You are on page 1of 3

Inspection Technologies

www.RosenInspection.net

Tool Data Sheet


24-Nov-2006
Page 1

14 - 16 Inches HiRes Metal Loss Mapping Tool


CDP15"1.5V02.03

Technical Data
General Information
Application on board

Technology

Sensor details

Metal Loss Mapping

Axial MFL

184 MFL Channels

Technical Specifications

Mechanical Specifications

Max. Inspection Range (At optimum tool speed)


268.00 km
Max. Inspection Time
118.4 h
0.50 - 3.90 m/s
Velocity Range
Max. Operating Pressure
15.00 MPa
3.50 MPa
Min. Operating Pressure (Gas)
Product Temperature Range
0 - 65 C
Max. Product Speed for Speed Control Pigs
n/a

Tool Length (T)


Launch Length (S)
Rear Sealing Length (R)
Operational Tool Weight
Transport Tool Weight

Magnetic- and Sensor Specifications

Pipeline Requirements

Wall Thickness Range


Magnetization Level

9.30 mm - 27.40 mm
10 - 30 kA/m

* Higher wall thickness can be inspected at different specifications

Min. Bend Radius


Min. Bore in Straight Pipe
Min. Bore in 3D Bend
Min. Bore in 1.5D Bend
Straight Pipe in-between Back to Back Bends
Max. ID Step Changes
Unbarred Tee Size

3940.00 mm
3781.00 mm
3223.00 mm
845.00 kg
1356.00 kg

1.5 D
302.00 mm
316.00 mm
335.00 mm
788.00 mm
18.00 mm
n/a

Launcher and Receiver Requirements


Trap Dimensions
Launcher (min)

Receiver (min)

A
B
C
D
E
H
L

B
C
D
E
H
L

3940.00 mm
400.00 mm
711.00 mm
359.00 mm
17 inch
4940.00 mm
4940.00 mm

3940.00 mm
559.00 mm
711.00 mm
3940.00 mm
17 inch
4940.00 mm
4940.00 mm

DISCLAIMER: INSPECTION TOOL WILL BE PREPARED ACCORDING TO INFORMATION OBTAINED FROM CUSTOMER.

Inspection Technologies
www.RosenInspection.net

Tool Data Sheet


24-Nov-2006
Page 2

Metal Loss Feature Specification


All reported metal loss feature are being classified according to these dimensions:

Depth at POD = 90% [fraction of t] (e.g. 0.1 x t)


Depth sizing accuracy at 80% Confidence [fraction of t] (e.g. 0.1 x t)
Length sizing accuracy at 80% Confidence [mm] (e.g. 10 mm)
Width sizing accuracy at 80% Confidence [mm](e.g. 10mm)

General
0.1
0.1
15
20

Pitting
0.12
0.15
12
12

AxialCircumferential
grooving
grooving
0.2
0.12
0.2
0.17
15
20
12
20

Notes:
z If t < 10 mm then A = 10 mm. If t >= 10mm then A = t.
z Parameter t is defined as follows:
Wall thickness >= 5 mm: t = wall thickness
Wall thickness < 5 mm: t = 5mm
z POD: Probability of Detection
z Internal/non-internal feature discrimination available.
Wall thickness Measurement
0.5 mm or 0.1t, whichever value is greater at 80%
confidence
Location and Orientation Capabilities
axial position accuracy from
1:1000
reference marker
(1m or 1000m marker distance)
axial position from closest weld
0.1 m
circumferential position accuracy
10
The axial positioning accuracy specified is based on following
conditions:
z Distance between upstream and downstream marker /
reference point < 2000 m
z Actual above ground distance to both u/s and d/s marker /
reference points to be measured and correlated.
z Negligible difference between pipeline and soil contour