You are on page 1of 4

TESTING & EVALUATION CAPABILITIES

LAMPS & LUMINAIRE LABORATORY

Electrical Research & Development Association


(Accredited by NABL, Govt. of India)
Vadodara Laboratory - Head Office
ERDA Road, GIDC, Makarpura,
Vadodara 390 010, India
Tel. +91(0265) 2642942, 2642964, 2642377,
3043128-3043131, Fax: +91 (0265) 2638382, 2644923
E-mail:nitin.patel@erda.org, mukesh.shah@erda.org;
erda@erda.org ; Web: http://www.erda.org

Mumbai Office
Brabourne Stadium,
87, Veer Nariman Road,
Mumbai 400 020,
Telefax: (022) 22820622, 22815376, Email:
berda@bom8.vsnl.net.in

Mumbai Lab

Delhi Office

Sonepat Site

Rajahmundry Site

Savli Laboratory

R- 336, TTC Industrial


Area, Near Rabale Rly.
Station
Navi Mumbai 400 701

F-28, Pankaj Central


Market, Local Shopping
Complex, IP Extension,
Patparganj Area,
Delhi 110 092
Telefax: (011) 42175634,
Email:erdadel@erda.org

Delhi Road
Sonepat 131 001,
Haryana
Telefax. 0130-2236302
Email: erdaspt@erda.org

Plot No.5;
House No. 78/13/5, SBI
Colony, Shyamala Nagar
Rajahmundry - 533 103
Ph: 0883-2421431
E-mail : erdarjm@erda.org

K-V2/A, GIDC,
Savli, Manjusar,
Dist. Vadodara
Phone:02667 264347/49,
Fax. 02667 264348
E-mail: erdasvl@erda.org

O
V
E
R
T
H
R
E
E
D
E
C
A
D
E
S
O
F
S
E
R
V
I
C
E
T
O
I
N
D
U
S
T
R
Y
A
N
D
U
T
I
L
I
T
I
E
S

Lighting, an integral part of our lives, is broadly categorized as for homes, public places, streets, automobiles, signals,
industrial and airports. A variety of lamps available in the market have made this possible. ERDA is involved in the type
testing of lamps - GLS, Fluorescent, HPMV, HPSV, CFL and LED based lamp and related products like ballasts,
luminaires and starters for over two decades. The test facilities are accredited by the National Accreditation Board for
Testing & Calibration Laboratories (NABL), Govt. of India and Bureau of Indian Standards (BIS). ERDA is also involved
in the development of some of these products.

Testing Capabilities
Sr.
No.

Standard Title/Product

IS Specification

IEC Standard

1.

GLS lamps ( Tungsten Filament lamps)

IS:15518-2004

IEC:60064-2005

(Safety specification)

(Safety specification)

IS:418-2004

IEC:60432-1-2005

(Performance specification)

(Performance specification)

IS:2418-Pt.-1-1977

IEC:61195-1999

3.

GLS lamps (Tungsten Filament lamps)

Tubular fluorescent lamps/


(Double capped fluorescent lamps )

(Safety specification)
IEC:60081-2002
(Performance requirement)

4.

High

Pressure sodium vapour lamps

IS:9974-Pt-1-1981

IEC:62035-2003
(Safety specification)
IEC:60662-2002
(Performance specification)

Self ballasted lamps for General lighting service

IS:15111

Pt.1

2002

IEC:60968-1999
(Safety specification)

Self ballasted lamps for general lighting service

IS:15111 Pt.1-2002

IEC:60969-2001
(Performance specification)

Single capped fluorescent lamps

IEC:60901-2001
(Performance requirement)

Single capped fluorescent lamps

IS:15687-Pt.1-2006

IEC:61199-1999
(Safety specification)

Ballast for tubular fluorescent lamps

IS:1534-1988

IEC:61347-2-8-2004
(Safety specification)
IEC:60921-2004
(Performance specification)

10

Ballast for HPMV lamps

11

Ballast for discharge lamps excluding fluorescent


lamps)

Ballast discharge lamps excluding fluorescent


lamps.

12

13

IS:6616-1981

IEC:61347-2-9-2004
(Safety specification)
IEC:60923-2005
(Performance specification)

AC supplied electronic ballast for tubular


fluorescent lamps.

IS:13021 Pt.1-1991

IEC:61347-2-3-2004

14

AC supplied electronic ballast for tubular


fluorescent lamps.

IS:13021 Pt.21991

IEC:60929- 2006 (Performance


specification)

15

Glow starter for fluorescent lamps

IS:2215-2006

IEC:60155-1993

16

Specification for fixed general purpose


luminaires

IS:10322-Pt.5-sec-1-1985

IEC:60598-2-1-1989

17

Recessed luminaire

IS:10322-Pt.5-sec-2-1985

IEC:60598-2-2-1996

(Safety specification)

?
Underwriters Laboratories (UL) for Certification Testing of Lamps, USA
?
TV SUD South Asia
?
Bureau of Indian Standards (BIS)
?
Bureau of Energy Efficiency (BEE)
?
Vadodara Mahanagar Seva Sadan (VMSS)
?
Thane Municipal Corporation (TMC)
?
Surat Municipal Corporation (SMC)
?
Commissioner of Electricity, Govt. of Gujarat for Household Electrical Appliances
?
Charity Commissioner, Govt. of Maharashtra
?
Gujarat Energy Development Agency (GEDA), Maharashtra Energy Development Agency (MEDA), Commissioner of
Electricity, Gujarat, Energy Management Centre (EMC), Kerala, Chhatisgarh Renewable Energy Development
Agency (CREDA), in their respective jurisdictions for Energy Audit
?
Comparative evaluation carried out for Consumer organization like CERC & VOICE.
?
Users like DGS&D, CPWD, VMSS, TMC, SMC, AMC, BMC, BEST etc.

T
h
e
f
o
l
l
o
w
i
n
g
p
a
r
a
m
e
t
e
r
s
c
a
n
b
e
m
e
a
s
u
r
e
d
u
s
i
n
g
G
o
n
i
o
p
h
o
t
o
m
e
t
e
r
w
i
t
h
L
U
M
B
A
S
E
s
o
f
t
w
a
r
e
:

You might also like