You are on page 1of 22

TM

NAFLON Bellows
Fluoropolymer Universal Expansion Joint

TM

NAFLON Bellows
NAFLON bellows are mainly used to absorb the thermal expansion and
contraction of pipelines.
When designing piping systems for various industrial facilities, it is
necessary to fully consider the absorption of the thermal expansion or
contraction of pipe lines, correction of the misalignment between
equipment and a pipe axis due to aging, and the absorption of
vibrations and noises produced between pipelines and vibration
sources including pumps.
Although metal bellows and rubber bellows have been commonly used
as expansion pipe joints for those purposes, these joints are not
satisfactory in terms of corrosion proofing and durability, especially in
the presence of strong corrosive acids, alkalis, or chlorinated solvents.
NAFLON bellows, which we introduce here, are versatile expansion
joints manufactured with fluororesin (PTFE or PFA) which has many
excellent characteristics including chemical resistance and heat
resistance.
Fluororesin has corrosion resistance to almost all chemicals and has
features such as nonadhesiveness, a low friction coefficient, and
weather resistance, which other plastics do not have. In addition, it has
outstanding durability against repeated stress.
Taking advantage of these strong points of fluoropolymers, we provide
NAFLON bellows in many types including the five basic types of
TOMBO No. 9060 through 9064, which enable you to freely select the
proper type according to your installation method and operating
conditions.
NICHIAS's NAFLON Bellows will deliver high performance as an
expansion joint for a long time in processes involving strong corrosive
liquids, thus assuring trouble-free operation.
* When you use or select our products, please consult our sales or technical
department for detailed information after filling out your operation conditions
in theInquiry Formon page 24.
TOMBO is a registered trademark of NICHIAS Corporation.
All brand names and product names are trademarks or registered trademarks
of NICHIAS Corporation.

Table of Contents
General Features /
Product Types and Selection Guideline

General Features

23

TOMBO No.9061-S

45

TOMBO No.9061-GY

67

TOMBO No.9061-HW

Because of the nonadhesive


property of fluroresin, when handling
a sticky liquid, internal washing can
be performed easily and the amount
of time for post processing can be
reduced.

This product has excellent


corrosion resistance to almost
all chemicals including acids,
alkalis, solvents, and liquid
mixtures of these chemicals, and
undergoes no change.

Product No.

TOMBO No.9060

Product Name

NAFLON PTFE Expansion Joint


(Machined Type)
The bellows section is
machined from a thick
wall PTFE pipe and the
flanges are attached to
both sides.

Product Structure

Selection Guideline
TOMBO No.9061-S,SV TOMBO No.9061-GY,GYV TOMBO No.9061-HW TOMBO No.9062-S,L-SV TOMBO No.9063-S,L-SV

1011

TOMBO No.9062-L

1213

TOMBO No.9063-S

1415

TOMBO No.9063-L

1617

TOMBO No.9064

1819

TOMBO No.9063-P,9063-B

20

TOMBO No.9061-SV,9062-SV,9063-SV

21

Technical Data / Vacuum proofing


and operating temperature limit
Technical Data / Variations in the amount of contraction
of the vacuum-proof products of the vacuum-proof products
Technical Data / Relation between the amount of
expansion and contraction and axial displacement

22
22

Materials

Dimensions

Bellows

PTFE

Reinforcing Ring

PTFE tube is formed to


U-shaped convolution
valleys, and flanges are
attached to both sides.
This product is good for
applications requiring
displacement.

23

Inquiry Form for Information of NAFLONTM Bellows

24

Reference Data / Table showing pipe expansion


and conversion diagram showing degree of vacuum

25

Examples of Installation

26

Related Products / Piping System

27

Cautions for Handling

28

Warnings and Precautions for Product Handling

29

PTFE

The stainless steel of


the 9061-S reinforcing
rings is replaced with
FRP.
This product is a
suitable solution against
corrosion of stainless
steel reinforcing rings
when used with chloric
or muriatic liquids.

PTFE

The bellows section of


9061-S is thickened to
improve pressure
resistance.
This product can be
used for vacuum
applications without
vacuum support rings.

PTFE

SUS thin wall pipe


shrouded with a PTFE
tube is formed to Ushaped convolution
valleys, and flanges are
attached to both sides.
This product is good for
applications requiring
heat resistance and
pressure resistance.
In addition, the 9062-L
type with a long face-toface length is also
available.

PTFE tube is formed to Ushaped convolution valleys,


and flanges are attached to
both sides. Using U-shaped
control rings, heat
resistance and pressure
resistance are improved.
This product is good for
applications requiring heat
resistance and
displacement.
In addition, the 9063-L type
with a long face-to-face
length is also available.

PFA tube is formed to


U-shaped convolution
valleys, and flanges are
attached to both sides.
A semitransparent
surface makes it
possible to visually
confirm liquid running
inside.

PTFE+SUS304

PTFE

PFA

SUS304

FRP

SUS304

AC7A

SUS304

Size

20400A

25600A

25600A

25150A

50600A

50500A9063-L:50400A

50300A

No. of
convolutions

3 convolutions,
7 convolutions

3 convolutions,
5 convolutions

3 convolutions,
5 convolutions

3 convolutions

50 - 100A: 5 convolutions,
8 convolutions, 10 convolutions
125 - 350A: 3 convolutions, 5 convolutions,
8 convolutions, 10 convolutions
400 - 600A: 3 convolutions,
5 convolutions, 7 convolutions

3 convolutions,
5 convolutions

2 convolutions,
3 convolutions,
5 convolutions

120

150

150

150

200

3 convolutions: 200
5 convolutions: 180

Maximum Service Temperature

23

Technical Data / Reference value of pitch and the


amount of expansion and contraction per convolution

TOMBO No.9064

NAFLON PTFE Expansion Joint NAFLON PTFE Expansion Joint NAFLON PTFE Expansion Joint NAFLON PTFE Expansion Joint
NAFLON PTFE Expansion Joint (Reinforcing Ring FRP Type)
NAFLON PFA Expansion Joint
(Heavy Wall Type)
(Heat Resistance Type)
(Stainless Steel Shroudins Type)

89

TOMBO No.9062-S

Fluororesin is so excellent in
weather resistance that it exhibits
almost no aging and degradation
symptoms, which makes this
product suitable for long-term use.

