PAINTS | DEFECTS AND REMEDIES

While painting or some time after the painting, you may notice some defects in the painting.
Understanding the causes of these defects can prepare you well enough, before you start the painting
process and make the job easier. Here are some common paint defects and the solutions to remedy them:
Blistering: Blistering or Swelling of paint is caused due to trapping of air, moisture or solvent between the
surface and the paint film. The remedy is to remove any unstable paint films. Allow the wall to dry
thoroughly, and repaint with a recommended paint. Also, avoid painting under direct sunlight

Bittiness: Bittiness is caused due to dirt from the atmosphere or dirt on the surface or dirt from brushes
that are inadequately cleaned or due to bits of dried-up paint that gets stirred in. The Remedy is to use
clean brushes and paint on a clean surface. Also, strain the paint through a cloth before use.
Algae/Fungus growth: Algae and fungus can grow when the surface is continually damp and dirty.
Insufficient fungicide/ algaecide in the paint can also worsen the situation.The Remedy is to remove algae /
fungus by high-pressure washing. Wash again to remove any residue. Allow the wall to dry before applying
with recommended paint.
Brush marks: Brush marks are caused due to under-thinning of paints or due to poor application of the
final coat of paint or due to poor quality brush. The Remedy is to ensure the paint is applied using the right
viscosity and a good brush.

Chipping: Chipping of paint film is due to excessive use of putty or due to very thick coat of paint or
defective surfaces. The Remedy is to regulate the use of putty and paint.
Chalking: Chalking occurs when ultraviolet rays cause the paint binder to disintegrate. It can happen
when interior paints are used for exterior surfaces. The solution- Remove any unstable paint films. Allow
wall to dry thoroughly, and repaint with recommended paint. Make sure paint is not adulterated with
foreign materials.
Cissing: Cissing or tiny craters are caused by oily or greasy surface or due to water based paints being
applied over gloosy or smooth enamel paints. The Remedy is to clean the surface thoroughly with soap
solution and water. Roughen enamel paint with Sandpaper or use a barrier coat of matt primer.

Cracking: This is caused when the paint or varnish is applied over a base layer of different elasticity
before it has been given enough time to cure (which can take up to a month). For example, two separate
brands of varnish may react with each other and form cracks. The Remedy is to allow the surface to dry
fully and then rub it down to make it ready for repainting. However, you could consider leaving the
cracking visible. It is a very popular ageing technique.
Drips: Drips or nibs in the dried paint surface are usually pure lapses in technique. The Remedy is to rub
the dried drips away with fine sandpaper and re-paint the area. On high gloss finishes you may need to
apply a final coat over the entire area to disguise the patch where you rubbed.
Efflorescence: Efforescence or formation of white powdery deposit on walls after painting is caused due
to salts present in the building material like brick and mortar, which surface later on. The Remedy is to
give a long time gap between plastering and painting (about 6 months including one monsoon) Use paint
with a porous film like emulsions and distempers.

Fat edges: A heavy ridge of paint along the edges is caused by too much paint on the brush. The Remedy
is to tap the paint brush against the container for the excess paint to drain out.
Grinning: If the previous colour shows through the finishing coat, it is because the base was too dark or
the paint was too thin or badly applied. The Remedy is to just paint over.
Loss of gloss: Loss of gloss is caused due to poor surface preparation or due to presence of oil or due to
over thinning of paint. The Remedy is to clean the surface thoroughly and take all recommended steps for
surface preparation.
Discolouration: After paint is applied, it may fade or discolour. This is caused by particles in the wall
reacting with the paint when it is drying. Discolouration could also be caused by water seepage, or by
contaminants in metal or wood. The Remedy is to repair water seepage. Make sure the surface is dry
before painting. And apply an alkaline-resistant or oil-based paint.
Flaking: Flaking-off of paint film is due to improper application of primer coat over putty, and not being
completely covered. It can also be due to application of paint on insufficiently dry surfaces or due to
shrinkage or expansion of a surface causing the paint film to move. The Remedy is to ensure that there are
no gaps in covering putty with primer coat. Also ensure that the surface is dry and clean.

Patchiness: Patchiness or uneven finish is caused due to the highly absorbent nature of the surface. The
Remedy is to apply an extra coat of primer or use well-sealer.
Peeling: Peeling is caused by moisture on the wall, poor surface preparation or using the incorrect
painting system. This defect happens on walls as well as wood or metal surfaces.
The remedy for walls is to check and repair water seepage. Ensure the walls are dry before painting. And
use an alkali-resistant basecoat or sealer. Patch surface defects with putty.
The remedy for wood is to prime wood before painting, sand the surface and clean off dust.
The remedy for metal is to remove all paint from metal before re-painting. Prime the surface and re-coat
with suitable paint.
Sagging: Sagging happens when the paint droops downward after being applied on the surface. It is
caused by the pigment separating from the paint and settling at the bottom of the container and comes as
a result of insufficient stirring or shaking during storage, storing for too long or under too much heat, or
faulty thinning. The Remedy is to avoid storing in hot locations for long periods. Store in accordance with
the manufacturer's recommendations and thin only with appropriate recommended thinners.
Wrinkling: Wrinkling happens when the paint forms film-like undulating waves. Applying too much paint,
or drying during high temperatures, or painting on a topcoat before the undercoat is dry can cause this
defect. The Remedy is to avoid applying too much paint. Make sure no paint accumulates round bolts,
rivets, etc. Wait until each coat dries before you re-coat.
Slow drying: Non-drying or slow drying of paint film is caused due to humidity, poor air circulation, low
temperature or presence of oil or grease on the surface or due to alkalinity of the surface. The Remedy is
to reduce the impact of atmospheric conditions to the extent possible; Scrub oil or grease off with a rag
soaked in white spirit and wash with water and soap.

Sheariness: Patches of uneven sheen on flat- or low-sheen finishes are caused


by painting on too porous a surface, causing uneven drying. The Remedy is to use a large brush or roller to
cover
the
area
quickly
or
a
sealer
undercoat.
Yellowing: White paint will gradually yellow because it receives little light - such as inside cupboards or
behind pictures. The Remedy is to use non-yellowing whites

PREMIUM ACRYLIC WATER BASED PAINT


1. BOYSEN Clear Acrylic Emulsion #700

DESCRIPTION: BOYSEN Clear Gloss Acrylic Emulsion is an acrylic type transparent coating that acts as a
barrier against dampness on concrete walls.
PRINCIPAL USES: Improves performance of latex paint applied on humid and/or damp environments.
PRACTICAL COVERAGE: 20-25 square meter / 4 liters / coat
SURFACE DRY: Thirty (30) minutes
DRY THROUGH: Two (2) hours
DRY FILM THICKNESS: 1-1.5 mils /coat
OVERCOATING INTERVAL: Allow one hour before recoating.
THINNING: Use as supplied. If necessary, thin with not more than 1/2 liter of water per 4-liter can
APPLICATION: paint brush, roller or airless spray.
PACKAGING: 4-liter cans
SURFACE PREPARATION:
New Masonry:
Allow new masonry to dry 14 to 28 days under normal weather conditions before painting. Surfaces to be
painted should be clean and dry, free from oil, grease, dust, dirt contaminants, and all loose grit and
mortar. Treat new masonry with a solution of 1 part BOYSEN Masonry Neutralizer #44 diluted in 16 parts
water, applying liberally by brush or roller. Let dry overnight before rinsing with water to remove white
crystals that form on the surface. Let dry before painting.
PAINTING SCHEDULE:
1st Coat: BOYSEN Permacoat Flat Latex #701
2nd Coat: BOYSEN Clear Gloss Acrylic Emulsion #700
Topcoat: BOYSEN Permacoat Latex (flat, semi-gloss, gloss)

