You are on page 1of 326

Electric Drives

and Controls

Hydraulics

Linear Motion and


Assembly Technologies

Rexroth IndraDrive
Supply Units and
Power Sections
Project Planning Manual

Pneumatics

Service

R911318790
Edition 01

Bosch Rexroth AG | Electric Drives


and Controls

Title

Rexroth IndraDrive | Project Planning Manual

Rexroth IndraDrive
Supply Units and
Power Sections

Type of Documentation
Document Typecode
Internal File Reference
Record of Revision

Copyright

Validity

Published by

Project Planning Manual


DOK-INDRV*-HMV-S-D+HCS-PR01-EN-P
RS-dfb5157c0a6846ac0005d70aedbf4f52-3-en-US-4
Edition

Release Date

Notes

120-2400-B331-01/EN

2007/03

First edition

2007 Bosch Rexroth AG


Copying this document, giving it to others and the use or communication of the
contents thereof without express authourity, are forbidden. Offenders are liable
for the payment of damages. All rights are reserved in the event of the grant of
a patent or the registration of a utility model or design (DIN 34-1).
The specified data is for product description purposes only and may not be
deemed to be guaranteed unless expressly confirmed in the contract. All rights
are reserved with respect to the content of this documentation and the availa
bility of the product.
Bosch Rexroth AG
Bgm.-Dr.-Nebel-Str. 2 D-97816 Lohr a. Main
Telephone +49 (0)93 52/ 40-0 Fax +49 (0)93 52/ 40-48 85
http://www.boschrexroth.com/
Dept. BRC/EDY1 (RR/US/BB)

Note

This document has been printed on chlorine-free bleached paper.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

I/VI

Table of Contents

Table of Contents
Page

1
1.1
1.2
1.2.1
1.3

2
2.1
2.1.1
2.1.2
2.2

3
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8

4
4.1
4.2
4.2.1
4.2.2
4.3
4.3.1
4.3.2

4.3.3
4.4

5
5.1

Introduction.................................................................................................................... 1
About this Documentation....................................................................................................................... 1
Reference Documentations ................................................................................................................... 1
Overview.............................................................................................................................................. 1
Your Feedback....................................................................................................................................... 3

Important Directions for Use ......................................................................................... 5


Appropriate Use ..................................................................................................................................... 5
Introduction.......................................................................................................................................... 5
Areas of Use and Application.............................................................................................................. 5
Inappropriate Use .................................................................................................................................. 6

Safety Instructions for Electric Drives and Controls ...................................................... 7


Safety Instructions - General Information............................................................................................... 7
Using the Safety Instructions and Passing them on to Others............................................................ 7
How to Employ the Safety Instructions................................................................................................ 7
Explanation of Warning Symbols and Degrees of Hazard Seriousness.............................................. 8
Hazards by Improper Use.................................................................................................................... 9
Instructions with Regard to Specific Dangers....................................................................................... 10
Protection Against Contact with Electrical Parts and Housings......................................................... 10
Protection Against Electric Shock by Protective Extra-Low Voltage................................................. 11
Protection Against Dangerous Movements....................................................................................... 11
Protection Against Magnetic and Electromagnetic Fields During Operation and Mounting.............. 14
Protection Against Contact with Hot Parts......................................................................................... 14
Protection During Handling and Mounting......................................................................................... 14
Battery Safety.................................................................................................................................... 15
Protection Against Pressurized Systems........................................................................................... 15

General Specifications of the Components ................................................................. 17


Certifications ........................................................................................................................................ 17
Transport and Storage.......................................................................................................................... 19
Transporting the Devices .................................................................................................................. 19
Storing the Devices .......................................................................................................................... 19
Installation Conditions .......................................................................................................................... 20
Ambient and Operating Conditions ................................................................................................... 20
Positions of Normal Use and Mounting Positions ............................................................................. 21
General Information........................................................................................................................ 21
Brief Description of Positions of Normal Use and Mounting Positions........................................... 21
Compatibility with Foreign Matters ................................................................................................... 22
Capacity Utilization .............................................................................................................................. 22

Power Sections for Converters - IndraDrive C............................................................. 25


Types ................................................................................................................................................... 25

II/VI

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Table of Contents
Page
5.2
5.2.1
5.2.2

5.2.3
5.2.4

5.2.5

5.3
5.3.1
5.3.2

5.3.3
5.3.4

5.3.5

6
6.1
6.2
6.2.1
6.2.2

6.2.3
6.2.4

6.2.5
6.3
6.3.1

HCS02 Power Sections ....................................................................................................................... 25


Brief Description, Usage and Structure............................................................................................. 25
Type Code and Identification............................................................................................................. 29
Type Code ..................................................................................................................................... 29
Identification................................................................................................................................... 31
Scope of Supply ............................................................................................................................... 32
Technical Data................................................................................................................................... 32
Ambient and Operating Conditions................................................................................................. 32
Mechanical System and Mounting.................................................................................................. 34
Basic Data Power Section HCS02................................................................................................. 40
Exemplary Data for Applications.................................................................................................... 49
Connections and Interfaces............................................................................................................... 57
Overview......................................................................................................................................... 57
Description of the Connection Points............................................................................................. 62
HCS03 Power Sections ....................................................................................................................... 62
Brief Description, Usage and Structure............................................................................................. 62
Type Code and Identification............................................................................................................. 64
Type Code...................................................................................................................................... 64
Identification................................................................................................................................... 66
Scope of Supply ............................................................................................................................... 66
Technical Data................................................................................................................................... 67
Ambient and Operating Conditions................................................................................................. 67
Mechanical System and Mounting.................................................................................................. 68
Basic Data Power Section HCS03................................................................................................. 80
Exemplary Data for Applications.................................................................................................... 88
Connections and Interfaces............................................................................................................... 95
Overview......................................................................................................................................... 95
Description of the Connection Points............................................................................................. 98

Power Sections for Inverters - IndraDrive M................................................................ 99


Types ................................................................................................................................................... 99
HMS01 Power Sections ....................................................................................................................... 99
Brief Description, Usage and Structure............................................................................................. 99
Type Code and Identification........................................................................................................... 101
Type Code.................................................................................................................................... 101
Identification................................................................................................................................. 103
Scope of Supply ............................................................................................................................. 104
Technical Data................................................................................................................................. 104
Ambient and Operating Conditions............................................................................................... 104
Mechanical System and Mounting................................................................................................ 107
Basic Data Power Section HMS01............................................................................................... 117
Exemplary Data for Applications.................................................................................................. 124
Connections and Interfaces............................................................................................................. 134
Overview....................................................................................................................................... 134
HMS02 Power Sections ..................................................................................................................... 140
Brief Description, Usage and Structure........................................................................................... 140

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

III/VI

Table of Contents
Page
6.3.2

6.3.3
6.3.4

6.3.5

6.4
6.4.1
6.4.2

6.4.3
6.4.4

6.4.5

7
7.1
7.2
7.2.1
7.2.2

7.2.3
7.2.4

7.2.5

7.3
7.3.1
7.3.2

Type Code and Identification........................................................................................................... 142


Type Code.................................................................................................................................... 142
Identification................................................................................................................................. 143
Scope of Supply ............................................................................................................................. 143
Technical Data................................................................................................................................. 144
Ambient and Operating Conditions............................................................................................... 144
Mechanical System and Mounting................................................................................................ 146
Basic Data Power Section HMS02............................................................................................... 150
Exemplary Data for Applications.................................................................................................. 154
Connections and Interfaces............................................................................................................. 159
Overview....................................................................................................................................... 159
Description of the Connection Points........................................................................................... 162
HMD01 Power Sections ..................................................................................................................... 162
Brief Description, Usage and Structure........................................................................................... 162
Type Code and Identification........................................................................................................... 163
Type Code.................................................................................................................................... 163
Identification................................................................................................................................. 165
Scope of Supply ............................................................................................................................. 166
Technical Data................................................................................................................................. 166
Ambient and Operating Conditions............................................................................................... 166
Mechanical System and Mounting................................................................................................ 168
Basic Data Power Section HMD01............................................................................................... 173
Exemplary Data for Applications.................................................................................................. 177
Connections and Interfaces............................................................................................................. 183
Overview....................................................................................................................................... 183
Description of the Connection Points........................................................................................... 185

IndraDrive M Supply Units......................................................................................... 187


Types ................................................................................................................................................. 187
HMV01.1E Supply Units, Infeeding ................................................................................................... 187
Brief Description, Usage and Structure........................................................................................... 187
Type Code and Identification........................................................................................................... 188
Type Code.................................................................................................................................... 188
Identification................................................................................................................................. 190
Scope of Supply ............................................................................................................................. 190
Technical Data HMV01.1E.............................................................................................................. 191
Ambient and Operating Conditions............................................................................................... 191
Mechanical System and Mounting................................................................................................ 193
Basic Data Supply Unit HMV01, Infeeding................................................................................... 196
Exemplary Data for Applications.................................................................................................. 202
Connections and Interfaces............................................................................................................. 206
Overview....................................................................................................................................... 206
Description of the Connection Points........................................................................................... 209
HMV01.1R Supply Units, Regenerative ............................................................................................. 209
Brief Description, Usage and Structure........................................................................................... 209
Type Code and Identification........................................................................................................... 210

IV/VI

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Table of Contents
Page

7.3.3
7.3.4

7.3.5

7.4
7.4.1
7.4.2

7.4.3
7.4.4

7.4.5

8
8.1
8.2
8.3
8.4
8.4.1
8.4.2
8.5
8.5.1
8.5.2
8.5.3
8.5.4
8.5.5
8.5.6
8.5.7
8.5.8
8.6
8.6.1

Type Code.................................................................................................................................... 210


Identification................................................................................................................................. 211
Scope of Supply ............................................................................................................................. 211
Technical Data HMV01.1R.............................................................................................................. 212
Ambient and Operating Conditions............................................................................................... 212
Mechanical System and Mounting................................................................................................ 214
Basic Data Supply Unit HMV01, Regenerative............................................................................ 217
Exemplary Data for Applications.................................................................................................. 223
Connections and Interfaces............................................................................................................. 227
Overview....................................................................................................................................... 227
Description of the Connection Points........................................................................................... 230
HMV02.1R Supply Units, Regenerative ............................................................................................. 230
Brief Description, Usage and Structure........................................................................................... 230
Type Code and Identification........................................................................................................... 231
Type Code.................................................................................................................................... 231
Identification................................................................................................................................. 233
Scope of Supply ............................................................................................................................. 233
Technical Data HMV02.1R.............................................................................................................. 234
Ambient and Operating Conditions............................................................................................... 234
Mechanical System and Mounting................................................................................................ 236
Basic Data Supply Unit HMV02, Regenerative............................................................................ 239
Exemplary Data for Applications.................................................................................................. 244
Connections and Interfaces............................................................................................................. 249
Overview....................................................................................................................................... 249
Arrangement of the Connection Points......................................................................................... 252
Description of the Connection Points........................................................................................... 253

Functions and Electrical Connection Points .............................................................. 255


Overview of Functions........................................................................................................................ 255
Electrical Connection Points Overview............................................................................................ 257
X1, Module Bus ................................................................................................................................. 258
X2, Serial Interface (RS232) .............................................................................................................. 259
General Information......................................................................................................................... 259
Connection Diagrams Serial Interface to PC .................................................................................. 260
X3, Mains Connection ........................................................................................................................ 260
Important Notes............................................................................................................................... 260
X3, Mains Connection HMV02.1R-W0015...................................................................................... 261
X3, Mains Connection HCS02.1E-W0012, -W0028........................................................................ 262
X3, Mains Connection HCS02.1E-W0054, -W0070 and HCS03.1E-W0070................................... 262
X3, Mains Connection HCS03.1E-W0100..0150 and HMV01.1R-W0018..0065; HMV01.1EW0030..0075................................................................................................................................... 263
X3, Mains Connection HCS03.1E-W0210....................................................................................... 264
X3, Mains Connection HMV01.1E-W0120 and HMV01.1R-W0120................................................ 264
X3, Mains Connection HCS04.1E-W0500 (Preliminary)................................................................. 265
X5, Motor Connection ........................................................................................................................ 266
Important Notes............................................................................................................................... 266

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

V/VI

Table of Contents
Page
8.6.2
8.6.3
8.6.4
8.6.5
8.6.6
8.6.7
8.6.8
8.7
8.7.1
8.7.2
8.8
8.8.1
8.8.2
8.8.3
8.9
8.10
8.10.1
8.11
8.11.1
8.11.2
8.11.3
8.12
8.13
8.14
8.15
8.16
8.17
8.18
8.19
8.20
8.21
8.22

X5, Motor Connection HCS02.1E-W0012, -W0028 and HMS01.1N-W0020, -W0036 and HMD01.1NW0012..0036 and HMS02.1N-W0028............................................................................................. 267
X5, Motor Connection HCS02.1E-W0054, -W0070 and HCS03.1E-W0070 and HMS01.1N-W0054, W0070 and HMS02.1N-W0054....................................................................................................... 268
X5, Motor Connection HMS01.1N-W0110....................................................................................... 268
X5, Motor Connection HCS03.1E-W0100..0150 and HMS01.1N-W0150..0210............................. 269
X5, Motor Connection HCS03.1E-W0210....................................................................................... 270
X5, Motor Connection HMS01.1N-W0350 (Preliminary)................................................................. 270
X5, Motor Connection HCS04.1E-W0500 (Preliminary).................................................................. 271
X6, Motor Temperature Monitoring and Motor Holding Brake ........................................................... 272
Important Notes............................................................................................................................... 272
Connection Point............................................................................................................................. 273
X9, External Braking Resistor ............................................................................................................ 275
Important Notes............................................................................................................................... 275
X9, External Braking Resistor HCS02.1E-W0054, -W0070............................................................ 275
X9, Externals Braking Resistor HCS03.1E-W0070...0210.............................................................. 276
X13, Control Voltage (24V, 0V) ......................................................................................................... 277
X13, Supply External Blower Unit HAB01 ......................................................................................... 278
General Information......................................................................................................................... 278
X14, Mains Voltage Synchronization ................................................................................................. 280
Connection Point............................................................................................................................. 280
Mains Synchronization HMV01 ...................................................................................................... 280
Mains Synchronization HMV02 ...................................................................................................... 281
X31, Messages Bb1, UD, WARN ...................................................................................................... 282
X32, Mains Contactor Control and DC Bus Short Circuit .................................................................. 284
X33, Acknowledge Messages of Mains Contactor ............................................................................ 286
X34, Contact for Controlling the External Mains Contactor ............................................................... 288
Terminal Block, 24 - 0V (24V Supply) ................................................................................................ 290
DC Bus Connection (L+, L-) .............................................................................................................. 291
XS1, Shield Connection Control Lines ............................................................................................... 293
XS2, Shield Connection Motor Cable ................................................................................................ 293
Ground Connection ............................................................................................................................ 294
Connection Point of Equipment Grounding Conductor, HMV ............................................................ 294
Equipment Grounding Conductor Connection HMS, HMD ................................................................ 296

Touch Guard at Devices ........................................................................................... 299

9.1
9.2

Cutouts............................................................................................................................................... 299
Mounting............................................................................................................................................. 300

10

Operation and Diagnosis........................................................................................... 301

10.1
10.1.1

10.1.2

Operation and Diagnosis at IndraDrive Supply Units......................................................................... 301


Control Panel................................................................................................................................... 301
Brief Description........................................................................................................................... 301
Functional Description.................................................................................................................. 301
Diagnostic Messages Displayed at IndraDrive M Supply Units....................................................... 305
HMV - Diagnostic Messages for Operating States and During the Initialization Phase............... 305

VI/VI

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Table of Contents
Page

10.2
10.2.1
10.2.2

11
11.1
11.1.1
11.1.2
11.2
11.2.1
11.2.2

11.2.3

12
12.1
12.2
12.3
12.4

HMV - Diagnostic Warning Messages.......................................................................................... 305


HMV - Diagnostic Error Messages............................................................................................... 306
HMV - Diagnostic Command Messages....................................................................................... 307
Operation and Diagnosis at IndraDrive Controllers............................................................................ 308
Control Panel................................................................................................................................... 308
Diagnostic Messages Displayed at Drive Controllers...................................................................... 308

Disposal and Environmental Protection..................................................................... 309


Disposal.............................................................................................................................................. 309
Products.......................................................................................................................................... 309
Packaging Materials........................................................................................................................ 309
Environmental Protection.................................................................................................................... 309
No Release of Hazardous Substances............................................................................................ 309
Materials Contained in the Products................................................................................................ 309
Electronic Devices........................................................................................................................ 309
Motors........................................................................................................................................... 309
Recycling......................................................................................................................................... 310

Service & Support...................................................................................................... 311


Helpdesk............................................................................................................................................. 311
Service Hotline.................................................................................................................................... 311
Internet................................................................................................................................................ 311
Helpful Information.............................................................................................................................. 311

Index.......................................................................................................................... 313

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

1/315

Introduction

Introduction

1.1

About this Documentation


Personal injury and property damage caused by incorrect project plan
ning for applications, machines and installations!
Observe the contents of the reference documentations relevant to your drive
system (see chapter 1.2 Reference Documentations , page 1).

WARNING

In particular, take the Project Planning Manual Rexroth IndraDrive, Drive Sys
tem into account.
Purpose of Documentation

This documentation provides information on

how to configure Rexroth IndraDrive systems

considering the components

Changes in Comparison to Previ


ous Edition

HMV supply units

HMS, HMD, HCS02, HCS03 power sections


This documentation replaces the individual documentations of power sections
and supply units.
Chapter

Changes
The Project Planning Manuals of HCS02,
HCS03, HMS01, HMD01, HMS02, HMV01
and HMV02 were integrated in this Project
Planning Manual.

Functions and Electrical Connection


Points

reference to Project Planning Manual of


drive system removed for X14

Power Sections for Converters

preliminary technical data of HCS04 inclu


ded

Power Sections for Inverters

technical data of HMS01.1N-W0110 inclu


ded

Supply Units

technical data of HMV01.1R-W0120 inclu


ded

Operation and Diagnosis

lists of diagnostic messages for HMV sup


ply units included

Fig.1-1:

Changes

1.2

Reference Documentations

1.2.1

Overview
The following documentations contain detailed information on the
allowed applications, as well as the application, ambient and oper
ating conditions.
Reference Documentations - Drive Controllers

Title

Kind of documentation

Document typecode1)

Rexroth IndraDrive Drive System

Project Planning Manual

DOK-INDRV*-SYSTEM*****-PRxx-EN-P

Rexroth IndraDrive Supply Units and Pow


er Sections

Project Planning Manual

DOK-INDRV*-HMV-S-D+HCS-PR01-EN-P

2/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Introduction
Title

Kind of documentation

Document typecode1)

Rexroth IndraDrive Drive Controllers


Control Sections

Project Planning Manual

DOK-INDRV*-CSH********-PRxx-EN-P

Rexroth IndraDrive Additional Compo


nents

Project Planning Manual

DOK-INDRV*-ADDCOMP****-PRxx-EN-P

1)

Fig.1-2:

In the document typecodes, "xx" is a wild card for the current edition of
the documentation (example: "PR01" is the first edition of a Project
Planning Manual)

Documentations - overview

The following documentations describe the firmware and contain


information on its scope of functions.
Reference Documentations - Firmware for Drive Controllers
Title

Kind of documentation

Document typecode1)

Rexroth IndraDrive Firmware for Drive


Controllers

Functional Description

DOK-INDRV*-MP*-02VRS**-FKxx-EN-P

Rexroth IndraDrive Firmware for Drive


Controllers

Functional Description

DOK-INDRV*-MP*-03VRS**-FKxx-EN-P

Rexroth IndraDrive Firmware for Drive


Controllers

Functional Description

DOK-INDRV*-MP*-04VRS**-FKxx-EN-P

Rexroth IndraDrive Firmware for Drive


Controllers

Parameter Description

DOK-INDRV*-GEN-**VRS**-PAxx-EN-P

Rexroth IndraDrive Firmware for Drive


Controllers

Troubleshooting Guide

DOK-INDRV*-GEN-**VRS**-WAxx-EN-P

Rexroth IndraDrive Integrated Safety


Technology

Functional and Application


Description
1)

Fig.1-3:

DOK-INDRV*-SI*-**VRS**-FKxx-EN-P

In the document typecodes, "xx" is a wild card for the current edition of
the documentation (example: "PR01" is the first edition of a Project
Planning Manual)

Documentations - overview

Reference Documentations - Motors


Title

Kind of documentation

Rexroth Connection Cables

Selection Data

Document typecode1)
DOK-CONNEC-CABLE*STAND-AUxx-EN-P

Rexroth IndraDyn A Asynchronous Motors

Project Planning Manual

DOK-MOTOR*-MAD/MAF****-PRxx-EN-P

Rexroth IndraDyn H Frameless Synchro


nous Spindle Motors

Project Planning Manual

DOK-MOTOR*-MBS-H******-PRxx-EN-P

Rexroth IndraDyn L Synchronous Linear


Motors

Project Planning Manual

DOK-MOTOR*-MLF********-PRxx-EN-P

Rexroth IndraDyn S Synchronous Motors

Project Planning Manual

DOK-MOTOR*-MSK********-PRxx-EN-P

Rexroth IndraDyn T Synchronous Torque


Motors

Project Planning Manual

DOK-MOTOR*-MBT********-PRxx-EN-P

1)

Fig.1-4:

In the document typecodes, "xx" is a wild card for the current edition of
the documentation (example: "PR01" is the first edition of a Project
Planning Manual)

Documentations - overview

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

3/315

Introduction

1.3

Your Feedback
Your experience is important for our improvement processes of
products and documentations.
Inform us about mistakes you discovered in this documentation and changes
you suggest; we would be grateful for your feedback.
Please send your remarks to:
Address for Your Feedback

Bosch Rexroth AG
Dept. BRC/EDY1
Brgermeister-Dr.-Nebel-Str. 2
D-97816 Lohr
e-mail: brcedy1-dokusupport-drives@boschrexroth.de

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

5/315

Important Directions for Use

Important Directions for Use

2.1

Appropriate Use

2.1.1

Introduction
Rexroth products represent state-of-the-art developments and manufacturing.
They are tested prior to delivery to ensure operating safety and reliability.

Personal injury and property damage caused by incorrect use of the


products!
WARNING

The products have been designed for use in the industrial environment and may
only be used in the appropriate way. If they are not used in the appropriate way,
situations resulting in property damage and personal injury can occur.
Rexroth as manufacturer is not liable for any damages resulting
from inappropriate use. In such cases, the guarantee and the right
to payment of damages resulting from inappropriate use are forfei
ted. The user alone carries all responsibility of the risks.
Before using Rexroth products, make sure that all the pre-requisites for an ap
propriate use of the products are satisfied:

2.1.2

Personnel that in any way, shape or form uses our products must first read
and understand the relevant safety instructions and be familiar with ap
propriate use.

If the products take the form of hardware, then they must remain in their
original state, in other words, no structural changes are permitted. It is not
permitted to decompile software products or alter source codes.

Do not mount damaged or faulty products or use them in operation.

Make sure that the products have been installed in the manner described
in the relevant documentation.

Areas of Use and Application


Drive controllers made by Rexroth are designed to control electrical motors and
monitor their operation.
Control and monitoring of the Drive controllers may require additional sensors
and actors.
The drive controllers may only used with the accessories and parts
specified in this documentation. If a component has not been spe
cifically named, then it may neither be mounted nor connected. The
same applies to cables and lines.
Operation is only permitted in the specified configurations and com
binations of components using the software and firmware as speci
fied in the relevant Functional Descriptions.
Drive controllers have to be programmed before commissioning, making it pos
sible for the motor to execute the specific functions of an application.
Drive controllers of the Rexroth IndraDrive line have been developed for use in
single- and multi-axis drive and control tasks.
To ensure application-specific use of Drive controllers, device types of different
drive power and different interfaces are available.
Typical applications include:

6/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Important Directions for Use

handling and mounting systems,

packaging and food machines,

printing and paper processing machines and

machine tools.

Drive controllers may only be operated under the assembly and installation
conditions described in this documentation, in the specified position of normal
use and under the ambient conditions as described (temperature, degree of
protection, humidity, EMC, etc.).

2.2

Inappropriate Use
Using the Drive controllers outside of the operating conditions described in this
documentation and outside of the indicated technical data and specifications is
defined as "inappropriate use".
Drive controllers must not be used, if

they are subject to operating conditions that do not meet the specified
ambient conditions. This includes, for example, operation under water,
under extreme temperature fluctuations or extremely high maximum tem
peratures.

Furthermore, Drive controllers must not be used in applications which


have not been expressly authorized by Rexroth. Please carefully follow
the specifications outlined in the general Safety Instructions!

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

7/315

Safety Instructions for Electric Drives and Controls

Safety Instructions for Electric Drives and Controls

3.1

Safety Instructions - General Information

3.1.1

Using the Safety Instructions and Passing them on to Others


Do not attempt to install or commission this device without first reading all doc
umentation provided with the product. Read and understand these safety
instructions and all user documentation prior to working with the device. If you
do not have the user documentation for the device, contact your responsible
Bosch Rexroth sales representative. Ask for these documents to be sent im
mediately to the person or persons responsible for the safe operation of the
device.
If the device is resold, rented and/or passed on to others in any other form,
these safety instructions must be delivered with the device in the official lan
guage of the user's country.

WARNING

3.1.2

Improper use of these devices, failure to follow the safety instructions in


this document or tampering with the product, including disabling of safe
ty devices, may result in material damage, bodily harm, electric shock
or even death!
Observe the safety instructions!

How to Employ the Safety Instructions


Read these instructions before initial commissioning of the equipment in order
to eliminate the risk of bodily harm and/or material damage. Follow these safety
instructions at all times.

Bosch Rexroth AG is not liable for damages resulting from failure to ob


serve the warnings provided in this documentation.

Read the operating, maintenance and safety instructions in your language


before commissioning the machine. If you find that you cannot completely
understand the documentation for your product, please ask your supplier
to clarify.

Proper and correct transport, storage, assembly and installation, as well


as care in operation and maintenance, are prerequisites for optimal and
safe operation of this device.

Only assign trained and qualified persons to work with electrical installa
tions:

Only persons who are trained and qualified for the use and operation
of the device may work on this device or within its proximity. The
persons are qualified if they have sufficient knowledge of the assem
bly, installation and operation of the product, as well as an under
standing of all warnings and precautionary measures noted in these
instructions.

Furthermore, they must be trained, instructed and qualified to switch


electrical circuits and devices on and off in accordance with technical
safety regulations, to ground them and to mark them according to the
requirements of safe work practices. They must have adequate safe
ty equipment and be trained in first aid.

Only use spare parts and accessories approved by the manufacturer.

8/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Safety Instructions for Electric Drives and Controls

Follow all safety regulations and requirements for the specific application
as practiced in the country of use.

The devices have been designed for installation in industrial machinery.

The ambient conditions given in the product documentation must be ob


served.

Only use safety-relevant applications that are clearly and explicitly ap


proved in the Project Planning Manual. If this is not the case, they are
excluded. Safety-relevant are all such applications which can cause dan
ger to persons and material damage.

The information given in the documentation of the product with regard to


the use of the delivered components contains only examples of applica
tions and suggestions.
The machine and installation manufacturer must

make sure that the delivered components are suited for his individual
application and check the information given in this documentation
with regard to the use of the components,

make sure that his application complies with the applicable safety
regulations and standards and carry out the required measures,
modifications and complements.

Commissioning of the delivered components is only permitted once it is


sure that the machine or installation in which they are installed complies
with the national regulations, safety specifications and standards of the
application.

Operation is only permitted if the national EMC regulations for the appli
cation are met.

The instructions for installation in accordance with EMC requirements can


be found in the section on EMC in the respective documentation (Project
Planning Manuals of components and system).
The machine or installation manufacturer is responsible for compliance
with the limiting values as prescribed in the national regulations.

Technical data, connection and installation conditions are specified in the


product documentation and must be followed at all times.

National regulations which the user must take into account

European countries: according to European EN standards

United States of America (USA):

National Electrical Code (NEC)

National Electrical Manufacturers Association (NEMA), as well as


local engineering regulations

regulations of the National Fire Protection Association (NFPA)

Canada: Canadian Standards Association (CSA)

Other countries:

International Organization for Standardization (ISO)

International Electrotechnical Commission (IEC)

3.1.3

Explanation of Warning Symbols and Degrees of Hazard Seriousness


The safety instructions describe the following degrees of hazard seriousness.
The degree of hazard seriousness informs about the consequences resulting
from non-compliance with the safety instructions:

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

9/315

Safety Instructions for Electric Drives and Controls

Warning symbol

Fig.3-1:

3.1.4

Signal word

Degree of hazard serious


ness acc. to ANSI Z
535.4-2002

Danger

Death or severe bodily harm


will occur.

Warning

Death or severe bodily harm


may occur.

Caution

Minor or moderate bodily


harm or material damage
may occur.

Hazard classification (according to ANSI Z 535)

Hazards by Improper Use


High electric voltage and high working current! Risk of death or severe
bodily injury by electric shock!

DANGER

Observe the safety instructions!

Dangerous movements! Danger to life, severe bodily harm or material


damage by unintentional motor movements!
DANGER

Observe the safety instructions!

High electric voltage because of incorrect connection! Risk of death or


bodily injury by electric shock!
WARNING

Observe the safety instructions!

Health hazard for persons with heart pacemakers, metal implants and
hearing aids in proximity to electrical equipment!
WARNING

Observe the safety instructions!

Hot surfaces on device housing! Danger of injury! Danger of burns!


Observe the safety instructions!

CAUTION
Risk of injury by improper handling! Risk of bodily injury by bruising,
shearing, cutting, hitting or improper handling of pressurized lines!
CAUTION

Observe the safety instructions!

10/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Safety Instructions for Electric Drives and Controls

Risk of injury by improper handling of batteries!


Observe the safety instructions!

CAUTION

3.2

Instructions with Regard to Specific Dangers

3.2.1

Protection Against Contact with Electrical Parts and Housings


This section concerns devices and drive components with voltages
of more than 50 Volt.
Contact with parts conducting voltages above 50 Volts can cause personal
danger and electric shock. When operating electrical equipment, it is unavoid
able that some parts of the devices conduct dangerous voltage.

High electrical voltage! Danger to life, electric shock and severe bodily
injury!
DANGER

Only those trained and qualified to work with or on electrical equipment


are permitted to operate, maintain and repair this equipment.

Follow general construction and safety regulations when working on pow


er installations.

Before switching on the device, the equipment grounding conductor must


have been non-detachably connected to all electrical equipment in ac
cordance with the connection diagram.

Do not operate electrical equipment at any time, even for brief measure
ments or tests, if the equipment grounding conductor is not permanently
connected to the mounting points of the components provided for this
purpose.

Before working with electrical parts with voltage potentials higher than
50 V, the device must be disconnected from the mains voltage or power
supply unit. Provide a safeguard to prevent reconnection.

With electrical drive and filter components, observe the following:


Wait 30 minutes after switching off power to allow capacitors to discharge
before beginning to work. Measure the electric voltage on the capacitors
before beginning to work to make sure that the equipment is safe to touch.

Never touch the electrical connection points of a component while power


is turned on. Do not remove or plug in connectors when the component
has been powered.

Install the covers and guards provided with the equipment properly before
switching the device on. Before switching the equipment on, cover and
safeguard live parts safely to prevent contact with those parts.

A residual-current-operated circuit-breaker or r.c.d. cannot be used for


electric drives! Indirect contact must be prevented by other means, for
example, by an overcurrent protective device according to the relevant
standards.

Secure built-in devices from direct touching of electrical parts by providing


an external housing, for example a control cabinet.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

11/315

Safety Instructions for Electric Drives and Controls


For electrical drive and filter components with voltages of more than
50 volts, observe the following additional safety instructions.

High housing voltage and high leakage current! Risk of death or bodily
injury by electric shock!
DANGER

3.2.2

Before switching on, the housings of all electrical equipment and motors
must be connected or grounded with the equipment grounding conductor
to the grounding points. This is also applicable before short tests.

The equipment grounding conductor of the electrical equipment and the


devices must be non-detachably and permanently connected to the power
supply unit at all times. The leakage current is greater than 3.5 mA.

Over the total length, use copper wire of a cross section of a minimum of
10 mm2 for this equipment grounding connection!

Before commissioning, also in trial runs, always attach the equipment


grounding conductor or connect to the ground wire. Otherwise, high vol
tages may occur at the housing causing electric shock.

Protection Against Electric Shock by Protective Extra-Low Voltage


Protective extra-low voltage is used to allow connecting devices with basic in
sulation to extra-low voltage circuits.
All connections and terminals with voltages between 5 and 50 volts at Rexroth
products are PELV systems. 1) It is therefore allowed to connect devices
equipped with basic insulation (such as programming devices, PCs, notebooks,
display units) to these connections and terminals.

High electric voltage by incorrect connection! Risk of death or bodily


injury by electric shock!
WARNING

3.2.3

If extra-low voltage circuits of devices containing voltages and circuits of more


than 50 volts (e.g. the mains connection) are connected to Rexroth products,
the connected extra-low voltage circuits must comply with the requirements for
PELV. 2)

Protection Against Dangerous Movements


Dangerous movements can be caused by faulty control of connected motors.
Some common examples are:

improper or wrong wiring of cable connections

incorrect operation of the equipment components

wrong input of parameters before operation

malfunction of sensors, encoders and monitoring devices

defective components

software or firmware errors

Dangerous movements can occur immediately after equipment is switched on


or even after an unspecified time of trouble-free operation.

1)

Protective Extra-Low Voltage

2)

Protective Extra-Low Voltage

12/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Safety Instructions for Electric Drives and Controls


The monitoring in the drive components will normally be sufficient to avoid faulty
operation in the connected drives. Regarding personal safety, especially the
danger of bodily harm and material damage, this alone cannot be relied upon
to ensure complete safety. Until the integrated monitoring functions become
effective, it must be assumed in any case that faulty drive movements will occur.
The extent of faulty drive movements depends upon the type of control and the
state of operation.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

13/315

Safety Instructions for Electric Drives and Controls

Dangerous movements! Danger to life, risk of injury, severe bodily harm


or material damage!
DANGER

Ensure personal safety by means of qualified and tested higher-level


monitoring devices or measures integrated in the installation.
These measures have to be provided for by the user according to the
specific conditions within the installation and a hazard and fault analysis.
The safety regulations applicable for the installation have to be taken into
consideration. Unintended machine motion or other malfunction is possi
ble if safety devices are disabled, bypassed or not activated.

To avoid accidents, bodily harm and/or material damage:

Keep free and clear of the machines range of motion and moving parts.
Possible measures to prevent people from accidentally entering the
machines range of motion:

use safety fences

use safety guards

use protective coverings

install light curtains or light barriers

Fences and coverings must be strong enough to resist maximum possible


momentum.

Mount the emergency stop switch in the immediate reach of the operator.
Verify that the emergency stop works before startup. Dont operate the
device if the emergency stop is not working.

Isolate the drive power connection by means of an emergency stop circuit


or use a safety related starting lockout to prevent unintentional start.

Make sure that the drives are brought to a safe standstill before accessing
or entering the danger zone.

Additionally secure vertical axes against falling or dropping after switching


off the motor power by, for example:

mechanically securing the vertical axes,

adding an external braking/ arrester/ clamping mechanism or

ensuring sufficient equilibration of the vertical axes.

The standard equipment motor brake or an external brake controlled di


rectly by the drive controller are not sufficient to guarantee personal
safety!

Disconnect electrical power to the equipment using a master switch and


secure the switch against reconnection for:

maintenance and repair work

cleaning of equipment

long periods of discontinued equipment use

Prevent the operation of high-frequency, remote control and radio equip


ment near electronics circuits and supply leads. If the use of such devices
cannot be avoided, verify the system and the installation for possible mal
functions in all possible positions of normal use before initial startup. If
necessary, perform a special electromagnetic compatibility (EMC) test on
the installation.

14/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Safety Instructions for Electric Drives and Controls

3.2.4

Protection Against Magnetic and Electromagnetic Fields During Oper


ation and Mounting
Magnetic and electromagnetic fields generated by current-carrying conductors
and permanent magnets in motors represent a serious personal danger to
those with heart pacemakers, metal implants and hearing aids.

Health hazard for persons with heart pacemakers, metal implants and
hearing aids in proximity to electrical equipment!
WARNING

3.2.5

Persons with heart pacemakers and metal implants are not permitted to
enter following areas:

Areas in which electrical equipment and parts are mounted, being


operated or commissioned.

Areas in which parts of motors with permanent magnets are being


stored, repaired or mounted.

If it is necessary for somebody with a pacemaker to enter such an area,


a doctor must be consulted prior to doing so. The noise immunity of pres
ent or future implanted heart pacemakers differs greatly so that no general
rules can be given.

Those with metal implants or metal pieces, as well as with hearing aids,
must consult a doctor before they enter the areas described above. Oth
erwise health hazards may occur.

Protection Against Contact with Hot Parts


Hot surfaces at motor housings, on drive controllers or chokes! Danger
of injury! Danger of burns!

CAUTION

3.2.6

Do not touch surfaces of device housings and chokes in the proximity of


heat sources! Danger of burns!

Do not touch housing surfaces of motors! Danger of burns!

According to the operating conditions, temperatures can be higher than


60 C, 140F during or after operation.

Before accessing motors after having switched them off, let them cool
down for a sufficiently long time. Cooling down can require up to 140 mi
nutes! Roughly estimated, the time required for cooling down is five times
the thermal time constant specified in the Technical Data.

After switching drive controllers or chokes off, wait 15 minutes to allow


them to cool down before touching them.

Wear safety gloves or do not work at hot surfaces.

For certain applications, the manufacturer of the end product, machine or


installation, according to the respective safety regulations, has to take
measures to avoid injuries caused by burns in the end application. These
measures can be, for example: warnings, guards (shielding or barrier),
technical documentation.

Protection During Handling and Mounting


In unfavorable conditions, handling and mounting certain parts and compo
nents in an improper way can cause injuries.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

15/315

Safety Instructions for Electric Drives and Controls

Risk of injury by improper handling! Bodily injury by bruising, shearing,


cutting, hitting!
CAUTION

3.2.7

Observe the general construction and safety regulations on handling and


mounting.

Use suitable devices for mounting and transport.

Avoid jamming and bruising by appropriate measures.

Always use suitable tools. Use special tools if specified.

Use lifting equipment and tools in the correct manner.

If necessary, use suitable protective equipment (for example safety gog


gles, safety shoes, safety gloves).

Do not stand under hanging loads.

Immediately clean up any spilled liquids because of the danger of skidding.

Battery Safety
Batteries consist of active chemicals enclosed in a solid housing. Therefore,
improper handling can cause injury or material damage.

Risk of injury by improper handling!


CAUTION

Do not attempt to reactivate low batteries by heating or other methods (risk


of explosion and cauterization).

Do not recharge the batteries as this may cause leakage or explosion.

Do not throw batteries into open flames.

Do not dismantle batteries.

When replacing the battery/batteries do not damage electrical parts in


stalled in the devices.

Only use the battery types specified by the manufacturer.


Environmental protection and disposal! The batteries contained in
the product are considered dangerous goods during land, air, and
sea transport (risk of explosion) in the sense of the legal regulations.
Dispose of used batteries separate from other waste. Observe the
local regulations in the country of assembly.

3.2.8

Protection Against Pressurized Systems


According to the information given in the Project Planning Manuals, motors
cooled with liquid and compressed air, as well as drive controllers, can be par
tially supplied with externally fed, pressurized media, such as compressed air,
hydraulics oil, cooling liquids and cooling lubricating agents. Improper handling
of the connected supply systems, supply lines or connections can cause injuries
or material damage.

16/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Safety Instructions for Electric Drives and Controls

Risk of injury by improper handling of pressurized lines!


CAUTION

Do not attempt to disconnect, open or cut pressurized lines (risk of explo


sion).

Observe the respective manufacturer's operating instructions.

Before dismounting lines, relieve pressure and empty medium.

Use suitable protective equipment (for example safety goggles, safety


shoes, safety gloves).

Immediately clean up any spilled liquids from the floor.


Environmental protection and disposal! The agents used to operate
the product might not be economically friendly. Dispose of ecolog
ically harmful agents separately from other waste. Observe the local
regulations in the country of assembly.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

17/315

General Specifications of the Components

General Specifications of the Components

4.1

Certifications
Declaration of Conformity

For IndraDrive components, there are declarations of conformity available


which confirm that the components have been designed according to the ap
plicable EN standards and EC Directives. If required, you can ask our sales
representative for the declarations of conformity.
Designation

Standard

CE conformity regarding Low-Voltage Direc


tive

EN61800-5-1

CE conformity regarding EMC product stand


ard

EN61800-3

listing according to UL standard (UL)


separation between control and power voltage
circuits
clearances and creepage distances

Fig.4-1:

UL 508 C
safe separation according to
EN61800-5-1
according to EN61800-5-1

Applied standards

Before making a high-voltage test and an applied-overvoltage with


stand test for the installation in which the components are used,
disconnect all connections to the devices or disconnect the plug-in
connections to protect the electronic components.
CE Label

C-UL-US Listing

Fig.4-2:

CE label

The devices have been marked with the following label:

18/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

General Specifications of the Components

C-UL-US Listed Components

Fig.4-3:

C-UL-US label

For the numbers under which the components have been UL-listed, see the
respective Project Planning Manual, chapter "Technical Data - Applied Stand
ards".
The products have been listed by Underwriters Laboratories
Inc. (UL). For evidence of certification, see on the Internet under
http://www.ul.com under Certifications by entering the file number
or the Company name: Rexroth. The file number of the product
can be found in this documentation in the section Technical Data
- Information on Standards (this example applies to HCS02).
The control sections are included in the listing of the power sections.
The control sections are not listed separately.
For using the devices in the scope of C-UL, take the C-UL limit val
ues of the individual devices into account. The C-UL limit values
can be found in the corresponding documentation in the Technical
Data - UL Data section.

CCC (China Compulsory Certifica


tion)

The CCC mark of conformity comprises a compulsory certification of safety and


quality for certain products which are mentioned in the product catalog First
Catalogue of Products Subject to Compulsory Certification and the CNCA
document Application Scope for Compulsory Certification of Products acc. first
Catalogue and which are put into circulation in China. The compulsory certifi
cation has been existing since 2003.
CNCA is the responsible Chinese authority for certification directives. When a
product is imported in China, the certification will be checked at the customs by
means of the entries in a database. For compulsory certification, three criteria
are normally relevant:
1.

Customs tariff number (HS code) according to CNCA document Appli


cation Scope for Compulsory Certification of Products acc. first Cata
logue.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

19/315

General Specifications of the Components


2.

Scope of application according to CNCA document Application Scope for


Compulsory Certification of Products acc. first Catalogue.

3.

For the IEC product standard used, there must be a corresponding Chi
nese GB standard.

For Rexroth drive components described in this documentation, certification is


not yet required, thus they have not been CCC certified. Negative certifications
will not be issued.

4.2

Transport and Storage

4.2.1

Transporting the Devices


Ambient and operating conditions - Transport

Description

Symbol

Unit

Value

Ta_tran

-25...70

relative humidity

5...95

absolute humidity

g/m3

1...60

temperature range

climatic category

2K3 (IEC721)

moisture condensation1)

icing2)

shock test when out of operation

10g / 11ms (EN60068-2-27)


1) 2)

n: not allowed; z: allowed

Fig.4-4:

4.2.2

Ambient and operating conditions - Transport

Storing the Devices


Risk of damage to the components by extended storage!

