Professional Documents
Culture Documents
CONTROLLERS,
TIMERS, COUNTERS
& HOUR METERS
edge of
cutting trol
he on
A t t urrent c
c
INDEX
1 Leganza
Digital Controllers, 1
8 2 1
C1 C2 I1 I3 I5 ANI1
DEL ALT
Z4
4
6
Z1 Z2 Z3
ESC OK
Q1 Q2 Q3 Q4
Q1 Q2 Q3 Q4
FEATURES 5
1
Digital Controllers,
Leganza
SPECIFICATIONS
SCHEMATIC CONNECTIONS
UP TO 3
EXTENSION MODULE
INPUTS
ADDITIONAL
110 - 240 INPUTS
VAC
PC
Memory
Card LEGANZA
OUTPUTS 8GDDT3 ADDITIONAL CD
OR OUTPUTS
Serial
Interface
Cable
8GDDT2
TO
SERIAL
PORT
All dimensions in mm
2
Digital Controllers,
Leganza
DIMENSIONS
14.3
DIN RAIL
(35 mm-SYMMETRICAL)
DEL ALT
100.0 C/C
107.0
Z4
90.0
45.0
Z2
Z1 Z3
ESC OK
36.0 Ø4.2
65.0
72.0
Leganza
14.3
DIN RAIL
(35 mm-SYMMETRICAL)
100.0 C/C
45.0
Q5 Q6 Q7 Q8
36.0 Ø4.2
72.0 65.0
Extension Module
All dimensions in mm
3
Digital Timers, Eliro
FRONT DISPLAY
RUN TIME
SET ADJ
LED INDICATION
FOR
RELAY STATUS
FEATURES
• 8 mode multifunction facility for complete flexibility • Easy front settings.
and wide range applications. • Tamper-proof with key lock function.
• Timing from 0.1 second to 999 hours.
• Confirms to IEC standards for EMI / EMC, with
• Selectable up/down counting modes to show
mark.
elapsed/remaining time.
• Compact and standard size of 1 module space.
• 3 digit LC display for preset time and run time.
• Optional base or DIN 35 Rail mounting.
• Wide operating range for supply voltage.
SPECIFICATIONS FUNCTIONS
4
Digital Timers, Eliro
STANDARDS AND CERTIFICATION
Certification
Environmental CE
Temperature Limits Operating -10° to +50°C
Storage -20° to +65°C
Humidity 93% Rh
Installation Category II IEC1010 - 1 1990 + 2nd Amendment 1995
Pollution Degree II IEC1010 - 1 1990 + 2nd Amendment 1995
Degree of Protection IP 30 IEC Pub 947 - 1(1998) / IS 13947 Part I 1993
Electromagnetic Compatibility (EMC)
• Vibration F = 10 to 55 Hz, A = 0.35mm or 5gm IS 9000 (Part VIII-1981); IS 9001 (Part XIII-1981)
• Electrostatic Discharge Level III (Air 8KV / Contact 6KV) IEC 1000 - 4 - 2, First Edition 1995 - 01
• Fast Transients Level III 2KV (Peak) Tr / Th = 5 / 50 Rep. Freq. = 5KHz IEC 1000 - 4 - 4, First Edition 1995 - 01
• Surges Level IV Tr / Th = 8/20µs Common Mode : 4KV IEC 1000 - 4 - 5, First Edition 1995 - 02
Differential Mode : 2KV
• Voltage Dips 30% reduction / 10 ms, 60% reduction / 100 ms IEC 1000 - 4 - 11, First Edition 1994 - 06
• Voltage Interruption >95% reduction / 5000 ms IEC 1000 - 4 - 11, First Edition 1994 - 06
Immunity (EMC)
Port - Enclosure 80 - 1000 MHz 10V / m (unmodulated rms) EN 50082 - 2 : 1995
80%AM (1KHz)
Port - AC Mains 0.15MHz - 80MHz 10 V/m (unmodulated ms) EN 50082 - 2 : 1995
80%AM (1KHz)
Radiated (EMC)
Port - Enclosure 30MHz - 230 MHz 30 dBµ V/m Quasi Peak EN 50081 - 2 : 1994
Measured at 30 m distance
230MHz - 1000 MHz 37 dBµ V/m Quasi Peak
Measured at 30 m distance
Conducted Emission
Port - AC Mains 0.15MHz - 0.5MHz 79 dBµ V Quasi Peak, 66 dBµ V Average EN 50081 - 2 : 1994
0.50MHz - 30MHz 73 dBµ V Quasi Peak, 60 dBµ V Average
DIMENSIONS
89.0
67.0
45.0
5
Digital Timer Cum Counter,
Excello
FRONT DISPLAY
1
TIMER / COUNTER
6
2
7
3
8 LOCK
H: M: S 1 2 4
9 LOCK/SET 5
10
RESET
FEATURES
• 48×48 mm format front. TIMER COUNTER
• Option of configurating as either Timer or Counter. 1 Elapsed time Current count
• Easy to read LC display.
