Installation Instructions

Innovate. Connect.

Compression connectors for AVA7-50, AL7-50, LDF7, LCF 158, LCF 158 JA, & VXL7

1-5/8” Frame Set

Hack Saw
CC-DF-A7
CC-DF-L7
CC-DF-JA7
HCG Tool

wear
Always sses
g la
safety rating
o p e SP-158 Prep/Strip Tool
when KIT-HCG-1-5/8 PPC Tool Kit
tool

Safety Glasses Port Seal

With a few simple steps, PPC compression connectors can be easily and consistently installed on 1-5/8” cable

Step #1

A. Straighten cable and position B. Insert correct center C. Attach coring tool & stripping D. Set drill speed to LOW
hacksaw in valley of corrugation conductor pin into coring tool tool to drill
and cut off the cable square. and firmly tighten.
NOTE: – if using VXL cable use
“VXL” pin
Step #2

A. Remove the jacket until B. Release blade lever and C. Blade lever will rest flat when D. Remove coring tool.
outer conductor hits fixed stop. operate drill clockwise and cut is complete
Be sure the cutting blade is counter clockwise to cut
positioned over the valley of the through inner and outer
corrugation. Use the ball detents conductor
as guide.

REV 8.0

6176 East Molloy Road • East Syracuse, NY 13057-0278 • Tel: 315-431-7200 • Fax: 315-431-7201 • E-mail:ppc@ppc-online.com • www.ppc-online.com
Installation Instructions
Innovate. Connect.

Compression connectors for AVA7-50, AL7-50, LDF7, LCF 158, LCF 158 JA, & VXL7

Step #3

A. Remove cable piece from B. Properly stripped and cut C. Set drill speed to HIGH D. Core cable to remove
the side of the stripping tool. cable is ready for dielectric dielectric until outer conductor
Remove cable from tool. removal. reaches stop on coring tool.

Step #4

A. Cable is properly cored B. Align outer conductor with C. Push connector onto cable
top edge of knurl on back piece until it reaches the mark on the
and mark cable in line with end cable.
of connector.

Step #5

A. Pull or push back the insert to B. Make sure connector is fully C. When fully compressed, D. Add port seal to connector
allow connector/cable to lay flat seated in frameset (lying flat). connector back will move away to ensure a moisture proof
in frame. Press tool trigger to compress from alignment mark. connection. The port seal should
the connector. Do not push on sit in the flat area behind the
tool/cable during compression. threads.
THIS STEP IS REQUIRED TO
PROTECT PRODUCT WARRANTY
REV 8.0

6176 East Molloy Road • East Syracuse, NY 13057-0278 • Tel: 315-431-7200 • Fax: 315-431-7201 • E-mail:ppc@ppc-online.com • www.ppc-online.com