application that supports SNMP can manage your server.
9.1.1
9-1
Managed nodes are any number of devices, including servers, routers, and hubs that
host SNMP management agents responsible for carrying out the requests from
management stations. The management station monitors nodes by polling
management agents for the appropriate information using queries. Managed nodes
can also provide unsolicited status information to a management station in the form
of a trap. SNMP is the protocol used to communicate management information
between the management stations and agents.
The SNMP agent is preinstalled and runs on the CMM ILOM, so all SNMP
management of the server should occur through the CMM ILOM. To utilize this
feature, your operating system must have an SNMP client application. See your
operating system vendor for more information.
The SNMP agent on your CMM ILOM provides the following capabilities: inventory
management and sensor and system state monitoring.
9.2
9-2
SNMP-FRAMEWORK-MIB
SNMP-USER-BASED-MIB
SNMP-MPD-MIB SUN-PLATFORM-MIB
ENTITY-MIB
SUN-PLATFORM-MIB
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
9.3
MIBs Integration
Use the MIBs to integrate the management and monitoring of the server into SNMP
management consoles. The MIB branch is a private enterprise MIB, located at MIB
object iso(1)/org (3)/dod (6)/internet (1)/private (4)/enterprises (1)/sun
(42)/products (2). FIGURE 9-1 shows the arrangement. The standard SNMP port (port
161) is used by the SNMP agent on the CMM ILOM.
FIGURE 9-1
9.4
Chapter 9
9-3
Get
GetNext
GetResponse
Set
Trap
By default, port 161 is used for SNMP messages and port 162 is used to listen for
SNMP traps.
9.5
9.5.1
9.5.2
9-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
9.6
9.6.1
9.6.2
9.6.3
9.6.3.1
Syntax
set target [propertyname=value]
Chapter 9
9-5
9.6.3.2
TABLE 9-1
Target
Property
Value
Default
/CMM/services/snmp/
communities/communityname
permissions
ro|rw
ro
/CMM/services/snmp/users
/username
authenticationprotocol
authenticationpassword
permissions
privacyprotocol
privacypassword
MD5|SHA
string
ro|rw
none|DES
string
MD5
(null string)
ro
none*
(null string)
/CMM/services/snmp
engineid = none
port = 161
sets = enabled
v1 = disabled
v2c = disabled
v3 = disabled
string
integer
enabled|disabled
enabled|disabled
enabled|disabled
enabled|disabled
(null string)
161
disabled
disabled
disabled
enabled
* If the privacyprotocol property has a value other than none, then a privacypassword must be set.
9.6.3.3
Examples
When changing the parameters of SNMP users, you must set values for all the
properties, even if you are not changing all the values. For example, to change user
jeff's privacyprotocol to DES you must type:
-> set /CMM/services/snmp/users/jeff privacyprotocol=DES
privacypassword=password authenticationprotocol=SHA
authenticationpassword=password
Your changes would be invalid if you typed:
-> set /CMM/services/snmp/users/jeff privacyprotocol=DES
Note You can change SNMP user permissions without resetting the privacy and
authentication properties.
9-6
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
CHAPTER
10
Sensors
This chapter provides information about the CMM sensors.
Types of Sensors
Discrete Sensors
Discrete sensors display a single value from a set of possible values. The possible
values for discrete sensors are listed in TABLE 1.
Discrete sensors are displayed in the following format
/PATH/TO/SENSOR
Targets:
$(POSSIBLE_SUB_SENSORS)
Properties:
type = $(SENSOR_TYPE)
class = Discrete
value = $(SENSOR_VALUE)
10-1
Threshold Sensors
Threshold sensors display analog reading, such as temperature or voltage levels, and
associated thresholds for that reading. These can be configured to generate system
events when they exceed specified thresholds.
In general, these sensors are displayed in the following format:
/PATH/TO/SENSOR
Targets:
$(POSSIBLE_SUB_SENSORS)
Properties:
type = $(SENSOR_TYPE)
class = Threshold
value = $(SENSOR_VALUE) $(SENSOR_UNITS)
upper_nonrecov_threshold = $(UNR_THRESH) $(SENSOR_UNITS)
upper_critical_threshold = $(UC_THRESH) $(SENSOR_UNITS)
upper_noncritical_threshold = $(UNC_THRESH) $(SENSOR_UNITS)
lower_nonrecov_threshold = $(LNR_THRESH) $(SENSOR_UNITS)
lower_critical_threshold = $(LC_THRESH) $(SENSOR_UNITS)
lower_noncritical_threshold = $(LNC_THRESH) $(SENSOR_UNITS)
If the CLI has no access to threshold values, for example if a component is not
present, the corresponding sensor is displayed as 0.000.
Displaying Sensors
All sensors are located in the /CH namespace. The fields are separated by periods
and (in limited cases) by the underbar character _. The first field of the sensor ID
is one of the targets in /CH.