CAUTION

Some devices contain electrolytic capacitors which may deteriorate during


storage.
When storing these devices for a longer period of time, operate them once a
year for at least 1 hour with power on:

HCS and HMV devices with mains voltage ULN

HMS, HMD, HLC devices with DC bus voltage UDC

Ambient and operating conditions - Storage


Description

Symbol

Unit

Value

temperature range

Ta_store

-25...55

relative humidity

5...95

absolute humidity

g/m3

1...29

climatic category

1K3 (IEC721)

moisture condensation1)

icing2)

n
1) 2)

Fig.4-5:

n: not allowed; z: allowed

Ambient and operating conditions - Storage

20/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

General Specifications of the Components

4.3

Installation Conditions

4.3.1

Ambient and Operating Conditions


The drive controllers and their additional components have been designed for
control cabinet mounting!
The user must check that the ambient conditions, in particular the
control cabinet temperature, are complied with by calculating the
heat levels in the control cabinet and making the corresponding
measurements.
In the Technical Data of the individual components, the power dis
sipation is indicated as an important input value for calculating the
heat levels.
Ambient and operating conditions

Description

Symbol

Unit

degree of protection

IP20 (IEC529)

temperature during storage

see chapter Storing the Devices

temperature during transport

see chapter Transporting the Devices

allowed mounting position, for def


inition see chapter Positions of
Normal Use and Mounting Posi
tions
ambient temperature range

Value

see technical data of the individual components in chapter Power


Dissipation, Cooling and Distances
Ta_work

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)

0...40
0...55

see fig. Capacity utilization at higher ambient temperature in


chapter Capacity Utilization

fTa

%/K

see technical data of the individual components

nominal data up to installation alti


tude

hnenn

1000

maximum installation altitude with


out additional overvoltage limiter

hmax_ohne

2000

maximum installation altitude3)

hmax

see fig. Capacity utilization at higher installation altitude in chapter


Capacity Utilization

reduced power data above instal


lation altitude at Ta < Ta_work_red 4)

hred

1000

relative humidity

5...95

absolute humidity

g/m3

1...29

derating at Ta_work < Ta < Ta_work_red


2)

4000

climatic category

3K3 (IEC721)

allowed pollution degree

2 (EN50178)

allowed dust, steam


vibration sine: amplitude (peakpeak) at 10...57 Hz5)

EN50178 tab. A.2


mm

0,15 15 %

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

21/315

General Specifications of the Components


Description

Symbol

vibration sine: acceleration at


57...150 Hz6)
vibration noise (random) frequency
vibration noise (random) spectral
acceleration density, amplitude
vibration noise (random) rms value
of total acceleration
1)
2)
3)
4)
5) 6)

Fig.4-6:

4.3.2

Unit

Value

1 15 %

Hz

20...150 (IEC 68-2-36)

g2/Hz

0,005 3 dB (IEC 68-2-36)

1 (IEC 68-2-36)
observe derating
data to be derated: PDC_cont; PBD; Iout_cont
In the installation, install overvoltage limiter for transient overvoltages to
limit the voltage to 1 kV between the outer conductors and to 2.5 kV
between conductor-ground.
see following characteristic; observe derating
according to EN 60068-2-36

Ambient and operating conditions - Operation

Positions of Normal Use and Mounting Positions

General Information
The drive controllers and additional components may only be operated in the
allowed mounting positions. As a matter of principle, mounting position G1 is
allowed as the normal mounting position; the Technical Data apply to this po
sition.
The normal mounting position takes into account that the cooling system and
installed components, such as contactors, switches, capacitors and blowers,
work correctly.

a
g

Fig.4-7:

mounting surface
direction of gravitational force

Positions of normal use and mounting positions

Brief Description of Positions of Normal Use and Mounting Positions

G1: Normal mounting position. The natural convection supports the forced
cooling air current. This avoids the generation of pockets of heat in the

22/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

General Specifications of the Components


drive controller. G1 is the
Rexroth IndraDrive components.

4.3.3

preferred

mounting

position

G2: 180 to normal mounting position

G3: turned by 90 from vertical to horizontal mounting position

G4: bottom mounting, mounting surface on bottom of control cabinet

G5: top mounting, mounting surface at top of control cabinet

for

Compatibility with Foreign Matters


All Rexroth controls and drives are developed and tested according to the stateof-the-art technology.
As it is impossible to follow the continuing development of all materials (e.g.
lubricants in machine tools) which may interact with our controls and drives, it
cannot be completely ruled out that any reactions with the materials used by
Bosch Rexroth might occur.
For this reason, before using the respective material a compatibility test has to
be carried out for new lubricants, cleaning agents etc. and our housings/our
housing materials.

4.4

Capacity Utilization
Where installation conditions differ, the following performance data are reduced
in accordance with the diagrams:
Drive controller:

allowed DC bus continuous power PDC_cont

braking resistor continuous power PBD

continuous current Iout_cont

Motor:

power

continuous torque at standstill

S1 continuous torques

short-time service torque MKB

If differing ambient temperatures and higher installation altitudes occur simul


taneously, both capacity utilization factors must be multiplied. The installation
altitude must only be taken into account once, deviating ambient temperatures
must be taken into account separately for motor and drive controller.
Use outside of the indicated installation conditions is not allowed,
even if the performance data are additionally reduced.
Capacity Utilization vs. Ambient
Temperature

As the ambient temperature increases, the capacity utilization of the compo


nents is reduced according to the figure below.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

23/315

General Specifications of the Components

fTa
Ta work
Ta work red

Fig.4-8:

Capacity Utilization vs. Installation


Altitude

capacity utilization factor


ambient temperature range for operation with nominal data
ambient temperature range for operation with reduced nominal data

Capacity utilization at higher ambient temperature

As the installation altitude increases, the capacity utilization of the components


is reduced according to the figure below.

f
hnenn
hmax_ohne
hmax

Fig.4-9:

capacity utilization factor


maximum installation altitude for operation with nominal data
maximum installation altitude for operation with reduced nominal data
without using an overvoltage limiter
maximum installation altitude for operation with reduced nominal data
when using an overvoltage limiter

Capacity utilization at higher installation altitude

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

25/315

Power Sections for Converters - IndraDrive C

Power Sections for Converters - IndraDrive C

5.1

Types
Converter

HCS02

Types
W0012

Features

W0028

1.5 kW to 11 kW

W0054

continuous currents up to 28
A

W0070
W0070
HCS03

compact modular design

compact modular design

W0100

25 kW to 85 kW

W0150

continuous currents up to
145 A

W0210

compact modular design


HCS04 (in preparation)

Fig.5-1:

HCS02 Power Sections

5.2.1

Brief Description, Usage and Structure


Usage

up to 160 kW
continuous currents up to
200 A

Types

5.2

Brief Description

W0500

The compact converters HCS02 are part of the Rexroth IndraDrive C product
range and are used to operate single axes.
The different types are used as follows:
Type
HCS02.1E-Wxxxx-NNNN
HCS02.1E-Wxxxx-NNNV
HCS02.1E-Wxxxx-LxxN
blower control depending on load

Fig.5-2:

Usage of HCS02

Usage
Operation of a three-phase a.c. motor
(asynchronous or synchronous motor) in
the power range from 1.5 kW to 11 kW.
Applications with operation at partial load
and requirement of a low degree of noise
development.

26/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Structure, Block Diagrams

1
2

Fig.5-3:

power section
control section

Basic structure of the drive controller

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

27/315

Power Sections for Converters - IndraDrive C


HCS02.1E-W0012-NNNN; -LNNN

1)
2)
3)
4)

Fig.5-4:

mains input with rectifier


braking resistor circuit; charging current limitation
DC bus capacitances
inverter stage with output to motor

HCS02.1E-W0012-NNNN , -LNNN - block diagram

HCS02.1E-W0012-NNNV

1)
2)
3)
4)
5)

Fig.5-5:

mains input with rectifier


optional integrated control voltage supply
braking resistor circuit; charging current limitation
DC bus capacitances
inverter stage with output to motor

HCS02.1E-W0012-NNNV - block diagram

28/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


HCS02.1E-W0028-NNNN; -LNNN

1)
2)
3)
4)
5)

Fig.5-6:

mains input with rectifier


braking resistor circuit; charging current limitation
DC bus capacitances
inverter stage with output to motor
DC bus connection

HCS02.1E-W0028-NNNN; -LNNN - block diagram

HCS02.1E-W0028-NNNV

1)
2)
3)
4)
5)
6)

Fig.5-7:

mains input with rectifier


optional integrated control voltage supply
braking resistor circuit; charging current limitation
DC bus capacitances
inverter stage with output to motor
DC bus connection

HCS02.1E-W0028-NNNV - block diagram

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

29/315

Power Sections for Converters - IndraDrive C


HCS02.1E-W0054/70-NNNN; -LNNN

1)
2)
3)
4)
5)
6)

Fig.5-8:

mains input with rectifier


braking resistor circuit; charging current limitation
optional external braking resistor
DC bus capacitances
inverter stage with output to motor
DC bus connection

HCS02.1E-W0054/70-NNNN; -LNNN - block diagram

HCS02.1E-W0054/70-NNNV

1)
2)
3)
4)
5)
6)
7)

Fig.5-9:

5.2.2

mains input with rectifier


optional integrated control voltage supply
braking resistor circuit; charging current limitation
optional external braking resistor
DC bus capacitances
inverter stage with output to motor
DC bus connection

HCS02.1E-W0054/70-NNNV - block diagram

Type Code and Identification

Type Code
The following figure illustrates the basic structure of the type code.
Our sales representative will help you with the current status of
available versions.

30/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Fig.5-10:

Type code HCS02

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

31/315

Power Sections for Converters - IndraDrive C

Identification
Type Plate Arrangement

1
2

Fig.5-11:

power section type plate


control section type plate

Type plate arrangement

32/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Type Plate

1
2
3
4
5
6
7

device type
part number
serial number
bar code
country of manufacture
production week, 04W12 meaning year 2004, week 12
hardware index

Fig.5-12:

5.2.3

Type plate - power section (example of an HCS02 power section)

Scope of Supply
The scope of supply of the HCS02 power section includes

5.2.4

1 touch guard

1 connector X3, X5, X6, X13, X9 each (for designs W0054 and W0070)

1 brochure with safety instructions (in 5 languages)

Technical Data

Ambient and Operating Conditions


General Information
Conditions for transport and storage: see chapter 4.2 Transport and Storage,
page 19.
Installation conditions: see chapter 4.3 Installation Conditions , page 20.
This chapter contains:

limit values for use in the scope of C-UL

applied standards (CE conformity, UL listing)

UL Data
Ambient and operating conditions - UL ratings
Description

Symbol

Unit

HCS02.1EW0012-_-03

pollution degree (UL)

HCS02.1EW0070-_-03

Use in a pollution degree 2 environment


ISCCR

rated input voltage, power (UL)3)


maximum input current (UL)4)

HCS02.1EW0054-_-03

Use 60/75 C copper wire only, use class 1 wire only or equivalent

field wiring material (UL)1)

short circuit current rating, SCCR,


symmetrical amperes (UL)2)

HCS02.1EW0028-_-03

IL_cont

A rms

42000

200...500

10,0

16,0

20,0

32,0

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

33/315

Power Sections for Converters - IndraDrive C

Description

Symbol

Unit

maximum output voltage (UL)

Uout

maximum output current (UL)

Iout_max

1)
2)

3)
4)

Fig.5-13:

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

22,0

28,0

530
4,5

11,5

find value for tightening torque in project planning manual, Electrical


Connection Points
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
HMS, HMD, HLB, HLC: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
at PDC_cont

HCS - Ambient and operating conditions - UL ratings

Information on Standards
Applied standards
Description

Symbol

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

CE conformity regarding Low-Volt


age Directive

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

EN61800-5-1

CE conformity regarding EMC


product standard

EN61800-3

high-voltage test, test rate

100% (EN61800-5-1)

high-voltage and insulation test,


test rate

100% (EN61800-5-1)

listing according to UL standard


(UL)

UL 508 C

UL files (UL)

E 134201

listing according to CSA standard


(UL)

Canadian National Standard(s) C22.2 No. 14-05

Fig.5-14:

HCS - Applied standards

34/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Mechanical System and Mounting


Dimensional Drawings
Dimensions HCS02.1E-W0012

A
B

Fig.5-15:

minimum mounting clearance (when using accessory HAS02.1); plus


additional clearance for cable
minimum mounting clearance; plus additional clearance for cable

Dimensional drawing HCS02.1E-W0012

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

35/315

Power Sections for Converters - IndraDrive C

A
B

Fig.5-16:

minimum mounting clearance (when using accessory HAS02.1); plus


additional clearance for cable
minimum mounting clearance; plus additional clearance for cable

Dimensional drawing HCS02.1E-W0028

36/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

A
B

Fig.5-17:

minimum mounting clearance (when using accessory HAS02.1); plus


additional clearance for cable
minimum mounting clearance; plus additional clearance for cable

Dimensional drawing HCS02.1E-W0054 and HCS02.1E-W0070

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

37/315

Power Sections for Converters - IndraDrive C

Dimensions, Mass, Insulation


Data for mass, dimensions, sound pressure level, insulation
Description
Weight

Symbol

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

3,80

6,70

6,80

kg

2,90

(UL)1)

mm

290

Device depth (UL)2)

mm

(UL)3)

mm

insulation resistance at DC 500 V

Ris

MOhm

capacitance against housing

CY

nF

2 x 100

average sound pressure level (ac


curacy class 2) at PDC_cont 4)

LP

dB (A)

<70

Device height

Device width

1) 2) 3)
4)

352
206
65

105

1,00

8,00

housing dimension; see also related dimension sheet


according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent

Fig.5-18:

HCS - Data for mass, dimensions, sound pressure level, insulation

Power Dissipation, Cooling, Distances


Data for cooling and power dissipation
Description
ambient temperature range

derating at Ta_work < Ta < Ta_work_red

HCS02.1EW0028-_-03

Ta_work

0...40

0...55

%/K

2,0

fTa

allowed mounting position


cooling

HCS02.1EW0054-_-03

Unit

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)
2)

HCS02.1EW0012-_-03

Symbol

HCS02.1EW0070-_-03

G1
f

type3)

volumetric capacity of forced cool


ing4)

m3/h

allowed switching frequencies5)

fs

kHz

approx. 24

approx. 40
4, 8, 12, 16

power dissipation at Iout_cont = 0 A;


fs = fs (min.)6)

Diss_0A_fsmi

power dissipation at Iout_cont = 0 A;


fs = fs (max.)7)

Diss_0A_fsma

power dissipation at continuous


current Iout_cont and DC bus power
PDC_cont respectively (UL)8)

PDiss_cont

minimum distance on the top of the


device9)

dtop

mm

25

35

85

70

110

195

185

80,00

130,00

270,00

300,00

P
x

80

38/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Description

HCS02.1EW0012-_-03

Symbol

Unit

minimum distance on the bottom of


the device10)

dbot

mm

temperature rise with minimum dis


tances dbot; dtop; PBD

12

temperature rise with minimum dis


tances dbot; dtop; cooling air current
fails; PBD

80

1)
2)
3)
4)
5)
6) 7)
8)
9) 10)

Fig.5-19:

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03
80
40

90

50

100

110

observe derating
data to be derated: PDC_cont; PBD; Iout_cont
n: natural convection; f: forced cooling
HLR: see following note regarding cooling
also depending on firmware and control section; see parameter de
scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS); find interim values by interpolation to P_Diss_cont
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS)
see fig. "Air intake and air outlet at drive controller"

HCS - Data for cooling and power dissipation

Property damage due to temperatures higher than 105 C!


Comply with indicated minimum distances!

CAUTION

HCS02.1EW0070-_-03

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

39/315

Power Sections for Converters - IndraDrive C

A
B
C
dtop
dbot

Fig.5-20:

Power Dissipation vs. Output Cur


rent

air intake
air outlet
mounting surface in control cabinet
distance top
distance bottom

Air intake and air outlet at drive controller

The figure below illustrates the connection between power dissipation and out
put current, depending on the switching frequency fs which was set at the drive
controller. See also Parameter Description "P-0-0001, Switching frequency of
the power output stage".
In addition, take the power at the braking resistor and the power
consumption of the control section into account. Both powers are
not contained in the figure.

40/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Fig.5-21:

Power dissipation vs. output current

Basic Data Power Section HCS02


General Information
This section contains

data for control voltage supply

data for mains voltage supply

data of DC bus

data of built-in braking resistor and requirements on an external braking


resistor

data of inverter

data for cooling and power dissipation


The order of the data tables below follows the energy flow in the
drive controller - from mains connection to motor output.

Control Voltage
Data for control voltage supply
Description

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

Symbol

Unit

rated control voltage input (UL)1)

UN3

24 20 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length < 50 m2)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length > 50 m3)

UN3

26 5 %

maximum ripple content4)

HCS02.1EW0070-_-03

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

41/315

Power Sections for Converters - IndraDrive C


HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

Description

Symbol

Unit

maximum allowed voltage for


1 ms5)

UN3_max

33,00

inrush current at 24V supply

IEIN3

2,80

pulse width of IEIN3

tEIN3Lade

ms

15

input capacitance

CN3

mF

1.2 x 0.47

rated power consumption control


voltage input without holding brake,
without control section at
UN3 = DC 24 V (UL)6)

PN3

internal control voltage (optional)7)

Ucontr_int

1) 2) 3)
4)
5)
6)
7)

12

14

HCS02.1EW0070-_-03

23

24 10 %
observe supply voltage for motor holding brakes
absolute voltage values must be within UN3
see following note regarding overvoltage
find value for control section in project planning manual
value only with HCS02, HCS03: Types with order code -***V

Fig.5-22:

HCS - Data for control voltage supply

Overvoltage of more than 33 V has to be discharged by means of


the appropriate electrical equipment of the machine or installation.
This includes:

Control Voltage Block Diagram

24V power supply units that reduce incoming overvoltage to


the allowed value.

Overvoltage limiters at the control cabinet input that limit ex


isting overvoltage to the allowed value. This, too, applies to
long 24V lines that have been run in parallel to power cables
and mains cables and can absorb overvoltage by inductive or
capacitive coupling.

The control voltage applied via connection X13 acts according to the block di
agram below.

BR
LT
ST
ZK
int. SMPS

Fig.5-23:

circuit for brake control


power section, e.g. HCS02
control section, e.g CSB01
DC bus
internal switching power supply unit, for types HCS0x.1E-Wxxxx-NxxV

Block diagram of internal control voltage

42/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Mains Voltage
Data for mains voltage supply
Description
input frequency (UL)

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

Unit

fLN

Hz

50...60

Hz

Hz/s

tolerance input frequency (UL)


maximum allowed mains frequen
cy change

HCS02.1EW0012-_-03

Symbol

fLN/t

rotary field condition


short circuit current rating, SCCR,
symmetrical amperes (UL)1)

ISCCR

A rms

42000

ULN_nenn

3 AC 400

mains voltage single-phase

ULN

200...250

mains voltage three-phase at TN S,


TN C, TT mains

ULN

200...500

mains voltage three-phase at IT


mains

ULN

200...230

mains voltage three-phase at Cor


ner-grounded-Delta mains2)

ULN

200...230

10

40

nominal mains voltage

tolerance ULN (UL)


minimum inductance of the mains
supply (inductance of mains
phase)3)

Lmin

assigned type of mains choke, type


of mains filter combination
minimum short circuit power of the
mains for failure-free operation4)

HCS02.1EW0070-_-03

HNL01.1E-100 HNL01.1E-060
0-N00200-N0032A-500-NNNN
A-500-NNNN

HNL01.1E-1000-N0012-A-500NNNN
Sk_min

MVA

0,2

0,4

0,6

0,8

1,4...4,3

3,5...10,7

6,3...19,3

9,9...27,5

0,75

0,76

0,64

0,56

I
maximum inrush current5)

L_trans_max_
on

maximum allowed ON-Off cycles


per minute6)

power factor TPF (L) at PDC_cont


with mains choke; ULN_nenn

TPF

power factor TPF (L) at PDC_cont


without mains choke; ULN_nenn 7)

TPF

power factor TPF (L) at 10%


PDC_cont without mains choke;
ULN_nenn 8)
power factor TPF (L) at PDC_cont
(single-phase); ULN = 1 AC 230 V

0,70
0,60

TPF10

0,40

TPF

0,40

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

43/315

Power Sections for Converters - IndraDrive C


HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

7,30

13,30

18,50

3,50

8,50

11,00

16,00

10,0

16,0

20,0

32,0

HCS02.1EW0028-_-03

16; gL

20; gL

25; gL

35; gL

3RT1016

3RT1025

3RT1026

3RT1034

1,5

2,5

AWG 12

AWG 10

Symbol

power factor of fundam. compo


nent DPF at PDC_cont with mains
choke9)

cosh1

0,95

power factor of fundam. compo


nent DPF at PDC_cont without mains
choke10)

cosh1

0,97

mains connection power at


PDC_cont; ULN_nenn with mains choke

SLN

kVA

3,50

mains connection power at


PDC_cont; ULN_nenn without mains
choke

SLN

kVA

maximum input current (UL)11)

IL_cont

recommended mains fuse at nom.


data with mains choke; ULN_nenn

Unit

HCS02.1EW0012-_-03

Description

recommended mains contactor at


nom. data with mains choke;
ULN_nenn 12)
required wire size according to
IEC 60364552; at IL_cont 13)

ALN

required wire size according to


UL 508 A (internal wiring); at IL_cont
(UL)14)

ALN
1)

2)
3)
4)
5)
6)
7) 8)
9) 10)
11)
12)
13)
14)

Fig.5-24:

mm2

AWG 14

Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
mains voltage > ULN: use a transformer with grounded neutral point,
dont use autotransformers!
otherwise use mains choke HNL
HMV0x.xR: Rsc=100; HMV0x.xE, HCS0x.xE: Rsc=50
depending on mains input voltage ULN; HMV01.1R see following note;
HMV: constant current charge, HCS: resistance charge; minimum of
250.000 load cycles
without external capacities on DC bus
find interim values by interpolation
c: leading reactive; i: reactive
at PDC_cont
i: mains contactor integrated
copper wire; PVC-insulation (conductor temperature 70 C); installation
method B2; Table B52-4; Ta 40 C
copper wire; PVC-insulation (conductor temperature 90 C); Table
13.5.1; Ta 40 C

HCS - Data for mains voltage supply

44/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Qualitative characteristic TPF vs. DC bus power PDC_cont

1
2

characteristic with mains choke


characteristic without mains choke

Fig.5-25:

Qualitative characteristic TPF vs. DC bus power PDC_cont

DC Bus
Data of power section - DC bus
Description

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

Symbol

Unit

UDC

ULN x 1,41

UDC_nenn

CDC

mF

tentl_ZK

sec.

storable energy of internal DC bus


capacitance4)

WDC

Ws

DC resistance in DC bus (L+ to L-)


at UDC = 750 V

RDC

ohm

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; with mains choke5)

PDC_cont

kW

2,10

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; without mains choke6)

PDC_cont

kW

2,10

changing PDC_cont and PDC_max vs.


mains input voltage; ULN ULN_nenn

fP_DC_lo

%/V

DC bus voltage range1)


nominal value of regulated DC bus
voltage2)
capacitance in DC bus
maximum discharge time from
UR_DC_On to DC 50 V3)

0,14

0,27

HCS02.1EW0070-_-03

0,54

0,68

57,00

95,00

5,10

10,00

14,00

5,10

7,00

9,00

tbd
19,00

38,00
tbd

0,25

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

45/315

Power Sections for Converters - IndraDrive C


HCS02.1EW0012-_-03

Description

Symbol

Unit

changing PDC_cont and PDC_max vs.


mains input voltage; ULN > ULN_nenn

fP_DC_hi

%/V

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; with mains
choke7)

PDC_max

kW

5,00

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; without mains
choke8)

PDC_max

kW

5,00

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

10,00

16,00

19,00

8,00

12,00

14,00

0,20

balancing factor for PDC_cont (for


parallel operation at common DC
bus) with mains choke

0,80

balancing factor for PDC_cont (for


parallel operation at common DC
bus) without mains choke

0,50

monitoring value maximum DC bus


voltage, switch-off threshold9)

DC_limit_max

monitoring value minimum DC bus


voltage, undervoltage threshold10)

DC_limit_min

charging resistor continuous power

PDC_Start

kW

0,05

0,15

0,35

0,50

maximum allowed external DC bus


capacitance

CDCext

mF

5,00

7,00

13,00

9,00

13,00

charging time at maximum allowed


CDCext external DC bus capacitance
at ULN_nenn
maximum allowed DC bus charg
ing energy to external capacitors

900

t
lade_DC_Cex

sec.

tbd

Wmax
1)
2)
3)
4)
5) 6)
7) 8)
9)
10)

Fig.5-26:

kWs

1,00

5,00

depending on mains input voltage ULN


only devices with regulated DC bus voltage
without other device on DC bus
at ULN_nenn to UR_DC_On
observe factors f Ta; f P_DC; HMV: without fs; without fout
observe factors f Ta; f P_DC
HMV: see also troubleshooting guide for E8025, F2817
HMV: see also troubleshooting guide for E2026, F2026; HCS: Depend
ing on parameter setting, see parameter description "P00114, Under
voltage threshold"

HCS - Data of power section - DC bus

46/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

fP_DC_hi
fP_DC_lo

factor in range ULN>ULNnenn


factor in range ULNULNnenn

Characteristic of DC bus continuous power PDC versus mains connec


tion voltage ULN

Fig.5-27:
Single-Phase Mains Connection

Single-phase mains connection


Single-phase mains connection is carried out via the connections
L1 and L2.
Observe that the max. allowed DC bus power PDC_max is limited to
the specified continuous power PDC_cont.
Data of power section with single-phase mains connection

Description
mains voltage single-phase
continuous power (t > 10 min)

Symbol

Unit

ULN

PDC_cont

Fig.5-28:

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

200...250
50...70

100...160

150...250

260...400

HCS - Data of power section with single-phase mains connection

Braking Resistor
Data of built-in braking resistor
Symbol

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

braking resistor continuous power1)

PBD

kW

0,05

0,15

0,35

0,50

braking resistor peak power at


UDC = 850 V2)

PBS

kW

4,00

10,00

18,00

25,00

ohm

180

72

40

28

ohm

188

75

40

31

Description

nominal braking resistance


maximum braking resistance at
PBD
braking resistor switch-on thresh
old - mains voltage independent3)

RDC_Bleed
er

RDC_Bleed
er

UR_DC_On_f

820

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

47/315

Power Sections for Converters - IndraDrive C

Description

Symbol

braking resistor switch-on thresh


old - mains voltage dependent4)

R_DC_On_v

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

maximum allowed duty cycle at


Tcycl

EDrel

0,25

minimum allowed cycle time

Tcycl

20,00

33,00

26,00

25,00

maximum regenerative power to be


absorbed

WR_max

kWs

1,00

5,00

9,00

13,00

balancing factor for PBD (for parallel


operation at common DC bus)

0,50

0,80
f

cooling of internal braking resistor5)


1)
2)
3) 4)

observe derating factor f Ta; 0 kW when ext. braking resistor is used


0: no internal braking resistor; 0 kW when ext. braking resistor is used
factory setting; with HCS see parameter description "P-0-0833, Braking
resistor threshold" and "P-0-0860, Converter configuration"; with HMV
see X32
n: natural convection; f: forced cooling

5)

Fig.5-29:

HCS - Data of built-in braking resistor

Requirements on external braking resistor


Description

Symbol

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

minimum required resistance value RDC_Bleed


of external braking resistor1)
er

ohm

40,0

28,0

minimum required peak power of


external braking resistor at
UDC = 850 V2)

kW

18,00

25,00

HLR01.1N-01
K8-N40R0;
HLR01.1N-03
K8-N40R0

HLR01.1N-02
K4-N28R0;
HLR01.1N-05
K5-N28R0

PBS

assigned braking resistor type


HLR013)
1) 2)
3)

see parameter description "P00858, Data of external braking resistor"


see also project planning manual "Additional Components"; see param
eter description "P00858, Data of external braking resistor"

Fig.5-30:

HCS - Requirements on external braking resistor

Inverter
Data of power section - Inverter
Description

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

Symbol

Unit

fs

kHz

4, 8, 12, 16

output voltage, fundamental wave


with open-loop operation

Uout_eff

~ UDC x 0,71

output voltage, fundamental wave


with closed-loop operation

Uout_eff

~ UDC * 0,71

allowed switching frequencies1)

HCS02.1EW0070-_-03

48/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Description

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

Symbol

Unit

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-phase (1090%)2)

du/dt

kV/s

5,00

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-ground (1090%)3)

du/dt

kV/s

5,00

output frequency range at fs = 2 kHz

fout_2k

Hz

output frequency range at fs = 4 kHz

fout_4k

Hz

0...400

output frequency range at fs = 8 kHz

fout_8k

Hz

0..800

output frequency range at


fs = 12 kHz

fout_12k

Hz

0..1200

output frequency range at


fs = 16 kHz

fout_16k

Hz

0...1600

maximum output current at


fs = 2 kHz

Iout_max2

maximum output current at


fs = 4 kHz

Iout_max4

11,5

28,3

54,0

70,8

maximum output current at


fs = 8 kHz

Iout_max8

11,5

28,3

54,0

70,8

maximum output current at


fs = 12 kHz

Iout_max12

11,5

28,3

54,0

70,8

maximum output current at


fs = 16 kHz

Iout_max16

11,5

28,3

54,0

70,8

allowed continuous output current


at fs = 2 kHz

Iout_cont2

allowed continuous output current


at fs = 4 kHz

Iout_cont4

4,5

12,0

20,6

28,0

allowed continuous output current


at fs = 8 kHz

Iout_cont8

4,5

9,2

20,6

21,4

allowed continuous output current


at fs = 12 kHz4)

Iout_cont12

4,0

5,1

13,8

14,1

allowed continuous output current


at fs = 16 kHz5)

Iout_cont16

2,8

4,4

11,1

10,5

allowed continuous output current


at fs = 2 kHz; output frequency
fout < fout_still
allowed continuous output current
at fs = 4 kHz; output frequency
fout < fout_still

I
out_cont0Hz_

I
out_cont0Hz_
4

4,5

9,7

20,2

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

49/315

Power Sections for Converters - IndraDrive C

Description

Symbol

allowed continuous output current


at fs = 8 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 12 kHz; output frequency
fout < fout_still 6)

out_cont0Hz_

allowed continuous output current


at fs = 16 kHz; output frequency
fout < fout_still 7)

out_cont0Hz_

output frequency threshold to de


tect motor standstill8)

fout_still

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

3,3

5,6

13,1

11,9

1,2

2,3

7,5

6,7

0,7

2,1

6,1

4,2

I
8

I
12

I
16

Hz

2...4

assigned output filters at nom. da


ta; fs = 4 kHz

tbd
1)
2) 3)
4) 5) 6) 7)
8)

Fig.5-31:

also depending on firmware and control section; see parameter de


scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
guide value, see following note
see parameter description "P00556, Config word of axis controller",
load-depending reduction of PWM frequency fs
see following note regarding reduction output current

HCS - Data of power section - Inverter

Observe that the load is almost independent of the power section


used.
Especially when using standard motors , make sure that they com
ply with the occurring voltage load.
Observe the information contained in the chapter Third-Party Mo
tors at IndraDrive Controllers in the Project Planning Manual of the
drive system.
Depending on the electric output frequency, the output current is
reduced for thermal protection of the power section.
The output current is reduced, when the electric output frequency
has fallen below the threshold to detect motor standstill.

Exemplary Data for Applications


General Information
This section contains

examples of allowed current profiles

examples of allowed performance profiles

data for selecting standard motors

50/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Current Profiles
Examples of allowed current profiles
HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

24,29

41,66

56,56

3,63

9,72

16,66

22,62

9,07

15,06

33,59

34,77

base load current at Iout_peak_1;


Iout_base1_8
fs = 8 kHz; t = 0,4 s; T = 4 s; K = 2,5

3,63

6,02

13,43

13,91

maximum output current at


Iout_base_1; fs = 12 kHz; t = 0,4 s;
T = 4 s; K = 2,54)

6,03

8,42

21,96

23,12

2,41

3,37

8,78

9,25

4,25

7,29

17,77

17,16

1,70

2,92

7,11

6,86

Description

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

Symbol

Unit

Iout_peak1_2

base load current at Iout_peak_1;


Iout_base1_2
fs = 2 kHz; t = 0,4 s; T = 4 s; K = 2,5

maximum output current at


Iout_base_1; fs = 4 kHz; t = 0,4 s;
T = 4 s; K = 2,52)

Iout_peak1_4

9,07

base load current at Iout_peak_1;


Iout_base1_4
fs = 4 kHz; t = 0,4 s; T = 4 s; K = 2,5

maximum output current at


Iout_base_1; fs = 8 kHz; t = 0,4 s;
T = 4 s; K = 2,53)

Iout_peak1_8

maximum output current at


Iout_base_1; fs = 2 kHz; t = 0,4 s;
T = 4 s; K = 2,51)

base load current at Iout_peak_1;


fs = 12 kHz; t = 0,4 s; T = 4 s; K = 2,5
maximum output current at
Iout_base_1; fs = 16 kHz; t = 0,4 s;
T = 4 s; K = 2,55)
base load current at Iout_peak_1;
fs = 16 kHz; t = 0,4 s; T = 4 s; K = 2,5

I
out_peak1_12

I
out_base1_12

I
out_peak1_16

I
out_base1_16

maximum output current at


Iout_base_3; fs = 2 kHz; t = 2 s; T = 20 s; Iout_peak3_2
K = 2,06)

base load current at Iout_peak_3;


Iout_base3_2
fs = 2 kHz; t = 2 s; T = 20 s; K = 2,0

maximum output current at


Iout_base_3; fs = 4 kHz; t = 2 s; T = 20 s; Iout_peak3_4
K = 2,07)

7,79

20,90

35,86

48,68

base load current at Iout_peak_3;


Iout_base3_4
fs = 4 kHz; t = 2 s; T = 20 s; K = 2,0

3,90

10,45

17,93

24,34

maximum output current at


Iout_base_3; fs = 8 kHz; t = 2 s; T = 20 s; Iout_peak3_8
K = 2,08)

7,79

13,55

30,54

31,36

base load current at Iout_peak_3;


Iout_base3_8
fs = 8 kHz; t = 2 s; T = 20 s; K = 2,0

3,90

6,77

15,27

15,68

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

51/315

Power Sections for Converters - IndraDrive C

Description
maximum output current at
Iout_base_3; fs = 12 kHz; t = 2 s;
T = 20 s; K = 2,09)
base load current at Iout_peak_3;
fs = 12 kHz; t = 2 s; T = 20 s; K = 2,0
maximum output current at
Iout_base_3; fs = 16 kHz; t = 2 s;
T = 20 s; K = 2,010)
base load current at Iout_peak_3;
fs = 16 kHz; t = 2 s; T = 20 s; K = 2,0

Symbol
I
out_peak3_12

I
out_base3_12

I
out_peak3_16

I
out_base3_16

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

5,57

7,56

19,88

20,81

2,78

3,78

9,94

10,40

3,90

6,55

16,06

15,42

1,95

3,27

8,03

7,71

base load current at Iout_peak_4;


Iout_base4_2
fs = 2 kHz; t = 60 s; T = 5 min; K = 1,5

maximum output current at


Iout_base_4; fs = 2 kHz; t = 60 s;
T = 5 min; K = 1,511)

Iout_peak4_2

maximum output current at


Iout_base_4; fs = 4 kHz; t = 60 s;
T = 5 min; K = 1,512)

Iout_peak4_4

5,22

14,79

25,13

33,74

base load current at Iout_peak_4;


Iout_base4_4
fs = 4 kHz; t = 60 s; T = 5 min; K = 1,5

3,48

9,86

16,76

22,49

maximum output current at


Iout_base_4; fs = 8 kHz; t = 60 s;
T = 5 min; K = 1,513)

Iout_peak4_8

5,22

10,25

22,97

24,33

base load current at Iout_peak_4;


Iout_base4_8
fs = 8 kHz; t = 60 s; T = 5 min; K = 1,5

3,48

6,83

15,32

16,22

maximum output current at


Iout_base_4; fs = 12 kHz; t = 60 s;
T = 5 min; K = 1,514)

4,32

5,71

14,88

16,10

2,88

3,81

9,92

10,74

3,02

4,95

12,00

11,93

2,01

3,30

8,00

7,95

base load current at Iout_peak_4;


fs = 12 kHz; t = 60 s; T = 5 min;
K = 1,5
maximum output current at
Iout_base_4; fs = 16 kHz; t = 60 s;
T = 5 min; K = 1,515)
base load current at Iout_peak_4;
fs = 16 kHz; t = 60 s; T = 5 min;
K = 1,5

I
out_peak4_12

I
out_base4_12

I
out_peak4_16

I
out_base4_16

maximum output current at


Iout_base_5; fs = 2 kHz; t = 60 s;
T = 10 min; K = 1,116)

Iout_peak5_2

base load current at Iout_peak_5;


fs = 2 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_2

52/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Symbol

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

maximum output current at


Iout_base_5; fs = 4 kHz; t = 60 s;
T = 10 min; K = 1,117)

Iout_peak5_4

4,70

12,75

21,82

29,55

base load current at Iout_peak_5;


fs = 4 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_4

4,27

11,59

19,84

26,87

maximum output current at


Iout_base_5; fs = 8 kHz; t = 60 s;
T = 10 min; K = 1,118)

Iout_peak5_8

4,70

9,46

21,79

22,20

base load current at Iout_peak_5;


fs = 8 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_8

4,27

8,60

19,81

20,18

4,14

5,27

14,10

14,68

3,76

4,79

12,82

13,35

2,89

4,57

11,37

10,87

2,63

4,15

10,33

9,88

Description

maximum output current at


Iout_base_5; fs = 12 kHz; t = 60 s;
T = 10 min; K = 1,119)
base load current at Iout_peak_5;
fs = 12 kHz; t = 60 s; T = 10 min;
K = 1,1
maximum output current at
Iout_base_5; fs = 16 kHz; t = 60 s;
T = 10 min; K = 1,120)
base load current at Iout_peak_5;
fs = 16 kHz; t = 60 s; T = 10 min;
K = 1,1

I
out_peak5_12

I
out_base5_12

I
out_peak5_16

I
out_base5_16

1) 2) 3) 4) 5) 6) see definition profile UEL_I_e


7) 8) 9) 10)
11) 12) 13)
14) 15) 16)
17) 18) 19)
20)

Fig.5-32:
Current Profile UEL_I_e

HCS - Examples of allowed current profiles

The following current profiles have been defined for converters and inverters.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

53/315

Power Sections for Converters - IndraDrive C

Profile
Current profile UEL_I_e

Explanation

The characteris
tic data of the
profile are used
to select convert
ers and inverters
for operation with
standard motors
and servo drives.

Fig.5-33:

Definition of current profiles

Performance Profiles
Examples of allowed performance profiles
Symbol

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 0,4 s;
T = 4 s; K = 2,5;
PDC_peak = PDC_max; without mains
choke1)

PDC_peak_1

kW

4,25

10,33

14,17

18,19

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 0,4 s;
T = 4 s; K = 2,5;
PDC_peak = PDC_max; with mains
choke2)

PDC_peak_1

kW

20,24

28,30

DC bus power at ULN_nenn;


Ta Ta_work; t =0,4 s; T = 4 s; K = 2,5;
PDC_base_1
PDC_peak = PDC_max; without mains
choke3)

kW

5,67

7,26

DC bus power at ULN_nenn;


Ta Ta_work; t = 0,4 s; T = 4 s;
K = 2,5; PDC_peak = PDC_max; with
mains choke4)

PDC_base_1

kW

8,11

11,30

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 2 s;
T = 20 s; K = 2,0; without mains
choke5)

PDC_peak_3

kW

12,19

15,65

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 2 s;
T = 20 s; K = 2,0; with mains
choke6)

PDC_peak_3

kW

17,41

24,34

Description

1,68

4,12

3,64

8,88

54/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

DC bus power at ULN_nenn;


Ta Ta_work; t = 2 s; T = 20 s; K = 2,0; PDC_base_3
without mains choke7)

kW

1,82

4,44

6,09

7,82

DC bus power at ULN_nenn;


Ta Ta_work; t = 2 s; T = 20 s; K = 2,0; PDC_base_3
with mains choke8)

kW

8,70

12,17

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
T = 5 min; K = 1,5; without mains
choke9)

PDC_peak_4

kW

8,54

10,85

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
T = 5 min; K = 1,5; with mains
choke10)

PDC_peak_4

kW

12,20

16,87

DC bus power at ULN_nenn;


Ta Ta_work; t = 60 s; T = 5 min;
K = 1,5; without mains choke11)

PDC_base_4

kW

5,70

7,23

DC bus power at ULN_nenn;


Ta Ta_work; t = 60 s; T = 5 min;
K = 1,5; with mains choke12)

PDC_base_4

kW

8,14

11,25

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
PDC_peak_5
T = 10 min; K = 1.1; without mains
choke13)

kW

7,41

9,50

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
T = 10 min; K = 1.1; with mains
choke14)

PDC_peak_5

kW

10,59

14,78

DC bus power at ULN_nenn;


Ta Ta_work; t = 60 s; T = 10 min;
K = 1.1; without mains choke15)

PDC_base_5

kW

6,74

8,64

DC bus power at ULN_nenn;


Ta Ta_max; t = 60 s; T = 10 min;
K = 1,1; with mains choke16)

PDC_base_5

kW

9,63

13,44

Description

Symbol

2,44

6,29

1,62

4,19

2,19

5,42

1,99

4,93

1) 2) 3) 4) 5) 6) see definition profile UEL_P_e


7) 8) 9) 10)
11) 12) 13)
14) 15) 16)

Fig.5-34:
Performance Profile UEL_P_e

HCS - Examples of allowed performance profiles

The following performance profiles have been defined for converters and in
verters.
Observe the allowed performance data PDC_peak and PDC_base in the
corresponding performance profile of the supply unit or converter.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

55/315

Power Sections for Converters - IndraDrive C

Profile
Performance profile UEL_P_e

Explanation

Characteristic of
the selection of
standard motors
and servo drives.

Fig.5-35:

Definition of performance profiles, infeeding supply units and converters

Operation With Standard Motors


General Information
Selecting Standard Motors

The tables below contain the nominal power Pnenn of standard motors which
can be operated at the respective drive controller. The data are subject to the
following conditions:

motor design:
4-pole standard motor (2 pole pairs) with rated voltage 3AC400V, 50Hz at
mains voltage ULN 3AC400V or
4-pole standard motor (2 pole pairs) with rated voltage 3AC460V, 60Hz at
mains voltage ULN 3AC460V

assigned mains choke is used

operation at minimum switching frequency fs= fs (min.)

rotary field at output with fout>fout_still

ambient temperature TaTa_work

overload ratio K=PDC_peak/PDC_base according to performance profile


UEL_P_e

type of mains connection: individual supply


When choosing standard motors for HMS/HMD, additionally select
an appropriate HMV supply unit. Observe the performance data
PDC_peak and PDC_base in the performance profile UEL_P_e of the
supply unit.

