Professional Documents
Culture Documents
th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:
FOTHELO
Page:
Project:
Fastening point:
Date:
1
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015
Specifiers comments:
Design standard:
EC2 / ETA
Application type:
1. Loads
Loads
Md
Md,xz
Drilling
Structure
0.00 kNm
Hole condition
Dry
C20/25
0.00 kNm
Drilling method
Hammer drilling
500 N/mm
Drilling aid
500 N/mm
Nd
140 kN
Highest
17.5 kN/bar
Lowest
17.5 kN/bar
Fire design
Fire rating
Temperature (EC2/ETA)
During installation
from 5 C to 40 C
During service
20 C / 20 C
None
Fatigue design
None
Seismic
Seismic loads
No
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:
FOTHELO
Page:
Project:
Fastening point:
Date:
2
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015
4. Eurocode 2 parameters
5. Existing reinforcement
6. Post-installed reinforcement
cc
1.00
Longitudinal reinforcement
Reinforcements parameters
ct
1.00
Bar size
16.0 mm
Diameter
25.0 mm
Concrete cover
40.0 mm
Spacing - Y
162 mm
Number of bars
4x4
Spacing - X
162 mm
25.0 mm
ct,bond
1.00
ud
0.0200
k2
0.850
Bar size
10.0 mm
cd (EC2, 8.4.4.1)
68.8 mm
'
0.920
Concrete cover
40.0 mm
Bond conditions
Good
max
0.0400
Spacing
250 mm
Min. reinforcement
100 mm/m
c2
2.0010-3
Parameters
c2u
3.5010-3
0.700
Transverse pressure
0.00 N/mm
0.700
0.00 mm
Bond conditions
Good
Transverse reinforcement
Other
30.0 mm
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:
FOTHELO
Page:
Project:
Fastening point:
Date:
3
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015
Selected solution
Bar size
Bar spacing - Y
centre/centre
Bar spacing - X
centre/centre
Distance
centre/surface
Drilled hole
required
Anchorage for
yield of bar
[mm]
D [mm]
s [mm]
s [mm]
cs [mm]
vreq [mm]
vy [mm]
25.0
32.0
163
163
238
577
1,353
Bar with
highest load
Required accessories
Drilling
Cleaning
Setting
FE
17.5 kN
Stress in bars
sd
35.7 N/mm
Adhesive used
Good 1
1.00
(input)
Bond strength
fbd,pi
2.30 N/mm
ETA 08/0105
lb,rqd = (/4)(sd/fbd,pi)
96.9 mm
lb,rqd,fyd = (/4)(fyd/fbd,pi)
1.50
fmult,min
1.00
532 mm
cd
68.8 mm
Influence cover/spacing
Transverse reinforcement
110 mm
40.3 mm
K-factor
1,181 mm
0.738
0.0500
2
Transverse pressure
0.00 N/mm
1.00
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
0.993
www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:
FOTHELO
Page:
Project:
Fastening point:
Date:
4
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015
= {235 0.7}
0.732
532 mm
Bond condition
Good 1
1.00
Bond strength
fbd,ci
2.32 N/mm
lb,rqd = (/4)(sd/fbd,ci)
100 mm
lb,rqd,fyd = (/4)(fyd/fbd,ci)
749 mm
1.50
fmult,min
1.00
337 mm
cd
Influence cover/spacing
Transverse reinforcement
112 mm
65.5 mm
K-factor
0.700
40.0 mm
0.775
0.0500
2
0.995
Transverse pressure
0.00 N/mm
1.00
= {235 0.7}
337 mm
l0 = max(l0,pi; l0,ci)
532 mm
79.8 mm
l0,e = max(e-4; 0)
15.8 mm
Front cover
cf
30.0 mm
0.771
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
(input)
www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:
FOTHELO
Page:
Project:
Fastening point:
Date:
Installation length
5
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015
linst = l0 + l0,e + cf
577 mm
FE
17.5 kN
Stress in bars
sd
35.7 N/mm
Adhesive used
Good 1
1.00
(input)
Bond strength
fbd,pi
2.30 N/mm
ETA 08/0105
lb,rqd = (/4)(sd/fbd,pi)
96.9 mm
lb,rqd,fyd = (/4)(fyd/fbd,pi)
1.50
fmult,min
1.00
532 mm
cd
68.8 mm
Influence cover/spacing
Transverse reinforcement
1,181 mm
0.738
110 mm
40.3 mm
K-factor
Transverse pressure
0.00 N/mm
1.00
= {235 0.7}
532 mm
Bond condition
Good 1
1.00
Bond strength
fbd,ci
2.32 N/mm
lb,rqd = (/4)(sd/fbd,ci)
100 mm
0.0500
0.993
0.732
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
(input)
www.hilti.co.th/holth
Company:
Specifier:
Address:
Phone | Fax:
E-Mail:
FOTHELO
Page:
Project:
Fastening point:
Date:
6
ANCHOR SUITES SIGNAGE
Node no 11
15/07/2015
lb,rqd,fyd = (/4)(fyd/fbd,ci)
749 mm
1.50
fmult,min
1.00
cd
Influence cover/spacing
Transverse reinforcement
337 mm
0.700
40.0 mm
K-factor
0.775
112 mm
65.5 mm
0.0500
0.995
Transverse pressure
0.00 N/mm
1.00
= {235 0.7}
337 mm
l0 = max(l0,pi; l0,ci)
532 mm
79.8 mm
l0,e = max(e-4; 0)
15.8 mm
Front cover
cf
30.0 mm
Installation length
linst = l0 + l0,e + cf
577 mm
0.771
Remarks
This design exclusively considers the local load transfer from the post-installed tensile reinforcement at the intersection between new and existing
concrete. The joint surfaces for concreting must be roughened to at least such an extent that aggregates protrude. It assumes that adequate
transverse reinforcement is provided in the anchorage area if required.
The shear load carrying capacity of the cross section has to be designed separately.
The Installation (drilling, cleaning, setting) must be according to the approval!
Fixed diameter and spacing selected. Please be aware that over-reinforcement of the section may lead to brittle failure of the fastening.
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan