You are on page 1of 4

application

contruction/finish

A highly efficient, visually comfortable,


architecturally styled recessed LED luminaire
designed with a minimalistic strategy to achieve
sustainable objectives.
Low profile configuration is only 3" high with sloped
sides for a sleek appearance.
Clean, modern design offers a fresh variation on
the popular dual chamber theme and provides
architectural styling compatible with virtually any
area.
Soft opal diffusers with large luminous area
minimize apparent brightness and provide high
visual comfort perfect for a wide variety of general
lighting applications like offices, schools, retail, or
healthcare.
Multiple lumen packages over a wide range to
provide significant application flexibility over light
levels and/or luminaire spacing.
A high lumen package can be used in conjunction
with wide luminaire spacing to reduce luminaire
quantities and overall cost while maintaining good
uniformity.
Directs a controlled amount of light to the higher
angles in the room to balance the brightness of the
surfaces and eliminate cave effect while creating
the impression of a larger, brighter space without
glare.
Excellent color rendering with a CRI of 80.
LEDs are an excellent source for use with controls
since dimming or frequent switching does not
degrade the performance or life of the source.
Integral or external sensors are available for use.
Surface mount design requires no plenum space.

Uncomplicated design is well under 3 in depth and


only requires a few parts outside of the electrical
system and hardware, creating several benefits:
- Less material required
- Less packaging required
- Reduced weight
- Less energy required for construction and
assembly
- More luminaires can be shipped per truck to
reduce fuel use and emissions
Luminaire is painted after fabrication with a matte
white polyester powder coating for a high quality,
durable finish with no unfinished edges to create an
installation hazard or potential for corrosion.

0838-AR
12/03/2012

Architectural
Surface DuaLED
2x4
LED

electrical
Integral sensor options for occupancy sensing and/
or daylight harvesting are available for additional
energy savings with no reduction of life or increase
in installation labor.
Driver and LED boards are easily accessible
from below without tools. Multiple LED boards
are individually replaceable if needed via plug-in
connectors to ensure long service life.
0-10V dimming and emergency options are available
to add even more application flexibility.
Five year luminaire warranty includes LED boards
and driver (emergency driver and batteries have a
three year warranty in models so equipped.)
High efficiency LEDs have a minimum 50,000 hour
rated life (L70.)
ETL listed to UL and CSA standards, suitable for
damp locations.

enclosure

Specifiers Reference
Project
Type
Model No.
Comments

Dual chamber configuration utilizes two diffusers


with large surface area for brightness control.
Opal diffusers provide soft, comfortable lighting
while maintaining high efficiency.
Diffusers require no frames or fasteners and can be
easily removed from below without tools if needed.

Green Choice: 2SDL49L840-4-D-UNV-DAYOCC


2

Lumen Package

Width
2 2'

SDL

Length

43L 4300 nominal delivered lumens


49L 4900 nominal delivered lumens
58L 5800 nominal delivered lumens
73L 7300 nominal delivered lumens

4 4'

Voltage

UNV Universal voltage,


120-277 volt
347

Options

Color

Family
SDL Surface DuaLED

840 80 CRI, 4000K


835 80 CRI, 3500K

Diffusers

D Diffuse (Opal)

CC Custom Color
F1 3/8" Flex, 3 Wire 18 gauge
F2 3/8" Flex, 4 Wire 18 gauge
GLR1 Fusing, Fast Blow
DIM 0-10V dimming driver
OCC Integral sensor, occupancy
DAY Integral sensor, daylighting
DAYOCC Integral sensor, daylighting and occupancy