56/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Operating Standard Motors at 3 AC 400 V


Selection of standard motors 3 AC 400V - Exemplary profiles
Symbol

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

nominal power standard motor


3 AC 400 V; 50 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

1,50

4,00

7,50

11,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

1,50

4,00

7,50

11,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

1,10

4,00

5,50

11,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

1,10

3,00

5,50

7,50

Description

1) 2) 3) 4)

see definition profile UEL_P_e


HCS - Selection of standard motors 3 AC 400V - Exemplary profiles

Fig.5-36:

Operating Standard Motors at 3 AC 460 V


Selection of standard motors 3 AC 460V - Exemplary profiles
Symbol

Unit

HCS02.1EW0012-_-03

HCS02.1EW0028-_-03

HCS02.1EW0054-_-03

HCS02.1EW0070-_-03

nominal power standard motor


3AC460V; 60 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

1,50

4,00

7,50

11,00

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

1,50

4,00

7,50

11,00

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

1,50

4,00

7,50

11,00

nominal power standard motor


3AC460V; 60 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

1,50

3,70

7,50

11,00

Description

1) 2) 3) 4)

Fig.5-37:

see definition profile UEL_P_e; 1 kW ~ 1,36 hp


HCS - Selection of standard motors 3 AC 460V - Exemplary profiles

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

57/315

Power Sections for Converters - IndraDrive C

5.2.5

Connections and Interfaces

Overview
Overall Connection Diagram

X1, L+/LX9

Fig.5-38:

not available for HCS02.1E-W0012


not available for HCS02.1E-W0012 and W0028

Overall connection diagram

58/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Apart from the indicated connections, it is necessary to wire the Bb
contact at the control section for signaling the readiness for opera
tion of the drive controller (see Project Planning Manual for Control
Section).

Arrangement of the Connection Points


Connection points power section HCS02.1E-W0012 (front)

X13
XS1

Fig.5-39:

control voltage
shield connection control lines

Connection points power section HCS02.1E-W0012 (front)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

59/315

Power Sections for Converters - IndraDrive C


Connection points power section HCS02.1E-W0012 (bottom)

X3
X5
X6
XS2

Fig.5-40:

mains connection
motor connection
motor temperature monitoring, motor holding brake
shield connection motor cable

Connection points power section HCS02.1E-W0012 (bottom)

60/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Connection points power sections HCS02.1E-W0028, -W0054, W0070 (front)

X1
X13
XS1
L+, L-

Fig.5-41:

module bus
control voltage
shield connection control lines
DC bus

Connection points power sections HCS02.1E-W0028, -W0054, W0070


(front)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

61/315

Power Sections for Converters - IndraDrive C


Connection points power section HCS02.1E-W0028 (bottom)

X3
X5
X6
XS2

Fig.5-42:

mains connection
motor connection
motor temperature monitoring, motor holding brake
shield connection motor cable

Connection points power section HCS02.1E-W0028 (bottom)

62/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Connection points power sections HCS02.1E-W0054, -W0070 (bottom)

X3
X5
X6
X9
XS2

Fig.5-43:

mains connection
motor connection
motor temperature monitoring, motor holding brake
external braking resistor
shield connection motor cable

Connection points power sections HCS02.1E-W0054, -W0070 (bottom)

Lethal electric shock caused by live parts with more than 50 V!


Via the connection X3 (mains connection), connect the drive controller to the
equipment grounding conductor system.

DANGER

Description of the Connection Points


The connection points are described in detail in chapter 8 Functions and Elec
trical Connection Points , page 255.
Touch Guard

The touch guard is described in detail in chapter 9 Touch Guard at Devices ,


page 299.

5.3

HCS03 Power Sections

5.3.1

Brief Description, Usage and Structure


Brief Description
Usage

The compact converters HCS03 are part of the Rexroth IndraDrive C product
range and are used to operate single axes.
The different types are used as follows:

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

63/315

Power Sections for Converters - IndraDrive C


Type

Usage

HCS03.1E-Wxxxx-NNNV

Operation of a three-phase a.c. motor


(asynchronous or synchronous motor).

HCS03.1E-Wxxxx-NNBV
HCS03.1E-Wxxxx-LNNV
HCS03.1E-Wxxxx-LNBV
blower control depending on load

Fig.5-44:

Usage of HCS03

1
2

power section
control section

Applications with operation at partial load


and requirement of a low degree of noise
development.

Structure, Block Diagrams

Fig.5-45:

Basic structure of the drive controller

64/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


HCS03.1E-...-NNNV; -LNxV

1)
2)
3)
5)
6)
7)

Fig.5-46:

mains input with rectifier


integrated control voltage supply
charging current limitation, for -W0210 with thyristors
DC bus capacitances
inverter stage with output to motor
DC bus connection

HCS03.1E-...-NNNV - block diagram

HCS03.1E-...-NNBV; -LNBV

1)
2)
3)
4)
5)
6)
7)
8)

Fig.5-47:

5.3.2

mains input with rectifier


integrated control voltage supply
charging current limitation, for -W0210 with thyristors
optional braking transistor
optional external braking resistor
DC bus capacitances
inverter stage with output to motor
DC bus connection

HCS03.1E-...-NNBV - block diagram

Type Code and Identification

Type Code
The following illustrations show the general structure of the type
codes. Our sales representative will help you with the current status
of available versions.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

65/315

Power Sections for Converters - IndraDrive C

Fig.5-48:

Type code HCS03.1

66/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Identification
Type Plate Arrangement

Type Plate

1
2

power section type plate


control section type plate

1
2
3
4
5
6
7

device type
part number
serial number
bar code
country of manufacture
production week, 04W12 meaning year 2004, week 12
hardware index

Fig.5-49:

Fig.5-50:

5.3.3

Type plate arrangement

Type plate - power section (example of an HCS02 power section)

Scope of Supply
The scope of supply of the power section includes

1 touch guard

1 connector X3 (only for design W0070)

1 connector X5 (only for design W0070)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

67/315

Power Sections for Converters - IndraDrive C

5.3.4

1 connector X6

1 connector X9 (for designs -xxBx)

1 brochure with safety instructions (in 5 languages)

Technical Data

Ambient and Operating Conditions


General Information
Conditions for transport and storage: see chapter 4.2 Transport and Storage,
page 19.
Installation conditions: see chapter 4.3 Installation Conditions , page 20.
This chapter contains:

limit values for use in the scope of C-UL

applied standards (CE conformity, UL listing)

UL Data
Ambient and operating conditions - UL ratings
Description

Symbol

HCS03.1EW0070-_-05

Unit

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

Use 60/75 C copper wire only, use class 1 wire only or equivalent

field wiring material (UL)1)


pollution degree (UL)
short circuit current rating, SCCR,
symmetrical amperes (UL)2)

HCS03.1EW0100-_-05

Use in a pollution degree 2 environment


ISCCR

rated input voltage, power (UL)3)

A rms

42000

400...500

maximum input current (UL)4)

IL_cont

maximum output voltage (UL)

Uout

maximum output current (UL)

Iout_max

1)
2)

3)
4)

Fig.5-51:

50,0

80,0

106,0

146,0

95,0

145,0

480
45,0

75,0

find value for tightening torque in project planning manual, Electrical


Connection Points
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
HMS, HMD, HLB, HLC: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
at PDC_cont

HCS - Ambient and operating conditions - UL ratings

Information on Standards
Applied standards
Description
CE conformity regarding Low-Volt
age Directive
CE conformity regarding EMC
product standard
high-voltage test, test rate

Symbol

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

EN61800-5-1
EN61800-3
100% (EN61800-5-1)

HCS03.1EW0210-_-05

68/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Description

Symbol

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

high-voltage and insulation test,


test rate

100% (EN61800-5-1)

listing according to UL standard


(UL)

UL 508 C

UL files (UL)

E 227957

listing according to CSA standard


(UL)

HCS03.1EW0210-_-05

Canadian National Standard(s) C22.2 No. 14-05

Fig.5-52:

HCS - Applied standards

Mechanical System and Mounting


Dimensional Drawings
Dimensional drawing HCS03.1E-W0070

Fig.5-53:

Dimensional drawing HCS03.1E-W0070

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

69/315

Power Sections for Converters - IndraDrive C


Dimensional drawing HCS03.1E-W0070 with HAS02

Fig.5-54:

Dimensional drawing HCS03.1E-W0070 with HAS02

70/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Dimensional drawing HCS03.1E-W0100 and HCS03.1E-W150

Fig.5-55:

Dimensional drawing HCS03.1E-W0100 and HCS03.1E-W150

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

71/315

Power Sections for Converters - IndraDrive C


Dimensional drawing HCS03.1E-W0100 and HCS03.1E-W150 with HAS02

Fig.5-56:

Dimensional drawing HCS03.1E-W0100 and HCS03.1E-W150 with


HAS02

72/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Dimensional drawing HCS03.1E-W0210

Fig.5-57:

Dimensional drawing HCS03.1E-W0210

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

73/315

Power Sections for Converters - IndraDrive C


Dimensional drawing HCS03.1E-W0210 with HAS02

Fig.5-58:

Dimensional drawing HCS03.1E-W0210 with HAS02

74/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Boring dimensions HCS03.1E-W0070

Fig.5-59:

Boring dimensions HCS03.1E-W0070

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

75/315

Power Sections for Converters - IndraDrive C


Boring dimensions HCS03.1E-W0100 and HCS03.1-W0150

Fig.5-60:

Boring dimensions HCS03.1E-W0100 and HCS03.1-W0150

76/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Boring dimensions HCS03.1E-W0210

Fig.5-61:

Boring dimensions HCS03.1E-W0210

Dimensions, Mass, Insulation, Sound Pressure Level


Data for mass, dimensions, sound pressure level, insulation
Symbol

Unit

HCS03.1EW0070-_-05

Weight

kg

13,00

Device height (UL)1)

mm

490

Device depth (UL)2)

mm

262

Device width (UL)3)

mm

Description

125

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

20,00

225

HCS03.1EW0210-_-05
38,00

350

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

77/315

Power Sections for Converters - IndraDrive C

Description

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

Symbol

Unit

insulation resistance at DC 500 V

Ris

MOhm

11,00

capacitance against housing

CY

nF

2 x 100

average sound pressure level (ac


curacy class 2) at PDC_cont 4)

LP

dB (A)

1) 2) 3)
4)

<70

HCS03.1EW0210-_-05

<75

housing dimension; see also related dimension sheet


according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent

Fig.5-62:

HCS - Data for mass, dimensions, sound pressure level, insulation

Power Dissipation, Cooling, Distances


Data for cooling and power dissipation
Description
ambient temperature range

derating at Ta_work < Ta < Ta_work_red

HCS03.1EW0100-_-05

Ta_work

0...40

0...55

%/K

2,0

fTa

allowed mounting position


cooling

HCS03.1EW0150-_-05

Unit

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)
2)

HCS03.1EW0070-_-05

Symbol

HCS03.1EW0210-_-05

G1
f

type3)

volumetric capacity of forced cool


ing4)

m3/h

allowed switching frequencies5)

fs

kHz

265,00

367,00

780,00

4, 8, 12, 16

power dissipation at Iout_cont = 0 A;


fs = fs (min.)6)

Diss_0A_fsmi

power dissipation at Iout_cont = 0 A;


fs = fs (max.)7)

Diss_0A_fsma

power dissipation at continuous


current Iout_cont and DC bus power
PDC_cont respectively (UL)8)

PDiss_cont

minimum distance on the top of the


device9)

dtop

mm

80

minimum distance on the bottom of


the device10)

dbot

mm

100

P
-

800,00

950,00

1150,00

2000,00

78/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Description

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

Symbol

Unit

temperature rise with minimum dis


tances dbot; dtop; PBD

30

temperature rise with minimum dis


tances dbot; dtop; cooling air current
fails; PBD

tbd

1)
2)
3)
4)
5)
6) 7)
8)
9) 10)

Fig.5-63:

observe derating
data to be derated: PDC_cont; PBD; Iout_cont
n: natural convection; f: forced cooling
HLR: see following note regarding cooling
also depending on firmware and control section; see parameter de
scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS); find interim values by interpolation to P_Diss_cont
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS)
see fig. "Air intake and air outlet at drive controller"

HCS - Data for cooling and power dissipation

Property damage due to temperatures higher than 105 C!


Comply with indicated minimum distances!

CAUTION

HCS03.1EW0210-_-05

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

79/315

Power Sections for Converters - IndraDrive C

A
B
C
dtop
dbot

Fig.5-64:

Power Dissipation vs. Output Cur


rent

air intake
air outlet
mounting surface in control cabinet
distance top
distance bottom

Air intake and air outlet at drive controller

The figure below illustrates the connection between power dissipation and out
put current, depending on the switching frequency fs which was set at the drive
controller. See also Parameter Description "P-0-0001, Switching frequency of
the power output stage".
In addition, take the power at the braking resistor and the power
consumption of the control section into account. Both powers are
not contained in the figure.

80/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Fig.5-65:

Power dissipation vs. output current

Basic Data Power Section HCS03


General Information
This section contains

data for control voltage supply

data for mains voltage supply

data of DC bus

data of built-in braking resistor and requirements on an external braking


resistor

data of inverter

data for cooling and power dissipation


The order of the data tables below follows the energy flow in the
drive controller - from mains connection to motor output.

Control Voltage
Data for control voltage supply
Description

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

Symbol

Unit

rated control voltage input (UL)1)

UN3

24 20 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length < 50 m2)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length > 50 m3)

UN3

26 5 %

maximum ripple content4)

HCS03.1EW0210-_-05

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

81/315

Power Sections for Converters - IndraDrive C


HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

Description

Symbol

Unit

maximum allowed voltage for


1 ms5)

UN3_max

33,00

inrush current at 24V supply

IEIN3

2,80

pulse width of IEIN3

tEIN3Lade

ms

input capacitance

CN3

mF

1.2 x 0.47

rated power consumption control


voltage input without holding brake,
without control section at
UN3 = DC 24 V (UL)6)

PN3

internal control voltage (optional)7)

Ucontr_int

1) 2) 3)
4)
5)
6)
7)

22

HCS03.1EW0210-_-05

25

30

observe supply voltage for motor holding brakes


absolute voltage values must be within UN3
see following note regarding overvoltage
find value for control section in project planning manual
value only with HCS02, HCS03: Types with order code -***V

Fig.5-66:

HCS - Data for control voltage supply

Overvoltage of more than 33 V has to be discharged by means of


the appropriate electrical equipment of the machine or installation.
This includes:

24V power supply units that reduce incoming overvoltage to


the allowed value.

Overvoltage limiters at the control cabinet input that limit ex


isting overvoltage to the allowed value. This, too, applies to
long 24V lines that have been run in parallel to power cables
and mains cables and can absorb overvoltage by inductive or
capacitive coupling.

Mains Voltage
Data for mains voltage supply
Description
input frequency (UL)

HCS03.1EW0150-_-05

fLN

Hz

50...60

Hz

Hz/s

fLN/t

rotary field condition


short circuit current rating, SCCR,
symmetrical amperes (UL)1)

HCS03.1EW0100-_-05

Unit

tolerance input frequency (UL)


maximum allowed mains frequen
cy change

HCS03.1EW0070-_-05

Symbol

ISCCR

A rms

42000

ULN_nenn

3 AC 400

mains voltage single-phase

ULN

mains voltage three-phase at TN S,


TN C, TT mains

ULN

400...500

nominal mains voltage

HCS03.1EW0210-_-05

82/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Description

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

Symbol

Unit

mains voltage three-phase at IT


mains

ULN

mains voltage three-phase at Cor


ner-grounded-Delta mains2)

ULN

10

40

tolerance ULN (UL)


minimum inductance of the mains
supply (inductance of mains
phase)3)

Lmin

HNL01.1E-057 HNL01.1E-036 HNL01.1E-024 HNL01.1E-017


1-N00502-N00800-N01060-N0146A-500-NNNN
A-500-NNNN
A-500-NNNN
A-500-NNNN

assigned type of mains choke, type


of mains filter combination
minimum short circuit power of the
mains for failure-free operation4)

HCS03.1EW0210-_-05

Sk_min

MVA

1,1

2,80

2,0

2,7

3,8

I
maximum inrush current5)

L_trans_max_

5,70

17,00

on

maximum allowed ON-Off cycles


per minute6)

power factor TPF (L) at PDC_cont


with mains choke; ULN_nenn

TPF

0,85

0,83

0,81

0,78

power factor TPF (L) at PDC_cont


without mains choke; ULN_nenn 7)

TPF

0,57

0,59

0,61

0,62

0,94

0,93

power factor TPF (L) at 10%


PDC_cont without mains choke;
ULN_nenn 8)
power factor TPF (L) at PDC_cont
(single-phase); ULN = 1 AC 230 V

TPF10

0,40

TPF

power factor of fundam. compo


nent DPF at PDC_cont with mains
choke9)

cosh1

power factor of fundam. compo


nent DPF at PDC_cont without mains
choke10)

cosh1

mains connection power at


PDC_cont; ULN_nenn with mains choke

SLN

mains connection power at


PDC_cont; ULN_nenn without mains
choke
maximum input current (UL)11)
recommended mains fuse at nom.
data with mains choke; ULN_nenn

0,95

0,64

0,67

0,70

0,73

kVA

35,00

55,20

72,90

99,30

SLN

kVA

22,60

40,30

54,00

76,00

IL_cont

50,0

80,0

106,0

146,0

63; gR

100; aR

125; gR

200; gR

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

83/315

Power Sections for Converters - IndraDrive C

Description

Symbol

Unit

recommended mains contactor at


nom. data with mains choke;
ULN_nenn 12)
required wire size according to
IEC 60364552; at IL_cont 13)

ALN

required wire size according to


UL 508 A (internal wiring); at IL_cont
(UL)14)

ALN
1)

2)
3)
4)
5)
6)
7) 8)
9) 10)
11)
12)
13)
14)

Fig.5-67:

mm2

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

3RT1036

3RT1044

3RT1046

3RT1055

16

35

50

95

AWG 8

AWG 4

AWG 2

AWG 1/0

Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
mains voltage > ULN: use a transformer with grounded neutral point,
dont use autotransformers!
otherwise use mains choke HNL
HMV0x.xR: Rsc=100; HMV0x.xE, HCS0x.xE: Rsc=50
depending on mains input voltage ULN; HMV01.1R see following note;
HMV: constant current charge, HCS: resistance charge; minimum of
250.000 load cycles
without external capacities on DC bus
find interim values by interpolation
c: leading reactive; i: reactive
at PDC_cont
i: mains contactor integrated
copper wire; PVC-insulation (conductor temperature 70 C); installation
method B2; Table B52-4; Ta 40 C
copper wire; PVC-insulation (conductor temperature 90 C); Table
13.5.1; Ta 40 C

HCS - Data for mains voltage supply

Qualitative characteristic TPF vs. DC bus power PDC_cont

1
2

Fig.5-68:

characteristic with mains choke


characteristic without mains choke

Qualitative characteristic TPF vs. DC bus power PDC_cont

84/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

DC Bus
Data of power section - DC bus
Description

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

Symbol

Unit

UDC

ULN x 1,41

UDC_nenn

CDC

mF

tentl_ZK

sec.

storable energy of internal DC bus


capacitance4)

WDC

Ws

DC resistance in DC bus (L+ to L-)


at UDC = 750 V

RDC

ohm

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; with mains choke5)

PDC_cont

kW

25,00

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; without mains choke6)

PDC_cont

kW

13,00

changing PDC_cont and PDC_max vs.


mains input voltage; ULN ULN_nenn

fP_DC_lo

%/V

0,25

changing PDC_cont and PDC_max vs.


mains input voltage; ULN > ULN_nenn

fP_DC_hi

%/V

0,20

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; with mains
choke7)

PDC_max

kW

40,00

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; without mains
choke8)

PDC_max

kW

20,00

DC bus voltage range1)


nominal value of regulated DC bus
voltage2)
capacitance in DC bus
maximum discharge time from
UR_DC_On to DC 50 V3)

0,94

1,44

1,88

4,70

300,00

752,00

43,00

56,00

85,00

24,00

34,00

47,00

59,00

89,00

124,00

33,00

54,00

68,00

tbd
150,00

230,00
tbd

balancing factor for PDC_cont (for


parallel operation at common DC
bus) with mains choke

1,00

balancing factor for PDC_cont (for


parallel operation at common DC
bus) without mains choke

0,80
U

monitoring value maximum DC bus


voltage, switch-off threshold9)

DC_limit_max

monitoring value minimum DC bus


voltage, undervoltage threshold10)

DC_limit_min

charging resistor continuous power

PDC_Start

HCS03.1EW0210-_-05

900

400

kW

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

85/315

Power Sections for Converters - IndraDrive C

Description

Symbol

Unit

maximum allowed external DC bus


capacitance

CDCext

mF

charging time at maximum allowed


CDCext external DC bus capacitance
at ULN_nenn

lade_DC_Cex

maximum allowed DC bus charg


ing energy to external capacitors

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05
50 (HWI >01)

t
sec.

tbd

kWs

tbd

Wmax
1)
2)
3)
4)
5) 6)
7) 8)
9)
10)

Fig.5-69:

fP_DC_hi
fP_DC_lo

Fig.5-70:

depending on mains input voltage ULN


only devices with regulated DC bus voltage
without other device on DC bus
at ULN_nenn to UR_DC_On
observe factors f Ta; f P_DC; HMV: without fs; without fout
observe factors f Ta; f P_DC
HMV: see also troubleshooting guide for E8025, F2817
HMV: see also troubleshooting guide for E2026, F2026; HCS: Depend
ing on parameter setting, see parameter description "P00114, Under
voltage threshold"

HCS - Data of power section - DC bus

factor in range ULN>ULNnenn


factor in range ULNULNnenn

Characteristic of DC bus continuous power PDC versus mains connec


tion voltage ULN

86/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

External Braking Resistor


Requirements on external braking resistor
Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

minimum required resistance value RDC_Bleed


of external braking resistor1)
er

ohm

17,5

11,7

7,0

5,0

minimum required peak power of


external braking resistor at
UDC = 850 V2)

kW

Description

Symbol

PBS

tbd

assigned braking resistor type


HLR013)

HLR01.1N-030 HLR01.1N-047 HLR01.1N-078 HLR01.1N-1K


0-N17R5
0-N11R7
0-N07R0
08-N05R0
1) 2)
3)

see parameter description "P00858, Data of external braking resistor"


see also project planning manual "Additional Components"; see param
eter description "P00858, Data of external braking resistor"

Fig.5-71:

HCS - Requirements on external braking resistor

Inverter
Data of power section - Inverter
Description

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

Symbol

Unit

fs

kHz

4, 8, 12, 16

output voltage, fundamental wave


with open-loop operation

Uout_eff

~ UDC x 0,71

output voltage, fundamental wave


with closed-loop operation

Uout_eff

~ UDC * 0,71

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-phase (1090%)2)

du/dt

kV/s

5,00

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-ground (1090%)3)

du/dt

kV/s

5,00

output frequency range at fs = 2 kHz

fout_2k

Hz

output frequency range at fs = 4 kHz

fout_4k

Hz

0...400

output frequency range at fs = 8 kHz

fout_8k

Hz

0..800

output frequency range at


fs = 12 kHz

fout_12k

Hz

0..1200

output frequency range at


fs = 16 kHz

fout_16k

Hz

0...1600

maximum output current at


fs = 2 kHz

Iout_max2

maximum output current at


fs = 4 kHz

Iout_max4

70,0

100,0

150,0

210,0

maximum output current at


fs = 8 kHz

Iout_max8

62,0

86,0

137,0

190,0

allowed switching frequencies1)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

87/315

Power Sections for Converters - IndraDrive C

Description

Symbol

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

maximum output current at


fs = 12 kHz

Iout_max12

47,0

60,0

105,0

135,0

maximum output current at


fs = 16 kHz

Iout_max16

34,0

50,0

86,0

105,0

allowed continuous output current


at fs = 2 kHz

Iout_cont2

allowed continuous output current


at fs = 4 kHz

Iout_cont4

45,0

73,0

95,0

145,0

allowed continuous output current


at fs = 8 kHz

Iout_cont8

33,0

50,0

66,0

100,0

allowed continuous output current


at fs = 12 kHz4)

Iout_cont12

24,0

37,0

48,0

72,0

allowed continuous output current


at fs = 16 kHz5)

Iout_cont16

18,0

27,0

37,0

54,0

allowed continuous output current


at fs = 2 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 4 kHz; output frequency
fout < fout_still
allowed continuous output current
at fs = 8 kHz; output frequency
fout < fout_still
allowed continuous output current
at fs = 12 kHz; output frequency
fout < fout_still 6)

I
A

I
out_cont0Hz_

29,2

46,9

60,9

92,5

18,3

30,4

39,6

57,8

12,0

20,8

27,4

38,3

8,6

15,0

20,0

27,9

I
out_cont0Hz_
8

I
out_cont0Hz_
12

allowed continuous output current


at fs = 16 kHz; output frequency
fout < fout_still 7)

out_cont0Hz_

output frequency threshold to de


tect motor standstill8)

fout_still

I
16

assigned output filters at nom. da


ta; fs = 4 kHz

Hz

2...4
tbd

1)
2) 3)
4) 5) 6) 7)
8)

Fig.5-72:

also depending on firmware and control section; see parameter de


scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
guide value, see following note
see parameter description "P00556, Config word of axis controller",
load-depending reduction of PWM frequency fs
see following note regarding reduction output current

HCS - Data of power section - Inverter

88/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C


Observe that the load is almost independent of the power section
used.
Especially when using standard motors , make sure that they com
ply with the occurring voltage load.
Observe the information contained in the chapter Third-Party Mo
tors at IndraDrive Controllers in the Project Planning Manual of the
drive system.
Depending on the electric output frequency, the output current is
reduced for thermal protection of the power section.
The output current is reduced, when the electric output frequency
has fallen below the threshold to detect motor standstill.

Exemplary Data for Applications


General Information
This section contains

examples of allowed current profiles

examples of allowed performance profiles

data for selecting standard motors

Current Profiles
examples of allowed current profiles
HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

100,00

150,00

210,00

28,00

40,00

60,00

84,00

56,29

78,09

116,46

169,54

base load current at Iout_peak_1;


Iout_base1_8
fs = 8 kHz; t = 0,4 s; T = 4 s; K = 2,5

22,52

31,24

46,58

67,81

maximum output current at


Iout_base_1; fs = 12 kHz; t = 0,4 s;
T = 4 s; K = 2,54)

41,49

57,08

85,83

122,51

16,60

22,83

34,33

49,00

Description

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

Symbol

Unit

Iout_peak1_2

base load current at Iout_peak_1;


Iout_base1_2
fs = 2 kHz; t = 0,4 s; T = 4 s; K = 2,5

maximum output current at


Iout_base_1; fs = 4 kHz; t = 0,4 s;
T = 4 s; K = 2,52)

Iout_peak1_4

70,00

base load current at Iout_peak_1;


Iout_base1_4
fs = 4 kHz; t = 0,4 s; T = 4 s; K = 2,5

maximum output current at


Iout_base_1; fs = 8 kHz; t = 0,4 s;
T = 4 s; K = 2,53)

Iout_peak1_8

maximum output current at


Iout_base_1; fs = 2 kHz; t = 0,4 s;
T = 4 s; K = 2,51)

base load current at Iout_peak_1;


fs = 12 kHz; t = 0,4 s; T = 4 s; K = 2,5

I
out_peak1_12

I
out_base1_12

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

89/315

Power Sections for Converters - IndraDrive C

Description
maximum output current at
Iout_base_1; fs = 16 kHz; t = 0,4 s;
T = 4 s; K = 2,55)
base load current at Iout_peak_1;
fs = 16 kHz; t = 0,4 s; T = 4 s; K = 2,5

Symbol
I
out_peak1_16

I
out_base1_16

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

31,31

42,79

65,24

92,58

12,52

17,12

26,10

37,03

maximum output current at


Iout_base_3; fs = 2 kHz; t = 2 s; T = 20 s; Iout_peak3_2
K = 2,06)

base load current at Iout_peak_3;


Iout_base3_2
fs = 2 kHz; t = 2 s; T = 20 s; K = 2,0

maximum output current at


Iout_base_3; fs = 4 kHz; t = 2 s; T = 20 s; Iout_peak3_4
K = 2,07)

66,15

91,81

135,86

210,00

base load current at Iout_peak_3;


Iout_base3_4
fs = 4 kHz; t = 2 s; T = 20 s; K = 2,0

33,07

45,91

67,93

105,00

maximum output current at


Iout_base_3; fs = 8 kHz; t = 2 s; T = 20 s; Iout_peak3_8
K = 2,08)

47,56

63,92

95,46

148,43

base load current at Iout_peak_3;


Iout_base3_8
fs = 8 kHz; t = 2 s; T = 20 s; K = 2,0

23,78

31,96

47,73

74,22

maximum output current at


Iout_base_3; fs = 12 kHz; t = 2 s;
T = 20 s; K = 2,09)

34,94

46,52

70,06

106,87

17,47

23,26

35,03

53,44

26,33

34,78

53,13

80,58

13,17

17,39

26,57

40,29

base load current at Iout_peak_3;


fs = 12 kHz; t = 2 s; T = 20 s; K = 2,0
maximum output current at
Iout_base_3; fs = 16 kHz; t = 2 s;
T = 20 s; K = 2,010)
base load current at Iout_peak_3;
fs = 16 kHz; t = 2 s; T = 20 s; K = 2,0

I
out_peak3_12

I
out_base3_12

I
out_peak3_16

I
out_base3_16

base load current at Iout_peak_4;


Iout_base4_2
fs = 2 kHz; t = 60 s; T = 5 min; K = 1,5

maximum output current at


Iout_base_4; fs = 2 kHz; t = 60 s;
T = 5 min; K = 1,511)

Iout_peak4_2

maximum output current at


Iout_base_4; fs = 4 kHz; t = 60 s;
T = 5 min; K = 1,512)

Iout_peak4_4

47,66

75,04

108,03

162,72

base load current at Iout_peak_4;


Iout_base4_4
fs = 4 kHz; t = 60 s; T = 5 min; K = 1,5

31,77

50,02

72,02

108,48

90/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Symbol

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

Iout_peak4_8

34,02

51,94

75,38

112,29

base load current at Iout_peak_4;


Iout_base4_8
fs = 8 kHz; t = 60 s; T = 5 min; K = 1,5

22,68

34,62

50,26

74,86

maximum output current at


Iout_base_4; fs = 12 kHz; t = 60 s;
T = 5 min; K = 1,514)

24,90

37,66

55,12

80,57

16,60

25,10

36,75

53,71

18,73

28,08

41,70

60,61

12,49

18,72

27,80

40,41

Description
maximum output current at
Iout_base_4; fs = 8 kHz; t = 60 s;
T = 5 min; K = 1,513)

base load current at Iout_peak_4;


fs = 12 kHz; t = 60 s; T = 5 min;
K = 1,5
maximum output current at
Iout_base_4; fs = 16 kHz; t = 60 s;
T = 5 min; K = 1,515)
base load current at Iout_peak_4;
fs = 16 kHz; t = 60 s; T = 5 min;
K = 1,5

I
out_peak4_12

I
out_base4_12

I
out_peak4_16

I
out_base4_16

maximum output current at


Iout_base_5; fs = 2 kHz; t = 60 s;
T = 10 min; K = 1,116)

Iout_peak5_2

base load current at Iout_peak_5;


fs = 2 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_2

maximum output current at


Iout_base_5; fs = 4 kHz; t = 60 s;
T = 10 min; K = 1,117)

Iout_peak5_4

46,36

73,69

98,64

150,11

base load current at Iout_peak_5;


fs = 4 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_4

42,14

66,99

89,67

136,47

maximum output current at


Iout_base_5; fs = 8 kHz; t = 60 s;
T = 10 min; K = 1,118)

Iout_peak5_8

33,06

50,97

68,66

103,39

base load current at Iout_peak_5;


fs = 8 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_8

30,05

46,34

62,42

93,99

24,20

36,95

50,13

74,09

22,00

33,59

45,57

67,36

maximum output current at


Iout_base_5; fs = 12 kHz; t = 60 s;
T = 10 min; K = 1,119)
base load current at Iout_peak_5;
fs = 12 kHz; t = 60 s; T = 10 min;
K = 1,1

I
out_peak5_12

I
out_base5_12

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

91/315

Power Sections for Converters - IndraDrive C

Description
maximum output current at
Iout_base_5; fs = 16 kHz; t = 60 s;
T = 10 min; K = 1,120)
base load current at Iout_peak_5;
fs = 16 kHz; t = 60 s; T = 10 min;
K = 1,1

Symbol
I
out_peak5_16

I
out_base5_16

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

18,20

27,55

37,90

55,70

16,54

25,05

34,45

50,64

1) 2) 3) 4) 5) 6) see definition profile UEL_I_e


7) 8) 9) 10)
11) 12) 13)
14) 15) 16)
17) 18) 19)
20)

Fig.5-73:
Current Profile UEL_I_e

HCS - Examples of allowed current profiles

The following current profiles have been defined for converters and inverters.
Profile
Current profile UEL_I_e

Explanation

The characteris
tic data of the
profile are used
to select convert
ers and inverters
for operation with
standard motors
and servo drives.

Fig.5-74:

Definition of current profiles

Performance Profiles
Examples of allowed performance profiles
Symbol

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 0,4 s;
T = 4 s; K = 2,5;
PDC_peak = PDC_max; without mains
choke1)

PDC_peak_1

kW

20,22

32,88

53,68

68,07

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 0,4 s;
T = 4 s; K = 2,5;
PDC_peak = PDC_max; with mains
choke2)

PDC_peak_1

kW

38,89

58,90

88,42

123,10

Description

92/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

DC bus power at ULN_nenn;


Ta Ta_work; t =0,4 s; T = 4 s; K = 2,5;
PDC_base_1
PDC_peak = PDC_max; without mains
choke3)

kW

8,09

13,15

21,47

27,23

DC bus power at ULN_nenn;


Ta Ta_work; t = 0,4 s; T = 4 s;
K = 2,5; PDC_peak = PDC_max; with
mains choke4)

PDC_base_1

kW

15,56

23,56

35,37

49,24

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 2 s;
T = 20 s; K = 2,0; without mains
choke5)

PDC_peak_3

kW

19,20

30,18

48,64

68,07

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 2 s;
T = 20 s; K = 2,0; with mains
choke6)

PDC_peak_3

kW

36,75

54,04

80,09

123,10

DC bus power at ULN_nenn;


Ta Ta_work; t = 2 s; T = 20 s; K = 2,0; PDC_base_3
without mains choke7)

kW

9,56

15,09

24,30

34,03

DC bus power at ULN_nenn;


Ta Ta_work; t = 2 s; T = 20 s; K = 2,0; PDC_base_3
with mains choke8)

kW

18,37

27,04

40,04

61,55

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
T = 5 min; K = 1,5; without mains
choke9)

PDC_peak_4

kW

13,78

24,66

38,65

52,74

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
T = 5 min; K = 1,5; with mains
choke10)

PDC_peak_4

kW

26,48

44,20

63,68

95,39

DC bus power at ULN_nenn;


Ta Ta_work; t = 60 s; T = 5 min;
K = 1,5; without mains choke11)

PDC_base_4

kW

9,90

16,44

25,77

35,17

DC bus power at ULN_nenn;


Ta Ta_work; t = 60 s; T = 5 min;
K = 1,5; with mains choke12)

PDC_base_4

kW

17,65

29,46

42,45

63,59

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
PDC_peak_5
T = 10 min; K = 1.1; without mains
choke13)

kW

13,40

23,23

35,29

48,65

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
T = 10 min; K = 1.1; with mains
choke14)

kW

25,76

43,41

58,15

88,00

Description

Symbol

PDC_peak_5

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

93/315

Power Sections for Converters - IndraDrive C

Symbol

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

DC bus power at ULN_nenn;


Ta Ta_work; t = 60 s; T = 10 min;
K = 1.1; without mains choke15)

PDC_base_5

kW

12,16

22,03

32,10

44,24

DC bus power at ULN_nenn;


Ta Ta_max; t = 60 s; T = 10 min;
K = 1,1; with mains choke16)

PDC_base_5

kW

23,41

39,46

52,86

80,00

Description

1) 2) 3) 4) 5) 6) see definition profile UEL_P_e


7) 8) 9) 10)
11) 12) 13)
14) 15) 16)

Fig.5-75:
Performance Profile UEL_P_e

HCS - Examples of allowed performance profiles

The following performance profiles have been defined for converters and in
verters.
Observe the allowed performance data PDC_peak and PDC_base in the
corresponding performance profile of the supply unit or converter.
Profile
Performance profile UEL_P_e

Explanation

Characteristic of
the selection of
standard motors
and servo drives.

Fig.5-76:

Definition of performance profiles, infeeding supply units and converters

Operation With Standard Motors


General Information
Selecting Standard Motors

The tables below contain the nominal power Pnenn of standard motors which
can be operated at the respective drive controller. The data are subject to the
following conditions:

motor design:
4-pole standard motor (2 pole pairs) with rated voltage 3AC400V, 50Hz at
mains voltage ULN 3AC400V or
4-pole standard motor (2 pole pairs) with rated voltage 3AC460V, 60Hz at
mains voltage ULN 3AC460V

assigned mains choke is used

operation at minimum switching frequency fs= fs (min.)

rotary field at output with fout>fout_still

94/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

ambient temperature TaTa_work

overload ratio K=PDC_peak/PDC_base according to performance profile


UEL_P_e

type of mains connection: individual supply


When choosing standard motors for HMS/HMD, additionally select
an appropriate HMV supply unit. Observe the performance data
PDC_peak and PDC_base in the performance profile UEL_P_e of the
supply unit.

Operating Standard Motors at 3 AC 400 V


Selection of standard motors 3 AC 400V - Exemplary profiles
Symbol

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

nominal power standard motor


3 AC 400 V; 50 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

18,50

37,00

45,00

75,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

18,50

30,00

45,00

75,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

15,00

22,00

37,00

55,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

15,00

22,00

37,00

55,00

Description

1) 2) 3) 4)

see definition profile UEL_P_e


HCS - Selection of standard motors 3 AC 400V - Exemplary profiles

Fig.5-77:

Operating Standard Motors at 3 AC 460 V


Selection of standard motors 3 AC 460V - Exemplary profiles
Symbol

Unit

HCS03.1EW0070-_-05

HCS03.1EW0100-_-05

HCS03.1EW0150-_-05

HCS03.1EW0210-_-05

nominal power standard motor


3AC460V; 60 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

22,00

45,00

55,00

75,00

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

22,00

37,00

55,00

75,00

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

18,50

30,00

37,00

55,00

nominal power standard motor


3AC460V; 60 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

18,50

22,00

37,00

55,00

Description

1) 2) 3) 4)

Fig.5-78:

see definition profile UEL_P_e; 1 kW ~ 1,36 hp


HCS - Selection of standard motors 3 AC 460V - Exemplary profiles

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

95/315

Power Sections for Converters - IndraDrive C

5.3.5

Connections and Interfaces

Overview
Overall Connection Diagram

Fig.5-79:

Overall connection diagram

96/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

Arrangement of the Connection Points

Fig.5-80:

Connections at power section HCS03.1

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

97/315

Power Sections for Converters - IndraDrive C


No
.

Description

Design

module bus X1

ribbon cable

no

The module bus connection is only neces


sary, if a converter of identical performance
or an inverter is connected to L+ and L-.

1.1

parking position X1

bars

yes (for compli


ance with UL
terms and utiliza
tion of integrated
safety technolo
gy)

Connection of an external 24 V supply is on


ly necessary, if an external mains contactor
or a holding brake is used. If connection with
bars is not possible, short twisted wires may
be used as an alternative.

control voltage; +24V and 0 V

Connection obli
Note on terminal description
gatory?

DC bus; L+ and L-

bars

no

Connection is only necessary, if two con


verters of identical performance are to be
linked via the DC bus or if an inverter is con
nected. If connection with bars is impossi
ble, lines may be used as an alternative.

equipment grounding conductor

joint bar

yes

If connection with joint bar is impossible,


lines may be used as an alternative.

motor (X5)

yes

4 connections: A1, A2, A3, equipment


grounding conductor

yes

Alternatively, shield connection can be real


ized via the mounting plate available as an
option.

motor temperature monitoring


and motor holding brake (X6)

shielded cable or
shielded motor ca
ble with integrated
connection cable
for X6

no

This connection is only required, if the motor


is equipped with temperature monitoring
function and/or holding brake and if these
functions are to be used.

mains

single cores or 4core non-metallicsheathed cable

yes

braking resistor

single cores

no

motor cable shield

shielded motor ca
ble

Fig.5-81:

Connections at power section HCS03.1

98/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Converters - IndraDrive C

X3
X5
X6

Fig.5-82:

mains
motor
motor temperature, motor holding brake

Connections at power section (bottom) HCS03.1E-W0070

Description of the Connection Points


The connection points are described in detail in chapter 8 Functions and Elec
trical Connection Points , page 255.
Touch Guard

The touch guard is described in detail in chapter 9 Touch Guard at Devices ,


page 299.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

99/315

Power Sections for Inverters - IndraDrive M

Power Sections for Inverters - IndraDrive M

6.1

Types
Inverter

Types
W0012

Features

W0028
HMS01.1N

W0054

compact modular design

W0070

continuous currents up to
145 A

W0110
W0150
W0210
W0012
HMD01.1N

compact modular design

W0020

continuous currents up to 20
A

W0036

compact modular design

Fig.6-1:

W0054

HMS01 Power Sections

6.2.1

Brief Description, Usage and Structure


Usage

minor mounting dimensions


than HMS01

Overview of inverter types

6.2

Brief Description

continuous currents up to 25
A

W0028

HMS02.1N

The HMS01 inverters are part of the Rexroth IndraDrive M product range and
are used to operate single axes.
The different types are used as follows:
Type

Usage

HMS01.1N-Wxxxx-NNNN

single-axis device

Operation of a three-phase a.c. mo


tor (asynchronous or synchronous
motor).

Fig.6-2:

Usage of HMS01

100/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Structure, Block Diagrams

1
2

Fig.6-3:

power section
control section

Basic structure of the drive controller

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

101/315

Power Sections for Inverters - IndraDrive M

1)
2)

Fig.6-4:

6.2.2

inverter stage with output to motor


DC bus connection

HMS01 - block diagram

Type Code and Identification

Type Code
The following figure illustrates the basic structure of the type code.
Our sales representative will help you with the current status of
available versions.