To display the sensors using the CLI, separate the fields into targets and navigate
using the cd and show commands:
For example:
10-2
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
fm3.f0.speed (0xb)
can be viewed by entering:
Sensor Information
The following table shows the CMM sensors:
TABLE 1
Name
Sensor ID
CMM Sensors
Data
nem0.prsnt (0x1)
Entity ID
44.0
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
nem1.prsnt (0x2)
Entity ID
44.1
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
ps0.prsnt (0x3)
Entity ID
10.0
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Path to Sensor
Description
/CH/NEM0
NEM 0 presence
/CH/NEM1
NEM 1 presence
/CH/PS0
Chapter 10
Sensors
10-3
TABLE 1
Name
Data
Sensor ID
ps1.prsnt (0x4)
Entity ID
10.1
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
fm0.f0.speed (0x5)
Entity ID
29.0
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
Description
/CH/PS1
/CH/FM0/F0/SPEED
/CH/FM0/F1/SPEED
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
Path to Sensor
na
Assertions Enabled
Sensor ID
fm0.f1.speed (0x6)
Entity ID
29.0
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
10-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
Upper Critical
Upper NonRecoverable
Data
Path to Sensor
Description
/CH/FM1/F0/SPEED
/CH/FM1/F1/SPEED
na
na
Assertions Enabled
Sensor ID
fm1.f0.speed (0x7)
Entity ID
29.1
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
na
Assertions Enabled
Sensor ID
fm1.f1.speed (0x8)
Entity ID
29.1
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Chapter 10
Sensors
10-5
TABLE 1
Name
Data
Upper NonRecoverable
Path to Sensor
Description
/CH/FM2/F0/SPEED
/CH/FM2/F1/SPEED
na
Assertions Enabled
Sensor ID
fm2.f0.speed (0x9)
Entity ID
29.2
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
na
Assertions Enabled
Sensor ID
fm2.f1.speed (0xa)
Entity ID
29.2
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
10-6
na
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
Data
Path to Sensor
Description
/CH/FM3/F0/SPEED
/CH/FM3/F1/SPEED
Assertions Enabled
Sensor ID
fm3.f0.speed (0xb)
Entity ID
29.3
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
na
Assertions Enabled
Sensor ID
fm3.f1.speed (0xc)
Entity ID
29.3
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
na
Assertions Enabled
Chapter 10
Sensors
10-7
TABLE 1
Name
Data
Sensor ID
fm4.f0.speed (0xd)
Entity ID
29.4
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
Description
/CH/FM4/F0/SPEED
/CH/FM4/F1/SPEED
/CH/FM5/F0/SPEED
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
Path to Sensor
na
Assertions Enabled
Sensor ID
fm4.f1.speed (0xe)
Entity ID
29.4
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
na
Assertions Enabled
Sensor ID
Entity ID
10-8
fm5.f0.speed (0xf)
29.5
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
Data
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
Description
/CH/FM5/F1/SPEED
/CH/FM0/FAIL
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
Path to Sensor
na
Assertions Enabled
Sensor ID
fm5.f1.speed (0x10)
Entity ID
29.5
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
na
Assertions Enabled
Sensor ID
fm0.fail (0x11)
Entity ID
29.0
Fan
Chapter 10
Sensors
10-9
TABLE 1
Name
Data
States Asserted
Sensor ID
Path to Sensor
Description
/CH/FM1/FAIL
/CH/FM2/FAIL
/CH/FM3/FAIL
/CH/FM4/FAIL
Digital State
[Predictive Failure
Asserted|Deasserted]
fm1.fail (0x12)
Entity ID
29.1
Fan
States Asserted
Digital State
[Predictive Failure
Deasserted]
Sensor ID
fm2.fail (0x13)
Entity ID
29.2
Fan
States Asserted
Sensor ID
Digital State
[Predictive Failure
Asserted|Deasserted]
fm3.fail (0x14)
Entity ID
29.3
Fan
States Asserted
Sensor ID
Digital State
[Predictive Failure
Asserted|Deasserted]
fm4.fail (0x15)
Entity ID
29.4
Fan
States Asserted
Digital State
[Predictive Failure
Deasserted]
10-10
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
Sensor ID
Data
fm5.fail (0x16)
Entity ID
29.5
Fan
States Asserted
Sensor ID
ps0.status (0x17)
10.0
Power Supply
Sensor ID
ps1.status (0x18)
10.1
Power Supply
ps0.pstate_0 (0x19)
Entity ID
10.0
Voltage
States Asserted
Sensor ID
/CH/PS0/STATUS
/CH/PS1/STATUS
CH/PS0/S0/PSTATE
CH/PS0/S1/PSTATE
Digital State
[Predictive Failure
Asserted|Deasserted]
ps0.pstate_1 (0x1a)
Entity ID
10.0
Voltage
States Asserted
/CH/FM5/FAIL
Power Supply
[AC out-of-range, but
present]
Entity ID
Sensor ID
Description
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
Path to Sensor
Digital State
[Predictive Failure
Asserted|Deasserted]
Chapter 10
Sensors
10-11
TABLE 1
Name
Data
Sensor ID
ps0.t_amb (0x1b)
Entity ID
10.0
Temperature
Sensor Reading
23 (+/- 0) degrees C
Status
ok
Lower NonRecoverable
Description
/CH/PS0/T_AMB
/CH/PS0/FAN
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
Path to Sensor
na
Assertions Enabled
Sensor ID
ps0.fan_speed (0x1c)
Entity ID
10.0
Fan
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
na
Assertions Enabled
10-12
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
Sensor ID
Data
ps0.V12V (0x1f)
Entity ID
10.0
Voltage
Sensor Reading
Status
ok
Lower NonRecoverable
Description
/CH/PS0/V+12V
/CH/PS0/V+3_3V
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
Path to Sensor
na
Assertions Enabled
Sensor ID
ps0.V3_3V (0x20)
Entity ID
10.0
Voltage
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
na
Assertions Enabled
Chapter 10
Sensors
10-13
TABLE 1
Name
Data
Sensor ID
ps0.I12V_0 (0x21)
Entity ID
10.0
Current
Sensor Reading
Status
ok
Lower NonRecoverable
Description
/CH/PS0/S0/I+12V
/CH/PS0/S1/I+12V
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
Path to Sensor
na
Assertions Enabled
Sensor ID
ps0.I12V_1 (0x22)
Entity ID
10.0
Current
Sensor Reading
