You are on page 1of 18

HTTP://WWW.THEPRESCON.

COM
R

PRECISION
ENGINEERING
SERVICES & CONSULTANCY COMPANY

Asset management solution providers

Company Profile
Testing Services

PRESCON
PROFILE

Power System Analysis


Transformer Management
Plant Management
Switch Yard Management
Motor Management
Generator Management
Turnkey Project Procurement

ABOUT US
YO U R P O W E R PA R T N E R

Our Vision
Prescons presence is to provide
reliable Asset Management Solutions,
which best fit the industrial needs
and to provide best support and
maintenance services.

ENGINEERING SERVICES
& CONSULTANCY

.
.
S
O
L
U
T
I

Precision Engg Services & Consultancy co.

PRECISION ENGINEERING SERVICES


& CONSULTANCY COMPANY
Precision Engineering Services & Consultancy Company (PRESCON)
has been formed in 2004. The company has a distinguished heritage of
introducing Worlds best Asset Management Solutions in Pakistan
specifically in power sector and generally for all major industrial sectors.
Over a period of time our Products & Services have gained a steady &
widespread acceptance in Power Generation, Cement, Oil & Gas, Textile
and other major industrial sectors.
Now we must say that with a wide range of turnkey solutions including
both products and engineering services, we can always promise a
competitive and healthy proposal for you.
We are in technological partnership with some International key players,
of course this brings a value to our portfolio, experience and database.
We have introduced them in Pakistan through different workshops
and seminars conducted by Prescon at regular basis.
We are here in market to be known as one of the best solutions providers
and trustworthy resource for Project Management, Plant Asset Mgmt,
Turnkey Project Supplies, Manufacturing/ Fabrication and Training
Services.

O
N
S

info@theprescon.com

Http://www.theprescon.com

WHY PRESCON
YO U R P O W E R PA R T N E R

Our Mission
As, we grow we want to remain focused on
our mission all the way through: which is to
contribute towards our nations industrial
growth by making power generation,
transmission and distribution reliable.
Educate the industry professional and
introduce asset management concepts
propose complete solutions and
provide quality services to our clients

When you pass


it to Prescon
consider it done

.
.
S
O
L
U
T
I
O
N

CONTACT

OUR CAPABILITIES

Info@theprescon.com
sales@theprescon.com
www.theprescon.com
Suite S-8,S-9
Rukshanda Heights
8km Multan Road
Lahore - 54500
Pakistan

Qualified and experienced engineers.


NETA, IEEE, ISA Membership
E-library containing up-to-date standards from
IEC, IEEE/ ANSI, CIGRE, ISA, ASTM, ASME, API,
ASHARE etc and handbooks on Reliability
Maintenance, Reliability Engineering, Plant
Design, Rotary Equipment Maintenance & Repair,
Transformer Operation & Maintenance, Circuit
Breaker Diagnostics
& Repair, Protection
Relays & Metering Testing , Operation &
Maintenance Philosophies, IEEE Color Book series,
etc.
Doble services agreement which gives us
access to 80+ yrs of equipment testing
database & all proceedings of various Doble
Technical Committee meetings on
Transformers, Breakers, Relays & Rotary
Equipment.
SOPs for Testing.
Power System Analysis ETAP software
SAM - Solar Power design & Analysis software

+92 42 744 0381-2


+92 42 744 0383 (Fax)

info@theprescon.com

Http://www.theprescon.com

PRESCON SERVICES
TESTING SERVICES

OVERVIEW

Prescon has Calibration Technicians, Report Writers,


Engineers and other workforce available to provide
necessary support and documentation. This support
assures our field crews and customers that all
equipment is accurate and dependable, reports are
professional and comprehensive, and that we are
completely capable of accomplishing any testing and
maintenance project in a timely manner.

Prescon is an independent testing and verification firm with substantial experience in electrical
maintenance testing, acceptance testing and engineering evaluations of electrical generation,
transmission & distribution equipment.
Our Engineers & Technicians serve major utility, industrial, commercial and institutional clients
low voltage, medium voltage, high voltage and extra-high voltage testing and maintenance
needs; provide engineering services, and repair of all manufacturers power equipment
.
Prescon is a NETA member company specializing in the electrical testing of Switchgear,
Substations, Power & Distribution Transformers, Generators, Motors, Relays and Circuit
Breakers, etc

We have a complete
Library of

IEC
ANSI
NEMA MG
NETA

.
S
O
L
U

All tests are


performed in
accordance with
relevant standards

OUR TESTING EQUIPMENT


1.
2.
3.
4.
5.
6.

