DIGITAL INDICATOR
DN500N
CONTENTS
1. INTRODUCTION 2
2. SPECIFICATION 3
3. DISPLAY
4. INSTALLATION
5
9
5. CALIBRATION
10
6. SET-UP
14
7. INTERFACE
24
DIGITAL INDICATOR
DN500N
1. INTRODUCTION
1-1 INTRODUCTION
Thank you very much for purchasing our industrial indicator.
This product has various functions as well as the functions of external interface.
It is designed to satisfy different kinds of requirement in the various industrial sites.
Its external design is also solid and elegant.
It is programmed in users friendly way for easy in use and the message display function
is built-in to help users easy understanding.
Please ready this instruction manual carefully before you use this product so that you can
use this product properly and apply all the functions of this indicator enough.
1-2 ATTENTION
1-4 ACCESSORIES
DIGITAL INDICATOR
DN500N
2. SPECIFICATION
Input sensitivity
0.45 / D
- 0.6mV + 42.0mV
DC 10V (5V)
32mV
Temperature coefficient
ZERO: 20 PPM /
SPAN: 20 PPM /
Input Noise
0.6 P.P
Input Impedance
over 10
A/D Resolution
520,000 Count(19bit)
200times / Sec
Non-linearity
0.01% FS
Display
element
Weight
Part
Weight
Value of 1 division
1, 2, 5, 10, 20, 50
+550000
Under Zero
"-"Minus Sign
Display
Status
K e y
Green LED 3
DIGITAL INDICATOR
DN500N
should be formed)
2-4. OPTIONS
OP1
OP2
OP3
OP4
BCD in - put
OP5
Serial print I/F, RS-232C and Current Loop are installed as standard.
DIGITAL INDICATOR
DN500N
TARE
GROSS : Lamp is OFF when the weight display is for net (excluding tare) and it is
ON when the weight display is for gross (net + tare).
AUTO
: Lamp is on when hold is used on the weight display value. (Peak-Hold, Sample
Hold, Average Hold)
RTxD
DIGITAL INDICATOR
DN500N
DIGITAL INDICATOR
DN500N
HIDDEN KEY
You can change key number if you press the other key within 2 seconds
after you press CLEAR Key.
To display and change TIME
To display and change DATE
To delete SUBTOTAL PRINTER DATA
To delete TOTAL PRINTER DATA
DIGITAL INDICATOR
DN500N
-Power Switch :
POWER
-Fuse :
AC 250V 10A
-AC IN : This product can be used in AC 85V ~ 265V since it uses SMPS power.
OPTION 1,2
LOAD CELL
CONNECTOR (N-16)
Remote-in-put
External Output
(Printer, CURRENT,
Computer communication)
PIN1 (RED)
-EXC - (-5V)
PIN2 (WHITE)
-SIG+
-SIG-
PIN4 (GREEN)
-SHIELD
ISP
(DATA LOCK PIN)
DIGITAL INDICATOR
DN500N
4. INSTALLATION
4-1. EXTERNAL DIMENSION & CUTTING SIZE
(EXTERNAL SIZE mm)
DIGITAL INDICATOR
DN500N
5. CALIBRATION
What is Calibration?
This is to match the displayed numerical value and the actual weight value for displaying
weight.
EX
SET.CAL. displayed.
10
DIGITAL INDICATOR
DN500N
. STEP 1
This step is to set the value of 1 division. (Unit of minimum display division)
Here, d stands for Division and it indicates the value of 1 division
(Minimum division display)
This value change is shown in order of 01-02-05-10-20-50 each time 0 Key
is pressed. After it stopped at a desired value a certain value of 1 division,
press ENTER Key so that the value can be memorized as the value of one
division and then move to the next step.
. STEP 2
This step is to set the maximum display capacity.
Here, CAPA stands for Capacity and it indicates the maximum display capacity
that can be weighed by scale. You should input your desired maximum display
capacity value instead of an optional numerical value currently displayed.
