Professional Documents
Culture Documents
Ama-Drainer 301
Ama-Drainer 303
Fields of Application
Design / Variants
Medium Handled
Bearings
Operating Data
Q
H
t
1)
Shaft Seals
Ama-Drainer
Impeller end
Motor end
301/303
2 shaft seal rings
1 shaft seal ring
An oil chamber is fitted in-between the two seals.
Drive
up to 3 minutes for waste water from wash at the boil of washing machines and dish-washers for non-industrial use.
Designation
Vertical, fully floodable submersible motor pumps in closecoupled design, IP 68, single-stage, with integrated swing
check valve.
Pump control via float switch.
External control is possible with 10 m motor cable.
Max. immersion depth 2 m.
301 .1
Type series
Code number
Index
S = with float switch
N = without float switch
E = single-phase a.c. motor
C = plastic version with
chrome nickel molybdenum steel internals
E/C
Materials
Ama-Drainer
Standard design
Variant C
Pump casing
Volute casing/
suction cover
Foot
Motor housing
Polypropylene
Polyphenylene oxide
Polypropylene
Polyphenylene oxide
Polypropylene
Chrome nickel steel (1.4301)
Shaft
Chrome steel
Impeller
Polypropylene (301.1)
Polyphenylene oxide (303.1)
Polyacetal
Polypropylene
Polypropylene
Chrome nickel molybdenum steel
(1.4571)
Chrome nickel molybdenum steel
(1.4571)
Polypropylene (301.1)
Polyphenylene oxide (303.1)
Polyacetal
Polypropylene
Casing cover
Float switch (float)
*) in standard design
Ama-Drainer
Ama-Drainer 301, 303
n = 2800 1/min
ISO 7/I
Rp
Particle
size
P1
P2
50 Hz
mm
kW
kW
1~230 V
A
max.
Ident. No.
mm2
net
kg
301.1 SE
301.1 SE/NE 2)
1 1/4
10
0.3
0.15
1.4
03*)
10
3.9
5.0
303.1 SE
303.1 SE/NE 2)
1 1/4
10
0.8
0.4
3.6
03*)
10
5.6
6.6
1 1/4
10
0.3
0.15
1.4
10
3 x 1.0
40 981 774
5.0
2)
1/
4
10
0.8
0.4
3.6
10
3 x 1.0
40 981 793
6.6
1)
Ama-Drainer
Chemical Resistance Chart
Ama-Drainer
Medium handled
Standard
design
Medium handled
Variant C
Ama-Drainer
Standard
design
Antifreeze
Trisodium phosphate
Antifrogen-water mixture
Uric acid
Beer
Vaseline
Butter milk
Vinegar
Calcium acetate
Calcium hydroxide
Whey
Castor oil
Cider
Coconut oil
Water:
Condensed milk
Boiler water
Corn oil
Condensate
Deionized water
Cooling water
Edible oil
Drainage water
Fire-extinguishing water
Edible vinegar
Variant C
Ethylene glycol
Glycerine
Heating water
Glycol
Lime water
Grisironr
Lemonades
Pure water
Liquid fertilizer
Raw water
Milk
Salt water
Peanut oil
Sea water
Polyglycol
Potassium carbonate
Potassium hydroxide
Rape oil
x
x
x
Silicon oil
Sodium carbonate
Sodium chloride up to
3 % concentration
Sodium nitrate
Sodium perborate
Sodium sulphate
Soy-bean oil
Spirits
Ama-Drainer
Product Features
Ama-Drainer 303 SE
Broad range of submersible
motor pumps
Your benefit:
D Optimum adjustment to the
actual requirements taking into
account economic aspects
D Design is matched to the
medium pumped (for waste
water or aggressive water)
Optimised hydraulic
systems and motors
Your benefit:
D Large pump output at high
efficiency
D Economic operation
Ama-Drainer
Ama-Drainer 301 SE
Ama-Drainer 303 SE
autom.
manually
autom.
manually
1)
E5
P13
E 12
P11
P 18
P 18
E 14/2
E 14
P
P
P
E
E
E
E
E
E
R
11
13
18
5
5/2
12
14
14/2
14/3
Gate valve
Y-pipe
Cover plate
Alarm switchgear AS 5
Horn
Switchgear
Float switch, normal water level
Float switch, high water level
Alarm contactor
Backwash level
E 14/3
mm
Ama-Drainer
D1
D2
301
275
320
1060 (x 500)
400
303
275
320
1060 (x 500)
500
Ama-Drainer
Pump Accessories
Rp 1 1/4 / Rp 1 1/4
P 11
Rp 1 1/4 / Rp 1 1/4
P 13
P 18
303.1
P 10
301.1
Ama-Drainer
kg
01 009 771
0.90
0
01 014 219
0.50
R 1 1/4
18 040 311
4.30
0
R 1 1/4
P 21
R 1 1/4
18 079 719
1.70
P 24
C-G 1 1/2
01 002 463
0.30
P 26
DIN 14 321
C 52
(X)
(X)
00 524 551
0.30
P 28
DN 40 plastic hose
with built-in C couplings
DIN 14 811
C 52 05 m
C 52 10 m
C 52 20 m
X
X
X
X
X
X
01 062 592
01 062 593
01 062 594
1.70
2.80
5.00
DN 50 plastic hose
with built-in C couplings
DIN 14 811
C 52 05 m
C 52 10 m
C 52 20 m
(X)
(X)
(X)
(X)
(X)
(X)
00 522 262
00 522 263
00 522 264
2.30
4.20
5.70
00 106 756
0.20
11 035 587
0.20
P 31
P 32
Ama-Drainer
Electrical Accessories
Alarm switchgear AS 0,
mains-dependent,
with circuit-breaker, with piezoceramic
signal transmitter, 85 dB(A) at a distance
of 1 m and 4.1 kHz.
