You are on page 1of 11

Release Notes

June 2015

Analyzer Update

1 In this version
This release contains support for new and updated file formats. There are updates for most
technologies that Actix supports, with changes falling under the following categories:

New collection devices and improvements:

Added support for TEMS Investigation 17, TEMS Symphony 7.6, and TEMS Pocket 15.

Added support for Rohde and Schwarz version 4.85.

Added support for JDSU version 19.0.2.

Added support for DataPro version 1.5.26.

Improved speed of loading TEMS files by 15-25%.

Added support for Video Streaming in TEMS file format.

Added Support for PCTel MXflex scanner device in DataPro file format.

Added support for SeeGull Ex Flex Scanner in Huawei Probe Genex file format.

Improved the RTP event detection engine.

Improvements in support of 3G scanner attributes: multi-UARFCNs and Nth best


sorted by RSCP.

Application Layer

New Stateform for Scanner-Handset comparison.

Platform improvements:

Added the ability to sort columns in the Statistics Explorer.

Added tooltips for column headers in the Table that are not wide enough to display the
name of the column.

Fixed an issue where the Event Diagram Viewer would not display all transitions.

Fixed an issue where the Network Explorer would sometimes not display the elements
correctly in the right-hand side of the window.

Fixed an issue when using 64-bit Analyzer with 32-bit Excel, where user-defined
reports would sometimes have [1] in their file name, which could cause problems
with embedded macros.

Known issues / obsolescence:

Actix Analyzer Update

TEMS Investigation .log files are no longer supported.

June 2015

2 New collection device or technology support


2.1 Ascom TEMS support

Added support TEMS API Route Reader 11.0, which added support for TEMS Investigation
version 17, TEMS Symphony 7.6, and TEMS Pocket 15.
An issue has been fixed that caused Analyzer to crash while loading TEMS version 16 log
files.
Several improvements in TEMS performances (loading and processing) have been added in
this release, which together result in loading being 15-25% faster.
Added support for Video Streaming in TEMS file format.
A problem has been resolved that prevented Analyzer from loading a large number of
small TEMS Automatic log files.
An issue has been fixed that prevented Analyzer from setting relevant GPS attributes.
An issue has been fixed that prevented Analyzer from setting the attribute
Uu_DownlinkUARFCN in specific TEMS log files.
A problem has been resolved that prevented Analyzer from loading specific Indoor TEMS
Pocket version 14.4 log files.

2.2 DataPro support

Added support for version 1.5.26 for DataPro file format.

Added Support for PCTel MXflex scanner device in DataPro file format.

2.3 Huawei Probe support

Added support for SeeGull Ex Flex Scanner (UMTS and LTE scanners) in Genex version 3.6
file format.
An issue has been fixed that caused Analyzer to set an incorrect value of the attribute
Ping_Sent_Count".

2.4 JDSU support

Added support for JDSU version 19.0.2 file format.


An issue has been fixed that caused Analyzer to set incorrect timestamps in the Protocol
Stack Browser.

Actix Analyzer Update

June 2015

2.5 Nemo support

An issue has been fixed that prevented Analyzer from loading Nemo Handy version 2.14
log files.
In GSM, a problem has been resolved that prevented Analyzer from processing all the
frequency bands included in GSM scanner logfiles.
In LTE, improvements have been added to the calculation of the Resource Blocks Allocated
in DL. The attributes involved are:
LTE_UE_RB_Num_DL
LTE_UE_RB_Num_DL_for_Carrier_0
LTE_UE_RB_Num_DL_for_Carrier_1

An issue has been fixed that cause Analyzer to ignore the Marker file due to the presence
of GPS data in the main log file.
In LTE, an issue has been fixed that caused Analyzer to set the same value of Cell ID (in 5
digit format) for two different cells with different PCIs. The attribute involved was:
LTE_Scan_EARFCN_xxxx_GlobalCellId_for_PCI_xxx

A problem has been resolved that prevented Analyzer from plotting attributes on the Map
for Indoor Nemo files with side Marker files.
An issue has been fixed that prevented Analyzer from setting the
attribute LTE_UE_Ant_Num_eNB in the case of Nemo version 2.22 log files.
An issue has been fixed that prevented Analyzer from loading some Nemo version 2.21
logfiles.

2.6 Qualcomm support

A problem has been resolved that prevented Analyzer from setting the attribute
LTE_UE_TB_Size_Average_DL_for_Carrier.
An issue has been identified that prevented Analyzer from setting relevant LTE attributes.

Improvement added to the support of the attribute LTE_UE_VoLTE_Num_Packets_Lost


derived from the Qualcomm IMS RTP Packet message.

Added support for the new Qualcomm-specific attribute QC_LTE_UE_SNR to indicate the
average Signal-to-Noise ratio measured by the UE.

