DESIGN OF FOOTING

Size of footings L = B =
S.B.C. Of soil

3.45

mtrs.

10

T/sq.mtr

Working load on column =

102

Tons

Self wt. Of footings P

16.36594 Tons

Total load (W) =

118.3659 Tons

Max. Press. Under footings =

9.944628 T/sq.mtrs < S.B.C (

Net. Press. Under footing

8.569628 T/sq.mtrs

Maximum over hang

Maximum B.M.

11.31459 T-mtrs./mtr

Ultimate

16.97188 T-mtrs/mtr

Mu/(b*d^2)

B.M.
=

1.625

Area of steel provided

col.size :

b =
d =

mms.
200
800

Depth of footing =

550

effective depth

494

10

mtrs.

0.695466 N/sq.mm

Area of steel required

F1

Pt = 0.182697

902.5223 sq.mm./mtr.

=
=

1017

sq.mm./mtr

CHECK FOR PUNCHING SHEAR :


Pt(provided) =

0.20587 %

Fck = 35

Vc = 0.396176 N/sq.mm

check for punching @ av = 0 ( i.e. Along periphery )


perimeter
Actual shear stress

Pr =

2000

Vu =

Allowable shear stress Vc =

mms.

1.548583 N/sq.mm
4.732864 N/sq.mm

check for punching @ av = d/2


perimeter
Actual shear stress

Pr =
Vu =

Allowable shear stress Vc =


( after enhancement)

3976

mms.

0.778965 N/sq.mm
1.188527 N/sq.mm

p.t.o.

F1
check for punching @ av = d
perimeter
Actual shear stress

Pr =
Vu =

Allowable shear stress Vc =


( after enhancement)

5952

mms.

0.520357 N/sq.mm
0.594263 N/sq.mm

check for punching @ av = 1.5 X d


perimeter Pr =
Actual shear stress

Vu =

Allowable shear stress Vc =

7928

mms.

0.390662 N/sq.mm
0.396176 N/sq.mm

DESIGN OF FOOTING
Size of footings L = B =

mtrs.

S.B.C. Of soil

10

T/sq.mtr

Working load on column =

76.87

Tons

Self wt. Of footings P

10.8

Tons

Total load (W) =

87.67

Tons

Max. Press. Under footings =

9.741111 T/sq.mtrs < S.B.C (

Net. Press. Under footing

8.541111 T/sq.mtrs

Maximum over hang

Maximum B.M.

8.370289 T-mtrs./mtr

Ultimate

12.55543 T-mtrs/mtr

Mu/(b*d^2)

B.M.
=

1.4

Area of steel provided

col.size :

b =
d =

mms.
200
600

Depth of footing =

480

effective depth

424

10

mtrs.

0.698393 N/sq.mm

Area of steel required

F2

Pt = 0.183488

777.9901 sq.mm./mtr.

1017

sq.mm./mtr

CHECK FOR PUNCHING SHEAR :


Pt(provided) =

0.239858 %

Fck = 35

Vc = 0.433088 N/sq.mm

check for punching @ av = 0 ( i.e. Along periphery )


perimeter
Actual shear stress

Pr =

1600

Vu =

Allowable shear stress Vc =

mms.

1.699661 N/sq.mm
4.732864 N/sq.mm

check for punching @ av = d/2


perimeter
Actual shear stress

Pr =
Vu =

Allowable shear stress Vc =


( after enhancement)

3296

mms.

0.825078 N/sq.mm
1.299264 N/sq.mm

p.t.o.

F2
check for punching @ av = d
perimeter
Actual shear stress

Pr =
Vu =

Allowable shear stress Vc =


( after enhancement)

4992

mms.

0.544763 N/sq.mm
0.649632 N/sq.mm

check for punching @ av = 1.5 X d


perimeter Pr =
Actual shear stress

Vu =

Allowable shear stress Vc =

6688

mms.