Status
ok
Lower NonRecoverable
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
na
Assertions Enabled
10-14
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
Sensor ID
Data
ps0.I3_3V (0x23)
Entity ID
10.0
Current
Sensor Reading
Status
ok
Lower NonRecoverable
Description
/CH/PS0/I+3_3V
/CH/PS0/S0/ACFAIL
/CH/PS0/S1/ACFAIL
/CH/PS0/FAN_FAIL
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
Path to Sensor
na
Assertions Enabled
Sensor ID
ps0.ac0_fail (0x24)
Entity ID
10.0
Voltage
States Asserted
Sensor ID
Digital State
[Predictive Failure
Asserted|Deasserted]
ps0.ac1_fail (0x25)
Entity ID
10.0
Voltage
States Asserted
Sensor ID
Digital State
[Predictive Failure
Asserted|Deasserted]
ps0.fan_fail (0x26)
Chapter 10
Sensors
10-15
TABLE 1
Name
Data
Entity ID
10.0
Fan
States Asserted
Sensor ID
ps0.v12v_0_fault (0x27)
10.0
Voltage
Sensor ID
ps0.v12v_1_fault (0x28)
10.0
Voltage
Sensor ID
ps0.V3_3V_fault (0x29)
10.0
Voltage
Sensor ID
/CH/PS0/S1/V+12V_FAULT
/CH/PS0/V+3_3V_FAULT
/CH/PS0/T_AMB_FAULT
Digital State
[Predictive Failure
Asserted|Deasserted]
ps0.t_amb_fault (0x2a)
Entity ID
10.0
Temperature
10-16
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
/CH/PS0/S0/V+12V_FAULT
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
Description
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
Path to Sensor
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
States Asserted
Sensor ID
Data
ps0.I12V_0_fault (0x2b)
10.0
Current
Sensor ID
ps0.I12V_1_fault (0x2c)
10.0
Current
Sensor ID
ps0.I12V_0_warn (0x2d)
10.0
Current
Sensor ID
/CH/PS0/S1/I+12V_FAULT
/CH/PS0/S0/V+12V_WARN
/CH/PS0/S1/V+12V_WARN
Digital State
[Predictive Failure
Asserted|Deasserted]
ps0.I12V_1_warn (0x2e)
Entity ID
10.0
Current
States Asserted
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
/CH/PS0/S0/I+12V_FAULT
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
Description
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
Path to Sensor
Digital State
[Predictive Failure
Asserted|Deasserted]
Chapter 10
Sensors
10-17
TABLE 1
Name
Data
Sensor ID
ps0.t_amb_warn (0x2f)
Entity ID
10.0
Temperature
States Asserted
Digital State
[Predictive Failure
Deasserted]
Sensor ID
ps1.pstate_0 (0x30)
10.1
Voltage
States Asserted
Digital State
Sensor ID
ps1.pstate_1 (0x31)
10.1
Voltage
States Asserted
Digital State
Sensor ID
ps1.t_amb (0x32)
10.1
Temperature
10-18
/CH/PS1/S0/PSTATE
/CH/PS1/S1/PSTATE
CH/PS1/T_AMB
Digital State
[State
Asserted|Deasserted]
Entity ID
Sensor Reading
/CH/PS0/T_AMB_WARN
Digital State
[State
Asserted|Deasserted]
Entity ID
[Predictive Failure
Deasserted]
Description
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
[Predictive Failure
Deasserted]
Path to Sensor
19 degrees C
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
Data
Path to Sensor
Description
/CH/PS1/FAN
CH/PS1/V+12V
/CH/PS1/V+3_3V
CH/PS1/S0/I+12V
Assertions Enabled
Sensor ID
ps1.fan_speed (0x33)
Entity ID
10.1
Fan
Sensor Reading
11985 RPM
Assertions Enabled
Sensor ID
ps1.V12V (0x36)
Entity ID
10.1
Voltage
Sensor Reading
12.24 Volts
Assertions Enabled
Sensor ID
ps1.V3_3V (0x37)
Entity ID
10.1
Voltage
Sensor Reading
3.32 Volts
Assertions Enabled
Sensor ID
ps1.I12V_0 (0x38)
Entity ID
10.1
Current
Sensor Reading
43.75 Amps
Assertions Enabled
Chapter 10
Sensors
10-19
TABLE 1
Name
Data
Sensor ID
ps1.I12V_1 (0x39)
Entity ID
10.1
Current
Sensor Reading
45 Amps
Path to Sensor
Description
/CH/PS1/S1/I+12V
/CH/PS1/I+3_3V
/CH/PS1/S0ACFAIL
/CH/PS1/S1/ACFAIL
/CH/PS1/FAN_FAIL
Assertions Enabled
Sensor ID
ps1.I3_3V (0x3a)
Entity ID
10.1
Current
Sensor Reading
.0.30 Amps
Assertions Enabled
Sensor ID
ps1.ac0_fail (0x3b)
Entity ID
10.1
Voltage
States Asserted
Sensor ID
Digital State
[Predictive Failure
Asserted|Deasserted]
ps1.ac1_fail (0x3c)
Entity ID
10.1
Voltage
States Asserted
Sensor ID
Digital State
[Predictive Failure
Asserted|Deasserted]
ps1.fan_fail (0x3d)
Entity ID
10.1
Fan
10-20
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
States Asserted
Sensor ID
Data
ps1.v12v_0_fault (0x3e)
10.1
Voltage
Sensor ID
ps1.v12v_2_fault (0x3f)
10.1
Voltage
Sensor ID
ps1.V3_3V_fault (0x40)
10.1
Voltage
Sensor ID
/CH/PS1/S1/V+12V_FAULT
/CH/PS1/V+3_3V_FAULT
/CH/PS1/T_AMB_FAULT
Digital State
[Predictive Failure
Asserted|Deasserted]
ps1.t_amb_fault (0x41)
Entity ID
10.1
Temperature
States Asserted
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
/CH/PS1/S0/V+12V_FAULT
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
Description
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
Path to Sensor
Digital State
[Predictive Failure
Asserted|Deasserted]
Chapter 10
Sensors
10-21
TABLE 1
Name
Data
Sensor ID
ps1.I12V_0_fault (0x42)
Entity ID
10.1
Current
States Asserted
Sensor ID
ps1.I12V_1_fault (0x43)
10.1
Current
Sensor ID
ps1.I12V_0_warn (0x44)
10.1
Current
Sensor ID
ps1.I12V_1_warn (0x45)
10.1
Current
10-22
/CH/PS1/S1/I+12V_FAULT
/CH/PS1/S0/V+12V_WARN
/CH/PS1/S1/V+12V_WARN
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
/CH/PS1/S0/I+12V_FAULT
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
Description
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
States Asserted
Path to Sensor
Digital State
[Predictive Failure
Asserted|Deasserted]
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
Sensor ID
Data
ps1.t_amb_warn (0x46)
Entity ID
10.1
Temperature
States Asserted
Sensor ID
ch.t_amb_0 (0x6e)
23.0
Temperature
Sensor Reading
23 (+/- 0) degrees C
Status
ok
/CH/PS1/T_AMB_WARN
/CH/T_AMD0
Chassis ambient
temperature sensor 0
reading
/CH/T_AMD1
Chassis ambient
temperature sensor
2reading
na
Lower Critical
na
Lower Non-Critical
na
Upper Non-Critical
na
Upper Critical
na
Upper NonRecoverable
Description
