Professional Documents
Culture Documents
EDU-LABS DIDACTIC
Automatic Washing Machine
Experiments Module
PLC-EM01
Experiments Manual
EDU-LABS DIDACTIC
www.scienscope.com.my
Module Diagram
EDU-LABS DIDACTIC
www.scienscope.com.my
EDU-LABS DIDACTIC
www.scienscope.com.my
EDU-LABS DIDACTIC
www.scienscope.com.my
Ladder Diagram
EXPERIMENT PROCEDURE:
1. Open PLC Ladder Programming Software ( FPWIN GR2 ) as shown in figure
below, follow the step :(a) Click START ALL PROGRAMS PANASONIC-EW CONTROL
FPWIN GR 2 FPWIN GR
EDU-LABS DIDACTIC
www.scienscope.com.my
(c) When the FPWIN GR is open, dialog box pop up as shown below and
select NEW for new program.
EDU-LABS DIDACTIC
www.scienscope.com.my
(e) After select OK, then you can start your programming in the new FPWIN
file.
2. Connect the Interfacing cable to computer
3. Wiring the test lead from Automatic Washing Machine Experiments Module to
PLC-FPO30 Trainer as shown in figure below :
EDU-LABS DIDACTIC
www.scienscope.com.my
Wiring Experiment
EDU-LABS DIDACTIC
www.scienscope.com.my
OUTPUT PORT
Y0
Y1
Y2
Y3
Y4
Y5
CONNECTION
START
STOP
LOWER LIMIT
UPPER LIMIT
DRAIN
Table 1: Input List
CONNECTION
INTAKE
DRAIN
FORWARD STIRRING
REVERSE STIRRING
DRYING BARREL
BUZZER
Table 2: Output List
ADDRESS
X0
X1
X2
X3
X4
ADDRESS
Y0
Y1
Y2
Y3
Y4
Y5
Click Download
to PLC
EDU-LABS DIDACTIC
www.scienscope.com.my
Click YES to
proceed
(c) When downloading begins, the program will be automatically placed in the
monitoring mode.
6.
EDU-LABS DIDACTIC
www.scienscope.com.my
When the water reached to the Upper Limit Sensor, sensor will ON and automatically will
ON the Stirring Wheel to start turn.
3) When the Stirring Wheel stop turning, the Drain Water Indicator Valve will open and
remove all the water from washing machine.
4) At the same time, drying barrel will be ON for 5 seconds to dry the clothes.
5) When the water reached to the Lower Limit Sensor, sensor will ON and automatically
Intake Electromagnetic Valve will open to flow the new water to the washing machine.
6) Repeat steps 2-4 for 2 times.
7) When the water reached to the Lower Limit Sensor, sensor will ON for the third times,
Buzzer Indicator will be ON and OFF automatically for 3 times, and finally the whole
process is over.
EDU-LABS DIDACTIC
10
www.scienscope.com.my
Solution provider for scientific and technical education training system since 2000
EDU-LABS DIDACTIC
11
www.scienscope.com.my