102/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Fig.6-5:

Type code HMS01

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

103/315

Power Sections for Inverters - IndraDrive M

Identification
Type Plate Arrangement

1
2
3

Fig.6-6:

power section type plate


control section type plate
firmware type plate

Type plates at the drive controller

104/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Type Plate

1
2
3
4
5
6
7

device type
part number
serial number
bar code
country of manufacture
production week, 04W12 meaning year 2004, week 12
hardware index

Fig.6-7:

6.2.3

Type plate - power section (example of an HCS02 power section)

Scope of Supply
The scope of supply of the power section includes

6.2.4

1 x touch guard

1 connector X5 and X6 each

Technical Data

Ambient and Operating Conditions


General Information
Conditions for transport and storage: see chapter 4.2 Transport and Storage,
page 19.
Installation conditions: see chapter 4.3 Installation Conditions , page 20.
This chapter contains:

limit values for use in the scope of C-UL

applied standards (CE conformity, UL listing)

UL Data
Ambient and operating conditions - UL ratings
Description

Symbol

Unit

HMS01.1NW0020

pollution degree (UL)

HMS01.1NW0070

Use in a pollution degree 2 environment


ISCCR

rated input voltage, power (UL)3)


maximum input current (UL)4)

HMS01.1NW0054

Use copper 60/75 C only; class 1 or equivalent only

field wiring material (UL)1)

short circuit current rating, SCCR,


symmetrical amperes (UL)2)

HMS01.1NW0036

IL_cont

A rms

42000

254...750

14,0

24,5

40,0

49,0

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

105/315

Power Sections for Inverters - IndraDrive M

Description

Symbol

Unit

maximum output voltage (UL)

Uout

maximum output current (UL)

Iout_max

1)

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

35,0

42,4

500
12,1

21,3

find value for tightening torque in project planning manual, Electrical


Connection Points
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
HMS, HMD, HLB, HLC: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
at PDC_cont

2)

3)
4)

Fig.6-8:

HMS - Ambient and operating conditions - UL ratings

Ambient and operating conditions - UL ratings


Description

Symbol

Unit

HMS01.1N-W0110

HMS01.1N-W0210

Use copper 60/75 C only; class 1 or equivalent only

field wiring material (UL)1)


pollution degree (UL)
short circuit current rating, SCCR,
symmetrical amperes (UL)2)

HMS01.1N-W0150

Use in a pollution degree 2 environment


ISCCR

rated input voltage, power (UL)3)

A rms

42000

254...750

maximum input current (UL)4)

IL_cont

maximum output voltage (UL)

Uout

maximum output current (UL)

Iout_max

1)
2)

3)
4)

Fig.6-9:

80,0

115,0

167,0

500
68,5

100,0

145,0

find value for tightening torque in project planning manual, Electrical


Connection Points
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
HMS, HMD, HLB, HLC: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
at PDC_cont

HMS - Ambient and operating conditions - UL ratings

Information on Standards
Applied standards
Description
CE conformity regarding Low-Volt
age Directive
CE conformity regarding EMC
product standard

Symbol

Unit

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

EN61800-5-1
EN61800-3

high-voltage test, test rate

100% (EN61800-5-1)

high-voltage and insulation test,


test rate

100% (EN61800-5-1)

listing according to UL standard


(UL)

UL 508 C

HMS01.1NW0070

106/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Description

Symbol

Unit

HMS01.1NW0020

HMS01.1NW0036

UL files (UL)

HMS01.1NW0054

HMS01.1NW0070

E 134201

listing according to CSA standard


(UL)

Canadian National Standard(s) C22.2 No. 14-05

Fig.6-10:

HMS - Applied standards

Applied standards
Description

Symbol

Unit

HMS01.1N-W0110

CE conformity regarding Low-Volt


age Directive

HMS01.1N-W0150

HMS01.1N-W0210

EN61800-5-1

CE conformity regarding EMC


product standard

EN61800-3

high-voltage test, test rate

100% (EN61800-5-1)

high-voltage and insulation test,


test rate

100% (EN61800-5-1)

listing according to UL standard


(UL)

UL 508 C

UL files (UL)

E 134201

listing according to CSA standard


(UL)

Canadian National Standard(s) C22.2 No. 14-05

Fig.6-11:

HMS - Applied standards

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

107/315

Power Sections for Inverters - IndraDrive M

Mechanical System and Mounting


Dimensional Drawings
HMS01.1N-W0020 and HMS01.1NW0036

A)
B)
C)
D)

Fig.6-12:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!
dimensions for accessory HAS02.1 when motor cable run with 45
dimensions for accessory HAS02.1 when motor cable run horizontally

Dimensions HMS01.1N-W0020 and HMS01.1NW0036

108/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


HMS01.1N-W0054

A)
B)
C)
D)

Fig.6-13:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!
dimensions for accessory HAS02.1 when motor cable run with 45
dimensions for accessory HAS02.1 when motor cable run horizontally

Dimensions HMS01.1N-W0054

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

109/315

Power Sections for Inverters - IndraDrive M


HMS01.1N-W0070

A)
B)
C)
D)

Fig.6-14:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!
dimensions for accessory HAS02.1 when motor cable run with 45
dimensions for accessory HAS02.1 when motor cable run horizontally

Dimensions HMS01.1N-W0070

110/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


HMS01.1N-W0110

A)
B)
C)
D)
E)

Fig.6-15:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!
dimensions for accessory HAS02.1 when motor cable run horizontally
dimensions for accessory HAS02.1 when motor cable run with 45
dimensions for accessory HAS02.1 when motor cable run vertically

Dimensions HMS01.1N-W0110

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

111/315

Power Sections for Inverters - IndraDrive M


HMS01.1N-W0150

A)
B)
C)
D)
E)

Fig.6-16:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!
dimensions for accessory HAS02.1 when motor cable run horizontally
dimensions for accessory HAS02.1 when motor cable run with 45
dimensions for accessory HAS02.1 when motor cable run vertically

Dimensions HMS01.1N-W0150

112/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


HMS01.1N-W0210

A)
B)
C)
D)
E)

Fig.6-17:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!
dimensions for accessory HAS02.1 when motor cable run horizontally
dimensions for accessory HAS02.1 when motor cable run with 45
dimensions for accessory HAS02.1 when motor cable run vertically

Dimensions HMS01.1N-W0210

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

113/315

Power Sections for Inverters - IndraDrive M

Dimensions, Mass, Insulation


Data for mass, dimensions, sound pressure level, insulation
Description
Weight

Symbol

Unit

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

6,68

7,94

75

100

kg

(UL)1)

mm

440

Device depth (UL)2)

mm

262

(UL)3)

mm

insulation resistance at DC 500 V

Ris

MOhm

>50

capacitance against housing

CY

nF

2 x 68

average sound pressure level (ac


curacy class 2) at PDC_cont 4)

LP

dB (A)

tbd

Device height

Device width

1) 2) 3)
4)

5,27

50

housing dimension; see also related dimension sheet


according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent

Fig.6-18:

HMS - Data for mass, dimensions, sound pressure level, insulation

Data for mass, dimensions, sound pressure level, insulation


Description

Symbol

Unit

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

Weight

kg

11,06

12,74

16,44

Device height (UL)1)

mm

440

Device depth (UL)2)

mm

262

Device width (UL)3)

mm

insulation resistance at DC 500 V

Ris

MOhm

>50

capacitance against housing

CY

nF

2 x 100

average sound pressure level (ac


curacy class 2) at PDC_cont 4)

LP

dB (A)

1) 2) 3)
4)

125

150

200

76

tbd

housing dimension; see also related dimension sheet


according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent

Fig.6-19:

HMS - Data for mass, dimensions, sound pressure level, insulation

Power Dissipation, Cooling, Distances


Data for cooling and power dissipation
Description
ambient temperature range

derating at Ta_work < Ta < Ta_work_red


allowed mounting position

HMS01.1NW0036

HMS01.1NW0054

Unit

Ta_work

0...40

0...55

%/K

2,0

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)
2)

HMS01.1NW0020

Symbol

fTa

G1

HMS01.1NW0070

114/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Description

Symbol

Unit

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054
f

cooling type3)
volumetric capacity of forced cool
ing4)

m3/h

tbd

allowed switching frequencies5)

fs

kHz

4, 8, 12, 16

power dissipation at Iout_cont = 0 A;


fs = fs (min.)6)

HMS01.1NW0070

P
Diss_0A_fsmi

60

40

90

110

120

130

260

330

165,00

210,00

420,00

485,00

power dissipation at Iout_cont = 0 A;


fs = fs (max.)7)

Diss_0A_fsma

power dissipation at continuous


current Iout_cont and DC bus power
PDC_cont respectively (UL)8)

PDiss_cont

minimum distance on the top of the


device9)

dtop

mm

80

minimum distance on the bottom of


the device10)

dbot

mm

100

temperature rise with minimum dis


tances dbot; dtop; PBD

40

50

40

50

temperature rise with minimum dis


tances dbot; dtop; cooling air current
fails; PBD

40

50

40

50

1)
2)
3)
4)
5)

observe derating
data to be derated: PDC_cont; PBD; Iout_cont
n: natural convection; f: forced cooling
HLR: see following note regarding cooling
also depending on firmware and control section; see parameter de
scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS); find interim values by interpolation to P_Diss_cont
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS)
see fig. "Air intake and air outlet at drive controller"

6) 7)
8)
9) 10)

Fig.6-20:

HMS - Data for cooling and power dissipation

Data for cooling and power dissipation


Description
ambient temperature range

Symbol

Unit

Ta_work

0...40

0...55

%/K

2,0

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)
derating at Ta_work < Ta < Ta_work_red
2)

allowed mounting position


cooling type3)

fTa

HMS01.1N-W0110

HMS01.1N-W0150

G1
f

HMS01.1N-W0210

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

115/315

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

HMS01.1N-W0110

volumetric capacity of forced cool


ing4)

m3/h

165,00

allowed switching frequencies5)

fs

kHz

HMS01.1N-W0150

HMS01.1N-W0210
tbd

4, 8, 12, 16

power dissipation at Iout_cont = 0 A;


fs = fs (min.)6)

Diss_0A_fsmi

power dissipation at Iout_cont = 0 A;


fs = fs (max.)7)

Diss_0A_fsma

power dissipation at continuous


current Iout_cont and DC bus power
PDC_cont respectively (UL)8)

PDiss_cont

minimum distance on the top of the


device9)

dtop

mm

80

minimum distance on the bottom of


the device10)

dbot

mm

100

temperature rise with minimum dis


tances dbot; dtop; PBD

35

45

temperature rise with minimum dis


tances dbot; dtop; cooling air current
fails; PBD

35

45

P
tbd

1)
2)
3)
4)
5)
6) 7)
8)
9) 10)

Fig.6-21:
Power Dissipation vs. Output Cur
rent

tbd

640,00

965,00

1570,00

observe derating
data to be derated: PDC_cont; PBD; Iout_cont
n: natural convection; f: forced cooling
HLR: see following note regarding cooling
also depending on firmware and control section; see parameter de
scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS); find interim values by interpolation to P_Diss_cont
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS)
see fig. "Air intake and air outlet at drive controller"

HMS - Data for cooling and power dissipation

The figure below illustrates the connection between power dissipation and out
put current, depending on the switching frequency fs which was set at the drive
controller. See also Parameter Description "P-0-0001, Switching frequency of
the power output stage".
In addition, take the power at the braking resistor and the power
consumption of the control section into account. Both powers are
not contained in the figure.

116/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Fig.6-22:

Power dissipation vs. output current

Distances
Property damage due to temperatures higher than 105 C!
Comply with indicated minimum distances!

CAUTION

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

117/315

Power Sections for Inverters - IndraDrive M

A
B
C
dtop
dbot

air intake
air outlet
mounting surface in control cabinet
distance top
distance bottom

Fig.6-23:

Air intake and air outlet at drive controller

Basic Data Power Section HMS01


General Information
This section contains

data for control voltage supply

data of DC bus

data of inverter
The order of the data tables below follows the energy flow in the
drive controller - from mains connection to motor output.

Control Voltage
Data for control voltage supply
Description

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

Symbol

Unit

rated control voltage input (UL)1)

UN3

24 20 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length < 50 m2)

UN3

24 5 %

HMS01.1NW0070

118/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Description

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

Symbol

Unit

UN3

26 5 %

maximum allowed voltage for


1 ms5)

UN3_max

33 (1ms)

inrush current at 24V supply

IEIN3

tbd

pulse width of IEIN3

tEIN3Lade

ms

tbd

input capacitance

CN3

mF

tbd

rated power consumption control


voltage input without holding brake,
without control section at
UN3 = DC 24 V (UL)6)

PN3

internal control voltage (optional)7)

Ucontr_int

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length > 50 m3)
maximum ripple content4)

1) 2) 3)
4)
5)
6)
7)

10

15

HMS01.1NW0070

10

16

observe supply voltage for motor holding brakes


absolute voltage values must be within UN3
see following note regarding overvoltage
find value for control section in project planning manual
value only with HCS02, HCS03: Types with order code -***V

Fig.6-24:

HMS - Data for control voltage supply

Data for control voltage supply


Description

Symbol

Unit

rated control voltage input (UL)1)

UN3

24 20 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length < 50 m2)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length > 50 m3)

UN3

26 5 %

maximum allowed voltage for


1 ms5)

UN3_max

33 (1ms)

inrush current at 24V supply

IEIN3

8,50

tbd

pulse width of IEIN3

tEIN3Lade

ms

tbd

input capacitance

CN3

mF

1,00

tbd

maximum ripple content4)

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

119/315

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

rated power consumption control


voltage input without holding brake,
without control section at
UN3 = DC 24 V (UL)6)

PN3

34

23

75

internal control voltage (optional)7)

Ucontr_int

1) 2) 3)
4)
5)
6)
7)

observe supply voltage for motor holding brakes


absolute voltage values must be within UN3
see following note regarding overvoltage
find value for control section in project planning manual
value only with HCS02, HCS03: Types with order code -***V

Fig.6-25:

HMS - Data for control voltage supply

Overvoltage of more than 33 V has to be discharged by means of


the appropriate electrical equipment of the machine or installation.
This includes:

24V power supply units that reduce incoming overvoltage to


the allowed value.

Overvoltage limiters at the control cabinet input that limit ex


isting overvoltage to the allowed value. This, too, applies to
long 24V lines that have been run in parallel to power cables
and mains cables and can absorb overvoltage by inductive or
capacitive coupling.

DC Bus
Data of power section - DC bus
Description

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

Symbol

Unit

DC bus voltage range1)

UDC

254...750

capacitance in DC bus

CDC

mF

maximum discharge time from


UR_DC_On to DC 50 V2)

tentl_ZK

storable energy of internal DC bus


capacitance3)

WDC

Ws

DC resistance in DC bus (L+ to L-)


at UDC = 750 V

RDC

ohm

continuous load kVA at cos=1

PDC

kW

120,00

maximum possible load kVA at


cos=1

PDC

kW

180,00

900

monitoring value maximum DC bus


voltage, switch-off threshold4)

U
DC_limit_max

HMS01.1NW0070

120/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Description
monitoring value minimum DC bus
voltage, undervoltage threshold5)

Symbol
U
DC_limit_min

efficiency for nominal data

Unit

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

254

0,93

1)
2)
3)
4)
5)

depending on mains input voltage ULN


without other device on DC bus
at ULN_nenn to UR_DC_On
HMV: see also troubleshooting guide for E8025, F2817
HMV: see also troubleshooting guide for E2026, F2026; HCS: Depend
ing on parameter setting, see parameter description "P00114, Under
voltage threshold"

Fig.6-26:

HMS - Data of power section - DC bus

Data of power section - DC bus


Description

Symbol

Unit

DC bus voltage range1)

UDC

254...750

capacitance in DC bus

CDC

mF

maximum discharge time from


UR_DC_On to DC 50 V2)

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

tentl_ZK

storable energy of internal DC bus


capacitance3)

WDC

Ws

DC resistance in DC bus (L+ to L-)


at UDC = 750 V

RDC

ohm

continuous load kVA at cos=1

PDC

kW

120,00

maximum possible load kVA at


cos=1

PDC

kW

180,00

900

254

monitoring value maximum DC bus


voltage, switch-off threshold4)

DC_limit_max

monitoring value minimum DC bus


voltage, undervoltage threshold5)

DC_limit_min

efficiency for nominal data

1)
2)
3)
4)
5)

Fig.6-27:

0,93
depending on mains input voltage ULN
without other device on DC bus
at ULN_nenn to UR_DC_On
HMV: see also troubleshooting guide for E8025, F2817
HMV: see also troubleshooting guide for E2026, F2026; HCS: Depend
ing on parameter setting, see parameter description "P00114, Under
voltage threshold"

HMS - Data of power section - DC bus

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

121/315

Power Sections for Inverters - IndraDrive M

Inverter
Data of power section - Inverter
Description

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

Symbol

Unit

fs

kHz

4, 8, 12, 16

output voltage, fundamental wave


with open-loop operation

Uout_eff

~ UDC x 0,71

output voltage, fundamental wave


with closed-loop operation

Uout_eff

~ UDC x 0,71

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-phase (1090%)2)

du/dt

kV/s

5,00

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-ground (1090%)3)

du/dt

kV/s

5,00

output frequency range at fs = 2 kHz

fout_2k

Hz

output frequency range at fs = 4 kHz

fout_4k

Hz

0...400

output frequency range at fs = 8 kHz

fout_8k

Hz

0...800

output frequency range at


fs = 12 kHz

fout_12k

Hz

0...1200

output frequency range at


fs = 16 kHz

fout_16k

Hz

0...1600

maximum output current at


fs = 2 kHz

Iout_max2

maximum output current at


fs = 4 kHz

Iout_max4

20,0

36,0

54,0

70,7

maximum output current at


fs = 8 kHz

Iout_max8

20,0

36,0

54,0

70,7

maximum output current at


fs = 12 kHz

Iout_max12

16,0

31,0

45,0

65,0

maximum output current at


fs = 16 kHz

Iout_max16

11,0

24,0

35,0

51,0

allowed continuous output current


at fs = 2 kHz

Iout_cont2

allowed continuous output current


at fs = 4 kHz

Iout_cont4

12,1

21,3

35,0

42,4

allowed continuous output current


at fs = 8 kHz

Iout_cont8

8,3

15,0

20,0

24,1

allowed continuous output current


at fs = 12 kHz4)

Iout_cont12

5,0

9,5

12,0

14,4

allowed continuous output current


at fs = 16 kHz5)

Iout_cont16

2,7

6,0

7,5

9,3

allowed switching frequencies1)

122/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Description

Symbol

allowed continuous output current


at fs = 2 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 4 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 8 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 12 kHz; output frequency
fout < fout_still 6)

Unit

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

I
A

I
A

8,1

14,2

23,4

28,3

5,5

10,0

13,4

16,1

3,3

6,4

8,2

9,6

1,8

4,0

5,1

6,2

I
8

I
out_cont0Hz_
12

allowed continuous output current


at fs = 16 kHz; output frequency
fout < fout_still 7)

out_cont0Hz_

output frequency threshold to de


tect motor standstill8)

fout_still

I
16

Hz

2...4

assigned output filters at nom. da


ta; fs = 4 kHz

1)

also depending on firmware and control section; see parameter de


scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
guide value, see following note
see parameter description "P00556, Config word of axis controller",
load-depending reduction of PWM frequency fs
see following note regarding reduction output current

2) 3)
4) 5) 6) 7)
8)

Fig.6-28:

HMS - Data of power section - Inverter

Data of power section - Inverter


Description

Symbol

Unit

fs

kHz

4, 8, 12, 16

output voltage, fundamental wave


with open-loop operation

Uout_eff

~ UDC x 0,71

output voltage, fundamental wave


with closed-loop operation

Uout_eff

~ UDC x 0,71

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-phase (1090%)2)

du/dt

kV/s

5,00

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-ground (1090%)3)

du/dt

kV/s

5,00

output frequency range at fs = 2 kHz

fout_2k

Hz

output frequency range at fs = 4 kHz

fout_4k

Hz

0...400

output frequency range at fs = 8 kHz

fout_8k

Hz

0...800

allowed switching frequencies1)

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

123/315

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

output frequency range at


fs = 12 kHz

fout_12k

Hz

0...1200

output frequency range at


fs = 16 kHz

fout_16k

Hz

0...1600

maximum output current at


fs = 2 kHz

Iout_max2

maximum output current at


fs = 4 kHz

Iout_max4

110,0

150,0

210,0

maximum output current at


fs = 8 kHz

Iout_max8

110,0

150,0

210,0

maximum output current at


fs = 12 kHz

Iout_max12

75,0

136,0

190,0

maximum output current at


fs = 16 kHz

Iout_max16

60,0

106,0

155,0

allowed continuous output current


at fs = 2 kHz

Iout_cont2

allowed continuous output current


at fs = 4 kHz

Iout_cont4

68,5

99,7

150,7

allowed continuous output current


at fs = 8 kHz

Iout_cont8

43,5

67,5

101,7

allowed continuous output current


at fs = 12 kHz4)

Iout_cont12

32,0

48,4

72,6

allowed continuous output current


at fs = 16 kHz5)

Iout_cont16

25,5

36,8

54,2

allowed continuous output current


at fs = 2 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 4 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 8 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 12 kHz; output frequency
fout < fout_still 6)

out_cont0Hz_

allowed continuous output current


at fs = 16 kHz; output frequency
fout < fout_still 7)

out_cont0Hz_

I
A

I
A

42,2

57,0

86,1

24,9

38,6

58,2

18,3

27,7

41,5

14,7

21,1

31,0

I
8

I
12

I
16

124/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description
output frequency threshold to de
tect motor standstill8)

Symbol

Unit

fout_still

Hz

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

2...4

assigned output filters at nom. da


ta; fs = 4 kHz

1)

also depending on firmware and control section; see parameter de


scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
guide value, see following note
see parameter description "P00556, Config word of axis controller",
load-depending reduction of PWM frequency fs
see following note regarding reduction output current

2) 3)
4) 5) 6) 7)
8)

Fig.6-29:

HMS - Data of power section - Inverter

Observe that the load is almost independent of the power section


used.
Especially when using standard motors , make sure that they com
ply with the occurring voltage load.
Observe the information contained in the chapter Third-Party Mo
tors at IndraDrive Controllers in the Project Planning Manual of the
drive system.
Depending on the electric output frequency, the output current is
reduced for thermal protection of the power section.
The output current is reduced, when the electric output frequency
has fallen below the threshold to detect motor standstill.

Exemplary Data for Applications


General Information
This section contains

examples of allowed current profiles

examples of allowed performance profiles

data for selecting standard motors

Current Profiles
Examples of allowed current profiles
Description

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

34,71

54,00

66,87

13,88

21,60

26,75

Symbol

Unit

Iout_peak1_2

base load current at Iout_peak_1;


Iout_base1_2
fs = 2 kHz; t = 0,4 s; T = 4 s; K = 2,5

maximum output current at


Iout_base_1; fs = 4 kHz; t = 0,4 s;
T = 4 s; K = 2,52)

Iout_peak1_4

19,05

base load current at Iout_peak_1;


Iout_base1_4
fs = 4 kHz; t = 0,4 s; T = 4 s; K = 2,5

7,62

maximum output current at


Iout_base_1; fs = 2 kHz; t = 0,4 s;
T = 4 s; K = 2,51)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

125/315

Power Sections for Inverters - IndraDrive M

Symbol

Unit

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

Iout_peak1_8

13,22

24,83

34,39

38,76

base load current at Iout_peak_1;


Iout_base1_8
fs = 8 kHz; t = 0,4 s; T = 4 s; K = 2,5

5,29

9,93

13,76

15,50

maximum output current at


Iout_base_1; fs = 12 kHz; t = 0,4 s;
T = 4 s; K = 2,54)

8,06

15,90

21,07

23,40

3,22

6,36

8,43

9,36

4,40

10,10

13,21

15,18

1,76

4,04

5,28

6,07

Description
maximum output current at
Iout_base_1; fs = 8 kHz; t = 0,4 s;
T = 4 s; K = 2,53)

base load current at Iout_peak_1;


fs = 12 kHz; t = 0,4 s; T = 4 s; K = 2,5
maximum output current at
Iout_base_1; fs = 16 kHz; t = 0,4 s;
T = 4 s; K = 2,55)
base load current at Iout_peak_1;
fs = 16 kHz; t = 0,4 s; T = 4 s; K = 2,5

I
out_peak1_12

I
out_base1_12

I
out_peak1_16

I
out_base1_16

maximum output current at


Iout_base_3; fs = 2 kHz; t = 2 s; T = 20 s; Iout_peak3_2
K = 2,06)

base load current at Iout_peak_3;


Iout_base3_2
fs = 2 kHz; t = 2 s; T = 20 s; K = 2,0

maximum output current at


Iout_base_3; fs = 4 kHz; t = 2 s; T = 20 s; Iout_peak3_4
K = 2,07)

17,28

31,32

52,93

60,94

base load current at Iout_peak_3;


Iout_base3_4
fs = 4 kHz; t = 2 s; T = 20 s; K = 2,0

8,64

15,66

26,46

30,47

maximum output current at


Iout_base_3; fs = 8 kHz; t = 2 s; T = 20 s; Iout_peak3_8
K = 2,08)

11,93

22,27

30,67

35,04

base load current at Iout_peak_3;


Iout_base3_8
fs = 8 kHz; t = 2 s; T = 20 s; K = 2,0

5,96

11,14

15,33

17,52

maximum output current at


Iout_base_3; fs = 12 kHz; t = 2 s;
T = 20 s; K = 2,09)

7,24

14,19

18,73

21,06

3,62

7,09

9,36

10,53

3,94

8,98

11,72

13,63

1,97

4,49

5,86

6,81

base load current at Iout_peak_3;


fs = 12 kHz; t = 2 s; T = 20 s; K = 2,0
maximum output current at
Iout_base_3; fs = 16 kHz; t = 2 s;
T = 20 s; K = 2,010)
base load current at Iout_peak_3;
fs = 16 kHz; t = 2 s; T = 20 s; K = 2,0

I
out_peak3_12

I
out_base3_12

I
out_peak3_16

I
out_base3_16

base load current at Iout_peak_4;


Iout_base4_2
fs = 2 kHz; t = 60 s; T = 5 min; K = 1,5

126/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


HMS01.1NW0054

HMS01.1NW0070

22,45

40,45

45,67

8,40

14,97

26,97

30,45

8,64

15,85

23,26

26,02

base load current at Iout_peak_4;


Iout_base4_8
fs = 8 kHz; t = 60 s; T = 5 min; K = 1,5

5,76

10,57

15,51

17,35

maximum output current at


Iout_base_4; fs = 12 kHz; t = 60 s;
T = 5 min; K = 1,514)

5,22

10,04

14,16

15,56

3,48

6,69

9,44

10,37

2,83

6,33

8,85

10,05

1,89

4,22

5,90

6,70

Description

HMS01.1NW0020

Symbol

Unit

maximum output current at


Iout_base_4; fs = 2 kHz; t = 60 s;
T = 5 min; K = 1,511)

Iout_peak4_2

maximum output current at


Iout_base_4; fs = 4 kHz; t = 60 s;
T = 5 min; K = 1,512)

Iout_peak4_4

12,60

base load current at Iout_peak_4;


Iout_base4_4
fs = 4 kHz; t = 60 s; T = 5 min; K = 1,5

maximum output current at


Iout_base_4; fs = 8 kHz; t = 60 s;
T = 5 min; K = 1,513)

Iout_peak4_8

base load current at Iout_peak_4;


fs = 12 kHz; t = 60 s; T = 5 min;
K = 1,5
maximum output current at
Iout_base_4; fs = 16 kHz; t = 60 s;
T = 5 min; K = 1,515)
base load current at Iout_peak_4;
fs = 16 kHz; t = 60 s; T = 5 min;
K = 1,5

I
out_peak4_12

I
out_base4_12

I
out_peak4_16

I
out_base4_16

HMS01.1NW0036
-

maximum output current at


Iout_base_5; fs = 2 kHz; t = 60 s;
T = 10 min; K = 1,116)

Iout_peak5_2

base load current at Iout_peak_5;


fs = 2 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_2

maximum output current at


Iout_base_5; fs = 4 kHz; t = 60 s;
T = 10 min; K = 1,117)

Iout_peak5_4

12,26

21,67

36,47

43,32

base load current at Iout_peak_5;


fs = 4 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_4

11,15

19,70

33,16

39,38

maximum output current at


Iout_base_5; fs = 8 kHz; t = 60 s;
T = 10 min; K = 1,118)

Iout_peak5_8

8,39

15,28

20,91

24,63

base load current at Iout_peak_5;


fs = 8 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_8

7,63

13,89

19,01

22,39

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

127/315

Power Sections for Inverters - IndraDrive M

Description
maximum output current at
Iout_base_5; fs = 12 kHz; t = 60 s;
T = 10 min; K = 1,119)
base load current at Iout_peak_5;
fs = 12 kHz; t = 60 s; T = 10 min;
K = 1,1
maximum output current at
Iout_base_5; fs = 16 kHz; t = 60 s;
T = 10 min; K = 1,120)
base load current at Iout_peak_5;
fs = 16 kHz; t = 60 s; T = 10 min;
K = 1,1

Symbol
I
out_peak5_12

I
out_base5_12

I
out_peak5_16

I
out_base5_16

Unit

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

5,07

9,67

12,71

14,71

4,61

8,79

11,56

13,37

2,75

6,09

7,94

9,50

2,50

5,54

7,22

8,63

1) 2) 3) 4) 5) 6) see definition profile UEL_I_e


7) 8) 9) 10)
11) 12) 13)
14) 15) 16)
17) 18) 19)
20)

Fig.6-30:

HMS - Examples of allowed current profiles

Examples of allowed current profiles


Description

Symbol

Unit

Iout_peak1_2

base load current at Iout_peak_1;


Iout_base1_2
fs = 2 kHz; t = 0,4 s; T = 4 s; K = 2,5

maximum output current at


Iout_base_1; fs = 4 kHz; t = 0,4 s;
T = 4 s; K = 2,52)

Iout_peak1_4

106,40

150,00

210,00

base load current at Iout_peak_1;


Iout_base1_4
fs = 4 kHz; t = 0,4 s; T = 4 s; K = 2,5

42,56

60,00

84,00

maximum output current at


Iout_base_1; fs = 8 kHz; t = 0,4 s;
T = 4 s; K = 2,53)

Iout_peak1_8

67,91

107,09

156,29

base load current at Iout_peak_1;


Iout_base1_8
fs = 8 kHz; t = 0,4 s; T = 4 s; K = 2,5

27,16

42,84

62,52

maximum output current at


Iout_base_1; fs = 12 kHz; t = 0,4 s;
T = 4 s; K = 2,54)

50,36

77,35

112,47

20,14

30,94

44,99

40,62

58,83

84,38

maximum output current at


Iout_base_1; fs = 2 kHz; t = 0,4 s;
T = 4 s; K = 2,51)

base load current at Iout_peak_1;


fs = 12 kHz; t = 0,4 s; T = 4 s; K = 2,5
maximum output current at
Iout_base_1; fs = 16 kHz; t = 0,4 s;
T = 4 s; K = 2,55)

I
out_peak1_12

I
out_base1_12

I
out_peak1_16

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

128/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description
base load current at Iout_peak_1;
fs = 16 kHz; t = 0,4 s; T = 4 s; K = 2,5

Symbol
I
out_base1_16

Unit

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

16,25

23,53

33,75

maximum output current at


Iout_base_3; fs = 2 kHz; t = 2 s; T = 20 s; Iout_peak3_2
K = 2,06)

base load current at Iout_peak_3;


Iout_base3_2
fs = 2 kHz; t = 2 s; T = 20 s; K = 2,0

maximum output current at


Iout_base_3; fs = 4 kHz; t = 2 s; T = 20 s; Iout_peak3_4
K = 2,07)

95,87

140,83

208,94

base load current at Iout_peak_3;


Iout_base3_4
fs = 4 kHz; t = 2 s; T = 20 s; K = 2,0

47,93

70,41

104,47

maximum output current at


Iout_base_3; fs = 8 kHz; t = 2 s; T = 20 s; Iout_peak3_8
K = 2,08)

60,73

96,70

142,91

base load current at Iout_peak_3;


Iout_base3_8
fs = 8 kHz; t = 2 s; T = 20 s; K = 2,0

30,36

48,35

71,45

maximum output current at


Iout_base_3; fs = 12 kHz; t = 2 s;
T = 20 s; K = 2,09)

44,90

69,65

102,46

22,45

34,83

51,23

36,17

52,97

76,75

18,09

26,49

38,37

base load current at Iout_peak_3;


fs = 12 kHz; t = 2 s; T = 20 s; K = 2,0
maximum output current at
Iout_base_3; fs = 16 kHz; t = 2 s;
T = 20 s; K = 2,010)
base load current at Iout_peak_3;
fs = 16 kHz; t = 2 s; T = 20 s; K = 2,0

I
out_peak3_12

I
out_base3_12

I
out_peak3_16

I
out_base3_16

base load current at Iout_peak_4;


Iout_base4_2
fs = 2 kHz; t = 60 s; T = 5 min; K = 1,5

maximum output current at


Iout_base_4; fs = 2 kHz; t = 60 s;
T = 5 min; K = 1,511)

Iout_peak4_2

maximum output current at


Iout_base_4; fs = 4 kHz; t = 60 s;
T = 5 min; K = 1,512)

Iout_peak4_4

70,02

106,73

162,71

base load current at Iout_peak_4;


Iout_base4_4
fs = 4 kHz; t = 60 s; T = 5 min; K = 1,5

46,68

71,16

108,47

maximum output current at


Iout_base_4; fs = 8 kHz; t = 60 s;
T = 5 min; K = 1,513)

Iout_peak4_8

43,90

72,42

110,19

base load current at Iout_peak_4;


Iout_base4_8
fs = 8 kHz; t = 60 s; T = 5 min; K = 1,5

29,27

48,28

73,46

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

129/315

Power Sections for Inverters - IndraDrive M


Description
maximum output current at
Iout_base_4; fs = 12 kHz; t = 60 s;
T = 5 min; K = 1,514)
base load current at Iout_peak_4;
fs = 12 kHz; t = 60 s; T = 5 min;
K = 1,5
maximum output current at
Iout_base_4; fs = 16 kHz; t = 60 s;
T = 5 min; K = 1,515)
base load current at Iout_peak_4;
fs = 16 kHz; t = 60 s; T = 5 min;
K = 1,5

Symbol
I
out_peak4_12

I
out_base4_12

I
out_peak4_16

I
out_base4_16

Unit

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

32,34

52,00

78,67

21,56

34,67

52,45

26,01

39,54

58,83

17,34

26,36

39,22

maximum output current at


Iout_base_5; fs = 2 kHz; t = 60 s;
T = 10 min; K = 1,116)

Iout_peak5_2

base load current at Iout_peak_5;


fs = 2 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_2

maximum output current at


Iout_base_5; fs = 4 kHz; t = 60 s;
T = 10 min; K = 1,117)

Iout_peak5_4

69,32

101,61

153,95

base load current at Iout_peak_5;


fs = 4 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_4

63,02

92,38

139,95

maximum output current at


Iout_base_5; fs = 8 kHz; t = 60 s;
T = 10 min; K = 1,118)

Iout_peak5_8

43,73

68,78

104,01

base load current at Iout_peak_5;


fs = 8 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_8

39,75

62,53

94,56

32,21

49,37

74,19

29,28

44,88

67,45

maximum output current at


Iout_base_5; fs = 12 kHz; t = 60 s;
T = 10 min; K = 1,119)
base load current at Iout_peak_5;
fs = 12 kHz; t = 60 s; T = 10 min;
K = 1,1

I
out_peak5_12

I
out_base5_12

130/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description
maximum output current at
Iout_base_5; fs = 16 kHz; t = 60 s;
T = 10 min; K = 1,120)
base load current at Iout_peak_5;
fs = 16 kHz; t = 60 s; T = 10 min;
K = 1,1

Symbol
I
out_peak5_16

I
out_base5_16

Unit

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

25,90

37,54

55,46

23,55

34,13

50,42

1) 2) 3) 4) 5) 6) see definition profile UEL_I_e


7) 8) 9) 10)
11) 12) 13)
14) 15) 16)
17) 18) 19)
20)

Fig.6-31:
Current Profile UEL_I_e

HMS - Examples of allowed current profiles

The following current profiles have been defined for converters and inverters.
Profile
Current profile UEL_I_e

Explanation

The characteris
tic data of the
profile are used
to select convert
ers and inverters
for operation with
standard motors
and servo drives.

Fig.6-32:

Definition of current profiles

Operation With Standard Motors


General Information
Selecting Standard Motors

The tables below contain the nominal power Pnenn of standard motors which
can be operated at the respective drive controller. The data are subject to the
following conditions:

motor design:
4-pole standard motor (2 pole pairs) with rated voltage 3AC400V, 50Hz at
mains voltage ULN 3AC400V or
4-pole standard motor (2 pole pairs) with rated voltage 3AC460V, 60Hz at
mains voltage ULN 3AC460V

assigned mains choke is used

operation at minimum switching frequency fs= fs (min.)

rotary field at output with fout>fout_still

ambient temperature TaTa_work

overload ratio K=PDC_peak/PDC_base according to performance profile


UEL_P_e

type of mains connection: individual supply

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

131/315

Power Sections for Inverters - IndraDrive M


When choosing standard motors for HMS/HMD, additionally select
an appropriate HMV supply unit. Observe the performance data
PDC_peak and PDC_base in the performance profile UEL_P_e of the
supply unit.

Operating Standard Motors at 3 AC 400 V


Selection of standard motors 3 AC 400V - Exemplary profiles
Symbol

Unit

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

nominal power standard motor


3 AC 400 V; 50 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

5,50

11,00

18,50

22,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

4,00

7,50

15,00

18,50

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

3,00

7,50

11,00

15,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

3,00

7,50

11,00

15,00

Description

1) 2) 3) 4)

see definition profile UEL_P_e

Fig.6-33:

HMS - Selection of standard motors 3 AC 400V - Exemplary profiles

Selection of standard motors 3 AC 400V - Exemplary profiles


Description

Symbol

Unit

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

nominal power standard motor


3 AC 400 V; 50 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

tbd

55,00

75,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

tbd

45,00

75,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

tbd

37,00

55,00

nominal power standard motor


3 AC 400 V; 50 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

tbd

37,00

55,00

1) 2) 3) 4)

Fig.6-34:

see definition profile UEL_P_e

HMS - Selection of standard motors 3 AC 400V - Exemplary profiles

132/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Operating Standard Motors at 3 AC 460 V


Selection of standard motors 3 AC 460V - Exemplary profiles
Symbol

Unit

HMS01.1NW0020

HMS01.1NW0036

HMS01.1NW0054

HMS01.1NW0070

nominal power standard motor


3AC460V; 60 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

5,50

11,00

18,40

22,10

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

5,50

11,00

18,40

22,10

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

3,70

7,40

14,70

nominal power standard motor


3AC460V; 60 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

3,70

7,40

14,70

Description

1) 2) 3) 4)

see definition profile UEL_P_e; 1 kW ~ 1,36 hp

Fig.6-35:

HMS - Selection of standard motors 3 AC 460V - Exemplary profiles

Selection of standard motors 3 AC 460V - Exemplary profiles


Description

Symbol

Unit

HMS01.1N-W0110

HMS01.1N-W0150

HMS01.1N-W0210

nominal power standard motor


3AC460V; 60 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

36,80

55,20

91,90

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

36,80

55,20

73,60

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

22,10

36,80

55,20

nominal power standard motor


3AC460V; 60 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

22,10

36,80

55,20

1) 2) 3) 4)

Fig.6-36:
Performance Profile UEL_P_e

see definition profile UEL_P_e; 1 kW ~ 1,36 hp

HMS - Selection of standard motors 3 AC 460V - Exemplary profiles

The following performance profiles have been defined for converters and in
verters.
Observe the allowed performance data PDC_peak and PDC_base in the
corresponding performance profile of the supply unit or converter.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

133/315

Power Sections for Inverters - IndraDrive M

Profile
Performance profile UEL_P_e

Explanation

Characteristic of
the selection of
standard motors
and servo drives.

Fig.6-37:

Definition of performance profiles, infeeding supply units and converters

134/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

6.2.5

Connections and Interfaces

Overview
Overall Connection Diagram

Fig.6-38:

Connection diagram HMS01.1-Wxxxx

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

135/315

Power Sections for Inverters - IndraDrive M

Arrangement of the Connection Points


Connection Points at HMS01.1N-W0020 and HMS01.1N-W0036
Connections at Power Section (Front)

1)
2)
3)
X1 in, X1 out

Fig.6-39:

control voltage
DC bus
equipment grounding conductor
module bus

Connections at power section (front) HMS01.1N-W0020 and


HMS01.1N-W0036

136/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Connections at Power Section (Bottom)

X5
X6
XS2

Fig.6-40:

motor connection
motor temperature monitoring and motor holding brake
shield connection (motor power cable)

Connections at power section (bottom) HMS01.1N-W0020, -W0036

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

137/315

Power Sections for Inverters - IndraDrive M

Connection Points at HMS01.1N-W0054 and HMS01.1N-W0070


Connections at Power Section (Front)

1)
2)
3)
X1 in, X1 out

Fig.6-41:

control voltage
DC bus
equipment grounding conductor
module bus

Connections at power section (front) HMS01.1N-W0054 and W0070

138/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Connections at Power Section (Bottom)

X5
X6
XS2

Fig.6-42:

motor connection
motor temperature monitoring and motor holding brake
shield connection (motor power cable)

Connections at power section (bottom) HMS01.1N-W0054 and W0070

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

139/315

Power Sections for Inverters - IndraDrive M

Connection Points at HMS01.1N-W0110, HMS01.1N-W0150,


HMS01.1N-W0210 and HMS01.1N-W0350 (Preliminary)
Connections at Power Section (Front)

1)
2)
3)
4)
5)
X1 in, X1 out

Fig.6-43:

control voltage
DC bus
equipment grounding conductor
plate for shield connection of motor cable (optional)
motor connection
module bus

Connections at power section (front) HMS01.1N-W0110, HMS01.1NW0150 and HMS01.1N-W0210

140/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Connections at Power Section (Bottom)

X6
XS2

Fig.6-44:

motor temperature monitoring and motor holding brake


shield connection (motor power cable)

Connections at power section (bottom) HMS01.1N-W0110, HMS01.1NW0150 and HMS01.1N-W0210

Description of the Connection Points


The connection points are described in detail in chapter 8 Functions and Elec
trical Connection Points , page 255.
Touch Guard

The touch guard is described in detail in chapter 9 Touch Guard at Devices ,


page 299.

6.3

HMS02 Power Sections

6.3.1

Brief Description, Usage and Structure


Brief Description
Usage

The HMS02 inverters are part of the Rexroth IndraDrive M product range and
are used to operate single axes.
The different types are used as follows:
Type

Usage

HMS02.1E-Wxxxx-NNNN

single-axis device

Operation of a three-phase a.c. mo


tor (asynchronous or synchronous
motor).

Fig.6-45:

Usage of HMS02

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

141/315

Power Sections for Inverters - IndraDrive M


Structure, Block Diagrams

1
2

power section
control section

1)
2)

inverter stage with output to motor


DC bus connection

Fig.6-46:

Fig.6-47:

Basic structure of the drive controller

HMS02 - block diagram

142/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

6.3.2

Type Code and Identification

Type Code
The following figure illustrates the basic structure of the type code.
Our sales representative will help you with the current status of
available versions.