2. DESCRIPTION: BOYSEN Latex Colors are concentrated acrylic based tinting paints for

BOYSENPermacoat Latex Paints, BOYSEN Healthy Home, and BOYSEN Wallguard


Dirt Resisting Latex. They disperse easily and produce tints from pastel to medium shades
with even finishes.

PACKAGING: 1 liter and 1/4 liter cans


NOTE: To produce dark shades, choose from factory mixed colors, Mix-and-Match outlets, or
intermix premixed colors to get desired shade. Ideal ratio of tinting color to paint is 1:16,
respectively. Do not use Hansa Yellow B1466 and Toluidine Red B1407 for exterior
applications.
AVAILABLE COLORS:
B1404 Thalo Blue
B1405 Thalo Green
B1406 Raw Sienna
B1407 Toluidine Red
B1408 Burnt Sienna
B1409 Burnt Umber
B1466 Hansa Yellow

B1477 Venetian Red


B1490 Lampblack

3. DESCRIPTION: BOYSEN Masonry Putty #7311 is a water based product especially prepared for
filling minor surface unevenness while using latex paint systems. Can also be used for full puttying.
PRINCIPAL USES: For interior concrete, stucco, bricks plaster or any surface minor imperfection.
PRACTICAL COVERAGE:
Full Putty - 10-12 square meter / 4 liters / coat
Spot putty - 25 square meter / 4 liters / coat
SURFACE DRY: Thirty (30) minutes
DRY THROUGH: Two (2) hours
OVERCOATING INTERVAL: Allow two hours before recoating
THINNING: Use as supplied.
APPLICATION: putty knife
PACKAGING: 16-liter, 4-liter and 1-liter cans

4. DESCRIPTION: BOYSEN Permacoat Latex Paint is a 100% acrylic latex paint with excellent
hiding, durability and dirt pick-up resistance. It finishes painting jobs in less coats, yet lasts longer
than other brands allowing you to save a lot on time, effort, worry and money.
PRINCIPAL USES: For interior and exterior such as concrete, stucco, bricks plaster, hollow blocks,
drywall surfaces, and properly primed wood.
PRACTICAL COVERAGE: 25-30 square meter / 4 liters / coat
SURFACE DRY: Thirty (30) minutes
DRY THROUGH: Two (2) hours
DRY FILM THICKNESS: 1-1.5 mils/coat
OVERCOATING INTERVAL: Allow one hour before recoating.
THINNING: Use as supplied. If necessary, thin with not more than liter of water per 4-liter can
APPLICATION: paint brush, roller or airless spray.
PACKAGING: 16-liter; 4-liter and 1-liter cans (white only)
AVAILABLE COLORS:
B701 White
B702 Off White
B721 Cream
B723 Moonlight
B725 Bone Ivory
B771 Tile Red

B780 Chocolate Brown


COLORANTS: Use only BOYSEN Latex Colors for tinting to achieve pastel shades. To produce dark
shades, use factory or Mix and Match pre-mixed colors. Do not use Hansa Yellow B-1466 and Toluidine
Red B1407 for exterior applications.
SURFACE PREPARATION:
Please refer to CHOOSE YOUR PAINT section for specifics.
PAINTING SCHEDULE:
1st Coat: BOYSEN Permacoat Flat Latex #701
Putty:
BOYSEN Masonry Putty #7311 (interior use)
BOYSEN Acrytex Cast #1711 (exterior use)
2nd & 3rd Coat:

BOYSEN Permacoat Flat Latex (any desired color)

5. DESCRIPTION: BOYSEN Permatex #3101 is a water-based, full-bodied paint that dries to a fine
rubbery coating, creating a beautiful textured finish on interior walls and ceilings bringing elegance
to your home interior. It adheres easily on wood, masonry, and drywall surfaces. Conceals hairline
cracks and minor surface imperfections, and dries to a fine rubbery coating that does not become
brittle, leaving virtually no room for cracking, chipping, or peeling off.
PRINCIPAL USES: For interior wood, drywall, and masonry surfaces.
PRACTICAL COVERAGE: 5 - 6 square meter / 4 liters
SURFACE DRY: Two (2) hours
DRY THROUGH: Overnight
OVERCOATING INTERVAL: Two (2) hours
THINNING: Use as supplied. If necessary, thin with not more than 1/2 liter of water per 4 liter can
PACKAGING: 4-liter cans
APPLICATION:
For a regular texture pattern, apply BOYSENPermatex #3101 straight from the can using a
regular textured roller. If a different design is desired, first apply BOYSEN Permatex #3101 with a
regular textured roller immediately followed by the desired pattern roller while the paint is still wet
and workable. Roll in one uniform direction to impress the design onto the surface.
PAINTING SCHEDULE:
Wood:
1st Coat:
Putty:
Texture:
2nd & 3rd coat:

BOYSEN Flatwall Enamel #800


BOYSEN Plasolux Glazing Putty #311
BOYSEN Permatex #3101
BOYSEN Permacoat Latex (any desired color)

Masonry & Drywall:


1st Coat:
BOYSEN Permacoat Flat Latex #701
Putty:
BOYSEN Masonry Putty #7311
Texture:
BOYSEN Permatex #3101
2nd & 3rd coat:
BOYSEN Permacoat Latex (any desired color)