0.406617 N/sq.mm
0.433088 N/sq.mm

DESIGN OF FOOTING
Size of footings L = B =

2.7

mtrs.

S.B.C. Of soil

10

T/sq.mtr

Working load on column =

64.27

Tons

Self wt. Of footings P

7.6545

Tons

Total load (W) =

9.866187 T/sq.mtrs < S.B.C (

Net. Press. Under footing

8.816187 T/sq.mtrs

Maximum over hang

Maximum B.M.

6.887646 T-mtrs./mtr

Ultimate

10.33147 T-mtrs/mtr

Mu/(b*d^2)

1.25

Area of steel provided

b =
d =

mms.
200
600

Depth of footing =

420

effective depth

364

10

mtrs.

0.779757 N/sq.mm

Area of steel required

col.size :

71.9245 Tons

Max. Press. Under footings =

B.M.

F3

Pt = 0.205568

748.2691 sq.mm./mtr.

904

sq.mm./mtr

CHECK FOR PUNCHING SHEAR :


Pt(provided) =

0.248352 %

Fck = 35

Vc = 0.455171 N/sq.mm

check for punching @ av = 0 ( i.e. Along periphery )


perimeter
Actual shear stress

Pr =

1600

Vu =

Allowable shear stress Vc =

mms.

1.655306 N/sq.mm
4.732864 N/sq.mm

check for punching @ av = d/2


perimeter
Actual shear stress

Pr =
Vu =

Allowable shear stress Vc =


( after enhancement)

3056

mms.

0.866652 N/sq.mm
1.365513 N/sq.mm

p.t.o.

F3
check for punching @ av = d
perimeter
Actual shear stress

Pr =
Vu =

Allowable shear stress Vc =


( after enhancement)

4512

mms.

0.586988 N/sq.mm
0.682757 N/sq.mm

check for punching @ av = 1.5 X d


perimeter Pr =
Actual shear stress

Vu =

Allowable shear stress Vc =

5968

mms.

0.443782 N/sq.mm
0.455171 N/sq.mm

DESIGN OF FOOTING
Size of footings L = B =

2.1

mtrs.

S.B.C. Of soil

10

T/sq.mtr

Working load on column =


Self wt. Of footings P

39.27

3.85875 Tons

Total load (W) =

43.12875 Tons

Max. Press. Under footings =

9.779762 T/sq.mtrs < S.B.C (

Net. Press. Under footing

8.904762 T/sq.mtrs

Maximum over hang

Maximum B.M.

4.018274 T-mtrs./mtr

Ultimate

6.027411 T-mtrs/mtr

Mu/(b*d^2)

B.M.
=

mms.
200
400

Depth of footing =

350

effective depth

294

10

Pt = 0.1832

538.6073 sq.mm./mtr.

Area of steel provided

b =
d =

mtrs.

0.697326 N/sq.mm

Area of steel required

col.size :

Tons

0.95

F4

678

sq.mm./mtr

CHECK FOR PUNCHING SHEAR :


Pt(provided) =

0.230612 %

Fck = 35

Vc = 0.468431 N/sq.mm

check for punching @ av = 0 ( i.e. Along periphery )


perimeter
Actual shear stress

Pr =

1200

Vu =

Allowable shear stress Vc =

mms.

1.669643 N/sq.mm
4.732864 N/sq.mm

check for punching @ av = d/2


perimeter
Actual shear stress

Pr =
Vu =

Allowable shear stress Vc =


( after enhancement)

2376

mms.

0.843254 N/sq.mm
1.405293 N/sq.mm

p.t.o.

F4
check for punching @ av = d
perimeter
Actual shear stress

Pr =
Vu =

Allowable shear stress Vc =


( after enhancement)

3552

mms.

0.564069 N/sq.mm
0.702647 N/sq.mm

check for punching @ av = 1.5 X d


perimeter Pr =
Actual shear stress

Vu =

Allowable shear stress Vc =

4728

mms.

0.423767 N/sq.mm
0.468431 N/sq.mm