In SRVCC, added a new attribute LTE_SRVCC_Interruption_Time, calculated as the time


difference between LTE_Event_SRVCC_HO_toUMTS_Init to
LTE_Event_SRVCC_HO_toUMTS_OK attributes, which indicates the time taken to execute a
Handover from LTE to UMTS/GSM network.

An issue has been fixed that caused Analyzer to set incorrect values of the
attribute ServMsTxPowerActual (GSM UE Transmit Power).

Actix Analyzer Update

June 2015

2.7 Rohde and Schwarz support

Added support for Rohde and Schwarz version 4.85 file format.
An issue has been fixed that prevented Analyzer from decoding GPS data in some Rohde
and Schwarz version 4.83 log files.
A problem has been resolved that prevented Analyzer from setting relevant Internet
(IP/TCP) attributes in some Rohde and Schwarz version 4.79 log files.
An issue has been fixed that prevented Analyzer from correctly handling a large number of
frequencies in GSM scanner log files.

2.8 Swissqual support

An issue has been fixed that prevented Analyzer from loading large Swissqual log files.
Improvements in performances in terms of loading time have been made in case of large
Swissqual logfiles (.mf > 300MB).
Added support for the Capacity task in the list of possible Task Application types. All the
relevant Task-related attributes are also set accordingly.
A problem has been resolved that prevented Analyzer from setting the attribute
ServRxLevSub and other GSM attributes from GSM layer 3 measurement report
messages.
In MIMO, an issue has been fixed that prevented Analyzer from setting the attributes
listed below for each antenna port:
LTE_UE_RSRP_Ant
LTE_UE_RSRQ_Ant
LTE_UE_RSSI_Ant

In VoLTE, an issue has been fixed that caused Analyzer to set incorrect values for the
attributes LTE_UE_VOLTE_Call_SetupTime and LTE_UE_VOLTE_Call_Duration.
An issue has been fixed that prevented Analyzer from displaying GSM messages in the
Protocol Stack Browser.

2.9 Generic

Several improvements have been added to this release for the RTP event detection engine.
o

Out-of-sequence DL RTP packets are now detected and are treated as successfully
received if the delay is less than a configurable threshold.

New event for out of sequence DT RTP packets, new attribute for the delay.

An issue has been fixed that caused Analyzer to map the value of the RSRP in the
Measurement Report message to the wrong range of values.
Added support for the attribute LTE_Uu_RRC_MeasIdToRemoveList extracted from the RRC
Reconfiguration message.

Actix Analyzer Update

June 2015

In UMTS and GSM, added a new thresholds (Uu_CallDropped_Use_of_CauseLocationCC


for UMTS and G_CallDropped_Use_of_CauseLocationCC for GSM) to detect a drop in
case of CauseLocationCC information element (in the CC Disconnect message) is
different from zero (0=disconnected by the user).
In SRVCC, improvements in the event detection engine have been added in case of a Hand
Over from LTE to GSM and LTE to UMTS.
In VoLTE, improvements have been added in the support of the attributes
LTE_UE_VoLTE_Call_SetupTime and LTE_UE_VoLTE_Call_Duration.
Replaced CINR in the name of the scanner attributes with the more suitable acronym
SINR.
An issue has been fixed that caused Analyzer to decode incorrectly the GSM classmark3
information element.
An issue has been fixed with the GSM L3 Container in the Mobility from EUTRA
Command message that prevented the event detection engine from pegging handovers
events to GSM.
In VoLTE, added support for the new attribute SIP_Registration_Latency to indicate
the time difference between SIP Registration message and its successful response
(SIP_Event=200 OK).
In UMTS Scanner, added support for the node All UARFCN Top N by EcIo in order to
plot 3G scanner attributes for all the frequencies (UARFCNs) logged across the logfile and
sorted by EcIo. New attributes set are:
UMTS_Scan_UARFCN_SortedBy_EcIo
UMTS_Scan_UARFCN_SC_SortedBy_EcIo
UMTS_Scan_UARFCN_RSCP_SortedBy_ EcIo
UMTS_Scan_UARFCN_EcIo_SortedBy_ EcIo

In UMTS Scanner, added new attributes under the node Nth Best in order to plot 3G
Scanner attributes sorted by RSCP. New attributes set are:
CPICH_Scan_EcIo_SortedBy_RSCP
CPICH_Scan_Drift_SortedBy_RSCP
CPICH_Scan_SC_SortedBy_RSCP
CPICH_Scan_RSCP_SortedBy_RSCP

Actix Analyzer Update

June 2015

3 Application layer improvements


3.1 Stateform

For LTE, this release adds a new Stateform (LTE Scanner-Handset comparison) for the
comparison of radio parameters (RSRP, RSRQ) between Scanner and Handset data. The
stateform requires scanner and handset streams to be initially super-streamed in order
to visualize scanner and handset data simultaneously in the stateform.