6. DESCRIPTION: BOYSEN Plexibond is a specially formulated acrylic polymer designed for


compounding with Pozzolan or Portland cement. The resulting mixture possesses excellent
adhesion, water resistance and flexibility even on thin section applications. Its use eliminates any
cement plastering defects and water seepage, making it ideal for waterproofing roof decks and
firewalls. It makes for a durable and decorative cementitious coating that not only enhances the
appearance of light building materials but also prolongs their service life as well with its excellent
weatherability. It offers excellent corrosion resistance when applied on metal surfaces, and can also
be used to improve adhesion to mortar patching and tile grouts.
PRINCIPAL USES: Excellent adhesion to concrete, bricks, wood and good corrosion resistance on
metal surfaces such as G.I. sheets.
FEATURES AND BENEFITS:
Outstanding flexibility - A thin section of ordinary cement is hard and brittle and crumbles easily,
while cement modified with BOYSEN Plexibond possesses superior flexibility, thus eliminating
cement plastering defects. The excellent adhesive and tensile strength balance of
BOYSEN Plexibond maintains the integrity of the mortar.
Excellent Water Resistance - When mixed with cement, BOYSEN Plexibond forms a seamless,
non-porous impenetrable thick layer that disperses any liquid upon contact, preventing any water
seepage when applied on both vertical and horizontal surfaces.
Resistant to Weathering - BOYSEN Plexibond has excellent sunlight exposure resistance,
prolonging the service life of light building materials such as marine plywood and cement asbestos
boards.
Solvent-free - BOYSEN Plexibond uses water for film cure, and thus has low odor, low
flammability or other hazards inherent for solvent based systems.
Retards Fire Spread - BOYSEN Plexibond is non-flammable, and retards flame spread when used
as a cementitious coating for light building materials such as plywood.
Excellent Corrosion Resistance - BOYSENPlexibond offers good corrosion resistance on metal
surfaces such as G.I. sheets when applied at a minimum thickness of 20 mils.
Beautifies - BOYSEN Plexibond can be brushed on as a plaster finish or applied by textured roller
or mortar gun, giving an attractive orange peel textured cementitious coating. The thin
cementitious coating allows the preservation of architectural detail on wood, masonry, and metal
surfaces.
PRACTICAL COVERAGE: 5 - 6 square meter / 4 liters
SURFACE DRY: One (1) hour
DRY THROUGH: One (1) hour
DRY FILM THICKNESS: Approximately 20 mils
OVERCOATING INTERVAL: Allow overnight before applying paint
THINNING: Not necessary
PACKAGING: 4-liter can
SURFACE PREPARATION:
BOYSEN PLEXIBOND should be applied on bare concrete, wood, or metal NOT PREVIOUSLY PAINTED.
Existing paint should be totally scraped off. New masonry should be allowed to cure at least 14 to 28

days. Surface should be clean, free from oil, grease, dirt, any loose grit or mortar. Wet masonry
surfaces first with water before applying BOYSEN Plexibond mix to avoid abrupt drying and cracking
of the applied modified cement, especially under hot and sunny conditions.
APPLICATION:
Mix 6.5 to 7.5 kgs. of cement to 4 liters of BOYSEN Plexibond. Add cement to BOYSEN Plexibond
slowly while stirring to prevent lumping. Pass mixture through a fine strainer to sift out lumpy
materials. Ensure intimate mixing, stirring as often as possible to avoid settling. Keep mixture
proportion constant for a uniform texture. Mix only enough material to prevent waste. Workability of
BOYSEN Plexibond mixture is 30 minutes, while potlife is 2 hours.
For vertical surfaces such as firewalls, apply two coats of Plexibond mixture by textured roller (for
orange peel texture finish) or three coats by brush (for plain finish) while maintaining coverage rate at
5-6 sq. meters per gallon. Recoating interval is 1-2 hours.
For horizontal surfaces such as roof decks, parapets, canopies and ledges, apply five coats by brush or
three coats by textured roller.
Reinforce joints, corners and active cracks susceptible to cracking or movement with a strip of
fiberglass matting. Put on the matting immediately after the second coat, while the mixture is still wet.
The matting should adhere to the mixture. Make sure the Plexibond coating and the matting is
completely dry before applying succeeding coats. The matting should be completely covered by the
mixture. Let dry for one day, then apply a bond coat by brushing BOYSEN Plexibond straight from
the can prior to laying out mortar topping.
For filling large cracks, add 3 parts by volume of fine uniform-sized sand to 1 part cement and mix with
BOYSENPlexibond to trowellable consistency.
For maximum durability, topcoat application is recommended. Suggested topcoats are
BOYSEN Permacoat Latex, BOYSEN Acrytex, BOYSEN Acqua Epoxy or BOYSEN Epoxy Enamel.
Allow BOYSEN Plexibond to dry at least one day before paint application.

7. DESCRIPTION: BOYSEN Primeguard is a water-based acrylic maintenance primer designed to


have excellent adhesion and metal passivation. BOYSEN Primeguard is used where superior
protection and good adhesion on hard-to-adhere metal surfaces is desired. It eliminates the need
for a vinyl butyral wash primer tie coat.
PRINCIPAL USES: For galvanized iron, stainless steel, aluminum and other metal works such as
iron and steel frame.
FEATURES AND BENEFITS:
Exceptional adhesion - as BOYSEN Primeguard has exceptional adhesion even on stainless steel
and aluminum. It is also an environment-friendly alternative to traditional butyral wash primers.
Corrosion Resistance- It passivates the metal substrate to provide good corrosion resistance on
carbon steel.
Rapid Drying - dries in 20-30 minutes, compared to 8 hours for enamel primers. Recoat interval is 2
to 4 hours, resulting in faster paint jobs and significant labor cost savings.
Thermoplastic Nature - Remains flexible over time. It does not pose problems of intercoat adhesion
and is capable of being topcoated by most solvent-based home coatings.
Environmentally Safe - It has low odor, is non-flammable, and does not use hazardous solvents. It
does not contain lead and is non-toxic compared to traditonal anti-corrosive primers.
Easy Water Cleanup - no need for thinners and solvent reducers. Tools and painting equipment,
spills and paint drips while still wet can be cleaned by water and soap solutions.

PRACTICAL COVERAGE: 30 - 40 square meter /4-liters / coat


SURFACE DRY: Thirty (30) minutes
DRY THROUGH: Two (2) hours
DRY FILM THICKNESS: 1.5 mils/coat
OVERCOATING INTERVAL: Allow 2-4 hours before recoating.
THINNING: Water if necessary
APPLICATION: By brush, airless spray or roller.
PACKAGING: 4-liter cans
AVAILABLE COLORS:
B4310 Primeguard Red Oxide
B4301 Primeguard White
B4320 Primeguard Gray
SURFACE PREPARATION:
Metal - Wipe the surface with rag soaked in paint thinner to remove dust, dirt, grease, oil, wax and
other foreign matter. If repainting, wire brush or scrape rusted metals and apply BOYSEN Metal
Etching Solution #71 to remove all rust. Let it stay for 10-15 minutes. Be sure to wash off surface
thoroughly with water, letting it dry before applying paint. Primer should be applied immediately
after drying.
PAINTING SCHEDULE:
New Metal:
1st coat: BOYSEN Primeguard
2nd & 3rd coat: BOYSEN Cool Shades, BOYSEN Roofgard, BOYSEN Acqua Epoxy,
BOYSEN Epoxy Enamel (for interior surface only), BOYSEN Acrytex, BOYSEN Quick Drying
Enamel
Repainting:
It can be applied over old alkyd paint that is in good condition. Surface preparation prior to painting
must be followed. It can be topcoated as in "new metal."