2 Set time Preset value
• Simple operation.
3 Output status Output status
• Option of screw terminals for wires/lugs or 11 Pin
socket mouting termination. 4 Up/Down counting --
• Panel mounting 5 Change set time Change Preset value
RANGE 6 Operating mode 1 or 2 Setting
display indication
Cat No. Supply Voltage Termination 7 LOCK indication LOCK indication
42DFT0 240V AC 50/60 Hz Screw Terminals
8 Range indication --
42DFS0 240V AC 50/60 Hz 11 PIN Socket
41DFT0 110V AC 50/60 Hz Screw Terminals 9 LOCK/SET Key LOCK/SET Key
41DFS0 110V AC 50/60 Hz 11 PIN Socket 10 RESET Key RESET Key
45DFT0 24V AC / DC Screw Terminals
45DFS0 24V AC / DC 11 PIN Socket
6
Digital Timer Cum Counter,
Excello
TIMER OPERATION MODES
T t T
P : A1- A2
On Delay
S : B1
(A)
T
R : 15-18
T T t T T T t
A1- A2
P :
Cyclic OFF/ON B1
S :
(b) T OFF T ON T OFF T ON
R :
15 18
A1- A2 T T t T T T t
P :
Cyclic ON/OFF B1
S :
(C) T ON T OFF T ON T OFF
R : 15-18
T T T t T t
P : A1- A2
Signal ON/OFF B1
S :
(d) T T T T
R : 15-18
T t t T t
P : A1- A2
Signal OFF Delay
S : B1
(E) T
R : 15-18
T T t t T
P : A1- A2
Interval
S : B1
(F) T
R : 15-18
T T t T T t T t
P : A1- A2
Signal OFF/ON
S : B1
(G) T T T
T
R : 15-18
T T t t T
P : A1- A2
One Shot
S : B1
(H)
T 1 SEC.
R : 15-18
7
Digital Timer Cum Counter,
Excello
(2) After the counter has been reset. Setting 2 is displayed in the count-down mode. “Ø” appears instead in all
other modes.
Input mode Operation Minimum Input signal width 30 Hz
IN1 or IN2 works as an input * Example where IN1 is the count input an IN2 is the input block (gate).
block (gate) for the other input.
H
IN1 L A A A A
Blocked
H
Addition IN2 L
Counting (addition) 0 1 2 3 ----- n-3 n-2 n-1 n
UP
Counting (subtraction) n n-1 n-2 n-3 ----- 3 2 1 0
Reset Count Up
IN1 or IN2 works as an input * Example where IN2 is the count input an IN1 is the input block (gate).
block (gate) for the other input. Blocked Blocked
H
IN1 L
A A A A
Subtraction H
IN2 L
DOWN
Counting (addition) 0 1 2 3 4 ----- n-1 n
Reset Count Up
Reset
H
IN2 L
Independent
Counting 0 1 2 3 4 3 2 1 2 1 2 3
IND
Reset
Reset
2. Output mode
For the set value 1, you can choose one of the For the set value 2, you can choose one of the
following four modes. following eight modes.