Digital State
[Predictive Failure
Asserted|Deasserted]
Entity ID
Lower NonRecoverable
Path to Sensor
na
Assertions Enabled
Sensor ID
ch.t_amb_1 (0x6f)
Entity ID
23.0
Temperature
Sensor Reading
Not Present
Assertions Enabled
Chapter 10
Sensors
10-23
TABLE 1
Name
Data
Sensor ID
bl0.prsnt (0x64)
Entity ID
7.0
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
bl1.prsnt (0x65)
Entity ID
7.1
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
bl2.prsnt (0x66)
Entity ID
7.2
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
bl3.prsnt (0x67)
Entity ID
7.3
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
bl4.prsnt (0x68)
Entity ID
7.4
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
Entity ID
10-24
bl5.prsnt (0x69)
Path to Sensor
Description
/CH/BL0
Blade 0 presence
/CH/BL1
Blade 1 presence
/CH/BL2
Blade 2 presence
/CH/BL3
Blade 3 presence
/CH/BL4
Blade 4 presence
/CH/BL5
Blade 5 presence
7.5
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE 1
Name
Data
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
bl6.prsnt (0x6a)
Entity ID
7.6
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
bl7.prsnt (0x6b)
Entity ID
7.7
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
bl8.prsnt (0x6c)
Entity ID
7.8
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Sensor ID
bl9.prsnt (0x6d)
Entity ID
7.9
Entity Presence
States Asserted
Availability State
[Device Present|Absent]
Path to Sensor
Description
/CH/BL8
Blade 8 presence
/CH/BL7
Blade 7 presence
/CH/BL8
Blade 8 presence
/CH/BL9
Blade 9 presence
Chapter 10
Sensors
10-25
10-26
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
APPENDIX
A.1
Content
Typeface
Description
Your input
Fixed-width
bold
Onscreen output
Fixed-width
regular
Variable
Italic
Square brackets [ ]
Vertical bars |
A-1
TABLE A-2
General Commands
Description
Command
help targets
exit
version
show /CH/clock
show /CH/cli/commands
show /CH/sessions
help create
show /CH/logs/event/list
TABLE A-3
User Commands
Description
Command
delete /CH/users/user1
A-2
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE A-4
Description
Command
Display network
configuration information.
show /CH/network
show /CH/serial/external
show /CH/serial/host
TABLE A-5
Description
Command
show /CH/services/ssh/keys/dsa
show /CH/services/ssh/keys/rsa
Appendix A
A-3
TABLE A-6
Description
Command
show /CH/services/snmp/users
create /CH/services/snmp/users/snmpusername
authenticationpassword=password
authenticationprotocol=MD5|SHA
permissions=rw|ro privacypassword=password
privacyprotocol=none|DES
delete /CH/services/snmp/users/snmpusername
show /CH/services/snmp/communities/public
create /CH/services/snmp/communities/
public/comm1
delete /CH/services/snmp/communities/
public/comm1
show /CH/services/snmp/communities/private
create /CH/services/snmp/communities/
private/comm2
delete /CH/services/snmp/communities/
private/comm2
TABLE A-7
A-4
SNMP Commands
Description
Command
start /CMM
stop /CMM
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE A-7
Description
Command
reset /CMM
TABLE A-8
A.2
stop /CH/console
Clock Settings
Description
Command
A.2.1
Syntax
cd target
Appendix A
A-5
Options
[-d|default] [-e|examine] [-h|help]
Examples
To create a user named sally, cd to /CH/users, then execute the create
command with /CH/users as the default target.
-> cd /CH/users
-> create sally
To find your location, type cd.
-> cd /CH/users
A.2.2
Syntax
create [options] target [propertyname=value]
Options
[-d|default] [-e|examine] [-h|help]
A-6
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Valid Targets
Properties
Values
Default
/CH/users/username
password
role
string
(none)
administrator operator
/operator
/CH/services/snmp/community/
communityname
permissions
ro|rw
ro
/CH/services/snmp/user/
username
authenticationprotocol
authenticationpassword
permissions
privacyprotocol
privacypassword
MD5
string
ro|rw
none|DES
string
MD5
(null string)
ro
DES
(null string)
Example
-> create /CH/users/susan role=administrator
A.2.3
Syntax
delete [options] [-script] target
Options
[-x|examine] [-f|force] [-h|help] [-script]
Appendix A
A-7
Targets
TABLE A-10
Valid Targets
/CH/users/username
/CH/services/snmp/community/communityname
/CH/services/snmp/user/username
Examples
-> delete /CH/users/susan
-> delete -script /CH/services/snmp/user/john
A.2.4
Syntax
exit [options]
Options
[-x|examine] [-h|help]
A.2.5
A-8
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Syntax
help [options] command [targets ]
Options
[-x|examine] [-h|help] [-output terse|verbose]
Commands
cd, create, delete, exit, help, load, reset, set, show, start,
stop, version
Examples
-> help load
The load command is used to transfer a file from a server to a target.
Usage: load -source URL [target]
-source : specify the location to get a file
-> help -output verbose reset
The reset command is used to reset a target.
Usage: reset [-script] [target]
Available options for this command:
-script : do not prompt for yes/no confirmation and act as if yes was specified.
Examples:
-> reset /CMM
Are you sure you want to reset /CMM (y/n)? y
Performing hard reset on /CMM
-> reset
Appendix A
A-9
A.2.6
Syntax
load -source URL
Options
[-x|examine] [-h|help] [-source]
Example
-> load -source tftp://archive/newmainimage
A-10
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Note A firmware upgrade will cause the server and ILOM to be reset. It is
recommended that a clean shutdown of the server be done prior to the upgrade
procedure. An upgrade takes about five minutes to complete. ILOM enters a special
mode to load new firmware. No other tasks can be performed in ILOM until the
firmware upgrade is complete and ILOM is reset.
