Ariston Led ES
Fault
1
3
2
3
1/2
LED2
LED3
F01
Off
Blinking
Off
F02
On
Blinking
Off
F03
Off
Blinking
On
F04
On
Blinking
On
F05
Blinking
Blinking
On
F06
On
Blinking
Blinking
F07
Off
Blinking
Blinking
F08
Blinking
Blinking
Off
F09
Blinking
Blinking
Blinking
F14
On
Off
On
F16
Off
Off
Off
F20
Blinking
Off
Blinking
Blinking
F21
On
On
F22
Blinking
On
On
F23
Blinking
On
Blinking
F24
Off
On
Blinking
F25
On
Off
Blinking
CAUSE
CORRECTIVE ACTIONS
-
F01
Check for water leaks that may affect connector E1 causing the relative contacts
to short.
Check motor terminal board (possible problems due to incorrect connection
which may cause short-circuits).
Replace motor
Replace PCB.
F02
F03
Replace PCB
F04
F05
F06
F07
Electronic damper does not - Check efficiency of electronic damper connection at foam-protected connector
behind multiflow.
open / close
-
Triac operating defrost heater - Check defrost heater element connections and possible short circuits at the
freezer compartment junction box.
element
-
F08
dance value read is compatible with the value given in the relevant table.
Incorrect switching of solenoid
- Check correct switching of the solenoid valve. With the compressor running, check
valve
-
that the solenoid valve switches when the refrigerator compartment is set to OFF.
Replace solenoid valve.
Replace main PCB.
F09
F14
F16
2/2
Replace PCB.
FAULT
CAUSE
F20
F21
F22
CORRECTIVE ACTIONS
-
F23
F24
F25
COOLING