High nonadhesiveness makes


internal washing easy.

Excellent chemical
resistance

Product Types and

Tolerant for long-term


storage and use

Since the main body of the bellows


is manufactured from fluororesin,
this product is highly flexible and
has excellent durability against
fatigue from flexing.

This product can be used for a very


wide range of temperatures, from
-20 degrees to +200 degrees. In
addition, this product can be used
continuously for long periods of
time.

TOMBO No.9060

Excellent elasticity

Wide range of service


temperatures

Not Available

-SV type (using support rings)


(200A - 600A x 3 convolutions)

-GYV type (using support rings)


(200A - 600A x 3 convolutions)

Available

Heat Resistance

Comparison Pressure Resistance


of
Features Softness
Displacement

Vacuum Specifications

* Regend : Aexelent, Bgood, Cstandard.


* When you make a selection, please consult our

-SV and -LV types (using support rings) -SV and -LV types (using support rings)
(3 convolutions and 5 convolutions only) (3 convolutions and 5 convolutions only)

150
Available
(2 convolutions and
3 convolutions only)

* This evaluation is determined based on comparisons among the bellows products of our company.
sales or technical department for detailed information after filling out your operation conditions in theInquiry Formprovided on page 24.

TOMBO No.9060
TM

NAFLON PTFE Expansion Joint (Machined Type)


Standard dimensions

Construction
Parts No.

Name

Standard Specifications

Bellows

PTFE

Flange Corresponding to JIS 10K

FCD450 (partially SS400)


or SUS304

Backup Gasket

Non asbestos Joint Sheet

Limit Bolt

SS400 (Unichro-plated)

U Nut with Cap

SS400 (Unichro-plated)

Stopper

SS400 (Unichro-plated)

Since the TOMBO No. 9060 PTFE Bellows machined type


expansion joints are manufactured using machining processing, it
is possible to freely form the shape of the bellows convolutions.
Please consult us when special shapes are required.

Axial
Face-to-face Amount of expansion
and contraction displacement
length
mm
mm
mm

Product code

Diameter
nominal
AB

9060 203
9060 207

20
3/4

38
52

2
5

3
7

19

39

9060 253
9060 257

25
1

40
57

4
7

3
7

28

51

9060 403
9060 407

40
11/2

45
64

5
10

3
7

42

69

9060 503
9060 507

50
2

45
65

5
11

3
7

54

83

9060 653
9060 657

65
21/2

50
71

6
13

3
7

68

99

9060 803
9060 807

80
3

50
72

6
14

3
7

82

115

90601003
90601007

100
4

53
77

6
18

3
7

101

140

90601253
90601257

125
5

59
88

7
18

3
7

127

167

90601503
90601507

150
6

60
88

8
18

3
7

156

197

90602003
90602007

200
8

62
93

10
23

3
7

200

247

90602503
90602507

250
10

66
100

10
24

3
7

255

305

90603003
90603007

300
12

74
105

10
25

3
7

303

354

90603503
90603507

350
14

79
110

11
26

3
7

340

395

90604003
90604007

400
16

87
118

14
31

3
7

393

453

Dimension of expansion partsmm


Numbers of standard
convolutions

Inner diameter d Flared Diameter D

(Examples)

The holes for the flange bolts are tapped holes in the standard
specifications.
JIS 5K flanges and ANSI 150LB flanges can be manufactured
upon request.
Bellows with a number of convolutions other than those listed
in the dimensions on the next page can be manufactured upon
request.
For nominal diameters of 400A or more, please contact us.
The Fire Service Law cannot be applied.

Operating Pressure
TOMBO No.9060
Max Pressure Resistance (MPa)

0.8

3 convolutions

0.7

7 convolutions

0.6
0.5
0.4 20A 50A
0.3
0.2
0.1

65A 100A

20A 50A

125A 250A

25

65A 100A
125A 250A
50

100

120

150

The operating pressure table shows the values for the


standard face-to-face lengths. When using the product at the
maximum expansion and the maximum displacement, use the
values obtained by multiplying the following coefficients.
At the maximum expansion: 0.7
At the maximum displacement: 0.5
For the operating pressures for sizes of 250A (10B) or more,
please consult us.
Refer to page 23 for cases where expansion or contraction and
axis displacement occur at the same time.
The maximum service temperature is 120.