Fig.6-48:

Type code HMS02

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

143/315

Power Sections for Inverters - IndraDrive M

Identification
Type Plate Arrangement

HMS02.1N-W0028

1
2
3
Type Plate

power section type plate


control section type plate
firmware type plate

Fig.6-49:

Type plates at the drive controller

1
2
3
4
5
6
7

device type
part number
serial number
bar code
country of manufacture
production week, 04W12 meaning year 2004, week 12
hardware index

Fig.6-50:

6.3.3

HMS02.1N-W0054

Type plate - power section (example of an HCS02 power section)

Scope of Supply
The scope of supply of the power section includes

144/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

6.3.4

1 x touch guard

1 connector X5 and X6 each

Technical Data

Ambient and Operating Conditions


General Information
Conditions for transport and storage: see chapter 4.2 Transport and Storage,
page 19.
Installation conditions: see chapter 4.3 Installation Conditions , page 20.
This chapter contains:

limit values for use in the scope of C-UL

applied standards (CE conformity, UL listing)

UL Data
Ambient and operating conditions - UL ratings
Description

Symbol

Unit

HMS02.1N-W0028

Use copper 60/75 C only; class 1 or equivalent only

field wiring material (UL)1)


pollution degree (UL)
short circuit current rating, SCCR,
symmetrical amperes (UL)2)

HMS02.1N-W0054

Use in a pollution degree 2 environment


ISCCR

rated input voltage, power (UL)3)

A rms

42000

254...750

maximum input current (UL)4)

IL_cont

maximum output voltage (UL)

Uout

maximum output current (UL)

Iout_max

1)
2)

3)
4)

Fig.6-51:

18,4

30,7
500

15,0

25,0

find value for tightening torque in project planning manual, Electrical


Connection Points
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
HMS, HMD, HLB, HLC: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
at PDC_cont

HMS - Ambient and operating conditions - UL ratings

Information on Standards
Applied standards
Description
CE conformity regarding Low-Volt
age Directive
CE conformity regarding EMC
product standard

Symbol

Unit

HMS02.1N-W0028

HMS02.1N-W0054
EN61800-5-1
EN61800-3

high-voltage test, test rate

100% (EN61800-5-1)

high-voltage and insulation test,


test rate

100% (EN61800-5-1)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

145/315

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

HMS02.1N-W0028

HMS02.1N-W0054

listing according to UL standard


(UL)

UL 508 C

UL files (UL)

E 134201

listing according to CSA standard


(UL)

Canadian National Standard(s) C22.2 No. 14-05

Fig.6-52:

HMS - Applied standards

146/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Mechanical System and Mounting


Dimensional Drawings
Dimensions HMS02.1N-W0028

A)
B)

Fig.6-53:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!

Dimensions HMS02.1N-W0028

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

147/315

Power Sections for Inverters - IndraDrive M


Dimensions HMS02.1N-W0054

A)
B)

Fig.6-54:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!

Dimensions HMS02.1N-W0054

148/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Dimensions, Mass, Insulation


Data for mass, dimensions, sound pressure level, insulation
Description

Symbol

Unit

HMS02.1N-W0028

HMS02.1N-W0054

Weight

kg

3,50

5,00

Device height (UL)1)

mm

352

Device depth (UL)2)

mm

205

Device width (UL)3)

mm

insulation resistance at DC 500 V

Ris

MOhm

>8

capacitance against housing

CY

nF

2 x 68

average sound pressure level (ac


curacy class 2) at PDC_cont 4)

LP

dB (A)

tbd

1) 2) 3)
4)

50

75

housing dimension; see also related dimension sheet


according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent

Fig.6-55:

HMS - Data for mass, dimensions, sound pressure level, insulation

Power Dissipation, Cooling, Distances


Data for cooling and power dissipation
Description
ambient temperature range

Symbol

Unit

Ta_work

0...40

0...55

%/K

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)
derating at Ta_work < Ta < Ta_work_red
2)

fTa

HMS02.1N-W0028

allowed mounting position

HMS02.1N-W0054

G1
f

cooling type3)
volumetric capacity of forced cool
ing4)

m3/h

17,20

tbd

allowed switching frequencies5)

fs

kHz

4, 8

4, 8, 12, 16

35

40

70

150

150,00

350,00

power dissipation at Iout_cont = 0 A;


fs = fs (min.)6)

Diss_0A_fsmi

power dissipation at Iout_cont = 0 A;


fs = fs (max.)7)

Diss_0A_fsma

power dissipation at continuous


current Iout_cont and DC bus power
PDC_cont respectively (UL)8)

PDiss_cont

minimum distance on the top of the


device9)

dtop

mm

80

minimum distance on the bottom of


the device10)

dbot

mm

80

P
x

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

149/315

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

temperature rise with minimum dis


tances dbot; dtop; PBD

65

temperature rise with minimum dis


tances dbot; dtop; cooling air current
fails; PBD

1)
2)
3)
4)
5)
6) 7)
8)
9) 10)

Fig.6-56:
Power Dissipation vs. Output Cur
rent

HMS02.1N-W0028

HMS02.1N-W0054

observe derating
data to be derated: PDC_cont; PBD; Iout_cont
n: natural convection; f: forced cooling
HLR: see following note regarding cooling
also depending on firmware and control section; see parameter de
scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS); find interim values by interpolation to P_Diss_cont
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS)
see fig. "Air intake and air outlet at drive controller"

HMS - Data for cooling and power dissipation

The figure below illustrates the connection between power dissipation and out
put current, depending on the switching frequency fs which was set at the drive
controller. See also Parameter Description "P-0-0001, Switching frequency of
the power output stage".
In addition, take the power at the braking resistor and the power
consumption of the control section into account. Both powers are
not contained in the figure.

Fig.6-57:

Power dissipation vs. output current

150/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Distances
Property damage due to temperatures higher than 105 C!
Comply with indicated minimum distances!

CAUTION

A
B
C
dtop
dbot

Fig.6-58:

air intake
air outlet
mounting surface in control cabinet
distance top
distance bottom

Air intake and air outlet at drive controller

Basic Data Power Section HMS02


General Information
This section contains

data for control voltage supply

data of DC bus

data of inverter
The order of the data tables below follows the energy flow in the
drive controller - from mains connection to motor output.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

151/315

Power Sections for Inverters - IndraDrive M

Control Voltage
Data for control voltage supply
Description

Symbol

Unit

rated control voltage input (UL)1)

UN3

24 20 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length < 50 m2)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length > 50 m3)

UN3

26 5 %

--

maximum allowed voltage for


1 ms5)

UN3_max

33 (1ms)

inrush current at 24V supply

IEIN3

4,80

pulse width of IEIN3

tEIN3Lade

ms

10

input capacitance

CN3

mF

1,20

rated power consumption control


voltage input without holding brake,
without control section at
UN3 = DC 24 V (UL)6)

PN3

internal control voltage (optional)7)

Ucontr_int

maximum ripple content4)

1) 2) 3)
4)
5)
6)
7)

HMS02.1N-W0028

HMS02.1N-W0054

13

17

observe supply voltage for motor holding brakes


absolute voltage values must be within UN3
see following note regarding overvoltage
find value for control section in project planning manual
value only with HCS02, HCS03: Types with order code -***V

Fig.6-59:

HMS - Data for control voltage supply

Overvoltage of more than 33 V has to be discharged by means of


the appropriate electrical equipment of the machine or installation.
This includes:

24V power supply units that reduce incoming overvoltage to


the allowed value.

Overvoltage limiters at the control cabinet input that limit ex


isting overvoltage to the allowed value. This, too, applies to
long 24V lines that have been run in parallel to power cables
and mains cables and can absorb overvoltage by inductive or
capacitive coupling.

DC Bus
Data of power section - DC bus
Description

Symbol

Unit

DC bus voltage range1)

UDC

capacitance in DC bus

CDC

mF

HMS02.1N-W0028

HMS02.1N-W0054
254...750

0,14

0,27

152/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description
maximum discharge time from
UR_DC_On to DC 50 V2)

Symbol

Unit

WDC

Ws

DC resistance in DC bus (L+ to L-)


at UDC = 750 V

RDC

ohm

continuous load kVA at cos=1

PDC

maximum possible load kVA at


cos=1

PDC

monitoring value minimum DC bus


voltage, undervoltage threshold5)

HMS02.1N-W0054

tentl_ZK

storable energy of internal DC bus


capacitance3)

monitoring value maximum DC bus


voltage, switch-off threshold4)

HMS02.1N-W0028

U
DC_limit_max

U
DC_limit_min

efficiency for nominal data

<230k

900

254

1)
2)
3)
4)
5)

depending on mains input voltage ULN


without other device on DC bus
at ULN_nenn to UR_DC_On
HMV: see also troubleshooting guide for E8025, F2817
HMV: see also troubleshooting guide for E2026, F2026; HCS: Depend
ing on parameter setting, see parameter description "P00114, Under
voltage threshold"

Fig.6-60:

HMS - Data of power section - DC bus

Inverter
Data of power section - Inverter
Description

Symbol

Unit

HMS02.1N-W0028

HMS02.1N-W0054

fs

kHz

4, 8

4, 8, 12, 16

output voltage, fundamental wave


with open-loop operation

Uout_eff

~ UDC x 0,71

output voltage, fundamental wave


with closed-loop operation

Uout_eff

~ UDC x 0,71

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-phase (1090%)2)

du/dt

kV/s

5,00

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-ground (1090%)3)

du/dt

kV/s

5,00

output frequency range at fs = 2 kHz

fout_2k

Hz

output frequency range at fs = 4 kHz

fout_4k

Hz

0...400

output frequency range at fs = 8 kHz

fout_8k

Hz

0...800

output frequency range at


fs = 12 kHz

fout_12k

Hz

0...1200

output frequency range at


fs = 16 kHz

fout_16k

Hz

0...1600

allowed switching frequencies1)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

153/315

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

maximum output current at


fs = 2 kHz

Iout_max2

maximum output current at


fs = 4 kHz

Iout_max4

28,3

54,0

maximum output current at


fs = 8 kHz

Iout_max8

28,3

54,0

maximum output current at


fs = 12 kHz

Iout_max12

54,0

maximum output current at


fs = 16 kHz

Iout_max16

40,0

allowed continuous output current


at fs = 2 kHz

Iout_cont2

allowed continuous output current


at fs = 4 kHz

Iout_cont4

13,8

25,0

allowed continuous output current


at fs = 8 kHz

Iout_cont8

8,5

20,0

allowed continuous output current


at fs = 12 kHz4)

Iout_cont12

12,7

allowed continuous output current


at fs = 16 kHz5)

Iout_cont16

10,2

allowed continuous output current


at fs = 2 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 4 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 8 kHz; output frequency
fout < fout_still
allowed continuous output current
at fs = 12 kHz; output frequency
fout < fout_still 6)
allowed continuous output current
at fs = 16 kHz; output frequency
fout < fout_still 7)

HMS02.1N-W0028

HMS02.1N-W0054
-

I
A

I
A

9,2

19,2

5,1

12,5

7,0

5,6

I
out_cont0Hz_
8

I
out_cont0Hz_
12

I
out_cont0Hz_
16

154/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description
output frequency threshold to de
tect motor standstill8)

Symbol

Unit

fout_still

Hz

HMS02.1N-W0028

HMS02.1N-W0054
2...4

assigned output filters at nom. da


ta; fs = 4 kHz

1)
2) 3)
4) 5) 6) 7)
8)

Fig.6-61:

also depending on firmware and control section; see parameter de


scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
guide value, see following note
see parameter description "P00556, Config word of axis controller",
load-depending reduction of PWM frequency fs
see following note regarding reduction output current

HMS - Data of power section - Inverter

Observe that the load is almost independent of the power section


used.
Especially when using standard motors , make sure that they com
ply with the occurring voltage load.
Observe the information contained in the chapter Third-Party Mo
tors at IndraDrive Controllers in the Project Planning Manual of the
drive system.
Depending on the electric output frequency, the output current is
reduced for thermal protection of the power section.
The output current is reduced, when the electric output frequency
has fallen below the threshold to detect motor standstill.

Exemplary Data for Applications


General Information
This section contains

examples of allowed current profiles

examples of allowed performance profiles

data for selecting standard motors

Current Profiles
Current Profile UEL_I_e

The following current profiles have been defined for converters and inverters.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

155/315

Power Sections for Inverters - IndraDrive M

Profile
Current profile UEL_I_e

Explanation

The characteris
tic data of the
profile are used
to select convert
ers and inverters
for operation with
standard motors
and servo drives.

Fig.6-62:

Definition of current profiles

Examples of allowed current profiles


Description

Symbol

Unit

Iout_peak1_2

base load current at Iout_peak_1;


Iout_base1_2
fs = 2 kHz; t = 0,4 s; T = 4 s; K = 2,5

maximum output current at


Iout_base_1; fs = 4 kHz; t = 0,4 s;
T = 4 s; K = 2,52)

Iout_peak1_4

23,11

48,74

base load current at Iout_peak_1;


Iout_base1_4
fs = 4 kHz; t = 0,4 s; T = 4 s; K = 2,5

9,25

19,50

maximum output current at


Iout_base_1; fs = 8 kHz; t = 0,4 s;
T = 4 s; K = 2,53)

Iout_peak1_8

14,13

31,93

base load current at Iout_peak_1;


Iout_base1_8
fs = 8 kHz; t = 0,4 s; T = 4 s; K = 2,5

5,65

12,77

maximum output current at


Iout_base_1; fs = 12 kHz; t = 0,4 s;
T = 4 s; K = 2,54)

20,49

8,20

16,56

6,62

maximum output current at


Iout_base_1; fs = 2 kHz; t = 0,4 s;
T = 4 s; K = 2,51)

base load current at Iout_peak_1;


fs = 12 kHz; t = 0,4 s; T = 4 s; K = 2,5
maximum output current at
Iout_base_1; fs = 16 kHz; t = 0,4 s;
T = 4 s; K = 2,55)
base load current at Iout_peak_1;
fs = 16 kHz; t = 0,4 s; T = 4 s; K = 2,5

I
out_peak1_12

I
out_base1_12

I
out_peak1_16

I
out_base1_16

maximum output current at


Iout_base_3; fs = 2 kHz; t = 2 s; T = 20 s; Iout_peak3_2
K = 2,06)

HMS02.1N-W0028

HMS02.1N-W0054

156/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

HMS02.1N-W0028

HMS02.1N-W0054

base load current at Iout_peak_3;


Iout_base3_2
fs = 2 kHz; t = 2 s; T = 20 s; K = 2,0

maximum output current at


Iout_base_3; fs = 4 kHz; t = 2 s; T = 20 s; Iout_peak3_4
K = 2,07)

21,88

43,44

base load current at Iout_peak_3;


Iout_base3_4
fs = 4 kHz; t = 2 s; T = 20 s; K = 2,0

10,94

21,72

maximum output current at


Iout_base_3; fs = 8 kHz; t = 2 s; T = 20 s; Iout_peak3_8
K = 2,08)

13,35

29,04

base load current at Iout_peak_3;


Iout_base3_8
fs = 8 kHz; t = 2 s; T = 20 s; K = 2,0

6,67

14,52

maximum output current at


Iout_base_3; fs = 12 kHz; t = 2 s;
T = 20 s; K = 2,09)

18,56

9,28

14,97

7,49

base load current at Iout_peak_3;


fs = 12 kHz; t = 2 s; T = 20 s; K = 2,0
maximum output current at
Iout_base_3; fs = 16 kHz; t = 2 s;
T = 20 s; K = 2,010)
base load current at Iout_peak_3;
fs = 16 kHz; t = 2 s; T = 20 s; K = 2,0

I
out_peak3_12

I
out_base3_12

I
out_peak3_16

I
out_base3_16

base load current at Iout_peak_4;


Iout_base4_2
fs = 2 kHz; t = 60 s; T = 5 min; K = 1,5

maximum output current at


Iout_base_4; fs = 2 kHz; t = 60 s;
T = 5 min; K = 1,511)

Iout_peak4_2

maximum output current at


Iout_base_4; fs = 4 kHz; t = 60 s;
T = 5 min; K = 1,512)

Iout_peak4_4

14,84

33,90

base load current at Iout_peak_4;


Iout_base4_4
fs = 4 kHz; t = 60 s; T = 5 min; K = 1,5

9,89

22,60

maximum output current at


Iout_base_4; fs = 8 kHz; t = 60 s;
T = 5 min; K = 1,513)

Iout_peak4_8

9,03

24,84

base load current at Iout_peak_4;


Iout_base4_8
fs = 8 kHz; t = 60 s; T = 5 min; K = 1,5

6,02

16,56

maximum output current at


Iout_base_4; fs = 12 kHz; t = 60 s;
T = 5 min; K = 1,514)

15,81

10,54

base load current at Iout_peak_4;


fs = 12 kHz; t = 60 s; T = 5 min;
K = 1,5

I
out_peak4_12

I
out_base4_12

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

157/315

Power Sections for Inverters - IndraDrive M


Description
maximum output current at
Iout_base_4; fs = 16 kHz; t = 60 s;
T = 5 min; K = 1,515)
base load current at Iout_peak_4;
fs = 16 kHz; t = 60 s; T = 5 min;
K = 1,5

Symbol
I
out_peak4_16

I
out_base4_16

Unit

HMS02.1N-W0028

HMS02.1N-W0054

12,74

8,49

maximum output current at


Iout_base_5; fs = 2 kHz; t = 60 s;
T = 10 min; K = 1,116)

Iout_peak5_2

base load current at Iout_peak_5;


fs = 2 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_2

maximum output current at


Iout_base_5; fs = 4 kHz; t = 60 s;
T = 10 min; K = 1,117)

Iout_peak5_4

14,23

26,35

base load current at Iout_peak_5;


fs = 4 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_4

12,93

23,95

maximum output current at


Iout_base_5; fs = 8 kHz; t = 60 s;
T = 10 min; K = 1,118)

Iout_peak5_8

8,65

20,79

base load current at Iout_peak_5;


fs = 8 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_8

7,87

18,90

13,21

12,00

10,63

9,66

maximum output current at


Iout_base_5; fs = 12 kHz; t = 60 s;
T = 10 min; K = 1,119)
base load current at Iout_peak_5;
fs = 12 kHz; t = 60 s; T = 10 min;
K = 1,1
maximum output current at
Iout_base_5; fs = 16 kHz; t = 60 s;
T = 10 min; K = 1,120)
base load current at Iout_peak_5;
fs = 16 kHz; t = 60 s; T = 10 min;
K = 1,1

I
out_peak5_12

I
out_base5_12

I
out_peak5_16

I
out_base5_16

1) 2) 3) 4) 5) 6) see definition profile UEL_I_e


7) 8) 9) 10)
11) 12) 13)
14) 15) 16)
17) 18) 19)
20)

Fig.6-63:

HMS - Examples of allowed current profiles

158/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Operation With Standard Motors


General Information
Selecting Standard Motors

The tables below contain the nominal power Pnenn of standard motors which
can be operated at the respective drive controller. The data are subject to the
following conditions:

motor design:
4-pole standard motor (2 pole pairs) with rated voltage 3AC400V, 50Hz at
mains voltage ULN 3AC400V or
4-pole standard motor (2 pole pairs) with rated voltage 3AC460V, 60Hz at
mains voltage ULN 3AC460V

assigned mains choke is used

operation at minimum switching frequency fs= fs (min.)

rotary field at output with fout>fout_still

ambient temperature TaTa_work

overload ratio K=PDC_peak/PDC_base according to performance profile


UEL_P_e

type of mains connection: individual supply


When choosing standard motors for HMS/HMD, additionally select
an appropriate HMV supply unit. Observe the performance data
PDC_peak and PDC_base in the performance profile UEL_P_e of the
supply unit.

Operation With Standard Motors


Operating Standard Motors at 3 AC 400 V
in preparation

Operating Standard Motors at 3 AC 460 V


in preparation

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

159/315

Power Sections for Inverters - IndraDrive M

6.3.5

Connections and Interfaces

Overview
Overall Connection Diagram
Overall connection diagram with mains filter, mains choke, supply unit, power
section

HNS02
HNL02
HMV02
HMS02

Fig.6-64:

mains filter
mains choke
supply unit
power section

Overall connection diagram (mains filter, mains choke, supply unit, pow
er section)

160/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Connection diagram of power section

Fig.6-65:

Connection diagram HMS02.1-Wxxxx

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

161/315

Power Sections for Inverters - IndraDrive M

Arrangement of the Connection Points

1)
2)
3)
X1 in, X1 out

Fig.6-66:

control voltage
DC bus
equipment grounding conductor
module bus

Connections at power section (front)

162/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

X5
X6
XS2

Fig.6-67:

motor connection
motor temperature monitoring and motor holding brake
shield connection (motor power cable)

Connections at power section (bottom)

Description of the Connection Points


The connection points are described in detail in chapter 8 Functions and Elec
trical Connection Points , page 255.
Touch Guard

The touch guard is described in detail in chapter 9 Touch Guard at Devices ,


page 299.

6.4

HMD01 Power Sections

6.4.1

Brief Description, Usage and Structure


Brief Description
Usage

The HMD01 inverters are part of the Rexroth IndraDrive M product range and
are used to operate 2 single axes.
The different types are used as follows:
Type

Usage

HMD01.1E-Wxxxx-NNNN

double-axis device

Operation of two three-phase a.c.


motors (asynchronous or synchro
nous motors).

Fig.6-68:

Usage of HMD01

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

163/315

Power Sections for Inverters - IndraDrive M


Structure, Block Diagrams

1)
2)

Fig.6-69:

6.4.2

inverter stages with output to motor


DC bus connection

HMD - block diagram

Type Code and Identification

Type Code
The following figure illustrates the basic structure of the type code.
Our sales representative will help you with the current status of
available versions.

164/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Fig.6-70:

Type code HMD01

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

165/315

Power Sections for Inverters - IndraDrive M

Identification
Type Plate Arrangement

1
2
3
Type Plate

power section type plate


control section type plate
firmware type plate

Fig.6-71:

Type plates at the drive controller

1
2
3
4
5
6
7

device type
part number
serial number
bar code
country of manufacture
production week, 04W12 meaning year 2004, week 12
hardware index

Fig.6-72:

Type plate - power section (example of an HCS02 power section)

166/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

6.4.3

6.4.4

Scope of Supply

1 touch guard

1 connector X5.1, X5.2, X6.1 and X6.2 each

Technical Data

Ambient and Operating Conditions


General Information
Conditions for transport and storage: see chapter 4.2 Transport and Storage,
page 19.
Installation conditions: see chapter 4.3 Installation Conditions , page 20.
This chapter contains:

limit values for use in the scope of C-UL

applied standards (CE conformity, UL listing)

UL Data
Ambient and operating conditions - UL ratings
Description

Symbol

Unit

HMD01.1N-W0012

HMD01.1N-W0036

Use copper 60/75 C only; class 1 or equivalent only

field wiring material (UL)1)


pollution degree (UL)
short circuit current rating, SCCR,
symmetrical amperes (UL)2)

HMD01.1N-W0020

Use in a pollution degree 2 environment


ISCCR

rated input voltage, power (UL)3)

A rms

42000

254..750VDC

maximum input current (UL)4)

IL_cont

maximum output voltage (UL)

Uout

maximum output current (UL)

Iout_max

1)
2)

3)
4)

Fig.6-73:

17,0

24,5

49,0

530
6,9

10,0

20,0

find value for tightening torque in project planning manual, Electrical


Connection Points
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
HMS, HMD, HLB, HLC: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
at PDC_cont

HMD - Ambient and operating conditions - UL ratings

Information on Standards
Applied standards
Description
CE conformity regarding Low-Volt
age Directive
CE conformity regarding EMC
product standard

Symbol

Unit

HMD01.1N-W0012

HMD01.1N-W0020
EN61800-5-1
EN61800-3

high-voltage test, test rate

100% (EN61800-5-1)

high-voltage and insulation test,


test rate

100% (EN61800-5-1)

HMD01.1N-W0036

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

167/315

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

HMD01.1N-W0012

HMD01.1N-W0020

listing according to UL standard


(UL)

UL 508 C

UL files (UL)

E 134201

listing according to CSA standard


(UL)

HMD01.1N-W0036

Canadian National Standard(s) C22.2 No. 14-05

Fig.6-74:

HMD - Applied standards

168/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Mechanical System and Mounting


Dimensional Drawings
HMD01.1N-W0012

A)
B)
C)
D)

Fig.6-75:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!
dimensions for accessory HAS02.1 when motor cable run with 45
dimensions for accessory HAS02.1 when motor cable run horizontally

Dimensions HMD01.1N-W0012

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

169/315

Power Sections for Inverters - IndraDrive M


HMD01.1N-W0020

A)
B)
C)
D)

Fig.6-76:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!
dimensions for accessory HAS02.1 when motor cable run with 45
dimensions for accessory HAS02.1 when motor cable run horizontally

Dimensions HMD01.1N-W0020

170/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


HMD01.1N-W0036

A)
B)
C)
D)

Fig.6-77:

minimum mounting clearance (plus additional space for motor cable)


Note: Rexroth IndraDrive supply units require greater mounting clear
ance!
rear view!
dimensions for accessory HAS02.1 when motor cable run with 45
dimensions for accessory HAS02.1 when motor cable run horizontally

Dimensions HMD01.1N-W0036

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

171/315

Power Sections for Inverters - IndraDrive M

Dimensions, Mass, Insulation, Sound Pressure Level


Data for mass, dimensions, sound pressure level, insulation
Description

Symbol

Unit

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

Weight

kg

5,50

5,60

7,50

Device height (UL)1)

mm

440

Device depth (UL)2)

mm

262

Device width (UL)3)

mm

insulation resistance at DC 500 V

Ris

MOhm

>50

capacitance against housing

CY

nF

136,00

average sound pressure level (ac


curacy class 2) at PDC_cont 4)

LP

dB (A)

tbd

1) 2) 3)
4)

50

75

housing dimension; see also related dimension sheet


according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent

Fig.6-78:

HMD - Data for mass, dimensions, sound pressure level, insulation

Power Dissipation, Cooling, Distances


Data for cooling and power dissipation
Description
ambient temperature range

Symbol

Unit

Ta_work

0...40

0...+55

%/K

2,0

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)
derating at Ta_work < Ta < Ta_work_red
2)

fTa

HMD01.1N-W0012

allowed mounting position

HMD01.1N-W0020

HMD01.1N-W0036

G1
f

cooling type3)
volumetric capacity of forced cool
ing4)

m3/h

tbd

allowed switching frequencies5)

fs

kHz

4, 8

power dissipation at Iout_cont = 0 A;


fs = fs (min.)6)

Diss_0A_fsmi

power dissipation at Iout_cont = 0 A;


fs = fs (max.)7)

Diss_0A_fsma

power dissipation at continuous


current Iout_cont and DC bus power
PDC_cont respectively (UL)8)

PDiss_cont

minimum distance on the top of the


device9)

dtop

mm

80

minimum distance on the bottom of


the device10)

dbot

mm

100

2 x 35

2 x 10

2 x 15

2 x 50

2 x 10

2 x 25

2 x 95

2 x 135

2 x 205

P
x

172/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

temperature rise with minimum dis


tances dbot; dtop; PBD

40

45

temperature rise with minimum dis


tances dbot; dtop; cooling air current
fails; PBD

40

45

1)
2)
3)
4)
5)
6) 7)
8)
9) 10)

Fig.6-79:

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

observe derating
data to be derated: PDC_cont; PBD; Iout_cont
n: natural convection; f: forced cooling
HLR: see following note regarding cooling
also depending on firmware and control section; see parameter de
scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS); find interim values by interpolation to P_Diss_cont
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS)
see fig. "Air intake and air outlet at drive controller"

HMD - Data for cooling and power dissipation

Property damage due to temperatures higher than 105 C!


Comply with indicated minimum distances!

CAUTION

A
B
C
dtop
dbot

Fig.6-80:

air intake
air outlet
mounting surface in control cabinet
distance top
distance bottom

Air intake and air outlet at drive controller

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

173/315

Power Sections for Inverters - IndraDrive M


Power Dissipation vs. Output Cur
rent

The figure below illustrates the connection between power dissipation and out
put current, depending on the switching frequency fs which was set at the drive
controller. See also Parameter Description "P-0-0001, Switching frequency of
the power output stage".
In addition, take the power at the braking resistor and the power
consumption of the control section into account. Both powers are
not contained in the figure.

Fig.6-81:

Power dissipation vs. output current

Basic Data Power Section HMD01


General Information
This section contains

data for control voltage supply

data of DC bus

data of inverter
The order of the data tables below follows the energy flow in the
drive controller - from mains connection to motor output.

Control Voltage
Data for control voltage supply
Description

Symbol

Unit

HMD01.1N-W0012

HMD01.1N-W0020

rated control voltage input (UL)1)

UN3

24 20 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length < 50 m2)

UN3

24 5 %

HMD01.1N-W0036

174/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

UN3

26 5 %

maximum allowed voltage for


1 ms5)

UN3_max

33 (1ms)

inrush current at 24V supply

IEIN3

tbd

pulse width of IEIN3

tEIN3Lade

ms

tbd

input capacitance

CN3

mF

tbd

rated power consumption control


voltage input without holding brake,
without control section at
UN3 = DC 24 V (UL)6)

PN3

internal control voltage (optional)7)

Ucontr_int

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length > 50 m3)
maximum ripple content4)

1) 2) 3)
4)
5)
6)
7)

HMD01.1N-W0012

HMD01.1N-W0020

17

HMD01.1N-W0036

11

observe supply voltage for motor holding brakes


absolute voltage values must be within UN3
see following note regarding overvoltage
find value for control section in project planning manual
value only with HCS02, HCS03: Types with order code -***V

Fig.6-82:

HMD - Data for control voltage supply

Overvoltage of more than 33 V has to be discharged by means of


the appropriate electrical equipment of the machine or installation.
This includes:

24V power supply units that reduce incoming overvoltage to


the allowed value.

Overvoltage limiters at the control cabinet input that limit ex


isting overvoltage to the allowed value. This, too, applies to
long 24V lines that have been run in parallel to power cables
and mains cables and can absorb overvoltage by inductive or
capacitive coupling.

DC Bus
Data of power section - DC bus
Description

Symbol

Unit

DC bus voltage range1)

UDC

254..750

capacitance in DC bus

CDC

mF

maximum discharge time from


UR_DC_On to DC 50 V2)

HMD01.1N-W0012

HMD01.1N-W0020

tentl_ZK

storable energy of internal DC bus


capacitance3)

WDC

Ws

DC resistance in DC bus (L+ to L-)


at UDC = 750 V

RDC

ohm

continuous load kVA at cos=1

PDC

kW

120,00

HMD01.1N-W0036

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

175/315

Power Sections for Inverters - IndraDrive M


Description
maximum possible load kVA at
cos=1

Symbol

Unit

PDC

kW

180,00

900

254

monitoring value maximum DC bus


voltage, switch-off threshold4)

DC_limit_max

monitoring value minimum DC bus


voltage, undervoltage threshold5)

DC_limit_min

efficiency for nominal data

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

0,93

1)
2)
3)
4)
5)

depending on mains input voltage ULN


without other device on DC bus
at ULN_nenn to UR_DC_On
HMV: see also troubleshooting guide for E8025, F2817
HMV: see also troubleshooting guide for E2026, F2026; HCS: Depend
ing on parameter setting, see parameter description "P00114, Under
voltage threshold"

Fig.6-83:

HMD - Data of power section - DC bus

Inverter
Data of power section - Inverter
Description

Symbol

Unit

fs

kHz

4, 8

output voltage, fundamental wave


with open-loop operation

Uout_eff

~ UDC x 0,71

output voltage, fundamental wave


with closed-loop operation

Uout_eff

~ UDC x 0,71

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-phase (1090%)2)

du/dt

kV/s

5,00

rise of voltage at output with


ULN_nenn and 15 m motor cable
length phase-ground (1090%)3)

du/dt

kV/s

5,00

output frequency range at fs = 2 kHz

fout_2k

Hz

output frequency range at fs = 4 kHz

fout_4k

Hz

0..400

output frequency range at fs = 8 kHz

fout_8k

Hz

0...800

output frequency range at


fs = 12 kHz

fout_12k

Hz

output frequency range at


fs = 16 kHz

fout_16k

Hz

maximum output current at


fs = 2 kHz

Iout_max2

maximum output current at


fs = 4 kHz

Iout_max4

12,0

20,0

36,0

maximum output current at


fs = 8 kHz

Iout_max8

12,0

20,0

36,0

allowed switching frequencies1)

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

176/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description

Symbol

Unit

maximum output current at


fs = 12 kHz

Iout_max12

maximum output current at


fs = 16 kHz

Iout_max16

allowed continuous output current


at fs = 2 kHz

Iout_cont2

allowed continuous output current


at fs = 4 kHz

Iout_cont4

6,9

10,0

20,0

allowed continuous output current


at fs = 8 kHz

Iout_cont8

3,7

6,1

13,0

allowed continuous output current


at fs = 12 kHz4)

Iout_cont12

allowed continuous output current


at fs = 16 kHz5)

Iout_cont16

allowed continuous output current


at fs = 2 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 4 kHz; output frequency
fout < fout_still

out_cont0Hz_

allowed continuous output current


at fs = 8 kHz; output frequency
fout < fout_still
allowed continuous output current
at fs = 12 kHz; output frequency
fout < fout_still 6)

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

--

I
2

I
A

4,4

7,0

13,7

1,7

4,1

8,9

I
out_cont0Hz_
8

I
out_cont0Hz_

Hz

2..4

12

allowed continuous output current


at fs = 16 kHz; output frequency
fout < fout_still 7)

out_cont0Hz_

output frequency threshold to de


tect motor standstill8)

fout_still

I
16

assigned output filters at nom. da


ta; fs = 4 kHz

1)
2) 3)
4) 5) 6) 7)
8)

Fig.6-84:

also depending on firmware and control section; see parameter de


scription "P00001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
guide value, see following note
see parameter description "P00556, Config word of axis controller",
load-depending reduction of PWM frequency fs
see following note regarding reduction output current

HMD - Data of power section - Inverter

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

177/315

Power Sections for Inverters - IndraDrive M


Observe that the load is almost independent of the power section
used.
Especially when using standard motors , make sure that they com
ply with the occurring voltage load.
Observe the information contained in the chapter Third-Party Mo
tors at IndraDrive Controllers in the Project Planning Manual of the
drive system.
Depending on the electric output frequency, the output current is
reduced for thermal protection of the power section.
The output current is reduced, when the electric output frequency
has fallen below the threshold to detect motor standstill.

Exemplary Data for Applications


General Information
This section contains

examples of allowed current profiles

examples of allowed performance profiles

data for selecting standard motors

Current Profiles
Examples of allowed current profiles
Description

Symbol

Unit

Iout_peak1_2

base load current at Iout_peak_1;


Iout_base1_2
fs = 2 kHz; t = 0,4 s; T = 4 s; K = 2,5

maximum output current at


Iout_base_1; fs = 4 kHz; t = 0,4 s;
T = 4 s; K = 2,52)

Iout_peak1_4

11,66

17,38

33,44

base load current at Iout_peak_1;


Iout_base1_4
fs = 4 kHz; t = 0,4 s; T = 4 s; K = 2,5

4,67

6,95

13,38

maximum output current at


Iout_base_1; fs = 8 kHz; t = 0,4 s;
T = 4 s; K = 2,53)

Iout_peak1_8

6,35

10,76

22,14

base load current at Iout_peak_1;


Iout_base1_8
fs = 8 kHz; t = 0,4 s; T = 4 s; K = 2,5

2,54

4,31

8,86

maximum output current at


Iout_base_1; fs = 12 kHz; t = 0,4 s;
T = 4 s; K = 2,54)

maximum output current at


Iout_base_1; fs = 2 kHz; t = 0,4 s;
T = 4 s; K = 2,51)

base load current at Iout_peak_1;


fs = 12 kHz; t = 0,4 s; T = 4 s; K = 2,5

I
out_peak1_12

I
out_base1_12

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

178/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description
maximum output current at
Iout_base_1; fs = 16 kHz; t = 0,4 s;
T = 4 s; K = 2,55)

Symbol
I

Unit

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

maximum output current at


Iout_base_3; fs = 2 kHz; t = 2 s; T = 20 s; Iout_peak3_2
K = 2,06)

base load current at Iout_peak_3;


Iout_base3_2
fs = 2 kHz; t = 2 s; T = 20 s; K = 2,0

maximum output current at


Iout_base_3; fs = 4 kHz; t = 2 s; T = 20 s; Iout_peak3_4
K = 2,07)

10,50

15,44

30,13

base load current at Iout_peak_3;


Iout_base3_4
fs = 4 kHz; t = 2 s; T = 20 s; K = 2,0

5,25

7,72

15,07

maximum output current at


Iout_base_3; fs = 8 kHz; t = 2 s; T = 20 s; Iout_peak3_8
K = 2,08)

5,67

9,52

19,79

base load current at Iout_peak_3;


Iout_base3_8
fs = 8 kHz; t = 2 s; T = 20 s; K = 2,0

2,84

4,76

9,89

maximum output current at


Iout_base_3; fs = 12 kHz; t = 2 s;
T = 20 s; K = 2,09)

base load current at Iout_peak_4;


Iout_base4_2
fs = 2 kHz; t = 60 s; T = 5 min; K = 1,5

maximum output current at


Iout_base_4; fs = 2 kHz; t = 60 s;
T = 5 min; K = 1,511)

Iout_peak4_2

maximum output current at


Iout_base_4; fs = 4 kHz; t = 60 s;
T = 5 min; K = 1,512)

Iout_peak4_4

8,01

11,72

23,37

base load current at Iout_peak_4;


Iout_base4_4
fs = 4 kHz; t = 60 s; T = 5 min; K = 1,5

5,34

7,81

15,58

maximum output current at


Iout_base_4; fs = 8 kHz; t = 60 s;
T = 5 min; K = 1,513)

4,29

7,19

15,23

base load current at Iout_peak_1;


fs = 16 kHz; t = 0,4 s; T = 4 s; K = 2,5

base load current at Iout_peak_3;


fs = 12 kHz; t = 2 s; T = 20 s; K = 2,0
maximum output current at
Iout_base_3; fs = 16 kHz; t = 2 s;
T = 20 s; K = 2,010)
base load current at Iout_peak_3;
fs = 16 kHz; t = 2 s; T = 20 s; K = 2,0

out_peak1_16

I
out_base1_16

I
out_peak3_12

I
out_base3_12

I
out_peak3_16

I
out_base3_16

Iout_peak4_8

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

179/315

Power Sections for Inverters - IndraDrive M


Description

Unit

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

base load current at Iout_peak_4;


Iout_base4_8
fs = 8 kHz; t = 60 s; T = 5 min; K = 1,5

2,86

4,79

10,16

maximum output current at


Iout_base_4; fs = 12 kHz; t = 60 s;
T = 5 min; K = 1,514)

base load current at Iout_peak_4;


fs = 12 kHz; t = 60 s; T = 5 min;
K = 1,5
maximum output current at
Iout_base_4; fs = 16 kHz; t = 60 s;
T = 5 min; K = 1,515)
base load current at Iout_peak_4;
fs = 16 kHz; t = 60 s; T = 5 min;
K = 1,5

Symbol

I
out_peak4_12

I
out_base4_12

I
out_peak4_16

I
out_base4_16

maximum output current at


Iout_base_5; fs = 2 kHz; t = 60 s;
T = 10 min; K = 1,116)

Iout_peak5_2

base load current at Iout_peak_5;


fs = 2 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_2

maximum output current at


Iout_base_5; fs = 4 kHz; t = 60 s;
T = 10 min; K = 1,117)

Iout_peak5_4

7,25

10,49

20,93

base load current at Iout_peak_5;


fs = 4 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_4

6,59

9,54

19,02

maximum output current at


Iout_base_5; fs = 8 kHz; t = 60 s;
T = 10 min; K = 1,118)

Iout_peak5_8

3,87

6,43

13,60

base load current at Iout_peak_5;


fs = 8 kHz; t = 60 s; T = 10 min;
K = 1,1

Iout_base5_8

3,52

5,84

12,36

maximum output current at


Iout_base_5; fs = 12 kHz; t = 60 s;
T = 10 min; K = 1,119)
base load current at Iout_peak_5;
fs = 12 kHz; t = 60 s; T = 10 min;
K = 1,1

I
out_peak5_12

I
out_base5_12

180/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M


Description
maximum output current at
Iout_base_5; fs = 16 kHz; t = 60 s;
T = 10 min; K = 1,120)
base load current at Iout_peak_5;
fs = 16 kHz; t = 60 s; T = 10 min;
K = 1,1

Symbol
I
out_peak5_16

I
out_base5_16

Unit

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

1) 2) 3) 4) 5) 6) see definition profile UEL_I_e


7) 8) 9) 10)
11) 12) 13)
14) 15) 16)
17) 18) 19)
20)

Fig.6-85:
Current Profile UEL_I_e

HMD - Examples of allowed current profiles

The following current profiles have been defined for converters and inverters.
Profile
Current profile UEL_I_e

Explanation

The characteris
tic data of the
profile are used
to select convert
ers and inverters
for operation with
standard motors
and servo drives.

Fig.6-86:

Definition of current profiles

Operation With Standard Motors


General Information
Selecting Standard Motors

The tables below contain the nominal power Pnenn of standard motors which
can be operated at the respective drive controller. The data are subject to the
following conditions:

motor design:
4-pole standard motor (2 pole pairs) with rated voltage 3AC400V, 50Hz at
mains voltage ULN 3AC400V or
4-pole standard motor (2 pole pairs) with rated voltage 3AC460V, 60Hz at
mains voltage ULN 3AC460V

assigned mains choke is used

operation at minimum switching frequency fs= fs (min.)

rotary field at output with fout>fout_still

ambient temperature TaTa_work

overload ratio K=PDC_peak/PDC_base according to performance profile


UEL_P_e

type of mains connection: individual supply

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

181/315

Power Sections for Inverters - IndraDrive M


When choosing standard motors for HMS/HMD, additionally select
an appropriate HMV supply unit. Observe the performance data
PDC_peak and PDC_base in the performance profile UEL_P_e of the
supply unit.

Operating Standard Motors at 3 AC 400 V


Selection of standard motors 3 AC 400V - Exemplary profiles
Description

Symbol

Unit

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

nominal power standard motor


3 AC 400 V; 50 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

3,00

4,00

7,50

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

2,20

4,00

7,50

nominal power standard motor


3 AC 400 V; 50 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

2,20

3,00

7,50

nominal power standard motor


3 AC 400 V; 50 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

2,20

3,00

7,50

1) 2) 3) 4)

see definition profile UEL_P_e


HMD - Selection of standard motors 3 AC 400V - Exemplary profiles

Fig.6-87:

Operating Standard Motors at 3 AC 460 V


Selection of standard motors 3 AC 460V - Exemplary profiles
Description

Symbol

Unit

HMD01.1N-W0012

HMD01.1N-W0020

HMD01.1N-W0036

nominal power standard motor


3AC460V; 60 Hz; t > 10 min;
K = 1,0; fs = 4 kHz1)

PNenn

kW

3,70

5,50

11,00

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 10 min; K = 1,1; fs = 4 kHz2)

PNenn

kW

2,20

3,70

11,00

nominal power standard motor


3AC460V; 60 Hz; t = 60 s;
T = 5 min; K = 1.5; fs = 4 kHz3)

PNenn

kW

2,20

3,70

7,40

nominal power standard motor


3AC460V; 60 Hz; t = 2 s; T = 20 s;
K = 2,0; fs = 4 kHz4)

PNenn

kW

2,20

3,70

7,40

1) 2) 3) 4)

Fig.6-88:
Performance Profile UEL_P_e

see definition profile UEL_P_e; 1 kW ~ 1,36 hp


HMD - Selection of standard motors 3 AC 460V - Exemplary profiles

The following performance profiles have been defined for converters and in
verters.
Observe the allowed performance data PDC_peak and PDC_base in the
corresponding performance profile of the supply unit or converter.

