You are on page 1of 2

MEDUMAT Standard2

A clear new perspective


New Features:
CPAP + ASB mode
Volume monitoring
CO2 monitoring, including capnography
Curve display (pressure, flow, CO2)
Pressure-controlled ventilation modes
(PCV, aPCV, BiLevel + ASB, PRVC + ASB)

More options for greater freedom


In the future MEDUMAT Standard2 will offer even better perspectives in flexibility as the number of functions expands.
You then have more options for the individualized customization of your device. Order now or add them later.

Option flow measurement + ASB


Monitoring of expiratory tidal and
minute volumes and respiratory frequency

NE W

Pressure support in CPAP and SIMV modes for


ideal support with Non-Invasive Ventilation

Option curve display


Display of pressure and flow curve
for clear and close monitoring
Prerequisite: The option flow measurement + ASB is installed

NE W

Option capnography
End tidal CO2 displayed as
measurement and as curve
Improved monitoring of ventilation therapy
and assistance with CPR and induction of anesthesia

NE W

CO2 monitoring possible without active ventilation

Option pressure-controlled ventilation modes


Lung-protective ventilation with
PCV, aPCV, BiLevel + ASB and PRVC + ASB modes
Display of pressure and flow curve for
clear and close monitoring
Prerequisite: The option flow measurement + ASB is installed

NE W

MEDUMAT Standard2
A clear new perspective
More functions for emergency medical staff:
Guideline-compliant resuscitation
with help from CPR mode

Reliable monitoring of ventilation


with pressure, volume and CO2 monitoring
complete with curve display

RSI mode assists with induction of


anesthesia in pre-hospital care

Expanded area of application with option


pressure-controlled ventilation modes

Non-Invasive Ventilation by means of


CPAP with pressure support

Options increase flexibility

Faster and simpler ventilation


initiation with entry of patient height
or use of emergency mode

Ventilation and defibrillation in


one hand when combined with
MEDUCORE Standard

Technical Data MEDUMAT Standard2


Device dimensions

W: 206 mm x H: 137 mm x D: 130 mm

Weight, including battery

about 2.5kg

Product class as per


Directive 93/42/EEC:

IIb
-18 C to +50 C
0 % RH to 95 % RH without condensation
540 hPa to 1100 hPa
to 5000 m

Battery:

Operating time:
10 hrs. (depending on options and device)
Charging time (0% - 95%): 3.5 hrs.

Display:

TFT color display

Data storage:

SD card
Volume-controlled:

Ventilation modes:

Pressure-controlled:

Spontaneous:
Operating gas:

Medical-grade oxygen

Operating pressure range:

2.7 bar to 6 bar

Monitoring:

5 inches
IPPV, CPR, RSI, SIMV (with option SIMV),
SIMV + ASB (with option SIMV and option flow measurement + ASB),
S-IPPV (with option S-IPPV), Inhalation (with option inhalation)
PCV (with option pressure-controlled ventilation modes),
aPCV (with option pressure-controlled ventilation modes),
BiLevel + ASB (with option pressure-controlled ventilation modes),
PRVC + ASB (with option pressure-controlled ventilation modes)
CPAP, CPAP + ASB (with option flow measurement + ASB)

Displayed measurements: pPeak, pPlat, pMean, Vte (with option flow measurement + ASB),

MVe (with option flow measurement + ASB),

f (with option flow measurement + ASB),

fsp (with option flow measurement + ASB),

Vleak (with option flow measurement + ASB),
etCO2 (with option capnography)
Curves:
Airway pressure (with option curve display),

Flow (with option curve display),
CO2 (with option capnography)
Manometer:
pressure manometer

Maximum outlet flow:

At least 80 l/min with inlet pressure 4.5 bar in Air Mix and in No Air Mix operation

Respiratory frequency:

5 min-1 to 50 min-1

Inspiratory pressure:

3-60 mbar (with option pressure-controlled ventilation modes)

Pressure support ASB:

0-30 mbar (with option flow measurement + ASB)

Inspiratory trigger:

3 levels (with option flow measurement + ASB)

Tidal volumes:

50 ml to 2000 ml

Pressure limitation (Pmax):

10 mbar to 65 mbar

PEEP:

0 mbar to 20 mbar

Standards used:

EN 60601-1, EN 1789, EN 794-3, ISO 10651-3, RTCA DO-160 G

weinmann-emergency.de | weinmann-emergency.fr | weinmann-emergency.ru | weinmann-emergency.cn

14-405-EN-05/2015 Copyright WEINMANN Emergency, Hamburg. Duplication of any kind only with the express permission of WEINMANN Emergency.
All rights to technical and design modifications are reserved.

Temperature range:
Humidity:
Air pressure:
Altitude above sea level:

Operating conditions:

You might also like