T
I
O

12 KV C&DF Equipment
Transformer Leakage Reactance Set
SFRA For Transformer
Turns Ratio Set
Winding Resistance Test Set
Resonator for Power Factor Tip-up
Testing of Generators and Motors
7. Megger/ Insulation Resistance Set
8. Oil Power Factor Set
10. Protection Relay Test Set
11. Meter / Transducer Test Set
Class 0.2 Accuracy
12. PQ Test Set.
13. DLRO - Low Resistance Ohmmeter

14. Breaker Timing Test Set


15. AC/ DC HiPot.
16. Partial Discharge Test Kit for
Generators & Motors
17. Transformer / CT/ PT Excitation
Current Test Set
18. Variable Autotransformer
19. Temperature Bath 40 to 650 C
20. Multifunction Calibrator

N
S

info@theprescon.com

Http://www.theprescon.com

PRESCON SERVICES
MAJOR AREAS
P O W E R S Y S T E M A N A LY S I S
Prescon offers a complete power system
analysis services though ETAP which is
worlds most widely used power system
analysis tool

Load Flow
Short Circuit
Motor/ generators startup
& Transient Stability
Studies
Protective Device Coordination
Harmonic Study
Arc Flash Hazard Analysis

TRANSFORMER MANAGEMENT
Power and Distribution Transformers are vital components of a Power Supply
System. With high costs and long lead times, it is important to formulate an
effective PdM program for periodic condition assessment of your asset.
Prescon is the only company in Pakistan to offer complete range of field
testing for transformers.

PLANT MANAGEMENT
With support from companies like Doble, OTI, TWI and others, Prescon offers
full Plant Asset Management Services. Our services include but are not limited
to electrical, instrumentation, mechanical and process equipment for power
generation, oil and gas, chemical, petrochemical, cement, sugar & textile
industries.

C O M P L E T E S W I T C H YA R D M A N A G E M E N T
Prescon has the tools and necessary experience to offer testing services for
switchyard equipment which includes CT/PTs, CCVTs, Line Traps, Surge
Arrestors, Transformers, Circuit Breakers, Isolators / Dis-connecters, Earth
Switches, Protection Relays, Meters, Transducers, Complete UPS, Batteries,
Battery Chargers, SCADA, PLC etc.
Prescon also offers overhead connection tightening, Partial Discharge for GIS,
AIS, Transformers and thermography survey services.

R O T A RY E Q U I P M E N T M A N A G E M E N T
MOTOR MANAGEMENT

Prescon provides complete motor care PdM program for all of your LV and
MV Motors. Our testing services include Insulation Resistance, PI, Winding
Resistance, Power Factor Tip-up, Partial Discharge, AC/DC Hipot, Corna / TVA
Probe, etc.Prescon also provides services for motor stator and rotor cleaning,

.
S

G E N E R AT O R M A N A G E M E N T

O
L
U
T
I
O

It is desirable during power generator shutdowns to test the generator stator


and rotor of Steam & Gas Turbine and IC Engines Generators for electrical
properties. Prescon can offer generator rotor drawout and inspection
services complete with testing of each component.Precision Engineering
Services & Consultancy company has the equipment and expertise to
perform complete testing and inspection at almost all generators.

N
S

info@theprescon.com

Http://www.theprescon.com

PRESCON
POWER SERVICES

POWER SYSTEM ANALYSIS


The power systems analysis
experts at Prescon enable efficient,
economical use of power by using
field measurements and computer
modeling to analyze
power system

Applications
- Electrical Power Systems
- Mining, petrochemical, industrial and utility sectors
Benefits
- Economical and efficient use of power
- Reliable supply of power during system operation
- Reduced operation costs

Features
- Detailed reporting.
Voltage, Current & power factor
at various locations in the system
- Total system approach for complete & thorough
evaluation
- Reliable supply of power during system operation
- Reduced operation costs

OVERVIEW
Electrical Equipment Asset Management life cycle starts with
professionally and carefully designed electrical system, from
the initial conceptual stage.
It incorporates a load flow study, short circuit analysis to
determine equipment ratings and specifications.
Computer aided protective device coordination study ensures
a reliable, dependable and secure protection scheme for the
electrical system.
Arc flash hazard analysis are also carried out to determine the
level of PPE required by the maintenance staff for personnel
safety.

