Professional Documents
Culture Documents
Mediclean
Company
In contrast to conventional
plug-in appliance.
covered by a 30 mm thick
operational conditions.
commissioned ex works.
commissioning becomes
refrigerant.
maintenance purposes.
to clean.
Mediclean
3
3
1
4
5
7
tional availability.
inspection windows
lows:
ohne Zustze
classification G 3
Dampfbefeuchtung aus-
microorganisms
inspection openings
Single to
three module
downflow
Two module
downflow
Singlemodule
downflow
Singlemodule
upflow
25.2
790
283
790
283
1325
850
35.2
1060
850
45.2
1060
850
1325
850
790
283
38.2
15.2
1060
850
1325
495
38.2
15.2
545
495
1325
495
545
495
1060
850
1325
850
Programme Range
65.2
1325
850
60.2
55.2
1060
850
55.2
1060
850
1325
850
1325
850
1575
1100
1325
1100
85.2
1325
1100
75.2
75.2
1325
850/1100
75.2
1325
850/1100
1325
1100
1575
1100
90.2
1575
1100
120.2
2105
850
120.2
2105
850
180.2
2105
1100
180.2
2105
1100
220.2
2370
1100
220.2
2370
1100
1575
1100
90.2
1575
850/1100
90.2
1575
850/1100
Mediclean
Installation Versions:
Options in the 35.2 H 85.2 H Series
e. g. MEDI 35.2 DXD 13.10.10.8 HS
Return/fresh air
1950
Version 1:
Air conditioning cabinet
System Weiss designed for air
conditioning with all thermodynamic air conditioning
functions: heating,
cooling, humidifying and
dehumidifying.
Fresh/
return air
Supply air
extraction
1060
850
Humidifier module
1325
850
Return air/
extracted air module
1060
850
Fresh air/
supply air module
Application Example:
Three Module Air Conditioning Cabinet
M
min. H 13
min. H 13
min. H 13
min. H 13
min. H 13
min. H 13
900 m /h
150 m3/h
150 m3/h
Adjoining room 1
Operating
theatre
OT
corridor
e. g. 2400 m3/h
1200 m3/h
e. g. 2400 m3/h
2400 m3/h
F5
KO
F5
15 m3/m2 x h
F7/9
MEDICLEAN
Fresh air
Extracted air
150 m3/h
150 m3/h
Adjoining room 2
M
Fig. 1: Schematic diagram, illustrating an air conditioning cabinet System Weiss integrated in a room air system,
as described in version 1.
Installation Versions:
Options in the 35.2 H 85.2 H Series
e.g. MEDI 35.2 DXD 13.10.8 HS
Fresh/
return air
1950
Return/fresh air
extraction
supply
1325
850
Return air/
extracted air module
1060
850
Fresh air/
supply air module
Application Example:
Two Module Air Conditioning Cabinet
Sound absorber
min. H 13
Sound absorber
min. H 13
min. H 13
min. H 13
min. H 13
min. F7
Circulating air
Sound
absorber
min. H 13
min. F7
Clean air
Clean air
1200 m3/h
Circulating air
300 m3/h
Operating
theatre
300 m3/h
Adjoining room 1
OT
corridor
e. g. 8400 m /h
300 m3/h
300 m3/h
Adjoining room 2
1200 m3/h
overflow
Sound
absorber
e. g. 3000 m3/h
1200 m3/h
F5
F7/9
F5
KO
Extracted air
MEDICLEAN
Fresh air
Fig. 2: Schematic diagram, illustrating an air conditioning cabinet System Weiss integrated in a room air system,
as described in version 2.
Mediclean
Installation Versions:
Options in the 35.2 H 85.2 H Series
e.g. MEDI 35.2 DXD 10.8 H
Fresh air/
return air
1950
Version 3:
System Weiss air conditioning cabinet, consisting of a fresh air/supply air module based on
the details given in version 2. Design includes
return air/extracted air flow (ducting side) and
direct evaporation requiring a separate aircooled condenser.
supply
1060
850
Fresh air/
supply air module
Application Example:
Single-Module Air Conditioning Cabinet
Sound absorber
min. H 13
Sound absorber
min. H 13
min. H 13
min. H 13
min. H 13
min. F7
Circulating air
Sound
absorber
min. H 13
min. F7
Clean air
Clean air
Circulating air
300 m3/h
300 m3/h
Operating
theatre
Adjoining room 1
OT
corridor
e. g. 5700 m /h
300 m3/h
3
1400 m /h
300 m3/h
Adjoining room 2
overflow
Sound
absorber
e. g. 2000 m3/h
Fresh air
F5
e. g. 2000 m3/h
M
Air-cooled
axial condenser
MEDICLEAN
F7/9
M
Extracted
air
Fig. 3: Schematic diagram, illustrating an air conditioning cabinet System Weiss integrated in a room air system,
as described in version 3.