A.2.7
Note The reset command does not affect the power state of hardware devices.
Syntax
reset [options] target
Options
[-x|examine] [-h|help] [-script]
Appendix A
A-11
Targets
TABLE A-11
Valid Targets
/CH
/CMM
Examples
-> reset /CH
-> reset /CMM
A.2.8
Syntax
set [options] [-default] target [propertyname=value]
Options
[-x examine] [-h help]
Valid Targets
Properties
Values
Default
/CH/users/username
password
role
string
administrator|operator
(none)
operator
/CH/clock
usentpserver
enabled|disabled
/CH/clock
/CH/services/http
servicestate
enabled|disabled
/CH/services/http
/CH/services/https
servicestate
enabled|disabled
/CH/services/http
s
A-12
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
TABLE A-12
Valid Targets
Properties
Values
Default
/CH/services/snmp
engineid
port
sets
traps
v1
v2c
v3
hexadecimal
decimal
enabled|disabled
enabled|disabled
enabled|disabled
enabled|disabled
enabled|disabled
IP address
161
disabled
disabled
disabled
disabled
enabled
/CH/services/snmp/
community/communityname
permissions
ro|rw
ro
/CH/services/snmp/user
/username
authenticationprotocol
authenticationpassword
permissions
privacyprotocol
privacypassword
MD5
string
ro|rw
none|DES
string
MD5
(null string)
ro
DES
(null string)
/CH/clients/ldap
binddn
bindpw
defaultrole
ipaddress
port
searchbase
state
username
string
administrator|operator
ipaddress|none
decimal
string
enable|disabled
(none)
(none)
operator
none
389
(none)
disabled
/CH/clients/servers/[1|2
]
address
IP address|hostname|
none
(none)
/CH/network
commitpending
pendingipaddress
pendingdiscovery
pendingipgateway
pendingipnetmask
true
IP address|none
dhcp|static
IP address|none
IP dotted decimal
(none)
(none)
dhcp
(none)
255.255.255.255
/CH/serial/external
commitpending
flowcontrol
pendingspeed
true
none
decimal from list
(none)
none
9600
/CH/serial/host
commitpending
pendingspeed
true
decimal from list
(none)
9600
Examples
-> set /CH/users/susan role=administrator
Appendix A
A-13
A.2.9
Syntax
show [options] [-display targets|properties|all] [-level
value|all] target [propertyname]
Options
[-d|-display] [-e|examine] [-l|level]
A-14
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Valid Targets
Properties
/CMM
/CH
binddn
bindpw
defaultrole
ipaddress
port
searchbase
state
/CH/clients/ldap
/CH/clients/ntp
/CH/clients/ntp/server
/CH/clients/ntp/server/[1|2]
datetime
usentpserver
/CH/clock
/CH/logs
clear
/CH/logs/event
/CH/logs/event/lis
commitpending
ipaddress
ipdiscovery
ipgateway
ipnetmask
linkstatus
macaddress
pendingipaddress
pendingdiscovery
pendingipgateway
pendingipnetmask
/CH/network
/CH/serial
commitpending
flowcontrol
pendingspeed
speed
/CH/serial/external
Appendix A
A-15
TABLE A-13
Valid Targets
Properties
/CH/serial/host
commitpending
pendingspeed
speed
/CH/services
/CH/services/http
port
secureredirect
servicestate
/CH/services/https
port
servicestate
/CH/services/snmp
ngineid
port
sets
traps
v1
v2c
v3
/CH/services/snmp/communities/
/CH/services/snmp/communities/private
permissions
/CH/services/snmp/communities/public
permissions
/CH/services/snmp/users
/CH/services/ssh
/CH/services/ssh/keys
/CH/services/ssh/keys/dsa
fingerprint
length
publickey
/CH/services/ssh/keys/rsa
fingerprint
length
publickey
/CH/sessions
/CH/sessions/sessionid
starttime
source
type
user
/CH/users
/CH/users/username
A-16
role
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Examples
-> show -display properties /CH/users/susan
/CH/users/susan
Properties:
role = Administrator
TABLE A-14
Appendix A
A-17
TABLE A-14
server
Properties:
Commands:
cd
show
A.2.10
Syntax
start [options] target
Options
[-x|examine] [-h|help] [-state]
Targets
TABLE A-15
Valid Targets
Description
/CMM
/CH/console
Examples
-> start /CH/console
-> start /CMM
A-18
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
A.2.11
Syntax
stop [options] [-script] target
Options
[-x|examine] [-f|force] [-h|help]
Targets
TABLE A-16
Valid Targets
Description
/CMM
/CH/console
Examples
-> stop /CH/console
-> stop -force /CMM
A.2.12
Syntax
version
Appendix A
A-19
Options
[-x|examine] [-h|help]
Example
-> version
version CH firmware version: 1.0.0
CH firmware build number: 4415
CH firmware date: Mon Mar 28 10:39:46 EST 2005
CH filesystem version: 0.1.9
A-20
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
APPENDIX
Ports
Protocols
Applications
22
69
123
161
389
514
546
1812
B-1
Note To manage server modules via the CMM ILOM, you need allow access to all
the ports on the server module SP. TABLE B-2 lists the ports on a typical ILOM service
processor.
TABLE B-2
B-2
Ports
Protocols
Applications
80
443
5120
TCP
5123
TCP
5121
TCP
7578
TCP
22
69
123
161
162
389
LDAP over
UDP/TCP
514
546
623
1812
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007
Glossary
The following terms are used within the Sun server documentation.
A
access control list
(ACL)
address
address resolution
A means for mapping Internet addresses into physical media access control
(MAC) addresses or domain addresses.
Address Resolution
Protocol (ARP)
Administrator
Advanced
Configuration and
Power Interface
(ACPI)
Glossary-1
CPU in response to system load, thus enabling the systems main powerconsuming element (the CPU) to vary its power consumption based on system
load.