.
.
S
O

Motor acceleration generation startup & transient stability


studies would ensure that motor starting does not result in
depressed voltages for a longer period duration.
The generators go through a trouble free loading and system is
stable enough on external faults and switching events.

L
U
T
I
O

Prescon offers complete power system analysis


services using ETAP which is worlds most widely
used power system analysis tool

N
S

info@theprescon.com

Http://www.theprescon.com

PRESCON
POWER SERVICES

POWER SYSTEM ANALYSIS

TYPICAL POWER SYSTEM ANALYSIS

Load Flow
Short Circuit
Motor/ generators startup
& Transient Stability
Studies
Protective Device Coordination
Harmonic Study
Arc Flash Hazard Analysis
LOAD FLOW STUDIES
Load flow
A base study is performed to determine the steadystate operating characteristics of the electrical
system.
Transient motor starting
This study examines how the electrical system will
react when individual motors are started or when
groups of motors are started simultaneously.
Short circuit
The calculations of fault-current levels at all buses
in the system are studied to minimize the
consequences of a potential short circuit in the
system.
Protective device coordination study
Protective devices, such as circuit breakers, fuses,
and relays, are examined and properly coordinated
to protect personnel and equipment.
.
.
S
O

Harmonic study
This study is recommended on systems that have
20% or more nonlinear loading produced by
equipment such as variable-speed drives, arc
welders, and fluorescent ballasts.

One of the most common computational procedures used in


power system analysis is the load flow calculation. The
planning, design, and operation of power systems require such
calculations to analyze the steady-state (quiescent)
performance of the power system under various operating
conditions and to study the effects of changes in equipment
configuration.
These load flow solutions are performed using computer
programs designed specifically for this purpose. The basic load
flow question is this: Given the load power consumption at all
buses of a known electric power system configuration and the
power production at each generator, find the power flow in
each line and transformer of the interconnecting network and
the voltage magnitude and phase angle at each bus.
Analyzing the solution of this problem for numerous conditions
helps ensure that the power system is designed to satisfy its
performance criteria while incurring the most favorable
investment and operation costs.
Some examples of the uses of load flow studies are to
determine the following:

L
U
T
I
O

Component or circuit loadings


Steady-state bus voltages
Reactive power flows
Transformer tap settings
System losses
Generator exciter/regulator voltage set points
Performance under emergency conditions

N
S

info@theprescon.com

Http://www.theprescon.com

PRESCON
POWER SERVICES

POWER SYSTEM ANALYSIS

TYPICAL POWER SYSTEM ANALYSIS

Load Flow
Short Circuit
Motor/ generators startup
& Transient Stability
Studies
Protective Device Coordination
Harmonic Study
Arc Flash Hazard Analysis
SHORT CIRCUIT STUDIES
Electrical power systems are, in general, fairly complex systems
composed of a wide range of equipment devoted to generating,
transmitting, and distributing electrical power to various
consumption centers. The very complexity of these systems suggests
that failures are unavoidable, no matter how carefully these systems
have been designed. The feasibility of designing and operating a
system with zero failure rate is, if not unrealistic, economically
unjustifiable. Within the context of short-circuit analysis, system
failures manifest themselves as insulation breakdowns that may lead
to one of the following phenomena:
Undesirable current flow patterns
Appearance of currents of excessive magnitudes that could lead to
equipment damage and downtime
Excessive over-voltages, of the transient and/or sustained nature,
that compromise the integrity and reliability of various insulated
parts
Voltage depressions in the vicinity of the fault that could adversely
affect the operation of rotating equipment
Creation of system conditions that could prove hazardous to
personnel because short circuits cannot always be prevented, we can
only attempt to mitigate and to a certain extent contain their
potentially damaging effects. One should, at first, aim to design the
system so that the likelihood of the occurrence of the short circuit
becomes small. If a short circuit occurs, however, mitigating its
effects consists of a) managing the magnitude of the undesirable
fault currents, and b) isolating the smallest possible portion of the
system around the area of the mishap in order to retain service to the
rest of the system.