To input, please input the number you want by using the number Key on Key
Board and then press ENTER Key so that the current value will be memorized
and move to the next step.
***
Please do not set (Value of 1 division/MAX display capacity) to be over (1/20,000)
When it is over (1/20,000), Error message will be displayed. You can use up to 1/20,000 only.
. STEP 3
This step is to confirm the current 0 status of scale.
After you check the currently displayed value, please press ENTER Key.
And then the gauge bar will goes up for about 3 seconds.
You will move to the next step automatically.
. STEP 4
SPAN will be shown on capacity display and then it will be changed to
CAPA value which is the value in STEP 2.
If standard span weight of CAPA is not ready here, please prepare for a span
standard weight that is over 10% of CAPA value and then input the value by
using numerical Key and then press ENTER Key so that you can move to the
next step.
At this stage, UP means you have to put the prepared span standard weight
on scale.
After you put on the span standard weight on scale and when the capacity is
stable enough without any impact or vibration, please press ENTER KEY so
that Gauge bar can go up for about 3 seconds and you can move to the next
step.
11
DIGITAL INDICATOR
DN500N
. STEP 5
This span is to display the calculated Span constant.
If indicator displays this condition, it means Span calculation is finished.
If constant value is between 0.50000~1.50000, span is normally calibrated.
If constant value is not between 0.50000~1.50000, you need to do the Span
calibration once again so that you can use the scale with better accuracy.
After span constant is displayed, C_End._ will be displayed and slowly
flashing for about 3 seconds to test the condition of display. Then it will
be displayed as normal operation mode for measuring.
Now, Span Calibration is completed.
you need to prepare for a standard weight that is over 10% of Max display division
and then set the value. When it is more than 1/5,000, you need to prepare for a standard
weight that is over 20% of Max display division and then set the value. This is to do the span
calibration with better accuracy.
- If you do the setting a weight over Max display division, an Error Message
Err 04 will be displayed.
- If you do the setting a weight below 10 % of Max display division,
an Error Message Error 05 will be displayed.
12
DIGITAL INDICATOR
DN500N
No.
MESSAGE
CAUSE
SOLUTION
Err 01
20,000
Err 04
setting
is
over
Maximum
division.
Err 05
Err 06
weight
according
to
the
value
correctly.
- Please check if standard weight is less than
Err 07
Err A
Err _8
13
DIGITAL INDICATOR
DN500N
6. SET-UP
6-1. SET-UP
SUMMARY
It is to set F-FUNCTION properly according to the actuator of scale and surroundings so that
the scale can be operated on the optimized condition.
ENTERING SET-UP
When Power is OFF, please keep pressing 3 Key, and then Power will be ON and the main display
will show TEST.
Now press 3 Key again and the main display will show SET. CAL.
Then press CLEAR Key and F01-XX will be displayed.
EX
EX
14
DIGITAL INDICATOR
DN500N
HOW TO CHANGE SETTING FOR F-Function
To change setting for F-Function, you need to ender the number you want with number Key and
press ENTER Key so that it will be saved in the internal Memory and the change is completed.
Please remember if you enter only number Key and dont press ENDER Key the value cannot be
saved.
EX
TEST Mode
TEST
TEST1
TEST2
TEST3
SET.CAL Mode
TEST4
TEST5
TEST6
TEST7
TEST8
Description
15
DIGITAL INDICATOR
DN500N
DESCRIPTION
DIVISION
Select Set-UpCalibration
Divided into CLR and Input ENTER
Set the location of decimal Point
0, 0.0, 0.00, 0.000
Zero Memory Mode.