Temperature ()

TOMBO No.9061-S
TM

NAFLON PTFE Expansion Joint


Standard dimensions

Construction (25A-300A)

Diameter
nominal
AB

9061S 253
9061S 255

25
1

45
65

10
13

6
13

3
5

25

50

9061S 323
9061S 325

32
11/4

50
70

10
13

6
13

3
5

32

62

9061S 403
9061S 405

40
11/2

50
75

13
15

6
13

3
5

38

73

9061S 503
9061S 505

50
2

70
100

19
25

10
13

3
5

49

92

9061S 653
9061S 655

65
21/2

75
115

19
25

10
13

3
5

63

105

9061S 803
9061S 805

80
3

85
125

19
25

10
13

3
5

73

120

9061S1003
9061S1005

100
4

85
125

19
25

13
16

3
5

97

145

9061S1253
9061S1255

125
5

100
140

20
30
30
40

3
10

3
5

119

175

9061S1503
9061S1505

150
6

100
150

20
30
30
45

3
10

3
5

145

205

9061S2003
9061S2005

200
8

110
155

20
30
35
50

3
10

3
5

196

255

9061S2503
9061S2505

250
10

120
175

15
35
20
60

3
10

3
5

244

315

9061S3003
9061S3005

300
12

120
175

15
35
20
60

3
10

3
5

292

360

Operating Pressure

9061S3503
9061S3505

350
14

130
190

15
40
20
70

3
10

3
5

322

405

TOMBO No.9061-S with 3 Convolutions

9061S4003
9061S4005

400
16

150
225

3
10

3
5

372

465

9061S4503
9061S4505

450
18

155
235

3
10

3
5

422

520

9061S5003
9061S5005

500
20

160
240

3
10

3
5

472

575

9061S5503
9061S5505

550
22

175
265

3
10

3
5

522

630

9061S6003
9061S6005

600
24

175
265

3
10

3
5

572

680

Name
Bellows

Standard Specifications
PTFE

Flange Corresponding to JIS 10K FCD450


Reinforcing Ring

SUS304

Limit Bolt

SS400 (Unichro-plated)

U Nut

SS400 (Unichro-plated)

Grommet

Chloroprene Rubber

Washer

SS400 (Unichro-plated)

Notes common to the two types of 25A to 300A and 350A to


600A
The holes for the flange bolts are tapped holes in the standard
specifications. However, the holes on both sides are drilled
holes only for the 350A to 600A with 5 convolutions.
The Fire Service Law cannot be applied.
The sizes of the tapped holes are matched to fit the sizes of
the bolts used for JIS 10K flanges.
For vacuum applications, refer to page 21.
The limit bolts are set with the standard face-to-face distance
(L) when shipping. Adjust them within the allowable range
of expansion and contraction, if necessary.
ANSI, other flange standards, and other materials can be
manufactured.

Construction (350A-600A)

Parts No.

1.0
0.8
0.6

20A 100A
125A 150A

200A 250A

0.4
300A 600A

0.2

50

100

150

Temperature ()
The operating pressure table shows the values for the standard
face-to-face lengths. When using the product at the maximum
expansion and the maximum displacement, use the values obtained
by multiplying the following coefficients.
At the maximum expansion: 0.7At the maximum displacement: 0.5

Name

Standard Specifications

Bellows

PTFE

Flange Corresponding to JIS 10K

SS400

Reinforcing Ring

SUS304

Limit Bolt

SS400 (Unichro-plated)

Hexagon Nut

SS400 (Unichro-plated)

Stopper

SS400 (Unichro-plated)

TOMBO No.9061-S with 5 Convolutions


Max Pressure Resistance (MPa)

Max Pressure Resistance (MPa)

1.2

Face-to-face Amount of expansion


Axial
length
and contraction displacement
mm
mm
mm

Product code

Parts No.

0.6
0.5
0.4

20A 100A

125A 250A

0.3
0.2
300A

0.1

50

100

150

15
50
20
80
20
50
25
90
20
50
25
90
20
55
25
100
20
55
25
100

Dimension of expansion partsmm


Numbers of standard
convolutions

Inner diameter d Flared Diameter D

Temperature ()
Refer to page 23 for cases where expansion or contraction and axis
displacement occur at the same time.
The maximum service temperature is 150.

TOMBO No.9061-GY
TM

NAFLON PTFE Expansion Joint (Reinforcing Ring FRP Type)


Standard dimensions

Construction (25A-300A)

Product code

Diameter
nominal
AB

9061GY 253
9061GY 255

25
1

45
65

10
13

6
13

3
5

25

50

9061GY 323
9061GY 325

32
11/4

50
70

10
13

6
13

3
5

32

62

9061GY 403
9061GY 405

40
11/2

50
75

13
15

6
13

3
5

38

73

9061GY 503
9061GY 505

50
2

70
100

19
25

10
13

3
5

49

92

9061GY 653
9061GY 655

65
21/2

75
115

19
25

10
13

3
5

63

105

9061GY 803
9061GY 805

80
3

85
125

19
25

10
13

3
5

73

120

9061GY1003
9061GY1005

100
4

85
125

19
25

13
16

3
5

97

145

9061GY1253
9061GY1255

125
5

100
140

20
30
30
40

3
10

3
5

119

175

9061GY1503
9061GY1505

150
6

100
150

20
30
30
45

3
10

3
5

145

205

9061GY2003
9061GY2005

200
8

110
155

20
30
35
50

3
10

3
5

196

255

9061GY2503
9061GY2505

250
10

120
175

15
35
20
60

3
10

3
5

244

315

9061GY3003
9061GY3005

300
12

120
175

15
35
20
60

3
10

3
5

292

360

Operating Pressure

9061GY3503
9061GY3505

350
14

130
190

15
40
20
70

3
10

3
5

322

405

TOMBO No.9061-GY with 3 Convolutions

9061GY4003
9061GY4005

400
16

150
225

3
10

3
5

372

465

9061GY4503
9061GY4505

450
18

155
235

3
10

3
5

422

520

9061GY5003
9061GY5005

500
20

160
240

3
10

3
5

472

575

9061GY5503
9061GY5505

550
22

175
265

3
10

3
5

522

630

9061GY6003
9061GY6005

600
24

175
265

3
10

3
5

572

680

Parts No.

