You are on page 1of 28

35-1150 kV

315-3500 A

Publication 11.2011

"IZOLYATOR" PLANT performs design, manufacturing, warranty and postwarranty service of highvoltage
bushings for various applications.
The enterprise is the main supplier of highvoltage bushings for power industry in Russia and CIS countries.
Hundreds of thousands of bushings were manufactured and are in operation now.

Production program:
bushings from 35 to
1150 kV for power
transformers and shunt
reactors

high current bushings


from 20 to 35 kV for
transformerstobusbar
connection

bushings from 110 to


500 kV for cable connection of transformers

bushings from 35 to
220 kV for high voltage
circuitbreakers

wall bushings from 66


to 220 kV

220 kV bushings for cominsulated


plete
SF6
switchgears

The bushings of any climaticdependent design version are available.


All the bushings are interchangeable with manufactured previously in regard of overall dimensions and connecting
dimensions.

Quality management system according to requirements of international


s t a d a r d
EN ISO 9001:2008 is operating at the plant.

All the bushings are certified for compliance with


State Standard GOST
1069381 and other regulatory documents of Russia's
Gosstandard.
The bushings also comply
with Standard IEC 60137.

Kinds of insulation
Highvoltage bushings for power transformers and reactors are produced with
two kinds of internal condensertype insulation: RIP (Resin Impregnated Paper) and
OIP (Oil Impregnated Paper).

Design of the bushing with


RIPinsulation
I
Internal RIPinsulation is the main
structural part of the bushing; it is the insulating body formed by winding dielectric
paper divided by conductive grading layers
on the central tube (figure 1).
The grading layers serve for optimal
distribution of electric field in radial and
dielectric strength values of both internal

II

and external insulation, including the lower


part of the bushing placed inside the
transformer or reactor.
RIPinsulation is manufactured by winding crepe paper produced by Weidmann
Systems International AG (Switzerland) or
Karl

Fislage

GmbH

&

Co.

KG(Germany), then the paper is impreg-

SHED PROFILE

II

TEST TAP (side view)

Geometric dimensions may vary,


providing required creepage distance.

Figure 1

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

axial directions, providing the highest

Design of bushing with condenser  type RIP  insulation.

nated with epoxy compound under vacuum and


subsequently solidified under pressure.

Silicone rubber insulation is offered as an


alternative to porcelain insulation at bushings

RIPinsulation has practically no gas inclusions.

with internal RIP  insulation (figure 2).


The bushings equipped with such insulation

After thermal treatment and varnishing of

have the following advantages:

external surface, the insulating body forms a

absolutely dry, explosionproof design requir-

solid kernel, and a coupling is mounted on it

ing no maintenance;

under press fit.

high tracking resistance, hydrophobic behav-

The main advantages of RIPinsulation are

ior

of

external

insulation

preventing

high reliability and long service life performance

flashover without cleaning its surface, even

due to its low dielectric losses, low level of par-

in case of simultaneous exposure to moisture

tial discharges in the insulation, and high ther-

and contamination;

mal stability.

external insulation fins having constant or


varying spread, according to individual cus-

External insulation covers the upper part of

tomer's requirements;

the insulating body located outside the trans-

seismic load resistance;

former or reactor and is made of porcelain or

damageproof external insulation made of

silicone rubber.

organicsilicon composition, reducing risk of


damage during transportation and mounting;

Porcelain insulation is the porcelain housing


with the flange mounted on its top. The joints
between the porcelain housing, connecting
sleeve and the upper flange are sealed by gaskets made of oil resistant rubber.

minimum weight;
environmental safety;
stability of properties during the whole operation life.
Silicone rubber insulation is moulded of

Compression of gaskets is provided by the


spring tightening device ensuring stable strain
in case of length change of the insulating body
and porcelain housing in the range from 60 to
+120.

elastic material created on the basis of


proprietary organicsilicon compositions of
RTV2 type by Wacker Chemie GmbH,
Germany.
Moulded and polymerization takes place

The space between the insulating body and


porcelain housing is stuffed with filler for protection from moistering.

directly at the insulating body, thus completely


excluding usage of filler including the transformer oil. Besides, no spring tightening device

The design of the bushing ensures its

is needed.

reliable leaktightness.
Leaktightness of the transformer is ensured
even in case of damaging the bushing's porcelain housing. The spring tightening device is
placed

under

the

protective

casing,

leaktightness between the central tube and the


upper flange is provided by two rubber Oring
gaskets.

Pressure compensator is intended for


compensating changes of oil volume caused by
temperature variations. It is used only in the
bushings with external porcelain insulation
where transformer oil is used as a filling material. The compensator is provided by the gas
cushion located in the upper part of the bush-

ing.
Oil level is checked visually through the
oillevel sight glass at the protective housing.

Test tap connected to the last grading


layer of the insulating body serves for checking the internal insulation. The test tap shall
be obligingly grounded when measurements
are not performed (figures 1,2).
The design of test tap equipped with
springloaded contact anticipates connection
of diagnostic tools during operation.

Transportation and storage of the bushing require protection against moisture and
mechanical damage of the lower part of the
varnished surface of the body, submerged in
transformer oil during operation. Polyethylene
tin cylinder is used for this purpose.
Shield installed at the bottom part of the
bushing and intended for the electric field
compensation

SHED PROFILE

Geometric dimensions may vary,


providing required creepage distance.

Figure 2

Design of bushing with silicone rubber insulation.