energy data
Model

Initial Delivered Lumens


at 25C Ambient*

Input Power

Lumens Per Watt*

2SDL43L840-4-D

4,304

46W

94LPW

2SDL43L835-4-D

4,045

46W

88LPW

2SDL49L840-4-D

4,919

55W

89LPW

2SDL49L835-4-D

4,597

55W

84LPW

2SDL58L840-4-D

5,756

61W

94LPW

2SDL58L835-4-D

5,392

61W

88LPW

2SDL73L840-4-D

7,263

80W

91LPW

2SDL73L835-4-D

6,763

79W

86LPW

Fluorescent
Configuration

Approx.Total
Delivered Lumens

DuaLED Equivalent*

Fluorescent
Configuration

Approx.Total
Delivered Lumens

DuaLED Equivalent*

2 lamp F32T8

4,100

2SDL43L8xx-4-D

4 lamp F32T8

7,200

2SDL73L8xx-4-D

2 lamp F28T5

4,600

2SDL49L8xx-4-D

4 lamp F28T5

8,000

n/a, max. lumens would be 2SDL73L8xx -4-D

2 lamp F54T5HO

7,200

2SDL3L8xx-4-D

3 lamp F32T8

6,000

2SDL58L8xx-4-D

3 lamp F28T5

6,300

2SDL58L8xx-4-D

*DuaLED equivalent will provide similar delivered lumens and light levels. Analysis to determine appropriate light levels for the space is highly recommended.

dimensions
50" (1320mm)

25-1/4" (641mm)
3" (76mm)

Integral sensor options are available offering occupancy


sensing, continuous dimming daylight sensing, or
occupancy and daylight sensing together.

0838-AR

12/03/2012

Surface DuaLED 2x4 LED

photometry
2x4 Surface DuaLED, 4300 delivered lumens
Catalog No.

2SDL43L840-4-D

Test No.

30384D1

S/MH

1.3

Lamp Type

45WLED

Lumens/Lamp

4304

Input Watts

46

Comparative yearly lighting energy cost per 1000


lumens $2.55 based on 3000 hrs. and $.08 pwr
KWH.
The photometric results were obtained in the Philips
Day-Brite laboratory which is NVLAP accredited by the
National Institute of Standards and Technology.

LER 94

Candlepower
End

45

Cross

1454
1465
1445
1414
1369
1314
1248
1173
1087
993
888
778
664
554
430
309
194
86

1454
1449
1429
1398
1356
1302
1236
1161
1076
991
895
786
672
556
440
313
190
85

1454
1429
1414
1386
1356
1307
1247
1176
1093
1002
912
797
684
563
432
306
193
87

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85

Photometric values based on test performed in


compliance with LM-79.

2x4 Surface DuaLED, 4900 delivered lumens


Catalog No.

2SDL49L840-4-D

Test No.

30385D1

S/MH

1.3

Lamp Type

53WLED

Lumens/Lamp

4919

Input Watts

55

Comparative yearly lighting energy cost per 1000


lumens $2.70 based on 3000 hrs. and $.08 pwr
KWH.
The photometric results were obtained in the Philips
Day-Brite laboratory which is NVLAP accredited by the
National Institute of Standards and Technology.

End

45

Cross

1662
1671
1650
1615
1565
1499
1425
1337
1237
1131
1013
887
756
616
491
349
221
99

1662
1656
1632
1599
1549
1487
1414
1326
1231
1130
1033
903
770
633
499
354
216
98

1662
1636
1622
1591
1555
1497
1429
1346
1253
1151
1037
914
787
645
496
349
221
99

2x4 Surface DuaLED, 5800 delivered lumens


2SDL58L840-4-D

Test No.

30372D1

S/MH

1.3

Lamp Type

30WLED

Lumens/Lamp

5756

Input Watts

61

Comparative yearly lighting energy cost per 1000


lumens $2.55 based on 3000 hrs. and $.08 pwr
KWH.
The photometric results were obtained in the Philips
Day-Brite laboratory which is NVLAP accredited by the
National Institute of Standards and Technology.
Photometric values based on test performed in
compliance with LM-79.