Name
Bellows

PTFE

Flange Corresponding to JIS 10K

FCD450

Reinforcing Ring

FRP

Limit Bolt

SS400 (Unichro-plated)

U Nut

SS400 (Unichro-plated)

Grommet

Chloroprene Rubber

Washer

SS400 (Unichro-plated)

Notes common to the two types of 25A to 300A and 350A to


600A
The holes for the flange bolts are tapped holes in the standard
specifications. However, the holes on both sides are drilled
holes only for the 350A to 600A with 5 convolutions.
The Fire Service Law cannot be applied.
The sizes of the tapped holes are matched to fit the sizes of
the bolts used for JIS 10K flanges.
For vacuum applications, refer to page 21.
The limit bolts are set with the standard face-to-face distance
(L) when shipping. Adjust them within the allowable range
of expansion and contraction, if necessary.
ANSI, other flange standards, and other materials can be
manufactured.

Construction (350A-600A)

Parts No.

0.8
0.6

20A 100A
125A 150A

200A 250A

0.4
300A 600A

0.2

Standard Specifications

Bellows

PTFE

Flange Corresponding to JIS 10K

SS400

Reinforcing Ring

FRP

Limit Bolt

SS400 (Unichro-plated)

Hexagon Nut

SS400 (Unichro-plated)

Stopper

SS400 (Unichro-plated)

100

150

Temperature ()
The operating pressure table shows the values for the standard
face-to-face lengths. When using the product at the maximum
expansion and the maximum displacement, use the values obtained
by multiplying the following coefficients.
At the maximum expansion: 0.7At the maximum displacement: 0.5

Face-to-face Amount of expansion


Axial
length
and contraction displacement
mm
mm
mm

0.6
0.5
0.4

20A 100A

125A 250A

0.3
0.2
300A

0.1

50

Name

TOMBO No.9061-GY with 5 Convolutions


Max Pressure Resistance (MPa)

Max Pressure Resistance (MPa)

1.2
1.0

Standard Specifications

50

100

150

15
50
20
80
20
50
25
90
20
50
25
90
20
55
25
100
20
55
25
100

Dimension of expansion partsmm


Numbers of standard
convolutions

Inner diameter d Flared Diameter D

Temperature ()
Refer to page 23 for cases where expansion or contraction and axis
displacement occur at the same time.
The maximum service temperature is 150.

TOMBO No.9061-HW
TM

NAFLON PTFE Expansion Joint (Heavy Wall Type)


Construction

Standard dimensions
Parts No.

Name

Standard Specifications

Bellows

PTFE

Flange Corresponding to JIS 10K

FCD450

Reinforcing Ring

SUS304

Limit Bolt

SS400 (Unichro-plated)

U Nut

SS400 (Unichro-plated)

Grommet

Chloroprene Rubber

Washer

SS400 (Unichro-plated)

The holes for the flange bolts are tapped holes in the standard
specifications. The sizes of the tapped holes are matched to fit
the sizes of the bolts used for JIS 10K flanges.
The Fire Service Law cannot be applied.
For the maximum service temperature, refer to page 22.
The limit bolts are set with the standard face-to-face distance
(L) when shipping. Adjust them within the allowable range of
expansion and contraction, if necessary.
ANSI, other flange standards, and other materials can be
manufactured.

Product code

Diameter
nominal
AB

9061HW 253

25A
1

50

10

24

50

9061HW 323

32A
11/4

50

10
5

32

62

9061HW 403

40A
11/2

55

10

36

73

9061HW 503

50A
2

70

15

49

92

9061HW 653

65A
21/2

80

10

63

105

9061HW 803

80A
3

100

25
20

74

120

9061HW1003

100A
4

100

25
20

12

95

145

9061HW1253

125A
5

100

25
15

12

118

175

9061HW1503

150A
6

100

25
10

12

144

205

Operating Pressure
TOMBO No.9061-HW with 3 Convolutions
Max Pressure Resistance (MPa)

1.0

Face-to-face Amount of expansion


Axial
length
and contraction displacement
mm
mm
mm

Dimension of expansion partsmm


Numbers of standard
convolutions

Inner diameter d Flared Diameter D

The operating pressure table shows the values for the


standard face-to-face lengths. When using the product at the
maximum expansion and the maximum displacement, use the
values obtained by multiplying the following coefficients.
At the maximum expansion: 0.7
At the maximum displacement: 0.5
Refer to page 23 for cases where expansion or contraction and
axis displacement occur at the same time.
The maximum service temperature is 150.

25100A

125150A
0.5

0
50

100

150

Temperature ()

TOMBO No.9062-S
TM

NAFLON PTFE Expansion Joint (Stainless Steel Shrouding Type)


Standard dimensions

Construction
Parts No.

Name

Standard Specifications

Bellows

PTFE

Bellows

SUS304

Flange Corresponding to JIS 10K

SS400

Shipping Bolt

SS400

Nut

SS400

The JIS 10K flange is standard, but the ANSI 150LB type is
also available.
The holes for the flange bolts are tapped holes.
Products with a number of convolutions other than the ones in
the standard can be manufactured.
In the event of displacement caused by an earthquake, the
maximum allowable displacement is obtained by multiplying
values up to 1.5.
This product cannot be used with halogen system liquid and
atmosphere.
This product cannot be used for the purpose of absorbing
vibrations from pumps.
The shipping bolts are set to adjust the face-to-face distances.
Remove them after installing the bellows.
The Fire Service Law cannot be applied.
For vacuum applications, refer to page 21.
For products with flanges made of SUS304, the standard
material for its lugs, shipping bolts, and nuts is SS400.
When using ANSI 150LB with the thick wall flange, please
consult us since its face-to-face distance is different.