8. DESCRIPTION: BOYSEN Roofgard is a gloss acrylic, water-based roof paint designed to


protect and adhere to most roof substrates. It gives a durable and flexible film, fast-drying
time and good gloss retention.
PRINCIPAL USES: For galvanized iron surfaces, pre-painted galvanized sheets, asphalt
shingles, and unglazed roof tiles.
PRACTICAL COVERAGE: 25-30 square meter / 4 liters / coat
SURFACE DRY: Thirty (30) minutes
DRY THROUGH: Two (2) hours
DRY FILM THICKNESS: 1.5 mils/coat
OVERCOATING INTERVAL: Two (2) hours
THINNING: Maximum 1/2 liter water per 4 liters paint

APPLICATION: by brush, roller or spray. Clean equipment with soap and water after use
PACKAGING: 4-liter and 16-liter cans
AVAILABLE COLORS:
B2501 Laguna White
B2520 Samar Beige
B2540 Pacific Blue
B2550 Baguio Green
B2560 Orient Gold
B2570 Spanish Red
B2573 Terra Cotta
B2580 Chocolate Brown
COLORANTS: Use BOYSEN Latex Colors for tinting to achieve pastel shades. To obtain
darker colors, intermix standard colors or request for a factory mix color.
SURFACE PREPARATION:
For unpainted galvanized iron sheets, etch the surface by applying 10% BOYSEN Metal Etching
Solution #71 (dilute 1 part of B-71 to 9 parts water). Wipe the surface with rag soaked in
BOYSEN Paint Thinner #0340 to remove grease. Rinse with water and let dry.
For prepainted galvanized iron sheets, scuff sand surface using sandpaper and wipe the surface
with clean rag before applying paint. Spot prime if necessary.
For corroded G.I. surface, remove rust by wire brushing and use BOYSEN Metal Etching Solution
#71. Let it stay for 10-15 minutes. Be sure to wash off surface thoroughly with water or paint
thinner and let dry. Apply primer a few hours after application of B-71 and before rust sets in.
For new unglazed rooftiles, make sure surfaces are completely clean and dry.
PAINTING SCHEDULE:
Primer for:
Galvanized Iron Sheets
BOYSEN Red Oxide #310, BOYSEN Rust Off Primer Gray #330,
or BOYSEN Primeguard #4310
Unglazed tiles:
BOYSEN Acrytex Primer #1705
Topcoat:
BOYSEN Roofgard (2-3 coats; any desired color)
Repainting:
For G.I. sheets with paint in good condition, clean surface of dirt and dust by washing and apply
two coats of BOYSEN Roofgard.
Introducing a new breed of latex paints that has a very high resistance to dirt, dust, smog and mildew. It
can be painted even in a rigorous environment where there is a very high concentration of airborne
pollutants.
9. DESCRIPTION: BOYSEN Wallguard Dirt Resisting Latex #5715 is suitable to be used near industrial
areas and along highways. It is specially suited for repainting medium and high-rise building where the
need to maintain a freshly painted look with less maintenance is of prime importance.

Highly Resistant to airborne pollutants and dust


100% Acrylic
Highly alkaline resistant
Resist fading, cracking and peeling
Good exterior durability
Excellent gloss retention
Mildew resistant
Good block and scrub resistance
PRINCIPAL USES: Use BOYSEN Wallguard as an exterior finish for newly constructed building as well as
repainting old structures.
PRACTICAL COVERAGE: 25 - 30 square meter / 4 liters /coat
SURFACE DRY: Thirty (30) minutes
DRY FILM THICKNESS: 1.5 mils /coat
OVERCOATING INTERVAL: Allow one hour before recoating.
THINNING: Use as supplied. If necessary, thin with not more than liter of water per 4-liter can
APPLICATION: paint brush, roller or airless spray
PACKAGING: 4-liter cans
AVAILABILITY: Semi-Gloss #5715
COLORANTS: Use only BOYSEN Latex Colors for tinting to achieve pastel shades. To produce dark
shades, use factory mixed colors.

SURFACE PREPARATION:
New Masonry:
Allow new masonry to dry for 14 to 28 days under normal weather conditions before painting. Surface to
be painted should be clean and dry, free from oil, grease, dust, dirt, contaminants, and all loose grit and
mortar. Treat new masonry with a solution of 1 part BOYSEN Masonry Neutralizer #44 diluted in 16 parts
water, applying liberally by brush or roller. Let dry overnight before rinsing with water to remove white
crystals that form on the surface. Let dry before painting.
Repainting:
Remove all loose, scaling, flaking and peeling off paint using BOYSEN Paint and Varnish Remover #141,
wire brushing, scraping, or water blasting. Let it dry. Sand smooth painted surfaces for improved adhesion.
In case of mildew infestation, treat with BOYSEN Fungicidal Wash Solution #74 or bleach solution (1:3,
laundry bleach to water, respectively) by swabbing or brushing. To ensure proper treatment, allow to
stand on surface for overnight before washing off residue. Let dry.
PAINTING SCHEDULE:

New Painting:
1st coat: BOYSEN Acrytex Primer #1705
Putty: BOYSEN Acrytex Cast #1711
2nd & 3rd coat: BOYSEN Wallguard Dirt Resisting Latex
Repainting:
Topcoat: Apply two coats of BOYSEN Wallguard Dirt Resisting Latex on properly prepared

surface.

SPECIAL WATER BASED COATINGS


1. DESCRIPTION: BOYSEN Cool Shades is a heat reflective colored roof coating that is waterbased & has low VOC. It utilizes the technology of infrared-reflecting pigments that repel infrared
light before it turns into heat. To maintain the heat reflective effect over time, Cool Shades is
designed with an all-acrylic binder that provides excellent dirt pick up resistance.

HOW IT WORKS:

Infrared Reflective Pigments

BOYSEN Cool Shades is designed with highly engineered infrared-reflecting (IR) pigments making it
possible to create greens, blues, yellows, grays, and other shades of roof coating while reflecting infrared
light and reducing heat build up. A paint film containing infrared-reflecting pigments will stay cooler than
one containing non-reflective pigments of the same color. The ability of a colored object to reflect infrared
light can be quantified through Total Solar Reflectance (TSR).

Cool Shades

Non-Reflective
Roof Coating

Total Solar Reflectance


(the higher the better)

67

53

Coolshades can
reflect 21% more
infrared light

Dirt Pick-up resistance The ability of IR pigments to reflect infrared light is affected by how long does
the paint film stays clean. BOYSEN Cool Shades all-acrylic technology is designed to keep the film
durable and dirt pick-up resistant.

Cool Shades

Non-Reflective
Roof Coating

L* value upon painting

83.23

83.22

L* value after dirt exposure

65.90

50.57

Dirt Pick-up resistance

80%

61%

PRINCIPAL USES: Roof coating that provides cooling effect and energy savings.

PRACTICAL COVERAGE: 25-30 sq.m./4-Liter/coat.

SURFACE DRY: Thirty (30) minutes.

RECOAT TIME: Two (2) hours; seven (7) days to fully cure.

COLORS:
B8520 Radiant Beige
B8501 Shady Gray
B8500 Reflecting White
B8547 Polarize Blue
B8550 Spring Green
B8573 Vibrant Terra Cotta
B8580 Zen Brown

SHEEN: Gloss

VOC: <100 g/L

APPLICATION: Brush, Spray

THINNING: Use as supplied. If necessary, thin with not more than Liter clean water per 4-Li can.