Advanced
Programmable
Interrupt Controller
(APIC)
Advanced Technology
Attachment (ATA)
Advanced Technology
Attachment Packet
Interface (ATAPI)
agent
alert
authentication
authorization
AutoYaST
Glossary-2
A device that manages interrupt requests for multiple central processing units
(CPUs). The APIC decides which request has the highest priority and sends an
interrupt to the processor for that request.
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
B
bandwidth
baseboard management
controller (BMC)
baud rate
bind
BIOS (Basic
Input/Output System)
bits per second (bps)
boot loader
C
cache
certificate
Glossary-3
A copy of original data that is stored locally, often with instructions or the
most frequently accessed information. Cached data does not have to be
retrieved from a remote server again when requested. A cache increases
effective memory transfer rates and processor speed.
Public key data assigned by a trusted Certificate Authority (CA) to provide
verification of an entitys identity. This is a digitally signed document. Both
clients and servers can have certificates. Also called a public key certificate.
Certificate Authority
(CA)
client
command-line interface
(CLI)
Common Information
Model (CIM)
console
Coordinated Universal
Time (UTC)
core file
critical event
custom JumpStart
customer-replaceable
unit (CRU)
D
Data Encryption
Standard (DES)
Glossary-4
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
Desktop Management
Interface (DMI)
digital signature
Digital Signature
Algorithm (DSA)
direct memory access
(DMA)
directory server
disk array
disk partition
Distinguished Name
(DN)
Distributed
Management Task Force
(DMTF)
domain
Glossary-5
A consortium of over 200 companies that authors and promotes standards for
the purpose of furthering the ability to remotely manage computer systems.
Specifications from the DTMF include the Desktop Management Interface
(DMI), the Common Information Model (CIM), and the Alert Standard Format
(ASF).
A grouping of hosts that is identified by a name. The hosts usually belong to
the same Internet Protocol (IP) network address. The domain also refers to the
last part of a fully qualified domain name (FQDN) that identifies the company
or organization that owns the domain. For example, sun.com identifies Sun
Microsystems as the owner of the domain in the FQDN docs.sun.com.
domain name
Dynamic Host
Configuration Protocol
(DHCP)
dynamic random-access
memory (DRAM)
The unique name assigned to a system or group of systems on the Internet. The
host names of all the systems in the group have the same domain name suffix,
such as sun.com. Domain names are interpreted from right to left. For
example, sun.com is both the domain name of Sun Microsystems, and a
subdomain of the top-level .com domain.
The server that typically manages host names in a domain. DNS servers
translate host names, such as www.example.com, into Internet Protocol (IP)
addresses, such as 030.120.000.168.
A distributed name resolution system that enables computers to locate other
computers on a network or the Internet by domain name. The system
associates standard Internet Protocol (IP) addresses, such as 00.120.000.168,
with host names, such as www.sun.com. Machines typically get this
information from a DNS server.
A circuit board that holds double the amount of surface-mount memory chips
that a single inline memory module (SIMM) holds. A DIMM has signal and
power pins on both sides of the board, whereas a SIMM has pins on only one
side of the board. A DIMM has a 168-pin connector and supports 64-bit data
transfer.
E
electrically erasable
programmable
read-only memory
(EEPROM)
electrostatic discharge
(ESD)
Glossary-6
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
Ethernet
event
externally initiated
reset (XIR)
A signal that sends a soft reset to the processor in a domain. XIR does not
reboot the domain. An XIR is generally used to escape from a hung system in
order to reach the console prompt. A user then can generate a core dump file,
which can be useful in diagnosing the cause of the hung system.
F
failover
Fast Ethernet
fdisk partition
Fibre Channel (FC)
Glossary-7
The automatic transfer of a computer service from one system, or more often a
subsystem, to another to provide redundant capability.
Ethernet technology that transfers data up to 100M bits per second. Fast
Ethernet is backward compatible with 10M-bit per second Ethernet
installations.
A logical partition of a physical disk drive that is dedicated to a particular
operating system on an x86-based system.
A connector that provides high bandwidth, increased distance, and additional
connectivity from hosts to peripherals.
field-replaceable unit
(FRU)
file system
firewall
A 100-Mbyte per second loop topology used with Fibre Channel that enables
connection of multiple devices such as disk drives and controllers. An
arbitrated loop connects two or more ports, but allows only two ports to
communicate at a given time.
A system component that is replaceable at the customer site.
A consistent method by which information is organized and stored on physical
media. Different operating systems typically have different file systems. File
systems are often a tree-structured network of files and directories, with a root
directory at the top and parent and child directories below root.
A basic Internet protocol based on Transmission Control Protocol/Internet
Protocol (TCP/IP) that enables the retrieving and storing of files between
systems on the Internet without regard for the operating systems or
architectures of the systems involved in the file transfer.
A network configuration, usually both hardware and software, that protects
networked computers within an organization from outside access. A firewall
can monitor or prohibit connections to and from specified services or hosts.
firmware
Software that is typically used to help with the initial booting stage of a system
and with system management. Firmware is embedded in read-only memory
(ROM) or programmable ROM (PROM).
flash PROM
G
gateway
Gigabit Ethernet
Glossary-8
A computer or program that interconnects two networks and then passes data
packets between the networks. A gateway has more than one network
interface.
Ethernet technology that transfers data up to 1000M bits per second.
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
Grand Unified
Bootloader (GRUB)
graphical user interface
(GUI)
A boot loader that can install two or more operating systems (OS) onto a single
system and that can manage which OS to boot at power-on.
An interface that uses graphics, along with keyboard and mouse, to provide
easy-to-use access to an application.
H
heatsink
host
host ID
host name
The name of a particular machine within a domain. Host names always map to
a specific Internet Protocol (IP) address.
hot plug
hot swap
Hypertext Transfer
Protocol (HTTP)
Hypertext Transfer
Protocol Secure
(HTTPS)
Glossary-9
Part of the 32-bit Internet Protocol (IP) address used to identify a host on a
network.
