Professional Documents
Culture Documents
SP A, SP
Submersible pumps, motors and accessories
50 Hz
SP A, SP
Table of contents
1.
2.
3.
4.
5.
General description
Performance range
Applications
Type key
Pumped liquids
Operating conditions
Curve conditions
Pump range
Motor range
Motor protection and controllers
3
4
4
4
4
4
5
5
5
Submersible pumps
6
8
Submersible motors
9
11
12
13
14
SP 1A
SP 2A
SP 3A
SP 5A
SP 8A
SP 14A
SP 17
SP 30
SP 46
SP 60
SP 77
SP 95
SP 125
SP 160
SP 215
14
16
18
20
22
24
26
31
36
41
46
51
56
61
66
Electrical data
71
71
71
72
72
73
74
75
75
76
6.
7.
8.
9.
Accessories
77
77
79
82
83
84
84
85
85
86
86
87
87
88
88
89
91
Energy consumption
93
93
Cable sizing
94
Cables
Sizing of cable
Calculation of the power loss
94
96
96
97
97
98
99
99
100
SP A, SP
General description
1. General description
Performance range
200
20
100
10
1
10
20
40
60
80 100
200
40
SP 215
400
SP160
60
SP 125
600
SP 95
80
SP 77
800
SP 60
100
SP 46
1000
SP 30
200
SP 17
2000
SP 14A
400
50 Hz
SP 8A
4000
SP
SP 5A
600
SP 3A
6000
SP 2A
H
[m]
SP 1A
p
[kPa]
400
Q [m/h]
0.4
0.6 0.8 1
10
20
40
60
Q [l/s]
EuP ready
Pump type
MEI index
Minimum Efficiency Index (MEI) is the dimensionless
scale unit for hydraulic pump efficiency at best
efficiency point, part load and overload.
EU regulations set efficiency requirements to MEI 0.1
as from 1 January 2013 and MEI 0.4 as from 1
January 2015. An indicative benchmark for the
best-performing water pumps available on the market
in 2012 is MEI 0.70.
SP 1A-9
Pump size
Efficiency [%]
MEI
4"
39
0.80
SP 2A-9
4"
50
0.80
SP 3A-9
4"
58
0.80
SP 5A-12
4"
60
0.56
SP 8A-10
4"
61
0.14
SP 11A-9
4"
60
0.10
SP 14A-10
4"
61
0.10
SP 17-9
6"
74
0.76
SP 30-9
6"
75
0.50
SP 46-9
6"
76
0.50
SP 60-9
6"
77
0.60
SP 77-9
8"
78
0.44
SP 95-9
8"
79
0.50
SP 125-9
10"
79
0.37
SP 160-9
10"
80
0.39
SP 215-9
10"
83
0.46
For more information about the new energy directive and MEI index
please visit:
energy.grundfos.com
europump.eu/efficiencycharts
SP A, SP
General description
Applications
Operating pressure
Grundfos motor
Type key
Example
SP
95
Operating conditions
Maximum liquid temperature
Flow velocity
past motor
[m/s]
Max. liquid
temperature
[C]
MS 4"
0.15
40
MS 6000
0.15
30
0.15
60
0.15
60
0.15
25
0.50
30
0.15
45
0.50
50
0.15
25
0.50
30
0.15
40
0.50
45
Note: For MMS 6", 37 kW, MMS 8", 110 kW, and MMS 10", 170 kW,
the maximum liquid temperature is 5 C lower than the values stated in
the table above. For MMS 10", 190 kW, the temperature is 10 C lower.
Curve conditions
The conditions below apply to the curves on pages 14
to 70.
General conditions
Curve tolerances according to ISO 9906, 2012
Grade 3B.
The performance curves show pump performance
at actual speed, cf. standard motor range.
Approximate motor speeds:
4" motors: n = 2870 min-1
6" motors: n = 2870 min-1
8" to 12" motors: n = 2900 min-1.
The measurements were made with airless water at
a temperature of 20 C. The curves apply to a
kinematic viscosity of 1 mm2/s (1 cSt). When
pumping liquids with a density higher than that of
water, use motors with correspondingly higher
outputs.
The bold curves indicate the recommended
performance range.
The performance curves are inclusive of possible
losses such as non-return valve loss.
SP A, SP curves
Pumped liquids
Grundfos motor
MS 402
SP A, SP
Type
SP 1A
SP 2A
SP 3A
SP 5A
Rp 3
Rp 4
(R 4)
Rp 3
Rp 4
Rp 5
Rp 5
Rp 6
Rp 6
Rp 6
5"
5"
6"
6"
6"
Steel:
EN 1.4301
AISI 304
Steel: (N)
EN 1.4401
AISI 316
Steel: (R)
EN 1.4539
AISI 904L
Connection*
Rp 1 1/4
SP 8A SP 14A
Rp 1 1/2 Rp 2
Rp 1 1/4
Rp 1 1/4
(R 1 1/2) (R 2)
(R 1 1/4)
SP 17
Rp 2 1/2 Rp 3
(R 3)
(R 3)
Rp 2
Flange connection:
Grundfos flange
*
General description
Pump range
Motor range
Motor output
[kW]
MS 402
0.37 0.55 0.75 1.1 1.5 2.2 3.0 3.7 4.0 5.5 7.5 9.2 11 13 15 18.5 22 26 30 37 45 55 63 75 92 110 132 147 170 190 220 250
MS 4000 (R)
MS 4000l (R)
MS 6000 (R)
MS 6000l (R)
MMS 6 (N, R)
0.37 0.55 0.75 1.1 1.5 2.2 3.0 3.7 4.0 5.5 7.5 9.2 11 13 15 18.5 22 26 30 37 45 55 63 75 92 110 132 147 170 190 220 250
CUE
MP 204
IO 112
PR 5714
CU 220
Pt100
Pt1000
Zinc anode
Flow sleeve
SA-SPM
R100
CIU
Motor protection of single-phase motors, see section 5. Electrical data, page 71.
SP A, SP
Eta
[%]
100
90
80
70
60
5A
50
8A 14A 17
3A
2A
40
30
60 95 160
46 77 125 215
1A
30
20
10
0
0,1
0
Example
When pumping 200 m3/h at a head of 100 m for a
period of 10 years, EUR 60,000 will be saved if a
pump/motor having a 10 % higher efficiency is chosen
and the price is EUR 0.10 per kWh.
50 Hz
10
50
100
500
Q [m/h]
Fig. 1
Fig. 2
Various SP pumps
Submersible pumps
2. Submersible pumps
Gr6389 2806
2
Submersible pumps
SP A, SP
Fig. 3
Bearing
Fig. 4
Inlet strainer
Inlet strainer
TM00 7302 1096
Valve flap
Fig. 5
Non-return valve
Fig. 6
Priming screw
Non-return valve
Priming screw
Fig. 7
SP A, SP
Pos. Component
1
Valve casing
Stainless steel
1d
O-ring
NBR
Valve cup
Stainless steel
Valve seat
Standard/
N-version:
NBR
R-version:
FKM
Standard
N-version R-version
EN/AISI
1.4301/
304
1.4401/
316
1.4539/
904L
1.4301/
304
1.4401/
316
1.4539/
904L
1
70
39
2
3b
3
1.4408/
316
1.4517
1.4301/
304
1.4401/
316
1.4539/
904L
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
8a
Upper bearing
Stainless steel/
NBR
1.4401/
304
1.4401/
316
1.4539/
904L
11c
Neck ring
NBR/PPS
Bearing
NBR
8a
Washer for
stop ring
Carbon/graphite
HY22 in PTFE
mass
8b
Stop ring
Stainless steel
1.4401/
316
1.4401/
316
1.4539/
904L
Chamber
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
11
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
11c
Stainless steel
1.4401/
316
1.4401/
316
1.4539/
904L
12
Split cone
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
13
Impeller
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
14
Suction
interconnector
Cast stainless
steel
1.4308
1.4408/
316
1.4517
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
17
16
1.4057/
431
1.4460/
329
1.4462/
904L
71
17
Strap
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
18
Cable guard
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
19
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
39
Spring for
valve cup
Stainless steel
1.4301/
304
1.4401/
316
1.4462/
SAF 2205
70
Valve guide
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
71
Washer
Stainless steel
1.4401/
316
1.4401/
316
1.4539/
904L
72
Wear ring
Stainless steel
1.4301/
304
1.4401/
316
1.4539/
904L
3a
3b
4
6
15
Material
Lower valve
seat retainer
Stainless steel
Upper valve
seat retainer
Stainless steel
Top chamber
Strainer
1.4308
1d
3a
6
8b
7
8
13
72
7
8
11
16
7
12
18
15
14
19
Fig. 8
SP 77
Submersible pumps
Material specification
SP A, SP
Submersible motors
3. Submersible motors
Features and benefits
A complete motor range
Grundfos offers a complete range of submersible
motors in different voltages:
Submersible motors, MS
4" motors, single-phase up to 2.2 kW:
2-wire
3-wire
PSC (permanent split capacitor)
4" motors, three-phase up to 7.5 kW
4" industrial motors, three-phase up to 5.5 kW
6" motors, three-phase from 5.5 to 30 kW
6" industrial motors, three-phase up to 22 kW.
Submersible, rewindable motors, MMS
6" motors, three-phase from 3.7 to 37 kW
8" motors, three-phase from 22 to 110 kW
10" motors, three-phase from 75 to 190 kW
12" motors, three-phase from 147 to 250 kW.
Fig. 9
MS motors
SP A, SP
Submersible motors
Overtemperature protection
Protecting the motor against too high motor
temperature is the simplest and cheapest way of
avoiding that the motor life is reduced.
Accessories for protection against overtemperature
are available for both Grundfos MS and MMS
submersible motors. When the temperature becomes
too high, the protection device will cut out, and
damage to the pump and motor will be avoided.
MS
The Grundfos MS submersible motors, except MS 402,
are available with built-in Tempcon temperature sensor
for protection against overtemperature. By means of
this sensor it is possible to read out and/or monitor the
motor temperature via an MP 204 motor protector.
MMS
The Grundfos MMS submersible motors are not
available with built-in Tempcon temperature sensor.
For these motors, we offer Pt100 and Pt1000 sensors
for temperature monitoring. Together with either an
MP 204 motor protector, a PR 5714 relay or a CU 220
control unit, the sensor ensures that the operating
conditions are not exceeded.
Protection against upthrust
In case of a very low counter pressure in connection
with start-up, there is a risk that the entire chamber
stack may rise. This is called upthrust. Upthrust may
damage both pump and motor. Therefore, both
Grundfos pumps and motors are protected against
upthrust as standard, preventing upthrust from
occurring in the critical start-up phase. The protection
consists of either a built-in stop ring or hydraulic
balancing.
Built-in cooling chambers
Fig. 11 MS 4000
10
SP A, SP
Submersible motors
Lightning protection
The smallest Grundfos submersible motors, i.e.
MS 402, are all insulated in order to minimise the risk
of motor burnout caused by stroke of lightning.
Reduced risk of short-circuit
The embedded stator winding in the Grundfos MS
submersible motor is hermetically enclosed in
stainless steel. The result is high mechanical stability
and optimum cooling. Also, this eliminates the risk of
short-circuit of the windings caused by condensed
water.
Shaft seal
MS 402
The shaft seal is of the lip seal type characterised by
low friction against the rotor shaft.
The choice of rubber offers good wear resistance,
good elasticity and resistance to particles. The rubber
material is approved for use in drinking water.
The material is ceramic/tungsten carbide providing
optimum sealing, optimum wear resistance and long
life.
The spring-loaded shaft seal is designed with a large
surface and a sand shield. The result is a minimum
exchange of pumped liquid and motor liquid and no
penetration of particles. Motors, version R, have a
SiC/SiC shaft seal according to DIN 24960. Other
combinations are available on request.
MS 4000, MS 6000
11
SP A, SP
Submersible motors
Shaft
Shaft seal
Motor sleeve
MS 402
MS 4000
MS 6000
EN 1.4057
EN 1.4057
NBR
Ceramic/tungsten
carbide
EN 1.4301
EN 1.4301
Ceramic
Ceramic/tungsten
carbide
EN 1.4301
Radial bearing
Axial bearing
Ceramic/carbon
Ceramic/carbon
Rubber parts
NBR
NBR
R-version motor
Pos. Component
MS 4000
MS 6000
Shaft
Shaft seal
Motor sleeve
EN 1.4539
EN 1.4539
Radial bearing
Ceramic/tungsten
carbide
Thrust bearing
Ceramic/carbon
Rubber parts
EN 1.4462
NBR/ceramic
NBR
Fig. 13 MS 4000
12
SP A, SP
Submersible motors
Material
Shaft
220
EN
Steel
1.0533
Stainless steel
1.4460
6"
3.7 to 15 kW
226
Hardened
steel/EPDM
Thrust bearing 12"
203/
Stationary/
206
6"
rotating part
18.5 to 37 kW Ceramic/
carbon
8" to 10"
6" to 10"
Carbon
12"
Stainless
steel/NBR
204
Bearing bush
205
Cast iron
212
Diaphragm
CR
213
Cast iron
202a
204
EN-JL1040
205
EN-JL1040
218
Motor sleeve
Stainless steel
220
Motor cable
EPDM
235
Shaft seal
Ceramic/
carbon
202
226
1.4301
235
Intermediate housing
Cast iron
EN-JL1040
236
Cast iron
EN-JL1040
218
Material
202
Steel
EN
EN
1.0533
1.0533
1.4462
202a
Hardened
steel/EPDM
Ceramic/
carbon
206
Bearing bush
6" to 10"
Carbon
Bearing bush
12"
Stainless
steel/NBR
205
212
Diaphragm
CR
213
1.4539
218
Motor sleeve
1.4539
220
Motor cable
EPDM
226
Shaft seal
Ceramic/
carbon
235
Intermediate housing
1.4539
236
1.4539
204
236
203
1.4539
213
212
Shaft
13
SP A, SP
SP 1A
H
[m]
SP 1A
320
50 Hz
-57
-50
260
2400
240
-42
220
2000
-36
200
180
1600
-28
160
140
1200
-21
120
-18
100
800
-14
80
60
400
-9
40
20
0
0.0
0.2
0.0
P2
[hp]
0.4
0.6
0.1
0.8
0.2
1.2
0.3
P2
[kW]
1.4
Q [m/h]
0.4
Q [l/s]
Eta
0.04
0.04
1.0
Eta
[%]
40
0.03
30
P2
0.02
20
0.02
0.01
0.00
10
0.00
0
0.0
0.2
0.4
0.6
0.8
1.0
14
1.2
1.4
Q [m/h]
SP 1A
SP A, SP
101
Pump type
Rp 1 1/4
95
1A-9
1A-14
1A-18
1A-21
1A-28
1A-36
1A-42
1A-50
1A-57
MS
MS
MS
MS
MS
MS
MS
MS
MS
402
402
402
402
402
402
402
402
402
Power
[kW]
0.37
0.37
0.55
0.55
0.75
1.1
1.1
1.5
1.5
344
449
533
596
743
956
1082
1250
1397
Net weight
[kg]
1x230V
3x230V
3x400V
1x230V
3x230V
3x400V
1x230V
3x230V
3x400V
256
256
291
291
306
346
346
346
346
226
226
241
241
276
306
306
346
346
600
705
824
887
1049
1302
1428
1596
1743
570
675
774
837
1019
1262
1388
1596
1743
11
12
14
14
16
25
27
30
32
9
10
12
12
15
23
25
29
32
SP
SP
SP
SP
SP
SP
SP
SP
SP
Type
Dimensions [mm]
15
SP A, SP
SP 2A
SP 2A
Performance curves
p
[kPa]
H
[m]
SP 2A
5600
560
50 Hz
-90
480
-75
440
4000
400
-65
360
-55
3200
320
-48
280
2400
-40
240
-33
200
-28
1600
160
-23
120
800
-18
-13
80
-9
-6
40
0
0.0
P2
[hp]
0.4
0.0
0.8
1.2
0.2
P2
[kW]
1.6
0.4
0.04
0.02
0.00
2.8
Q [m/h]
0.8
Q [l/s]
Eta
0.04
Eta
[%]
50
40
P2
0.03
30
0.02
20
0.01
10
0.00
0
0.0
0.4
0.8
1.2
1.6
2.0
16
2.4
0.6
0.05
0.06
2.0
2.4
2.8
Q [m/h]
SP 2A
SP A, SP
101
Rp 1 1/4
95
Pump type
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
2A-6
2A-9
2A-13
2A-18
2A-23
2A-28
2A-33
2A-40
2A-40
2A-48
2A-48
2A-55
2A-65
2A-75
2A-90
Type
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
402
402
402
402
402
402
402
4000
402
4000
402
4000
4000
4000
4000
Dimensions [mm]
B
Power
[kW]
0.37
0.37
0.55
0.75
1.1
1.5
1.5
2.2
2.2
2.2
2.2
3.0
3.0
4.0
4.0
281
344
428
533
638
743
844
1040
1040
1208
1208
1355
1565
1954
2269
1x230V
256
256
291
306
346
346
346
573
Net weight
[kg]
A
3x230V
3x400V
226
226
241
276
306
346
346
1x230V
537
600
719
839
984
1089
1190
1613
346
573
3x230V
3x400V
507
570
669
809
944
1089
1190
10
11
13
15
17
19
20
37
1386
1781
346
493
493
573
573
1x230V
3x230V
3x400V
9
9
11
13
16
18
19
27
39
1554
1848
2058
2527
2842
30
38
41
57
64
17
SP A, SP
SP 3A
SP 3A
Performance curves
p
[kPa]
H
[m]
SP 3A
-60
50 Hz
3600
360
3200
2800
2400
-52
320
-45
280
-39
240
-33
2000
200
-29
1600
-25
160
-22
1200
120
-18
-15
800
-12
80
-9
40
-6
0.0
0.4
0.0
P2
[hp]
P2
[kW]
0.16
0.12
0.12
0.09
0.08
0.06
0.04
0.03
0.00
0.00
0.8
1.2
0.2
1.6
2.0
0.4
2.4
2.8
0.6
0.8
3.6
4.0
1.0
Q [m/h]
1.2
Q [l/s]
Eta
Eta
[%]
60
45
30
P2
15
0
0.0
0.4
0.8
1.2
1.6
2.0
2.4
2.8
18
3.2
3.2
3.6
4.0
Q [m/h]
400
SP 3A
SP A, SP
101
Rp 1 1/4
95
Pump type
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
3A-6*
3A-6N
3A-6N
3A-9*
3A-9N
3A-9N
3A-12*
3A-12N
3A-12N
3A-15*
3A-15N
3A-15N
3A-18*
3A-18N
3A-18N
3A-22*
3A-22N
3A-22N
3A-25*
3A-25N
3A-25N
3A-29*
3A-29*
3A-29N
3A-33*
3A-33*
3A-33N
3A-39
3A-45
3A-52
3A-60
Type
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
402
4000R
4000R
402
4000R
4000R
402
4000R
4000R
402
4000R
4000R
402
4000R
4000R
402
4000R
4000R
402
4000R
4000R
4000
402
4000R
4000
402
4000R
4000
4000
4000
4000
Dimensions [mm]
B
Power
[kW]
0.37
2.2
0.75
0.55
2.2
0.75
0.75
2.2
0.75
1.1
2.2
1.1
1.1
2.2
1.1
1.5
2.2
1.5
1.5
2.2
1.5
2.2
2.2
2.2
2.2
2.2
2.2
3.0
3.0
4.0
4.0
281
326
326
344
389
389
407
452
452
470
515
515
533
578
578
617
662
662
680
725
725
764
764
809
848
848
893
1019
1145
1292
1460
1x230V
256
573
291
573
306
573
346
573
346
573
346
573
346
573
3x230V
3x400V
226
398
241
398
276
398
306
413
306
413
346
413
346
1x230V
537
899
635
962
713
1025
816
1088
879
1151
963
1235
1026
1298
413
573
573
573
573
Net weight
[kg]
A
3x230V
3x400V
507
724
585
787
683
850
776
928
839
991
963
1075
1026
346
453
493
493
573
573
10
26
12
27
13
28
16
29
16
30
18
31
18
32
1138
1337
346
453
1x230V
1382
1421
1466
3x230V
3x400V
9
18
10
19
12
20
14
22
15
23
17
24
18
25
29
1110
1262
1194
1346
1512
1638
1865
2033
33
30
34
20
28
21
29
32
34
41
43
* Pumps with spline shaft are only available in stainless steel EN 1.4301/AISI 304.