Normal(0), Back UP(1)
MOTION BAND Range
0, 1, 2, 3
ZERO TRACKING Range
0, 1, 2, 3
Set AUTO ZERO Range
0099
Digital Filter Range
19
ZERO, TARE Key Operation Mode
Steady(0), Unsteady(1)
Set ZERO Key Operation Range
2%(0), 5%(1), 10%(2), 20%(3), 100%(4)
Set TARE Key Operation Range
10%(0), 20%(1),50%(2),100%(3)
Set HOLD function
Peak-hold(0), Sample hold(1),8Sec Average Hold(2)
Set External Input
0,1,2,3,4
Appoint Code number
0,1,2
Set S/N Key Operation
0,1
Time for Hold OFF
0.0 9.9 Sec
Set Serial 2 Parity Bit
NO(0), ODD(1), EVEN(2)
Serial 2 Communication Speed
0 9 , 115200 bps 2400 bps
0
:
Stream
Mode, 1 : Steady Mode, 2:PRINT KEY
Serial 2 Communication Mode
0:One-way Transmit Mode, 1:COMMAND MODE, 2:LCD MODE
Serial 2 Communication Method
Set ID NUMBER
199
0
:
Basic
FORMAT
,
1
:
Basic+Time , 2 : CAS FORMAT
Transmit Data FORMAT
Select BCC
0 : BCC No Use 1 : BCC Use
Set Weighing Unit Print
0:kg, 1:g, 2:ton
Select Data Output with Auto Printer
0 :F80 Setting
, 1 : Steady Lamp
0 : Korean 1 : English
09.9
0: Key Tare No Use,1: Key Tare Useable
AUTO FUNCTI0N SETTING
x x x x x x
x x x x x x
x. x x x x x
x x. x x. x x
x x. x x. x x
16
DIGITAL INDICATOR
DN500N
( Factory Default)
SET LOCATION OF DECIMAL POINT
F01
No Decimal Point
0.0
0.00
0.000
F02
Normal Mode
Back-up Mode
* On normal condition, it doesnt remember the weight on scale if power failure or Power OFF.
Thus, you need to make Power ON after removing the weight from scale.
* On Back-up condition, it remembers the initial zero value when power failure or Power OFF. So
if there is a weight on scale when Power is on, it displays the same weight value.
If the weight is already removed, you need to press ZERO" Key to make Zero value re-saved.
F03
0 : Weak Vibration
3 : Strong Vibration
* If weight change range in setting time is within A/D count setting Range, it regards this
condition as steady. To have speedy steady condition, please have a big number when the surroundings
have strong vibration and please have a small number when the surroundings have weak vibration.
F04
the display back to Zero when there are small deviations caused
Ex) When Maximum display division is 120.00Kg and the value of one division is set as 0.05Kg:
F04 is set as 3.
If weight change is within 250g in 0.75 Sec,
displays shows 0 automatically.
4.5digit
(0.25Kg)
0.75 Sec
17
DIGITAL INDICATOR
DN500N
SET AUTO-ZERO RANGE
00
F05
20
99
With this mode, you can automatically set Zero without pressing Zero Key before you do measuring again.
F06
Weak
Weak Vibration
Strong
More Sensitive
Strong Vibration
Less Sensitive
This mode should be used after compensating the setting value according to the surrounding
condition (surrounding vibration).
To make the speed of display reply faster, please set the setting value small.
F07
F08
F09
F10
Display is held when Hold key is pressed or external input is made: Sample Hold
Held for 8 sec averaging weight if Hold Key is pressed or external input is
18
DIGITAL INDICATOR
DN500N
EXTERNAL INPUT
Section
F11
IN1
IN2
IN3
IN4
ZERO
Tare
Remove Tare
ZERO
Tare/Remove Tare
Hold
Cancel Hold
ZERO
Tare/Remove Tare
Subtotal
ZERO
Hold
Cancel Hold
ZERO
Subtotal
Total
F12
Fixed
F13
F14
00
9.9
19
DIGITAL INDICATOR
DN500N
SERIAL I/F
SERIAL COMMUNICATION : PARITY BIT SETTING
F30
No Parity
Odd Parity
Even Parity
F31
0
1
115,200 bps
76,800 bps
57,600 bps
38,400 bps
28,800 bps
19,200 bps
14,400 bps
9,600 bps
4,800 bps
2,400 bps
F32
F33
Command Mode
LCD Mode
ID NUMBER SETTING
F34
199
F35
Basic FORMAT
CAS FORMAT
BCC SELET MODE
F36
BCC No Use.