Operating Pressure
TOMBO No.9062-S
Max Pressure Resistance (MPa)

No. of convolutions (3 to 10 convolutions)

1.1
1.0
0.9
0.8
0.7
0.6
0.5

50A 65A
80A 125A
150A 250A

0.4
0.3
0.2
0.1

300A 350A
400A 600A

25

50

100

150

Temperature ()

10

200

The same operating pressure is used for products with 3 to 10


convolutions.
The operating pressure table shows the values for the
standard face-to-face lengths. When using the product at the
maximum expansion and the maximum displacement, use the
values obtained by multiplying the following coefficients.
At the maximum expansion: 0.7
At the maximum displacement: 0.5
Refer to page 23 for cases where expansion or contraction and
axis displacement occur at the same time.
The maximum service temperature is 200.

Product code

Axial
Diameter Face-to-face Amount of expansion
length
and contraction displacement
nominal
mm
mm
mm
AB

Reaction
force

Dimension of expansion partsmm


Numbers of standard
convolutions

Inner diameter d Flared Diameter D

9062S 50 5
9062S 50 8
9062S 5010

50
2

100
135
160

4
6
8

2
5
9

77
48
38

5
8
10

46

95

9062S 65 5
9062S 65 8
9062S 6510

65
21/2

105
140
165

4
6
8

2
5
8

91
57
46

5
8
10

60

115

9062S 80 5
9062S 80 8
9062S 8010

80
3

110
155
185

6
9
12

2
6
10

63
40
32

5
8
10

74

125

9062S100 5
9062S100 8
9062S10010

100
4

110
155
185

6
9
12

2
5
8

77
48
40

5
8
10

98

150

9062S125 3
9062S125 5
9062S125 8
9062S12510

125
5

110
160
235
285

10
17
27
35

2
7
19
25

48
22
14
12

3
5
8
10

120

180

9062S150 3
9062S150 5
9062S150 8
9062S15010

150
6

125
185
275
335

11
19
31
39

2
8
22
35

35
16
10
8

3
5
8
10

145

210

9062S200 3
9062S200 5
9062S200 8
9062S20010

200
8

125
185
275
335

12
19
31
39.5

2
7
18
29

43
19
12
10

3
5
8
10

193

260

9062S250 3
9062S250 5
9062S250 8
9062S25010

250
10

130
190
280
340

12
19
31
39

2
6
15
24

50
23
14
11

3
5
8
10

242

320

9062S300 3
9062S300 5
9062S300 8
9062S30010

300
12

145
215
320
390

16
27
43
54

2
8
21
32

32
17
11
9

3
5
8
10

294

365

9062S350 3
9062S350 5
9062S350 8
9062S35010

350
14

150
220
325
395

16
27
43
56

2
7
19
30

36
19
12
10

3
5
8
10

327

410

9062S400 3
9062S400 5
9062S400 7

400
16

190
290
390

29
48
68

5
15
31

25
15
11

3
5
7

375

470

9062S450 3
9062S450 5
9062S450 7

450
18

195
295
395

29
48
68

5
14
28

27
17
12

3
5
7

425

525

9062S500 3
9062S500 5
9062S500 7

500
20

195
295
395

29
48
68

2
12
25

30
18
13

3
5
7

474

580

9062S550 3
9062S550 5
9062S550 7

550
22

200
300
400

29
48
68

2
11
22

32
19
14

3
5
7

524

635

9062S600 3
9062S600 5
9062S600 7

600
24

200
300
400

29
48
68

2
11
22

35
21
15

3
5
7

574

685

11

TOMBO No.9062-L
TM

NAFLON PTFE Expansion Joint (Stainless Steel Shrouding Long Type)


Standard dimensions

Construction
Parts No.

Vent-hole

Name

Standard Specifications

Bellows

PTFE

Bellows

SUS304

Flange Corresponding to JIS 10K

SS400

End Tube

SGP

Shipping Bolt

SS400

Nut

SS400

The JIS 10K flange is standard, but the ANSI 150LB type is
also available.
The holes for the flange bolts are drilled holes.
Products with a number of convolutions other than the ones in
the standard can be manufactured.
In the event of displacement caused by an earthquake, the
maximum allowable displacement is obtained by multiplying
values up to 1.5.
This product cannot be used with halogen system liquid and
atmosphere.
This product cannot be used for the purpose of absorbing
vibrations from pumps.
The shipping bolts are set to adjust the face-to-face distances.
Remove them after installing the bellows.
The Fire Service Law cannot be applied.
For vacuum applications, refer to page 21.
For products with flanges made of SUS304, the standard
material for its lugs, shipping bolts, and nuts is SS400.

Operating Pressure
TOMBO No.9062-L
Max Pressure Resistance (MPa)

No. of convolutions (3 to 10 convolutions)

1.1
1.0
0.9
0.8
0.7
0.6
0.5

50A 65A
80A 125A
150A 250A

0.4
0.3
0.2
0.1

300A 350A
400A 600A

25

50

100

150

200

The same operating pressure is used for products with 3 to 10


convolutions.
The operating pressure table shows the values for the
standard face-to-face lengths. When using the product at the
maximum expansion and the maximum displacement, use the
values obtained by multiplying the following coefficients.
At the maximum expansion: 0.7
At the maximum displacement: 0.5
Refer to page 23 for cases where expansion or contraction and
axis displacement occur at the same time.
The maximum service temperature is 200.