Note: All other pumps listed above are also available in N- and R-versions. See page 5.
19
SP A, SP
SP 5A
SP 5A
Performance curves
p
[kPa]
H
[m]
SP 5A
5600
560
50 Hz
-85
520
4800
480
-75
440
4000
400
-60
360
3200
-52
320
-44
280
2400
-38
240
-33
200
1600
-25
160
-21
120
80
-12
40
-8
-6
-4
0
0.0
0.8
0.0
P2
[hp]
P2
[kW]
0.16
0.12
1.6
2.4
0.4
3.2
4.0
0.8
4.8
1.2
5.6
6.4 Q
1.6
[m/h]
Q [l/s]
Eta
0.08
60
40
P2
0.08
0.04
0.00
20
0.00
0
0.0
0.8
1.6
2.4
3.2
4.0
20
Eta
[%]
4.8
5.6
6.4 Q
[m/h]
800
-17
SP 5A
SP A, SP
E
Rp 1 1/2
Pump type
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
5A-4*
5A-4N
5A-4N
5A-6*
5A-6N
5A-6N
5A-8*
5A-8N
5A-8N
5A-12*
5A-12N
5A-12N
5A-17*
5A-17N
5A-17N
5A-21*
5A-21*
5A-21N
5A-25*
5A-25*
5A-25N
5A-33*
5A-33N
5A-38
5A-44
5A-52
5A-60
5A-52
5A-60
5A-75
5A-85
Type
MS 402
MS 4000R
MS 4000R
MS 402
MS 4000R
MS 4000R
MS 402
MS 4000R
MS 4000R
MS 402
MS 4000R
MS 4000R
MS 402
MS 4000R
MS 4000R
MS 4000
MS 402
MS 4000R
MS 4000
MS 402
MS 4000R
MS 4000
MS 4000R
MS 4000
MS 4000
MS 4000
MS 4000
MS 6000
MS 6000
MS 6000
MS 6000
Dimensions [mm]
B
Power
[kW]
0.37
2.2
0.75
0.55
2.2
0.75
0.75
2.2
0.75
1.1
2.2
1.1
1.5
2.2
1.5
2.2
2.2
2.2
2.2
2.2
2.2
3.0
3.0
4.0
4.0
5.5
5.5
5.5
5.5
7.5
7.5
240
284
284
282
326
326
324
368
368
408
452
452
513
557
557
597
597
641
681
681
725
849
893
998
1124
1292
1460
1354
1522
2146
2356
1x230V
256
573
291
573
306
573
346
573
346
573
3x230V
3x230V
1x230V
3x400V
3x400V
226
398
241
398
276
398
306
413
346
496
857
573
899
630
941
754
1025
859
1130
413
573
573
573
573
Net weight
[kg]
466
682
523
724
600
766
714
865
859
970
1170
346
453
346
453
493
493
573
573
673
673
541
541
571
571
1214
1254
1298
943
1094
1027
1178
1342
1386
1571
1697
1965
2133
1895
2063
2717
2927
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
138
138
138
138
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
138
138
140
140
1x230V
10
25
11
26
13
27
15
28
17
29
3x230V
3x400V
8
17
10
18
11
19
13
21
16
22
27
30
28
32
18
25
19
27
26
30
36
38
46
48
60
63
86
92
21
SP A, SP
SP 8A
SP 8A
Performance curves
p
[kPa]
H
[m]
SP 8A
700
50 Hz
ISO 9906:2012 Grade 3B
6400
-110
650
600
-100
550
-91
5600
4800
500
-82
450
4000
-73
400
-66
350
-58
300
-50
3200
-44
2400
250
-37
200
-30
1600
-25
150
-21
-18
-15
-12
100
800
-10
-7
-5
50
0
0
0.0
0.5
1.0
1.5
2.0
10
2.5
Q [m/h]
3.0
Q [l/s]
P2
P2
[hp] [kW]
0.24
Eta
60
0.2
0.16
P2
40
0.1
0.08
0.0
0.00
0.3
20
0
0
22
Eta
[%]
10
Q [m/h]
SP 8A
SP A, SP
Dimensions [mm]
E
Pump type
Rp 2
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
8A-5
8A-5
8A-5
8A-7
8A-7
8A-7
8A-10
8A-10
8A-10
8A-12
8A-12
8A-12
8A-15
8A-15
8A-15
8A-18
8A-21
8A-25
8A-30
8A-37
8A-30
8A-37
8A-44
8A-44
8A-50
8A-50
8A-58
8A-66
8A-73
8A-82
8A-91
8A-100
8A-110
Type
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
402
4000
4000R
402
4000
4000R
402
4000
4000R
4000
402
4000
4000
402
4000
4000
4000
4000
4000
4000
6000
6000
4000
6000
4000
6000
6000
6000
6000
6000
6000
6000
6000
Power
[kW]
0.75
2.2
0.75
1.1
2.2
1.1
1.5
2.2
1.5
2.2
2.2
2.2
2.2
2.2
2.2
3.0
4.0
4.0
5.5
5.5
5.5
5.5
7.5
7.5
7.5
7.5
9.2
11.0
11.0
13.0
15.0
15.0
18.5
409
409
409
493
493
493
619
619
619
703
703
703
829
829
829
955
1081
1249
1459
1753
1521
1521
1815
2109
2303
2361
3013
3349
3643
4021
4399
4777
5197
1x230V
306
573
346
573
346
573
3x230V
3x230V
1x230V
3x400V
3x400V
276
398
306
413
346
715
982
839
1066
965
1192
413
573
573
573
573
Net weight
[kg]
685
807
799
906
965
1032
1276
346
453
346
453
493
573
573
673
673
541
541
773
571
773
571
601
631
631
661
696
696
751
1276
1402
1402
1049
1156
1175
1282
1448
1654
1822
2132
2426
2062
2356
2824
2680
3076
2932
3614
3980
4274
4682
5095
5473
5948
E
1x230V
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
138
138
95
138
95
138
138
138
138
138
138
138
138
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
138
138
101
138
101
138
140
140
140
140
140
140
140
15
27
17
28
19
30
3x230V
3x400V
13
19
16
21
19
23
30
30
32
32
21
25
23
27
29
35
37
45
49
56
60
60
66
64
70
104
114
120
131
143
150
164
23
SP 14A
SP 14A
SP A, SP
Performance curves
p
[kPa]
H
[m]
SP 14A
-25
170
50 Hz
1600
160
150
1400
140
130
1200
-18
120
110
1000
100
-13
90
800
80
70
600
-10
60
50
400
-7
40
-5
30
200
20
10
0
0
10
12
14
16
18
Q [m/h]
Q [l/s]
P2
P2
[hp] [kW]
0.4
Eta
0.3
Eta
[%]
60
0.2
40
0.1
20
0.2
0.0
0.0
0
0
10
12
24
14
16
18
Q [m/h]
P2
SP 14A
SP A, SP
E
Pump type
Rp 2
SP
SP
SP
SP
SP
SP
SP
SP
SP
14A-5
14A-7
14A-7
14A-10
14A-13
14A-18
14A-25
14A-18
14A-25
Type
MS
MS
MS
MS
MS
MS
MS
MS
MS
402
4000
402
4000
4000
4000
4000
6000
6000
Dimensions [mm]
B
Power
[kW]
1.5
2.2
2.2
3.0
4.0
5.5
7.5
5.5
7.5
510
640
640
835
1030
1355
1810
1417
1872
1x230V
346
573
Net weight
[kg]
A
3x230V
3x400V
346
346
493
573
673
773
541
571
1x230V
856
1213
3x230V
3x400V
856
95
95
95
95
95
95
95
138
138
101
101
101
101
101
101
101
138
138
986
1328
1603
2028
2584
1958
2443
1x230V
18
29
3x230V
3x400V
17
19
27
33
41
67
52
60
25
SP A, SP
SP 17
SP 17
Performance curves
p
[kPa]
H
[m]
50 Hz
1800
1600
180
-16
170
-15
160
-14
150
1400
-13
140
-12
130
1200
SP 17
-17
190
-11
120
-10
110
1000
-9
100
-8
90
800
600
80
-7
70
-6
60
-5
50
400
-4
40
-3
30
-2
200
20
-1
10
0
0
p
[kPa]
10
12
14
18
20
80
60
40
20
Q [m/h]
6
H
[m]
Q [l/s]
Eta
[%]
80
Eta
60
40
NPSH
20
0
10
12
14
26
16
16
18
20
Q [m/h]
6400
SP 17
p
[kPa]
H
[m]
SP 17
-60
-58
650
50 Hz
ISO 9906:2012 Grade 3B
-55
600
-53
-51
5600
550
-48
-45
500
4800
-43
450
4000
-40
-39
-38
-37
-36
-35
-34
-33
-32
-31
-30
-29
-28
-27
-26
-25
-24
-23
-22
-21
-20
-19
-18
400
350
3200
300
2400
SP A, SP
250
200
1600
150
100
800
50
0
10
12
14
16
18
20
H
[m]
80
60
40
20
Q [m/h]
Q [l/s]
Eta
Eta
[%]
80
60
40
NPSH
20
0
10
12
14
16
18
20
Q [m/h]
p
[kPa]
27
SP 17
Motor
Rp 2 1/2
Pump type
C
B
28
SP A, SP
Type
SP
SP
SP
SP
SP
SP
17-1
17-1
17-2
17-2
17-3
17-4
MS
MS
MS
MS
MS
MS
402
4000
402
4000
4000
4000
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
17-1
17-1
17-2
17-2
17-3
17-3
17-4
17-4
17-5
17-6
17-7
17-8
17-9
17-10
17-11
17-12
17-13
17-8
17-9
17-10
17-11
17-12
17-13
17-14
17-15
17-16
17-17
17-18
17-19
17-20
17-21
17-22
17-23
17-24
17-25
17-26
17-27
17-28
17-29
17-30
17-31
17-32
17-33
17-34
17-35
17-36
17-37
17-38
17-39
17-40
17-43
17-45
17-48
17-51
17-53
17-55
17-58
17-60
MS 402
MS 4000
MS 402
MS 4000
MS 402
MS 4000
MS 402
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MMS6
MMS6
MMS6
Dimensions [mm]
Power
[kW]
Single-phase, 1 x 230 V
0.55
324
317
641
95
2.2
324
577
901
95
1.1
384
387
771
95
2.2
384
577
961
95
2.2
444
577
1021
95
2.2
504
577
1081
95
Three-phase, 3 x 230 V / 3 x 400 V
0.55
324
282
606
95
0.75
324
402
726
95
1.1
384
347
731
95
1.1
384
417
801
95
2.2
444
387
831
95
2.2
444
457
901
95
2.2
504
387
891
95
2.2
504
457
961
95
3.0
564
497
1061
95
4.0
624
577
1201
95
4.0
684
577
1261
95
5.5
744
677
1421
95
5.5
804
677
1481
95
5.5
864
677
1541
95
7.5
924
777
1701
95
7.5
984
777
1761
95
7.5
1044
777
1821
95
5.5
763
544
1307
143
5.5
823
544
1367
143
5.5
883
544
1427
143
7.5
943
574
1517
143
7.5
1003
574
1577
143
7.5
1063
574
1637
143
9.2
1123
604
1727
143
9.2
1183
604
1787
143
9.2
1243
604
1847
143
9.2
1303
604
1907
143
11
1363
634
1997
143
11
1423
634
2057
143
11
1483
634
2117
143
13
1543
664
2207
143
13
1603
664
2267
143
13
1663
664
2327
143
13
1723
664
2387
143
15
1783
699
2482
143
15
1843
699
2542
143
15
1903
699
2602
143
18.5
1963
754
2717
143
18.5
2023
754
2777
143
18.5
2083
754
2837
143
18.5
2143
754
2897
143
18.5
2203
754
2957
143
18.5
2263
754
3017
143
22
2323
814
3137
143
22
2383
814
3197
143
22
2443
814
3257
143
22
2503
814
3317
143
22
2563
814
3377
143
22
2623
814
3437
143
22
2683
814
3497
143
26
3215
874
4089
143
26
3335
874
4209
143
26
3515
874
4389
143
30
3695
944
4639
143
30
3815
944
4759
143
37
3935
1312
5247
144
37
4115
1312
5427
144
37
4235
1312
5547
144
E*
E**
Net weight
[kg]
134
134
134
134
134
134
12
26
17
27
28
30
134
134
134
134
134
134
134
134
134
134
134
134
134
134
134
134
134
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
175
175
175
175
175
175
175
175
11
18
15
20
19
23
21
25
27
32
34
40
42
43
50
51
53
49
50
52
56
58
59
66
67
69
70
75
76
77
82
83
84
86
91
92
94
101
102
103
105
106
108
115
116
118
119
120
122
123
164
167
173
186
189
234
240
243
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
181
181
181
181
181
181
181
181
SP 17
SP A, SP
Power curves
P2
P2
[hp] [kW]
10.0
SP 17
9.6
50 Hz
13
9.2
-17
12
8.8
-16
8.4
11
-15
8.0
-14
7.6
10
7.2
-13
6.8
9
-12
6.4
6.0
-11
5.6
7
-10
5.2
4.8
-9
4.4
-8
4.0
5
-7
3.6
-6
3.2
4
2.8
-5
2.4
3
-4
2.0
-3
1.6
1.2
-2
-1
0.4
0
0.0
0
10
12
14
16
18
20
Q [m/h]
6
Q [l/s]
0.8
29
SP A, SP
SP 17
P2
P2
[hp] [kW]
SP 17
50
50 Hz
36
48
46
44
42
35
34
33
-60
32
-58
31
-55
30
40
38
29
-53
28
-51
27
36
26
34
-48
25
-45
24
32
-43
23
30
28
22
-40
-39
-38
-37
-36
-35
-34
21
20
26
24
19
18
-33
-32
-31
-30
-29
-28
17
22
20
16
15
-27
-26
-25
14
18
16
13
-24
-23
-22
-21
12
11
14
12
-20
-19
-18
10
9
8
7
6
5
0
30
10
12
14
16
18
20
Q [m/h]
6
Q [l/s]
10
SP 30
SP A, SP
SP 30
Performance curves
p
[kPa]
H
[m]
SP 30
-15
170
50 Hz
-14
1600
160
1400
150
-13
140
-12
130
1200
-11
120
-10
110
-9
1000
100
-8
90
800
600
400
-7
80
70
-6
60
-5
50
-4
40
-3
30
-2
200
20
-1
10
0
0
p
[kPa]
12
16
20
24
28
32
36
Q [m/h]
10
Q [l/s]
H
[m]
Eta
[%]
80
60
60
40
40
20
Eta
80
NPSH
20
0
12
16
20
24
28
32
36
Q [m/h]
31
SP 30
p
[kPa]
H
[m]
6400
650
SP A, SP
SP 30
50 Hz
ISO 9906:2012 Grade 3B
-54
6000
-52
600
5600
-49
550
-46
5200
500
-43
4800
4400
4000
450
-39
-35
400
-34
-31
350
-30
3200
-28
300
-26
2800
2400
-24
-29
-27
-25
-23
-22
250
-21
-20
2000
-33
-32
3600
-19
-18
200
-17
-16
1600
150
1200
100
800
50
0
12
16
20
24
32
36
Q [m/h]
10
Q [l/s]
H
[m]
80
60
40
20
Eta
Eta
[%]
80
60
40
NPSH
20
0
12
16
20
24
32
28
28
32
36
Q [m/h]
p
[kPa]
SP 30
SP A, SP
Motor
Rp 3
Type
Dimensions [mm]
Net weight
[kg]
Pump type