II

TEST TAP
(except III90110/2500)

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

cover with silica gel desiccant and bakelite or

II

Design of the bushing with


OIPinsulation
Internal OIP insulation is the main structural
part of the bushing. It is the insulating body formed
by winding dielectric paper divided by conductive
grading layers on the central or winding tube (figure 3).
The grading layers serve for optimal distribution
of electric field in radial and axial directions, providing the highest dielectric strength values of both
internal and external insulation, including the lower
part of the bushing placed inside the transformer or
reactor.
For bushings with pulledthrough type connection*, which have high current rating, winding is
made around a separate tube so that a channel is
formed between the central tube and the winding
tube, where oil circulates to cool and level the temperature of the insulation body during operation.
For bushings with other type of connection, the
inside space of the central tube serves as such a
channel.
I

In 750 kV bushings for reactors and 1150 kV


bushings for transformers (figure 4), internal insulation is divided into two parts  the inner and the
outer insulation, so that additional oil circulation
channel is formed to achieve better cooling.
Prior to assembly the frame is vacuum dried.
After assembly the bushing is vacuum treated and
impregnated with transformer oil. Thermovacuum
treatment parameters ensure high reliability and
* See section "Connection".

Figure 3

TEST TAP (side view)

Design of bushing with condensertype OIPinsulation and gas cushion.

longterm performance of insulation during operation of the bushing.


External porcelain insulation consists of the upper and bottom
housings. Together with the coupling and the protective casing,
they form a hermetically sealed oilfilled cavity where the insulation
body is placed.
The top and bottom butt ends of the cavity are covered by
flanges. The joints between the porcelain housings, coupling and
protective casing are sealed by gaskets made of oil resistant rubber. Stable compression of gaskets is provided by spring tightening
device, compensating the length change of the parts when temperature varies in the range from 60 to +120. Compression of gaskets sealing joints between the central tube and the flange is
ensured by bolts.
Pressure compensator is intended for compensation of
changes of oil volume caused by temperature variations and is
located in the upper part of the bushing or in the external pressure
tank mounted at the transformer tank lid.
Gas cushion or leakproof metal bellows may be used as compensator.
Oil level in the bushings with gas cushion is checked visually
through the oillevel sight glass at the protective housing.

Test tap connected to the last grading layer of the insulating


body serves for checking the internal insulation. The test tap shall
be obligingly grounded when measurements are not performed (fig.
3).
The shield for leveling electric field is mounted in the lower part
of the bushing, except the bushings for reactors and some types of
transformers which have the shield as integral part of the design.
The shield is not mounted at the upper part of the bushings
(except 1150 kV bushings): special tests confirmed absence of
corona discharge for voltage which is 10% higher than the highest
operating phase voltage.

Modification
Earthquakeresistant bushings marked with "C" letter were additionally tested for maintaining operability in case of earthquakes
having magnitude up to 9 according to MSK64 scale, and guarantee keeping of operating parameters in case of earthquakes.
Highaltitude bushings marked with "" letter are intended for
usage at altitude over 1000 m above sea level.

Figure 4
1150kV bushing minus upper and
bottom shield.

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

Leaktightness of the bushing with bellows compensator is


checked by pressure indicator  manometer.

Connection
Depending on the method of connection to the transformer coil or reactor
coil, the bushings are classified as
follows.
1. Pulledthrough type bushings,
which are connected by means of
pulling the copper cable of the tap (see
table 1) with soldered contact stud

BOTTOM PART
OF PULLED-THROUGH
TYPE BUSHING

through the central tube of the bushing


(figure 5).
The contact stud is supplied with the
bushing and is soldered to the tap at the
place of installation of the bushing.
2. The bottomconnected bushings,
featuring connection implemented by
clamping the tap cable with special bolts
(figures 6a, b) or nuts (figure 6c) at the
bottom contact tip of the bushing.

Figure 5

The bottomconnected bushings

Currentcarrying system of pulledthrough type


bushings.

with plugin connector, featuring connection implemented by inserting the


plug located at the bottom end of the

bushing into the socket at the end of the


tap (figure 6d).
In the first case, the tap cable from
the transformer winding serves as the
conductor, while in the second case 
the bushing's central tube.

Table 1
Rated current, A

400
500
630
800
1000
1250
1600
2000
2500

Cable crosssection, mm2

1
1
1
1

x
x
x
x

150
185
300
300

1
2
3
3
4
4
4

500
300
185
240
300
400
500

Figure 6

Kinds of bottomconnected bushings.

For connecting leadin from the busbar, the terminal is

screwed to the threading of the upper contact stud (figure 7).


The terminal is supplied together with the bushing and is
fixed to the contact stud at the place of installation.

Technical data

The main information for choosing the bushing is contained in its code designation (figure 8).
Technical specifications, overall, fitting and connecting
dimensions of the bushings are presented at figures 57 and
in table 2.

 High altitude

 Hermetic design version

 Extended lower part (standard length by default)

 Internal RIPinsulation

 Internal OIPinsulation

 External silicone rubber insulation (porcelain by default)

 Bushing for shunt reactors

 Bushing for transformers (autotransformers)

III60220/2000
Rated current, A
Rated voltage, kV
Limit angle of vertical orientation, angular degree
External insulation category depending on ambient
contamination, according to GOST 992089 and
Standard IEC 60137

Figure 7

Kinds of terminal plates.

Figure 8

Key to bushing designation


code.

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

80

Table 2. Part 1 of 7

Technical data of high voltage bushings.

RIP

72,5

42

1250 140

IV-60-52/630
.686351.167

RIP

52

30

630

IV-60-52/800
.686351.167-01

RIP

52

30

IV-90-52/2000
.686351.257

RIP

52

III-60-72,5/630
.686351.101

RIP

III-90-72,5/630
.686351.201

7e

Switching impulse
250 /2500 s

95

1 minute, 50 Hz

Connection type, figure No.

3500

Weight, kg

Rated current, A

25

Test cantilever load, N

Phase to earth voltage, kV

40,5

Creepage distance, mm

Rated voltage, kV

RIP

Bushing type
Drawing No.

