PMUChallengesandDrivers
Requirementsforthedata
Generalcontrolaspects
Wideareacontrol
SpecialProtectionSystems
SituationalAwarenessandapplicationswithintheDistributionSystem
PMUsandtheiruseinMicrogrids
Conclusion
Beforelookingatcontrolapplications,considersomeofthe
parametersrequiredfromaPMU.
Fromameasurementpointofview:
Accuracy
Repeatability
Timelyavailability
Stabilityofthereadings
Capabilityofdetectingkeyharmonics,
DRIVERS
Increasingcomplexityofthegrid.Needofnetworkmonitoring
andcontrolinrealtime.
Increasingdemand.Needofincreasingthepowerflowwith
existinginfrastructure.
Systemoperatorsneedsynchronizedinformationtomake
decisionsinlinewithnetworkrequirements.
Needtoimprovetheoperationalsecurityofthepowersystem.
Afterharmfulblackouts,theneedtopreventapowersystem`s
collapsesemerges.Theneedforaccurateandrealtime
informationiscritical.
Reliableandhighlyeffectiveatrejectingharmoniccomponents,
includingsubharmonicscausedbyseriescompensation
Performsverywellinstressedanddisturbedpowersystems,
providinggoodandreliablemeasurementsandfasteroperation
ofcontrolandprotectionsystems.
Exceptionalreportingratethatallowsimplementationoffast
intelligentprotectionandcontrolschemes,specialprotection
schemes,etc.
Resiliencetoharmonicsprovidesanidealapproachfor
singlephaseapplications,microgrids andpowerislands.
APMUwithadaptivealgorithmsoperatingunderawide
frequencyrangeforphasor &frequency(especiallyindynamic
conditions)mustworkwithina 15to20Hzrangefromthe
selectedbasefrequencyandshouldnottobeaffectedby
harmonics,intermodulation,subandhypersynchronous
resonances.
1.
Fundamentalfrequencyrangefc=5466Hz however,thedevicemustwork
intherange4070Hz(bindtohydrogeneratorsrequirements)
2.
RateofChangeofFrequency(ROCOF)range3Hz/s however,thedevice
mustworkupto6Hz/s.Thealgorithmsshouldremainstableupto25Hz/s.
3.
Outofbandfilteringofseriesdampedresonanceintherange2532Hz,
(2.5%onvoltagemorethan10%oncurrent)
4.
Outofbandfilteringofparalleldampedresonanceintherange70100Hz
(upto10%onvoltage)
8
5.
Outofbandfilteringofsubsynchronousparallelresonances
{intherangefss =520Hz(5to25%)}
6.
Intermodulationrejection(duetocouplingoftransformersaturationandsub
synchronousparallelresonance)intherange:
fi=fc fss andfi=fc 2fss(5%onthevoltage)
7.
Harmonicsrejection(5%for2ndto5thand2%from6thto10th)atthe
fundamentalandatoffsetfrequencies(5466Hz).
6.
ShouldexceedtherequirementsofC37.118.1forbothMandPclassaccuracy
(thusprovidingawiderlinearityrangethanwhatisspecifiedinthestandard)
Uniquecapabilitytoidentifytheusersselectedharmonicswithinthemeasurement
samplingstream,(certainharmonicsarenormallyusedaskeydetectionpointsina
numberofapplications.Example:solarstorms).
10
Preparestheinformationwithinthecontextofthe
requirementsoftheoverallcontrolobjectives
Controlaspectmustbeplannedforhavingthecapabilityof
performingcontrollocallyorviacommunications
Mustbeabletoselectthecommunicationmediumand
protocols
C37.118(withanydesiredframerateupto240)
61850905(forPMUdatatransmission)
GOOSEmessaging(in/out)
11
Since2004,HydroQubechasbeenoperatingaPMUnetwork
ConnectedtotheEMSforthepurposesofGICearlywarninginrealtime
FrequencymeasurementforAGCbackupinputsignal
UseddailyforSPSperformancereportingtoNERC
Playsamajorroleinblackoutforensics
Nowbeingdeployed anewWAMSforallmajor735kVsubs
(withdynamicshuntcompensators)
UsingthelatestC38.118.1gradeofPMUs
TogetherwithimprovedSPDC(SubstationPhasor DataConcentrator)
Deployedmorespecificallyforwideareaandlocalvoltagecontrolto
boostreactivepower
12
VisiondevelopedattheHydroQuebecResearch(IREQ)
Equipall735kVwiththeadvancedPMUs
EquipallwindfarmswithPMUs
Thiswillallowrobustsynchrophasor analyticsfor:
Gridperformancemonitoring
Forensics
Thegoalofthisapproach
EvolvetowardswideareaSpecialProtectionSystems(SPS)
Implementdampingcontrollerswhenitmakesgoodbusiness
sense
13
GeoMagneticInducedCurrent(GIC)earlywarning
Analyticsfordecisionmakingrequirecertainkey
harmonics
WideareaSPS
Remoteunderfrequencyloadshedding
Remoteundervoltageloadshedding
Widerangeofnewautomationapplications
14
PMUsprovideinformationtoallowimprovementof
transient&voltagestability
Thesystemswouldoperateat>240framespersecond
Allowingforlocaldampeningofawidevarietyofoscillation
modes
Capabilityforlocalandwideareacontrolcontributionof
shuntcompensationtovoltagecontrol
15
Situationalawarenesswithinthedistributionenvironment
Powerislandingcontrolapplications
Uniquepossibilitiesdowntosinglephaseapplications
ControlwithinMicrogrids
16
Microgrids incorporatemultipletypesofpowergeneration
Windturbines(variousoutputs)
DieselGenerator(s)
Batterystoragesystem(s)
Solar,(PV,Thermal)
17
IncreasedapplicationsusingPMUinformation
Monitoring
Analysis
Alarmingandsituationalawareness
Controlaspectpossibilitiesinmanyareas
18
North America
Europe,MiddleEast
2284,delaProvinceStreet
475LouiseAvenue
Longueuil(Qc)CanadaJ4G1G1 1050Brussels
T:+14506790003
F:+14506799051
sales@vizimax.com
www.vizimax.com
T:+3226690735
F:+3226690739
sales@vizimax.com
www.vizimax.com
India
LatinAmerica
HIG408,Streetno.12
Madhavanagar,
Ramachandrapuram
Hyderabad502032,India
T:+919848822724
sales@vizimax.com
www.vizimax.com
AlamedaIt#1267,Conj.122
Jardins,CEP01421001
SoPauloSPBrazil
115088
.,.5,344
T:+5511963076174
F:+551130819077
sales@vizimax.com
. +74956656279
russia@vizimax.com
www.vizimax.com
19