Diameter
nominal
AB

9062L 50 5
9062L 50 8
9062L 5010

50
2

170
205
230

4
6
8

2
5
9

77
48
38

5
8
10

46

95

9062L 65 5
9062L 65 8
9062L 6510

65
21/2

180
215
240

4
6
8

2
5
8

91
57
46

5
8
10

60

115

9062L 80 5
9062L 80 8
9062L 8010

80
3

200
245
275

6
9
12

2
6
10

63
40
32

5
8
10

74

125

9062L100 5
9062L100 8
9062L10010

100
4

200
245
275

6
9
12

2
5
8

77
48
46

5
8
10

98

150

125
5

205
255
330
380

10
17
27
35

2
7
19
25

48
22
14
12

3
5
8
10

120

180

150
6

225
285
375
435

11
19
31
39

2
8
22
35

35
16
10
8

3
5
8
10

145

210

200
8

235
295
385
445

12
19
31
39.5

2
7
18
29

43
19
12
10

3
5
8
10

193

260

250
10

245
305
395
455

12
19
31
39

2
6
15
24

50
23
14
11

3
5
8
10

242

320

300
12

280
350
455
525

16
27
43
54

2
8
21
32

32
17
11
9

3
5
8
10

294

365

350
14

280
350
455
525

16
27
43
56

2
7
19
30

36
19
12
10

3
5
8
10

327

410

9062L400 3
9062L400 5
9062L400 7

400
16

375
475
575

29
48
68

5
15
31

25
15
11

3
5
7

375

470

9062L450 3
9062L450 5
9062L450 7

450
18

385
485
585

29
48
68

5
14
28

27
17
12

3
5
7

425

525

9062L500 3
9062L500 5
9062L500 7

500
20

400
500
600

29
48
68

2
12
25

30
18
13

3
5
7

474

580

9062L550 3
9062L550 5
9062L550 7

550
22

425
525
625

29
48
68

2
11
22

32
19
14

3
5
7

524

635

9062L600 3
9062L600 5
9062L600 7

600
24

425
525
625

29
48
68

2
11
22

35
21
15

3
5
7

574

685

9062L125 3
9062L125 5
9062L125 8
9062L12510
9062L150 3
9062L150 5
9062L150 8
9062L15010
9062L200 3
9062L200 5
9062L200 8
9062L20010
9062L250 3
9062L250 5
9062L250 8
9062L25010
9062L300 3
9062L300 5
9062L300 8
9062L30010
9062L350 3
9062L350 5
9062L350 8
9062L35010

Temperature ()

12

Axial
Face-to-face Amount of expansion
and contraction displacement
length
mm
mm
mm

Product code

Reaction
force

Dimension of expansion partsmm


Numbers of standard
Inner diameter d Flared Diameter D
convolutions

13

TOMBO No.9063-S
TM

NAFLON PTFE Expansion Joint (Heat Resistance Type)


Standard dimensions

Construction
Parts No.

Name

Standard Specifications

Bellows

PTFE

Flange Corresponding to JIS 10K

SS400

Control Ring

AC7A

Limit Bolt

SS400 (Unichro-plated)

U Nut

SS400 (Unichro-plated)

The JIS 10K flange is standard, but the ANSI 150LB type is
also available.
The holes for the flange bolts are drilled holes. However, the
holes for the flange bolts with 3 convolutions of 14B or less in
size and ones with 4 convolutions of 5B or less in size are
tapped holes.
Products with a number of convolutions other than the ones in
the standard can be manufactured.
The Fire Service Law cannot be applied.
For vacuum applications, refer to page 21.
Flange thickness of ANSI150LB is same as JIS 10K Flange
standard
For products with flanges made of SUS304, the material for its
lugs, shipping bolts, and nuts is also SUS304.
The limit bolts are set with the standard face-to-face distance
(L) when shipping. Adjust them within the allowable range of
expansion and contraction, if necessary.
The limit bolt for products of nominal diameter of 200A or
more consists of a full thread bolt and nuts at both ends.
If this product is used with halogen system liquid and
atmosphere, the service life of the control ring may be
shortened depending on the conditions such as temperature,
pressure and environment. In this case, control rings made of
SUS are available.

Operating Pressure
TOMBO No.9063-S
Max Pressure Resistance (MPa)

1.0
0.9
0.8
0.7

No. of convolutions: 3

50A 200A

250A 300A

0.6
0.5
0.4
0.3

350A 400A

450A 600A

The operating pressure table shows the values for the


standard face-to-face lengths. When using the product at the
maximum expansion and the maximum displacement, use the
values obtained by multiplying the following coefficients.
At the maximum expansion: 0.7
At the maximum displacement: 0.5
Refer to page 23 for cases where expansion or contraction and
axis displacement occur at the same time.
The maximum service temperature is 200 for 3 convolutions
and 180for five convolutions.

Product code

Diameter
nominal
AB

Axial
Face-to-face Amount of expansion
and contraction displacement
length
mm
mm
mm

9063S 503
9063S 505

50
2

75
105

9063S 653
9063S 655

65
21/3

80
110

9063S 803
9063S 805

80
3

80
110

9063S1003
9063S1005

100
4

85
115

9063S1253
9063S1255

125
5

90
130

9063S1503
9063S1505

150
6

110
155

9063S2003
9063S2005

200
8

110
155

9063S2503
9063S2505

250
10

120
175

9063S3003
9063S3005

300
12

120
175

9063S3503
9063S3505

350
14

130
190

9063S4003
9063S4005

400
16

150
225

9063S5003
9063S5005

500
20

160
240

7
15
12
24
7
15
12
24
7
15
12
24
9
18
15
30
9
18
15
30
10
20
17
35
10
20
17
35
12
24
20
40
12
24
20
40
13
26
22
44
13
26
22
44
13
26
22
44