Lightning impulse
1.2/50 s

Type of internal insulation

Test voltage, kV

95

190

1160 3150

325

1800 2000 110 5,7e

95

250

1900 1600

60

800

100

250

1900 1250

60

30

2000

70

170

1650 1250

50

72,5

42

630

140

325

1810 1000

62

RIP

72,5

44

630

140

325

1800 2000 29,5 5,7

III-60-72,5/2000
.686351.102

RIP

72,5

44

2000 140

325

1810 3150 143 5,7e

III-90-72,5/2000
.686351.202

RIP

72,5

44

2000 140

325

1800 3150

78

5,7e

III60126/800
.686352.103

RIP

126

73

800

230

550

3150 1250

89

5,7

III90126/800
.686352.203

RIP

126

73

800

230

550

3150 1250

42

5,7

III60126/800
.686352.303

RIP

126

73

800

230

550

3150 1250

86

5,7

III60126/800
.686352.10301

RIP

126

73

800

230

550

3150 1250

87

5,7

40.5 kV bushings
III-60-40,5/3500
.686351.154

36 kV bushings
IV-60-36/1250
.686351.168

52 kV bushings

72.5 kV bushings
5,7

126 kV bushings

TOP VIEW
Enlarged

Overall, fitting and connecting dimensions of high voltage bushings.

L1

L2

L3

arcing
distance
transformer tap
length
housing/shield
diameter
max.
passthrough

length of bottom
part
current transformer length
height of central
flange

Bushing type
Drawing No.

length of bushing

Dimensions, mm

L4

L5

1645 670

400 125 460

1480 470

300

IV-60-52/630
.686351.167

1360 550

IV-60-52/800
.686351.167-01

1400 315

IV-90-52/2000
.686351.257

1385 500

D3

Bottom
shield

Mounting flange*

D1

D2

d
nholes

Pulled  throungh type


connection

L6

D4

d1 d2
n1holes

d3

d4

183 106 270 225 20/6 25

183 106 290 250 15/8

300 125 620 1365 186 106 290 250 15/8

106 225 200 15/6

125 620 1130 186 106 350 300 20/8

970 148 106 350 300 20/8

50

80

30

36

50

80

30

30

36

50

80

30

30

36

50

80

30

40.5 kV bushings
III-60-40,5/3500
.686351.154

36 kV bushing
IV-60-36/1250
.686351.168

460

125 620 1130 186 106 290 250 15/8 25

250 115 560

72.5 kV bushings
III-60-72,5/630
.686351.101

1360 315

III-90-72,5/630
.686351.201

1235 315

III-60-72,5/2000
.686351.102

1980 785

300

620 1643 255 165 528 480 24/9

60

165

32/4 89

III-90-72,5/2000
.686351.202

1825 785

500

598 1470 220 165 528 480 24/9

60

165

32/4 89

III60126/800
.686352.103

2080 660

200 125 1000 1850 186 106 350 300 24/8 25

30

36

50

80

30

III90126/800
.686352.203

2030 660

200 125 1055 1770

30

37

50

80

30

III60126/800
.686352.303

2080 660

200

30

36

50

80

30

III60126/800
.686352.10301

2190 770

300 125 1000 1960 186 106 290 250 15/8 25

30

36

50

80

30

607

126 kV bushings

106 350 300 24/8 25

1000 1850 186 106 350 300 24/8

* Connecting dimensions of the mounting flange may be modified according to Customer's requirements.

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

52 kV bushings

Table 2. Part 2 of 7

Technical data of high voltage bushings.

Weight, kg

Connection type, figure No.

800

230

550

3150 1250

40

5,7

III60126/800
.686352.30301

RIP

126

73

800

230

550

3150 1250

85

5,7

III60126/800
.686352.10302

RIP

126

73

800

230

550

3150 1250

92

5,7

III90126/800
.686352.20302

RIP

126

73

800

230

550

3150 1250

44

5,7

III60126/800
.686352.30302

RIP

126

73

800

230

550

3150 1250

88

5,7

III60126/800
.686352.10303

RIP

126

73

800

230

550

3150 1250 102 5,7

III90126/800
.686352.20303

RIP

126

73

800

230

550

3150 1250

55

5,7

III60126/800
.686352.30303

RIP

126

73

800

230

550

3150 1250

98

5,7

IV60126/800
.686352.10304

RIP

126

73

800

230

550

3900 1250 112 5,7

III90126/800
.686352.20304

RIP

126

73

800

230

550

3150 1250

III60126/800
.686352.30304

RIP

126

73

800

230

550

3900 1250 100 5,7

III-90-126/800
.686352.203-05

RIP

126

73

800

230

550

3150 1250

41

5,7

III-90-126/800
.686352.203-06

RIP

126

73

800

230

550

3150 1250

39

5,7

IV-90-126/800
.686352.203-07

RIP

126

IV-60-126/800
.686352.303-05

RIP

126

73

800

230

550

3150 1250

98

5,7

III-60-126/2000
.686352.104

RIP

126

73

2000 230

550

3150 4000 155 5,7e

Test cantilever load, N

Switching impulse
250 /2500 s

73

Creepage distance, mm

1 minute, 50 Hz

126

Lightning impulse
1.2/50 s

Rated current, A

RIP

Rated voltage, kV

III90126/800
.686352.20301

Bushing type
Drawing No.

Type of internal insulation

Phase to earth voltage, kV

Test voltage, kV

126 kV bushings (continuation)

TOP VIEW
Enlarged

10

41

5,7

800

Overall, fitting and connecting dimensions of high voltage bushings.