A significant part of system protection is devoted to detecting shortcircuit conditions in a reliable fashion. Considerable capital
investment is required in interrupting equipment at all voltage levels
that is capable of withstanding the fault currents and isolating the
faulted area.
It follows, therefore, that the main reasons for performing shortcircuit studies are the following:
Verification of the adequacy of existing interrupting equipment. The
same type of studies will form the basis for the selection of the
interrupting equipment for system planning purposes.
Determination of the system protective device settings, which is
done primarily by quantities characterizing the system under fault
conditions. These quantities also referred to as protection handles,
typically include phase and sequence currents or voltages and rates
of changes of system currents or voltages.
-Determination of the effects of the fault currents on various system
components such as cables, lines, busways, transformers, and
reactors during the time the fault persists. Thermal and mechanical
stresses from the resulting fault currents should always be compared
with the corresponding short-term, usually first-cycle, withstand
capabilities of the system equipment.
-Assessment of the effect that different kinds of short circuits of
varying severity may have on the overall system voltage profile.
These studies will identify areas in the system for which faults can
result in unacceptably widespread voltage depressions.
-Conceptualization, design and refinement of system layout, neutral
grounding, and substation grounding.

info@theprescon.com

Http://www.theprescon.com

PRESCON
POWER SERVICES

POWER SYSTEM ANALYSIS

TYPICAL POWER SYSTEM ANALYSIS

Load Flow
Short Circuit
Motor/ generators startup
& Transient Stability
Studies
Protective Device Coordination
Harmonic Study
Arc Flash Hazard Analysis
RELAY COORDINATION STUDIES
An important step in the design of any power distribution system is
the time-current coordination of all over-current protective devices
required for the protection of the system and the connected
equipment. When a short circuit or an abnormal power flow occurs
for a sustained period of time, the protective devices should react to
isolate the problem with minimum disruption to the balance of the
system. This is the goal of a well-coordinated electrical power
system.
The operation of protective devices can be estimated by graphic
representation of the time-current characteristics curves (TCCs) of
these devices. By plotting these characteristics on a common graph,
the relationship of the characteristics among the devices is
immediately apparent. Any potential trouble spots, such as
overlapping of curves or unnecessarily long time intervals between
devices, are revealed. By indicating on the current scale the
maximum and minimum value of short-circuit currents (three-phase
and line-to-ground) that can occur at various points in the circuit, the
operation of circuit protective devices can be estimated for various
fault conditions. An accompanying single-line diagram can indicate
the components and define their location in the circuit.
The time-honored method of plotting these curves is to superimpose
a transparent sheet of graph paper over the manufacturer's
published curves on an illuminated drafting table. When the time
scales have been carefully matched and the current scales adjusted,
the curve is traced onto the graph paper using a French curve or
flexible spline. The process is then repeated for the remaining
protective devices

Damage curves for equipment, such as motors, transformers, and


cables, are also plotted to assess the level of protection provided for
the equipment and to provide a graphical representation of the
protection achieved. This process can be both tedious, time
consuming, and prone to error.
Since the selection of device parameters follows well-defined rules,
for the most part, computer programs are available for the task of
producing these curves.
The information needed to perform a coordination study is a single
line diagram showing the following:
Protective device manufacture and type
Protective device ratings
Trip settings and available range
Short-circuit current at each system bus (three-phase and line-toground)
Full load current of all loads
Voltage level at each bus
Transformer kVA, impedance, and connections (delta-wye, etc.)
Current transformer (CT) and potential transformer (PT) ratios
Cable size, conductor material, and insulation
All sources and ties

info@theprescon.com

Http://www.theprescon.com

PRESCON SERVICES
TESTING RANGE

TRANSFORMER MANAGEMENT
Prescons presence is to provide
reliable Asset Management Solutions,
which best fit the industrial needs
and to provide best support and
maintenance services.