SP 30-1
SP 30-1
SP 30-2
MS 402
MS 4000
MS 4000
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
MS 402
MS 4000
MS 402
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MMS6
MMS6
MMS 8000
MMS 8000
MMS 8000
MMS 8000
30-1
30-1
30-2
30-2
30-3
30-4
30-5
30-6
30-7
30-8
30-5
30-6
30-7
30-8
30-9
30-10
30-11
30-12
30-13
30-14
30-15
30-16
30-17
30-18
30-19
30-20
30-21
30-22
30-23
30-24
30-25
30-26
30-27
30-28
30-29
30-30
30-31
30-32
30-33
30-34
30-35
30-39
30-43
30-46
30-49
30-52
30-54
Power
[kW]
Single-phase, 1 x 230 V
1.1
358
387
745
2.2
358
577
935
2.2
454
577
1031
Three-phase, 3 x 230 V / 3 x 400 V
1.1
358
347
705
1.1
358
417
775
2.2
387
457
844
2.2
454
457
911
3.0
550
497
1047
4.0
646
577
1223
5.5
742
677
1419
5.5
838
677
1515
7.5
934
777
1711
7.5
1030
777
1807
5.5
761
544
1305
5.5
857
544
1401
7.5
953
574
1527
7.5
1049
574
1623
9.2
1145
604
1749
9.2
1241
604
1845
9.2
1337
604
1941
11
1433
634
2067
11
1529
634
2163
13
1625
664
2289
13
1721
664
2385
15
1817
699
2516
15
1913
699
2612
18.5
2009
754
2763
18.5
2105
754
2859
18.5
2201
754
2955
18.5
2297
754
3051
22
2393
814
3207
22
2489
814
3303
22
2585
814
3399
22
2681
814
3495
22
2777
814
3591
26
2873
874
3747
26
2969
874
3843
26
3065
874
3939
26
3161
874
4035
26
3257
874
4131
30
3353
944
4297
30
3449
944
4393
30
3545
944
4489
30
3641
944
4585
37
4377
1312
3982
37
4761
1312
4095
45
4993
1270
4781
45
5281
1270
5007
55
5569
1350
5652
55
5761
1350
5878
E*
E**
95
95
95
134
134
134
16
27
29
95
95
95
95
95
95
95
95
95
95
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
144
144
192
192
192
192
134
134
134
134
134
134
134
134
134
134
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
142
175
175
192
192
192
192
15
20
19
24
26
32
39
41
48
50
47
49
55
57
64
66
68
73
75
80
82
88
90
97
99
101
103
111
113
115
117
119
126
128
130
132
134
144
146
148
150
248
259
326
334
357
362
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
181
181
192
192
192
192
The pump types above are also available in N- and R-versions. See page 5.
Pumps mounted in sleeve are only available in standard and N-versions.
Other types of connection are possible by means of connecting pieces. See page 83.
33
SP A, SP
SP 30
Power curves
P2
P2
[hp] [kW]
SP 30
13.6
50 Hz
18
16
-14
11.2
-13
14
10.4
-12
9.6
-11
12
8.8
-10
8.0
-9
10
7.2
-8
6.4
-7
8
5.6
-6
4.8
6
-5
4.0
-4
3.2
4
-3
2.4
-2
1.6
-1
0.8
0.0
0
34
12
16
20
24
28
32
36
Q [m/h]
10
Q [l/s]
SP 30
SP A, SP
P2
P2
[hp] [kW]
SP 30
52
50 Hz
68
50
48
-54
64
46
60
-52
44
-49
42
56
-46
40
52
38
36
-43
48
34
44
40
-39
32
30
-35
-34
-33
-32
28
36
32
26
-31
-30
-29
-28
-27
24
22
28
24
-26
-25
-24
-23
-22
20
18
-21
-20
-19
-18
16
20
-17
-16
14
16
12
10
12
6
0
12
16
20
24
28
32
36
Q [m/h]
10
Q [l/s]
35
SP A, SP
SP 46
SP 46
Performance curves
p
[kPa]
H
[m]
SP 46
2000
50 Hz
-15
200
180
1600
-13
-12
160
-11
140
-10
1200
-9
120
-9-C
-8
-8-C
-7
100
800
-6
80
-5
60
-4
400
-4-C
-3
40
-3-C
-2
-2-BB
-1
20
-1-B
0
0
10
p
[kPa]
20
30
40
10
60
15
80
60
40
20
Q [m/h]
Q [l/s]
H
[m]
Eta
Eta
[%]
80
60
40
NPSH
20
0
10
20
30
40
36
50
50
60
Q [m/h]
SP 46
p
[kPa]
SP A, SP
H
[m]
SP 46
50 Hz
520
-37
4800
480
-35
-33
440
4000
-30
400
-28
360
3200
2400
-26
280
-24
-23
-22
-21
240
-20
-19
-18
320
-17
-16
200
1600
160
120
800
80
40
0
10
30
40
50
10
60
15
Q [l/s]
H
[m]
80
60
40
20
Q [m/h]
Eta
Eta
[%]
80
60
40
NPSH
20
0
10
20
30
40
50
60
Q [m/h]
p
[kPa]
20
37
SP A, SP
SP 46
Rp 3
Rp 4
Pump type
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
46-1-B
46-1
46-2-BB
46-2
46-3-C
46-3
46-4-C
46-4
46-5
46-3
46-4-C
46-4
46-5
46-6
46-7
46-8-C
46-8
46-9-C
46-9
46-10
46-11
46-12
46-13
46-14
46-15
46-16
46-17
46-18
46-19
46-20
46-21
46-22
46-23
46-24
46-26
46-28
46-30
46-33
46-35
46-37
Type
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MMS6
MMS6
MMS6
MMS6
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
Dimensions [mm]
Rp 3/Rp 4 connection
Power
[kW]
E*
1.1
2.2
2.2
3.0
4.0
5.5
5.5
7.5
7.5
5.5
5.5
7.5
7.5
9.2
11
11
13
13
15
15
18.5
18.5
22
22
22
26
26
30
30
30
37
37
37
37
45
45
45
55
55
63
795
835
948
988
1181
1281
1394
1494
1607
1164
1277
1307
1420
1563
1706
1819
1849
1962
1997
2110
2278
2391
2580
2693
2806
2979
3092
3275
3388
3501
3982
4095
4208
4321
4781
5007
5233
5652
5878
6244
378
378
491
491
604
604
717
717
830
620
733
733
846
959
1072
1185
1185
1298
1298
1411
1524
1637
1766
1879
1992
2105
2218
2331
2444
2557
2670
2783
2896
3009
3511
3737
3963
4302
4528
4754
146
146
146
146
146
146
146
146
146
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
150
150
150
150
192
192
192
192
192
192
E**
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
153
153
153
153
192
192
192
192
192
192
Net weight
[kg]
417
457
457
497
577
677
677
777
777
544
544
574
574
604
634
634
664
664
699
699
754
754
814
814
814
874
874
944
944
944
1312
1312
1312
1312
1270
1270
1270
1350
1350
1490
95
95
95
95
95
95
95
95
95
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
144
144
144
144
192
192
192
192
192
192
21
23
26
27
33
38
40
45
48
48
51
54
57
64
70
72
75
78
82
84
92
94
103
106
108
116
118
129
131
134
176
179
181
183
278
284
290
314
320
352
38
SP 46
SP A, SP
Power curves
P2
P2
[hp] [kW]
SP 46
50 Hz
ISO 9906:2012 Grade 3B
22
28
-15
20
-14
-13
18
24
-12
16
-11
20
14
-10
-9
16
12
-9-C
-8
-8-C
10
-7
12
-6
8
-5
8
-4
-4-C
-3
-3-C
-2
2
-2-BB
-1
0
0
10
20
30
40
10
50
60
15
Q [m/h]
Q [l/s]
-1-B
39
SP A, SP
SP 46
P2
P2
[hp] [kW]
SP 46
58
50 Hz
ISO 9906:2012 Grade 3B
56
75
54
-37
70
52
-35
50
65
48
-33
46
60
44
-30
42
55
-28
40
38
-26
50
36
34
-24
45
32
-23
-22
40
30
-21
28
35
-20
-19
26
-18
24
-17
30
-16
22
20
25
18
16
14
0
40
10
20
30
40
10
50
60
15
Q [m/h]
Q [l/s]
20
SP 60
SP A, SP
SP 60
Performance curves
p
[kPa]
H
[m]
SP 60
-10
1400
140
50 Hz
ISO 9906:2012 Grade 3B
130
1200
-9
-9-B
120
-8
110
1000
-8-B
-7
100
90
-6
800
80
-5
70
600
60
-4
50
-3
400
40
30
-2
-2-B
200
20
-1
10
0
0
10
p
[kPa]
20
30
40
50
10
60
15
70
80 Q
20
Q [l/s]
H
[m]
80
60
40
20
[m/h]
Eta
Eta
[%]
80
60
40
NPSH
20
0
0
10
20
30
40
50
60
70
80 Q
[m/h]
-1-A
41
SP 60
p
[kPa]
SP A, SP
H
[m]
SP 60
-30
440
50 Hz
420
-28
4000
400
-26
380
3600
360
-24
340
3200
-22
320
-21
300
2800
-20
280
-19
-18
260
2400
-17
240
-16
220
2000
-15
-14
200
-13
180
1600
-12
-11
160
140
1200
120
100
800
80
60
40
0
10
p
[kPa]
20
30
40
50
10
60
15
80 Q
20
80
60
40
20
[m/h]
Q [l/s]
H
[m]
Eta
Eta
[%]
80
60
40
NPSH
20
0
0
10
20
30
40
50
42
70
60
70
80 Q
[m/h]
400
SP 60
SP A, SP
Rp 3
Rp 4
Pump type
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
60-1-A
60-1
60-2-B
60-2
60-3
60-4
60-3
60-4
60-5
60-6
60-7
60-8-B
60-8
60-9-B
60-9
60-10
60-11
60-12
60-13
60-14
60-15
60-16
60-17
60-18
60-19
60-20
60-21
60-22
60-24
60-26
60-28
60-30
Type
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 4000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MMS6
MMS6
MMS6
MMS6
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
Dimensions [mm]
B
Net
weight
[kg]
417
457
497
577
677
777
544
574
604
634
664
664
699
699
754
754
814
814
874
874
874
944
944
1312
1312
1312
1312
1270
1270
1350
1350
1350
95
95
95
95
95
95
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
144
144
144
144
192
192
192
192
192
21
23
27
31
38
45
48
54
62
67
73
75
79
82
87
90
98
100
109
111
114
124
126
169
171
174
176
239
272
293
299
305
Rp 3/Rp 4 connection
Power
[kW]
E*
1.5
2.2
3.0
4.0
5.5
7.5
5.5
7.5
9.2
11
13
13
15
15
18.5
18.5
22
22
26
26
26
30
30
37
37
37
37
45
45
55
55
55
795
835
988
1068
1281
1494
1164
1307
1450
1593
1736
1849
1884
1997
2052
2165
2338
2451
2640
2753
2866
3049
3162
3643
3756
3869
3982
4082
4555
4861
5087
5313
378
378
491
491
604
717
620
733
846
959
1072
1185
1185
1298
1298
1411
1524
1637
1766
1879
1992
2105
2218
2331
2444
2557
2670
2812
3285
3511
3737
3963
146
146
146
146
146
146
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
148
150
150
150
150
192
192
192
192
192
E**
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
151
153
153
153
153
192
192
192
192
192
43
SP A, SP
SP 60
Power curves
P2
P2
[hp] [kW]
SP 60
18
50 Hz
24
-10
16
15
20
-9
14
-9-B
13
16
-8
12
-8-B
-7
11
10
-6
12
9
-5
7
-4
8
-3
4
-2
4
-2-B
-1
2
-1-A
0
0
44
10
20
30
40
10
50
60
15
70
20
80 Q
[m/h]
Q [l/s]
SP 60
SP A, SP
P2
P2
[hp] [kW]
SP 60
54
50 Hz
72
68
50
-30
48
64
46
60
-28
44
-26
42
56
40
-24
52
38
-22
36
48
34
-21
44
32
-20
-19
30
40
-18
28
36
-17
26
-16
32
24
-15
-14
22
-13
28
20
-12
24
18
-11
16
14
0
10
20
30
40
10
50
60
15
70
20
80 Q
[m/h]
Q [l/s]
20
45
SP A, SP
SP 77
SP 77
Performance curves
p
[kPa]
H
[m]
SP 77
-9
180
50 Hz
ISO 9906:2012 Grade 3B
170
1600
-8
160
-8-B
150
1400
-7
140
130
1200
-6
120
110
1000
-5
100
90
800
-4
80
-4-B
70
600
-3
60
-3-B
50
400
-2
40
-2-B
30
200
-1
20
10
0
0
10
p
[kPa]
20
30
40
50
10
60
15
80
20
90
Q [m/h]
25
Q [l/s]
H
[m]
80
60
40
20
Eta
Eta
[%]
80
60
40
NPSH
20
0
10
20
30
40
50
60
46
70
70
80
90
Q [m/h]
SP 77
p
[kPa]
SP A, SP
H
[m]
SP 77
-22
440
50 Hz
-21
420
4000
400
-19
380
-18
3600
360
-17
340
-16
3200
320
-15
300
2800
-14
280
-13
260
2400
-12
240
-11
220
2000
-10
200
180
1600
160
140
1200
120
100
800
80
60
0
10
30
40
50
10
60
15
70
80
20
90
Q [m/h]
25
Q [l/s]
H
[m]
80
60
40
20
Eta
Eta
[%]
80
60
40
NPSH
20
0
10
20
30
40
50
60
70
80
90
Q [m/h]
p
[kPa]
20
47
SP 77
Pump type
Rp 5
125
175
200
8 x 15
48
SP A, SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
77-1
77-2-B
77-2
77-3-B
77-3
77-4-B
77-4
77-5
77-6
77-7
77-8-B
77-8
77-9
77-10
77-11
77-12
77-13
77-14
77-15
77-16
77-17
77-18
77-19
77-20
77-21
77-22
Type
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MMS6
MMS6
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
Dimensions [mm]
Rp 5 connection
Power
[kW]
E*
E**
E*
E**
5.5
5.5
7.5
9.2
11
13
15
18.5
22
26
26
30
30
37
37
45
55
55
55
63
63
63
75
75
75
92
1162
1290
1320
1478
1508
1667
1702
1885
2073
2261
2389
2459
2587
3083
3226
3313
3522
3650