L1

L2

L3

arcing
distance
transformer tap
length
housing/shield
diameter
max.
passthrough

length of bottom
part
current transformer length
height of central
flange

Bushing type
Drawing No.

length of bushing

Dimensions, mm

L4

L5

D3

Bottom
shield

Mounting flange*

D1

D2

d
nholes

Pulled  throungh type


connection

L6

D4

d1 d2
n1holes

d3

d4

30

37

50

80

30

30

36

50

80

30

III90126/800
.686352.20301

2140 770

300 125 1055 1880

III60126/800
.686352.30301

2190 770

300

III60126/800
.686352.10302

2390 970

500 125 1000 2160 186 106 290 250 15/8 25

30

36

50

80

30

III90126/800
.686352.20302

2340 970

500 125 1055 2080

30

37

50

80

30

III60126/800
.686352.30302

2390 970

500

30

36

50

80

30

III60126/800
.686352.10303

2390 970

200 125 1000 2160 186 106 535 480 24/9 25

30

36

50

80

30

III90126/800
.686352.20303

2340 970

200 125 1055 2080

30

37

50

80

30

III60126/800
.686352.30303

2390 970

200

30

36

50

80

30

IV60126/800
.686352.10304

2390 770

300 125 1200 2160 186 106 290 250 15/8 25

30

36

50

80

30

III90126/800
.686352.20304

1980 610

300 125 1055 1715

30

37

50

80

30

III60126/800
.686352.30304

2390 770

300

1200 2160 186 106 290 250 15/8

30

36

50

80

30

III-90-126/800
.686352.203-05

1980 610

300

1055 1715 148 106 290 250 15/8 25

30

37

50

80

30

III-90-126/800
.686352.203-06

1845 475

170

1055 1630 148 106 290 250 15/8 25

30

37

50

80

30

IV-60-126/800
.686352.303-05

2280 660

200

1200 2050 186 106 350 300 24/8

30

36

50

80

30

III-60-126/2000
.686352.104

2275 720

400

960 1920 260 165 420 380 22/12

60

165

32/4 89

106 290 250 15/8 25

1000 1960 186 106 290 250 15/8

106 290 250 15/8 25

1000 2160 186 106 290 250 15/8

106 535 480 24/9 25

1000 2160 186 106 535 480 24/9

106 290 250 15/8 25

IV-90-126/800
.686352.203-07

* Connecting dimensions of the mounting flange may be modified according to Customer's requirements.

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

126 kV bushings

11

Table 2. Part 3 of 7

Technical data of high voltage bushings.

Connection type, figure No.


5,7e

550

3150 4000

III-60-126/2000
.686352.104-01

RIP

126

73

2000 230

550

3150 4000 165 5,7e

III-90-126/2000
.686352.204-01

RIP

126

73

2000 230

550

3150 4000

IV-60-126/2000
.686352.104-02

RIP

126

73

2000 230

550

3900 4000 200 5,7e

IV-90-126/2000
.686352.204-02

RIP

126

73

2000 230

550

3900 4000

IV-60-126/2000
.686352.104-03

RIP

126

73

2000 230

550

3900 4000 205 5,7e

IV-90-126/2000
.686352.204-03

RIP

126

73

2000 230

550

3900 4000 100 5,7e

IV-60-126/2000
.686352.104-04

RIP

126

73

2000 230

550

3900 4000 202 5,7e

IV-90-126/2000
.686352.204-04

RIP

126

73

2000 230

550

3900 4000

III-60-126/2000
.686352.104-05

RIP

126

73

2000 230

550

3150 4000 172 5,7e

III-60-126/2000
.686352.104-06

RIP

126

73

2000 230

550

3150 4000 182 5,7e

III-60-126/2000
.686352.106

RIP

126

73

2000 230

III-60-126/2000
.686352.107

RIP

126

73

2000 230

550

3150 1600 125

7e

III-90-126/2500
.686352.207

RIP

126

76

2500 230

550

3150 4000

75

7e

III-60-126/2000
.686352.107-01

RIP

126

73

2000 230

550

3150 1600 130

7e

III-90-126/2500
.686352.207-01

RIP

126

76

2500 230

550

3150 4000

78

7e

III-60-126/2000
.686352.150

RIP

126

2000

IV-90-126/1250
.686352.208

RIP

126

1250

III-90-126/800
.686352.248

RIP

126

550

3150 3150

40

5,7

Test cantilever load, N

Creepage distance, mm

2000 230

Lightning impulse
1.2/50 s

73

Switching impulse
250 /2500 s

126

1 minute, 50 Hz

RIP

Rated voltage, kV

III-90-126/2000
.686352.204

Bushing type
Drawing No.

Type of internal insulation

Rated current, A

85

Phase to earth voltage, kV

Weight, kg

Test voltage, kV

126 kV bushings (continuation)

TOP VIEW
Enlarged

12

76

800

230

92

94

95

5,7e

5,7e

5,7e

Overall, fitting and connecting dimensions of high voltage bushings.