Surface DuaLED 2x4 LED

Lumens
1134
1863
3330
4302

% Luminaire
26.4
43.3
77.4
100.0

Angle
45
55
65
75
85

End
1889
1825
1764
1606
1328

45
1886
1844
1770
1627
1312

Cross
1907
1870
1792
1591
1343

Coefficients of Utilization
EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20)
pcc
80
70
50
pw
70
50
30
70
50
30
50
30
RCR
0
118 118 118
115 115 115
111 111
1
108 103 98
106 101 96
96
93
2
97
90
82
95
88
81
83
79
3
89
79
69
86
77
68
73
67
4
81
69
60
79
68
59
66
57
5
75
61
53
72
60
52
58
51
6
68
56
46
67
55
46
53
45
7
64
50
41
61
50
40
47
40
8
59
46
36
57
45
36
44
36
9
56
41
34
54
41
34
40
33
10
52
39
30
51
38
30
36
29

Degrees
0-30
0-40
0-60
0-90

Lumens
1296
2129
3807
4917

Average Luminance
% Luminaire
26.4
43.3
77.4
100.0

Angle
45
55
65
75
85

End
2152
2081
1961
1814
1528

45
2150
2118
2015
1840
1513

Cross
2190
2144
2053
1814
1528

Coefficients of Utilization
EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20)
pcc
80
70
50
pw
70
50
30
70
50
30
50
30
RCR
0
118 118 118
115 115 115
111 111
1
108 103 98
106 101 96
96
93
2
97
90
82
95
88
81
83
79
3
89
79
69
86
77
68
73
67
4
81
69
60
79
68
59
66
57
5
75
61
53
72
60
52
58
51
6
68
56
46
67
55
46
53
45
7
64
50
41
61
50
40
47
40
8
59
46
36
57
45
36
44
36
9
56
41
34
54
41
34
40
33
10
52
39
30
51
38
30
36
29

LER 94

End
1951
1963
1937
1895
1835
1761
1675
1572
1453
1326
1191
1044
882
724
573
409
258
111

Average Luminance

Light Distribution

Candlepower
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85

Degrees
0-30
0-40
0-60
0-90

Light Distribution

Angle

Photometric values based on test performed in


compliance with LM-79.

Catalog No.

LER 89

Candlepower
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85

Average Luminance

Light Distribution

Angle

45
1951
1943
1919
1879
1821
1747
1658
1557
1444
1324
1191
1042
886
746
589
418
253
108

Cross
1951
1922
1905
1865
1827
1759
1677
1580
1469
1347
1210
1069
919
758
580
406
252
110

Degrees
0-30
0-40
0-60
0-90

Lumens
1522
2499
4462
5755

% Luminaire
26.4
43.4
77.5
100.0

Angle
45
55
65
75
85

End
2523
2449
2305
2126
1714

45
2519
2444
2375
2173
1667

Cross
2563
2508
2413
2111
1698

Coefficients of Utilization
EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20)
pcc
80
70
50
pw
70
50
30
70
50
30
50
30
RCR
0
118 118 118
115 115 115
111 111
1
108 103 98
106 101 96
96
93
2
97
90
82
95
88
81
83
79
3
89
79
69
86
77
68
73
67
4
81
69
60
79
68
59
66
57
5
75
61
53
72
60
52
58
51
6
68
56
46
67
55
46
53
45
7
64
51
41
63
50
40
47
40
8
59
46
36
57
45
36
44
36
9
56
41
34
54
41
34
40
33
10
52
39
30
51
38
30
36
29

12/03/2012

0838-AR

0838-AR

Surface DuaLED 2X4 LED

12/03/2012

photometry
2x4 Surface DuaLED, 7300 delivered lumens
Catalog No.

2SDL73L840-4-D

Test No.

30371D1

S/MH

1.3

Lamp Type

38WLED

Lumens/Lamp

7263

Input Watts

80

Comparative yearly lighting energy cost per 1000


lumens $2.64 based on 3000 hrs. and $.08 pwr
KWH.
The photometric results were obtained in the Philips
Day-Brite laboratory which is NVLAP accredited by the
National Institute of Standards and Technology.