3779
4047
4175
4304
4826
4954
5082
5450
618
746
746
874
874
1003
1003
1131
1259
1387
1515
1515
1643
1771
1898
2043
2172
2300
2429
2557
2685
2814
3236
3364
3492
3620
178
178
178
178
178
178
178
178
178
178
178
178
178
178
178
200
200
200
200
200
200
200
200
200
200
200
186
186
186
186
186
186
186
186
186
186
186
186
186
186
186
204
204
204
204
204
204
204
204
204
202
202
1162
1290
1320
1478
1508
1667
1702
1885
2073
2261
2389
2459
2587
3083
3210
3313
3522
3650
618
746
746
874
874
1003
1003
1131
1259
1387
1515
1515
1643
1771
1898
2043
2172
2300
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
209
209
209
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
209
209
209
Net
weight
[kg]
544
544
574
604
634
664
699
754
814
874
874
944
944
1312
1312
1270
1350
1350
1350
1490
1490
1490
1590
1590
1590
1830
138
138
138
138
138
138
138
138
138
138
138
138
138
143
143
192
192
192
192
192
192
192
192
192
192
192
55
59
63
72
75
82
86
95
105
114
118
126
129
176
179
240
259
263
266
296
300
304
334
338
342
391
SP 77
SP A, SP
Power curves
P2
P2
[hp] [kW]
SP 77
50 Hz
32
35
26
-8
24
-8-B
-7
30
22
20
-6
25
18
-5
16
20
14
-4
12
-4-B
15
10
-3
-3-B
8
10
-2
6
-2-B
5
-1
0
0
10
20
30
40
10
50
60
15
70
20
80
90
Q [m/h]
25
Q [l/s]
49
SP A, SP
SP 77
P2
P2
[hp] [kW]
SP 77
110
50 Hz
80
72
-21
68
-20
90
64
-19
60
-18
80
-17
56
-16
70
52
-15
48
-14
60
50
44
-13
40
-12
36
-11
-10
32
40
28
24
20
0
50
10
20
30
40
10
50
60
15
70
20
80
90
Q [m/h]
25
Q [l/s]
30
SP 95
SP A, SP
SP 95
Performance curves
p
[kPa]
H
[m]
SP 95
-9
50 Hz
180
1600
160
-7
140
-6
1200
120
-5
100
-5-AB
-4
800
80
-4-B
-3
60
-3-B
-3-BB
400
-2
-2-A
40
-2-BB
-1
20
0
0
20
p
[kPa]
40
60
10
80
100
20
120
30
Q [l/s]
H
[m]
80
60
40
20
Q [m/h]
Eta
Eta
[%]
80
60
40
NPSH
20
0
20
40
60
80
100
120
Q [m/h]
51
SP 95
p
[kPa]
H
[m]
SP A, SP
SP 95
-20
4000
50 Hz
-19
400
-18
-17
360
-16
3200
-15
320
-14
280
-13
-12
2400
240
-11
-10
200
1600
160
120
800
80
40
20
p
[kPa]
40
60
10
80
20
120
30
Q [m/h]
Q [l/s]
H
[m]
Eta
Eta
[%]
80
60
60
40
40
20
80
NPSH
20
0
20
40
60
80
52
100
100
120
Q [m/h]
SP 95
SP A, SP
Pump type
Rp 5
125
175
200
8 x 15
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
95-1
95-2-BB
95-2-A
95-2
95-3-BB
95-3-B
95-3
95-4-B
95-4
95-5-AB
95-5
95-6
95-7
95-8
95-9
95-10
95-11
95-12
95-13
95-14
95-15
95-16
95-17
95-18
95-19
95-20
Type
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MMS6
MMS6
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
Dimensions [mm]
Rp 5 connection
Power
[kW]
E*
E**
E*
E**
5.5
5.5
7.5
9.2
9.2
11
13
15
18.5
18.5
22
26
30
37
37
45
55
55
55
63
75
75
75
92
92
92
1162
1290
1320
1350
1478
1508
1538
1702
1757
1885
1945
2133
2331
2827
2954
3055
3264
3393
3522
3790
4019
4147
4275
4938
5066
5194
618
746
746
746
874
874
874
1003
1003
1131
1131
1259
1387
1515
1642
1785
1914
2043
2172
2300
2429
2557
2685
3108
3236
3364
178
178
178
178
178
178
178
178
178
178
178
178
178
178
178
196
196
196
196
196
196
196
196
196
196
196
186
186
186
186
186
186
186
186
186
186
186
186
186
186
186
204
204
204
204
204
204
204
204
204
204
204
1162
1290
1320
1350
1478
1508
1538
1702
1757
1885
1945
2133
2331
2827
2954
3055
3264
3393
3522
3790
618
746
746
746
874
874
874
1003
1003
1131
1131
1259
1387
1515
1642
1785
1914
2043
2172
2300
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
205
205
205
205
205
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
205
205
205
205
205
Net
weight
[kg]
544
544
574
604
604
634
664
699
754
754
814
874
944
1312
1312
1270
1350
1350
1350
1490
1590
1590
1590
1830
1830
1830
138
138
138
138
138
138
138
138
138
138
138
138
138
143
143
192
192
192
192
192
192
192
192
192
192
192
55
72
63
68
72
75
78
86
91
95
101
110
122
168
172
233
251
255
259
289
311
315
319
376
380
384
53
SP A, SP
SP 95
Power curves
P2
P2
[hp] [kW]
SP 95
50 Hz
ISO 9906:2012 Grade 3B
40
50
36
-9
32
-8
40
28
-7
24
-6
30
20
-5
-5-AB
16
-4
20
-4-B
-3
12
-3-B
-3-BB
-2
8
10
-2-A
0
0
54
20
40
10
60
80
20
100
120
30
Q [m/h]
Q [l/s]
-2-BB
-1
SP 95
P2
P2
[hp] [kW]
120
SP A, SP
SP 95
50 Hz
88
110
80
-20
76
-19
100
72
-18
68
-17
90
64
-16
60
-15
56
-14
52
-13
48
-12
80
70
60
-11
44
-10
40
50
36
32
28
0
20
40
10
60
80
20
100
120
30
Q [m/h]
Q [l/s]
40
55
SP 125
SP 125
SP A, SP
Performance curves
p
[kPa]
H
[m]
50 Hz
1600
150
-5
140
-5-A
-5-AA
130
1200
1000
120
-4
110
-4-A
-4-AA
100
-3
90
800
-3-A
80
-3-AA
70
600
-2
60
-2-A
50
400
-6-AA
160
1400
SP 125
-6-A
170
-2-AA
40
-1
30
-1-A
200
20
10
0
0
20
p
[kPa]
40
60
10
80
100
20
120
30
40
H
[m]
Q [m/h]
Q [l/s]
Eta
Eta
[%]
80
60
60
40
40
20
80
NPSH
20
0
20
40
60
80
100
56
140
120
140
Q [m/h]
SP 125
p
[kPa]
SP A, SP
H
[m]
SP 125
-17
50 Hz
500
4800
-16
480
460
-15
4400
440
-14
420
4000
400
-13
380
3600
-12
360
340
3200
-11
320
300
2800
-10
-10-A
-10-AA
-9
-9-A
-9-AA
-8
-8-A
-8-AA
-7
-7-A
-7-AA
-6
280
260
2400
240
220
2000
200
180
1600
160
140
1200
120
100
800
80
60
0
20
60
10
80
100
20
120
30
140
40
H
[m]
80
60
40
20
Q [m/h]
Q [l/s]
Eta
Eta
[%]
80
60
40
NPSH
20
0
20
40
60
80
100
120
140
Q [m/h]
p
[kPa]
40
57
SP 125
Pump type
Rp 6
SP A, SP
170
196
220
8 x 15
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
125-1-A
125-1
125-2-AA
125-2-A
125-2
125-3-AA
125-3-A
125-3
125-4-AA
125-4-A
125-4
125-5-AA
125-5-A
125-5
125-6-AA
125-6-A
125-6
125-7-AA
125-7-A
125-7
125-8-AA
125-8-A
125-8
125-9-AA
125-9-A
125-9
125-10-AA
125-10-A
125-10
125-11
125-12
125-13
125-14
125-15
125-16
125-17
Type
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MMS6
MMS6
MMS6
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 10000
MMS 10000
MMS 10000
MMS 10000
MMS 10000
MMS 10000
Dimensions [mm]
Rp 6 connection
Power
[kW]
E*
E**
E*
E**
7.5
11
13
18.5
22
22
26
30
37
37
37
45
45
55
55
55
63
63
63
75
75
75
75
92
92
92
92
92
92
110
132
132
147
147
170
170
1225
1285
1471
1561
1621
1777
1837
1907
2431
2431
2431
2545
2545
2625
2781
2781
2921
3077
3077
3177
3333
3333
3333
3729
3729
3729
3885
3885
3885
4567
4584
4740
5095
5251
5556
5712
651
651
807
807
807
963
963
963
1119
1119
1119
1275
1275
1275
1431
1431
1431
1587
1587
1587
1743
1743
1743
1899
1899
1899
2055
2055
2055
2507
2714
2870
3025
3181
3336
3492
211
211
211
211
211
211
211
211
211
211
211
213
213
213
213
213
218
218
218
218
218
218
218
218
218
218
218
218
218
218
237
237
237
237
237
237
218
218
218
218
218
218
218
218
218
218
218
218
218
218
218
218
227
227
227
227
227
227
227
227
227
227
227
227
227
227
237
237
237
237
237
237
1225
1285
1471
1561
1621
1777
1837
1907
2431
2431
2431
2545
2545
2625
2781
2781
2921
3077
3077
3177
651
651
807
807
807
963
963
963
1119
1119
1119
1275
1275
1245
1431
1431
1431
1587
1587
1587
222
222
222
222
222
222
222
222
222
222
222
223
223
223
223
223
229
229
229
229
226
226
226
226
226
226
226
226
226
226
226
226
226
226
226
226
232
232
232
232
58
Net
weight
[kg]
574
634
664
754
814
814
874
944
1312
1312
1312
1270
1270
1350
1350
1350
1490
1490
1490
1590
1590
1590
1590
1830
1830
1830
1830
1830
1830
2060
1870
1870
2070
2070
2220
2220
138
138
138
138
138
138
138
138
143
143
143
192
192
192
192
192
192
192
192
192
192
192
192
192
192
192
192
192
192
192
237
237
237
237
237
237
70
79
88
97
103
109
115
123
171
171
171
236
236
251
257
257
283
289
289
308
314
314
314
366
366
366
372
372
372
438
556
562
633
639
685
691
SP 125
SP A, SP
Power curves
P2
P2
[hp] [kW]
SP 125
50 Hz
56
70
52
-6-A
-6-AA
48
-5
60
44
-5-A
40
50
-5-AA
36
-4
-4-A
32
-4-AA
40
28
-3
24
-3-A
30
-3-AA
20
-2
16
-2-A
20
12
-2-AA
-1
10
8
-1-A
0
0
20
40
10
60
80
20
100
120
30
140
40
Q [m/h]
Q [l/s]
59
SP A, SP
SP 125
P2
P2
[hp] [kW]
SP 125
50 Hz
170
160
-17
150
-16
200
140
-15
180
130
-14
120
-13
160
110
-12
140
100
-11
120
90
-10
-10-A
-10-AA
-9
-9-A
-9-AA
-8
-8-A
-8-AA
-7
80
100
70
80
-7-A
-7-AA
-6
60
50
60
30
0
60
20
40
10
60
80
20
100
120
30
140
40
Q [m/h]
Q [l/s]
40
SP 160
SP A, SP
SP 160
Performance curves
p
[kPa]
H
[m]
-5-A
SP 160
-5-AA
150
50 Hz
1400
140
-4
130
1200
-4-A
120
-4-AA
110
1000
800
100
-3
90
-3-A
80
-3-AA
70
-2
600
60
-2-A
50
400
-2-AA
40
-1
30
-1-A
200
20
10
0
0
20
40
60
10
80
100
20
120
30
140
160
40
180
200
50
Q [m/h]
60
Q [l/s]
p
[kPa]
H
[m]
160
16
120
12
60
80
40
40
Eta
Eta
[%]
80
20
NPSH
0
0
20
40
60
80
100
120
140
160
180
200
Q [m/h]
61
SP 160
p
[kPa]
H
[m]
-15
460
-14
SP A, SP
SP 160
50 Hz
ISO 9906:2012 Grade 3B
4400
440
-13
420
4000
400
-12
380
3600
360
-11
340
3200
2800
320
-10
-10-A
300
-10-AA
-9
-9-A
-9-AA
280
260
2400
-8
-8-A
-8-AA
-7
-7-A
-7-AA
-6
-6-A
-6-AA
240
220
2000
200
180
1600
-5
160
140
1200
120
100
800
80
60
40
0
20
40
60
10
80
100
20
120
30
140
40
180
200
50
Q [m/h]
60
Q [l/s]
p
[kPa]
H
[m]
160
16
120
12
60
80
40
40
Eta
Eta
[%]
80
20
NPSH
0
0
20
40
60
80
100
120
140
62
160
160
180
200
Q [m/h]
400
SP 160
SP A, SP
Pump type
Rp 6
170
196
220
8 x 15
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
160-1-A
160-1
160-2-AA
160-2-A
160-2
160-3-AA
160-3-A
160-3
160-4-AA
160-4-A
160-4
160-5-AA
160-5-A
160-5
160-6-AA
160-6-A
160-6
160-7-AA
160-7-A
Type
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MS 6000
MMS6
MMS6
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
Dimensions [mm]
Rp 6 connection
Power
[kW]
E*
E**
E*
E**
9.2
13
18.5
22
26
30
37
37
45
45
55
55
55
63
63
75
75
75
92
1255
1315
1561
1621
1681
1907
2275
2275
2389
2389
2469
2625
2625
2765
2921
3021
3021
3177
3417
651
651
807
807
807
963
963
963
1119
1119
1119
1275
1275
1275
1431
1431
1431
1587
1587
211
211
211
211
211
211
211
211
218
218
218
218
218
218
218
218
218
218
218
218
218
218
218
218
218
218
218
227
227
227
227
227
227
227
227
227
227
227
1255
1315
1561
1621
1681
1907
2275
2275
2389
2389
2469
2625
2625
2765
2921
3021
3021
651
651
807
807
807
963
963
963
1119
1119
1119
1275
1275
1275
1431
1431
1431
222
222
222
222
222
222
222
222
229
229
229
229
229
229
229
229
229
226
226
226
226
226
226
226
226
232
232
232