L1

L2

L3

arcing
distance
transformer tap
length
housing/shield
diameter
max.
passthrough

length of bottom
part
current transformer length
height of central
flange

Bushing type
Drawing No.

length of bushing

Dimensions, mm

L4

L5

D3

Bottom
shield

Mounting flange*

D1

D2

d
nholes

Pulled  throungh type


connection

L6

D4

d1 d2
n1holes

d3

d4

III-90-126/2000
.686352.204

2210 720

400

1045 1890 220 165 420 380 22/12

60

165

32/4 89

III-60-126/2000
.686352.104-01

2575 1020 400

960 2220 260 165 420 380 22/12

60

165

32/4 89

III-90-126/2000
.686352.204-01

2510 1020 400

1045 2190 220 165 420 380 22/12

60

165

32/4 89

IV-60-126/2000
.686352.104-02

2620 720

400

1305 2265 260 165 420 380 22/12

60

165

32/4 89

IV-90-126/2000
.686352.204-02

2460 720

400

1295 2140 220 165 420 380 22/12

60

165

32/4 89

IV-60-126/2000
.686352.104-03

2920 1020 400

1305 2565 260 165 420 380 22/12

60

165

32/4 89

IV-90-126/2000
.686352.204-03

2760 1020 400

1295 2440 220 165 420 380 22/12

60

165

32/4 89

IV-60-126/2000
.686352.104-04

2670 770

400

1305 2315 260 165 420 380 22/12

60

165

32/4 89

IV-90-126/2000
.686352.204-04

2510 770

400

1295 2190 220 165 420 380 22/12

60

165

32/4 89

III-60-126/2000
.686352.104-05

2575 1020 400

960 2220 260 165 528 480 24/9

60

165

32/4 89

III-60-126/2000
.686352.104-06

2575 1020 400

960 2220 260 165 690 650 24/12

60

165

32/4 89

III-60-126/2000
.686352.106
III-60-126/2000
.686352.107

2422 925

300 125 1000

105 290 250 15/8 25

210 190

III-90-126/2500
.686352.207

2360 925

300

1055

105 290 250 15/8

210 190

III-60-126/2000
.686352.107-01

2515 1020 500 125 1000

105 290 250 15/8 25

210 190

III-90-126/2500
.686352.207-01

2455 1020 500

1055

105 290 250 15/8

210 190

2175 805

1055 1915 148 106 400 350 24/6

60

30

III-60-126/2000
.686352.150
IV-90-126/1250
.686352.208
III-90-126/800
.686352.248

400

* Connecting dimensions of the mounting flange may be modified according to Customer's requirements.

120

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

126 kV bushings

13

Table 2. Part 4 of 7

Technical data of high voltage bushings.

1 minute, 50 Hz

Switching impulse
250 /2500 s

630

275

650

4495 3150 190

III-60-172/800
.686352.109

RIP

172

100

800

275

650

3900 1250 190 5,7

III-60-172/800
.686352.109-01

RIP

172

100

800

275

650

3900 1250 195 5,7

III-90-172/800
.686352.209

RIP

172

104

800

275

550

4250 4000 100 5,7

III-60-172/1000
.686352.111

RIP

172

104

1000 275

650

4250 4000 265 5,7c

III-60-172/1000
.686352.111-01

RIP

172

104

1000 275

650

4250 4000 255 5,7c

III-60-172/1000
.686352.112

RIP

172

104

1000 275

650

4250 4000 220 5,7c

III-60-172/2000
.686352.110

RIP

172

104

2000 275

650

4320 5000 280 5,7e

III-90-172/2000
.686352.210

RIP

172

104

2000 275

650

4250 5000 160 5,7e

III-60-252/1000
.686353.115

RIP

252

153

1000 460

1050 6300 1600 292 5,7b

III-60-252/2000
.686353.114

RIP

252

146

2000 460

1050 6300 5000 455 5,7e

III-90-252/2000
.686353.214

RIP

252

146

2000 460

1050 6300 5000 270 5,7e

III-60-252/2000
.686353.113

RIP

252

146

2000 460

1050 6300 4000 400 5,7e

III-90-252/2000
.686353.213

RIP

252

146

2000 460

1050 6300 5000 230 5,7e

IV-90-252/2000
.686353.213-02

RIP

252

146

2000 460

1050 7900 5000 255 5,7e

III-60-252/2000
.686353.113-01

RIP

252

146

2000 460

1050 6300 4000 427 5,7e

III-90-252/2000
.686353.213-01

RIP

252

146

2000 460

1050 6300 5000 250 5,7e

Weight, kg

Rated current, A

84

Test cantilever load, N

Phase to earth voltage, kV

145

Creepage distance, mm

Rated voltage, kV

RIP

Bushing type
Drawing No.

Lightning impulse
1.2/50 s

Type of internal insulation

Connection type, figure No.

Test voltage, kV

145 kV bushings
IV-60-145/630
.686352.166

172 kV bushings

252 kV bushings

TOP VIEW
Enlarged

14

Overall, fitting and connecting dimensions of high voltage bushings.

L1

L2

L3

arcing
distance
transformer tap
length
housing/shield
diameter
max.
passthrough

length of bottom
part
current transformer length
height of central
flange

Bushing type
Drawing No.