ITS TIME FOR A COMPLETE


AND COMPREHENSIVE
TESTING

Power Factor
Transformer Turn Ratio
Core Excitation
Winding Resistance
Current Transformer Ratio
& Polarity
Insulation Resistance
SFRA
Dissolved Gas Analysis
General Chemistry Analysis
Furanic Analysis
Metals in Oil
Particle Count
Degree of Polymerization
Online Monitoring
Leakage Reactance

PTTS-100101
PTTS-100102
PTTS-100103
PTTS-100104
PTTS-100105
PTTS-100106
PTTS-100107
PTTS-100108
PTTS-100109
PTTS-100110
PTTS-100111
PTTS-100112
PTTS-100113
PTTS-100114
PTTS-100115

Leak Repairs
Component Replacement
Electrical & Oil Testing
Oil Processing & Recalmation
Inspection Services
LTC Inspections & Overhauls
Retrofit & Life Ext. Services
Re-clamping
Cooling Upgrades
Oil Preservation System
LTC Additions & Modifications

PTTS-200101
PTTS-200102
PTTS-200103
PTTS-200104
PTTS-200105
PTTS-200107
PTTS-200108
PTTS-200109
PTTS-200110
PTTS-200111
PTTS-200112

Risk Assessment
Condition Assessment
Design Assessment
Short Circuit Withstand
Thermal Studies
Electrical Studies
Life Assessment
Feasibility Studies
Thermal Upgrades
LTC Retrofits
Component Replacement
Technical Training
Maintenance
Testing & Diagnostics
LTC Maintenance
Failure Analysis

info@theprescon.com

PTTS-300101
PTTS-300102
PTTS-300103

PTTS-300104
PTTS-300105

PTTS-300106

PTTS-300107

Http://www.theprescon.com

PRESCON SERVICES
TESTING RANGE

SWITCH YARD MANAGEMENT

Prescons presence is to provide


reliable Asset Management Solutions,
which best fit the industrial needs
and to provide best support and
maintenance services.
CIRCUIT BREAKERS
Timing & Motion Analysis

PSBS-100101

CB Contact Resistance

PSBS-100102

Vacuum Integrity Test

PSBS-100103

SF 6 Purity

PSBS-100104

SF 6 Dew Point

PSBS-100105

SF 6 Decomposition

PSBS-100106

SURGE ARRESTORS
Leakage Current Test

PSBS-200101

Watt Loss

PSBS-200102

Megger

PSBS-200103

CT / PT / CCVT
Polarity

PSBS-300101

Excitation Current

PSBS-300102
PSBS-300103
PSBS-300104
PSBS-300105
PSBS-300106

Primary Injection
C & DF
Winding Resistance
Dielectric Strength

info@theprescon.com

Http://www.theprescon.com

PRESCON SERVICES
TESTING RANGE

ROTARY EQUIPMENT MANAGEMENT

Prescons presence is to provide


reliable Asset Management Solutions,
which best fit the industrial needs
and to provide best support and
maintenance services.
STATOR ELECTRICAL & MECHANICAL TESTS

PRET-100101

Partial Discharge Measurement

PRET-100102

RTD Insulation Resistance

PRET-100103

RTD Resistance Measurements

PRET-100104

Transportation Voltage Comparison Test

PRET-100105

Air Gap Baffle Wedge Assembly Tightness

PRET-100106

Check Troque or Trough & Building Blocks

PRET-100107

Visual Inspection of Stator Components

PRET-100108

Wedge Tightness Test (Rotor to be removed)

PRET-100109

Dielectric Absoption/ Polarization Index

PRET-100110

Insulation Resistance of Each Phase

PRET-100111

Thermocouple Continuity Test


Phase Resistance Measurement

PRET-100112
PRET-100113

Doble Test- Power Factor Tip-up

PRET-100114

Loop Test

PRET-100115

ND Test

PRET-100116

ELCID Examination of Generator Stator Core

PRET-100117

(Rotor to be Removed)
Corona Probe Testing

PRET-100118

A.C. / D.C. Hipot

O
T
I
O
N
S

info@theprescon.com

Http://www.theprescon.com

PRESCON SERVICES
Rotary Equipment Management

MAJOR/MINOR OUTAGE MANAGEMENT DATA REVIEW


Generator Rewinding Kit Supply
Root Cause Failure Analysis
Forensic Reports
Failure Model and Effect Studies
Maintenance Staff Training
Supply of Test & Maintenance
Equipment with consultancy

PRET-101101
PRET-101102
PRET-101103
PRET-101104
PRET-101105
PRET-101106
PRET-101107

AVR/ EXCITATION CONTROLS /PSS


AVR Droop Test
AVR Response Test
AVR Tuning
Excitation / AVR Injection Testing
PSS Tuning