303.1
E2
301.1
Ama-Drainer
230 V~/
12 V =
1.2 VA
29 128 400
0.5
230 V~/
12 V =
1.2 VA
29 128 440
1.2
230 V~/
12 V =
5 VA
00 530 561
1.7
00 534 211
0.25
19 070 135
19 070 137
1.0
1.0
29 128 420
0.5
19 070 212
0.9
kg
Alarm switchgear AS 4,
mains-independent,
with circuit-breaker, with piezoceramic
signal transmitter, 85 dB(A) at a distance
of 1 m and 4.1 kHz, green equipment-on lamp,
volt-free contact for hook-up to a control room,
with self-charging power supply unit for 5 hours operation
in case of a mains failure.
Plastic housing IP 20,
140 x 80 x 57 mm
Use float switch (item E 14) or humidity sensor F 1 (item E 8)
as contactor.
E5
Alarm switchgear AS 5,
mains-independent,
with self-charging power supply unit
for 10 hours operation in case of a mains failure,
mains pilot LED, fault indicator lamp,
horn-off push button, volt-free contact for
hook-up to a control room, ready to be plugged in,
with 1.8 m cable and plug.
ISO housing IP 41,
190 x 165 x 75 mm
Use float switch (item E 14) as contactor.
E 5/2
Internal horn,
type of enclosure IP 32
12 V = 92 dB(A), 1.2 W
E 61)
E7
Alarm switchgear AS 2,
mains-dependent,
with circuit-breaker, with piezoceramic
signal transmitter, 85 dB(A) at a distance
of 1 m and 4.1 kHz, green equipment-on lamp,
volt-free contact for hook-up to a control room.
1)
Designed for 1 ~ 230 V. In case of other voltages and frequencies please contact KSB.
Ama-Drainer
Electrical Accessories
301.1
303.1
Ama-Drainer
E9
Alarm switchgear AS 1,
230 V~/
in ISO plug housing, IP 30,
9V=
mains-independent, with self-charging power supply
1.5 VA
unit for 5 hours operation in case of a mains failure,
acoustic signal 70 dB(A) with circuit-breaker and
add-on signal transmitter with 3 m connection cable, max. 60 C,
not suitable for steam and condensate;
2 possible applications for alarm transmission:
1. High-water alarm by suspending the humidity sensor into a
(pump) pit above the start-up level of the pump.
2. Water alarm signal at a water level of only 1 mm (!) by placing
the contactor on the floor in the danger zone of the cellar or
next to the washing machine in kitchen or bathroom.
00 533 740
0.9
E 111)2)
19 070 187
2.0
19 070 151
9.3
03 m
05 m
10 m
15 m
20 m
25 m
30 m
X
X
X
X
X
X
X
X
X
X
X
X
X
X
11 037 742
11 037 743
11 037 744
11 037 745
11 037 746
11 037 747
11 037 748
0.5
0.8
1.4
1.8
2.6
2.9
3.4
05 m
10 m
20 m
X
X
X
X
X
X
11 037 756
11 037 757
11 037 758
0.8
1.4
2.6
with shockproof
230 V AC
50 Hz
adapter plug 2)
(NO contact)
max. 8 A
Circuit closed when
switch floats on top (H 07 RN-F3G1)
03 m
05 m
10 m
20 m
X
X
X
X
X
X
X
X
11 037 749
11 037 750
11 037 751
11 037 752
0.6
0.9
1.5
2.7
with shockproof
adapter plug 2)
(NC contact)
Circuit open when
switch floats on top (H 07 RN-F3G1)
03 m
05 m
10 m
20 m
X
X
X
X
X
X
X
X
11 037 759
11 037 760
11 037 761
11 037 762
0.6
0.9
1.5
2.7
00 534 217
0.4
kg
E 15
1)
2)
Designed for 1 ~ 230 V. In case of other voltages and frequencies please contact KSB.
Required only if volt-free signals have to be transmitted to the control room.
230 V~/
10 A
2331.151-10 / 1.5.2002
E 14