The Internet protocol that retrieves hypertext objects from remote hosts. HTTP
messages consist of requests from client to server and responses from server to
client. HTTP is based on Transmission Control Protocol/Internet Protocol
(TCP/IP).
An extension of HTTP that uses Secure Sockets Layer (SSL) to enable secure
transmissions over a Transmission Control Protocol/Internet Protocol
(TCP/IP) network.
I
in-band system
management
install server
Integrated Lights Out
Manager (ILOM)
Intelligent Platform
Management Interface
(IPMI)
Internet Control
Message Protocol
(ICMP)
interrupt request
(IRQ)
Glossary-10
Server management capability that is enabled only when the operating system
is initialized and the server is functioning properly.
A server that provides the Solaris software DVD or CD images from which
other systems on a network can install the Solaris software.
An integrated hardware, firmware, and software solution for in-chassis or inblade system management.
A hardware-level interface specification that was designed primarily for outof-band management of server systems over a number of different physical
interconnects. The IPMI specification describes extensive abstractions
regarding sensors. This enables a management application running on the
operating system (OS) or in a remote system to comprehend the environmental
makeup of the system and to register with the systems IPMI subsystem to
receive events. IPMI is compatible with management software from
heterogeneous vendors. IPMI functionality includes Field Replacable Unit
(FRU) inventory reporting, system monitoring, logging, system recovery
(including local and remote system resets and power on and off capabilities),
and alerting.
An extension to the Internet Protocol (IP) that provides for routing, reliability,
flow control, and sequencing of data. ICMP specifies error and control
messages used with the IP.
The basic network layer protocol of the Internet. IP enables the unreliable
delivery of individual packets from one host to another. IP does not guarantee
that the packet will be delivered, how long it will take, or if multiple packets
will be delivered in the order they were sent. Protocols layered on top of IP
add connection reliability.
In Transmission Control Protocol/Internet Protocol (TCP/IP), a unique 32-bit
number that identifies each host or other hardware system on a network. The
IP address is a set of numbers separated by dots, such as 192.168.255.256,
that specifies the actual location of a machine on an intranet or the Internet.
A signal that a device requires attention from the processor.
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
IPMItool
J
Java(TM) Web Start
application
JumpStart
installation
A web application launcher. With Java Web Start, applications are launched by
clicking on the web link. If the application is not present on your system, Java
Web Start downloads it and caches it onto your system. Once an application is
downloaded to its cache, it can be launched from a desktop icon or browser
link. The most current version of the application is always presented.
A type of installation in which the Solaris software is automatically installed
on a system by using the factory-installed JumpStart software.
K
kernel
Keyboard Controller
Style (KCS) interface
keyboard, video,
mouse, storage
(KVMS)
Glossary-11
The core of the operating system (OS) that manages the hardware and provides
fundamental services, such as filing and resource allocation, that the hardware
does not provide.
A type of interface implemented in legacy personal computer (PC) keyboard
controllers. Data is transferred across the KCS interface using a per-byte
handshake.
L
lights out management
(LOM)
Lightweight Directory
Access Protocol
(LDAP)
Lightweight Directory
Access Protocol (LDAP)
server
A directory service protocol used for the storage, retrieval, and distribution of
information, including user profiles, distribution lists, and configuration data.
LDAP runs over Transmission Control Protocol/Internet Protocol (TCP/IP)
and across multiple platforms.
A software server that maintains an LDAP directory and service queries to the
directory. The Sun Directory Services and the Netscape Directory Services are
implementations of an LDAP server.
A boot loader for Linux.
A group of systems in close proximity that can communicate via connecting
hardware and software. Ethernet is the most widely used LAN technology.
The processor or system on which a software application is running.
M
major event
Management
Information Base
(MIB)
man pages
Glossary-12
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
N
namespace
node
nonmaskable interrupt
(NMI)
Glossary-13
nonvolatile memory
nonvolatile randomaccess memory
(NVRAM)
A type of memory that ensures that data is not lost when system power is off.
O
object identifier
(OID)
OpenBoot(TM) PROM
A layer of software that takes control of an initialized system after the poweron self-test (POST) successfully tests components. OpenBoot PROM builds
data structures in memory and boots the operating system.
OpenIPMI
Operator
out-of-band (OOB)
system management
P
parity
partition
Peripheral Component
Interconnect (PCI)
Peripheral Interface
Controller (PIC)
Glossary-14
A method used by a computer for checking that data received matches data
sent. Also refers to information stored with data on a disk that enables the
controller to rebuild data after a drive failure.
A physical section on a hard disk drive.
A local bus standard used to connect peripherals to 32-bit or 64-bit systems.
An integrated circuit that controls peripherals in an interrupt request (IRQ)driven system, taking away that load from the central processing unit (CPU).
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
permissions
physical address
Platform Event Filtering
(PEF)
port
port number
power cycling
power-on self-test
(POST)
PowerPC
Preboot Execution
Environment (PXE)
Glossary-15
A standard for Internet electronic mail that encrypts data to ensure privacy
and data integrity.
A memory chip on which data can be programmed only once and which
retains the program forever. PROMs retain data even when power is off.
A set of rules that describes how systems or devices on a network exchange
information.
A mechanism whereby one system acts on behalf of another system in
responding to protocol requests.
A cryptographic method that uses a two-part key (code) that is made up of
public and private components. To encrypt messages, the published public
keys of the recipients are used. To decrypt messages, the recipients use their
unpublished private keys, which are known only to them. Knowing the public
key does not enable users to deduce the corresponding private key.
R
rack unit (U)
random-access memory
(RAM)
read-only file
read-only memory
(ROM)
real-time clock (RTC)
reboot
Glossary-16
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
redirection
redundant array of
independent disks
(RAID)
Remote Management
and Control Protocol
(RMCP)
remote procedure call
(RPC)
remote system
reset
root
A collection of tools developed by Red Hat, Inc. for Red Hat Linux that can
automate the install, uninstall, update, verify, and query software processes on
a computer. RPM is now commonly used by multiple Linux vendors.
The channeling of input or output to a file or device rather than to the standard
input or output of a system. The result of redirection sends input or output
that a system would normally display to the display of another system.