182/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Profile
Performance profile UEL_P_e

Explanation

Characteristic of
the selection of
standard motors
and servo drives.

Fig.6-89:

Definition of performance profiles, infeeding supply units and converters

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

183/315

Power Sections for Inverters - IndraDrive M

6.4.5

Connections and Interfaces

Overview
Overall Connection Diagram

Fig.6-90:

Connection diagram HMD01

184/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Power Sections for Inverters - IndraDrive M

Arrangement of the Connection Points


Connection Points at HMD01.1N-W0012, HMD01.1N-W0020 and
HMD01.1N-W0036
Connections at power section (front)

1)
2)
3)
X1 in, X1 out

Fig.6-91:

control voltage
DC bus
equipment grounding conductor
module bus

Connections at power section (front)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

185/315

Power Sections for Inverters - IndraDrive M


Connections at power section (bottom) HMD01.1N-W0012, HMD01.1NW0020, -W0036

X5.1, X5.2
X6.1, X6.2
XS2

Fig.6-92:

motor connection
motor temperature monitoring and motor holding brake
shield connection (motor power cable)

Connections at power section (bottom)

Description of the Connection Points


The connection points are described in detail in chapter 8 Functions and Elec
trical Connection Points , page 255.
Touch Guard

The touch guard is described in detail in chapter 9 Touch Guard at Devices ,


page 299.

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

187/315

IndraDrive M Supply Units

IndraDrive M Supply Units

7.1

Types

Supply unit

Characteristic

Type

HMV01.1E

infeeding

W0030
W0075

Features
to supply HMS01 and HMD01 drive
controllers

W0120
HMV01.1R

regenerative

W0018
W0045

to supply HMS01 and HMD01 drive


controllers

W0065
W0120
HMV02.1R

regenerative

Fig.7-1:

W0015

Overview

7.2

HMV01.1E Supply Units, Infeeding

7.2.1

Brief Description, Usage and Structure


Brief Description
Usage

to supply HMS02 drive controllers

HMV supply units are used to supply modular HMS and HMD devices.
The different types can be used as follows:
Type
HMV01.1E

Fig.7-2:

Usage
infeeding
to supply HMS01 and HMD01 drive controllers

Usage of supply units

188/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Structure

1
2
3

Fig.7-3:

7.2.2

interfaces for signal processing


control panel
power connections incl. control voltage

Basic design

Type Code and Identification

Type Code
The following figure illustrates the basic structure of the type code.
Our sales representative will help you with the current status of
available versions.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

189/315

IndraDrive M Supply Units

Fig.7-4:

Type code

190/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Identification
Type Plate Arrangement

Type Plate

Fig.7-5:

Type plate at device

1
2
3
4
5
6
7

device type
part number
serial number
bar code
country of manufacture
production week, 04W12 meaning year 2004, week 12
hardware index

Fig.7-6:

7.2.3

Type plate - power section (example of an HCS02 power section)

Scope of Supply

1 touch guard

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

191/315

IndraDrive M Supply Units

7.2.4

1 connector X14 (only HMV01.1R), X31, X32 and X33 each

1 joint bar to connect the equipment grounding conductor to a neigh


boring device

1 standard control panel each

1 brochure with safety instructions (in 5 languages)

Technical Data HMV01.1E

Ambient and Operating Conditions


General Information
Conditions for transport and storage: see chapter 4.2 Transport and Storage,
page 19.
Installation conditions: see chapter 4.3 Installation Conditions , page 20.
This chapter contains:

limit values for use in the scope of C-UL

applied standards (CE conformity, UL listing)

UL Data
Ambient and operating conditions - UL ratings
Description

Symbol

Unit

HMV01.1E-W0030

HMV01.1E-W0120

Use copper 60/75 C only; class 1 or equivalent only

field wiring material (UL)1)


pollution degree (UL)
short circuit current rating, SCCR,
symmetrical amperes (UL)2)

HMV01.1E-W0075

Use in a pollution degree 2 environment


ISCCR

rated input voltage, power (UL)3)

A rms

42000

380...480

maximum input current (UL)4)

IL_cont

maximum output voltage (UL)

Uout

maximum output current (UL)

Iout_max

1)
2)

3)
4)

Fig.7-7:

51,0

128,0

204,0

435...710 dc
30,0

75,0

120,0

find value for tightening torque in project planning manual, Electrical


Connection Points
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
HMS, HMD, HLB, HLC: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
at PDC_cont

HMV - Ambient and operating conditions - UL ratings

Information on Standards
Applied standards
Description
CE conformity regarding Low-Volt
age Directive
CE conformity regarding EMC
product standard
high-voltage test, test rate

Symbol

Unit

HMV01.1E-W0030

HMV01.1E-W0075
EN61800-5-1
EN61800-3
100% (EN61800-5-1)

HMV01.1E-W0120

192/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Description

Symbol

Unit

HMV01.1E-W0030

HMV01.1E-W0075

high-voltage and insulation test,


test rate

100% (EN61800-5-1)

listing according to UL standard


(UL)

UL 508 C

UL files (UL)

E 134201

listing according to CSA standard


(UL)

HMV01.1E-W0120

Canadian National Standard(s) C22.2 No. 14-05

Fig.7-8:

HMV - Applied standards

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

193/315

IndraDrive M Supply Units

Mechanical System and Mounting


Dimensions

A)
*)

Fig.7-9:

minimum mounting clearance


plus additional clearance for mains connection cable (the required clear
ance depends on the minimum bending radius of the connected mains
connection cable)

Dimensions

194/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Device

L1

[mm]

[mm]

HMV01.1E-W0030

150

100

HMV01.1E-W0075

250

200

HMV01.1E-W0120

350

300

Fig.7-10:

Dimensions

Mass, Sound Pressure Level, Insulation


Data for mass, dimensions, sound pressure level, insulation
Description
Weight

Symbol

Unit

HMV01.1E-W0030

HMV01.1E-W0075

HMV01.1E-W0120

13,50

22,00

32,00

kg

(UL)1)

mm

440

Device depth (UL)2)

mm

262

(UL)3)

mm

insulation resistance at DC 500 V

Ris

MOhm

tbd

capacitance against housing

CY

nF

tbd

average sound pressure level (ac


curacy class 2) at PDC_cont 4)

LP

dB (A)

tbd

Device height

Device width

1) 2) 3)
4)

150

250

350

housing dimension; see also related dimension sheet


according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent

Fig.7-11:

HMV - Data for mass, dimensions, sound pressure level, insulation

Power Dissipation, Cooling, Distances


Data for cooling and power dissipation
Description
ambient temperature range

Symbol

Unit

Ta_work

0...+40

0...55

%/K

2,0

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)
derating at Ta_work < Ta < Ta_work_red
2)

fTa

HMV01.1E-W0030

HMV01.1E-W0075

HMV01.1E-W0120

cooling type3)
volumetric capacity of forced cool
ing4)

power dissipation at continuous


current Iout_cont and DC bus power
PDC_cont respectively (UL)5)

PDiss_cont

minimum distance on the top of the


device6)

dtop

mm

330

minimum distance on the bottom of


the device7)

dbot

mm

130

150,00

340,00

500,00

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

195/315

IndraDrive M Supply Units


Description

Symbol

Unit

temperature rise with minimum dis


tances dbot; dtop; PBD

65

temperature rise with minimum dis


tances dbot; dtop; cooling air current
fails; PBD

1)
2)
3)
4)
5)
6) 7)

Fig.7-12:

HMV01.1E-W0030

HMV01.1E-W0075

HMV01.1E-W0120

observe derating
data to be derated: PDC_cont; PBD; Iout_cont
n: natural convection; f: forced cooling
HLR: see following note regarding cooling
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS)
see fig. "Air intake and air outlet at drive controller"

HMV - Data for cooling and power dissipation

Distances
Property damage due to temperatures higher than 105 C!
Comply with indicated minimum distances!

CAUTION

A
B
C
dtop
dbot

Fig.7-13:

air intake
air outlet
mounting surface in control cabinet
distance top
distance bottom

Air intake and air outlet at drive controller

196/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Basic Data Supply Unit HMV01, Infeeding


General Information
This section contains

data for control voltage supply

data for mains voltage supply

data of DC bus

data of built-in braking resistor and requirements on an external braking


resistor

data for cooling and power dissipation


The order of the data tables below follows the energy flow in the
drive controller - from mains connection to DC bus output.

Control Voltage
Data for control voltage supply
Description

Symbol

Unit

rated control voltage input (UL)1)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length < 50 m2)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length > 50 m3)

UN3

26 5 %

maximum allowed voltage for


1 ms5)

UN3_max

28,80

inrush current at 24V supply

IEIN3

pulse width of IEIN3

tEIN3Lade

ms

input capacitance

CN3

mF

rated power consumption control


voltage input without holding brake,
without control section at
UN3 = DC 24 V (UL)6)

PN3

internal control voltage (optional)7)

Ucontr_int

maximum ripple content4)

1) 2) 3)
4)
5)
6)
7)

Fig.7-14:

HMV01.1E-W0030

HMV01.1E-W0075

5,00

5,50
15

HMV01.1E-W0120

10,00
50

tbd

25

30

55

observe supply voltage for motor holding brakes


absolute voltage values must be within UN3
see following note regarding overvoltage
find value for control section in project planning manual
value only with HCS02, HCS03: Types with order code -***V

HMV - Data for control voltage supply

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

197/315

IndraDrive M Supply Units


Overvoltage of more than 33 V has to be discharged by means of
the appropriate electrical equipment of the machine or installation.
This includes:

24V power supply units that reduce incoming overvoltage to


the allowed value.

Overvoltage limiters at the control cabinet input that limit ex


isting overvoltage to the allowed value. This, too, applies to
long 24V lines that have been run in parallel to power cables
and mains cables and can absorb overvoltage by inductive or
capacitive coupling.

Mains Voltage
Data for mains voltage supply
Description
input frequency (UL)

Symbol

Unit

fLN

Hz

50...60

Hz

Hz/s

tolerance input frequency (UL)


maximum allowed mains frequen
cy change

fLN/t

HMV01.1E-W0030

rotary field condition


short circuit current rating, SCCR,
symmetrical amperes (UL)1)

HMV01.1E-W0075

-ISCCR

A rms

42000

ULN_nenn

3 AC 400

mains voltage single-phase

ULN

--

mains voltage three-phase at TN S,


TN C, TT mains

ULN

380...480

mains voltage three-phase at IT


mains

ULN

200...230

mains voltage three-phase at Cor


ner-grounded-Delta mains2)

ULN

200...230

10

40

nominal mains voltage

tolerance ULN (UL)


minimum inductance of the mains
supply (inductance of mains
phase)3)

Lmin

assigned type of mains choke, type


of mains filter combination
minimum short circuit power of the
mains for failure-free operation4)

Sk_min

MVA

HNL01.1E-0400N0051-A-480

HNL01.1E-0200N0125-A-480

HNL01.1E-0100N0202-A-480

1,6

3,4

5,4

I
maximum inrush

current5)

L_trans_max_

I L_cont

on

maximum allowed ON-Off cycles


per minute6)
power factor TPF (L) at PDC_cont
with mains choke; ULN_nenn

HMV01.1E-W0120

1
TPF

0,88

198/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Description
power factor TPF (L) at PDC_cont
without mains choke; ULN_nenn 7)

Symbol

Unit

HMV01.1E-W0030

HMV01.1E-W0075

HMV01.1E-W0120

TPF

0,64

TPF10

0,40

TPF

power factor of fundam. compo


nent DPF at PDC_cont with mains
choke9)

cosh1

0,97

power factor of fundam. compo


nent DPF at PDC_cont without mains
choke10)

cosh1

0,97

mains connection power at


PDC_cont; ULN_nenn with mains choke

SLN

kVA

35,00

86,00

tbd

mains connection power at


PDC_cont; ULN_nenn without mains
choke

SLN

kVA

31,00

68,00

108,00

maximum input current (UL)11)

IL_cont

51,0

128,0

204,0

63

160

250

power factor TPF (L) at 10%


PDC_cont without mains choke;
ULN_nenn 8)
power factor TPF (L) at PDC_cont
(single-phase); ULN = 1 AC 230 V

recommended mains fuse at nom.


data with mains choke; ULN_nenn
recommended mains contactor at
nom. data with mains choke;
ULN_nenn 12)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

199/315

IndraDrive M Supply Units


Description

Symbol

Unit

HMV01.1E-W0030

HMV01.1E-W0075

HMV01.1E-W0120

required wire size according to


IEC 60364552; at IL_cont 13)

ALN

mm2

10

50

95

required wire size according to


UL 508 A (internal wiring); at IL_cont
(UL)14)

ALN

AWG 6

AWG 1

AWG 4/0

1)

2)
3)
4)
5)
6)
7) 8)
9) 10)
11)
12)
13)
14)

Fig.7-15:

Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
mains voltage > ULN: use a transformer with grounded neutral point,
dont use autotransformers!
otherwise use mains choke HNL
HMV0x.xR: Rsc=100; HMV0x.xE, HCS0x.xE: Rsc=50
depending on mains input voltage ULN; HMV01.1R see following note;
HMV: constant current charge, HCS: resistance charge; minimum of
250.000 load cycles
without external capacities on DC bus
find interim values by interpolation
c: leading reactive; i: reactive
at PDC_cont
i: mains contactor integrated
copper wire; PVC-insulation (conductor temperature 70 C); installation
method B2; Table B52-4; Ta 40 C
copper wire; PVC-insulation (conductor temperature 90 C); Table
13.5.1; Ta 40 C

HMV - Data for mains voltage supply

Qualitative characteristic TPF vs. DC bus power PDC_cont

1
2

Fig.7-16:

characteristic with mains choke


characteristic without mains choke

Qualitative characteristic TPF vs. DC bus power PDC_cont

200/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

DC Bus
Data of supply unit - DC bus
Description
DC bus voltage range1)
nominal value of regulated DC bus
voltage2)
capacitance in DC bus
maximum discharge time from
UR_DC_On to DC 50 V3)

Symbol

Unit

HMV01.1E-W0030

UDC

ULN x 1,41

UDC_nenn

CDC

mF

1,41

HMV01.1E-W0075

HMV01.1E-W0120

3,76

5,64

tentl_ZK

storable energy of internal DC bus


capacitance4)

WDC

Ws

tbd

DC resistance in DC bus (L+ to L-)


at UDC = 750 V

RDC

ohm

tbd

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; with mains choke5)

PDC_cont

kW

30,00

75,00

120,00

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; without mains choke6)

PDC_cont

kW

18,00

45,00

72,00

changing PDC_cont and PDC_max vs.


mains input voltage; ULN ULN_nenn

fP_DC_lo

%/V

0,0025

changing PDC_cont and PDC_max vs.


mains input voltage; ULN > ULN_nenn

fP_DC_hi

%/V

0,0025

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; with mains
choke7)

PDC_max

kW

45,00

112,50

180,00

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; without mains
choke8)

PDC_max

kW

45,00

112,50

180,00

balancing factor for PDC_cont (for


parallel operation at common DC
bus) with mains choke

tbd

balancing factor for PDC_cont (for


parallel operation at common DC
bus) without mains choke

tbd
U

monitoring value maximum DC bus


voltage, switch-off threshold9)

DC_limit_max

monitoring value minimum DC bus


voltage, undervoltage threshold10)

DC_limit_min

charging resistor continuous power

PDC_Start

900

0,75*sqr2*U<t>LN</t>

kW

--

tbd

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

201/315

IndraDrive M Supply Units


Description

Symbol

Unit

maximum allowed external DC bus


capacitance

CDCext

mF

charging time at maximum allowed


CDCext external DC bus capacitance
at ULN_nenn

lade_DC_Cex

maximum allowed DC bus charg


ing energy to external capacitors

HMV01.1E-W0030

HMV01.1E-W0075

HMV01.1E-W0120

150,00

t
t

Wmax

kWs

1)
2)
3)
4)
5) 6)
7) 8)
9)
10)

--

tbd

depending on mains input voltage ULN


only devices with regulated DC bus voltage
without other device on DC bus
at ULN_nenn to UR_DC_On
observe factors f Ta; f P_DC; HMV: without fs; without fout
observe factors f Ta; f P_DC
HMV: see also troubleshooting guide for E8025, F2817
HMV: see also troubleshooting guide for E2026, F2026; HCS: Depend
ing on parameter setting, see parameter description "P00114, Under
voltage threshold"

Fig.7-17:

HMV - Data of supply unit - DC bus

fP_DC_hi
fP_DC_lo

factor in range ULN>ULNnenn


factor in range ULNULNnenn

Fig.7-18:

Characteristic of DC bus continuous power PDC versus mains connec


tion voltage ULN

Braking Resistor
Data of built-in braking resistor
Description

Symbol

Unit

HMV01.1E-W0030

HMV01.1E-W0075

HMV01.1E-W0120

braking resistor continuous power1)

PBD

kW

1,50

2,00

2,50

braking resistor peak power at


UDC = 850 V2)

PBS

kW

36,00

90,00

130,00

ohm

14

nominal braking resistance

RDC_Bleed
er

202/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Description
maximum braking resistance at
PBD
braking resistor switch-on thresh
old - mains voltage independent3)
braking resistor switch-on thresh
old - mains voltage dependent4)

Symbol
RDC_Bleed
er

UR_DC_On_f

Unit

HMV01.1E-W0030

HMV01.1E-W0075

HMV01.1E-W0120

ohm

16

820

ULN * 1,41 + 80V

R_DC_On_v

maximum allowed duty cycle at


Tcycl

EDrel

tbd

minimum allowed cycle time

Tcycl

tbd

maximum regenerative power to be


absorbed

WR_max

kWs

balancing factor for PBD (for parallel


operation at common DC bus)

100,00

250,00

500,00

tbd
f

cooling of internal braking resistor5)


1)
2)
3) 4)
5)

Fig.7-19:

observe derating factor f Ta; 0 kW when ext. braking resistor is used


0: no internal braking resistor; 0 kW when ext. braking resistor is used
factory setting; with HCS see parameter description "P-0-0833, Braking
resistor threshold" and "P-0-0860, Converter configuration"; with HMV
see X32
n: natural convection; f: forced cooling

HMV - Data of built-in braking resistor

Exemplary Data for Applications


General Information
This section contains

examples of allowed performance profiles

Performance Profiles
Performance Profiles of Infeeding
Supply Units

The following performance profiles have been defined for infeeding supply
units.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

203/315

IndraDrive M Supply Units

Profile
performance profile WZM_HS_KB_e

Explanation
The characteris
tic data of the
profile are used
to select infeed
ing and regener
ative supply
units.
Characteristic of
applications in
machine tools,
short-time oper
ation of the main
spindle.

performance profile WZM_HS_Fr_e


The characteris
tic data of the
profile are used
to select infeed
ing supply units.
Characteristic of
main spindles in
milling ma
chines.

performance profile WZM_SA_acc_e


The characteris
tic data of the
profile are used
to select infeed
ing supply units.
Characteristic of
servo drives at
machine tools.

204/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Profile
performance profile DRM_S1_acc_e

Explanation

The characteris
tic data of the
profile are used
to select infeed
ing and regener
ative supply
units.
Characteristic of
starting and op
eration at print
ing machines.

performance profile UEL_P_e


The characteris
tic data of the
profile are used
to select infeed
ing and regener
ative supply
units.
Characteristic of
applications us
ing standard mo
tors in overload
operation.

Fig.7-20:

Definitions of performance profiles, infeeding supply units

Examples of allowed performance profiles, supply units HMV....E


Description
DC bus power at ULN_nenn; t = 132 s;
T = 300 s; without mains choke1)
maximum DC bus power at
ULN_nenn; t = 132 s; T = 300 s; with
out mains choke2)
DC bus power at ULN_nenn; t = 132 s;
T = 300 s; with mains choke3)
maximum DC bus power at
ULN_nenn; t = 132 s; T = 300 s; with
mains choke4)
DC bus power at ULN_nenn; t = 3 s;
t = 60 s; without mains choke5)
maximum DC bus power at
ULN_nenn; t = 3 s; t = 60 s; without
mains choke6)

Symbol
P
DC_base_10

P
DC_peak_10

P
DC_base_10

P
DC_peak_10

P
DC_base_11

P
DC_peak_11

Unit

HMV01.1E-W0030

kW

kW

HMV01.1E-W0075

HMV01.1E-W0120

0,0

24,30

kW

60,70

97,20

0,0

kW

40,50

97,50

162,00

kW

9,00

22,50

36,00

kW

39,60

94,50

180,00

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

205/315

IndraDrive M Supply Units


Description
DC bus power at ULN_nenn; t = 3 s;
t = 60 s; with mains choke7)
maximum DC bus power at
ULN_nenn; t = 3 s; t = 60 s; with mains
choke8)
DC bus power at ULN_nenn; t = 0.2 s;
T = 4 s; without mains choke9)
maximum DC bus power at
ULN_nenn; t = 0.2 s; T = 4 s; without
mains choke10)
DC bus power at ULN_nenn; t = 0.2 s;
T = 4 s; with mains choke11)
maximum DC bus power at
ULN_nenn; t = 0.2 s; T = 4 s; with
mains choke12)
DC bus power at ULN_nenn; t = 60 s;
T = 900 s; without mains choke13)
maximum DC bus power at
ULN_nenn; t = 60 s; T = 900 s; without
mains choke14)
DC bus power at ULN_nenn; t = 60 s;
T = 900 s; with mains choke15)
maximum DC bus power at
ULN_nenn; t = 60 s; T = 900 s; with
mains choke16)

Symbol
P
DC_base_11

P
DC_peak_11

P
DC_base_12

P
DC_peak_12

P
DC_base_12

P
DC_peak_12

P
DC_base_13

P
DC_peak_13

P
DC_base_13

P
DC_peak_13

Unit

HMV01.1E-W0030

HMV01.1E-W0075

HMV01.1E-W0120

kW

16,50

41,20

66,00

kW

45,00

112,50

180,00

kW

kW

45,00

kW

112,50

180,00

0,0

kW

45,00

112,50

180,00

kW

16,20

40,50

64,80

kW

36,00

72,00

180,00

kW

27,00

67,50

108,00

kW

45,00

101,20

180,00

1) 2) 3) 4)
5) 6) 7) 8)
9) 10) 11) 12)
13) 14) 15)
16)

Fig.7-21:

0,0

see definition profile WZM_HS_KB_e


see definition profile WZM_HS_Fr_e
see definition profile WZM_SA_acc_e
see definition profile DRM_S1_acc_e

HMV....E - Examples of allowed performance profiles

206/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

7.2.5

Connections and Interfaces

Overview
Overall Connection Diagram

Fig.7-22:

Connection diagram

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

207/315

IndraDrive M Supply Units

Arrangement of the Connection Points


Connections HMV01.1E-W0030 and HMV01.1E-W0075

X33
X32
X31
X2
X1
X3
1)
2)
3)

Fig.7-23:

acknowledge messages of mains contactor


mains contactor control and DC bus short circuit (ZKS)
connection for messages
RS232
module bus
mains connection
control panel
control voltage
DC bus

Connections HMV01.1E-W0030 and HMV01.1E-W0075

208/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Connections HMV01.1E-W0120

X33
X32
X31
X2
X1
X3
1)
2)
3)
4)
5)

Fig.7-24:

acknowledge messages of mains contactor


mains contactor control and DC bus short circuit (ZKS)
connection for messages
RS232
module bus
mains connection
control panel
control voltage
DC bus
connection point of equipment grounding conductor (with joint bar to
neighboring device)
connection point of equipment grounding conductor (mains)

Connections HMV01.1E-W0120

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

209/315

IndraDrive M Supply Units

Description of the Connection Points


The connection points are described in detail in chapter 8 Functions and Elec
trical Connection Points , page 255.
Touch Guard

The touch guard is described in detail in chapter 9 Touch Guard at Devices ,


page 299.

7.3

HMV01.1R Supply Units, Regenerative

7.3.1

Brief Description, Usage and Structure


Brief Description
Usage

HMV supply units are used to supply modular HMS and HMD devices.
The different types can be used as follows:
Type
HMV01.1R

Structure

Usage
regenerative
to supply HMS01 and HMD01 drive controllers

Fig.7-25:

Usage of supply units

1
2
3

interfaces for signal processing


control panel
power connections incl. control voltage

Fig.7-26:

Basic design

210/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

7.3.2

Type Code and Identification

Type Code
The following figure illustrates the basic structure of the type code.
Our sales representative will help you with the current status of
available versions.

Fig.7-27:

Type code

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

211/315

IndraDrive M Supply Units

Identification
Type Plate Arrangement

Type Plate

Fig.7-28:

Type plate at device

1
2
3
4
5
6
7

device type
part number
serial number
bar code
country of manufacture
production week, 04W12 meaning year 2004, week 12
hardware index

Fig.7-29:

7.3.3

Type plate - power section (example of an HCS02 power section)

Scope of Supply

1 touch guard

212/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

7.3.4

1 connector X14 (only HMV01.1R), X31, X32 and X33 each

1 joint bar to connect the equipment grounding conductor to a neigh


boring device

1 standard control panel each

1 brochure with safety instructions (in 5 languages)

Technical Data HMV01.1R

Ambient and Operating Conditions


General Information
Conditions for transport and storage: see chapter 4.2 Transport and Storage,
page 19.
Installation conditions: see chapter 4.3 Installation Conditions , page 20.
This chapter contains:

limit values for use in the scope of C-UL

applied standards (CE conformity, UL listing)

UL Data
Ambient and operating conditions - UL ratings
Description

Symbol

Unit

HMV01.1RW0018

HMV01.1RW0065

HMV01.1RW0120

Use copper 60/75 C only; class 1 or equivalent only

field wiring material (UL)1)


pollution degree (UL)
short circuit current rating, SCCR,
symmetrical amperes (UL)2)

HMV01.1RW0045

Use in a pollution degree 2 environment


ISCCR

rated input voltage, power (UL)3)

A rms

42000

380...480

maximum input current (UL)4)

IL_cont

maximum output voltage (UL)

Uout

maximum output current (UL)

Iout_max

1)
2)

3)
4)

Fig.7-30:

26,0

65,0

94,0

181,0

65,0

120,0

750 dc
18,0

45,0

find value for tightening torque in project planning manual, Electrical


Connection Points
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
HMS, HMD, HLB, HLC: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
at PDC_cont

HMV - Ambient and operating conditions - UL ratings

Information on Standards
Applied standards
Description
CE conformity regarding Low-Volt
age Directive
CE conformity regarding EMC
product standard

Symbol

Unit

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

EN61800-5-1
EN61800-3

HMV01.1RW0120

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

213/315

IndraDrive M Supply Units

Description

Symbol

Unit

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

high-voltage test, test rate

100% (EN61800-5-1)

high-voltage and insulation test,


test rate

100% (EN61800-5-1)

listing according to UL standard


(UL)

UL 508 C

UL files (UL)

E 134201

listing according to CSA standard


(UL)

HMV01.1RW0120

Canadian National Standard(s) C22.2 No. 14-05

Fig.7-31:

HMV - Applied standards

214/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Mechanical System and Mounting


Dimensions

A)
*)

Fig.7-32:

minimum mounting clearance


plus additional clearance for mains connection cable (the required clear
ance depends on the minimum bending radius of the connected mains
connection cable)

Dimensions

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

215/315

IndraDrive M Supply Units

Device

L1

[mm]

[mm]

HMV01.1R-W0018

175

125

HMV01.1R-W0045

250

200

HMV01.1R-W0065

350

300

Fig.7-33:

Dimensions

Mass, Sound Pressure Level, Insulation


Data for mass, dimensions, sound pressure level, insulation
Symbol

Unit

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

HMV01.1RW0120

Weight

kg

13,50

20,00

31,00

34,50

Device height (UL)1)

mm

440

Device depth (UL)2)

mm

262

Device width (UL)3)

mm

insulation resistance at DC 500 V

Ris

MOhm

tbd

capacitance against housing

CY

nF

tbd

average sound pressure level (ac


curacy class 2) at PDC_cont 4)

LP

dB (A)

tbd

Description

1) 2) 3)
4)

175

250

350

housing dimension; see also related dimension sheet


according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent

Fig.7-34:

HMV - Data for mass, dimensions, sound pressure level, insulation

Power Dissipation, Cooling, Distances


Data for cooling and power dissipation
Description
ambient temperature range

derating at Ta_work < Ta < Ta_work_red

HMV01.1RW0045

HMV01.1RW0065

Unit

Ta_work

0...+40

0...55

%/K

2,0

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)
2)

HMV01.1RW0018

Symbol

fTa

allowed mounting position

HMV01.1RW0120

G1
f

cooling type3)
volumetric capacity of forced cool
ing4)

m3/h

power dissipation at continuous


current Iout_cont and DC bus power
PDC_cont respectively (UL)5)

PDiss_cont

minimum distance on the top of the


device6)

dtop

mm

tbd

290,00

680,00

800,00

330

2000,00

216/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Description

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

Symbol

Unit

minimum distance on the bottom of


the device7)

dbot

mm

temperature rise with minimum dis


tances dbot; dtop; PBD

65

temperature rise with minimum dis


tances dbot; dtop; cooling air current
fails; PBD

65

1)
2)
3)
4)
5)
6) 7)

Fig.7-35:

130

334

observe derating
data to be derated: PDC_cont; PBD; Iout_cont
n: natural convection; f: forced cooling
HLR: see following note regarding cooling
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS)
see fig. "Air intake and air outlet at drive controller"

HMV - Data for cooling and power dissipation

Distances
Property damage due to temperatures higher than 105 C!
Comply with indicated minimum distances!

CAUTION

HMV01.1RW0120

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

217/315

IndraDrive M Supply Units

A
B
C
dtop
dbot

Fig.7-36:

air intake
air outlet
mounting surface in control cabinet
distance top
distance bottom

Air intake and air outlet at drive controller

Basic Data Supply Unit HMV01, Regenerative


General Information
This section contains

data for control voltage supply

data for mains voltage supply

data of DC bus

data of built-in braking resistor and requirements on an external braking


resistor

data for cooling and power dissipation


The order of the data tables below follows the energy flow in the
drive controller - from mains connection to DC bus output.

218/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Control Voltage
Data for control voltage supply
Description

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

HMV01.1RW0120

Symbol

Unit

rated control voltage input (UL)1)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length < 50 m2)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length > 50 m3)

UN3

26 5 %

maximum allowed voltage for


1 ms5)

UN3_max

28,80

inrush current at 24V supply

IEIN3

pulse width of IEIN3

tEIN3Lade

ms

15

2000

input capacitance

CN3

mF

10,00

1,00

rated power consumption control


voltage input without holding brake,
without control section at
UN3 = DC 24 V (UL)6)

PN3

internal control voltage (optional)7)

Ucontr_int

maximum ripple content4)

1) 2) 3)
4)
5)
6)
7)

5,50

31

7,00

7,50

41

108

13,00

224

observe supply voltage for motor holding brakes


absolute voltage values must be within UN3
see following note regarding overvoltage
find value for control section in project planning manual
value only with HCS02, HCS03: Types with order code -***V

Fig.7-37:

HMV - Data for control voltage supply

Overvoltage of more than 33 V has to be discharged by means of


the appropriate electrical equipment of the machine or installation.
This includes:

24V power supply units that reduce incoming overvoltage to


the allowed value.

Overvoltage limiters at the control cabinet input that limit ex


isting overvoltage to the allowed value. This, too, applies to
long 24V lines that have been run in parallel to power cables
and mains cables and can absorb overvoltage by inductive or
capacitive coupling.

Mains Voltage
Data for mains voltage supply
Description
input frequency (UL)
tolerance input frequency (UL)

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

Symbol

Unit

fLN

Hz

50...60

Hz

HMV01.1RW0120

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

219/315

IndraDrive M Supply Units

Description

Symbol

Unit

maximum allowed mains frequen


cy change

fLN/t

Hz/s

HMV01.1RW0018

HMV01.1RW0045

-ISCCR

A rms

42000

ULN_nenn

3 AC 400

mains voltage three-phase at TN S,


TN C, TT mains

ULN

380...480

mains voltage three-phase at IT


mains

ULN

200...230

mains voltage three-phase at Cor


ner-grounded-Delta mains2)

ULN

200...230

10

40

nominal mains voltage

tolerance ULN (UL)


minimum inductance of the mains
supply (inductance of mains
phase)3)

Lmin

HNL01.1R-098 HNL01.1R-059 HNL01.1R-054


0-C00260-C00650-C0094HNL01.1R-030
A-480;
A-480;
A-480;
0-C0180HNL01.1R-420 HNL01.1R-630 HNL01.1R-300
A-480
0-S00260-S00650-S0094A-480
A-480
A-480

assigned type of mains choke, type


of mains filter combination

minimum short circuit power of the


mains for failure-free operation4)

HMV01.1RW0120

rotary field condition


short circuit current rating, SCCR,
symmetrical amperes (UL)1)

HMV01.1RW0065

Sk_min

MVA

1,9

4,7

6,8

13,2

40,00

94,00

150,00

I L_cont

I
maximum inrush current5)

L_trans_max_
on

maximum allowed ON-Off cycles


per minute6)

power factor TPF (L) at PDC_cont


with mains choke; ULN_nenn

TPF

0,99

power factor of fundam. compo


nent DPF at PDC_cont with mains
choke7)

cosh1

0,97

mains connection power at


PDC_cont; ULN_nenn with mains choke
maximum input current (UL)8)
recommended mains fuse at nom.
data with mains choke; ULN_nenn
recommended mains contactor at
nom. data with mains choke;
ULN_nenn 9)

SLN

kVA

19,00

47,00

68,00

132,00

IL_cont

26,0

65,0

94,0

181,0

35

80

125

224

3RT1064

220/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Symbol

Unit

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

HMV01.1RW0120

required wire size according to


IEC 60364552; at IL_cont 10)

ALN

mm2

16

35

95

required wire size according to


UL 508 A (internal wiring); at IL_cont
(UL)11)

ALN

AWG 10

AWG 6

AWG 3

AWG 3/0

Description

1)

Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
mains voltage > ULN: use a transformer with grounded neutral point,
dont use autotransformers!
otherwise use mains choke HNL
HMV0x.xR: Rsc=100; HMV0x.xE, HCS0x.xE: Rsc=50
depending on mains input voltage ULN; HMV01.1R see following note;
HMV: constant current charge, HCS: resistance charge; minimum of
250.000 load cycles
without external capacities on DC bus
c: leading reactive; i: reactive
at PDC_cont
i: mains contactor integrated
copper wire; PVC-insulation (conductor temperature 70 C); installation
method B2; Table B52-4; Ta 40 C
copper wire; PVC-insulation (conductor temperature 90 C); Table
13.5.1; Ta 40 C

2)
3)
4)
5)
6)
7)
8)
9)
10)
11)

Fig.7-38:

HMV - Data for mains voltage supply

In the switch-on sequence of the supply unit, the supplying mains


is loaded with the current IL_trans_max_on for the purpose of analysis.
When the supplying mains is unloaded, voltage peaks can occur at
the mains components (e.g. mains filters), e.g. caused by the leak
age inductance of the mains transformer.
If you have 3 or more HMV supply units at the common supply
mains, switch them on one after the other, with a delay of at least
0.5 sec. so that the inrush currents are not added!

DC Bus
Data of supply unit - DC bus
Description
DC bus voltage range1)
nominal value of regulated DC bus
voltage2)
capacitance in DC bus
maximum discharge time from
UR_DC_On to DC 50 V3)

HMV01.1RW0018

HMV01.1RW0045

Symbol

Unit

UDC

UDC_nenn

750

CDC

mF

0,70

1,88

tentl_ZK

storable energy of internal DC bus


capacitance4)

WDC

Ws

tbd

DC resistance in DC bus (L+ to L-)


at UDC = 750 V

RDC

ohm

HMV01.1RW0065

HMV01.1RW0120

2,82

4,95

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

221/315

IndraDrive M Supply Units

Description

Symbol

Unit

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

HMV01.1RW0120

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; with mains choke5)

PDC_cont

kW

18,00

45,00

65,00

120,00

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; without mains choke6)

PDC_cont

kW

--

changing PDC_cont and PDC_max vs.


mains input voltage; ULN ULN_nenn

fP_DC_lo

%/V

0,0025

changing PDC_cont and PDC_max vs.


mains input voltage; ULN > ULN_nenn

fP_DC_hi

%/V

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; with mains
choke7)

PDC_max

kW

162,00

180,00

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; without mains
choke8)

PDC_max

kW

45,00

112,00

--

balancing factor for PDC_cont (for


parallel operation at common DC
bus) with mains choke

balancing factor for PDC_cont (for


parallel operation at common DC
bus) without mains choke

monitoring value maximum DC bus


voltage, switch-off threshold9)

U
DC_limit_max

900

0,75 x 1,41 x ULN

monitoring value minimum DC bus


voltage, undervoltage threshold10)

DC_limit_min

charging resistor continuous power

PDC_Start

kW

maximum allowed external DC bus


capacitance

CDCext

mF

150,00

222/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Description
charging time at maximum allowed
CDCext external DC bus capacitance
at ULN_nenn
maximum allowed DC bus charg
ing energy to external capacitors

Symbol

Unit

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

HMV01.1RW0120

t
lade_DC_Cex
t

Wmax

kWs

1)
2)
3)
4)
5) 6)
7) 8)
9)
10)

tbd

depending on mains input voltage ULN


only devices with regulated DC bus voltage
without other device on DC bus
at ULN_nenn to UR_DC_On
observe factors f Ta; f P_DC; HMV: without fs; without fout
observe factors f Ta; f P_DC
HMV: see also troubleshooting guide for E8025, F2817
HMV: see also troubleshooting guide for E2026, F2026; HCS: Depend
ing on parameter setting, see parameter description "P00114, Under
voltage threshold"

Fig.7-39:

HMV - Data of supply unit - DC bus

fP_DC_hi
fP_DC_lo

factor in range ULN>ULNnenn


factor in range ULNULNnenn

Fig.7-40:

Characteristic of DC bus continuous power PDC versus mains connec


tion voltage ULN

Braking Resistor
Data of built-in braking resistor
Description

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

HMV01.1RW0120

Symbol

Unit

braking resistor continuous power1)

PBD

kW

braking resistor peak power at


UDC = 850 V2)

PBS

kW

36,00

90,00

130,00

--

ohm

19

--

nominal braking resistance

RDC_Bleed
er

0,40

--

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

223/315

IndraDrive M Supply Units

Description
maximum braking resistance at
PBD
braking resistor switch-on thresh
old - mains voltage independent3)
braking resistor switch-on thresh
old - mains voltage dependent4)

Symbol
RDC_Bleed
er

UR_DC_On_f

Unit

HMV01.1RW0018

HMV01.1RW0045

HMV01.1RW0065

HMV01.1RW0120

ohm

21

--

820

--

R_DC_On_v

--

ULN * 1,41 + 80V

--

maximum allowed duty cycle at


Tcycl

EDrel

tbd

--

minimum allowed cycle time

Tcycl

tbd

--

maximum regenerative power to be


absorbed

WR_max

kWs

balancing factor for PBD (for parallel


operation at common DC bus)

80,00

100,00

150,00
--

cooling of internal braking resistor5)


1)
2)
3) 4)
5)

--

Fig.7-41:

--

observe derating factor f Ta; 0 kW when ext. braking resistor is used


0: no internal braking resistor; 0 kW when ext. braking resistor is used
factory setting; with HCS see parameter description "P-0-0833, Braking
resistor threshold" and "P-0-0860, Converter configuration"; with HMV
see X32
n: natural convection; f: forced cooling

HMV - Data of built-in braking resistor

Exemplary Data for Applications


General Information
This section contains

examples of allowed performance profiles

Performance Profiles
Performance Profiles of Regenera
tive Supply Units

The following profiles have been defined for regenerative supply units.

224/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Profile
performance profile WZM_HS_KB_e

Explanation
The characteris
tic data of the
profile are used
to select infeed
ing and regener
ative supply
units.
Characteristic of
applications in
machine tools,
short-time oper
ation of the main
spindle.

performance profile WZM_HS_Fr_r

The characteris
tic data of the
profile are used
to select regen
erative supply
units.
Characteristic of
main spindles in
milling ma
chines.

performance profile WZM_SA_acc_r

The characteris
tic data of the
profile are used
to select regen
erative supply
units.
Characteristic of
servo drives at
machine tools.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

225/315

IndraDrive M Supply Units


Profile
performance profile DRM_S1_acc_e

Explanation

The characteris
tic data of the
profile are used
to select infeed
ing and regener
ative supply
units.
Characteristic of
starting and op
eration at print
ing machines.

performance profile DRM_S1_acc_r

The characteris
tic data of the
profile are used
to select regen
erative supply
units.
Characteristic of
deceleration at
printing ma
chines.

performance profile UEL_P_e


The characteris
tic data of the
profile are used
to select infeed
ing and regener
ative supply
units.
Characteristic of
applications us
ing standard mo
tors in overload
operation.

Fig.7-42:

Definitions of performance profiles, regenerative supply units

226/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Examples of allowed performance profiles, supply units HMV....R
Description
DC bus power at ULN_nenn; t = 132 s;
T = 300 s; with mains choke1)
maximum DC bus power at
ULN_nenn; t = 132 s; T = 300 s; with
mains choke2)
DC bus power at ULN_nenn; t = 6 s;
t = 60 s; with mains choke3)
maximum DC bus power at
ULN_nenn; t = 6 s; t = 60 s; with mains
choke4)
DC bus power at ULN_nenn; t = 0.4 s;
T = 4 s; with mains choke5)
maximum DC bus power at
ULN_nenn; t = 0.4 s; T = 4 s; with
mains choke6)
DC bus power at ULN_nenn; t = 60 s;
T = 900 s; with mains choke7)
maximum DC bus power at
ULN_nenn; t = 60 s; T = 900 s; with
mains choke8)

Symbol
P
DC_base_14

P
DC_peak_14

P
DC_base_15

P
DC_peak_15

P
DC_base_16

P
DC_peak_16

P
DC_base_17

P
DC_peak_17

1) 2) 4)
3)
5) 6) 8)
7)

Fig.7-43:

Unit

HMV01.1RW0018

HMV01.1RW0045

kW

HMV01.1RW0065

HMV01.1RW0120

kW

21,60

45,00

68,20

tbd

kW

3,60

9,00

13,00

24,00

kW

45,00

103,50

133,20

tbd

kW

kW

45,00

112,50

162,50

tbd

kW

16,20

40,50

58,50

108,00

kW

32,40

63,00

97,50

tbd

see definition profile WZM_HS_KB_e


see definition profile WZM_HS_Fr_r
see definition profile WZM_SA_acc_r
see definition profile DRM_S1_acc_r

HMV....R - Examples of allowed performance profiles

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

227/315

IndraDrive M Supply Units

7.3.5

Connections and Interfaces

Overview
Overall Connection Diagram

Fig.7-44:

Connection diagram

228/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Arrangement of the Connection Points


Connections HMV01.1R-W0018, -W0045, -W0065

X33
X32
X31
X2
X14
X3
X1
1)
2)
3)

Fig.7-45:

acknowledge messages of mains contactor


mains contactor control and DC bus short circuit (ZKS)
connection for messages
RS232
mains voltage synchronization
mains connection
module bus
control panel
control voltage
DC bus

Connections HMV01.1R-W0018, -W0045, -W0065

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

229/315

IndraDrive M Supply Units


Connections HMV01.1R-W0120

X34
X33
X32
X31
X2
X14
X13
X3
X1
1)
2)
3)
4)

Fig.7-46:

contact for external mains contactor


acknowledge messages of mains contactor
mains contactor control and DC bus short circuit (ZKS)
connection for messages
RS232
mains voltage synchronization
voltage connection for blower unit
mains connection
module bus
control panel
control voltage
DC bus
connection point of equipment grounding conductor (mains)

Connections HMV01.1R-W0120

230/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Description of the Connection Points


The connection points are described in detail in chapter 8 Functions and Elec
trical Connection Points , page 255.
Touch Guard

The touch guard is described in detail in chapter 9 Touch Guard at Devices ,


page 299.