SURFACE PREPARATION:

For optimum cooling effect,use water-based white metal primer.

PAINTING SCHEDULE:
New Painting
Clean surfaces to be painted to be free of dirt, dust, grease and oil and other contaminants.
Primer : BOYSEN Primeguard White #4301
Topcoat : BOYSEN Cool Shades (2 coats) of desired color.
Repainting
Remove rust by sanding, scraping or wirebrushing. Treat rusted surfaces with BOYSEN Metal
Etching Solution #71 (rust converter) to completely remove rust. Wipe of treated areas with paint
thinner to remove excess rust converter.
Primer : BOYSEN Primeguard White #4301
Topcoat : BOYSEN Cool Shades (2 coats) of desired color.

2. BOYSEN EcoPRIMER #105 is an eco-friendly acrylic water-based primer used for masonry
and drywall surfaces. This ultra-low volatile organic compound (VOC) formulation is designed to
have superior alkali resistance, excellent adhesion and sealing properties ideal for interior and
exterior application.
PRACTICAL COVERAGE: 25-30 square meter / 4 liters / coat.

SURFACE DRY: Thirty (30) minutes.


DRY

THROUGH: Two

(2)

hours.

DRY FILM THICKNESS: 1-1.5 mils/coat.


OVERCOATING INTERVAL: Allow one hour before recoating.
THINNING: Use as supplied.
APPLICATION: paint brush, roller or airless spray.
PACKAGING: 4-liter cans.
SURFACE PREPARATION:
New Masonry:
Allow new masonry to dry for 14 to 28 days under normal weather conditions before painting. Surface
to be painted should be clean and dry, free from oil, grease, dust, dirt, contaminants, and all loose grit
and mortar. Treat new masonry with a solution of 1 part BOYSEN Masonry Neutralizer #44 diluted in
16 parts water, applying liberally by brush or roller. Let dry overnight before rinsing with water to
remove white crystals that form on the surface. Let dry before painting.
Repainting:
Remove all loose, scaling, flaking and peeling off paint using BOYSEN Paint and Varnish Remover
#141, wire brushing, scraping, or water blasting. Let it dry. Sand smooth painted surfaces for improved
adhesion. Apply 1 coat of BOYSEN Chalk Blocker for chalking old paint. In case of mildew infestation,
treat with a fungicidal wash solution or bleach solution (1:3, laundry bleach to water, respectively) by
swabbing or brushing. To ensure proper treatment, allow to stand on surface for overnight before
washing off residue. Let dry.

PAINTING SCHEDULE:
BOYSEN EcoPRIMER #105
BOYSEN Acrytex Cast #1711 (for exterior);
BOYSEN Masonry Putty #7311 (for interior)
2nd & 3rd Coat:
BOYSEN Healthy Home (for interior)
Virtuoso Silk Touch (for interior)
BOYSEN KNOxOUT Air Cleaning Paint #8701 Acrylic Water-based
BOYSEN KNOxOUT Air Cleaning Paint #8702 Silicon-based
1st Coat:
Putty:

3. BOYSEN Healthy Home is a odor-less, low VOC, premium acrylic, water-based interior coating
with exclusive Microban antibacterial protection to give extra defense against bacteria such as
E. coli and Salmonella, as well as mildew and fungus.
DESCRIPTION: BOYSEN Healthy Home dries to a durable satin finish that makes it ideal for walls
and ceilings in bedrooms, kitchens, bathrooms, as well as damp and humid areas where an added level
of protection against microbes is desired. Microban technology is incorporated into the paint at the
manufacturing stage and does not wash or wear off for the duration of the paints service life.
PRINCIPAL USES: BOYSEN Healthy Home is the ideal choice for residences, medical facilities,
nursing homes, schools, day care facilities, and food commissaries. For interior concrete and drywall
surfaces.

PRACTICAL COVERAGE: 25-30 square meter / 4 liters / coat


SURFACE DRY: Thirty (30) minutes
DRY THROUGH: Two (2) hours
DRY FILM THICKNESS: 1-1.5 mils/coat
OVERCOATING INTERVAL: Allow one hour before recoating.
THINNING: Use as supplied.
APPLICATION: paint brush, roller or airless spray
PACKAGING: 4-liter cans
COLORANTS: Use only factory or Mix-and-Match pre-mixed colors.
AVAILABLE COLORS:
B7410 Hygienic White
B7420 Light Tan
B7430 Clean Slate
B7440 Serene Lake
B7442 Fresh Air
B7450 Flora
B7460 Shining Ochre
B7470 Bloom
B7472 Rosy
* Also available in B7415 Semi-Gloss Hygienic White
SURFACE PREPARATION:
New Masonry:
Allow new masonry to dry 14 to 28 days under normal weather conditions before painting. Surfaces to be
painted should be clean and dry, free from oil, grease, dust, dirt contaminants, and all loose grit and
mortar. Treat new masonry with a solution of 1 part BOYSEN Masonry Neutralizer #44 diluted in 16 parts
water, applying liberally by brush or roller. Let dry overnight before rinsing with water to remove white
crystals that form on the surface. Let dry before painting.
Repainting:
Remove all loose, scaling, flaking and peeling off paint using BOYSEN Paint and Varnish Remover #141,
wire brushing, scraping, or water blasting. Let dry. For chalking old paint, use BOYSEN Chalk Blocker
#7304 as primer. In case of mildew infestation, treat with fungicidal wash solution or bleach solution (1:3,
laundry bleach to water, respectively) by swabbing or brushing. To ensure proper treatment, allow to
stand on surface for overnight before washing off residue. Let dry.
PAINTING SCHEDULE:
Concrete
1st Coat: BOYSEN Permacoat Flat Latex #701
Putty: BOYSEN Masonry Putty #7311
2nd & 3rd Coat: BOYSEN Healthy Home
Drywall Surfaces
1st Coat: BOYSEN Permacoat Flat Latex #701
Putty: BOYSEN Gypsum Joint Compound #711

2nd & 3rd Coat: BOYSEN Healthy Home


Visit the Healthy Home paint website for more information.
4. DESCRIPTION: BOYSEN KNOxOUT is the first air cleaning paint in the world with CristalActiv
photocatalytic technology. It uses light energy to break down noxious air pollutants and convert
them into harmless substances. Any surface coated with KNOxOUT becomes an active airpurifying surface that helps protect people from harmful gases. Photocatalysis also provides
KNOxOUT with self-cleaning, anti-bacterial and de-odorizing properties.
PRACTICAL USE: BOYSEN KNOxOUT will be of benefit in areas with high NOx levels, such as indoor
car parks and outdoor houses and buildings in urban areas.
TYPICAL PROPERTIES:
Variants: B8701 Acrylic or B8702 Silicon
Finish: Flat