length of bushing

Dimensions, mm

L4

L5

D3

Bottom
shield

Mounting flange*

D1

D2

d
nholes

L6

D4

Pulled  throungh type


connection

d1 d2
n1holes

d3

d4

145 kV bushings
IV-60-145/630
.686352.166

2640 800

300

1380 2385 260 165 350 310 16/12

56

70

130

30

III-60-172/800
.686352.109

2695 850

300

1363 2435 260 165 350 310 22/12

30

56

70

130

30

III-60-172/800
.686352.109-01

2695 850

400

1363 2435 260 165 400 350 24/6

30

56

70

130

30

III-90-172/800
.686352.209

2575 850

300

1400 2265 220 165 350 310 22/12

30

56

70

130

30

III-60-172/1000
.686352.111

2920 1075 300

1380 2670 260 165 670 620 24/9

19/4 56

70

130

40

III-60-172/1000
.686352.111-01

2920 1075 450

1380 2670 260 165 530 480 24/9

19/4 56

70

130

40

III-60-172/1000
.686352.112

3030 1180 300

1325 2770 260 165 670 620 24/9

28/3

85

130

40

III-60-172/2000
.686352.110

3125 1000 500

1475 2765 300 198 420 380 22/12

60

165

32/4 89

III-90-172/2000
.686352.210

2960 1000 500

1450 2460 270 198 420 380 22/12

60

165

32/4 89

III-60-252/1000
.686353.115

3805 1025 400

1960 3490

450 400 22/12

60

165

56

III-60-252/2000
.686353.114

4800 1905 1140

2025 4470 276 198 760 720 24/16

90

251

32/4 89

III-90-252/2000
.686353.214

4530 1905 1140

2100 4025

760 720 24/16

91

251

32/4 89

III-60-252/2000
.686353.113

4275 1380 600

2025 3945 276 198 600 560 24/16

90

251

32/4 89

III-90-252/2000
.686353.213

4005 1380 600

2100 3500

600 560 24/16

91

251

32/4 89

IV-90-252/2000
.686353.213-02

4505 1380 700

2600 4000

600 560 24/16

91

251

32/4 89

III-60-252/2000
.686353.113-01

4275 1380 600

2025 3765 276 198 760 720 24/16

90

251

32/4 89

III-90-252/2000
.686353.213-01

4005 1380 600

2100 3500

91

251

32/4 89

760 720 24/16

* Connecting dimensions of the mounting flange may be modified according to Customer's requirements.

30

15

H i g h vo l t a g e b u s h i n g s f o r p owe r t ra n s f o r m e r s a n d re a c t o r s

252 kV bushings

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

172 kV bushings

Table 2. Part 5 of 7

Technical data of high voltage bushings.

Connection type, figure No.

Weight, kg

Test cantilever load, N

Creepage distance, mm

Lightning impulse
1.2/50 s

Switching impulse
250 /2500 s

1 minute, 50 Hz

Rated current, A

Phase to earth voltage, kV

Rated voltage, kV

Bushing type
Drawing No.

Type of internal insulation

Test voltage, kV

252 kV bushings (continuation)

TOP VIEW
Enlarged

III-60-252/2000
.686353.116

RIP

252

153

2000 460

1050 6300 2500 370

7c

III-90-252/2000
.686353.216

RIP

252

146

2000 460

1050 6300 5000 190

7c

III-60-252/2000
.686353.117

RIP

252

153

2000 460

1050 6300 5000 390 5,7e

III-60-252/2000
.686353.118

RIP

252

146

2000 460

1050 6300 4000 320 6,7b

III-60-252/2000
.686353.119

RIP

252

146

2000 460

1050 6300 4000 310 6,7e

III-60-252/2000
.686353.119-01

RIP

252

146

2000 460

1050 6300 4000 315 6,7e

IV-60-252/2000
.686353.119-02

RIP

252

146

2000 460

1050 7900 4000 365 6,7e

III-60-252/2000
.686353.119-03

RIP

252

146

2000 460

1050 6300 4000 320 6,7e

III-60-252/2000
.686353.122

RIP

252

III-60-252/3150
.686353.153

RIP

252

152

3150 425

950

III-60-252/2000
.686353.164

RIP

252

146

2000 460

1050 6300 4000 310 6,7c

III-60-252/2000
.686353.164-01

RIP

252

146

2000 460

1050 6300 4000 315 6,7c

IV-60-252/2000
.686353.164-02

RIP

252

146

2000 460

1050 7900 4000 365 6,7c

III-60-252/2000
.686353.164-03

RIP

252

146

2000 460

1050 6300 4000 320 6,7c

IV-90-252/1600
.686353.223

RIP

252

1600

IV-90-252/800
.686353.249

RIP

252

146

800

III-60-363/1000
.686354.171

RIP

363

210

1000 510

950 1175 9050 2500 650 5,7b

III-90-363/1000
.686354.224

RIP

363

210

1000 510

950 1175 9050 2500 960 5,7b

2000

460

6300 4000 490

1050 7900 4000 282 5,7b

363 kV bushings

16
4

Overall, fitting and connecting dimensions of high voltage bushings.

L1

L2

L3

arcing
distance
transformer tap
length
housing/shield
diameter
max.
passthrough

length of bottom
part
current transformer length
height of central
flange

Bushing type
Drawing No.

length of bushing

Dimensions, mm

L4

L5

D3

Bottom
shield

Mounting flange*

D1

D2

d
nholes

L6

D4

Pulled  throungh type


connection

d1 d2
n1holes

d3

d4

4155 1535 600

1960

165 670 620 24/16

III-90-252/2000
.686353.216

4025 1535 600

2145

225 165 670 620 24/16

III-60-252/2000
.686353.117

3965 1070 400

2025 3625 276 198 600 560 24/16

III-60-252/2000
.686353.118

3845 1225 300

1960

238 165 450 400 22/12

230 239

III-60-252/2000
.686353.119

3760 1030 300

1960

238 165 450 400 22/12 25

230 240

III-60-252/2000
.686353.119-01

3860 1130 400

1960

238 165 450 400 22/12 25

IV-60-252/2000
.686353.119-02

4260 1130 400

2360

III-60-252/2000
.686353.119-03

3960 1230 500

1960

III-60-252/3150
.686353.153

4330 1380 710

III-60-252/2000
.686353.164

175

70

175

90

251

32/4 89

230 240

238 165 450 400 22/12 25

230 240

238 165 450 400 22/12 25

230 240

2025

276 198 400 350 22/8

230 240

3655 1030 300

1960

238 165 450 400 22/12 25

230 240

III-60-252/2000
.686353.164-01

3755 1130 400

1960

238 165 450 400 22/12 25

230 240

IV-60-252/2000
.686353.164-02

4155 1130 400

2360

238 165 450 400 22/12 25

230 240

III-60-252/2000
.686353.164-03

3855 1230 500

1960

238 165 450 400 22/12 25

230 240

4990 1880 1045

2600 4690 270 210 550 500 24/12

120 251

30

89

III-60-363/1000
.686354.171

5815 2160 600

2770 5220 296 225 818 770 24/16

91

251

30/2 89

III-90-363/1000
.686354.224

5673 2160 600

2970 5220 270 240 818 770 24/16

91

251

30/2 89

III-60-252/2000
.686353.122

IV-90-252/1600
.686353.223
IV-90-252/800
.686353.249

363 kV bushings

* Connecting dimensions of the mounting flange may be modified according to Customer's requirements.