Dimension of expansion partsmm


Numbers of standard
convolutions

Inner diameter d Flared Diameter D

3
15

3
5

46

95

3
15

3
5

61

115

3
15

3
5

72

125

3
15

3
5

98

150

11
20

3
5

121

180

11
20

3
5

145

210

14
23

3
5

194

260

14
23

3
5

244

320

16
26

3
5

292

365

16
26

3
5

325

410

16
26

3
5

376

470

18
30

3
5

476

580

0.2
0.1
50

100

150

200

Temperature ()

Max Pressure Resistance (MPa)

1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1

No. of convolutions: 5

50A 125A

150A 200A

250A 300A

350A 400A

450A 600A

50

100

150

180200

Temperature ()

14

15

TOMBO No.9063-L
TM

NAFLON PTFE Expansion Joint (Heat Resistance Long Type)


Standard dimensions

Construction
Parts No.

Name

Standard Specifications

Bellows

PTFE

Flange Corresponding to JIS 10K

SS400

End Tube

Carbon steel pipe (SGP)

Collar

SS400

Control Ring

AC7A

Limit Bolt

SS400 (Unichro-plated)

U Nut

SS400 (Unichro-plated)

Hexagon Nut

SS400

The JIS 10K flange is standard, but the ANSI 150LB type is
also available.
The holes for the flange bolts are drilled holes.
Products with a number of convolutions other than the ones in
the standard can be manufactured.
The Fire Service Law cannot be applied.
Products with 6 convolutions or more are No.9063-B type.
If this product is used with halogen system liquid and
atmosphere, the service life of the control ring may be
shortened depending on the conditions such as temperature,
pressure and environment. In this case, control rings made of
SUS are available.
For products with flanges made of SUS304, the material for its
lugs, shipping bolts, and nuts is also SUS304.
The limit bolts are set with the standard face-to-face distance
(L) when shipping. Adjust them within the allowable range of
expansion and contraction, if necessary.
The limit bolt for products of nominal diameter of 200A or
more consists of a full thread bolt and nuts at both ends.

Operating Pressure
TOMBO No.9063-L
Max Pressure Resistance (MPa)

1.0

0.1

0.9
0.8
0.7

No. of convolutions: 3

50A 200A

250A 300A

0.6
0.5
0.4
0.3

350A 400A

450A 600A

The operating pressure table shows the values for the


standard face-to-face lengths. When using the product at the
maximum expansion and the maximum displacement, use the
values obtained by multiplying the following coefficients.
At the maximum expansion: 0.7
At the maximum displacement: 0.5
Refer to page 23 for cases where expansion or contraction and
axis displacement occur at the same time.
The maximum service temperature is 200 for 3 convolutions
and 180for 5 convolutions.

Product code

Diameter
nominal
AB

Face-to-face Amount of expansion


Axial
length
and contraction displacement
mm
mm
mm

9063L 503
9063L 505

50
2

190
220

9063L 653
9063L 655

65
21/2

195
225

9063L 803
9063L 805

80
3

205
235

9063L1003
9063L1005

100
4

205
240

9063L1253
9063L1255

125
5

220
260

9063L1503
9063L1505

150
6

260
305

9063L2003
9063L2005

200
8

260
305

9063L2503
9063L2505

250
10

280
335

9063L3003
9063L3005

300
12

280
335

9063L3503
9063L3505

350
14

320
380

9063L4003
9063L4005

400
16

340
415

7
15
12
24
7
15
12
24
7
15
12
24
9
18
15
30
9
18
15
30
10
20
17
35
10
20
17
35
12
24
20
40
12
24
20
40
13
26
22
44
13
26
22
44

Dimension of expansion partsmm


Numbers of standard
convolutions

Inner diameter d Flared Diameter D

3
15

3
5

46

95

3
15

3
5

61

115

3
15

3
5

72

125

3
15

3
5

98

150

11
20

3
5

121

180

11
20

3
5

145

210

14
23

3
5

194

260

14
23

3
5

244

320

16
26

3
5

292

365

16
26

3
5

325

410

16
26

3
5

376

470

0.2

50

100

150

200

Temperature ()
Max Pressure Resistance (MPa)

1.0

0.1

0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2

No. of convolutions: 5

50A 125A

150A 200A

250A 300A

350A 400A

450A 600A

50

100

150

180200

Temperature ()

16

17

TOMBO No.9064
TM

NAFLON PFA Expansion Joint


Standard dimensions

Construction
Parts No.

Name

Standard Specifications

Bellows

PFA

Flange Corresponding to JIS 10K

FCD450

Reinforcing Ring

SUS304

Limit Bolt

SS400 (Unichro-plated)

U Nut

SS400 (Unichro-plated)

Grommet

CR

Washer

SS400 (Unichro-plated)

20
3/4

9064 322
9064 323
9064 325

32
11/4

9064 402
9064 403
9064 405

40
11/2

9064 502
9064 503
9064 505

50
2

9064 652
9064 653
9064 655

65
21/2

9064 802
9064 803
9064 805

80
3

90641002
90641003
90641005

100
4

90641252
90641253
90641255

125
5

Operating Pressure

90641502
90641503
90641505

150
6

TOMBO No.9064

90642002
90642003
90642005
90642502
90642503
90642505

200
8

No. of convolutions: 2

40

80

120

160

Temperature ()

Max Pressure Resistance (MPa)

Max Pressure Resistance (MPa)

Max Pressure Resistance (MPa)

1.3
20A 100A
1.2
125A 200A
1.1
1.0
0.9
0.8 250A 300A
0.7
0.6
0.5
0.4
0.3
0.2
0.1

1.3
1.2
1.1
20A 100A
1.0
0.9
0.8
125A 200A
0.7
0.6
0.5
0.4
0.3
0.2
0.1

1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
20A 200A
0.5
0.4
0.3
0.2
0.1

No. of convolutions: 5

9064
9064
9064
9064
9064
9064

Diameter
nominal
AB

202
203
205
252
253
255

The Fire Service Law cannot be applied.