LER 91

Candlepower
End

45

Cross

2460
2464
2433
2380
2306
2216
2101
1975
1825
1667
1505
1312
1122
918
730
521
322
145

2460
2448
2417
2364
2294
2200
2090
1963
1819
1670
1497
1314
1121
941
744
523
317
137

2460
2428
2402
2354
2306
2217
2117
1991
1852
1697
1532
1352
1161
952
733
515
313
135

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85

Average Luminance

Light Distribution

Angle

Photometric values based on test performed in


compliance with LM-79.

Degrees
0-30
0-40
0-60
0-90

Lumens
1917
3149
5630
7264

% Luminaire
26.4
43.4
77.5
100.0

Angle
45
55
65
75
85

End
3172
3078
2923
2708
2238

45
3178
3082
2996
2719
2115

Cross
3229
3172
3031
2677
2084

Coefficients of Utilization
EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20)
pcc
80
70
50
pw
70
50
30
70
50
30
50
30
RCR
0
118 118 118
115 115 115
111 111
1
108 103 98
106 101 96
96
93
2
97
90
82
95
88
81
83
79
3
89
79
69
86
77
68
73
67
4
81
69
60
79
68
59
66
57
5
75
61
53
72
60
52
58
51
6
68
56
46
67
55
46
53
45
7
64
51
41
61
50
40
47
40
8
59
46
36
57
45
36
44
36
9
56
41
34
54
41
34
40
33
10
52
39
30
51
38
30
36
29

sample applications
Spacing

Number of
Luminaires

Model

8'x8'

15

2SDL43L840-4-D
2SDL49L840-4-D

Maintained
Average
Illumination

Max./Min.

Input
Power
per lum.

Watts/
Sq. foot

47.3 fc

2.6

46W

0.68

54.1 fc

2.6

55W

0.82

Open Area

8'x10'

10'x10'

10'x12'

15

12

12

Open Area:

2SDL58L840-4-D

63.4 fc

2.7

61W

0.91

2SDL73L840-4-D

79.9 fc

3.6

80W

1.19

2SDL43L840-4-D

38.2 fc

2.9

46W

0.55

2SDL49L840-4-D

43.6 fc

2.9

55W

0.66

2SDL58L840-4-D

51.1 fc

2.9

61W

0.73

2SDL73L840-4-D

64.5 fc

2.9

80W

0.95

2SDL43L840-4-D

35.9 fc

2.3

46W

0.55

2SDL49L840-4-D

41.0 fc

2.3

55W

0.66

2SDL58L840-4-D

48.0 fc

2.3

61W

0.73

2SDL73L840-4-D

60.6 fc

2.3

80W

0.95

2SDL43L840-4-D

34.9 fc

1.7

46W

0.55

2SDL49L840-4-D

39.0 fc

1.7

55W

0.66

2SDL58L840-4-D

45.6 fc

1.7

61W

0.73

2SDL73L840-4-D

57.5 fc

1.7

80W

0.95

2012 Philips Day-Brite


All rights reserved.
776 South Green Street Tupelo, MS 38804
p. 800.234.1890 f. 662.841.5501 www.daybrite.com
Canadian Division
189 Bullock Drive Markham, Ontario L3P 1W4
p. 905.294.9570 f. 905.294.9811

The controlled high angle lighting distribution of


DuaLED provides diffuse uniform lighting in large
spaces and creates significant vertical illumination.
Wide luminaire spacing is possible.
A sample area:
42' long x 24' wide x 9' ceiling
80/50/20 reflectances
Calculation grid at 2.5'
Maintenance factors 0.85 LLD, 0.94 LDD, 0.799 LLF
Uniformity is excellent at 3.0 or less, even when
moving to extended 10'x12' luminaire spacing.
High delivered lumen options allow the extended
spacing to provide IES recommended illumination
levels for many tasks. Smooth, uniform lighting
at recommended light levels with good vertical
illumination is available with power density between
0.5 and 0.75 Watts per square foot, satisfying any
known energy codes.

Contact Factory for Additional Configurations.


Specifications are subject to change without notice.
Consult website for latest version of this spec sheet.

You might also like