Features
Precision high voltage resistor
Frequency compensated
High overload capability
Passive network application, no auxiliary power necessary
High electromagnetic compatibility (EMC)
low temperature drift
Application
This specially designed ohmic voltage sensor type of GSER 16 is developed to operate as an addon for YOKOGAWA Power Analyser WT3000. It is suitable for monitoring and measuring direct,
alternating and mixed voltages for motor management purposes and power quality analysis. It is
independent from any auxiliary power supply.
Voltage sensors are required instead of VTs if the primary voltage contains dc components and/or
higher frequencies.
Description
The GSER 16 ohmic voltage sensor forms a measuring unit consisting of a high voltage resistive
divider (R1,R2) and a preventive electromagnetic shielding (S).
The resistive divider translates the high voltage into a low power voltage signal, which is exactly
aligned to the WT3000 voltage inputs (10M; 5pF). The electromagnetic shielding provides high
EMC and makes the GSER 16 suitable for use in environments with heavy external interferences
and disturbances.
A wide frequency range is achieved by compensating (Cf and cable capacity) unwanted influences
of parasitic capacitances that results from the mechanical design of the sensor.
TE154-65a(3)
Data sheet
General description
Output cable
Functional principle
ohmic divider
frequency compensated
Cable type
Outline Drawing
similar to MB3.5988
Length, L
Design
Application
Standard
(typ.)
Insulation level
18 kV
Rated power-frequency
withstand voltage, 50Hz,
1 min
50 kV
Pcont. max.
Primary rated voltage,
Upn
Rated lightning-impulse
withstand voltage (peak),
1,2/50s
150 kV
Frequency, rated, fn
50/60 Hz
50
Electrical data
Type
RG 58C/U
coaxial
Service conditions
Environment
Ambient temperature:
-5 ... +40C
10' max.
Min. flashover
250 mm
Frequency range
(max 5%)
Min. creepage
530 mm
Insulator colour
Input resistance
20 M 5%
Weight approx.
22 kg
Input capacitance
Height approx.
341mm
Rated burden
Diameter approx
220mm
short-circuit protected
Error at fn,
Phase displacement
at fn,
0,2% max.
Notes
(1) Other values on request
(2) Other burdens on request
(3) Option outdoor on request
TE154-65a(3)
Mounting:
Vertical or horizontal with terminal
box downward
Weight approx.
Flashover distance, min
Creepage distance, min
22kg
250mm
530mm
1.
2.
3.
4.
5.
6.
Cast resin
Rating plate
cable gland Pg 9
Electronic box
Bottom plate of galvanized steel
14 grounding point (internal
connected to electronic box)
7. Insert nut of stainless steel
8. Primary screw M10 of stainless steel
9. Output cable
TE154-65a(3)