Specific Gravity : 1.42-1.52


Solid By volume : 30-35
Solid By weight : 52-55

Dry time

Touch dry : 20-30 minutes


Hard dry : 2-3 hours
Recoat : 2-3 hours

Theoretical Coverage: 25-30 sq. meter/4 liters/ one coat


Wet film Thickness: 110-120 microns
Dry Film Thickness: 40-45 microns
Visit the KNOxOUT paint website for more information.
APPLICATION METHOD:
Tools: Brush, Roller, Airless Spray
APPLICATION SYSTEM:
SURFACE PREPARATION:
New Masonry:
Allow new masonry to dry for 14 to 28 days under normal weather conditions before painting. Surface to
be painted should be clean and dry, free from oil, grease, dust, dirt, contaminants, and all loose grit and
mortar. Treat new masonry with a solution of 1 part BOYSEN Masonry Neutralizer #44 diluted in 16 parts
water, applying liberally by brush or roller. Let dry overnight before rinsing with water to remove white
crystals that form on the surface. Let dry before painting.
Repainting:
Remove all loose, scaling, flaking and peeling off paint using BOYSEN Paint and Varnish Remover #141,
wire brushing, scraping, or water blasting. Let it dry. Sand smooth painted surfaces for improved adhesion.
Apply 1 coat of BOYSEN Chalk Blocker for chalking old paint. In case of mildew infestation, treat with
fungicidal wash solution or bleach solution (1:3, laundry bleach to water, respectively) by swabbing or

brushing. To ensure proper treatment, allow to stand on surface for overnight before washing off residue.
Let dry.

Apply 1 coat B-105 BOYSEN Ecoprimer


Putty minor surface imperfections with BOYSEN Masonry Putty #7311 for interior masonry and
BOYSENAcrytex Cast #1711 for exterior masonry. Spot prime puttied areas.
Apply 2 coats B8701- BOYSEN KNOxOUT Air Cleaning Paint Acrylic or B8702BOYSEN KNOxOUT Air Cleaning Paint Silicon
5. Hudson Timber Coat Polyurethane Water-based Wood Coating is a one component waterborne
non-yellowing urethane coating ideal for finishes on wood and parquet floors. It combines
excellent hardness and flexibility, high abrasion resistance and high gloss appearance. It resists
ordinary household detergents, acids and alkalis, sauces, food spills and beverages. Gives mild
odor.
USE:
Excellent on wooden floor parquets used for residences, condominiums, offices and townhouses. For
interior and exterior wood such as furniture, fixtures, cabinets, doors, moldings, jambs and panels.
APPLICATION: brush or spray
RECOATING INTERVAL: 1 hour
THINNING: Not necessary
CLEAN UP: Application tools should be cleaned with water.
STABILITY:1-year shelf-life in unopened container properly stored container.
PACKAGING: 3.5 liter
COVERAGE: 20-30 square meters / coat / 3.5 liters
AVAILABILITY: Matte, Semi-gloss, Gloss

SURFACE PREPARATION:
New Wood:
1. Use only kiln dried wood.
2. Countersink nail heads for putty application.
3. Sand rough wood until smooth, then dust off before painting.
4. Surface to be painted should be clean and dry, free from dust, dirt and other foreign matter.
Old Wood:
1. Remove loose paint to sound surface.
2. Scuff sand intact film to provide anchorage for succeeding coats.
3. If old coating is oil-based, scrape all existing paint to bare surface.
4. Surface to be painted should be clean and dry, free from dust, dirt and other foreign matter.
FINISH APPLICATION:
1. Shake Hudson Timber Coat Polyurethane Water-based Wood Coating for 15 to 20 seconds and
let sit for 5 to 10 minutes.
2. Apply first coat. First coat acts as a sealer for new wood surfaces. Let dry for an hour.
3. Sand and apply another coat.
4. Sand after an hour. Apply two more coats.

5. Allow 48 hours drying time for areas with light traffic and at least seven (7) days for normal to
heavy traffic areas.

6. Virtuoso Silk Touch is a breakthrough product that incorporates Teflon surface protector
technology to create a paint formula that uniquely combines the visual elegance of flat paints
with the easy clean capabilities of gloss paints.
DESCRIPTION: Virtuoso Silk Touch is a 100% acrylic water-based paint that is low odor, low
VOC, lead free, and has outstanding color retention. It dries to a luxurious silk finish that not only
imparts a sense of warmth and depth to your living space but is also distinctively smooth to touch.
With Teflon surface protector, oil and dirt cannot easily stick to your walls, making it easy to wipe
off common everyday stains.
PRINCIPAL USES: Virtuoso Silk Touch is best for areas in need of stain resistant walls. For
interior concrete and drywall substrates.
PRACTICAL COVERAGE: 25-30 square meter / 4 liters / coat
SURFACE DRY: Thirty (30) minutes
DRY THROUGH: Two (2) hours
DRY FILM THICKNESS: 1-1.5 mils/coat
OVERCOATING INTERVAL: Allow one hour before recoating.
THINNING: Use as supplied.
APPLICATION: paint brush, roller or airless spray.
PACKAGING: 4-liter cans
COLORANTS: Use only factory or Mix-and-Match pre-mixed colors
AVAILABLE COLORS:
V9000C76 Passion
V9000C05 Fragrant White
V9000C22 Roasted Honey
V9000C03 Baileys White
V9000C43 Cool Breeze
V9000C02 Cotton
V9000C54 Pistachio
V9000C04 Hint of Mint
SURFACE PREPARATION:
Please refer to CHOOSE YOUR PAINT section for specifics.
PAINTING SCHEDULE:
Concrete
1st Coat: BOYSEN Permacoat Flat Latex #701
Putty: BOYSEN Masonry Putty #7311
2nd & 3rd Coat: Virtuoso Silk Touch

Drywall Surfaces
1st Coat: BOYSEN Permacoat Flat Latex #701
Putty: BOYSEN Gypsum Joint Compound #711
2nd & 3rd Coat: Virtuoso Silk Touch
Visit the Virtuoso Silk Touch paint website for more information.
ALKYD ENAMEL/OIL BASED COATINGS
1. DESCRIPTION: BOYSEN Alkyd Traffic Paint is an alkyd-based paint for traffic
markings/linings. It must be applied on epoxy-primed asphalt and rough concrete.
PRINCIPAL USES: It is designed for use on street markings, curbs, traffic lanes and safety
zone lining.
PRACTICAL COVERAGE: 20-25 sq. m/ gal / coat
SURFACE DRY: 30 minutes
DRY THROUGH: 1 hour
OVERCOATING INTERVAL: 1 hour
THINNING: BOYSEN Paint Thinner #0340 if needed
APPLICATION: By brush, roller
PACKAGING: 4-liter cans
AVAILABLE COLORS:
BOYSEN Alkyd Traffic Paint #1901 White
BOYSEN Alkyd Traffic Paint #1961 Yellow.