Actix Analyzer Update

June 2015

4 Platform improvements
4.1 Analysis Manager

Fixed an issue when a query initially created in the Analyzer environment is then edited
and re-imported into Analyzer, carrying the prefix Copy of in the original query name.

4.2 Chart

A crash has been fixed when the Chart would try to display a tooltip for a data point but
the Format Group did not contain the relevant text.

4.3 Event Diagram Viewer

Fixed an issue where the Event Diagram Viewer would not display all transitions.

4.4 Network Explorer

Fixed an issue where the Network Explorer would sometimes not display the elements
correctly in the right-hand side of the window.

4.5 Reporting

Fixed an issue when using 64-bit Analyzer with 32-bit Excel, where user-defined reports
would sometimes have [1] in their file name, which could cause problems with
embedded macros.

4.6 Statistics Explorer

Added the ability to sort columns in the Statistics Explorer.

4.7 Table

Added tooltips for column headers in the Table that are not wide enough to display the
name of the column.

4.8 Other

Fixed an issue where it was not possible to dock dockable windows within one another.

Actix Analyzer Update

June 2015

Fixed an issue that caused Analyzer to crash when, after importing Data Service
Analysis Side Panel.aqf query using Analysis Manager, a user attempts to plot the
query results in Statistic Explorer.

5 Documentation
5.1 Attribute Help

Minor changes in the Attribute Help for the attributes TCP_ThroughputUL and
TCP_ThroughputDL.

Minor changes in the Attribute Help for the attributes LTE_UE_CA_Configured.

6 Known Issues / Obsolescence

TEMS Investigation logfiles with the extension .log (from version 13.x and older) can no
longer be loaded in Analyzer.
If you revert to a previous release of Analyzer after this release is installed, TEMS API 11
causes a conflict between temporary configuration files that will stop TEMS files from
loading. To allow TEMS files to load, delete all files in the following directory:
C:\Users\username\AppData\Local\Temp\Any\8.0.0.0
assuming the Windows OS is installed on the C drive, and the current user is username.

Actix Analyzer Update

June 2015

The content of this manual is provided for information only, is subject to change without notice, and
should not be construed as a commitment by Actix. Actix assumes no responsibility or liability for any
errors or inaccuracies that appear in this documentation.
The product is protected under national and international copyright, trademark and trade secret,
patent and other intellectual property laws and treaties. The product is covered by at least one or
more of the following U.S. patents:8,364,141; 7,653,395; 8,032,131; 7,941,136; 8,150,417;
7,881,319; 7,830,812; 7,904,080; 7,839,846; 7,062,264; 7,349,692; 7,224,968; 7,792,032;
7,634,267; 7,353,160; 8,428,171; 7,877,095; 7,768,968; 8,855,675; Sweden Patent: 524414; Great
Britain Patents: 2,461,242; 2,467,474; 2,196,050; 1,759,549; 1,716,668; 1,678,972; 2,382,502;
2,384,663; 2,404,314; 1,606,965; Australia Patent: 2003301796; Patents registered in China P.R.:
1,934,882; ZL200480007621.7; CN1817056; Patents registered with the European Patent Office:
EP1604278; EP1559289; French Patents: 2,196,050; 1,759,549; 1,716,668; 1,678,972; 1,468,542;
1,606,965; German Patents: 2,196,050; 1,759,549; 1,716,668; 1,678,972; 1,468,542;
102004002145; 103 07 408; 102 51 993.5; 101 04 926; Holland Patent: 2,196,050; India Patent:
1130/CHENP/2005; Italian Patent: 2,196,050; Patents registered in Japan: 4,499,746; 4,452,710;
JP549116/2004; JP5139462; Patents registered in Korea: 10-11-21435; 10-09-39132; New Zealand
Patent: NZ540378; Patents registered in Spain: 2,196,050;1,606,965; and pending patents.
Copyright Actix 2015. All rights reserved. All trademarks are hereby acknowledged.

Actix Analyzer Update

June 2015

10

US:

T +1 703 707 4777


F +1 703 707 4778

AE

T +971 (0) 44461403


F +971 (0) 4495406

AU

T +61 3 9225 5042

BR

T +55 (11) 2246 2700


F +55 (11) 2246 2799

CN:

T +86 10 6310 2386


F +86 10 6310 7786

DE:

T +49 351 40429-0


F +49 351 40429-50

HK:

T +852 2295 6677


F +852 2295 6687

JP:

T +81 3 4578 3322


F +81 3 4578 3328

SG:

T +65 6333 7428


F +65 6333 5540

UK:

T +44 (0)20 8735 6300


F +44 (0)20 8735 6301

T +49 351 40429-0


F +49 351 40429-50

Support
+44 (0)20 8735 6303

You might also like