Installation Versions:
Options in the 35.2 H 85.2 H Series
e. g. MEDI 85.2 DXD 13.15.11 H
Version 4:
Air conditioning cabinet System Weiss.
Air conditioning with all thermodynamic
air conditioning functions and return
air/extracted air flow. The version with direct
evaporation illustrates the separate air-cooled
condenser required.
Fresh/
return air
1950
Supply air
1325
1100
Humidifier module
1575
1100
Fresh air/
supply air module
functions:
control
password.
The Weiss PC 2 Control System for
Energetically optimised
Mediclean
Process Control 2 (PC 2)
connections
toring
refrigeration)
Accessories
of Following Conditions
limit values
humidifying shutdown
Control parameters
supply
Process Control 2
monitoring
(F5/7/9 and S-filter)
Energetically optimised
with max. supply air
Monitoring
System Peripherals
building services.
WEISS KLIMATECHNIK
EIN
RLT
Pressure-sensitive speed
following accessories:
System on
Alarm 1
Cooling
!
Alarm
Line
Heating
Humidification
On
Off
Dehumidification
Optimised actuation
Status 1
Status 3
Status 5
system
Status 7
and time
Alarm 2
Status 2
Enter
Menu
Reset
local printer
Alarm
Status 4
Status 6
Status 8
Status 9
Integrated in Cabinet
continuous-control fans
for fans,
frequency transformer,
refrigeration modules,
power-controlled compressors
steam humidifying
of filters
Product Type
= part of product key
25.2
35.2
65.2
85.2
m3/h
Pa
2500
700
3500
700
6500
700
8500
500
m3/h
Pa
2250
500
3150
500
5850
500
7650
500
14.5/11.4
17.9/14.7
32.9/26.5
47.2/37.8
19
21.8
piece
mm
kW
A
kVA
1/min
IP
1
R 417 A
5.5
41.3
SCROLL compressor
1
2
R 417 A
R 417 A
6
2x6
3
R 417 A
3x6
DX
DX
DX
DX
60.2
piece
kW
kVA
A
1/1
5.5/5.5
8.3/8.3
12/12
piece
1/1
F5
300
2/3
F5
300
Bag filter
3/3
F5
300
2/2
F5
300
piece
Pa
1
F7
300
2
F7
300
Cassette filter
3
F7
300
3
F7
300
piece
A
kW
kVA
kg/h
bar
S/cm
2
2 x 8.5
2 x 5.5
2 x 5.5
2x7
1 10
125 900
Pa
1/1
5.5/5.5
8.3/8.3
12/12
2
2 x 26
2 x 17.5
2 x 17.5
2 x 23
1 10
125 900
All performance figures are maximum values without filter pollution. Project specific data can only be calculated with details of the
required modules, the air volume flow and the pressure loss. Please use the fax form from the back of this brochure.
10
Mediclean
Max. Three Module
Product Type
25.2
35.2
65.2
85.2
39
1.7
30.2
15
40
55.4
2.4
23.3
15
38
92.5
4
32.1
20
37
114
5
19.9
25
27
13.7
18.7
28.6
35.8
mm
mm
mm
2370
850
1950
1060
850
1950
1325
850
1950
1575
1100
1950
mm
mm
mm
1060
850
1950
1325
850
1950
1325
1100
1950
mm
mm
mm
1325
850
1950
1325
850
1950
1575
1100
1950
mm
mm
mm
2370
850
1950
3445
850
1950
3975
850
1950
4475
1100
1950
10.10.13.8
13.13.13.8
15.13.15.11
81
89
79
87
70
66
82
90
79
87
70
66
28
33
83
91
81
89
71
67
400/3/50
41
65.2 DXD 13.13.13.8
86
94
84
92
74
70
65
85.2 DXD 15.13.15.11
85.2
DXD
15.13.15.11
HS
All performance figures are maximum values without filter pollution. Project specific data can only be calculated with details of the
required modules, the air volume flow and the pressure loss. Please use the fax form from the back of this brochure.
11
Product Type
= part of product key
25.2
35.2
65.2
85.2
20/14
3.1
27.6
20
21
27.9/19.7
4.4
30.1
25
22
46.2/33.4
7.2
29.2
25
50
57.9/42.2
9
28.8
32
32
CW
CW
CW
CW
14.3/11.3
2.1
13.4
20
13
20.6/16.2
2.9
14.8
20
21
33.6/27.2
4.8
14.1
25
23
41.5/34
5.9
13.5
32
15
CW
CW
CW
CW
10/9.8
1.7
9.7
15
16
14.3/13.9
2.5
10.5
20
15
24.3/24.3
4.2
10.7
25
20
30.7/30.7
5.3
10.7
32
13
CW
CW
CW
CW
1400/1450
1300/1350
1050/1100
900/930
Directly driven, free running, backward curved blades
1/1
1/1
1/1
1/1
560/560
560/560
560/560
560/560
EC external rotor
5.8/5.8
5.8/5.8
5.8/5.8
5.8/5.8
13.5/13.5
13.5/13.5
13.5/13.5
13.5/13.5
9.4/9.4
9.4/9.4
9.4/9.4
9.4/9.4
2200/2200
2200/2200
2200/2200
2200/2200
54/54
54/54
54/54
54/54
F/F
F/F
F/F
F/F
Electronic commuting unit for infinitely-adjustable speed Control frequency transformer
piece
A
1/1
14.5/14.5
1/1
14.5/14.5
piece
1/1
F5
300
2/3
F5
300
Pa
1/1
14.5/14.5
Cassette filter
3/3
F5
300
1/1
14.5/14.5
2/2
F5
300
All performance figures are maximum values without filter pollution. Project specific data can only be calculated with details of the
required modules, the air volume flow and the pressure loss. Please use the fax form from the back of this brochure.
