LUPOY NS5000C

Injection Molding, PC/ABS

Description

Application

Heat Resistance, High Flow, High Impact.

Automotive(Interior)

Properties

Test Condition

Test Method

Unit

Typical Value

250/2.16kg

ASTM D792
ASTM D955
ASTM D1238

%
g/10min

1.14
0.5~0.8
4.8

kg/cm2

540

%
%
kg/cm2
kg/cm2

>100
870
22,000

kgcm/cm
kgcm/cm
-

70
55
114

114

Physical
Specific Gravity
Molding Shrinkage (Flow), 3.2mm
Melt Flow Rate

Mechanical
Tensile Strength, 3.2mm
@ Yield
Tensile Elongation, 3.2mm
@ Yield
@ Break
Flexural Strength, 3.2mm
Flexural Modulus, 3.2mm
IZOD Impact Strength, 3.2mm
(Notched)
Rockwell Hardness

ASTM D638
50mm/min
ASTM D638
50mm/min
50mm/min
10mm/min
10mm/min
23
-30
R-Scale

ASTM D790
ASTM D790
ASTM D256

ASTM D785

Thermal
Heat Deflection Temperature, 6.4mm
(Unannealed)

ASTM D648
18.6kg
4.6kg

Vicat Softening Temperature

ASTM D1525
5kg, 50/h

Ball Pressure Temperature


Burning Rate, 3.2mm
Flammability
0.8mm
1.6mm
2.5mm
3.0mm
Relative Temperature Index
Electrical
Mechanical with Impact
Mechanical without Impact

IEC 60695-10-2
FMVSS 302
UL94

mm
class
class
class
class

UL 746B

Note) Typical values are only for material selection purpose, and variation within normal tolerances are for various colors.
Values given should not be interpreted as specification and not be used for part or tool design.
All properties, except melt flow rate are measured on injection molulded specimens and after 48 hours storage at 23, 50% relative humidty.

Updated : Nov-09, 2009


The information contained herein, including, but not limited to, data, statements and typical values, are given in good faith. LG Chem makes no warranty or guarantee,
expressed or implied, (i) that the result described herein will be obtained under end - use conditions, or (ii) as to the effectiveness or safety of any design incorporating LG
Chem materials, products, recommendations or advice. Further, any information contained herein shall not be construed as a part of legally binding offer. Especially, the
typical values should be regarded as reference values only and not as binding minimum values. Each user bear full responsibility for making its own determination as to the
suitability of LG Chem's materials, products, recommendations, or advice for its own particular use. Each user must identify and perform all tests and analyses necessary to
assure that its finished parts incorporating LG Chem material or products will be safe and suitable for use under end - use conditions. The data contained herein can be
changed without notice as a result of the quality improvement of the products.

LUPOY NS5000C
Injection Molding, PC/ABS

Description

Application

Heat Resistance, High Flow, High Impact.

Automotive(Interior)

Electrical
Comparative Tracking Index(CTI)
Surface Resistivity
Volume Resistivity
Arc Resistance
Dielectric Strength, 1mm
Dielectric Constant (10 6 Hz)

Solution A
23
23
23
23

IEC 60112
IEC 60093
ASTM D257
ASTM D495
ASTM D149
ASTM D150

Volts
Ohm
Ohmm
Ohmcm
kV/mm
sec

Note) Typical values are only for material selection purpose, and variation within normal tolerances are for various colors.
Values given should not be interpreted as specification and not be used for part or tool design.
All properties, except melt flow rate are measured on injection molulded specimens and after 48 hours storage at 23, 50% relative humidty.

Processing Guide (Injection Molding)


Processing Parameters
Drying Temperature
Drying Time
Minimum Moisture Content
Melt Temperature
Cylinder Temperature
Nozzle Temperature
Mold Temperature
Back Pressure
Screw Speed

Rear
Middle
Front

Unit

Value

hrs
%

kg/cm2
rpm

80~100
4~6
0.02
250 ~ 275
240 ~ 270
245 ~ 275
245 ~ 275
245 ~ 275
50 ~ 70
40 ~ 70

Note) Back Pressure & Screw Speed are only mentioned as general guidelines.
These may not apply or need adjustment in specific situations such as low shot sizes, thin wall molding and gas-assist molding.

Updated : Nov-09, 2009


The information contained herein, including, but not limited to, data, statements and typical values, are given in good faith. LG Chem makes no warranty or guarantee,
expressed or implied, (i) that the result described herein will be obtained under end - use conditions, or (ii) as to the effectiveness or safety of any design incorporating LG
Chem materials, products, recommendations or advice. Further, any information contained herein shall not be construed as a part of legally binding offer. Especially, the
typical values should be regarded as reference values only and not as binding minimum values. Each user bear full responsibility for making its own determination as to the
suitability of LG Chem's materials, products, recommendations, or advice for its own particular use. Each user must identify and perform all tests and analyses necessary to
assure that its finished parts incorporating LG Chem material or products will be safe and suitable for use under end - use conditions. The data contained herein can be
changed without notice as a result of the quality improvement of the products.