PRET-500101
PRET-500102
PRET-500103
PRET-500104
PRET-500105

PRET-600101
PRET-600102
PRET-600103

ONLINE MONITORING
Online Partial Discharge Solutions
Online Vibration Monitoring System

PRET-700101
PRET-700102

INSULATION TESTS
Bearing & Pedestal Insulation Resistance PRET-800101
Rotor Ground Detection Ring
PRET-800102
GCM on Hydrogen Cooled Machines
PRET-800103
PMG TESTS
Winding Resistance
Visual Inspection
Insulation Resistance

Impedance Test
Insulation Resistance of Winding
Rotor Winding Resistance Measurement
Air Test Radial Lead Assemble
Complete Visual Inspection of Gen Rotor
Pole Balance
RSO Test

PRET-200101
PRET-200102
PRET-200103
PRET-200104
PRET-200105
PRET-200106
PRET-200107

EXCITER TESTS

OPERATIONAL DATA REVIEW


Generator Winding Review
Generator Vibration Trends
Cooling System Efficiency

ROTOR ELECTRICAL & MECHANICAL TESTS

PRET-900101
PRET-900102
PRET-900103

EXCITER ELECTRICAL TESTS


RTD Resistance Test
RTD Insulation Resistance
Thermocouple Continuity
EXCITER ROTOR TESTS
Winding Resistance
Visual Inspection
Insulation Resistance

PRET-400101
PRET-400102
PRET-400103
PRET-400104
PRET-400105
PRET-400106

EXCITER STATOR TESTS


A.C Impedance (Pole Balance)
Insulation Resistance
Visual Inspection
Winding Resistance
Field Current Limiting Resistance

PRET-400107
PRET-400108
PRET-400109
PRET-400110
PRET-400111

DIODE WHEEL TESTS


Fuse Testing
Diode Current Leakage
Capacitor Change & Discharge
Diode Wheel Insulation

Insulated Ground Detection Ring Insulation

Diode/Heat Sink Contact Resistance


Diode Forward &Reverse Resistance
Voltage Divider Resistance
Radial Main Leads & Coupling Leads

info@theprescon.com

PRET-300101
PRET-300102
PRET-300103
PRET-300104
PRET-300105
PRET-300106
PRET-300107
PRET-300108
PRET-300109

Http://www.theprescon.com

PRESCON SERVICES
TESTING SERVICES

PLANT MANAGEMENT

Prescons presence is to provide


reliable Asset Management Solutions,
which best fit the industrial needs
and to provide best support and
maintenance services.
FIRST THIRD PARTY/ INDEPENDENT TESTING SERVICES
Backed by DOBLE (USA), ETAP, TWI

ELECTRICAL
Thermography
Power Transformer Testing
Generator Testing
Motor Testing
Relay & Control Panel Testing
Switch Yard & Equipment
Plant Partial Discharge Survey
Residual Life Assessment

PPMS-100101
PPMS-100102
PPMS-100103
PPMS-100104
PPMS-100105
PPMS-100106
PPMS-100107
PPMS-100108

P a k i s t a n s
F i r s t N E TA
Member Company

MECHANICAL
Thermography
Vibration Analysis
Generator Testing
NDT Services
Safety Valves Testing
Exchanger Cleaning Services

PPMS-200101
PPMS-200102
PPMS-200103
PPMS-200104
PPMS-200105
PPMS-200106
info@theprescon.com

Http://www.theprescon.com

PRODUCTS
PROJECT PROCUREMENT

PROCUREMENT

Turnkey soluionts f or
all of your procurement
needs , from round the globe
Our mission is to assist while you install & maintain the Assets of the
plants/industry to increase the reliability in production. In this regard,
the top most OEM companies round the world is approaching the EPC
companies of Pakistan to provide them State-of-the-Art Products
related to Power, I&C, Valves, etc. certainly with our aid and strong
technical back-up after-sales support. Our most of the products can
fulfill the requirements of Oil & Gas sector of Pakistan.

I N S T R U M E N T AT I O N
Prescon offer full range of instrumentation and controls including but not limited to
supply of Pressure transmitters, RTDs, Thermocouples, Thermocouple Extension
wires/cables, Instrumentation Cables, Flow Meters, Primary Elements like
orifice/pitot/venturi/nozzle, Pressure & temperature gauges, Shut-off & Control
Valves, Butterfly/Gate/Globe Manual Valves, Fittings, Seamless Tubing, PLCs, etc.