2. DESCRIPTION: BOYSEN Bridge and Tank Aluminum Paint # 85 is a highly reflective grade
of aluminum paint ideal for storage tanks and structural steel, since it tends to keep these
cooler.
PRINCIPAL USES: For storage tanks, structural steel and other industrial metal surfaces.
PRACTICAL COVERAGE: 20-25 square meter / 4 liters / coat
SURFACE DRY: 2-4 hours
DRY THROUGH: Overnight
DRY FILM THICKNESS: 1.5 mils
OVERCOATING INTERVAL: Allow 24 hours before recoating
THINNING: Not necessary
APPLICATION: By brush

PACKAGING: 4-liter cans


SURFACE PREPARATION:
Metals:
Wipe the surface with rag soaked in paint thinner to remove dust, dirt, grease, oil, wax and other

foreign matter. For new G.I. sheets, etch the surface by applying 10% BOYSEN Metal Etching
Solution #71 (dilute 1 part of B-71 to 9 parts water).

If repainting, wire brush or scrape rusted metals and apply BOYSEN Metal Etching Solution #71.
Let it stay for 10-15 minutes. Be sure to wash off surface thoroughly with water or paint thinner,
letting it dry before applying paint. Primer should be applied immediately after treatment to prevent
flash rusting.
PAINTING SCHEDULE:

1st coat: BOYSEN Red Oxide Primer #310, BOYSEN Rust Off Primer Gray #330, or
BOYSEN Primeguard #4310

2nd and 3rd coat: BOYSEN Bridge and Tank Aluminum Paint # 85

3. DESCRIPTION: BOYSEN Flat Wall Enamel #800 is a flat alkyd type paint that provides great
durability while being noted as a fast drying paint. It is formulated to give a tough and durable film. It
is also used as a primer for enamel coatings.
PRINCIPAL USES: For interior and exterior wood surfaces.
PRACTICAL COVERAGE: 20 - 25 square meter / 4 liters / coat
DRY FILM THICKNESS: 1.5 mils/coat
SURFACE DRY: Thirty (30) minutes
DRY THROUGH: Eight (8) hours
OVERCOATING INTERVAL: Allow six (6) hours before recoat
THINNING: Use BOYSEN Paint Thinner #0340
APPLICATION: By brush or roller
PACKAGING: 16-liter, 4-liter and 1-liter can
COLORANTS: Use only BOYSEN Oil Tinting Colors for tinting to achieve pastel shades. To produce
dark shades, use factory mixed color. Do not use Prussian Blue B-2304, Hansa Yellow B-2319, and
Bulletin Red B-2315 for exterior application.
SURFACE PREPARATION:
Surface to be painted should be clean and dry, free from dust, dirt and other foreign matter.
Hammer all nails deep enough to apply putty. Sand rough wood until smooth, then dust off before
painting.
If repainting, first remove all blistering, peeling and scaling paint by wire brushing or BOYSEN Paint
and Varnish Remover #141. Clean surfaces thoroughly before painting.
PAINTING SCHEDULE:
1st Coat: BOYSEN Flatwall Enamel #800
Putty: BOYSEN Plasolux Glazing Putty #311
2nd & 3rd Coat: BOYSEN Flatwall Enamel #800

4. DESCRIPTION: BOYSEN Heat Resisting Aluminum #95 is formulated for surfaces subject to heat
with peak temperature of 800 F or 427 C.
PRINCIPAL USES: For metal surfaces of equipment, radiators and machinery.
PRACTICAL COVERAGE: 20 square meter / 4 liters / coat
DRY THROUGH: Will dry when peak temperature is reached.
DRY FILM THICKNESS: 1.5-2 mils
OVERCOATING INTERVAL: Allow overnight before recoating
APPLICATION: by brush
THINNING: not necessary
PACKAGING: 4 liter cans
SURFACE PREPARATION:
Metal:
Wipe the surface with rag soaked in lacquer thinner to remove dust, dirt, grease, oil, wax and other foreign
matter.
For rusted portions, wire brush or scrape loose rust and apply BOYSEN Metal Etching Solution #71. Let it
stay for 10-15 minutes. Be sure to wash off surface thoroughly with water or paint thinner, letting it dry
before applying paint. Product should be applied immediately after treatment to prevent flash rusting.
PAINTING SCHEDULE:
Apply 2 to 3 coats of BOYSEN Heat Resisting Aluminum #95 on bare substrate.

DESCRIPTION: Boysen Oil Tinting Colors are concentrated alkyd based tinting paints for oil, alkyd and
enamel paints. They are used to produce tints from pastel to medium shades.
PACKAGING: 1/4 liter cans
NOTE: To produce dark shades, choose from factory mixed colors or intermix premixed colors to get
desired shade. Ideal tinting color-to-paint ratio is 1:16, respectively.
AVAILABLE COLORS:
B2313 Burnt Sienna
B2303 Thalo Green
B2314 Raw Sienna
B2304 Prussian Blue*
B2315 Bulletin Red*
B2306 Thalo Blue
B2317 Venetian Red
B2307 French Yellow Ochre
B2318 Lampblack
B2319 Hansa Yellow*
B2311 Burnt Umber
* Interior use only
5. DESCRIPTION: BOYSEN Plasolux Glazing Putty #311 is an alkyd-type product specially prepared
for filling minor surface unevenness on enamel-painted wood.
PRINCIPAL USES: For filling minor surface dents and imperfections on wood.

PRACTICAL COVERAGE:
Full Putty - 10-12 square meter / 4 liters / coat
Spot putty - 25 square meter / 4 liters / coat
SURFACE DRY: 4-5 hours
DRY THROUGH: Overnight
OVERCOATING INTERVAL: Allow two hours before recoating
THINNING: BOYSEN Paint Thinner #0340 if necessary
APPLICATION: putty knife

PACKAGING: 4-liter and 1-liter cans


PAINTING SCHEDULE:
1st Coat: BOYSEN Flatwall Enamel White #800
Putty: BOYSEN Plasolux Glazing Putty #311
2nd & 3rd coat: BOYSEN Quick Drying Enamel (any desired color),
BOYSEN Semi-Gloss Enamel #200, or BOYSEN Flatwall Enamel White #800
7. DESCRIPTION: BOYSEN Quick Drying Enamel is an alkyd type paint that provides great
durability while being noted as a fast drying paint. It is formulated to give a tough, durable,
beautiful and high build film on wood and metal. Its superior hiding, combined with an
exceptionally high gloss level, leads to an excellent, long-lasting finished appearance.
PRINCIPAL USES: Superior for exterior and interior wood and metal surfaces.
PRACTICAL COVERAGE: 20 - 25 square meter /4 liters /coat
DRY FILM THICKNESS: 1.5 mils/coat
SURFACE DRY: Five (5) hours maximum
DRY THROUGH: Two (2) hours
OVERCOATING INTERVAL: Allow eight (8) hours
THINNING: Use BOYSEN Paint Thinner #0340 if necessary
APPLICATION: By brush or roller
PACKAGING: 16-liter (white only), 4-liter, 1-liter and -liter can
AVAILABLE COLORS:
B600 White
B621 Ivory
B630 Silver Gray
B632 Medium Gray
B640 Royal Blue
B642 Sky Blue
B647 Delft Blue
B650 Nile Green
B651 Dark Green
B656 Jade Green
B658 Emerald Green
B661 Lemon Yellow
B665 Caterpillar Yellow

B691
B690
B685
B681
B680
B676
B673
B671
B670
B683

Flat Black
Black
Sammy Brown (Analux Yellowish)
Mahogany
Chocolate Brown
Orange
Maroon
International Red
Bright Red
Caramel Brown

8. COLORANTS: Use only BOYSEN Oil Tinting Colors for tinting to achieve pastel shades. To
produce dark shades, use factory mixed color. Do not use Prussian Blue B-2304, Hansa Yellow
2319, and Bulletin Red B-2315 for exterior application.