17

H i g h vo l t a g e b u s h i n g s f o r p owe r t ra n s f o r m e r s a n d re a c t o r s

III-60-252/2000
.686353.116

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

252 kV bushings

Table 2. Part 6 of 7

Technical data of high voltage bushings.

Connection type, figure No.

Weight, kg

Test cantilever load, N

Creepage distance, mm

Lightning impulse
1.2/50 s

Switching impulse
250 /2500 s

1 minute, 50 Hz

Rated current, A

Phase to earth voltage, kV

Rated voltage, kV

Bushing type
Drawing No.

Type of internal insulation

Test voltage, kV

363 kV bushings(continuation)
III-90-363/1000|
.686353.224-01

RIP

363

210

1000 510

950 1175 9050 2500 320 5,7b

III-60-363/2500
.686354.125

RIP

363

210

2500 510

950 1175 8000 3150 620 5,7d

III-90-363/2500
.686354.225

RIP

363

210

2500 510

950 1175 9000 3150 300 5,7e

III-60-363/1250
.686354.147

RIP

363

210

1250 510

950 1175 9050 2500 600 6,7

III-60-363/1250
.686354.147-01

RIP

363

210

1250 510

950 1175 9050 2500 612 6,7

III-60-550/800
.686355.128

RIP

550

334

800

680

1230 1550 13150 4000 1200 7

III-60-550/1600
.686355.173

RIP

550

300

1600 680

1230 1550 13150 5000 1900 7e

III-60-550/630
.686355.173-01

RIP

550

303

630

1230 1550 13150 3150 1400 7e

III-60-550/2500
.686355.172

RIP

550

303

2500 680

1230 1550 13150 2500 1230 5,7e

III-60-550/2500
.686355.172-01

RIP

550

303

2500 680

1230 1550 13150 2500 1230 5,7e

III-30-550/315
.686355.129

RIP

550

303

315

680

1230 1550 13735 2500 1150 5,7e

III-60-550/1250
.686355.146

RIP

550

334

1250 680

1230 1550 15125 4000 1200 5,7e

III-60-550/1251
.686355.146-01

RIP

550

334

1250 680

1230 1550 15125 4000 1180 5,7e

III-60-550/1600
.686355.146-02

RIP

550

334

1600 680

1230 1550 15125 4000 1200 5,7e

RIP

600

OIP

800

550 kV bushings

TOP VIEW
Enlarged

680

600 kV bushings
III-90-600/800
.686355.262

800

800 kV bushings
II-30-750/1000
.686345.011

18
4

462

1000 975

1550 2400 15750 2500 2750 5,7e

Overall, fitting and connecting dimensions of high voltage bushings.

L1

L2

L3

arcing
distance
transformer tap
length
housing/shield
diameter
max.
passthrough

length of bottom
part
current transformer length
height of central
flange

Bushing type
Drawing No.

length of bushing

Dimensions, mm

L4

L5

D3

Bottom
shield

Mounting flange*

D1

D2

d
nholes

Pulled  throungh type


connection

L6

D4

d1 d2
n1holes

d3

d4

363 kV bushings
III-90-363/1000
.686353.224-01

5000 1490 600

2965 4550

225 450 400 22/12

91

251

30/2 89

III-60-363/2500
.686354.125

5290 1620 600

2770 4970 296 225 600 560 24/16

91

251

32/2 89

III-90-363/2500
.686354.225

5140 1615 600

2970 4820 270 240 600 560 24/16

90

250

32/4 89

III-60-363/1250
.686354.147

4685 1155 300

2770

296 225 450 400 22/12

230 239

III-60-363/1250
.686354.147-01

4885 1355 500

2770

296 225 450 400 22/12

230 239

III-60-550/800
.686355.128

6462 1790 600

3670

296 275 720 660 24/12

330 296

III-60-550/1600
.686355.173

7855 2750 1000

3955

1200 1130 24/16

277 490

III-60-550/630
.686355.173-01

8665 3850 2000

3670

296 275 1200 1130 24/16

490

III-60-550/2500
.686355.172

7470 2600 1000

3670 6520 296 275 1200 1130 24/16

175 282

28/4 89

III-60-550/2500
.686355.172-01

7540 2670 1000

3670 6520 296 275 1200 1130 24/16

280 400

28/4 89

III-30-550/315
.686355.129

7330 2205 700

3970 6625 296 320 1200 1130 24/16

III-60-550/1250
.686355.146

7515 2080 900 237 4240 6980 296 275 720 660 24/12 37

190 290

20/4 69

III-60-550/1251
.686355.146-01

7215 1780 600 237 4240 6680 296 275 720 660 24/12 37

190 290

20/4 69

III-60-550/1600
.686355.146-02

7515 2080 900 237 4240 6980 296 275 720 660 24/12 37

190 290

24/4 69

9430 2720 810 160 4900 7690 580 590 820 740 24/12 35

280 400

28/3 69

600 kV bushings
III-90-600/800
.686355.262

800 kV bushings
II-30-750/1000
.686345.011

* Connecting dimensions of the mounting flange may be modified according to Customer's requirements.