7.4

HMV02.1R Supply Units, Regenerative

7.4.1

Brief Description, Usage and Structure


Brief Description
Usage

HMV supply units are used to supply modular HMS and HMD devices.
The different types can be used as follows:
Type
HMV02.1R

Fig.7-47:

Usage
regenerative
to supply HMS02 drive controllers

Usage of supply units

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

231/315

IndraDrive M Supply Units


Structure

1
2
3

Fig.7-48:

7.4.2

interfaces for signal processing


control panel
power connections incl. control voltage

Basic design

Type Code and Identification

Type Code
The following figure illustrates the basic structure of the type code.
Our sales representative will help you with the current status of
available versions.

232/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Fig.7-49:

Type code

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

233/315

IndraDrive M Supply Units

Identification
Type Plate Arrangement

Type Plate

Fig.7-50:

Type plate at device

1
2
3
4
5
6
7

device type
part number
serial number
bar code
country of manufacture
production week, 04W12 meaning year 2004, week 12
hardware index

Fig.7-51:

7.4.3

Type plate - power section (example of an HCS02 power section)

Scope of Supply
The scope of supply of the power section includes

1 x touch guard

1 x connector X31, X32 and X33 each

234/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

7.4.4

1 x joint bar to connect the equipment grounding conductor to a neigh


boring device

1 x standard control panel each

1 x brochure with safety instructions (in 5 languages)

Technical Data HMV02.1R

Ambient and Operating Conditions


General Information
Conditions for transport and storage: see chapter 4.2 Transport and Storage,
page 19.
Installation conditions: see chapter 4.3 Installation Conditions , page 20.
This chapter contains:

limit values for use in the scope of C-UL

applied standards (CE conformity, UL listing)

UL Data
Ambient and operating conditions - UL ratings
Description

Symbol

Unit

HMV02.1R-W0015
Use copper 60/75 C only; class 1 or equivalent only

field wiring material (UL)1)


pollution degree (UL)
short circuit current rating, SCCR,
symmetrical amperes (UL)2)

Use in a pollution degree 2 environment


ISCCR

rated input voltage, power (UL)3)

A rms

42000

380...480

maximum input current (UL)4)

IL_cont

23,0

maximum output voltage (UL)

Uout

750 dc

maximum output current (UL)

Iout_max

20,0

1)
2)

3)
4)

Fig.7-52:

find value for tightening torque in project planning manual, Electrical


Connection Points
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
HMS, HMD, HLB, HLC: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
at PDC_cont

HMV - Ambient and operating conditions - UL ratings

Information on Standards
Applied standards
Description
CE conformity regarding Low-Volt
age Directive
CE conformity regarding EMC
product standard
high-voltage test, test rate

Symbol

Unit

HMV02.1R-W0015
EN61800-5-1
EN61800-3
100% (EN61800-5-1)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

235/315

IndraDrive M Supply Units


Description

Symbol

Unit

HMV02.1R-W0015

high-voltage and insulation test,


test rate

100% (EN61800-5-1)

listing according to UL standard


(UL)

UL 508 C

UL files (UL)

E 134201

listing according to CSA standard


(UL)

Canadian National Standard(s) C22.2 No. 14-05

Fig.7-53:

HMV - Applied standards

236/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Mechanical System and Mounting


Dimensions

A
B

Fig.7-54:

minimum mounting clearance (plus additional clearance for mains con


nection cable (the required clearance depends on the minimum bending
radius of the connected mains connection cable))
rear view!

Dimensional drawing

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

237/315

IndraDrive M Supply Units

Mass, Sound Pressure Level, Insulation


Data for mass, dimensions, sound pressure level, insulation
Description

Symbol

Unit

HMV02.1R-W0015

Weight

kg

9,50

Device height (UL)1)

mm

352

Device depth (UL)2)

mm

205

Device width (UL)3)

mm

150

insulation resistance at DC 500 V

Ris

MOhm

5,00

capacitance against housing

CY

nF

2x 470

average sound pressure level (ac


curacy class 2) at PDC_cont 4)

LP

dB (A)

75

1) 2) 3)
4)

housing dimension; see also related dimension sheet


according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent

Fig.7-55:

HMV - Data for mass, dimensions, sound pressure level, insulation

Power Dissipation, Cooling, Distances


Data for cooling and power dissipation
Description
ambient temperature range

Symbol

Unit

HMV02.1R-W0015

Ta_work

0..+40

0...55

%/K

2,7

ambient temperature range during


operation with reduced nominal da Ta_work_red
ta1)
derating at Ta_work < Ta < Ta_work_red
2)

fTa

allowed mounting position

G1
f

cooling type3)
volumetric capacity of forced cool
ing4)

m3/h

115,00

power dissipation at continuous


current Iout_cont and DC bus power
PDC_cont respectively (UL)5)

PDiss_cont

500,00

minimum distance on the top of the


device6)

dtop

mm

80

minimum distance on the bottom of


the device7)

dbot

mm

80

238/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Description

Symbol

Unit

HMV02.1R-W0015

temperature rise with minimum dis


tances dbot; dtop; PBD

65

temperature rise with minimum dis


tances dbot; dtop; cooling air current
fails; PBD

65

1)
2)
3)
4)
5)
6) 7)

Fig.7-56:

observe derating
data to be derated: PDC_cont; PBD; Iout_cont
n: natural convection; f: forced cooling
HLR: see following note regarding cooling
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS)
see fig. "Air intake and air outlet at drive controller"

HMV - Data for cooling and power dissipation

Distances
Property damage due to temperatures higher than 105 C!
Comply with indicated minimum distances!

CAUTION

A
B
C
dtop
dbot

Fig.7-57:

air intake
air outlet
mounting surface in control cabinet
distance top
distance bottom

Air intake and air outlet at drive controller

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

239/315

IndraDrive M Supply Units

Basic Data Supply Unit HMV02, Regenerative


General Information
This section contains

data for control voltage supply

data for mains voltage supply

data of DC bus

data of built-in braking resistor and requirements on an external braking


resistor

data for cooling and power dissipation


The order of the data tables below follows the energy flow in the
drive controller - from mains connection to DC bus output.

Control Voltage
Data for control voltage supply
Description

Symbol

Unit

HMV02.1R-W0015

rated control voltage input (UL)1)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length < 50 m2)

UN3

24 5 %

recommended Ctrl voltage when


using motor holding brake with mo
tor cable length > 50 m3)

UN3

26 5 %

maximum allowed voltage for


1 ms5)

UN3_max

33,00

inrush current at 24V supply

IEIN3

5,50

pulse width of IEIN3

tEIN3Lade

ms

15

input capacitance

CN3

mF

10,00

rated power consumption control


voltage input without holding brake,
without control section at
UN3 = DC 24 V (UL)6)

PN3

27

internal control voltage (optional)7)

Ucontr_int

maximum ripple content4)

1) 2) 3)
4)
5)
6)
7)

Fig.7-58:

observe supply voltage for motor holding brakes


absolute voltage values must be within UN3
see following note regarding overvoltage
find value for control section in project planning manual
value only with HCS02, HCS03: Types with order code -***V

HMV - Data for control voltage supply

240/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Overvoltage of more than 33 V has to be discharged by means of
the appropriate electrical equipment of the machine or installation.
This includes:

24V power supply units that reduce incoming overvoltage to


the allowed value.

Overvoltage limiters at the control cabinet input that limit ex


isting overvoltage to the allowed value. This, too, applies to
long 24V lines that have been run in parallel to power cables
and mains cables and can absorb overvoltage by inductive or
capacitive coupling.

Mains Voltage
Data for mains voltage supply
Description
input frequency (UL)

Symbol

Unit

HMV02.1R-W0015

fLN

Hz

50...60

Hz

Hz/s

tolerance input frequency (UL)


maximum allowed mains frequen
cy change

fLN/t

rotary field condition


short circuit current rating, SCCR,
symmetrical amperes (UL)1)

ISCCR

A rms

42000

ULN_nenn

3 AC 400

mains voltage three-phase at TN S,


TN C, TT mains

ULN

380...480

mains voltage three-phase at IT


mains

ULN

200...230

mains voltage three-phase at Cor


ner-grounded-Delta mains2)

ULN

200...230

10

50

nominal mains voltage

tolerance ULN (UL)


minimum inductance of the mains
supply (inductance of mains
phase)3)

Lmin

assigned type of mains choke, type


of mains filter combination
minimum short circuit power of the
mains for failure-free operation4)

HNL02.1R-0980-C0023-A-480
Sk_min

MVA

1,6

I L_cont

I
maximum inrush current5)

L_trans_max_
on

maximum allowed ON-Off cycles


per minute6)
power factor TPF (L) at PDC_cont
with mains choke; ULN_nenn

1
TPF

0,99

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

241/315

IndraDrive M Supply Units


Description

Symbol

power factor of fundam. compo


nent DPF at PDC_cont with mains
choke7)

cosh1

mains connection power at


PDC_cont; ULN_nenn with mains choke
maximum input current (UL)8)

Unit

HMV02.1R-W0015
0,97

SLN

kVA

15,75

IL_cont

23,0

35

recommended mains fuse at nom.


data with mains choke; ULN_nenn
recommended mains contactor at
nom. data with mains choke;
ULN_nenn 9)

required wire size according to


IEC 60364552; at IL_cont 10)

ALN

required wire size according to


UL 508 A (internal wiring); at IL_cont
(UL)11)

ALN

mm2

AWG 10

1)

Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with listed
AC input line fuses or listed circuit breakers specified in this documen
tation.
mains voltage > ULN: use a transformer with grounded neutral point,
dont use autotransformers!
otherwise use mains choke HNL
HMV0x.xR: Rsc=100; HMV0x.xE, HCS0x.xE: Rsc=50
depending on mains input voltage ULN; HMV01.1R see following note;
HMV: constant current charge, HCS: resistance charge; minimum of
250.000 load cycles
without external capacities on DC bus
c: leading reactive; i: reactive
at PDC_cont
i: mains contactor integrated
copper wire; PVC-insulation (conductor temperature 70 C); installation
method B2; Table B52-4; Ta 40 C
copper wire; PVC-insulation (conductor temperature 90 C); Table
13.5.1; Ta 40 C

2)
3)
4)
5)
6)
7)
8)
9)
10)
11)

Fig.7-59:

HMV - Data for mains voltage supply

DC Bus
Data of supply unit - DC bus
Description
DC bus voltage range1)
nominal value of regulated DC bus
voltage2)
capacitance in DC bus
maximum discharge time from
UR_DC_On to DC 50 V3)
storable energy of internal DC bus
capacitance4)

Symbol

Unit

HMV02.1R-W0015

UDC

UDC_nenn

750

CDC

mF

0,70

Ws

198,00

tentl_ZK
WDC

242/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Description

Symbol

Unit

HMV02.1R-W0015

DC resistance in DC bus (L+ to L-)


at UDC = 750 V

RDC

ohm

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; with mains choke5)

PDC_cont

kW

15,00

rated power (t > 10 min) at


fs = 4 kHz; output frequency
fout > fout_still; ULN_nenn; control factor
a0>0,8; without mains choke6)

PDC_cont

kW

changing PDC_cont and PDC_max vs.


mains input voltage; ULN ULN_nenn

fP_DC_lo

%/V

0,0025

changing PDC_cont and PDC_max vs.


mains input voltage; ULN > ULN_nenn

fP_DC_hi

%/V

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; with mains
choke7)

PDC_max

kW

30,00

maximum allowed DC bus power at


ULN_nenn = ULN_nenn; without mains
choke8)

PDC_max

kW

balancing factor for PDC_cont (for


parallel operation at common DC
bus) with mains choke

balancing factor for PDC_cont (for


parallel operation at common DC
bus) without mains choke

monitoring value maximum DC bus


voltage, switch-off threshold9)

DC_limit_max

monitoring value minimum DC bus


voltage, undervoltage threshold10)

DC_limit_min

charging resistor continuous power


maximum allowed external DC bus
capacitance

900

600

PDC_Start

kW

CDCext

mF

50,00

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

243/315

IndraDrive M Supply Units


Description
charging time at maximum allowed
CDCext external DC bus capacitance
at ULN_nenn
maximum allowed DC bus charg
ing energy to external capacitors

Symbol

Unit

HMV02.1R-W0015

kWs

13,70

t
lade_DC_Cex
t

Wmax
1)
2)
3)
4)
5) 6)
7) 8)
9)
10)

depending on mains input voltage ULN


only devices with regulated DC bus voltage
without other device on DC bus
at ULN_nenn to UR_DC_On
observe factors f Ta; f P_DC; HMV: without fs; without fout
observe factors f Ta; f P_DC
HMV: see also troubleshooting guide for E8025, F2817
HMV: see also troubleshooting guide for E2026, F2026; HCS: Depend
ing on parameter setting, see parameter description "P00114, Under
voltage threshold"

Fig.7-60:

HMV - Data of supply unit - DC bus

fP_DC_hi
fP_DC_lo

factor in range ULN>ULNnenn


factor in range ULNULNnenn

Fig.7-61:

Characteristic of DC bus continuous power PDC versus mains connec


tion voltage ULN

Braking Resistor
Data of built-in braking resistor
Description

Symbol

Unit

HMV02.1R-W0015

braking resistor continuous power1)

PBD

kW

0,30

braking resistor peak power at


UDC = 850 V2)

PBS

kW

33,00

ohm

16

ohm

17

nominal braking resistance


maximum braking resistance at
PBD

RDC_Bleed
er

RDC_Bleed
er

244/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Description
braking resistor switch-on thresh
old - mains voltage independent3)
braking resistor switch-on thresh
old - mains voltage dependent4)

Symbol

Unit

HMV02.1R-W0015

UR_DC_On_f

820

ULN x 1,41 + 80

R_DC_On_v

maximum allowed duty cycle at


Tcycl

EDrel

1,20

minimum allowed cycle time

Tcycl

134,00

maximum regenerative power to be


absorbed

WR_max

kWs

40,00

balancing factor for PBD (for parallel


operation at common DC bus)

cooling of internal braking resistor5)


1)
2)
3) 4)
5)

Fig.7-62:

observe derating factor f Ta; 0 kW when ext. braking resistor is used


0: no internal braking resistor; 0 kW when ext. braking resistor is used
factory setting; with HCS see parameter description "P-0-0833, Braking
resistor threshold" and "P-0-0860, Converter configuration"; with HMV
see X32
n: natural convection; f: forced cooling

HMV - Data of built-in braking resistor

Exemplary Data for Applications


General Information
This section contains

examples of allowed performance profiles

Performance Profiles
Performance Profiles of Regenera
tive Supply Units

The following profiles have been defined for regenerative supply units.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

245/315

IndraDrive M Supply Units

Profile
performance profile WZM_HS_KB_e

Explanation
The characteris
tic data of the
profile are used
to select infeed
ing and regener
ative supply
units.
Characteristic of
applications in
machine tools,
short-time oper
ation of the main
spindle.

performance profile WZM_HS_Fr_r

The characteris
tic data of the
profile are used
to select regen
erative supply
units.
Characteristic of
main spindles in
milling ma
chines.

performance profile WZM_SA_acc_r

The characteris
tic data of the
profile are used
to select regen
erative supply
units.
Characteristic of
servo drives at
machine tools.

246/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Profile
performance profile DRM_S1_acc_e

Explanation

The characteris
tic data of the
profile are used
to select infeed
ing and regener
ative supply
units.
Characteristic of
starting and op
eration at print
ing machines.

performance profile DRM_S1_acc_r

The characteris
tic data of the
profile are used
to select regen
erative supply
units.
Characteristic of
deceleration at
printing ma
chines.

performance profile UEL_P_e


The characteris
tic data of the
profile are used
to select infeed
ing and regener
ative supply
units.
Characteristic of
applications us
ing standard mo
tors in overload
operation.

Fig.7-63:

Definitions of performance profiles, regenerative supply units

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

247/315

IndraDrive M Supply Units


Examples of allowed performance profiles, supply units HMV....R
Description
DC bus power at ULN_nenn; t = 132 s;
T = 300 s; with mains choke1)
maximum DC bus power at
ULN_nenn; t = 132 s; T = 300 s; with
mains choke2)
DC bus power at ULN_nenn; t = 6 s;
t = 60 s; with mains choke3)
maximum DC bus power at
ULN_nenn; t = 6 s; t = 60 s; with mains
choke4)
DC bus power at ULN_nenn; t = 0.4 s;
T = 4 s; with mains choke5)
maximum DC bus power at
ULN_nenn; t = 0.4 s; T = 4 s; with
mains choke6)
DC bus power at ULN_nenn; t = 60 s;
T = 900 s; with mains choke7)
maximum DC bus power at
ULN_nenn; t = 60 s; T = 900 s; with
mains choke8)

Symbol
P
DC_base_14

P
DC_peak_14

P
DC_base_15

P
DC_peak_15

P
DC_base_16

P
DC_peak_16

P
DC_base_17

P
DC_peak_17

Unit

HMV02.1R-W0015

kW

kW

15,00

kW

3,00

kW

30,00

kW

kW

30,00

kW

9,00

kW

15,00

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 0,4 s;
T = 4 s; K = 2,5;
PDC_peak = PDC_max; with mains
choke9)

PDC_peak_1

kW

25,00

DC bus power at ULN_nenn;


Ta Ta_work; t = 0,4 s; T = 4 s;
K = 2,5; PDC_peak = PDC_max; with
mains choke10)

PDC_base_1

kW

10,00

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 2 s;
T = 20 s; K = 2,0; with mains
choke11)

PDC_peak_3

kW

22,00

DC bus power at ULN_nenn;


Ta Ta_work; t = 2 s; T = 20 s; K = 2,0; PDC_base_3
with mains choke12)

kW

11,00

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
T = 5 min; K = 1,5; with mains
choke13)

PDC_peak_4

kW

16,00

DC bus power at ULN_nenn;


Ta Ta_work; t = 60 s; T = 5 min;
K = 1,5; with mains choke14)

PDC_base_4

kW

10,60

248/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Description

Symbol

Unit

HMV02.1R-W0015

maximum DC bus power at


ULN_nenn; Ta Ta_work; t = 60 s;
T = 10 min; K = 1.1; with mains
choke15)

PDC_peak_5

kW

15,00

DC bus power at ULN_nenn;


Ta Ta_max; t = 60 s; T = 10 min;
K = 1,1; with mains choke16)

PDC_base_5

kW

13,60

1) 2) 4)
3)
5) 6) 8)
7)
9) 10) 11) 12)
13) 14) 15)
16)

Fig.7-64:

see definition profile WZM_HS_KB_e


see definition profile WZM_HS_Fr_r
see definition profile WZM_SA_acc_r
see definition profile DRM_S1_acc_r
see definition profile UEL_P_e

HMV....R - Examples of allowed performance profiles

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

249/315

IndraDrive M Supply Units

7.4.5

Connections and Interfaces

Overview
Overall Connection Diagram
Overall connection diagram with mains filter, mains choke, supply unit, power
section

HNS02
HNL02
HMV02
HMS02

Fig.7-65:

mains filter
mains choke
supply unit
power section

Overall connection diagram (mains filter, mains choke, supply unit, pow
er section)

250/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units


Overall connection diagram with mains filter, mains choke, supply unit, power
section

HNS02
HNL02
HMV02
HMS02

Fig.7-66:

mains filter
mains choke
supply unit
power section

Overall connection diagram (mains filter, mains choke, supply unit, pow
er section)

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

251/315

IndraDrive M Supply Units


Overall Connection Diagram of Supply Unit

Fig.7-67:

Connection diagram

252/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

IndraDrive M Supply Units

Arrangement of the Connection Points

XS1
X33
X32
X31
X2
X14
X1
1)
2)
3)
4)
5)

Fig.7-68:

shield connection for control lines


acknowledge messages of mains contactor
mains contactor control and DC bus short circuit (ZKS)
connection for messages
RS232
mains voltage synchronization
module bus
control panel
control voltage
DC bus
connection of equipment grounding conductor
mains connection

Connections HMV02.1R

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

253/315

IndraDrive M Supply Units

Description of the Connection Points


The connection points are described in detail in chapter 8 Functions and Elec
trical Connection Points , page 255.
Touch Guard

The touch guard is described in detail in chapter 9 Touch Guard at Devices ,


page 299.

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

255/315

Functions and Electrical Connection Points

Functions and Electrical Connection Points

8.1

Overview of Functions
The table below shows the most important hardware functions which the com
ponents provide.

Functions

Available at component

Connec
tion point

Description /

X1

Information on the status of the drive controllers


is exchanged via the module bus.

properties

General
data exchange via module bus HMS01; HMS02; HMV01;

HMV02; HCS021) ; HCS03;


HCS04

commissioning and service in HMV01; HMV02; control sec X2


terface
tions

serial interface RS232

24V supply
integrated control voltage sup HCS02.1E--NxxV (optional ply
equipment)

24V supply is generated from the DC bus via a


switching power supply unit.
UDC > 200V

HCS03.1E--xxxV

24V supply is generated from the DC bus via a


switching power supply unit.
UDC > 300V

plug with screw flange con


nection

HCS02

X13

screw connection

HMS01; HMS02; HMV01;


HMV02; HCS03; HCS04

+24V; 0V

Provides the option to loop through the supply


via contact bars.

message ready for operation


(Bb)

HMV01; HMV02

X31

Floating contact which shows the status of the


drive controller.

message DC bus (UD)

HMV01; HMV02

X31

Floating contact which shows the status of the DC


bus of the supply unit.

message warning (WARN)

HMV01; HMV02

X31

Floating contact which shows the status of the


drive controller.

X14

used for synchronizing regeneration stage with


supply mains at X3

Message contacts

Mains input
for supply with mains voltage, HMV01.1R
infeeding and regenerative HMV02.1R
for supply with mains voltage, HMV01.1E
infeeding HCS02.1E
HCS03.1E
HCS04.1E
input mains voltage synchro HMV01.1R
nization HMV02.1R

1)

not available for HCS02.1E-W0012

256/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


Functions

Available at component

plug with screw flange con HCS02.1E-W00120070


nection HCS03.1E-W0070
screw connection

HCS03.1E-W01000210

Connec
tion point

Description /
properties

X3
X3

Mains contactor and its control


integrated mains contactor

HMV012)

external mains contactor

HCS02; HCS03; HCS041)


HMV01.1R-W0120
HMV02.1R

contact for controlling the ex HMV01.1R-W0120


ternal mains contactor

X34

input for N/O contact (EIN)

HMV013)

X32

connection for ON switch of mains connection

input for N/C contact (AUS)

HMV014)

X32

connection for OFF switch of mains connection

X33

1 N/O contact and 1 N/C contact

integrated feedback contacts HMV with integrated mains


contactor
inputs for feedback contacts

HMV without integrated mains X33


contactor

for 1 N/O contact and 1 N/C contact

HMV; HMS; HMD; HCS5)

Provides the option to loop through the supply


via contact bars.

DC bus functions
connection for DC bus

terminal
block
L+; L-

controlled DC bus voltage

HMV01.1R
HMV02.1R

input DC bus short circuit


(ZKS)

HMV01.1E

X32

Input via which the ZKS stage can be controlled.

X9

connection for HLR braking resistors

X32

This input determines how the switch-on thresh


old of the built-in braking resistor is generated.

HLB01.1C, D

Braking resistor
built-in braking resistor

HCS02; HMV01; HMV02

connection external braking


resistor

HCS02.1E-W00540070

braking resistor switch-on


threshold

HMV01.1E

HCS03.1E-W00700210

braking resistor switch-on


HCS02.1E-Wxxxx-A-03threshold active, in spite of
NxxV
failure of external 24V supply HCS03.1E-Wxxxx-A-05-xxBV

supply from DC bus via integrated switching pow


er supply unit

Motor output

2)

not available for HMV01.1R-W0120

3)

not available for HMV01.1R-W0120

4)

not available for HMV01.1R-W0120

5)

not available for HCS02.1E-W0012

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

257/315

Functions and Electrical Connection Points


Functions

Available at component

Connec
tion point

Description /

input motor temperature mon HCS; HMS; HMD


itoring

X6

input (per axis) used to connect sensor of motor


temperature evaluation

output for controlling motor


holding brake via electronic
contact

HMS01; HMD01; HCS03;


HCS041)

X6

output (per axis) via which motor holding brake


can be controlled

output for controlling motor


holding brake via electrome
chanic contact

HCS02; HMS02

X6

output (per axis) via which motor holding brake


can be controlled

plug with screw flange

HCS02.1E-W00120070

X5

properties

HCS03.1E-W0070
screw connection

HCS03.1E-W0100W0210

X5

HMV01
Others
supply external blower unit
HAB01

HMV01.1R-W0120

X13

blower control depending on


cooling system load

HCS02.1E-Wxxxx-A-03-LxxN HCS03.1E-Wxxxx-A-05-LxxV

system-internal connection
reduces noise development in operation under
partial load

mechanical receptacle for


HCS03.1E-W0070210
braking resistor HLR01 at the
top

allows ventilating braking resistor HLR in outlet


air of converter

mechanical receptacle for


HCS03.1E-W0070210
mains filter HNK01 and motor
filter HMF01 at the bottom

allows ventilating mains filter HNK01 and motor


filter HMF01 in supply air of converter

Fig.8-1:

8.2

Functions

Electrical Connection Points Overview

Connection point
X1

At component

Brief description

HCS03; HCS04; HMS01; HMS02; HMD01;


HMV01; HMV02; HLB01

module bus

HCS026)

connection in drive system

X2

HMV01; HMV02

commissioning and service interface

X3

HCS02; HCS03; HCS04; HMV01; HMV02

mains connection

X5

HMS01; HMS02; HCS02; HCS03; HCS04

inverter output
connection to motor

X5.1

HMD01

inverter output

X5.2
X6

connection to motor
HMS01; HMS02; HCS02; HCS03; HCS04

connection for temperature monitoring and hold


ing brake
connection to motor

6)

not available at HCS02.1E-W0012

258/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


Connection point
X6.1

At component

Brief description

HMD01

connection for temperature monitoring and hold


ing brake

X6.2

connection to motor

X9

HCS02.1E-W0054

connection external braking resistor

HCS02.1E-W0070
HCS03.1E-Wxxxx-xxBx
X13

HCS02.1E

control voltage (24V, 0V)

X13

HMV01.1R-W0120

system-internal connection
supply of external blower unit HAB01

X14

HMV01.1R

mains voltage synchronization

HMV02.1R
HNS02
X31

HMV01; HMV02; HLB01

messages Bb1, UD, WARN


UD not available for HLB01

X32

HMV01; HMV02

mains contactor control and DC bus short circuit


(ZKS)

X32

HLB01

DC bus short circuit control, clear errors, braking


resistor switch-on threshold

X33

HMV01; HMV02

acknowledge messages of mains contactor

X34

HMV01.1R-W0120

contact for controlling the external mains contac


tor

HNS02

converter from D-Sub to terminal blocks for con


nections optional safety technology modules L1,
S1 at control sections

HMV01; HMV02; HMS01; HMS02; HMD01;


HCS03

control voltage supply

HMV01; HMV02; HMS01; HMS02; HMD01;


HCS03

DC bus connection

X41.1; X41.2

+24V; 0V
L+; L-

HCS027)
XS1

HCS02

connections integrated in terminal block


connections integrated in terminal block
shield connection, control lines
cable shields

ground connection

all

connection of housing to ground potential

all

equipment grounding conductor connection of


the component

Fig.8-2:

8.3

Electrical connection points overview

X1, Module Bus


Function, Pin Assignment

The module bus is an internal system connection used for data exchange be
tween the drive controllers.

7)

not available at HCS02.1E-W0012

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

259/315

Functions and Electrical Connection Points


View

Notes on Installation

Fig.8-3:

Identification

Function

X1 in

to plug in module bus connector

X1 out

passes module bus connection to


neighboring drive controller

X1, module bus

Keep ribbon cable in parking position, when neighboring device is not connec
ted

8.4

X2, Serial Interface (RS232)

8.4.1

General Information
The serial interface (RS232) is required for programming, parameterization and
diagnosis during commissioning and servicing.
Connec
tion point

Type

No. of
poles

Stranded
wire

Description

Figure

[mm]
X2

MiniDin,
female
(device)

Fig.8-4:
Pin Assignment

n.c.
Features

0,250,5

serial interface

Connections

Pin

Signal

RTS

request to send

CTS

clear to send

TxD

transmit data

GND

reference potential

RxD

receive data

Vcc

supply voltage

n.c.

n.c.

n.c.

n.c.

Fig.8-5:
Feature

Function

not connected

Pin assignment of serial interface


Unit
Min.

number of nodes
allowed cable length
transmission rates

Typ.

Max.
1

m
kBaud

15
9,6

115

260/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


Feature

Unit

connection

Typ.

Max.

galvanically connected to control section


supply

allowed voltage difference be


tween reference potentials of
control section and data end de
vice

Fig.8-6:

Min.

Features of serial interface

The accessory HAS05.1-005 makes available a converter from


RS232 to RS485. For its description, see chapter Accessories of
Project Planning Manual for Rexroth IndraDrive, Drive System.

8.4.2

Connection Diagrams Serial Interface to PC

Serial Interface to PC With 9-Pin


SUB-D

Fig.8-7:

(KA000041) Connection of serial interface to PC with 9-pin D-SUB

For direct connection to the serial interface, use our cable


IKB0041 .
Serial Interface to PC With 25-Pin
SUB-D

Fig.8-8:

(KA100001) Connection of serial interface to PC with 25-pin D-SUB

8.5

X3, Mains Connection

8.5.1

Important Notes
Lethal electric shock caused by live parts with more than 50 V!
Exclusively operate the drive controller with plugged on connector!

DANGER

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

261/315

Functions and Electrical Connection Points


Notes on Installation

The indicated connection cross sections are the cross sections which can be
connected. Dimension the required cross section of the connecting lines ac
cording to the determined phase current ILN.

Damage to the drive controller


You have to provide strain relief for the terminal connectors of the drive con
troller in the control cabinet or use the optionally available connection accessory
HAS02.

CAUTION

8.5.2

X3, Mains Connection HMV02.1R-W0015

View

Identifica
tion

Function 3-phase operation

L1

connection to supply mains (L1)

L2

connection to supply mains (L2)

L3

connection to supply mains (L3)


connection of equipment grounding conductor of drive con
troller

Screw connection at connector

Unit

Min.

Max.

tightening torque

Nm

1,5

1,7

connection cable

mm2

1,5

stranded wire

AWG

16

10

occurring current load and minimum required


connection cross section

see Technical Data of device used (IL_cont, IL_max and ALN)

occurring current load

see Technical Data of device used (ULN)

Fig.8-9:

Function, pin assignment, properties

262/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

8.5.3

X3, Mains Connection HCS02.1E-W0012, -W0028

View

Identifica
tion
L1

Function 3-phase operation

Function 1-phase operation

connection to supply mains (L1)

L2

connection to supply mains


(L2)

connection to neutral conduc


tor supply mains

L3

connection to supply mains


(L3)

n.c.

connection of equipment grounding conductor of drive con


troller

Screw connection at connector

Unit

Min.

Max.

tightening torque

Nm

0,5

0,6

mm2 /
AWG

1,5 / 16

4 / 10

connection cross section


stranded wire
occurring current load and minimum required
connection cross section

see Technical Data of device used (IL_cont, IL_max and ALN)

occurring voltage load

see Technical Data of device used (ULN)

Fig.8-10:

8.5.4

Function, pin assignment, properties

X3, Mains Connection HCS02.1E-W0054, -W0070 and HCS03.1EW0070

View

Identifica
tion
L1

Function 3-phase operation

Function 1-phase operation 1)

connection to supply mains (L1)

L2

connection to supply mains


(L2)

connection to neutral conduc


tor supply mains

L3

connection to supply mains


(L3)

n.c.

connection of equipment grounding conductor of drive con


troller

Screw connection at connector

Unit

Min.

Max.

tightening torque

Nm

1,5

1,7

mm2

1,5 / 16

16 / 6

connection cross section

/
AWG

stranded wire
occurring current load and minimum required
connection cross section

see Technical Data of device used (IL_cont, IL_max and ALN)

occurring voltage load

see Technical Data of device used (ULN)

1)

Fig.8-11:

only allowed with HCS02.1E drive controllers

Function, pin assignment, properties

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

263/315

Functions and Electrical Connection Points

8.5.5

X3, Mains Connection HCS03.1E-W0100..0150 and HMV01.1RW0018..0065; HMV01.1E-W0030..0075

View

Identifica
tion

Function

L1

connection to supply mains (L1)

L2

connection to supply mains (L2)

L3

connection to supply mains (L3)


connection of equipment grounding conductor of drive con
troller

Terminal block

Unit

Min.

Max.

screw thread

M6

tightening torque

Nm

connection cables

mm2

stranded wire with ring cable lug

5,5

6,5
116; 125; 135; 150
225; 235; 250
216 with accessories

AWG

16; 14; 12; 11


24; 22; 21
26 with accessories

occurring current load and minimum required


connection cross section

see Technical Data of device used (IL_cont, IL_max and ALN)

occurring voltage load

see Technical Data of device used (ULN)

Fig.8-12:

Function, pin assignment, properties

264/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

8.5.6

X3, Mains Connection HCS03.1E-W0210

View

Identifica
tion

Function

L1

connection to supply mains (L1)

L2

connection to supply mains (L2)

L3

connection to supply mains (L3)


connection of equipment grounding conductor of drive con
troller

Terminal block

Unit

Min.

Max.

screw thread

M10

tightening torque

Nm

connection cables

mm2

16

20
116; 125; 135; 150

stranded wire with ring cable lug

225; 235; 250


216 with accessories
AWG

16; 14; 12; 11


24; 22; 21
26 with accessories

occurring current load and minimum required


connection cross section

see Technical Data of device used (IL_cont, IL_max and ALN)

occurring voltage load

see Technical Data of device used (ULN)

Fig.8-13:

8.5.7

Function, pin assignment, properties

X3, Mains Connection HMV01.1E-W0120 and HMV01.1R-W0120


View

Identification

Function 3-phase operation

L1

connection to supply mains (L1)

L2

connection to supply mains (L2)

L3

connection to supply mains (L3)


connection of equipment grounding conductor of
drive controller

Terminal block
screw thread

Unit

Min.

Max.
M10

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

265/315

Functions and Electrical Connection Points


View

Identification

tightening torque

Nm

connection cable

mm2

Function 3-phase operation


16

20

116; 125; 135; 150; 170; 1120

stranded wire with ring cable lug

216 (with different angles)


225; 235; 250; 270; 2120
AWG

16; 14; 12; 11; 11/0; 12/0; 14/0


26 (with different angles)
24; 22; 21; 21/0; 22/0; 24/0

occurring current load and minimum required


connection cross section

see Technical Data of device used (IL_cont, IL_max


and ALN)

occurring current load

see Technical Data of device used (ULN)

Fig.8-14:

8.5.8

X3, Mains connection

X3, Mains Connection HCS04.1E-W0500 (Preliminary)


View

Identification

Function 3-phase operation

L1

connection to supply mains (L1)

L2

connection to supply mains (L2)

L3

connection to supply mains (L3)


connection of equipment grounding conductor of
drive controller

Terminal block

Unit

Min.

screw thread

Max.

through-hole for M10

tightening torque

Nm

connection cross section

mm2

stranded wire with ring cable lug

16

20

1x16; 1x25; 1x35; 1x50; 1x70; 1x120


2x16; 2x25; 2x35; 2x50; 2x70; 2x120

AWG

1x6; 1x4; 1x2; 1x1; 1x1/0; 1x2/0; 1x4/0


2x6; 2x4; 2x2; 2x1; 2x1/0; 2x2/0; 2x4/0

occurring current load and minimum required


connection cross section

see Technical Data of device used (IL_cont, IL_max


and ALN)

occurring voltage load

see Technical Data of device used (ULN)

Fig.8-15:

X3, mains connection

266/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

8.6

X5, Motor Connection

8.6.1

Important Notes
Lethal electric shock caused by live parts with more than 50 V!
Exclusively operate the drive controller with plugged on connector!

DANGER
Damage to the drive controller
CAUTION
Notes on Installation

You have to provide strain relief for the terminal connectors of the drive con
troller in the control cabinet or use the optionally available connection accessory
HAS02.
The connection cross section data refer to the line cross sections which can be
connected. Dimension the required cross section of the connecting lines ac
cording to the occurring current load by the motor which is used.

Damage to the drive controller


CAUTION

Coding of the Connectors

You have to provide strain relief for the terminal connectors of the drive con
troller in the control cabinet or use the optionally available connection accessory
HAS02.

For optimum shield contact of the motor power cable, use our
accessory HAS02, where possible.

For the connection between drive controller and motor use our
ready-made motor power cables, where possible (see docu
mentation Rexroth Connection Cables - Selection Data).

When using NFD03.1 mains filters, the maximum allowed con


ductor cross section is limited to 4 mm2.

For selecting the motor cables, observe the information con


tained in the section Connection Cables to Motor in the
documentation Rexroth IndraDrive Drive System - Project
Planning Manual .

At the HMD power sections with two inverter outputs, the outputs
have been coded, i.e. provided with a coding section. This avoids
accidentally interchanging the two cables.

Coding

X5.1: coding section at pin 2

X5.2: coding section at pin 1


For ready-made Rexroth motor power cables, you therefore have
to change the coding of the male connector at the motor power ca
ble for X5.2, i.e. put the coding section at the male connector (not
at the female connector at the drive controller) from pin 1 to pin 2.
For X5.1, you do not need to change the coding of the male con
nector at the motor power cable.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

267/315

Functions and Electrical Connection Points

Fig.8-16:

8.6.2

Coding of X5.1 and X5.2

X5, Motor Connection HCS02.1E-W0012, -W0028 and HMS01.1NW0020, -W0036 and HMD01.1N-W0012..0036 and HMS02.1N-W0028

View

Identifica
tion

Function

A1

for power connection U1 at motor

A2

for power connection V1 at motor

A3

for power connection W1 at motor


for equipment grounding conductor of motor

Screw connection at connector

Unit

Min.

Max.

tightening torque

Nm

0,5

0,6

connection cable

mm2

1,5

stranded wire

AWG

16

10

occurring current load and minimum required


connection cross section

see Technical Data of device used (Iout)

occurring voltage load

see Technical Data of device used (Uout)

short circuit protection

A1, A2, A3 against each other and each of them against


ground

Fig.8-17:

Function, pin assignment, properties

268/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

8.6.3

X5, Motor Connection HCS02.1E-W0054, -W0070 and HCS03.1EW0070 and HMS01.1N-W0054, -W0070 and HMS02.1N-W0054

View

Identifica
tion

Function

A1

for power connection U1 at motor

A2

for power connection V1 at motor

A3

for power connection W1 at motor


for equipment grounding conductor of motor

Screw connection at connector

Unit

Min.

Max.

tightening torque

Nm

1,5

1,7

connection cable

mm2

1,5

16

stranded wire

AWG

16

occurring current load and minimum required


connection cross section

see Technical Data of device used (Iout)

occurring voltage load

see Technical Data of device used (Uout)

short circuit protection

A1, A2, A3 against each other and each of them against


ground

Fig.8-18:

8.6.4

Function, pin assignment, properties

X5, Motor Connection HMS01.1N-W0110

View

Identifica
tion

Function

A1

for power connection U1 at motor

A2

for power connection V1 at motor

A3

for power connection W1 at motor


for equipment grounding conductor of motor

Terminal block

Unit

Min.

screw thread
tightening torque

Max.
M6

Nm

5,5

6,5

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

269/315

Functions and Electrical Connection Points


connection cable

116; 125; 135

mm2

stranded wire with ring cable lug

216; 225; 235


AWG

16; 14; 12; 11


26; 24; 22; 21

occurring current load and minimum required


connection cross section

see Technical Data of device used (Iout)

occurring voltage load

see Technical Data of device used (Uout)

short circuit protection

A1, A2, A3 against each other and each of them against


ground

Fig.8-19:

8.6.5

Function, pin assignment, properties

X5, Motor Connection HCS03.1E-W0100..0150 and HMS01.1NW0150..0210

View

Identifica
tion

Function

A1

for power connection U1 at motor

A2

for power connection V1 at motor

A3

for power connection W1 at motor


for equipment grounding conductor of motor

Terminal block

Unit

Min.

Max.

screw thread

M6

tightening torque

Nm

connection cables

mm2

stranded wire with ring cable lug

5,5

6,5
116; 125; 135; 150
225; 235; 250
216 with accessories

AWG

16; 14; 12; 11


24; 22; 21
26 with accessories

occurring current load and minimum required


connection cross section

see Technical Data of device used (IL_cont, IL_max and ALN)

occurring voltage load

see Technical Data of device used (ULN)

short circuit protection

A1, A2, A3 against each other and each of them against


ground

Fig.8-20:

Function, pin assignment, properties

270/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

8.6.6

X5, Motor Connection HCS03.1E-W0210

View

Identifica
tion

Function

A1

for power connection U1 at motor

A2

for power connection V1 at motor

A3

for power connection W1 at motor


for equipment grounding conductor of motor

Terminal block

Unit

Min.

Max.

screw thread

M10

tightening torque

Nm

connection cables

mm2

16

20
116; 125; 135; 150

stranded wire with ring cable lug

225; 235; 250


216 with accessories
AWG

16; 14; 12; 11


24; 22; 21
26 with accessories

occurring current load and minimum required


connection cross section

see Technical Data of device used (IL_cont, IL_max and ALN)

occurring voltage load

see Technical Data of device used (ULN)

short circuit protection

A1, A2, A3 against each other and each of them against


ground

Fig.8-21:

8.6.7

Function, pin assignment, properties

X5, Motor Connection HMS01.1N-W0350 (Preliminary)


View

Identification

Function

A1

for power connection U1 at motor

A2

for power connection V1 at motor

A3

for power connection W1 at motor


for equipment grounding conductor of motor

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

271/315

Functions and Electrical Connection Points


View

Identification

Terminal block

Unit

Function

Min.

screw thread

Max.
M10

tightening torque

Nm

connection cables

mm2

stranded wire with ring cable lug

16

20

116; 125; 135; 150; 170; 1120


216, 225; 235; 250; 270; 2120

AWG

16; 14; 12; 11; 11/0; 12/0; 14/0


26; 24; 22; 21; 21/0; 22/0; 24/0

occurring current load and minimum required


connection cross section

see Technical Data of device used (IL_cont, IL_max


and ALN)

occurring voltage load

see Technical Data of device used (ULN)

short circuit protection

A1, A2, A3 against each other and each of them


against ground

Fig.8-22:

8.6.8

X5, motor connection

X5, Motor Connection HCS04.1E-W0500 (Preliminary)


View

Identification

Function

A1

for power connection U1 at motor

A2

for power connection V1 at motor

A3

for power connection W1 at motor


for equipment grounding conductor of motor

Terminal block

Unit

Min.

screw thread

Max.

through-hole for M10

tightening torque

Nm

connection cables

mm2

stranded wire with ring cable lug

16

20

116; 125; 135; 150; 170; 1120


216; 225; 235; 250; 270; 2120

AWG

16; 14; 12; 11; 11/0; 12/0; 14/0


26; 24; 22; 21; 21/0; 22/0; 24/0

occurring current load and minimum required


connection cross section

see Technical Data of device used (IL_cont, IL_max


and ALN)

occurring voltage load

see Technical Data of device used (ULN)

Fig.8-23:

X5, motor connection

272/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

8.7

X6, Motor Temperature Monitoring and Motor Holding Brake

8.7.1

Important Notes
Lethal electric shock caused by live parts with more than 50 V!
Exclusively operate the drive controller with plugged on connector!