BCC Use.
Refer to description on Serial I/F
20
DIGITAL INDICATOR
DN500N
CENTRONICS PARALLEL OUT (PRINTER I/F)
SET WEIGHING UNIT PRINT
F40
Kg
ton
F41
1
F42
F43
0
1
Remove Subtotal: Press Clear Key and then press SUB Key.
Remove Grand: Press Clear Key and then press Grand Key
Remove Subtotal, Grand automatically once printing is done.
F44
F45
When print output, print 1 line and then adjust the interval to
the next line.
1 Count increase = 1 Line increase
(This will be applied only to consecutive print.)
F46
F47
Korean
English
21
DIGITAL INDICATOR
DN500N
PRINT DELAY TIME
0.0
F48
00
9.9
F52
F77
This is to automatically set the setting value of Function to the initial factory default..
F80
0.10
F81
XXXXXX
F89
1.23456
How to change = (Actual weight value Indicator display value) X F89 Constant =
(100105) X 1.23456 = 1.17577)
Once you change the current F89 constant 1.23456 to 1.17577, the indicator display value will
be shown as 100Kg.
22
DIGITAL INDICATOR
DN500N
CONFIRM & CHANGE DATE (YEAR, MONTH, DATE)
F90
F91
23
DIGITAL INDICATOR
DN500N
7. INTERFACE
7-1. Serial Interface
RS-232C Serial Interface
RS-232C Interface is sensitive to electric noise..
Therefore, please do the wiring separately from the wires of AC Power Cable or other
electric wires and you must use Shield Cable for it.
Communication Mode: You can set on F-Function(F30F35).
Signal Format
Type: EIA-RS-232C
Method: Half-Duplex, asynchronous method, Stream
Baud-rate: 2400,4800,9600,14400,19200,28800,38400,57600,76800,115200 can be selected.
Data bit: 7 or 8(No, Parity)
Stop bit: 1
Parity bit: Even, Odd, No, Parity can be selected
Code: ASCII
+9V
-9V
LSB
Data bit
MSB
Stop bit
Parity bit
Start bit
Data format(1)
Header1
Header2
Data(8)
Header 1
- OL: OVER LOAD, UNDER LOAD
- ST: Display Stable
- US: Display unstable
Header 2
- NT: NET WEIGHT
- GS: GROSS WEIGHT
24
unit
CR
LF
DIGITAL INDICATOR
DN500N
Data on number
- 2B (H): "+"PLUS
- 2D (H): "-"MINUS
- 2O (H): " "SPACE
- 2E (H): "."Decimal point
UNIT
- Kg
Data format(2)
K
Lamp Status
Header1
Header2
Data(8)
CR
Blank
ID NO.
unit
Header 1
- OL: OVER LOAD, UNDER LOAD
- ST: Display Stable
- US: Display Unstable
Header 2
- NT: NET WEIGHT
- GS: GROSS WEIGHT
ID Number: To be set on F33
Lamp Status: Shows current lamps ON and OFF Status
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Stable
Hold
Gross Weight
Tare
Zero
Data on Number
- 2B (H): "+"PLUS
- 2D (H): "-"MINUS
- 2O (H): " "SPACE
- 2E (H): "."Decimal point
UNIT
- Kg
25
LF
DIGITAL INDICATOR
DN500N
Connection to PC (Personal Computer) and other devices
PERSONAL COMPUTER
9 PIN(Standard)
3: TxD
RxD : 2
2: RxD
TxD : 3
5: SG
SG : 5
INDICATOR
RS-232C Circuit
2. RxD
3. TxD
5. SG
26
DIGITAL INDICATOR
DN500N
1
0
20mA
0mA
Data Format
Same as RS232C
Connection to External Display and other devices
Indicator
External Display
1 : RxD
C/L
2 : RxD
C/L
27
DIGITAL INDICATOR
DN500N
SIGNAL FORMAT
TYPE : RS-422
FORMAT: Baud-Rate: 300115200 can be selected.