19
4

H i g h vo l t a g e b u s h i n g s f o r p owe r t ra n s f o r m e r s a n d re a c t o r s

30

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

550 kV bushings

Table 2. Part 7 of 7

Technical data of high voltage bushings.

Connection type, figure No.

Weight, kg

Test cantilever load, N

Creepage distance, mm

Lightning impulse
1.2/50 s

Switching impulse
250 /2500 s

1 minute, 50 Hz

Rated current, A

Phase to earth voltage, kV

Rated voltage, kV

Bushing type
Drawing No.

Type of internal insulation

Test voltage, kV

800 kV bushings (continuation)


II-30-750/1000
.686345.009

OIP

800

455

1000 975

1550 2400 15750 2500 2700 5,7e

II-30-750/1000
.686345.011-01

OIP

800

462

1000 975

1550 2400 15750 2500 2840 5,7e

II-30-750/1000
.686345.009-01

OIP

800

455

1000 975

1550 2400 15750 2500 2790 5,7e

II-30-750/1250
.686345.010

OIP

800

462

1250 950

1550 2400 17700 2500 2800 6b,7d

II-30-750/1250
.686345.013

OIP

800

462

1250 975

1550 2400 17700 2500 2580 6b,7d

II-30-800/1000
.686346.145

OIP

800

1000

II-30-800/1000
.686346.145-01

OIP

800

1000

II-60-800/315
.686356.165

RIP

800

486

315

950

1550 2100 15750 4000 2110 5,7e

1200 kV bushings
-20-1150/1250
2.800.119

TOP VIEW
Enlarged

20

OIP 1200 694

1250 1150 1900 2700 18000 2500 11690 5,7d

Overall, fitting and connecting dimensions of high voltage bushings.

L1

L2

L3

arcing
distance
transformer tap
length
housing/shield
diameter
max.
passthrough

length of bottom
part
current transformer length
height of central
flange

Bushing type
Drawing No.

length of bushing

Dimensions, mm

L4

L5

D3

Bottom
shield

Mounting flange*

D1

D2

d
nholes

L6

D4

Pulled  throungh type


connection

d1 d2
n1holes

d3

d4

800 kV bushings
II-30-750/1000
.686345.009

9430 2720 810 160 4900 7690 580 590 820 740 24/12 35

280 400

28/3 69

II-30-750/1000
.686345.011-01

9430 2720 810 160 4900 7690 580 590 1200 1130 24/16 35

280 400

28/3 69

II-30-750/1000
.686345.009-01

9430 2720 810 160 4900 7690 580 590 1200 1130 24/16 35

280 400

28/3 69

II-30-750/1250
.686345.010

10080 2720 810 160 5525

580 590 820 740 32/12 35

280 400

II-30-750/1250
.686345.013

9640 2410 810 160 5525

580 590 820 740 32/12 35

280 400

30

72

II-30-800/1000
.686346.145

8515 2605 750

4900 7910 415 405 1200 1130 24/16

1200 kV bushings
-20-1150/1250
2.800.119

11815 2855 800 230 7500 11063 530 850 1200 1130 25/16 31

* Connecting dimensions of the mounting flange may be modified according to Customer's requirements.

28/4 85

21
4

H i g h vo l t a g e b u s h i n g s f o r p owe r t ra n s f o r m e r s a n d re a c t o r s

II-60-800/315
.686356.165

H I G H VO LTAG E B U S H I N G S F O R P OW E R T R AN S F O R M E R S AN D R E AC TO R S

II-30-800/1000
.686346.145-01

Testing and operation

Interchangeability

Every type of bushing passed acceptance tests for compliance with all requirements of State Standard GOST 1069381
and Standard IEC 60137.

The range of products being manufactured includes not only the bushings currently mounted on the newly made transformers and reactors, but also those
designed instead of the bushings manufactured previously. In this case, adequacy of the submerged bushing parts and
the length of the pulledthrough tap, as
well as fitting dimensions of the mounting
flange, are observed; if necessary, this is
coordinated with the transformer and
reactor manufacturers.

Every
manufactured
bushing
is
subjected to handover tests for the purpose
of checking its compliance with the requirements in regard of the type and quality of
manufacture, including test measurement of
partial discharge level and tg of the insulation, according to the mentioned documents.
The advantage of the bushings with solid
insulation as compared to oil impregnated
paper insulation is that oil contained in them
is not intended for active insulation.
Therefore, they need no regular condition
monitoring. Technical maintenance requires
only periodic (once in 4 years) measurement
of tg of the bushing insulation.

WEIGHT

DATE OF MANUFACTURE

DRAWING NUMBER

BUSHING TYPE

SERIAL NUMBER

NUMBER OF TECHNICAL SPECIFICATIONS


OR STATE STANDARD

Figure 9

22

Nameplate.

NOTES

23

NOTES

24

HIGH QUALITY OF OUR PRODUCTS ENSURE LONGTERM SAFE AND RELIABLE OPERATION
OF EQUIPMENT AT ELECTRIC POWER SUBSTATIONS UNDER ANY CONDITIONS AT THE MOST
IMPORTANT OBJECTS

110 kV/630 A bushings on the 40 MVA power transformer.

220 kV/2000 A bushings on the 200 MVA power transformer.

750 kV bushings on the shunt reactors 110 MVA.

330 kV bushings on the 125 MVA power transformer.

Massa Ltd. Company


77 Lenina st., Pavlovskaya Sloboda village, Istra district,
Moscow region 143581, Russia
Tel.: +7 (495) 727 3311
Fax: +7 (495) 727 3320
E-mail: aleksey.gavrilov@mosizolyator.ru
andrey.shornikov@mosizolyator.ru
www. mosizolyator.com

Izolyator Plant reserves the right to make changes in the subsequent publications of the catalogue
according to new developments, as well as Customers remarks and requests.