* Maintain output/over count I HOLD-B * Maintain output/hold count HOLD-A
* Maintain output/over count II HOLD-C * Maintain output/over count I HOLD-B
* Maintain output/over count III HOLD-D * Maintain output/over count II HOLD-C
8
Digital Timer Cum Counter,
Excello
* One shot/over count SHOT-A * Maintain output/over count III HOLD-D
* Phase PHASE * One shot/over count SHOT-A
* One shot/recount I SHOT-B
* One shot/recount II SHOT-C
* One shot/hold count SHOT-D
* Output mode for set value 1
Output mode Operation * (Example when input mode is either addition or subtraction)
Output control is maintained after Counting (addition) n-2 n-1 n n+1 n+2
count-up completion and until
Maintain output resetting However, counting is Counting (subtraction) n+2 n+1 n n-1 n-2
Able
Over count I possible despite completion of Counting able/unable
ON
count-up OFF
HOLD-B Output Control 1
* n : Set value 1
Output control is maintained after n-2 n-1 n n+1 n+2
Counting (addition)
count-up completion and until the
Maintain output next signal enters. However, Counting (subtraction) n+2 n+1 n n-1 n-2
Able
Over count II counting is possible despite Counting able/unable
ON
completion of count-up Output Control 1 OFF OFF
HOLD-C
* n : Set value 1
If the count value is greater than or Counting (addition) n-2 n-1 n n+1 n+2
equal to the preset value when
Counting (subtraction) n+2 n+1 n n-1 n-2
Maintain output counting up, the control is held. The Able
Counting able/unable
Over count III count operation is possible anyway. ON
OFF
HOLD-C Output Control 1
(addition)
ON
Output Control 2 OFF
(subtraction)
* n : Set value 1
Output control is maintained after Counting (addition) n-2 n-1 n n+1 n+2
count-up completion for a fixed time
Counting (subtraction) n+2 n+1 n n-1 n-2
One shot (approx. 1 sec.) Counting is possible
Able
Over count despite completion of count-up. Counting able/unable
ON
SHOT-A Output Control 1
OFF OFF
Approx 1s
* n : Set value 1
Output mode Operation * (Example when input mode is either addition or subtraction)
Output control is maintained after
Counting (addition) n-3 n-2 n-1 n
count-up completion and until
Maintain output resetting During that time, the count Counting (subtraction) 3 2 1 0
Able Unable
Over count display does not change from that Counting able/unable
at count-up completion. ON
HOLD-A OFF
Output Control 2
* n : Set value 2
Output control is maintained after Counting (addition) n-2 n-1 n n+1 n+2
count-up completion and until
Maintain output resetting However, counting is Counting (subtraction) 2 1 0 -1 -2
Counting able/unable Able
Over count I possible despite completion of ON
count-up Output Control 2 OFF
HOLD-B
* n : Set value 2
9
Digital Timer Cum Counter,
Excello
Output mode Operation * (Example when input mode is either addition or subtraction)
Output control is maintained after Counting (addition) n-2 n-1 n n+1 n+2
count-up completion and until the
Maintain output next signal enters. However, Counting (subtraction) 2 1 0 -1 -2
Able
Over count II counting is possible despite Counting able/unable
ON
completion of count-up Output Control 2 OFF OFF
HOLD-C
* n : Set value 2
If the count value is greater than or Counting (addition) n-2 n-1 n n+1 n+2
equal to the present value when Counting (subtraction) 2 1 0 -1 -2
Maintain output counting up the counter starts Counting able/unable Able
Over count III counting up again. the count ON
Output Control 2 OFF
operation is possible anyway. (addition)
HOLD-D ON
Output Control 2 OFF
(subtraction)
* n : Set value 2
* n : Set value 2
Output control is maintained after Counting (addition) n-2 n-1 n n+1 n+2
* n : Set value 2
10
Digital Timer Cum Counter,
Excello
Output mode for set value 1
HOLD-C HOLD-D HOLD-B SHOT-A
As usual As usual
SHOT-A
(this combination unchanged) (this combination unchanged)
Approx.1s
Output 1 Output 1
Output 1
Output mode SHOT-B
Output 2 Output 2
for set value 2
Approx.1s Output 2 Approx.1s
SHOT-C
SHOT-D
Note : When control output 1 is on, the output mode of setting 2 (SHOT - A, B, C, D) is also on and output 1 changes as shown in the above table.
DIMENSIONS
LOCK
55.0
H:M:S 1 2
Transparent Cover
5.5
GRID RING
SCREW TERMINATION
LCD
89.0
48.0 SQ
LOCK
55.0
H: M: S 1 2
Transparent Cover
5.5
GRID RING
11
Digital Hour Meters & Counters
FEATURES
• Easy to read 6-digit LCD.
• Exceptional reliability with in-built nonvolatile
memory (EEPROM) retaining data for 100 years.
• Wide range of supply voltage.
• “Electrical Reset” terminal for Counters and Hour
Meters and “Enable” terminal for Hour Meters.
• Available in 3 different Bezels.
• Low power consumption.
ROUND BEZEL
SPECIFICATIONS
12
Digital Hour Meters & Counters
CONNECTIONS
DIMENSIONS
ROUND BEZEL
+0 5
Black Bezel
Ø4 )
Thumb Nut 4 mm
(2
.
X
1 2
4 3
24 × 48 BEZEL
1 2
24.0
20.0
4 3
48.0
22.1
44.6
2.0 Recommended Panel Cutout :
+0.5 +0.5
45.5 mm x 23.0 mm
.2
.5
(2
1 2
31.1
23.5
26.5
4 3
All dimensions in mm
CG International
International Operations of
Crompton Greaves Limited
‘Jagruti’, Kanjurmarg (East),
CG.ID/55/Digicon/3/03