12
Mediclean
Max. Three Module
Product Type
25.2
35.2
1/1
F5
300
2/3
F5
300
Cassette filter
3/3
F5
300
2/2
F5
300
1
F7
300
2
F7
300
Bag filter
3
F7
300
2
F7
300
1
F9
300
2
F9
300
Cassette filter
3
F9
300
3
F9
300
kW
m3/h
kPa
DN
kPa
22.8
1
17.6
15
14
32.2
1.4
19.3
15
14
53.1
2.3
26.5
15
33
66.5
2.9
30.5
15
48
kW
m3/h
kPa
DN
kPa
24.5
1.1
16.9
15
15
21
0.9
9.1
15
9
36.1
1.6
11.5
15
23
46
2
13.6
15
33
piece
1
KLD 3
8500
56
1
230
27
3.3
1.3
1100
1050
563
563
1050
109
1
KLD 3
8500
56
1
230
27
3.3
1.3
1100
1050
563
563
1050
109
piece
piece
Pa
Pa
m3/h
dB(A)
piece
V
kW
A
kVA
mm
mm
mm
mm
mm
kg
Version (V)
Vertical air exit
65.2
85.2
1+1
KLD 3 + KLD 6
8500 + 18400
61
1+2
230
27 + 64
3.3 + 2 x 3.3
1.3 + 2 x 2.6
1100 + 2590
1050 + 1050
563 + 563
563 + 563
1050 + 1050
109 + 217
Version (H)
Horizontal air exit
13
Supply
flange
right
equipment
side
A
C
C
B
Supply
flange
left
equipment
side
Humidifier
C
Disconnection flange, height 130 mm
Disconnection flange with valve, height 130 mm
Mediclean
Product Type
25.2
35.2
65.2
85.2
Equipment dimensions0
Width
Depth
Height
mm
mm
mm
2370
850
1950
3445
850
1950
3975
850
1950
4475
1100
1950
mm
mm
mm
mm
mm
mm
mm
mm
mm
675 x 650
675 x 650
675 x 650
670 x 400
670 x 400
670 x 400
670 x 400
670 x 400
670 x 400
675 x 820
675 x 1085
675 x 820
920 x 400
1190 x 400
920 x 400
670 x 400
670 x 400
670 x 400
675 x 1085
675 x 1085
675 x 1085
1190 x 400
1190 x 400
1190 x 400
670 x 400
670 x 400
670 x 400
925 x 1300
925 x 1300
675 x 1085
1440 x 400
1440 x 400
1190 x 400
920 x 400
920 x 400
670 x 400
16
16
1
1
1
1
1/2
16
16
1 1/4
1 1/4
1
1
1/2
22
16
1 1/4
1 1/4
1 1/4
1 1/4
1/2
22/16
16/16
1 1/2
1 1/2
1 1/4
1 1/4
1/2
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
Connections0
Left equipment side high, low, on the side
Refrigerant/Hot gas pipe
mm
Refrigerant/Liquid pipe
mm
CWP inlet
CWP return
HWP inlet
HWP return
14
Mediclean
Control Diagram (DX and CW)
Fresh
air
F5/7
M1
F7/9
H13
Supply
air
FU1
P2
KM1
P1
KO
Extracted
air
Return
air
F5
M1
M2
FU2
Fresh
air
F5/7
M1
F7/9
H13
Supply
air
FU1
P2
P1
Extracted
air
M1
M2
F5
Return
air
FU2
15
e-mail
Fax no.:
Telephone no.:
Project designation
Place
Postal code
a System
2 modules
1 modules
As Version
Pa
Pa
m3/h
m /h
G4
F5
F7
F9
Cooling capacity
C /
% r. h.
kW
Active cooling with
Chilled water pump
Heating performance
kW
Humidific. performance
kg/h
Switching cabinet
% r. h.
m /h
C /
C
Cold water pump
Steam from
interior source
wired to terminals
with power unit, without regulation
with power unit, with regulation
Other accessoires
by
Budget price
by
Tender texts
by
Unit data
by
System plan
further consulting
D-Nr. RK 4.0.0.103 E/58012
We Need:
Company