B-

SURFACE PREPARATION:
Wood - Surface to be painted should be clean and dry, free from dust, dirt and other foreign matter.
Hammer all nails deep enough to apply putty. Sand rough wood until smooth, then dust off before
painting.
If repainting, first remove all blistering, peeling and scaling paint by wire brushing or BOYSEN Paint
and Varnish Remover #141. Clean thoroughly prior to painting.
Metal - Wipe the surface with rag soaked in paint thinner to remove dust, dirt, grease, oil, wax and
other foreign matter. For new G.I. sheets, etch the surface by applying 10% BOYSEN Metal Etching
Solution #71 (dilute 1 part of B-71 to 9 parts water).
If repainting, wire brush or scrape rusted metals and apply BOYSEN Metal Etching Solution #71 to
remove all rust. Let it stay for 10-15 minutes. Be sure to wash off surface thoroughly with water,
letting it dry before applying paint. Prime immediately after drying.
PAINTING SCHEDULE:
WOOD
1st Coat:
BOYSEN Flatwall Enamel #800
Putty:
BOYSEN Plasolux Glazing Putty #311
2nd & 3rd Coat:
BOYSEN Quick Dry Enamel (any desired color)
METAL
1st coat:
2nd & 3rd Coat:

BOYSEN Red Oxide Primer #310,


BOYSEN Rust Off Primer Gray #330,
or BOYSEN Primeguard #4310
BOYSEN Quick Dry Enamel (any desired color)

6. DESCRIPTION: BOYSEN Red Oxide Primer #310 is a rust inhibiting primer for steel and iron
surfaces. It is particularly good for metal shops who deliver metal products coated with a shop
primer to protect them from rust corrosion until such time as they are finished with desired
topcoat.
PRINCIPAL USES: As a primer for exterior and interior steel.
PRACTICAL COVERAGE: 25 - 30 square meter /4 liters /coat
DRY FILM THICKNESS: 1.5 mils/coat
SURFACE DRY: Two hours
DRY THROUGH: 5-6 hours

OVERCOATING INTERVAL: 8 hours to overnight


THINNING: Use BOYSEN Paint Thinner #0340 if necessary
APPLICATION: By brush, roller or conventional spray
PACKAGING: 16-liter, 4-liter and 1-liter can
SURFACE PREPARATION:
Wipe the metal surface with rag soaked in paint thinner to remove dust, dirt, grease, oil, wax and other
foreign matter. For new G.I. sheets, etch the surface by applying 10% BOYSEN Metal Etching Solution #71
(dilute 1 part of B-71 to 9 parts water).
If repainting, wire brush or scrape rusted metals and apply BOYSEN Metal Etching Solution #71 to remove
all rust. Let it stay for 10-15 minutes. Be sure to wash off surface thoroughly with water, letting it dry
before applying paint. Prime immediately after drying.
PAINTING SCHEDULE:
1st Coat: BOYSEN Metal Primer Red Oxide #310
2nd & 3rd Coat: BOYSEN Quick Dry Enamel (any desired color)
7. BDESCRIPTION: BOYSEN Reflectorized Traffic Paint is an alkyd-type paint specially developed
to resist the rigorous environment encountered on highways, roads, pavements, and parking lots.
It forms a durable film that offers good wear resistance and better reflective beads retention for
safety markings.
PRINCIPAL USES: A reflectorized variant to the alkyd-based traffic paint for use on road
markings and pavement linings. To be used only on areas in direct contact to wheel traffic
otherwise the reflectorized-effect will not manifest.
PRACTICAL COVERAGE: 20 square meter / 4 liters / coat
SURFACE DRY: 10 minutes
DRY THROUGH: 30 minutes
OVERCOATING INTERVAL: 30 minutes
THINNING: BOYSEN Paint Thinner #0340 if necessary
APPLICATION: By brush
PACKAGING: 4-liter cans
AVAILABLE COLORS:
BOYSEN Reflectorized Traffic Paint #19-101 White
BOYSEN Reflectorized Traffic Paint #19-161 Yellow
BOYSEN Rust-Off Gray Alkyd Metal Primer #330 is a lead and chromate free, high rust inhibiting primer
for interior/exterior steel and iron surfaces.
FEATURES:
Safe & environment friendly formulated without lead, mercury or chromates.
Excellent corrosion resistance formulated with special rust inhibiting pigments that are even more
corrosion resistant than traditional lead and chromate pigments.
Excellent adhesion strong penetration into metal surfaces provides outstanding adhesion that gives
long term protection.
Excellent hiding quality light gray shade offers optimal hiding for white and other colored topcoats.

PRINCIPAL USES:
Rust inhibitive primer or intermediate coat for maintenance of interior/ exterior architectural metal or
structural steel (beams, doors, framing, railings, machinery).
PRACTICAL COVERAGE: 25 - 30 sq.m. / 4 liters / coat
DRY FILM THICKNESS:1.5 mils / coat
SURFACE DRY: Two (2) hours
DRY THROUGH: 5-6 hours
OVERCOATING INTERVAL: 8 hours to overnight
THINNING: Use BOYSEN Paint Thinner #0340 if necessary
APPLICATION: By brush, roller or conventional spray
PACKAGING:16-liter, 4-liter and 1-liter can

SURFACE PREPARATION:
Wipe the metal surface with a rag soaked in paint thinner to remove dust, dirt, grease, oil, wax and other
foreign matter. For new G.I. sheets, etch the surface by applying 10% BOYSENMetal Etching Solution #71
(dilute 1 part of B-71 to 9 parts water). If repainting, wire brush or scrape rusted metals and apply
BOYSEN Metal Etching Solution #71 to remove all rust. Let it stay for 10-15 minutes. Be sure to wash off
surface thoroughly with water, letting it dry before applying paint. Prime immediately after drying.
PAINTING SCHEDULE:
1st Coat: BOYSEN Rust-Off Gray Alkyd Metal Primer #330
2nd & 3rd coat: BOYSEN Roofgard, BOYSEN Cool Shades, BOYSEN Acqua Epoxy, BOYSEN Epoxy
Enamel (for interior surface only), BOYSEN Acrytex, BOYSEN Quick Drying Enamel
Repainting:
It can be applied over old alkyd paint that is in good condition. Surface preparation prior to painting must
be followed. It can be topcoated as in "new metal.