DANGER
Dangerous movements! Danger to personnel from falling or dropping
axes!
The standard motor holding brake provided or an external motor holding brake
controlled directly by the drive controller are not sufficient on their own to guar
antee the safety of personnel!

DANGER

Personnel safety must be achieved using higher-ranking, fail-safe procedures:

Function

Dangerous areas should be blocked off with protective fences or grids

Additionally secure vertical axes against falling or dropping after switching


off the motor power by, for example:

mechanically securing the vertical axes

providing external braking/catching/clamping mechanisms

ensuring sufficient equilibration of the vertical axes

The connection point X6 contains the connections for monitoring the motor
temperature and for controlling the motor holding brake.
Via an integrated contact element, the power section switches the
voltage of the 24V supply (connection X13 at HCS02 power sec
tions) to the output for controlling the motor holding brake.

Notes on Installation

Make sure the voltage supply for the motor holding at the motor
brake is sufficient. You have to take into account that voltage drops
on the supply line. Use connecting lines with the highest possible
cross section of the single strands.
An external contact element is required, if motor holding brakes with
higher currents than the allowed current load are to be supplied at
X6.

Coding of the Connectors

At the HMD power sections with two inverter outputs, the outputs
have been coded, i.e. provided with a coding section. This avoids
accidentally interchanging the two cables.

Coding

X6.1: coding section at pin 4

X6.2: coding section at pin 1


For ready-made Rexroth motor power cables, you therefore have
to code the male connector at the motor power cable accordingly
for X6.1 and X6.2:

for connector X6.1: cut off plastic pin 4 at connector

for connector X6.2: cut off plastic pin 1 at connector

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

273/315

Functions and Electrical Connection Points

Fig.8-24:

8.7.2

Coding of X6.1 and X6.2

Connection Point

View

Connec
tion

Signal name

Function

MotTemp+

MotTemp-

input motor temperature eval


uation

+24V

0V

Spring terminal (connector)

Unit

Min.

Max.

connection cable solid wire

mm2

0,5

1,5

connection cable stranded wire

mm2

0,5

1,5

AWG

20

16

HCS02.1E-W0012; W0028; W0054; W0070

HCS03.1E-W0070; W0100; W0150; W0210

HCS04.1E

tbd

HMS01.1N-W0020; W0036

1,6

HMS01.1N-W0054; W0070

output for controlling the mo


tor holding brake

current load capacity X6.3, X6.4:

274/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


HMS01.1N-W0110; W0150; W0210

2,5

HMS02.1N-W0028; W0054

HMD01.1N-W0012; W0020; W0036

1.5 per axis

ms

50

time constant of load


number of switching actions at max. time con
stant of load
switching frequency

250.000
Hz

0,5

short circuit protection

X6.3 against X6.4 (output for controlling the motor holding


brake)

overload protection

X6.3 against X6.4 (output for controlling the motor holding


brake)

integrated contact element for controlling the mo


tor holding brake:
HCS02.1E

electromechanical contact

HMS02.1N
HCS03.1E

electronic contact

HCS04.1E
HMS01.1N
HMD01.1N

Fig.8-25:

Function, pin assignment

Fig.8-26:

Motor temperature monitoring and motor holding brake connection

Connection Diagram

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

275/315

Functions and Electrical Connection Points

8.8

X9, External Braking Resistor

8.8.1

Important Notes
Lethal electric shock caused by live parts with more than 50 V!
Exclusively operate the drive controller with plugged on connector!

DANGER
Keep in mind that you have to parameterize the external braking
resistor in the drive controller to protect the drive controller and the
braking resistor against overload.
See also Parameter Description of the firmware used
P-0-0860, Converter configuration and
P-0-0858, Data of external braking resistor

8.8.2

X9, External Braking Resistor HCS02.1E-W0054, -W0070


Function, Pin Assignment

X9 is used to connect an external braking resistor which is controlled via the


internal switch.
For HCS02 devices, the connection X9 is contained in all designs,
except for-W0012 and -W0028.
For HCS03 devices, the connection X9 is contained in the design xxBV.

View

Connec
tion

Signal name

Function

n.s.

connection braking resistor

n.s.

connection braking resistor

Screw terminal (connector)

Unit

Min.

Max.

connecting line

mm2

2,5

stranded wire

AWG

14

10

Nm

1,5

1,7

tightening torque
current load

peak value: 30
r.m.s. value: 15

voltage load

short circuit protection

to be ensured by means of appropriate fusing elements in the


mains connection at X3
n.s.

Fig.8-27:
Notes on Installation

n.s.

not specified

Function, pin assignment

Maximum allowed line length to external braking resistor: 5 m


Twist unshielded lines.

276/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

Danger by insufficient installation!


Protect the lines with the appropriate fusing elements in the supply feeder.
For the connecting lines at X9, use at least the cross section of the lines for
mains connection at X3.

CAUTION

8.8.3

X9, Externals Braking Resistor HCS03.1E-W0070...0210


Function, Pin Assignment

X9 is used to connect an external braking resistor which is controlled via the


internal switch.
For HCS03 devices, the connection X9 is contained in the design xxBV.

View

Screw terminal (connector)

Connec
tion

Signal name

Function

n.s.

connection braking resistor

n.s.

connection braking resistor

Unit

Min.

Max.

HCS03.1E-W0070
connecting line

mm2

16

stranded wire

AWG

tightening torque

Nm

1,5

1,7

HCS03.1E-W0100, -W0150
connecting line

mm2

25

stranded wire

AWG

tightening torque

Nm

2,0

2,5

HCS03.1E-W0210
connecting line

mm2

50

stranded wire

AWG

tightening torque

Nm

8,0

9,0

HCS03.1E
voltage load

short circuit protection

to be ensured by means of appropriate fusing elements in the


mains connection at X3
n.s.

Fig.8-28:
Notes on Installation

n.s.

not specified

Function, pin assignment

Maximum allowed line length to external braking resistor: 5 m


Twist unshielded lines.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

277/315

Functions and Electrical Connection Points

Danger by insufficient installation!


Protect the lines with the appropriate fusing elements in the supply feeder.
For the connecting lines at X9, use at least the cross section of the lines for
mains connection at X3.

CAUTION

8.9

X13, Control Voltage (24V, 0V)


Function, Pin Assignment

The external 24V supply is applied via connection point X13 for

the power section of the drive controller

the brake control via X6

the control section of the drive controller with the optional modules, except
for such optional modules (e.g. safety technology S1) which require their
own power supply.

Assignment

Connec
tion

Signal name

Function

+24V

+24V

0V

0V

Spring terminal (connector)

Unit

Min.

Max.

connection cross section solid wire

mm2

1,0

1,5

connection cross section stranded wire

mm2

1,0

1,5

connection cross section

AWG

18

16

power supply and looping


through
reference potential for power
supply and looping through

power consumption

see PN3 (see index entry with reference to the corresponding


page)

voltage load capacity

see UN3 (see index entry with reference to the corresponding


page)

current load capacity at loop-through contact

polarity reversal protection

within the allowed voltage range by internal protective diode

Fig.8-29:
Notes on Installation

Function, pin assignment, properties

Requirements on the connection to the 24V supply:

minimum cross section: 1 mm2

maximum allowed inductance: 100 H (2 twisted single strands, 75 m


long)

parallel line routing where possible

The control voltage supply is routed to the connection X13 from above.

278/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

Fig.8-30:

lines to control voltage supply

Control voltage supply at X13

The input 0V is connected in conductive form with the housing po


tential. It is therefore impossible to use an insulation monitor at
+24V and 0V against housing.

8.10

X13, Supply External Blower Unit HAB01

8.10.1

General Information
Description

Via this connection, the external blower unit (HAB01) of HMV01.1RW0120


devices is supplied with voltage (24V, 0V). The connection is situated at the
bottom of the device (see figure below).

Risk of damage by overheating!


CAUTION

Always operate HMV01.1R-W0120 supply units with the external blower unit
HAB01.

Do not operate any other loads at connection X13.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

279/315

Functions and Electrical Connection Points

Function, Pin Assignment

Fig.8-31:
Connection

Fig.8-32:

Connection at the bottom of the device


Signal name
1

24V

0V

Function, pin assignment

Function
power supply for external
blower unit HAB01

280/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

8.11

X14, Mains Voltage Synchronization

8.11.1

Connection Point
Description

Function, Pin Assignment

Technical Properties

This connection point only exists for regenerative supply units. The connection
point is used to connect the mains voltage for mains voltage synchronization
and for preloading the DC bus.
View

Fig.8-33:
Data

Connec
tion

Function

mains connection
phase L3 before
choke

max. 530 V current load


max. 5 A

mains connection
phase L2 before
choke

max. 530 V current load


max. 5 A

mains connection
phase L1 before
choke

max. 530 V current load


max. 5 A

Function, pin assignment


Unit

Level

Min. re
quired

number of poles

Typ.

Max. al
lowed

type

STECK - LE 7,62 M PC 4,0 / 3G

design

male connector at device

connection cable solid wire

mm2

1,5

connection cable stranded wire

mm2

1,5

2,5

AWG

14

12

Nm

0,5

0,6

tightening torque

Fig.8-34:

8.11.2

Note

Technical properties

Mains Synchronization HMV01


The synchronizing voltage has to be picked off before the mains choke and
after the mains filter. Power voltage and synchronizing voltage connection have
to be in phase (see figure).
The synchronizing voltage has to be connected to the input for mains voltage
synchronization (X14) of the supply unit.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

281/315

Functions and Electrical Connection Points

1)
2)
3)
4)

for fusing of connection X14 see note below


in-phase connection required
mains choke
mains filter

Fig.8-35:

Synchronizing voltage HMV01.1R

Install slow 5 A fuses in the supply line to connection X14.


Connect the connections X3 and X14 in phase:

8.11.3

X3.L1 in phase with X14.1

X3.L2 in phase with X14.2

X3.L3 in phase with X14.3

Mains Synchronization HMV02


For mains synchronization, the output X14 of the HNS02 mains filter has to be
connected to the input for mains voltage synchronization X14 of HMV02.1R.

282/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

Fig.8-36:

8.12

Synchronizing voltage HMV02.1R

X31, Messages Bb1, UD, WARN


View

Function, Pin Assignment

Fig.8-37:

View

The connection point X31 provides message signals on the status of the supply
unit. The messages have been designed as floating contacts.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

283/315

Functions and Electrical Connection Points


Pin assignment

Connec
tion

Signal
name

Function

Bb1_2

N/O contact signals readiness for


connecting the external mains
contactor

Bb1_1

Closed with:
readiness for operation of supply
unit
Open with:

UD_2
UD_1

error messages F2800 to


F2899

error messages F8069 and


F8070

warnings E2800 to E2899

N/O contact signals status of DC


bus voltage UDC
Closed with:
DC bus voltage in specified range

WARN_2
WARN_1

Fig.8-38:

N/C contact signals warning


states
Open with:

overload at integrated brak


ing resistor

overtemperature at supply
unit

Function, pin assignment

Include the Bb1 contact in the control circuit for mains connection.
When Bb1 contact opens, the mains contactor must interrupt the
power supply.
See also chapter Control Circuits for the Mains Connection in the
documentation "Rexroth IndraDrive - Drive System - Project Plan
ning Manual".
Technical Properties

Data

Unit

Min.

number of poles

Typ.

Max.

type

spring terminal

design

pins at device

connection cable solid wire

mm2

0,5

1,5

connection cable stranded wire

mm2

0,5

1,5

AWG

20

16

current load capacity

voltage load capacity

DC30

minimum load of contacts

mA

10

284/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


Data

Unit

contact resistance at minimum


load

Min.

8.13

Fig.8-39:

106

Technical properties

For the application prototypes of the supply units, the WARN con
tact had been realized as N/O contact. As of the following hardware
indices (HWIs), the WARN contact is realized as N/C contact:

HMV01.1E-W0030: as of HWI -14

HMV01.1E-W0075: as of HWI -14

HMV01.1E-W0120: as of HWI -15

HMV01.1R-W0018: as of HWI -17

HMV01.1R-W0045: as of HWI -17

HMV01.1R-W0065: as of HWI -18

X32, Mains Contactor Control and DC Bus Short Circuit


View

Function, Pin Assignment

Max.

mOhm

number of mechanical switching


cycles
Notes on Installation

Typ.

Fig.8-40:

View

Is used to connect the signals for controlling

the mains contactor

the ZKS device (ZKS = DC bus short circuit)

the braking resistor switch-on threshold

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

285/315

Functions and Electrical Connection Points


Pin assignment

Connec
tion

Signal
name

Function

24V_IF

0V

Supply of circuits for DC bus short


circuit and mains contactor con
trol

24V

Output (24 V)
Connected to connection X32.3,
it is used to switch the braking re
sistor switch-on threshold

braking re Input at HMV01.1E:


sistor

connected to 24 V (X32.2):
switch-on
activates fixed threshold
threshold
(independent of mains volt
age)

not connected: activates


variable threshold (depend
ing on mains voltage)

Switch-on thresholds: see Tech


nical Data, table Data of integra
ted braking resistor

EIN2

EIN1

HMV01.1E

HMV01.1R

HMV02.1R

Connection for N/O contact to


control the mains contactor
(switch-on)
The input is edge-controlled

Fig.8-41:

AUS2

AUS1

ZKS

Connection for N/C contact to


control the mains contactor
(switch-off)
Controls the ZKS device:

not connected: ZKS active

connected to 24 V: ZKS not


active

Connection point X32

Include the Bb1 contact in the control circuit for mains connection.
When Bb1 contact opens, the mains contactor must interrupt the
power supply.
See also chapter Control Circuits for the Mains Connection in the
documentation Rexroth IndraDrive - Drive System - Project Plan
ning Manual.
Technical Properties

Data
number of poles

Unit

Min.

Typ.
9

type

spring terminal

design

pins at device

Max.

286/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


Data

Unit

Min.

connection cable solid wire

mm2

0,5

1,5

connection cable stranded wire

mm2

0,5

1,5

AWG

20

16

current consumption (X32.9,


X32.1)

voltage load capacity

Fig.8-42:

8.14

Typ.

Max.

0,1
DC30

Technical properties

X33, Acknowledge Messages of Mains Contactor


View

Function, Pin Assignment

Fig.8-43:

View

The function of connection point X33 depends on the supply unit:


1.

Supply units with integrated mains contactor (HMV01.1, except for


HMV01.1R-W0120; HMV02.1): Provides message signals on the status
of the integrated mains contactor of supply units. The floating contacts are
mechanically connected to the integrated mains contactor.

2.

Supply units without integrated mains contactor (HMV01.1R-W0120): Re


ceives message signals on the status of the external mains contactor.

Pin assignment

Connec
tion

Signal
name

Function

Supply units with integrated mains contactor


4

A) N/O contact

closed with mains contactor


picked up

B) N/C contact

open with mains contactor picked


up

Supply units without integrated mains contactor

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

287/315

Functions and Electrical Connection Points


Pin assignment

Connection Diagram

Properties

Connec
tion

Signal
name

Function

A) connection for N/O contact

feedback from external mains


contactor

B) connection for N/C contact

feedback from external mains


contactor

Fig.8-44:

Function, pin assignment

K1
L, N

external mains contactor


supply voltage of control circuit for mains connection

Supply units without integrated mains contactor

Fig.8-45:
Data

X34 connection diagram - block diagram


Unit
Min.

number of poles

Typ.
4

type

spring terminal

design

pins at device

Max.

288/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


Data

Unit

Min.

connection cable solid wire

mm2

0,5

1,5

connection cable stranded wire

mm2

0,5

1,5

AWG

20

16

Max.

current load capacity

peak current when switching on

voltage load capacity

DC30

minimum load of contacts

mA

contact resistance at minimum


load

10

mOhm

1000

number of mechanical switching


cycles

106

number of switching actions at


max. time constant of load

100.000

time constant of load

ms

50

pick up delay

ms

10

drop out delay

ms

10

Fig.8-46:

8.15

Typ.

Properties

X34, Contact for Controlling the External Mains Contactor


View

Function, Pin Assignment

Fig.8-47:

View

The contact at X34 is used to control the external mains contactor of supply
units without integrated mains contactor (e.g. HMV01.1R-W0120). The contact
is included in the control circuit for mains connection.
Pin assignment

Fig.8-48:

Connec
tion

Signal
name

Function, pin assignment

Function
N/O contact

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

289/315

Functions and Electrical Connection Points


Connection Diagram

K1
L, N
Properties

Fig.8-49:
Data

external mains contactor


supply voltage of control circuit for mains connection

X34 connection diagram - block diagram


Unit
Min.

number of poles

Typ.

Max.

type

spring terminal

design

pins at device

connection cable solid wire

mm2

0,5

1,5

connection cable stranded wire

mm2

0,5

1,5

AWG

20

16

current load capacity

DC1
AC2

peak current when switching on

voltage load capacity

DC30
AC250

minimum load of contacts


contact resistance at minimum
load

mA
mOhm

10
1000

290/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


Data

Unit

Min.

number of mechanical switching


cycles

8.16

Max.

106

number of switching actions at


max. time constant of load

Notes on Installation

Typ.

100.000

time constant of load

ms

50

pick up delay

ms

10

drop out delay

ms

10

Fig.8-50:

Properties

Only use mains contactors with overvoltage limiter at the contactor coil (e.g.
mains contactor 3RT1456-6AP36 with overvoltage limiter 3RT1956-1CD00 by
Siemens).

Terminal Block, 24 - 0V (24V Supply)


Function, Pin Assignment

Connection of external 24V supply:

24V supply of HMS, HMD, HCS power sections (not at HCS02)

for the power section of the drive controller

for brake control via X6

for the control section of the drive controller with the optional modules,
except for such optional modules (e.g. safety technology S1) which require
their own power supply
24V supply of HMV supply units

for the integrated electronics

for the 24V interface of the mains connection for ON/OFF control
View

Identifica Function
tion
+24V

power supply
connection to neighboring devices with contact bars from the
HAS01.1 accessory

0V

reference potential for power supply


connection to neighboring devices with contact bars from the
HAS01.1 accessory

Screw connection

Unit

Min.

Max.

Nm

5,5

6,5

M6 thread at device (terminal block)


tightening torque
power consumption

see PN3 (see index entry with reference to the corresponding


page)

voltage load capacity

see UN3 (see index entry with reference to the corresponding


page)

polarity reversal protection

within the allowed voltage range by internal protective diode

Fig.8-51:

Function, pin assignment, properties

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

291/315

Functions and Electrical Connection Points


Connection Diagram

A
B
Notes on Installation

Fig.8-52:

cable (to source of control voltage supply)


contact bars

Connection points and connections of control voltage

Requirements on the connection to the 24V supply:

maximum allowed inductance of 100 H (2 twisted single strands, 75 m


long)

parallel line routing where possible


The input 0V is connected in conductive form with the housing po
tential. It is therefore impossible to use an insulation monitor at
+24V and 0V against housing.

8.17

DC Bus Connection (L+, L-)


Lethal electric shock caused by live parts with more than 50 V!

Wait at least 30 minutes after switching off power to allow discharging. To


shorten the waiting time until voltage has fallen below 50 V, you can use
a discharging device (see chapter Appendix in this documentation).

Check whether voltage has fallen below 50 V before touching live parts!

WARNING
Function, Pin Assignment

The DC bus connection connects

several drive controllers to one another

a drive controller to additional components


HCS02.1E-W0012 drive controllers do not have a DC bus connec
tion.

292/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


View

Identifica Function
tion
L+
L-

Screw connection

connection points for homopolar connection of involved DC


bus connections via contact bars

Unit

Min.

Max.

Nm

5,5

6,5

M6 thread at device (terminal block)


tightening torque
short circuit protection

via fusing elements connected in the incoming circuit to the


mains connection

overload protection

via fusing elements connected in the incoming circuit to the


mains connection

Notes on Installation

Fig.8-53:

Function, pin assignment, properties

Fig.8-54:

Contact bars

If in special cases it is not possible to use the contact bars provided to establish
the connection, the connection must be established using the shortest possible
(2 2 m, as a maximum) and twisted wires.

Damage caused by voltage arcing!


CAUTION

Insulate ring terminals and connecting lines with a heat-shrinkable sleeve. Af


terwards only strip the insulation of the contact surface of the ring terminal.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

293/315

Functions and Electrical Connection Points


The cross section of the lines must be at least 10 mm2, but mustn't be smaller
than the cross section of the supply feeder at mains connection X3.
The dielectric strength of the single strand must be at least 750 V (e.g. strand
type H07).

8.18

XS1, Shield Connection Control Lines


Risk of damage caused by high temperature of the outgoing air!
Observe outlet temperatures at the top of the drive controllers.

CAUTION
Always connect the shields with the largest possible metal-to-metal
contact surface.

Fig.8-55:
Function

8.19

Shield connection XS1 (control lines)

Connection point for the shields of lines connected to the control section and
of which the connectors do not have their own shield connection.

XS2, Shield Connection Motor Cable


Risk of damage to the drive controller caused by too long screws!

CAUTION

Exclusively use screws of a maximum length of 12 mm for the thread of shield


connection XS2.
The connection consists of an M6 thread and is used for mounting the shielding
plate for shield connection of the motor power cable (accessory HAS02.1).

294/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points

8.20

Ground Connection
The ground connection of the housing is used to provide functional safety of
the drive controllers and protection against contact in conjunction with the
equipment grounding conductor.
Ground the housings of the drive controllers:
1.

Connect the bare metal back panel of the drive controller in conductive
form to the mounting surface in the control cabinet. To do this use the
supplied mounting screws.

2.

Connect the mounting surface of the control cabinet in conductive form to


the equipment grounding system.

Damage to the devices by voltage arcing!

For applications with static charging (e.g. printing, packaging), a ground


ing principle similar to the one for the TNC mains must be complied with.
For mains unequal TNC, it is therefore necessary to install an isolating
transformer (UK 2,5%).

The grounding impedance (measured at connection point of machine)


must always be smaller than 8 ohm.

CAUTION

8.21

Connection Point of Equipment Grounding Conductor, HMV


Lethal electric shock caused by live parts with more than 50 V!
Via the joint bar on the front connect the drive controller to the supply unit.

DANGER

Via the joint bar on the front connect the drive controller to the neighboring drive
controller.
Connect the equipment grounding conductor connection of the supply unit to
the equipment grounding conductor system of the control cabinet.
Check the continuity of the equipment grounding conductors from the mains
connection to the connected motors.
Cables for connecting the equipment grounding conductor must
have at least the cross section (wire size) of the mains supply feed
er. If the cross sections (wire sizes) of the mains supply feeder are
smaller than 10 mm2 (AWG 8), the equipment grounding conductor
must be at least 10 mm2 (AWG 8).

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

295/315

Functions and Electrical Connection Points

1
2

joint bar
equipment grounding conductor connection at supply unit

1
2

joint bar
equipment grounding conductor connection at supply unit

Fig.8-56:

Fig.8-57:
Design

Equipment grounding conductor connection at the supply unit or neigh


boring device

Equipment grounding conductor connection at the HMV01.1-W0120


supply unit or neighboring device

The equipment grounding conductor is connected with screws:


HMV01.1E-W0030, -W0075

HMV01.1E-W0120

HMV01.1R-W0018, -W0045, -W0065

HMV01.1R-W0120

HMV02.1R-W0015
M6 25

Fig.8-58:

Design

M10

296/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Functions and Electrical Connection Points


Tightening Torque

HMV01.1E-W0030, -W0075

HMV01.1E-W0120

HMV01.1R-W0018, -W0045, -W0065

HMV01.1R-W0120

HMV02.1R-W0015
6 Nm

Fig.8-59:

8.22

18 Nm

Tightening torque

Equipment Grounding Conductor Connection HMS, HMD


Lethal electric shock caused by live parts with more than 50 V!

DANGER

Connect the drive controller to the equipment grounding system of the control
cabinet.
Supplying device with connection for joint bar:

Via the joint bar on the front, connect the drive controller to the supplying
device.

Supplying device without connection for joint bar:

Via a separate connection line, connect the drive controller to the equip
ment grounding system of the control cabinet.

Via the joint bar on the front, connect the drive controller to the neighboring
drive controller.
Connect the equipment grounding conductor connection of the supplying de
vice to the equipment grounding system of the control cabinet.
Check the continuity of the equipment grounding conductors from the mains
connection to the connected motors.
The wire for connecting the equipment grounding conductor must
have at least the cross section (wire size) of the mains supply feed
er. If the cross sections (wire sizes) of the mains supply feeder are
smaller than 10 mm2 (AWG 8), the equipment grounding conductor
must be at least 10 mm2 (AWG 8).

1
2

Fig.8-60:

joint bar
connection to equipment grounding system

Equipment grounding conductor connection for supply via HMV01,


HMV02, HCS03

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

297/315

Functions and Electrical Connection Points

1
2

Fig.8-61:
Design, Tightening Torque

joint bar
connection to equipment grounding system

Equipment grounding conductor connection for supply via HCS02

The joint bars are connected with screws:


Device

Design

Tightening torque

M6 25

6 Nm

HMS01.1N
HMS02.1N
HMD01.1N

Fig.8-62:

Data of connection point

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

299/315

Touch Guard at Devices

Touch Guard at Devices

9.1

Cutouts
Lethal electric shock caused by live parts with more than 50 V!

WARNING

The appropriate touch guard must be mounted for each device following
connection work.

Never mount a damaged touch guard.

Immediately replace a damaged touch guard by an undamaged touch


guard.

Keep the cutouts at the touch guard as small as possible. Only remove
the cutouts if necessary.

Type 1

Type 2

Fig.9-1:

Cutouts at the touch guard

If the DC bus and the control voltage are connected by means of contact
bars, only cutout A may be removed from the touch guard.

If the DC bus and the control voltage are connected by means of cables
(e.g. in the case of multiple-line arrangement), the cutouts A, B and C may
be removed from the touch guard.

At the first and last device in a line of interconnected devices, you must
not remove any cutout at the outer side of the touch guard.

300/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Touch Guard at Devices

9.2

Mounting

Fig.9-2:

Touch guard at device

The touch guard is fixed to the device with screws.


Tightening Torque

max. 2,8 Nm

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

301/315

Operation and Diagnosis

10

Operation and Diagnosis

10.1

Operation and Diagnosis at IndraDrive Supply Units

10.1.1

Control Panel

Brief Description
Rexroth IndraDrive supply units have a standard control panel with an 8digit
display and four keys.

Fig.10-1:

Standard control panel with display and keys

Functional Description
Displays
The display automatically shows:

phases during device initialization

operating states

activated commands

diagnostic command messages

warnings

diagnostic error messages

Display During Device Initialization

P2
P3

Fig.10-2:

phase 2
phase 3

Display during device initialization

302/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Operation and Diagnosis


Display of Operating States

Diagnostic Command Messages

Warnings and Diagnostic Error


Messages

bb
Bb
charg
Lb

ready for operation


ready for operation, mains voltage applied
DC bus charging
ready for power output

A)
B)

displays currently active command


displays number of diagnostic command message

A)
B)

displays error class and warning class


displays error number and warning number

Fig.10-3:

Fig.10-4:

Fig.10-5:

Display of operating states

Diagnostic command messages

Warnings and diagnostic error messages

Priorities of Display
The displays have different priorities because it is impossible to have various
displays at the same time.
The current drive status is displayed with highest priority.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

303/315

Operation and Diagnosis

E)
D)
C)
B)
A)

Fig.10-6:

error messages (highest priority)


warnings
diagnostic command messages
commands
operating status (lowest priority)

Priority of displays with examples

Complete Diagnostic Message Text


Call complete diagnostic message text for diagnostic message currently dis
played:

initial state: standard display (e.g. "VM F8057")

press key "v" or "^"

The diagnostic message text is displayed in the form of a marquee text. After
the marquee text was completely displayed, the standard display appears
again.

B)
A)

Fig.10-7:

current diagnostic message (marquee text)


standard display

Calling complete diagnostic message text

304/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Operation and Diagnosis

Extended Displays
Call extended displays (see also figure below):

initial state: standard display (e.g. "VM Lb")

simultaneously press "Enter" and "Esc" keys for at least 8 seconds

press "Enter" key

press "v" or "^" key until desired display appears

press "Enter" key

Fig.10-8:

Calling extended displays

There are the following extended displays:

1.1 ErrBuff: error memory; with the "v" or "^" key you can browse the
memory

1.2 DiagBuf: diagnostic message memory; with the "v" or "^" key you can
browse the memory

1.3 Lfcnt: operating hours counter control section

1.4 Lfcnt: operating hours counter power section (only for HMV01.1R)

1.5 FW-***: type designation of the firmware active in the device

Setting the Language


Set language in which diagnostic message texts are displayed (see also figure
below):

initial state: standard display (e.g. "VM Lb")

simultaneously press "Enter" and "Esc" keys for at least 8 seconds

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

305/315

Operation and Diagnosis

press "^" key

press "Enter" key

press "Enter" key

with "v" or "^" key select the desired language

Fig.10-9:

10.1.2

Setting the language

Diagnostic Messages Displayed at IndraDrive M Supply Units

HMV - Diagnostic Messages for Operating States and During the Initialization Phase
For detailed descriptions of the diagnostic messages mentioned in
this chapter, see Troubleshooting Guide of the firmware documen
tation.
Display
VM P0
VM P1
VM P2
VM P3
VM Bb
VM bb
VM Lb
VM I Lb
VM Lb
VM charg
VM lb
VM ZKS
VM AF

Fig.10-10:

Diagnostic message number Diagnostic message


A0000
Communication phase 0
A0001
Communication phase 1
A0002
Communication phase 2
A0003
Communication phase 3
Control and power sections
A0012
ready for operation
A0013
Ready for power on
Supply module in voltage
A0500
control
Supply module in current
A0501
control
A0502
Supply module in operation
A0503
DC bus charging active
A0510
Test run for voltage control
DC bus quick discharge ac
A0520
tive
A0800
Unknown operating mode

Initialization and operating states HMV

HMV - Diagnostic Warning Messages


For detailed descriptions of the diagnostic messages mentioned in
this chapter, see Troubleshooting Guide of the firmware documen
tation.

306/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Operation and Diagnosis

Display
VM E2026
VM E2050
VM E2061
VM E2810
VM E2816
VM E2819
VM E2820
VM E8025
VM E8057

Fig.10-11:

Diagnostic message number Diagnostic message


Undervoltage in power sec
E2026
tion
Device overtemp. Prewarn
E2050
ing
E2061
Device overload prewarning
Drive system not ready for
E2810
operation
Undervoltage in power sec
E2816
tion
E2819
Mains failure
Braking resistor overload
E2820
prewarning
Overvoltage in power sec
E8025
tion
Device overload, current lim
E8057
it active

Diagnostic warning messages HMV

HMV - Diagnostic Error Messages


For detailed descriptions of the diagnostic messages mentioned in
this chapter, see Troubleshooting Guide of the firmware documen
tation.
Display
VM PL
VM F2018
VM F2022
VM F2026
VM F2077
VM F2087
VM F2110
VM F2802
VM F2814
VM F2815
VM F2816
VM F2817
VM F2818
VM F2819
VM F2820
VM F2821
VM F2833
VM F2834

Diagnostic message number Diagnostic message


PL Load parameter default
F2009
values
Device overtemperature
F2018
shutdown
Device temperature monitor
F2022
defective
Undervoltage in power sec
F2026
tion
Current measurement trim
F2077
wrong
Module group communica
F2087
tion error
Error in non-cyclical data
F2110
communic. of power section
F2802
PLL is not synchronized
F2814
Undervoltage in mains
F2815
Overvoltage in mains
Softstart fault power supply
F2816
unit
Overvoltage in power sec
F2817
tion
F2818
Phase failure
F2819
Mains failure
F2820
Braking resistor overload
Error in control of braking re
F2821
sistor
F2833
Ground fault in motor line
F2834
Contactor control error

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

307/315

Operation and Diagnosis


Display
VM F2835

Diagnostic message number Diagnostic message


F2835
Mains contactor wiring error
DC bus balancing monitor
F2836
error
F2837
Contactor monitoring error
F2840
Error supply shutdown
Overcurrent in mains-side
F2860
power section
F2890
Invalid device code
F2891
Incorrect interrupt timing
Hardware variant not sup
F2892
ported
F8057
Device overload shutdown
F8069
+/-15Volt DC error
F8070
+24Volt DC error
Connection error mains
F8813
choke
F9001
Error internal function call
F9003
Watchdog
F9004
Hardware trap

VM F2836
VM F2837
VM F2840
VM F2860
VM F2890
VM F2891
VM F2892
VM F8057
VM F8069
VM F8070
VM F8813
VM F9001
VM F9003
VM F9004

Fig.10-12:

Diagnostic error messages HMV

HMV - Diagnostic Command Messages


For detailed descriptions of the diagnostic messages mentioned in
this chapter, see Troubleshooting Guide of the firmware documen
tation.
Diagnostic command messages HMV
Display
VM C01
VM C0101
VM C0102
VM C02
VM C0201
VM C0202
VM C0203
VM C0212
VM C04
VM C0401
VM C05
VM C08

Diagnostic message number Diagnostic message


Communication phase 3
C0100
transition check
Invalid parameters (->
C0101
S-0-0021)
Limit error in parameter (->
C0102
S-0-0021)
Exit parameterization level
C0200
procedure command
Invalid parameters (C0201
>S-0-0423)
Parameter limit error (C0202
>S-0-0423)
Parameter calculation error
C0203
(->S-0-0423)
Invalid control section data (C0212
>S-0-0423)
Activate parameterization
C0400
level 1 procedure command
C0401
Switching not allowed
Reset class 1 diagnostics,
C0500
error reset
Load basic parameters com
C0800
mand

308/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Operation and Diagnosis


Display
VM C0851
VM C0852

Fig.10-13:

Diagnostic message number Diagnostic message


Parameter default value in
C0851
correct (-> S-0-0021)
C0852
Locked with password

Diagnostic command messages HMV

10.2

Operation and Diagnosis at IndraDrive Controllers

10.2.1

Control Panel
For the detailed description of the standard control panel, see sec
tion Control Panels in the Functional Description of the firmware
documentation.

10.2.2

Diagnostic Messages Displayed at Drive Controllers


For detailed descriptions of all diagnostic messages displayed at
drive controllers, see Troubleshooting Guide of the firmware docu
mentation.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

309/315

Disposal and Environmental Protection

11

Disposal and Environmental Protection

11.1

Disposal

11.1.1

Products
Our products can be returned to us free of charge for disposal. It is a precon
dition, however, that the products are free of oil, grease or other dirt.
Furthermore, the products returned for disposal mustn't contain any undue for
eign matter or foreign component.
Please send the products free domicile to the following address:
Bosch Rexroth AG
Electric Drives and Controls
Brgermeister-Dr.-Nebel-Strae 2
D-97816 Lohr am Main

11.1.2

Packaging Materials
The packaging materials consist of cardboard, wood and polystyrene. These
materials can be easily recycled in any municipal recycling system. For eco
logical reasons, please refrain from returning the empty packages to us.

11.2

Environmental Protection

11.2.1

No Release of Hazardous Substances


Our products do not contain any hazardous substances which may be released
in the case of appropriate use. Accordingly, our products will normally not have
any negative effect on the environment.

11.2.2

Materials Contained in the Products

Electronic Devices
Electronic devices mainly contain:

steel

aluminium

copper

synthetic materials

electronic components and modules

Motors
Motors mainly contain:

steel

aluminium

copper

brass

magnetic materials

electronic components and modules

310/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Disposal and Environmental Protection

11.2.3

Recycling
Due to their high content of metal, most of the product components can be
recycled. In order to recycle the metal in the best possible way, the products
must be disassembled into individual modules.
Metals contained in electric and electronic modules can also be recycled by
means of special separation processes. The synthetic materials remaining after
these processes can be thermally recycled.
If the products contain batteries or accumulators, these have to be removed
before recycling and disposed of.

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

311/315

Service & Support

12

Service & Support

12.1

Helpdesk
Our service helpdesk at our headquarters in Lohr, Germany, will assist you with
all kinds of enquiries.
Contact us:

By phone through the Service Call Entry Center,


Mo - Fr 7:00 am - 6:00 pm CET
+49 (0) 9352 40 50 60

By Fax
+49 (0) 9352 40 49 41

12.2

By email: service.svc@boschrexroth.de

Service Hotline
Out of helpdesk hours please contact our German service department directly:
+49 (0) 171 333 88 26
or
+49 (0) 172 660 04 06
Hotline numbers for other countries can be found in the addresses of each
region (see below).

12.3

Internet
Additional notes regarding service, maintenance and training, as well as the
current addresses of our sales and service offices can be found on
http://www.boschrexroth.com
Outwith Germany please contact our sales/service office in your area first.

12.4

Helpful Information
For quick and efficient help please have the following information ready:

detailed description of the fault and the circumstances

information on the type plate of the affected products, especially type co


des and serial numbers

your phone / fax numbers and e-mail address so we can contact you in
case of questions

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

313/315

Index

Index
Symbols

24V supply 277, 290

Ambient conditions 20
Appropriate use 5
Applications 5

Braking resistor
External 275
Switch-on threshold 284

Cables
IKB0041 260
Capacity utilization 22
CCC, China Compulsory Certification 18
CE label 17
Certifications 17
Commissioning interface 259
Compatibility with foreign matters 22
Connection
Braking resistor 275
Control voltage 277
DC bus 291
Equipment grounding conductor HMS, HMD
296
Ground 294
Shield (control lines) 293
Shield (motor cable) 293
Connection diagrams
RS 232 260
Serial interface 260
Connection point
Equipment grounding conductor HMV 294
Connections
Electrical, at converters 255
Electrical, at inverters 255
Electrical, at supply units 255
Control voltage 277, 290
Converters
Types 25
C-UL-US listing 17
Current profile
UEL_I_e 52, 91, 130, 154, 180

DC bus
Connection 291
DC bus short circuit 284
Declaration of conformity 17
Documentations
Overview 1

Equipment grounding conductor


Connection HMS, HMD 296
Equipment grounding conductor HMV
Connection point 294

Foreign matters
Compatibility with 22

Ground
Connection 294
Ground connection 294

HMV01
Mains synchronization 280
HMV02
Mains synchronization 281
HMV02, regenerative 230

Inappropriate use, 6
Consequences, exclusion of liability 5
Installation conditions 20
Inverters
Types 99

Mains connection, 260


Single-phase 46
Mains contactor
Acknowledge messages 286
External 288
Mains contactor control 284
Mains synchronization
HMV01 280
HMV02 281
Mains voltage synchronization 280
Messages Bb1, UD, WARN
X31 282
Module bus 258
Motor connection 266
Motor temperature monitoring and motor holding
brake 272
Motor holding brake 272
Motor temperature monitoring 272
Mounting positions 21

Operating conditions 20

314/315

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Index

Performance profile
Infeeding supply units 202
Regenerative supply units 223, 244
UEL_P_e 54, 93, 132, 181
Positions of normal use 21
Power sections HCS02 25
Power sections HCS03 62
Power sections HMD01 162
Power sections HMS01 99
Power sections HMS02 140

RS232 259

Safety instructions for electric drives 7


Scope of supply
Power section HCS02 32
Power section HCS03 66
Power section HMD 166
Power section HMS01 104
Power section HMS02 143
Supply unit HMV02-R 233
Supply units 190, 211
Serial interface (RS232) 259
Service interface 259
Shield
Connection (control lines) 293
Connection (motor cable) 293
Single-phase mains connection 46
Specifications
Of the components 17
Standard motors
Voltage load 49, 88, 124, 154, 177
State-of-the-art 5
Storage
Of the devices 19
Supply HAB01 278
Supply units
Overview - types 187
Supply units HMV01
Infeeding 187
Regenerative 209
Supply units HMV02
Regenerative 230

Technical data
Serial interface 259
Touch guard 299
Transport
Of the devices 19
Type code 29

Use
Appropriate use 5
Inappropriate use 6

VM AF 305
VM bb 305
VM Bb 305
VM C01 307
VM C0101 307
VM C0102 307
VM C02 307
VM C0201 307
VM C0202 307
VM C0203 307
VM C0212 307
VM C04 307
VM C0401 307
VM C05 307
VM C08 307
VM C0851 308
VM C0852 308
VM charg 305
VM E2026 306
VM E2050 306
VM E2061 306
VM E2810 306
VM E2818 306
VM E2819 306
VM E2820 306
VM E8025 306
VM E8057 306
VM F2018 306
VM F2022 306
VM F2026 306
VM F2077 306
VM F2087 306
VM F2110 306
VM F2802 306
VM F2814 306
VM F2815 306
VM F2816 306
VM F2817 306
VM F2818 306
VM F2819 306
VM F2820 306
VM F2821 306
VM F2833 306
VM F2834 306
VM F2835 307
VM F2836 307
VM F2837 307
VM F2840 307
VM F2860 307
VM F2890 307
VM F2891 307

Project Planning Manual | Rexroth IndraDrive

Electric Drives | Bosch Rexroth AG


and Controls

315/315

Index
VM F2892 307
VM F8057 307
VM F8069 307
VM F8070 307
VM F8813 307
VM F9001 307
VM F9003 307
VM F9004 307
VM I Lb 305
VM lb 305
VM Lb 305
VM P0 305
VM P1 305
VM P2 305
VM P3 305
VM PL 306
VM ZKS 305

X1

Module bus 258

X13 277
X13 - HMV 278
X14 280
X2
Serial interface (RS232) 259
X3 260
X31
Messages Bb1, UD, WARN 282
X32
Mains contactor control and DC bus short circuit
284
X33
Acknowledge messages of mains contactor 286
X34
Contact for controlling the external mains con
tactor 288
X5 266
X9 275
XS1 293
XS2 293

Bosch Rexroth AG | Electric Drives


and Controls

Rexroth IndraDrive | Project Planning Manual

Project Planning Manual | Rexroth IndraDrive

Notes

Electric Drives | Bosch Rexroth AG


and Controls

Bosch Rexroth AG
Electric Drives and Controls
P.O. Box 13 57
97803 Lohr, Germany
Bgm.-Dr.-Nebel-Str. 2
97816 Lohr, Germany
Phone +49 (0)93 52-40-50 60
Fax
+49 (0)93 52-40-49 41
service.svc@boschrexroth.de
www.boschrexroth.com

R911318790

Printed in Germany
DOK-INDRV*-HMV-S-D+HCS-PR01-EN-P

You might also like