COMMISSIONING INPUT
FOR
ATMOSPHERIC FLUIDISED BED COMBUSTION BOILER
THERMAX LTD.,
BOILERS AND HEATERS GROUP,
PUNE, INDIA.
Prelim
Rev.
21.11.2013
Date
Details
R.Kshirsagar
Atul Zade
Deputy Executive
Assit.Manager
HOD - Solid
SBU
Prepared By
Reviewed By
Approved By
COMMISSIONING INPUT
PAGE 1
THERMAX LIMITED
BOILER & HEATER GROUP
PUNE, INDIA.
COMMISSIONING INPUTS
CUSTOMER: POWER A/C RAICHUR BIO ENERGY PVT LTD
JOB NO.
: PD0581
BOILER
: 40 TPH, 66 KG/CM2 (G), 490 5 C BI DRUM AFBC BOILER
1. QUANTITY OF FIRE WOOD FOR REFRACTORY DRY OUT:
Particulars
Quantity
Dry Wood
Size
: 20 tons
: 2 dia & 2 feet long
2. QUANTITY OF CHEMICALS FOR ALKALI BOILOUT (PER BOILER, PER BOIL OUT)
Details of Chemicals
Hydrous trisodium phosphate
(Na3PO4 12H2O)
Anhydrous di sodium phosphate
(Na2 HPO4)
Wetting Agent
(Surfactant/Detergent)
Quantity
140 Kg
30 Kg
8 LTR
(Total requirement)
Quantity
Charcoal
730 Kg
Diesel
30 LTR
PAGE 2
THERMAX LIMITED
BOILER & HEATER GROUP
PUNE, INDIA.
5.
:
:
:
Percentage limits
55-60
37-40
<2.0
<2.0
Traces
0.54
0.23
0.08
0.22
0.45
1050-1100 Kg/m3
> 1300 C
Sub Angular / Spherical
OTHERS:
Requirement
Input Detail
Electric power
@7kg/ cm2
For instrument line flushing
Service Air
Instrument air
Remarks
For Commissioning and load trials of
Auxiliaries, Consider the start up peak current
while deciding DG (if employed).
Feed water
Cooling water
Area & equipment
lighting
~1100 Tons
Operating staff
COMMISSIONING INPUT
PAGE 3
THERMAX LIMITED
BOILER & HEATER GROUP
PUNE, INDIA.
6.
ELECTRICAL POWER
Parameters
For LT motors
Voltage
Frequency
Type
For Instrumentation
Voltage for solenoid valve
Voltage for transmitters
Emergency Drives
7.
Units
Value
V
Hz
415 10%
50 5%
AC, 3 Phase, 4 WIRE
V
V
V
110 V AC
24 V DC
220V DC
Feed Water :
S.N
1
2
3
4
5
6
7
9
10
8.
Parameter
Hardness
pH at 25 0C
Oxygen
Total iron(Fe)
Copper (Cu)
Total silica (SiO2)
Total dissolved solid
Hydrazine reisdual
Oil, Organic matter
Unit
Quantity
Nil
8.5 to 9.0
0.007
<0.02
<0.015
<0.05
ppm
ppm
ppm
ppm
ppm
ppm
<1.0
0.01-0.03
<3
ppm
ppm
Fuel
Ultimate analysis:
S.N
1
2
3
4
5
6
7
9
Parameter
Carbon
Hydrogen
Sulphur
Oxygen
Nitrogen
Moisture
Ash
GCV
COMMISSIONING INPUT
Unit
%
%
%
%
%
%
%
%
Rice husk
36.67
4.57
0.18
32.88
1.25
9.44
Indian Coal
37.10
2.30
0.30
6.60
0.70
8.00
Dolochar
34.00
0.75
0.30
3.00
0.78
8.00
15.01
3125
45.00
3500
53.17
3000
PAGE 4
THERMAX LIMITED
BOILER & HEATER GROUP
PUNE, INDIA.
Fuel Sizing :
Rice husk : AS received stone and mud free
Coal
: < 3 mm = 35 %
<1 mm = 15%
< 6 mm = 100%
8.
Lubrication Quantity
LUBRICANTS
LITHON 3 (HP) OR EQUI.
SERVOSYSTEM 46 OR ISO VG 46 OIL EQUI.
OIL - SERVOMESH 50 OR ENKLO 140
GREASE - NLGI 3 (UNIREX-N3) OR EQUIVALENT GRADE
GREASE - SERVOGEM EP-2
VG 220
COMMISSIONING INPUT
QUANTIY
15 KG
10 LTR
10 LTR
5 KG
10 KG
25 LTR
PAGE 5