232
232
232
232
232
232
Net
weight
[kg]
604
664
754
814
874
944
1312
1312
1270
1270
1350
1350
1350
1490
1490
1590
1590
1590
1830
138
138
138
138
138
138
143
143
192
192
192
192
192
192
192
192
192
192
192
76
82
97
103
109
123
165
165
230
230
245
251
251
277
283
302
302
302
354
SP 160-7
MMS 8000
92
227
1830 192
354
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
MMS
MMS
MMS
MMS
MMS
MMS
MMS
MMS
MMS
MMS
MMS
MMS
MMS
MMS
92
92
92
110
110
110
110
132
132
132
147
170
170
190
3573
3573
3573
3959
3959
3959
4411
4273
4273
4429
4784
5090
5245
5239
227
227
227
227
227
227
227
237
237
237
237
237
237
286
1830
1830
1830
2060
2060
2060
2060
1870
1870
1870
2070
2220
2220
1980
360
360
360
416
416
416
432
544
544
550
621
667
673
803
160-8-AA
160-8-A
160-8
160-9-AA
160-9-A
160-9
160-10-AA
160-10-A
160-10
160-11
160-12
160-13
160-14
160-15
8000
8000
8000
8000
8000
8000
8000
10000
10000
10000
10000
10000
10000
12000
1743
1743
1743
1899
1899
1899
2351
2403
2403
2559
2714
2870
3025
3259
218
218
218
218
218
218
218
237
237
237
237
237
237
286
192
192
192
192
192
192
192
237
237
237
237
237
237
286
63
SP 160
Power curves
SP A, SP
P2
P2
[hp] [kW]
SP 160
50 Hz
60
80
70
52
-5-AA
48
-4
60
44
-4-A
40
-4-AA
50
36
-3
32
-3-A
40
28
-3-AA
24
-2
30
20
-2-A
16
-2-AA
20
-1
12
10
-1-A
0
0
64
20
40
10
60
80
20
100
120
30
140
40
160
180
50
200
Q [m/h]
60
Q [l/s]
SP 160
P2
P2
[hp] [kW]
250
SP 160
184
50 Hz
180
240
SP A, SP
176
172
230
-15
168
164
220
160
-14
210
156
152
200
148
-13
144
190
140
-12
136
180
132
128
170
124
-11
120
160
150
116
-10
112
-10-A
108
140
104
-10-AA
-9
100
130
120
110
96
-9-A
92
-9-AA
88
-8
84
-8-A
80
-8-AA
-7
76
100
90
80
-7-A
72
-7-AA
68
-6
64
-6-A
60
-6-AA
-5
56
70
52
48
44
40
0
20
40
10
60
80
20
100
120
30
140
40
160
180
50
200
Q [m/h]
60
Q [l/s]
60
65
SP 215
SP 215
SP A, SP
Performance curves
p
[kPa]
H
[m]
SP 215
2400
240
50 Hz
-6
-6-A
220
-6-AA
2000
200
-5
-5-A
180
-5-AA
1600
-4
160
-4-A
140
1200
-4-AA
-3
120
-3-A
800
100
-3-AA
80
-2
-2-A
60
400
-2-AA
-1
40
-1-A
20
0
0
40
80
120
20
160
200
40
60
280
Q [m/h]
80
Q [l/s]
p
[kPa]
H
[m]
160
16
120
12
60
80
40
40
Eta
Eta
[%]
80
20
NPSH
0
0
40
80
120
160
200
66
240
240
280
Q [m/h]
SP 215
p
[kPa]
SP A, SP
H
[m]
SP 215
-11
440
50 Hz
ISO 9906:2012 Grade 3B
420
4000
-10
400
-10-A
380
-10-AA
360
-9
340
-9-AA
320
-8
300
-8-AA
3600
-9-A
3200
-8-A
2800
-7
280
-7-A
260
2400
-7-AA
240
220
2000
200
180
1600
160
140
1200
120
100
80
0
40
80
120
20
160
200
40
240
60
280
Q [m/h]
80
Q [l/s]
p
[kPa]
H
[m]
160
16
120
12
60
80
40
40
Eta
Eta
[%]
80
20
NPSH
0
0
40
80
120
160
200
240
280
Q [m/h]
800
67
SP 215
Pump type
Rp 6
SP A, SP
170
196
220
8 x 15
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
215-1-A
215-1
215-2-AA
215-2-A
215-2
215-3-AA
215-3-A
215-3
215-4-AA
215-4-A
215-4
215-5-AA
215-5-A
215-5
215-6-AA
215-6-A
215-6
215-7-AA
215-7-A
215-7
215-8-AA
215-8-A
215-8
215-9-AA
215-9-A
215-9
215-10-AA
215-10-A
215-10
215-11
Type
MS 6000
MS 6000
MS 6000
MMS6
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 8000
MMS 10000
MMS 10000
MMS 10000
MMS 10000
MMS 10000
MMS 10000
MMS 10000
MMS 10000
MMS 10000
MMS 12000
MMS 12000
MMS 12000
MMS 12000
Dimensions [mm]
Rp 6 connection
Power
[kW]
E*
E**
E*
E**
15
18.5
30
37
45
55
55
63
75
75
75
92
92
92
110
110
110
132
132
132
147
147
147
170
170
170
190
190
190
220
1489
1544
1910
2278
2236
2492
2492
2632
2908
2908
2908
3324
3324
3554
3730
3730
3730
4016
4016
4016
4392
4392
4392
4718
4718
4718
4654
4654
4654
4990
790
790
966
966
966
1142
1142
1142
1318
1318
1318
1494
1494
1494
1670
1670
1670
2146
2146
2146
2322
2322
2322
2498
2498
2498
2674
2674
2674
2850
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
276
276
276
276
276
276
286
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
276
276
276
276
276
276
286
1489
1544
1910
2278
2236
2492
2492
2632
2908
2908
2908
3324
3324
3554
3730
3730
3730
790
790
966
966
966
1142
1142
1142
1318
1318
1318
1494
1494
1494
1670
1670
1670
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
241
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
247
68
Net
weight
[kg]
699
754
944
1312
1270
1350
1350
1490
1590
1590
1590
1830
1830
1830
2060
2060
2060
1870
1870
1870
2070
2070
2070
2220
2220
2220
1980
1980
1980
2140
138
138
138
143
192
192
192
192
192
192
192
192
192
192
192
192
192
237
237
237
237
237
237
237
237
237
286
286
286
286
92
97
127
169
228
253
253
279
308
308
308
364
364
364
424
424
424
547
547
547
622
622
622
672
672
672
793
793
793
853
SP 215
SP A, SP
Power curves
P2
P2
[hp] [kW]
SP 215
50 Hz
112
140
104
-6
-6-A
96
-6-AA
120
88
-5
-5-A
80
-5-AA
100
72
-4
-4-A
64
-4-AA
80
56
-3
48
-3-A
60
-3-AA
40
-2
32
40
-2-A
24
20
-2-AA
-1
16
-1-A
0
0
40
80
20
120
160
40
200
240
60
280
Q [m/h]
80
Q [l/s]
69
SP A, SP
SP 215
P2
P2
[hp] [kW]
SP 215
50 Hz
208
280
260
192
184
240
-10
176
-10-A
168
-10-AA
220
160
-9
-9-A
152
-9-AA
200
144
-8
136
-8-A
180
-8-AA
128
-7
120
160
-7-A
-7-AA
112
140
104
96
88
80
0
70
40
80
20
120
160
40
200
240
60
280
Q [m/h]
80
Q [l/s]
120
SP A, SP
Electrical data
5. Electrical data
1 x 230 V, submersible motors
Electrical data
Dimensions
Motor
Power factor
Full-load Motor efficiency [%]
current
Power
Cos Cos Cos
Size
50 % 75 % 100 %
In [A]
[kW]
50 %
75 % 100 %
Type
Ist
In
MS 402
4"
0.37
3.95
48.0
54.0
57.0
0.58
0.68
0.77
3.4*
SA-SPM 2
16 F, 400 V, 50 Hz
256
6.8
MS 402
4"
0.55
5.80
49.5
56.5
59.5
0.52
0.65
0.74
3.5*
SA-SPM 2
20 F, 400 V, 50 Hz
291
8.2
MS 402
4"
0.75
7.45
52.0
58.0
60.0
0.57
0.69
0.79
3.6*
SA-SPM 2
30 F, 400 V, 50 Hz
306
8.9
MS 402
4"
1.1
7.30
62.0
69.5
72.5
0.99
0.99
0.99
4.3*
SA-SPM 3
40 F, 400 V, 50 Hz
346
10.5
MS 402
4"
1.5
10.2
56.5
66.5
71.0
0.91
0.96
0.98
3.9
SA-SPM 3
346
11.0
MS 4000 (R)
4"
2.2
14.0
67.0
73.0
75.0
0.91
0.94
0.96
4.4
SA-SPM 3
576
21.0
MS 402 2-wire motors incorporate motor protection and can therefore be connected directly to the mains.
Dimensions
Power factor
100 %
Cos 50 %
Cos 75 %
Cos 100 %
Ist
In
59.5
64.0
0.44
0.55
0.64
3.7
226
5.5
57.0
64.0
0.42
0.52
0.64
3.5
241
6.3
64.0
69.5
73.0
0.50
0.62
0.72
4.6
276
7.7
3.35
66.8
71.1
72.9
0.66
0.76
0.82
5.1
401
13.0
1.1
6.20
62.5
69.0
73.0
0.47
0.59
0.72
4.6
306
8.9
1.1
5.00
69.1
73.2
75.0
0.57
0.70
0.78
5.2
416
14.0
4"
1.5
7.65
68.0
73.0
75.0
0.50
0.64
0.75
5.0
346
10.5
4"
1.5
7.40
66.6
71.4
72.9
0.53
0.66
0.74
4.5
416
14.0
4"
2.2
10.0
72.5
75.5
76.0
0.56
0.71
0.82
4.7
346
11.9
MS 4000 (R)
4"
2.2
11.6
64.5
70.8
73.3
0.44
0.58
0.69
4.2
456
16.0
MS 4000 (R)
4"
3.0
14.6
67.5
72.8
74.6
0.48
0.62
0.73
4.4
496
17.0
MS 4000 (R)
4"
4.0
17.6
73.9
77.4
77.9
0.52
0.67
0.77
4.9
576
21.0
MS 4000 (R)
4"
5.5
24.2
76.0
78.8
79.6
0.51
0.66
0.76
4.9
676
26.0
MS 6000 (R)
6"
5.5
24.8
77.0
79.0
80.0
0.51
0.64
0.73
4.5
544
35.5
MS 6000 (R)
6"
7.5
32.0
79.0
82.0
82.0
0.55
0.68
0.77
4.6
574
37.0
MS 6000 (R)
6"
9.2
39.5
77.0
80.0
80.0
0.56
0.70
0.78
4.8
604
42.5
MS 6000 (R)
6"
11
45.0
81.0
82.5
82.5
0.60
0.72
0.79
4.8
634
45.5
MS 6000 (R)
6"
13
54.5
81.0
82.5
82.5
0.58
0.71
0.78
4.8
664
48.5
MS 6000 (R)
6"
15
62.0
82.0
83.5
83.5
0.59
0.71
0.78
5.2
699
52.5
MS 6000 (R)
6"
18.5
76.5
82.5
84.5
84.0
0.56
0.69
0.77
5.3
754
58.0
MS 6000 (R)
6"
22
87.5
84.5
85.0
84.0
0.61
0.74
0.81
5.2
814
64.0
MS 6000 (R)
6"
26
104
83.5
84.0
83.5
0.61
0.73
0.81
5.0
874
69.5
MS 6000 (R)
6"
30
120
83.0
84.0
83.0
0.59
0.72
0.80
5.0
944
77.5
Full-load current
In [A]
Size
Power
[kW]
MS 402
4"
0.37
2.55
51.0
MS 402
4"
0.55
4.00
48.5
MS 402
4"
0.75
4.20
MS 4000R
4"
0.75
MS 402
4"
MS 4000R
4"
MS 402
MS 4000R
MS 402
Type
50 % 75 %
Length Weight
[mm]
[kg]
71
SP A, SP
Electrical data
Type
Full-load current
In [A]
Dimensions
Power factor
Ist
In
Length Weight
[mm]
[kg]
MMS6 (N, R)
6"
5.5
25.0
71
75
76
0.61
0.72
0.78
3.5
807
50
MMS6 (N, R)
6"
7.5
33.5
72
76
77
0.59
0.71
0.78
3.5
837
53
MMS6 (N, R)
6"
9.2
40.5
74
77
78
0.59
0.71
0.78
3.6
867
55
MMS6 (N, R)
6"
11
50.0
74
78
79
0.53
0.66
0.74
3.8
897
60
MMS6 (N, R)
6"
13
56.0
77
80
80
0.57
0.69
0.77
3.9
927
65
MMS6 (N, R)
6"
15
62.5
79
82
82
0.58
0.71
0.79
4.3
997
77
MMS6 (N, R)
6"
18.5
75.0
80
82
82
0.61
0.75
0.81
4.2
1057
83
MMS6 (N, R)
6"
22
87.0
82
84
83
0.61
0.74
0.81
5.3
1087
95
MMS6 (N, R)
6"
26
106
81
83
83
0.57
0.7
0.78
5.6
1157
105
MMS6 (N, R)
6"
30
118
82
83
82
0.63
0.76
0.82
4.8
1212
110
MMS6 (N, R)
6"
37
148
82
84
83
0.59
0.72
0.81
5.4
1312
120
8"
22
82.5
80
84
84
0.71
0.80
0.84
5.3
1010
126
8"
26
95.5
81
84
84
0.76
0.83
0.86
5.1
1050
134
8"
30
110
83
85
86
0.71
0.80
0.84
5.7
1110
146
8"
37
134
83
86
86
0.73
0.82
0.85
5.7
1160
156
8"
45
168
84
87
88
0.62
0.74
0.81
6.0
1270
177
8"
55
214
84
87
88
0.57
0.70
0.77
5.9
1350
192
8"
63
210
87
89
89
0.81
0.87
0.90
5.7
1490
218
10"
75
270
84
86
86
0.72
0.81
0.85
5.4
1500
330
10"
92
345
83
85
86
0.65
0.77
0.82
5.6
1690
385
10"
110
385
85
86
86
0.80
0.86
0.88
5.7
1870
435
72
Power
Size
[kW]
Full-load current
In [A]
Dimensions
Power factor
100 %
Cos 50 %
Cos 75 %
Cos 100 %
Ist
In
Length
[mm]
Weight
[kg]
MS 402
4"
0.37
1.40
51.0
59.5
64.0
0.44
0.55
0.64
3.7
226
5.5
MS 402
4"
0.55
2.20
48.5
57.0
64.0
0.42
0.52
0.64
3.5
241
6.3
MS 402
4"
0.75
2.30
64.0
69.5
73.0
0.50
0.62
0.72
4.7
276
7.7
MS 4000R
4"
0.75
1.84
68.1
71.6
72.8
0.69
0.79
0.84
4.9
401
13.0
MS 402
4"
1.1
3.40
62.5
69.0
73.0
0.47
0.59
0.72
4.6
306
8.9
MS 4000R
4"
1.1
2.75
70.3
74.0
74.4
0.62
0.74
0.82
5.1
416
14.0
MS 402
4"
1.5
4.20
68.0
73.0
75.0
0.50
0.64
0.75
5.0
346
10.5
MS 4000R
4"
1.5
4.00
69.1
72.7
73.7
0.55
0.69
0.78
4.3
416
14.0
MS 402
4"
2.2
5.50
72.5
75.5
76.0
0.56
0.71
0.82
4.7
346
11.9
MS 4000 (R)
4"
2.2
6.05
67.9
73.1
74.5
0.49
0.63
0.74
4.5
456
16.0
MS 4000 (R)
4"
3.0
7.85
71.5
74.5
75.2
0.53
0.67
0.77
4.5
496
17.0
MS 4000 (R)
4"
4.0
9.60
77.3
78.4
78.0
0.57
0.71
0.80
4.8
576
21.0
MS 4000 (R)
4"
5.5
13.0
78.5
80.1
79.8
0.57
0.72
0.81
4.9
676
26.0
MS 4000 (R)
4"
7.5
18.8