Data Bit: 7 or 8 (No Parity)
Stop: 1
Parity Bit: Even, Odd, No Parity can be selected.
Code: ASCII
1.5V
Potential
difference
LSB
0
Start 1 bit
Data bit
MSB
6
Parity bit
Stop 1 bit
ID.NO. (2)
Header1 (2)
1.
COMMAND (4)
Header2 (2)
DATA (14)
DATA (8)
Header1
- Stable
- Unstable
- Over Load
2. Header2
- Net Weight
- Net Hold Weight
- Gross Weight
- Gross Hold Weight
3. UNIT
- kg
t
4. DATA
- Weight including sign and decimal point
5. BCC = %(MOD) 127(7FH) ^(XOR) 136(88H)
28
BCC (1)
ETX (1)
UNIT (2)
DIGITAL INDICATOR
DN500N
COMMAND MODE
( READ COMMAND )
TO INDICATOR
STX ID. NO.
RTIM
BCC
COMMAND DESCRIPTION
ETX
RDAT
BCC
ETX
RSNO
BCC
ETX
RCNO
BCC
ETX
RPNO
BCC
ETX
RTAR
BCC
ETX
RCWT
BCC
ETX
RSUB
BCC
ETX
transmit
transmit
to
INDICATOR RESPONSE
Transmit Time DATA(6)
- STX ID.NO. RTIM 000000 BCC ETX
Transmit Date DATA(8)
- STX ID. NO. RDAT 00000000 BCC ETX
Transmit S/N (6)
- STX ID. NO. RSNO 000000 BCC ETX
Transmit Code Number(6)
- STX ID. NO. RCNO 000000 BCC ETX
Transmit P/N(2)
- STX ID. NO. RPNO 00 BCC ETX
Transmit KEY Tare (6)
- STX ID. NO. RTAR 000000 BCC ETX
Transmit currently measured weight
- STX ID. NO. RCWT DATA1 BCC ETX
- STX ID. NO. RSUB P/N(2) CODE_BUF(6)
COUNT(6) S.T.W(8) UNIT
BCC
ETX
No decimal point.
RGRD
BCC
ETX
Command
Total
RFIN
BCC
ETX
Command
to
measuring status
RCWD
BCC
ETX
transmit
STX
ID.NO.
DATA1 (14)
HEADER1 (2)
HEADER2 (2)
DATA2 (52)
DATE (8)
TIME (6)
P/N (2)
CODE
(6)
S/N (6)
TARE (6)
NET.W (8)
Current weight
29
GROSS.W (8)
END
UNIT (2)
DIGITAL INDICATOR
DN500N
COMMAND MODE
( WRITE COMMAND)
TO INDICATOR
COMMAND DESCRIPTION
INDICATOR RESPONSE
STX ID. NO.
WTAR
BCC
ETX
WTRS
BCC
ETX
WZER
BCC
ETX
WPRT
WSPR
WGPR
BCC
BCC
BCC
ETX
ETX
ETX
Command to change
Serial memorized
inside.
30
WTAR ACK
or
WTAR NAK
BCC ETX
BCC ETX
WTRS ACK
or
WTRS NAK
BCC
ETX
BCC
ETX
WZER ACK
or
WZER NAK
BCC
ETX
BCC
ETX
WPRT ACK
or
WPRT NAK
BCC
ETX
BCC
ETX
WSPR ACK
or
WSPR NAK
BCC
ETX
BCC
ETX
WGPR ACK
or
WGPR NAK
BCC
ETX
BCC
ETX
WDAT ACK
or
WDAT NAK
BCC
ETX
BCC
ETX
WTIM WCK
or
WTIM NAK
BCC
ETX
BCC
ETX
WSNO ACK
or
WSNO NAK
BCC
ETX
BCC
ETX
WPNO ACK
or
WPNO NAK
BCC
ETX
BCC
ETX
WCNO ACK
or
WCNO NAK
BCC
ETX
BCC
ETX
DIGITAL INDICATOR
DN500N
STX ID. NO.
