You are on page 1of 26

Tanjung Jati B Training

SOOTBLOWERS

OPERATIONS
SOOTBLOWERS

Tanjung Jati B Training

PT Central Java Power


Tanjung Jati B Units 1 & 2

2 x 660MW (net)

Boiler

Precipitator

FGD Absorber
Tanjung Jati B Training

Sootblowers
The Sootblowers which utilize steam from the
boiler are intended to remove slag and ash
from boiler tube surfaces.
Steam is taken from the Primary Superheater II
Outlet Header. From there, the pressure is
reduced at the Sootblower Blower Reducing
Station to 500 psig or 34.5 barg.

Tanjung Jati B Training

Sootblowers
Slagging & Fouling

Convection
Pass Fouling

Furnace
Slagging

Tanjung Jati B Training

Sootblowers
Slagging & Fouling
FURNACE WALL SLAGGING

CONVECTION PASS FOULING

Tanjung Jati B Training

Sootblowers
Slagging & Fouling
Percentage of Calcium (CaO) and
Magnesium (MgO)
- High amounts cause furnace ash to be reflective reducing furnace
heat transfer

Percentage of Sodium (Na2O)


- High amounts cause more tenacious fouling of superheat/reheat
surfaces

Ash Fusion Temperature

- Low ash fusion temperature can cause superheat slagging


Tanjung Jati B Training

Sootblowers
Quantity

There are three (3) types of Sootblowers


62 - Long retractable (IK) PSH-I, PSH-2, SSH & RH
8 - Extended Lance (IKEL) Economizer
36 - Short Retract (IR) Furnace Walls

Tanjung Jati B Training

Sootblowers
Location
Thermoprobe
IK Long Retract
Blowers

IK Long Retract
Blowers

IR Short Retract
Wall Blowers

IKEL Short
Retract Blowers

Tanjung Jati B Training

Sootblowers
IR Furnace Wall Blower

MOTOR

CONTROL BOX
NOZZLE

POPPET VALVE
&
ACTUATING ARM
STEAM
Tanjung Jati B Training

Sootblowers
IR Furnace Wall Blower

TYPICAL INSTALLATION

STEAM JET
Tanjung Jati B Training

Sootblowers
Alignment

In order to minimize erosion, alignment


of the sootblower assembly is critical due to
the close proximity of the blower nozzle to
the boiler tubes.
Alignment is set during Construction.

Tanjung Jati B Training

Sootblowers
IR Furnace Wall Blower
y

B
O
I
L
E
R
W
A
L
L

INSTALLATION CHECKS

900

900
z

1-1/2

Center line of nozzle is


1-1/2 from the crown
of the wall tubes
Nozzle is pointing down
or up with the grain of the
tubes in the blowing
position
Must be perpendicular to
the boiler wall In all planes
Check to ensure piping is
supporting the blower with
hangers installed properly

Sootblowers
IK Blower

Tanjung Jati B Training

Sootblowers
Typical IK Blower

Tanjung Jati B Training

Sootblowers
Typical IK Blower

CLEANING HELIX

Tanjung Jati B Training

Sootblowers
Cleaning Dynamics
Cavity Geometry
Deposit Composition
Gas Stream Temperature
Nozzle Distance
Travel Speed
Helix
Blowing Pressure

Tanjung Jati B Training

Sootblowers
Cleaning Dynamics
Temperatures
Steam
300- 450 F

Boiler tube
1000 F
Ash Deposit

Molten or plastic
surface condition
Up to 2400 F

Tanjung Jati B Training

Sootblowers
Pressure Reducing Stations

There are two (2) Pressure Reducing Stations,


one for the Boiler Sootblowers and one for
the Air Heater Sootblowers.

Tanjung Jati B Training

Sootblowers
Steam Source
TO SOOTBLOWER
REDUCING STATION

STEAM DRUM

PSH-I

PSH-II

SSH
HP TURBINE

TO IP TURBINE
REHEATER

Tanjung Jati B Training

Sootblowers
Steam Pressure Reducing Stations

Tanjung Jati B Training

Sootblowers
Control

Operating the sootblowers is accomplished


through the DCS system. Various blowing
sequences can be preprogrammed or the desired
number of sootblowers can be selected
manually.

Tanjung Jati B Training

Sootblowers
Blowing Frequency

Determining how frequent the Boiler and


Air Heaters will require sootblowing is based on
the fuel being fired and related Boiler
Performance.
A Sootblowers steam blowing pressure will be
determined during commissioning.

Tanjung Jati B Training

Sootblowers
Blowing Pressures

If removal of slag or fouling (ash) is not being


removed effectively, the blowing pressure can
increased.
Increased steam pressure results in higher
steam velocities. However, higher steam velocities
increase the potential for tube erosion.

Tanjung Jati B Training

Sootblowers
Failure to Retract

If a sootblower becomes stuck in the boiler


NEVER, NEVER close the sootblowers
Isolation Valve. Steam acts to cool the
Blower and protect it from heat damage.
A Special Retracting Tool is provided to
retract the blower.

Tanjung Jati B Training

OPERATIONS
SOOTBLOWERS
(END)