75.2
78.2
78.2
0.52
0.67
0.78
4.5
776
31.0
MS 6000 (R)
6"
5.5
13.6
78.0
80.0
80.5
0.55
0.67
0.77
4.4
544
35.5
MS 6000 (R)
6"
7.5
17.6
81.5
82.0
82.0
0.60
0.73
0.80
4.3
574
37.0
MS 6000 (R)
6"
9.2
21.8
78.0
80.0
79.5
0.61
0.73
0.81
4.6
604
42.5
MS 6000 (R)
6"
11
24.8
82.0
83.0
82.5
0.65
0.77
0.83
4.7
634
45.5
MS 6000 (R)
6"
13
30.0
82.5
83.5
82.0
0.62
0.74
0.81
4.6
664
48.5
MS 6000 (R)
6"
15
34.0
82.0
83.5
83.5
0.64
0.76
0.82
5.0
699
52.5
MS 6000 (R)
6"
18.5
42.0
83.5
84.5
83.5
0.62
0.73
0.81
5.1
754
58.0
MS 6000 (R)
6"
22
48.0
84.5
85.0
83.5
0.67
0.77
0.84
5.0
814
64.0
MS 6000 (R)
6"
26
57.0
84.5
85.0
84.0
0.66
0.77
0.84
4.9
874
69.5
MS 6000 (R)
6"
30
66.5
84.5
85.0
84.0
0.64
0.77
0.83
4.9
944
77.5
SP A, SP
Electrical data
Motor
Type
Power
Size
[kW]
Full-load current
In [A]
Dimensions
Electrical data
100 %
Cos 50 %
Cos 75 %
Cos 100 %
Ist
In
Length
[mm]
Weight
[kg]
MS 4000I (R)
4"
2.2
5.9
72.5
76.5
77.0
0.59
0.71
0.80
5.0
496
17.0
MS 4000I (R)
4"
3.0
7.5
75.0
79.0
80.0
0.58
0.71
0.79
5.4
576
21.0
MS 4000I (R)
4"
4.0
9.75
75.5
79.5
79.5
0.67
0.78
0.84
5.3
676
26.0
MS 4000I (R)
4"
5.5
14.4
77.5
79.6
79.8
0.55
0.69
0.79
5.0
776
42.5
MS 6000I (R)
6"
5.5
13.2
75.0
79.0
80.0
0.63
0.74
0.80
6.0
604
42.5
MS 6000I (R)
6"
7.5
17.0
79.5
81.0
81.5
0.71
0.80
0.84
4.9
634
45.5
MS 6000I (R)
6"
9.2
20.2
80.0
82.5
82.5
0.72
0.80
0.85
5.5
664
48.5
MS 6000I (R)
6"
11
24.2
82.0
83.0
83.0
0.74
0.83
0.86
5.0
699
52.5
MS 6000I (R)
6"
13
28.5
82.0
83.5
84.0
0.71
0.80
0.84
5.4
754
58.0
MS 6000I (R)
6"
15
33.0
82.0
83.5
84.0
0.68
0.79
0.84
5.9
814
64.0
MS 6000I (R)
6"
18.5
39.5
84.0
85.5
85.0
0.71
0.80
0.85
5.8
874
69.5
MS 6000I (R)
6"
22
48.0
83.5
84.5
84.5
0.71
0.80
0.85
5.6
944
77.5
73
5
Electrical data
74
SP A, SP
Power
Size
[kW]
Dimensions
Ist
In
Length Weight
[mm]
[kg]
MMS6 (N, R)
6"
5.5
14.4
71
75
76
0.60
0.71
0.77
3.5
807
50
MMS6 (N, R)
6"
7.5
19.2
72
76
77
0.59
0.71
0.78
3.6
837
53
MMS6 (N, R)
6"
9.2
22.8
75
78
78
0.61
0.73
0.79
3.5
867
55
MMS6 (N, R)
6"
11
27.5
74
78
78
0.58
0.71
0.79
3.7
897
60
MMS6 (N, R)
6"
13
32.0
77
79
79
0.63
0.75
0.79
3.8
927
65
MMS6 (N, R)
6"
15
36.5
76
79
79
0.59
0.72
0.80
4.2
997
77
MMS6 (N, R)
6"
18.5
43.5
79
81
81
0.60
0.72
0.80
4.5
1057
83
MMS6 (N, R)
6"
22
51.5
81
83
83
0.57
0.70
0.79
5.5
1087
95
MMS6 (N, R)
6"
26
61.0
81
83
83
0.57
0.70
0.78
5.7
1157
105
MMS6 (N, R)
6"
30
68.2
83
84
84
0.61
0.73
0.81
5.0
1212
110
MMS6 (N, R)
6"
37
84.5
82
84
83
0.60
0.73
0.81
5.1
1312
120
8"
22
48.0
80
82
82
0.72
0.81
0.84
5.3
1010
126
8"
26
56.5
80
82
82
0.76
0.83
0.85
5.1
1050
134
8"
30
64.0
82
84
84
0.74
0.82
0.85
5.7
1110
146
8"
37
78.5
82
84
84
0.74
0.82
0.85
5.7
1160
156
8"
45
96.5
84
86
86
0.65
0.76
0.82
6.0
1270
177
8"
55
114
84
86
86
0.72
0.81
0.85
5.9
1350
192
8"
63
132
85
87
87
0.66
0.78
0.83
5.7
1490
218
8"
75
152
86
87
87
0.71
0.82
0.86
5.8
1590
237
8"
92
186
87
88
87
0.72
0.82
0.86
5.9
1830
283
8"
110
224
86
87
87
0.73
0.83
0.87
5.8
2060
333
10"
75
156
84
86
87
0.70
0.80
0.84
5.4
1400
280
10"
92
194
84
87
87
0.67
0.78
0.82
5.6
1500
330
10"
110
228
85
87
88
0.70
0.79
0.84
5.7
1690
385
10"
132
270
85
88
88
0.71
0.81
0.84
5.7
1870
435
10"
147
315
84
87
87
0.64
0.75
0.81
6.2
2070
500
10"
170
365
84
86
87
0.64
0.75
0.81
6.0
2220
540
10"
190
425
83
86
87
0.60
0.72
0.79
5.9
2400
580
12"
147
305
84
87
88
0.66
0.77
0.83
6.2
1790
565
12"
170
345
85
87
88
0.69
0.79
0.85
6.1
1880
605
12"
190
390
85
87
88
0.68
0.79
0.84
6.2
1980
650
12"
220
445
85
87
88
0.69
0.80
0.85
6.1
2140
700
12"
250
505
85
87
88
0.69
0.80
0.85
5.9
2290
775
SP A, SP
Electrical data
Motor
Power factor
100 %
Cos 50 %
Cos 75 %
Cos 100 %
72.7
73.7
0.55
0.69
0.78
4.7
401
13.0
74.0
74.4
0.62
0.74
0.82
5.0
416
14.0
72.7
73.7
0.55
0.69
0.78
4.4
416
14.0
67.9
73.1
74.5
0.49
0.63
0.74
4.3
456
16.0
6.3
71.5
74.5
75.2
0.53
0.67
0.77
4.6
496
17.0
4.0
7.7
77.3
78.4
78.0
0.57
0.71
0.81
4.8
576
21.0
4"
5.5
10.4
78.5
80.1
79.8
0.57
0.72
0.81
4.9
676
26.0
4"
7.5
15.0
75.2
78.2
78.2
0.52
0.67
0.78
4.5
776
31.0
Size
Power
[kW]
MS 4000R
4"
0.75
1.5
69.1
MS 4000R
4"
1.1
2.2
70.3
MS 4000R
4"
1.5
3.2
69.1
MS 4000 (R)
4"
2.2
4.9
MS 4000 (R)
4"
3.0
MS 4000 (R)
4"
MS 4000 (R)
MS 4000 (R)
Type
Dimensions
Ist
In
Full-load current
In [A]
50 % 75 %
Electrical data
Length
[mm]
Weight
[kg]
MS 6000 (R)
6"
5.5
10.8
78.0
80.0
80.5
0.56
0.67
0.77
4.4
544
35.5
MS 6000 (R)
6"
7.5
14.0
81.0
82.5
82.5
0.60
0.72
0.8
4.5
574
37.0
MS 6000 (R)
6"
9.2
17.4
78.0
80.0
80.0
0.62
0.73
0.81
4.6
604
42.5
MS 6000 (R)
6"
11
19.8
82.0
83.5
82.0
0.65
0.77
0.83
4.7
634
45.5
MS 6000 (R)
6"
13
24.0
82.5
83.5
82.5
0.62
0.74
0.81
4.6
664
68.5
MS 6000 (R)
6"
15
27.0
82.0
83.0
83.0
0.65
0.76
0.82
5.0
699
52.5
MS 6000 (R)
6"
18.5
33.5
83.5
84.5
84.0
0.61
0.73
0.81
5.1
754
58.0
MS 6000 (R)
6"
22
38.5
84.5
85.0
84.0
0.67
0.77
0.84
5.0
814
64.0
MS 6000 (R)
6"
26
45.5
84.5
85.0
84.0
0.66
0.77
0.84
4.9
874
69.5
MS 6000 (R)
6"
30
53.0
85.0
84.5
83.5
0.64
0.76
0.83
4.9
945
77.5
Full-load current
In [A]
Dimensions
Power factor
Ist
In
Length
[mm]
Weight
[kg]
Size
Power
[kW]
MS 4000I (R)
4"
2.2
4.7
72.5
76.5
77.0
0.59
0.71
0.80
4.9
496
17.0
MS 4000I (R)
4"
3.0
6.2
75.0
79.0
80.0
0.58
0.71
0.79
5.4
576
21.0
MS 4000I (R)
4"
4.0
7.8
75.5
79.5
79.5
0.67
0.78
0.84
5.2
676
26.0
MS 4000I (R)
4"
5.5
11.6
77.0
79.5
80.0
0.55
0.68
0.78
5.0
776
31.0
MS 6000I (R)
6"
5.5
10.6
75.0
78.5
80.0
0.63
0.74
0.80
6.0
604
42.5
MS 6000I (R)
6"
7.5
13.6
79.5
81.0
81.5
0.71
0.80
0.84
4.9
634
45.5
MS 6000I (R)
6"
9.2
16.2
80.0
83.0
83.0
0.72
0.81
0.84
5.5
664
48.5
MS 6000I (R)
6"
11
19.4
82.0
83.5
83.5
0.74
0.82
0.86
5.0
699
52.5
MS 6000I (R)
6"
13
22.8
82.5
83.5
84.0
0.71
0.80
0.84
5.4
754
58.0
MS 6000I (R)
6"
15
26.4
82.0
84.0
84.5
0.71
0.79
0.84
5.9
814
64.0
MS 6000I (R)
6"
18.5
31.5
84.5
85.5
85.0
0.71
0.81
0.85
5.8
874
69.5
MS 6000I (R)
6"
22
38.5
84.0
84.5
84.5
0.71
0.80
0.85
5.6
944
77.5
Type
50 % 75 %
100 %
Cos 50 %
Cos 75 %
Cos 100 %
75
5
Electrical data
76
SP A, SP
Power
Size
[kW]
Full-load current
In [A]
Dimensions
Power factor
Ist
In
Length Weight
[mm]
[kg]
MMS6 (N, R)
6"
9.2
18.6
72
75
75
0.61
0.74
0.81
3.5
867
MMS6 (N, R)
6"
11
21.8
74
77
76
0.64
0.75
0.81
3.5
897
55
60
MMS6 (N, R)
6"
13
25.0
76
78
78
0.62
0.75
0.81
3.7
927
65
MMS6 (N, R)
6"
15
28.0
77
80
79
0.65
0.77
0.82
3.9
997
77
MMS6 (N, R)
6"
18.5
34.5
78
80
79
0.65
0.77
0.83
4.0
1057
83
MMS6 (N, R)
6"
22
39.5
82
82
80
0.69
0.80
0.84
4.8
1087
95
MMS6 (N, R)
6"
26
47.0
81
82
80
0.67
0.79
0.84
5.0
1157
105
MMS6 (N, R)
6"
30
54.5
80
81
79
0.67
0.79
0.84
4.5
1212
110
MMS6 (N, R)
6"
37
66.5
81
82
80
0.66
0.78
0.85
5.1
1312
120
8"
22
37.5
81
83
83
0.79
0.85
0.87
4.7
1010
126
8"
26
44.0
81
84
83
0.80
0.85
0.86
4.8
1050
134
8"
30
49.5
83
85
85
0.78
0.85
0.86
5.6
1110
146
8"
37
60.5
84
85
85
0.82
0.87
0.87
5.6
1160
156
8"
45
72.0
85
87
87
0.73
0.82
0.86
6.2
1270
177
8"
55
88.5
86
88
88
0.71
0.81
0.86
6.1
1350
192
8"
63
96.5
87
89
88
0.82
0.88
0.90
6.1
1490
218
8"
75
114
88
89
88
0.85
0.89
0.90
5.6
1590
237
8"
92
142
88
87
88
0.81
0.87
0.89
5.3
1830
283
8"
110
182
86
88
88
0.67
0.78
0.84
5.3
2060
333
10"
75
122
85
87
87
0.77
0.84
0.86
5.3
1400
280
10"
92
150
85
87
87
0.74
0.82
0.85
5.3
1500
330
10"
110
178
85
87
88
0.76
0.84
0.86
5.4
1690
385
10"
132
210
86
88
87
0.82
0.87
0.88
5.0
1870
435
10"
147
236
85
88
88
0.74
0.83
0.86
5.8
2070
500
10"
170
270
86
88
88
0.78
0.85
0.87
5.4
2220
540
10"
190
305
86
88
87
0.80
0.86
0.87
5.3
2400
580
12"
147
218
86
89
90
0.80
0.88
0.91
6.9
1790
565
12"
170
265
87
89
90
0.74
0.82
0.86
6.0
1880
605
12"
190
220
88
90
91
0.85
0.91
0.93
7.8
1980
650
12"
220
335
88
90
90
0.79
0.86
0.88
5.8
2140
700
12"
250
375
87
90
91
0.75
0.85
0.89
6.3
2290
775
SP A, SP
Accessories
6. Accessories
CUE frequency converter
The Grundfos CUE is a series of external frequency
converters designed for speed control of a wide range
of Grundfos pumps.
When a CUE is installed, the motor requires no further
motor protection.
The CUE offers quick and easy set-up and
commissioning compared to a standard frequency
converter because of the start-up guide. Simply key in
application-specific variables such as motor data,
pump family, control function (for example constant
pressure), sensor type and setpoint, and the CUE will
automatically set all necessary parameters.
The CUE enables gentle pumping and thereby protects
the water reservoir and the rest of the distribution
system, as water hammer can be avoided by adjusting
ramp times up and down.
Overview of the CUE range
Power range [kW]
0.55
0.75
1.1
7.5
11
45
GrA4404 3407
Supply voltage
[V]
250
3 x 525-690
3 x 525-600
3 x 380-500
3 x 200-240
1 x 200-240
1 x 200-240
1.1 - 7.5
C1
3 x 200-240
0.75 - 45
C1
0.55 - 90
C1
110 - 250
C2
3 x 525-600
0.75 - 7.5
C3
3 x 525-690
11 - 25
C3
Voltage
[V]
3 x 380-500
Application
Domestic
Domestic/
industry
Industry
Functions
The CUE has a wide range of pump-specific functions,
such as:
constant pressure
constant level
constant flow rate
constant temperature
constant curve.
CUE features
Start-up guide
The CUE incorporates an innovative start-up guide
for the general setting of the CUE including the
setting of the correct direction of rotation.
The start-up guide is started the first time the CUE
is connected to the power supply.
Check of direction of rotation.
Duty/standby operation.
Dry-running protection.
Low-flow stop function.
Accessories for the CUE
Grundfos offers various accessories for the CUE.
77
SP A, SP
CUE
Mains cable,
unscreened
CUE
Typical shaft
power, P2
dU/dt filter
Sine-wave
filter
Up to 7.5 kW
0-300 m
11 kW and up
0-150 m
150-300 m
78
Screened
cable
cable
Drop cable,
unscreened
Pump type
Filter
Output filters
Mains cable,
unscreened
Filter
Screened
cable
cable
Screened
cable
Connection box
Accessories
SP A, SP
Issues to be considered
Explanation
Min. 30 Hz.