ELECTRICAL
Prescon can supply Gensets (New and refurbished), Power Transformers, Switchgear,
Industrial Sockets, Cables, Glands,Industrial Communication Systems - Public Address,
Page Party, Telephone Sets ATEX approved, Connecters, Lighting - Explosion Proof,
Termination Kits, Cable Trays, Industrial UPS, Batteries.
In addition to above, Prescon offers Rewenable Energy solutions including Solar
Power Street Lights, Solar Power, Wind Power for all your needs

M E C H A N I C A L / H VA C
Air Compressors, Dryers, Pumps, Steel pipes, HVAC, Chillers, Fin
Fan Coolers, Valves, Couplings, Supply Air Fans,

info@theprescon.com

Http://www.theprescon.com

PRODUCTS
PROJECT PROCUREMENT

I N S T R U M E N T AT I O N
PROJECTS/SERVICES
Pneumatic, Hydraulic,
& Electric Control Panels
Heat Tracing
Pipe & Valve Jacketing
PLC Programming
Purging - X, Y, Z
Steam Systems
TRANSMITTERS & SWITCHES
Conductivity
Distance - Potentiometric
Density
Flow
Level
PH
Pressure
Position/Proximity
Power/Current
Speed
Temperature
Vibration
Viscosity
Voltage
Weight
ELECTRONICS
Alarms
Barriers
Calibrators
Controllers
Indicators
Relays
Recorders
RTD/Thermocouple
Power Supplies
Timers & Counters
Totalizers & Transducers

SELF CONTAINED
Analyzers
Chemical Seals
Conservation Vents
Level Gauges
Orifice Plates
Rotameters
Rupture Discs
Pressure Gauges
Pressure Regulators
Safety Valves
Sight Glasses
Snubbers
Temperature Gauges
Temperature Regulators
Valves - All Types
Valve Accessories
ACCESSORIES
Cables & Trays
Eye Wash / Safety Showers
Stands
Channel Struts
Enclosures - General &
Explosion Proof
Seal Pots
Strainers
Steam Traps
Sun Shades
Tubing
Tube Fittings
Valve Manifolds
CONTROL ROOM HARDWARE
Operator / Process I/O
Control Consoles
Programmable Logic Controllers
Racks
UPS

info@theprescon.com

Http://www.theprescon.com

PRODUCTS
PROJECT PROCUREMENT

ELECTRICAL
Breakers
Cables & Cable Trays/Ties
Conduits
Enclosures
Fittings
Fuses
Lamps
Relays
Safety Switches
Transformers

Industrial UPS
Batteries
Isolators
CT/PTs
Relays
Meters
New and Used Gensets
Wind Turbines - 300 W to 600 KW
Solar Powered Street Lights
Solar Power for Home and Office

M E C H A N I C A L / H VA C
Air Compressors
Blowers
Cabinets & Lockers
Carpet Extractors & Dryers
Cleaning Chemicals
Drain Cleaning Machines
Ducts
Drills & Drill Bits
Fans
Filters
Fire Alarms
Gloves
Hand Trucks
Heaters
Hoses & Hose Fittings
Locks
Pumps
Refrigerants & Recovery Systems
Respirators
Saws & Blades
Pipe Threading Machines/Tools
Tools - Hand & Electric
Vacuum Cleaners
Water Coolers & Heaters
info@theprescon.com

Http://www.theprescon.com

QUALITY POLICY
PRESCON IN PURSUIT OF PERFECTION

PRECISION
IS WHAT WE PROMISE

PRESCON

OUR BELIEF
We can only stay successful if
we meet rather exceed
customers current & future
quality requirement &
expectations
Prescon in Pursuit of Perfection

POLICY:
Accuracy of data we generate for our customers/ clients.
Continuous training courses for our employees to maximize their potential
Continuous improvement/ improvisation
Run a continuous check on all applicable regulations and standards
Commitment to add to TQM program every day and at every level of our
organization
OBJECTIVES:
Standardized, Specified, regularized and quality services as per codes of
practice
Involvement of every employee for potential enhancement
Interaction with customers as partners to discuss quality matters for
improvements
Ensure timely actions taken in dealing with customer related issues
Ensure continuous focus from our organization to have customer
satisfaction as an outcome

info@theprescon.com

Http://www.theprescon.com

You might also like