RAID enables a set of disk drives to appear as a single logical disk drive to an
application such as a database or file system. Different RAID levels provide
different capacity, performance, high availability, and cost characteristics.
root directory
The base directory from which all other directories stem, either directly or
indirectly.
router
A system that assigns a path over which to send network packets or other
Internet traffic. Although both hosts and gateways do routing, the term
router commonly refers to a device that connects two networks.
RSA algorithm
schema
Glossary-17
S
Secure Shell (SSH)
A UNIX shell program and network protocol that enables secure and
encrypted log in and execution of commands on a remote system over an
insecure network.
A protocol that enables client-to-server communication on a network to be
encrypted for privacy. SSL uses a key exchange method to establish an
environment in which all data exchanged is encrypted with a cipher and
hashed to protect it from eavesdropping and alteration. SSL creates a secure
connection between a web server and a web client. Hypertext Transfer Protocol
Secure (HTTPS) uses SSL.
To facilitate dynamic discovery of features, the Intelligent Platform
Management Interface (IPMI) includes this set of records . They include
software information, such as how many sensors are present, what type they
are, their events, threshold information, and so on. The sensor data records
enable software to interpret and present sensor data without any prior
knowledge about the platform.
A point-to-point serial peripheral interface that links controllers directly to
disk drives. SAS devices include two data ports that enable failover
redundancy, which guarantees data communication through a separate path.
serial console
A terminal or a tip line connected to the serial port on the service processor. A
serial console is used to configure the system to perform other administrative
tasks.
server certificate
Glossary-18
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
interface to the system event log (SEL). Typical functions of the SP are to
measure processor temperature, power supply values, and cooling fan status.
The SP can take autonomous action to preserve system integrity.
session time-out
Simple Mail Transfer
Protocol (SMTP)
Simple Network
Management Protocol
(SNMP)
Small Computer
System Interface
(SCSI)
A simple protocol used to exchange data about network activity. With SNMP,
data travels between a managed device and a network management station
(NMS). A managed device can be any device that runs SNMP, such as hosts,
routers, web servers, or other servers on the network.
subnet
A working scheme that divides a single logical network into smaller physical
networks to simplify routing. The subnet is the portion of an Internet Protocol
(IP) address that identifies a block of host IDs.
subnet mask
A bit mask used to select bits from an Internet address for subnet addressing.
The mask is 32 bits long and selects the network portion of the Internet address
and one or more bits of the local portion. Also called an address mask.
superuser
Glossary-19
A log that provides nonvolatile storage for system events that are logged
autonomously by the service processor or directly with event messages sent
from the host.
T
Telnet
threshold
time-out
transmission control
block (TCB)
Transmission Control
Protocol/Internet
Protocol (TCP/IP)
trap
The virtual terminal program that enables the user of one host to log in to a
remote host. A Telnet user of one host who is logged in to a remote host can
interact as a normal terminal user of the remote host.
Minimum and maximum values within a range that sensors use when
monitoring temperature, voltage, current, and fan speed.
A specified time after which the server should stop trying to finish a service
routine that appears to be hung.
Part of the Transmission Control Protocol/Internet Protocol (TCP/IP) that
records and maintains information about the state of a connection.
An Internet protocol that provides for the reliable delivery of data streams
from one host to another. TCP/IP transfers data between different types of
networked systems, such as systems running Solaris, Microsoft Windows, or
Linux software. TCP guarantees delivery of data and that packets will be
delivered in the same sequence in which they were sent.
Event notification made by Simple Network Management Protocol (SNMP)
agents by their own initiative when certain conditions are detected. SNMP
formally defines seven types of traps and permits subtypes to be defined.
A simple transport protocol that transfers files to systems. TFTP uses User
Datagram Protocol (UDP).
U
uninterruptible power
supply (UPS)
Glossary-20
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
unshielded twisted
pair/shielded twisted
pair (UTP/STP)
user account
User Datagram Protocol
(UDP)
user identification
(userid)
user identification
number (UID
number)
user name
The number assigned to each user accessing a UNIX system. The system uses
UID numbers to identify, by number, the owners of files and directories.
A combination of letters, and possibly numbers, that identifies a user to the
system.
V
voltage regulator
module (VRM)
volume
volume manager
W
W3C
Glossary-21
web server
X
X.509 certificate
X Window System
Glossary-22
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular
Index
C
case, 3-1
CLI
command
syntax, A-1
commands
access settings, A-3
cd, A-5
character case, 3-1
clock settings, A-5
command verbs overview, 3-2
create, A-6
delete, A-7
displaying, 5-8
exit, A-8
help, A-8
host, A-4
load, A-10
miscellaneous, A-2
network and serial port, A-3
options, 3-3
reset, A-11
set, 5-3, A-12
show, A-14
SNMP, A-4
start, A-18
stop, A-19
user, A-2
version, A-19
namespaces, 3-1
privilege levels, 3-2
clock, A-2
settings, 5-3, A-5
CMM ILOM
and LDAP, 7-1 to 7-5
CMM ILOM ports, B-1
D
default root password, 2-4
E
event log
clearing, 6-4
viewing, 6-4
F
firewall
configuring, B-1
I
ILOM
CLI
static IP, Ethernet, 1-8, 2-7
managing network settings, 5-1
managing user accounts, 4-2
namespaces, 3-1
serial connection, 2-2
M
MAC address, 2-3, 2-6
Management Information Base (MIB)
description of, 9-2
N
NTP, configuring, 5-3
Index-1
P
password, root, 2-4
ports, B-1
R
root password, 2-4
S
SNMP, 9-1 to 9-6
and MIB, 9-2
management software, 9-3
overview, 9-1
Port, Standard (161), 9-3
user accounts
adding, 9-5
configuring, 9-5
deleting, 9-5
properties, 9-6
v1, v2c, v3, 9-6
specifications, system, B-1
system specifications, B-1
U
user privilege levels, 3-2
V
viewing
event log, 6-4
Index-2
Integrated Lights Out Manager (ILOM) Administration Guide for Sun Blade 6000 Modular System April 2007