STX ID. NO.
WHOL
BCC
ETX
WHRS
BCC
ETX
WSTC
BCC
ETX
WGTC
BCC
ETX
WAUT
BCC
ETX
WMUL
BCC
ETX
WGRO
BCC
ETX
WHOL ACK
or
WHOL NAK
BCC
ETX
BCC
ETX
WHRS ACK
or
WHRS NAK
BCC
ETX
BCC
ETX
WSTC ACK
or
WSTC NAK
BCC
ETX
BCC
ETX
WGTC ACK
or
WGTC NAK
BCC
ETX
BCC
ETX
WAUT ACK
or
WAUT NAK
BCC
ETX
BCC
ETX
WMUL ACK
or
WMUL NAK
BCC
ETX
BCC
ETX
WGRO ACK
or
WGRO NAK
BCC
ETX
BCC
ETX
ACK = Reception Completed (Normal Operation), NAK = Bad Reception (Retry Transmission)
31
DIGITAL INDICATOR
DN500N
Signal
Description
Division
NC
STROBE Signal
Output
RXD
DATA input
Input
TXD
DATA output
Output
NC
GND
GROUND
Output
NC
NC
NC
NC
32
DIGITAL INDICATOR
DN500N
Output Voltage
0~10V DC Output
Accuracy
Over 1/1000
This Voltage Output generates analog voltage (0~10V) compared to the weight display
signal input.
ADJUST (Refer to the details at Page34. )
At dispatch, it is set as 0V with weight display 0 and 10V with maximum load.
It is set accurately when output voltage is measured by DIGITAL MULTI-METER.
Please do the detailed adjustment for VR1 (Zero on Analog out PCB) and VR2 (SPAN) inside
of indicator.
Note: This Analogue out output is printed after converting displayed weight value (Micro
Process DATA) to Analogue value by D/A converter.
The accuracy of D/A converter is below 1/4000. Therefore, users should use the device with
accuracy below 1/3000
This is not suitable for the device that requires high accuracy over 1/3000.
CONNECTOR
EX
If you need 0~5VDC 1~5VDC Output,
please ask us in advance before we dispatch the product.
33
DIGITAL INDICATOR
DN500N
SPECIFICATIONS
Output Current
Accuracy
Over 1/1000
Temperature Coefficient
0.01%
500 MAX.
When weight display is 0, Output current 4 will be made. When weight display is maximum
display capacity, 20 will be made.
This should not connected any other devices GND Line or Body GND or any other similar device
since Lo(-) circuit is not GND.
*Equivalent
Circuit
ADJUST
1. At dispatch, it is set as 4 with weight display 0 and 20 with maximum load.
2.If you dont get accurate output when you measure output current with DIGITAL MULTI-METER,
please do the detailed adjustment on VR(ZERO), VR(SPAN) on Analog Out PCB inside
the indicator.
Note: This Analogue out output is printed after converting displayed weight value
(Micro Process DATA) to Analogue value by D/A converter.
The accuracy of D/A converter is below 1/4000. Therefore, users should use the device
with accuracy below 1/3000
This is not suitable for the device that requires high accuracy over 1/3000.
CONNECTOR
9 Pin D-TYPE Female Connector
1: HI (+)
5: Lo (-)
34
DIGITAL INDICATOR
DN500N
YJ-350 Printer
GND
GND1
RXD
TXD1
TXD
RXD1
- Print Format
Consecutive,
Subtotal,
Total Printing
Consecutive,
Subtotal,
Total Printing
in English
INDICATOR
Individual
Printing
Individual Printing in
English
35