Use a 60 Hz motor for larger
range.
Accessories
TM055456 3712
79
SP A, SP
Accessories
Benefits
96095275
96095276
96095278
Product
Product number
MP 204
96079927
R100
96615297
Single-turn transformers
Current transformer ratio: 200:5, Imax. = 120 A
96095274
96095277
IP20
Ambient temperature
-20 C to +60 C
99 %
Voltage range
100-480 VAC
Current range
3-999 A
Frequency
50 to 60 Hz
1-45
0.1 to 30 s
Voltage variation
- 25 % / + 15 % of rated voltage
Approvals
Marking
Consumption
Max. 5 W
Plastic type
Black PC/ABS
Measuring
range
Accuracy
Resolution
Current without
external current
transformers
3-120 A
1%
0.1 A
Current with
external current
transformers
120-999 A
1%
1A
Phase-to-phase
voltage
80-610 VAC
1%
1V
0.5 Hz
Frequency
47-63 Hz
1%
Power
0-1 MW
2%
1W
Power factor
0 - 0.99
2%
0.01
5%
1 kWh
Energy consumption
80
SP A, SP
Product
Description
Accessories
IO 112 module
Product number
The IO 112 interface has three inputs for measured values, one potentiometer
for setting of limits and indicator lights indicating the following:
measured value of the input
value of the limit set
alarm source
pump status.
96651601
Electrical data
Supply voltage: 24 VAC 10 %, 50/60 Hz or 24 VDC 10 %.
Supply current: Min. 2.4 A, max. 8 A.
Power consumption: Max. 5 W.
Ambient temperature: -25 C to +65 C.
Enclosure class: IP20.
Control MP 204
Product
Description
Product number
The Control MP 204 control cabinets are supplied with all necessary
components. Three types of control cabinets are available, depending on
functions and starting method.
The control cabinets are designed for installation in a control cabinet for
outdoor use.
The Control MP 204 control cabinets have a built-in main switch and a thermal
magnetic circuit breaker.
Functions:
Digital input
Float switch or pressure relay (if no IO 112 is used).
Analog input
Too high motor temperature (Tempcon)
thermistor/PTC, pump
pressure sensor, 4-20 mA (with IO 112).
Relay output
Pump alarm.
Communication
Grundfos Remote Management.
GSM/GPRS
(IO 112 not supported)
Modbus RTU wired
(IO 112 not supported)
Profibus DP
(IO 112 not supported).
Protection
Protects the pump against short-circuit.
Consult WebCAPS on
www.grundfos.com for product
selection.
81
SP A, SP
GrA6118 3908
Accessories
Fieldbus protocol
CIU 100
LonWorks
CIU 150
Profibus DP
CIU 200
Modbus RTU
CIU 250
GSM/GPRS
CIU 270/271*
GRM
CIU 300
BACnet MS/TP
CUE
MP 204
Product numbers
CIU unit
Fieldbus protocol
CIU 100
LonWorks
96753735
CIU 150
Profibus DP
96753081
CIU 200
Modbus RTU
96753082
CIU 250*
GSM/GPRS
96787106
CIU 270*
GRM
98176136
CIU 271*
GRM
96898819
CIU 300
BACnet MS/TP
96893769
Product number
Product number
97631956
97631957
82
SP A, SP
Accessories
Connecting pieces
The tables below show the range of connecting pieces for connection of thread-to-flange and thread-to-thread.
A
B
SP 17
Rp 2 1/2
SP 30
Rp 3
SP 46
SP 60
Rp 3
Rp 4
SP 77
SP 95
Rp 5
SP 125
SP 160
SP 215
Rp 6
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
2
2
2
3
3
3
3
3
3
4
5
5
5
6
6
6
6
1/2 DN 50 PN 16/40
1/2 DN 65 PN 16/40
1/2 DN 80 PN 16/40
DN 65 PN 16/40
DN 80 PN 16/40
DN 100 PN 16/40
DN 65 PN 16/40
DN 80 PN 16/40
DN 100 PN 16/40
DN 100 PN 16/40
DN 100 PN 16/40
DN 125 PN 16/40
DN 150 PN 16/40
DN 125 PN 16/40
DN 150 PN 16/40
DN 200 PN 16
DN 200 PN 40
R 2 1/2
R 2 1/2
R 2 1/2
R3 3
R3
R3
R3
R3
R3
R4
R5
R5
R5
R6
R6
R6
R6
Product number
Dimensions
[mm]
C
125
65 40
145
71 30
160
82.5 40
145
71 30
160
82.5 40
180/190 100 40
145
71 30
160
82.5 40
180/190 100 40
180/190 100 40
180/190 82 35
210/220 99 37
240/250 115 36
210/220 99 36
240/250 114 36
295
134 36
320
151 36
v1
19
19
19
19
19
19/23
19
19
19/23
19/23
19/23
19/28
23/28
19/28
23/28
23
31
165
185
200
185
200
235
185
200
235
235
235
270
300
270
300
340
375
170
170
170
170
170
170
170
170
170
180
195
195
195
195
195
195
200
60
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
15
15
v2
n
EN 1.4308
EN 1.4517
120125
120126
120127
130187
130188
130189
130187
130188
130189
140071
160148
160149
160150
170159
170160
170161
170162
120911
120910
120909
130920
130921
130922
130920
130921
130922
140577
160646
160647
160648
170596
170597
170598
170599
90 4
45 8
45 8
45 8
45 8
45 8
45 8
45 8
45 8
45 8
45 8
45 8
45 8
45 8
45 8
30 12
30 12
Thread-to-thread
L
Fig. 23 Dimensional sketch and photo of the connecting piece thread-to-thread
Dimensions
Type
SP 77
SP 95
SP 125
SP 160
SP 215
Pump
outlet
Rp 5
5" NPT
Rp 6
6" NPT
Connecting piece
R 5 Rp 4
R 5 Rp 6
5" NPT 4" NPT
5" NPT 6" NPT
R 6 Rp 5
6" NPT 5" NPT
Thread-to-thread
Product number
L [mm]
EN 1.4301
EN 1.4401
EN 1.4539
R5
R5
5" NPT
5" NPT
Rp 4
Rp 6
4" NPT
6" NPT
121
150
121
150
190063
190069
190064
190070
190585
190591
190586
190592
96917293
96917296
-
R6
Rp 5
150
200130
200640
200971
6" NPT
5" NPT
150
200135
200645
83
SP A, SP
Product
Description
Accessories
Version
N-version
R-version
799901
799955
799902
799918
Product
84
Motor cable
Flat cable
Flat cable
Flat cable
[mm2]
Number of
leads
1.5 - 6.0
1.5 - 4.0
6 - 10
10 - 16
16 - 25
3
4
Product
number
116251
116252
116255
Single lead
10 - 70
Single lead
35 - 120
116256
Screw-shrinking
70 - 240
96637279
Screw-shrinking
19 - 95
6 - 35
35 - 185
96828296
96636867
1
96636868
96637278
6
Version
Product
Description
Number of
leads
10 - 50
96637318
10 - 50
96637330
16 - 70
96637331
16 - 70
96637332
1.5 - 6.0
116253
10 - 25
116254
1.5 - 4.0
116257
6 - 16
116258
Reducer-shrinking
Product
number
[mm2]
Motor cable
Accessories
SP A, SP
Description
Product
Mastik for cable termination kit, type KM, for cables with separate earth, 48 pcs.
96871223
Product
Version
Outer cable
diameter
[mm]
M0
40
6 - 15
ID8903
M1
46
9 - 23
ID8904
M2
52
17 - 31
ID8905
M3
77
26 - 44
ID8906
M4
97
29 - 55
91070700
Number of
connectors
Product
number
GrA8251 2209
Cross-section of
leads
[mm2]
Accessories for cable kits M0 to M4.
Screw connectors only.
Product
number
Type
Diameter of
cable joint
[mm]
6-25
96626021
16-95
96626022
35-185
70-240
96626023
96626028
85
SP A, SP
Accessories
Description
Number of
leads and
nominal
cross-section
[mm2]
Outer cable
diameter
min./max.
[mm]
Weight
[kg/m]
Product
number
1 x 25
12.5 / 16.5
0.410
ID4072
1 x 35
14.0 / 18.5
0.560
ID4073
1 x 50
16.5 / 21.0
0.740
ID4074
1 x 70
18.5 / 23.5
1.000
ID4075
1 x 95
21.0 / 26.5
1.300
ID4076
1 x 120
23.5 / 28.5
1.650
ID4077
1 x 150
26.0 / 31.5
2.000
ID4078
1 x 185
27.5 / 34.5
2.500
ID4079
4G1.5
10.5 / 13.5
0.190
ID4063
4G2.5
12.5 / 15.5
0.280
ID4064
4G4.0
14.5 / 18.0
0.390
ID4065
4G6.0
16.5 / 22.0
0.520
ID4066
4G10
22.5 / 24.5
0.950
ID4067
4G16
26.5 / 28.5
1.400
ID4068
4G25
32.0 / 34.0
1.950
ID4069
4G35
33.0 / 42.5
2.700
96432949
4G50
38.0 / 48.5
3.600
96432950
4G70
43.0 / 54.5
4.900
96432951
Cable clips
Description
Product
86
Product number
115016
SP A, SP
Flow sleeves
Applications
Accessories
Zinc anodes
87
SP A, SP
Applications
SA-SPM control boxes are used as starting units for
single-phase, 3-wire motors, types MS 402B and
MS 4000.
Accessories
Fig. 26 SA-SPM
Product numbers
Product
number
Product
IN
Supply
voltage
CS
CR
[A]
[V]
[F]
[F] [F]
PSC
96802243 4.0
63-80
96786467 6.0
80-100
96786468 7.5
100-125
125-160
40
160-200
50
250-315
60
220-240
96786482 3.0
16
96786483 4.5
20
96786484 6.0
30
96786485 8.5
40
88
Capacitor size
Power
[kW]
Capacitor
Control box
16 F, 400 V, 50 Hz
0.37
ID2970
96023791
20 F, 400 V, 50 Hz
0.55
ID2971
96023792
30 F, 400 V, 50 Hz
0.75
ID2973
96023793
40 F, 400 V, 50 Hz
1.1
ID2974
96023794
SP A, SP
Accessories
Ambient temperature
-20 C to +60 C
95 % (condensating)
Voltage variation
Approvals
UL, DNV
Marking
CE
Product number
Cable length
[m]
GrA3187 3607
GrA3186 0407
GrA3190 0407
MS6
MS 6000
MMS6
MMS 6000
MMS 8000
MMS 10000
MMS 12000
20
96408953
96494596
96437287
40
96408681
96494597
96437288
96437289
60
PR 5714 relay
Material
96408954
96494598
80
N-version
96408955
96494599
96437290
100
96408956
96494610
96437291
20
96658626
96494596
40
96658627
96494597
60
96658628
96494598
80
R-version
96658637
96494599
100
96658638
96494610
Voltage
Product number
96913234
Cable length
[m]
Product number
20
96913237
40
96913253
60
96913256
80
96913260
100
96913263
89
SP A, SP
Description
GrA3191 0407
Accessories
97550639
96803373
Description
Description
TM00 7882 2296
Sensor cable
90
Description
TM04 3560 4508
Product number
Product number
96913215
Product number
96571480
Product number
RM5271
SP A, SP
Cable
length
[m]
Enclosure class
Ambient temperature
0 C to +55 C
20 to 80 % (condensating)
Voltage variation
1 x 230 V - 15 %/+ 10 %, 50 Hz
Approvals
UR
Marking
CE
Product number
Material
MS 402
MS 4000
MMS6
MMS 6000
MMS 8000
MMS 10000
MMS 12000
98090296
96803207
96803233
96803238
40
98090311
96803241
96803252
96803253
96803257
60
98090313
96803254
96803255
80
98090318
96803258
96803292
96803294
100
98090319
96803301
96803312
96803313
N-version
20
98090363
98085486
96803233
40
98090364
98085489
96803252
60
98090365
98085579
96803255
80
98090366
98085601
96803292
100
98090367
98085602
96803312
R-version
Voltage
Product number
1 x 230 V - 15 %/+ 10 %, 50 Hz
96797484
Cable length
[m]
Product number
20
96804042
40
96804044
60
96804064
80
96804065
100
96804067
Description
TM05 3694 1612
MS6
MS 6000
20
Accessories
Product number
98090278
98090341
91
SP A, SP
Description
GrA3191 0407
Accessories
97550639
96803373
Description
Description
TM00 7882 2296
Sensor cable
92
Description
TM04 3560 4508
Product number
Product number
96913215
Product number
96571480
Product number
RM5271
SP A, SP
Energy consumption of
submersible pumps
The percentage distribution of service life costs of a
submersible pump for water supply is as follows:
5 % initial costs (pump)
85 % operating costs / energy consumption
10 % maintenance costs.
It is obvious that the highest savings can be achieved
within energy consumption!
The annual energy consumption, E, of a submersible
pump can be calculated as follows:
E = c x h x P1 (EUR)
c = specific energy price (EUR/kWh)
h = operating hours/year (hours)
P1 = power input of the submersible pump (kW).
Example: Calculation of the annual energy
consumption of the submersible pump, type SP 125-3.
SP 125-3 with MS 6000, 30 kW, 3 x 400 V, 50 Hz.
Duty point
Flow rate:
Q = 120 m3/h
Total head:
H = 63 m
Specific energy price: c = EUR 0.1/kWh
(consisting of day and night
rate)
Operating hours/year: h = 3200.
P1 =
QxHx
367 x pump x motor
in kW
3/h
Q
= m
H
= m
Density = kg/dm3 (assumed 1)
367
= conversion factor
= (not to be confused with the stage
pump
efficiency curve)
= (example 84.5 %, in equation 0.845).
motor
By showing the P2/Q curve we make it easier for you
to calculate the energy consumption.
P1 =
P2
motor
Energy consumption
7. Energy consumption
Calculation of motor efficiency at duty point
As standard, the SP 125-3 is fitted with a 30 kW
MS 6000 motor.
At duty point (Q = 120 m3/h), the pump requires 26 kW,
thus:
a motor load of 87 % (26 kW / 30 kW) and a power
reserve of 13 %.
From the table on page 71, the motor efficiency can be
read as:
85 % at a load of 75 % (75 %)
84 % at a load of 100 % (100 %)
The interpolated value in this example is
motor = 84.5 %, motor = 0.845.
P1 =
26
0.845
= 30.77 kW
x 12
4090
(EUR 12,777 EUR 9,846)
x 12 = 16.7 months
93
SP A, SP
Cable sizing
8. Cable sizing
Cables
Formula designations
U
= Rated voltage [V]
U = Voltage drop [%]
I
= Rated current of the motor [A]
cos = Power factor
Example
U x U
I x 2 x 100 x (cos x
[m]
+ sin x X L)
U x U
I x 1.73 x 100 x (cos x
94
[m]
+ sin x X L)
Motor size:
Starting method:
Rated voltage (U):
Voltage drop (U):
Rated current (I):
Power factor (cos ):
Specific resistance ():
Cross-section (q):
sin :
Inductive resistance (XL):
400 x 3
L =
L = 120 m.
0.025
25
SP A, SP
Cable sizing
Voltage drop: 3 %
kW
2.5
4"
0.37
1.4
0.64
462
767
4"
0.55
2.2
0.64
294
488
4"
0.75
2.3
0.72
250
416
662
987
4"
1.1
3.4
0.72
169
281
448
668
10
16
25
35
50
70
95
120
150
185
240
300
777
4"
1.5
4.2
0.75
132
219
348
520
857
4"
2.2
5.5
0.82
92
153
244
364
602
951
4"
7.85
0.77
69
114
182
271
447
705
4"
9.6
0.8
54
90
143
214
353
557
853
4"
5.5
13
0.81
39
66
104
156
258
407
624
855
4"
7.5
18.8
0.78
28
47
75
112
185
291
445
609
6"
9.2
0.82
55
91
146
218
359
566
867
6"
5.5
13.6
0.77
40
66
105
157
258
407
622
6"
7.5
17.6
0.8
29
49
78
117
193
304
465
637
882
6"
9.2
21.8
0.81
23
39
62
93
154
243
372
510
706
950
6"
11
24.8
0.83
34
53
80
132
209
320
440
610
823
6"
13
30
0.81
28
45
68
112
176
270
370
513
690
6"
15
34
0.82
39
59
97
154
236
324
449
604
783
947
6"
18.5
42
0.81
48
80
126
193
265
366
493
638
770
6"
22
48
0.84
41
67
107
164
225
313
422
549
665
793
927
6"
26
57
0.84
57
90
138
189
263
355
462
560
667
781
937
6"
30
66.5
0.83
49
78
119
164
227
307
398
482
574
670
803
926
6"
37
85.5
0.79
63
97
133
183
246
317
382
452
525
624
714
8"
22
48
0.84
67
107
164
225
313
422
549
665
793
927
8"
26
56.5
0.85
57
90
138
189
263
356
464
563
672
787
8"
30
64
0.85
50
79
122
167
233
314
409
497
593
695
836
968
8"
37
78.5
0.85
65
99
136
190
256
334
405
483
567
682
789
8"
45
96.5
0.82
54
83
114
158
213
276
334
396
462
553
636
8"
55
114
0.85
68
94
131
177
230
279
333
390
469
544
8"
63
132
0.83
83
115
155
201
243
289
338
404
466
8"
75
152
0.86
70
97
132
171
208
249
292
353
409
8"
92
186
0.86
79
107
140
170
204
239
288
335
8"
110
224
0.87
89
116
141
169
198
240
279
10"
75
156
0.84
96
130
169
205
244
285
343
396
10"
92
194
0.82
79
106
137
166
197
230
275
316
10"
110
228
0.84
89
116
140
167
195
234
271
10"
132
270
0.84
98
118
141
165
198
229
10"
147
315
0.81
103
122
142
169
194
10"
170
365
0.81
105
122
146
168
10"
190
425
0.79
106
125
144
12"
147
305
0.83
105
125
146
175
202
12"
170
345
0.85
92
110
129
155
180
12"
190
390
0.84
98
114
137
158
12"
220
445
0.85
100
120
139
12"
250
505
0.85
Dimensions
[mm2]
Motor
41
850
69
23
30
41
53
74
99
131
841
162
202
250
893
301
352
914
404
461
947
106
123
547
633
At particularly favourable heat dissipation conditions. Maximum cable length in metres from motor starter to pump.
For motors with star-delta starting, the cable length can be calculated by multiplying the relevant cable length from the above table by 3 .
95
SP A, SP
Cable sizing
Sizing of cable
Formula designations
U
=
U =
I
=
cos =
Star-delta
q =
p =
3 x L x x I2
q
Example
Motor size:
Voltage:
Starting method:
Rated current (In):
Required cable length (L):
Water temperature:
Cable selection
3 x L x x I2
q
3 x 200 x 0.02 x 96.52
150
I x 100 x L x x cos
The values of the rated current (I) and the power factor
(cos ) can be read in the tables on pages 71 to 76.
3 x 150 mm2.
3 x 185 mm2.
Choice A:
Choice B:
pA =
U x U (I x 100 x L x XL x sin )
p A = 745 W.
Choice B
pB =
p B = 604 W.
Savings
Operating hours/year: h = 4000.
Annual saving (A):
A = (pA - pB) x h = (745 W - 604 W) x 4000 =
564,000 Wh = 564 kWh.
By choosing the cable size 3 x 185 mm2 instead of
3 x 150 mm2, an annual saving of 564 kWh is
achieved.
Operating time: 10 years.
Saving after 10 years (A10):
A10 = A x 10 = 564 x 10 = 5640 kWh.
The saved amount must be calculated in the local
currency.
96
SP A, SP
m3/h
Litres/min.
Litres/sec.
0.6
10
0.16
0.9
15
0.25
1.2
20
0.33
1.5
25
0.42
1.8
30
0.50
2.1
35
0.58
2.4
40
0.67
3.0
50
0.83
3.6
60
1.00
4.2
70
1.12
4.8
80
1.33
5.4
90
1.50
6.0
100
1.67
7.5
125
2.08
9.0
150
2.50
10.5
175
2.92
12
200
3.33
15
250
4.17
18
300
5.00
24
400
6.67
30
500
8.33
36
600
10.0
42
700
11.7
48
800
13.3
54
900
15.0
60
1000
16.7
75
1250
20.8
90
1500
25.0
105
1750
29.2
120
2000
33.3
150
2500
41.7
180
3000
50.0
240
4000
66.7
5000
83.3
300
1/2"
15.75
0.855
9.910
1.282
20.11
1.710
33.53
2.138
49.93
2.565
69.34
2.993
91.54
3/4"
21.25
0.470
2.407
0.705
4.862
0.940
8.035
1.174
11.91
1.409
16.50
1.644
21.75
1.879
27.66
2.349
41.40
2.819
57.74
3.288
76.49
1"
27.00
0.292
0.784
0.438
1.570
0.584
2.588
0.730
3.834
0.876
5.277
1.022
6.949
1.168
8.820
1.460
13.14
1.751
18.28
2.043
24.18
2.335
30.87
2.627
38.30
2.919
46.49
3.649
70.41
1 1/4"
35.75
1 1/2"
41.25
2"
52.50
2 1/2"
68.00
3"
80.25
3 1/2"
92.50
4"
105.0
0.249
0.416
0.331
0.677
0.415
1.004
0.498
1.379
0.581
1.811
0.664
2.290
0.830
3.403
0.996
4.718
1.162
6.231
1.328
7.940
1.494
9.828
1.660
11.90
2.075
17.93
0.249
0.346
0.312
0.510
0.374
0.700
0.436
0.914
0.499
1.160
0.623
1.719
0.748
2.375
0.873
3.132
0.997
3.988
1.122
4.927
1.247
5.972
1.558
8.967
0.231
0.223
0.269
0.291
0.308
0.368
0.385
0.544
0.462
0.751
0.539
0.988
0.616
1.254
0.693
1.551
0.770
1.875
0.962
2.802
0.229
0.159
0.275
0.218
0.321
0.287
0.367
0.363
0.413
0.449
0.459
0.542
0.574
0.809
0.231
0.131
0.263
6.164
0.269
0.203
0.329
0.244
0.412
0.365
0.248
0.124
0.310
0.185
0.241
0.101
0.494
0.506
0.576
0.670
0.659
0.855
0.823
1.282
0.988
1.792
1.317
3.053
1.647
4.622
1.976
6.505
2.306
8.693
2.635
11.18
2.964
13.97
3.294
17.06
4.117
26.10
0.372
0.256
0.434
0.338
0.496
0.431
0.620
0.646
0.744
0.903
0.992
1.530
1.240
2.315
1.488
3.261
1.736
4.356
1.984
5.582
2.232
6.983
2.480
8.521
3.100
13.00
4.941
36.97
3.720
18.42
4.340
24.76
2.490
25.11
2.904
33.32
3.319
42.75
4.149
64.86
1.0
4.0
1.0
4.0
1.1
4.0
1.2
5.0
1.870
12.53
2.182
16.66
2.493
21.36
3.117
32.32
3.740
45.52
4.987
78.17
1.3
5.0
1.154
3.903
1.347
5.179
1.539
6.624
1.924
10.03
2.309
14.04
3.078
24.04
3.848
36.71
4.618
51.84
1.4
5.0
0.668
1.124
0.803
1.488
0.918
1.901
1.147
2.860
1.377
4.009
1.836
6.828
2.295
10.40
2.753
14.62
3.212
19.52
3.671
25.20
4.130
31.51
4.589
38.43
1.5
6.0
1.6
6.0
5"
130.0
6"
155.5
0.289
0.140
0.337
0.184
0.385
0.234
0.481
0.350
0.577
0.488
0.770
0.829
0.962
1.254
1.155
1.757
1.347
2.345
1.540
3.009
1.732
3.762
1.925
4.595
2.406
7.010
0.251
0.084
0.314
0.126
0.377
0.175
0.502
0.294
0.628
0.445
0.753
0.623
0.879
0.831
1.005
1.066
1.130
1.328
1.256
1.616
1.570
2.458
0.263
0.074
0.351
0.124
0.439
0.187
0.526
0.260
0.614
0.347
0.702
0.445
0.790
0.555
0.877
0.674
1.097
1.027
2.887
9.892
1.883
3.468
1.316
1.444
4.960
31.94
3.368
13.30
3.850
17.16
4.812
26.26
2.197
4.665
2.511
5.995
3.139
9.216
3.767
13.05
5.023
22.72
1.6
6.0
1.7
7.0
2.0
8.0
1.535
1.934
1.754
2.496
2.193
3.807
2.632
5.417
3.509
8.926
4.386
14.42
2.5
9.0
The table is calculated in accordance with H. Lang's new formula a = 0.02 and for a water temperature of 10 C.
The head loss in bends, slide valves, T-pieces and non-return valves is equivalent to the metres of straight pipes stated in the last two lines of the table.
To find the head loss in foot valves, multiply the loss in T-pieces by two.
97
SP A, SP
PELM/PEH PN 10
PELM
m3/h
Litres/min.
Litres/sec.
0.6
10
0.16
0.9
15
0.25
1.2
20
0.33
1.5
25
0.42
1.8
30
0.50
2.1
35
0.58
2.4
40
0.67
3.0
50
0.83
3.6
60
1.00
4.2
70
1.12
4.8
80
1.33
5.4
90
1.50
6.0
100
1.67
7.5
125
2.08
9.0
150
2.50
10.5
175
2.92
12
200
3.33
15
250
4.17
18
300
5.00
24
400
6.67
30
500
8.33
36
600
10.0
42
700
11.7
48
800
13.3
54
900
15.0
60
1000
16.7
75
1250
20.8
90
1500
25.0
105
1750
29.2
120
2000
33.3
150
2500
41.7
180
3000
50.0
240
4000
66.7
300
5000
83.3
98
25
20.4
0.49
1.8
0.76
4.0
1.0
6.4
1.3
10.0
1.53
13.0
1.77
16.0
2.05
22.0
2.54
37.0
3.06
43.0
3.43
50.0
PEH
32
26.2
0.30
0.66
0.46
1.14
0.61
2.2
0.78
3.5
0.93
4.6
1.08
6.0
1.24
7.5
1.54
11.0
1.85
15.0
2.08
18.0
2.47
25.0
2.78
30.0
3.1
39.0
40
32.6
0.19
0.27
0.3
0.6
0.39
0.9
0.5
1.4
0.6
1.9
0.69
2.0
0.80
3.3
0.99
4.8
1.2
6.5
1.34
8.0
1.59
10.5
1.8
12.0
2.0
16.0
50
40.8
0.12
0.085
0.19
0.18
0.25
0.28
0.32
0.43
0.38
0.57
0.44
0.70
0.51
0.93
0.63
1.40
0.76
1.90
0.86
2.50
1.02
3.00
1.15
3.50
1.28
4.6
3.86
50.0
2.49
24.0
3.00
33.0
3.5
38.0
3.99
50.0
1.59
6.6
1.91
8.6
2.23
11.0
2.55
14.0
3.19
21.0
3.82
28.0
63
51.4
0.12
0.63
0.16
0.11
0.2
0.17
0.24
0.22
0.28
0.27
0.32
0.35
0.4
0.50
0.48
0.70
0.54
0.83
0.64
1.20
0.72
1.30
0.8
1.80
1.00
2.50
1.20
3.5
1.41
4.3
1.60
5.5
2.01
8.0
2.41
10.5
3.21
19.0
4.01
28.0
4.82
37.0
5.64
47.0
75
61.4
0.14
0.074
0.17
0.092
0.2
0.12
0.23
0.16
0.28
0.22
0.34
0.32
0.38
0.38
0.45
0.50
0.51
0.57
0.56
0.73
0.70
1.10
0.84
1.40
0.99
1.80
1.12
2.40
1.41
3.70
1.69
4.60
2.25
8.0
2.81
11.5
3.38
15.0
3.95
24.0
4.49
26.0
5.07
33.0
5.64
40.0
90
73.6
110
90.0
125
102.2
0.16
0.063
0.2
0.09
0.24
0.13
0.26
0.17
0.31
0.22
0.35
0.26
0.16
0.050
0.18
0.068
0.2
0.084
0.24
0.092
0.18
0.05
0.39
0.30
0.49
0.50
0.59
0.63
0.69
0.78
0.78
1.0
0.98
1.50
1.18
1.95
1.57
3.60
1.96
5.0
0.26
0.12
0.33
0.18
0.39
0.24
0.46
0.30
0.52
0.40
0.66
0.57
0.78
0.77
1.05
1.40
1.31
2.0
0.2
0.07
0.25
0.10
0.30
0.13
0.36
0.18
0.41
0.22
0.51
0.34
0.61
0.45
0.81
0.78
1.02
1.20
2.35
6.6
2.75
8.0
3.13
11.0
3.53
13.5
3.93
16.0
4.89
25.0
5.88
33.0
6.86
44.0
1.57
2.60
1.84
3.50
2.09
4.5
2.36
5.5
2.63
6.7
3.27
9.0
3.93
13.0
4.59
17.5
5.23
23.0
6.55
34.0
7.86
45.0
1.22
1.50
1.43
1.90
1.62
2.60
1.83
3.20
2.04
3.90
2.54
5.0
3.05
8.0
3.56
9.7
4.06
13.0
5.08
18.0
6.1
27.0
8.13
43.0
140
114.6
160
130.8
180
147.2
0.20
0.055
0.24
0.075
0.28
0.09
0.32
0.12
0.40
0.18
0.48
0.25
0.65
0.44
0.81
0.63
0.25
0.065
0.31
0.105
0.37
0.13
0.50
0.23
0.62
0.33
0.25
0.06
0.29
0.085
0.39
0.15
0.49
0.21
0.97
0.82
1.13
1.10
1.29
1.40
1.45
1.70
1.62
2.2
2.02
3.0
2.42
4.1
2.83
5.7
3.23
7.0
4.04
10.5
4.85
14.0
0.74
0.45
0.87
0.60
0.99
0.81
1.12
0.95
1.24
1.2
1.55
1.6
1.86
2.3
2.17
3.2
2.48
4.0
3.10
6.0
3.72
7.6
0.59
0.28
0.69
0.40
0.78
0.48
0.08
0.58
0.96
0.75
1.22
0.95
1.47
1.40
1.72
1.9
1.96
2.4
2.45
3.5
2.94
4.4
6.47
24.0
8.08
33.0
4.96
13.0
6.2
18.0
3.92
7.5
4.89
11.0
10
SP A, SP
WebCAPS
Catalogue
Based on fields of application and pump types, this section
contains the following:
technical data
curves (QH, Eta, P1, P2, etc.) which can be adapted to the
density and viscosity of the pumped liquid and show the
number of pumps in operation
product photos
dimensional drawings
wiring diagrams
quotation texts, etc.
Literature
This section contains all the latest documents of a given pump,
such as
data booklets
installation and operating instructions
service documentation, such as Service kit catalogue and
Service kit instructions
quick guides
product brochures.
Service
This section contains an easy-to-use interactive service
catalogue. Here you can find and identify service parts of both
existing and discontinued Grundfos pumps.
Furthermore, the section contains service videos showing you
how to replace service parts.
99
10
SP A, SP
Sizing
Replacement
In this section you find a guide to selecting and comparing
replacement data of an installed pump in order to replace the
pump with a more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.
Based on an easy step-by-step guide, you can compare
Grundfos pumps with the one you have installed on your site.
When you have specified the installed pump, the guide will
suggest a number of Grundfos pumps which can improve both
comfort and efficiency.
CAD drawings
In this section, it is possible to download 2-dimensional (2D) and
3-dimensional (3D) CAD drawings of most Grundfos pumps.
These formats are available in WebCAPS:
2-dimensional drawings:
.dxf, wireframe drawings
.dwg, wireframe drawings.
3-dimensional drawings:
.dwg, wireframe drawings (without surfaces)
.stp, solid drawings (with surfaces)
.eprt, E-drawings.
WinCAPS
Subject to alterations.
100
101
102
103
V7023747 1012
ECM: 1100777
The name Grundfos, the Grundfos logo, and the payoff be think innovate are registered trademarks
owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.