The holes for the flange bolts are tapped holes.
The sizes of the tapped holes are matched to fit the sizes of
the bolts used for JIS 10K flanges.

90643002
90643003
90643005

25
1

250
10
300
12

Face-to-face Amount of expansion


Axial
length
and contraction displacement
mm
mm
mm
6
3
35
13
44
6
13
13
65
6
35
3
13
44
6
13
65
13
6
40
3
13
49
6
13
70
13
6
40
3
13
51
6
19
75
13
6
50
3
19
68
10
25
102
13
8
57
3
19
77
10
25
115
13
10
60
5
25
85
13
25
127
13
13
64
6
25
85
13
32
127
16
13
80
6
25
100
13
32
152
16
13
80
6
32
100
14
45
152
16
13
98
6
29
133
14
45
205
18
13
120
6
29
170
14
45
205
18
13
130
6
29
190
14
51
230
18

Dimension of expansion partsmm


Numbers of standard
convolutions

2
3
5
2
3
5

Inner diameter d Flared Diameter D


24

50

24

50

2
3
5

31

62

2
3
5

37

73

2
3
5

48

92

2
3
5

61

110

2
3
5

72

120

2
3
5

96

145

2
3
5

118

175

2
3
5

143

205

194

255

236

310

285

355

2
3
5
2
3
5
2
3
5

This item will be made to order, please allow enough production Lot and lead-time. Please consult us.
250A 300A
40

80

120

160

Temperature ()

No. of convolutions: 3

The operating pressure table shows the values for the


standard face-to-face lengths. When using the product at the
maximum expansion and the maximum displacement, use the
values obtained by multiplying the following coefficients.
At the maximum expansion: 0.7
At the maximum displacement: 0.5
Refer to page 23 for cases where expansion or contraction and
axis displacement occur at the same time.
The maximum service temperature is 150.

250A 300A

40

18

Product code

80

Temperature ()

120

160

19

Special-purpose item
TOMBO No.9063-P
TM

NAFLON Bellows
Construction
Parts No.

Name
Bellows

Standard Specifications
PTFE

Flange Corresponding to JIS 10K SS400


End Tube

SGP

Collar

SS400

Control Ring

AC7A

Limit Bolt

SS400 (Unichro-plated)

Hexagon Nut

SS400 (Unichro-plated)

U Nut

SS400 (Unichro-plated)

Outer Casing and spacer SS400


Application: Prevent damage such as welding spark.

Special-purpose item
TOMBO No.9063-B
TM

NAFLON Bellows
Construction

Parts No.

Name
Bellows

Standard Specifications

Application: Large diameter and long face-to-face product.

PTFE

Please consult us for specification.

Flange Corresponding to JIS 10K SS400

20

Control Ring

AC7A

End Tube

SGP

Braid

SUS304

Backup Gasket

Non-asbestos Joint Sheet

TOMBO No.9061-SV/9062-SV/9063-SV
TM

Vacuum resistance Naflon Bellows


TOMBO No.9061SVVacuum resistance200600A
Parts No.

Name
Bellows

Standard Specifications
PTFE

Flange Corresponding to JIS 10K FCD450


Control Ring

SUS304

Limit Bolt

SS400 (Unichro-plated)

U Nut

SS400 (Unichro-plated)

Grommet

CR

Washer

SS400 (Unichro-plated)

Support Ring

PTFE

Face to face length shall be same as Tombo No. 9061


Stopper bolt is attached with Stopper and Double nut from
350A to 600A. Flange material shall be SS400.
Shrinkage allowance of certain size will be smaller than Tombo
No. 9061.
Available only to 3 Convolutions.

TOMBO No.9062SVVacuum resistance


Parts No.

Name

Standard Specifications

Bellows

PTFE

Bellows

SUS-304

Flange Corresponding to JIS 10K SS400


Limit Bolt

SS400

Nut

SS400

Support Ring

PTFE

Face to face length and expantion amount are same as TOMBO


No. 9062S.
TOMBO No. 9062-LV is installed in Sleeve inside straight point.
Available to below 5 convolutions.

TOMBO No.9063-SVVacuum resistance


Parts No.

Name
Bellows

Standard Specifications
PTFE

Flange Corresponding to JIS 10K SS400


Control Ring

AC7A

Limit Bolt

SS400 (Unichro-plated)

U Nut

SS400 (Unichro-plated)

Support Ring

PTFE

Face to face length shall be same as TOMBO No. 9063S.


Shrinkage allowance of certain size will be smaller than TOMBO
No. 9061. Please refer to Page22.
Available to below 5 convolutions.

Maximum operating temperature under vacuum condition for this item, please refer to Page22.

21

Technical Data

Vacuum resistance and maximam operating temperature


TOMBO No.

No. of convolutions

9061-HW

3 convolutions

25A150A

9061-SV

3 convolutions

200A600A

80

9062-SV

3 convolutions,
5 convolutions

50A200A

170

250A350A

100

9063-SV

3 convolutions,
5 convolutions

50A150A

150

200A350A

120

9064

Nominal diameter

2 convolutions 3 convolutions

Maximum operating temperature at 5 Torr abs


150

25150

25100

130

200250

125200

60

300

250300

25

Vacuum resistance and Maximum operating temperature under vacuum condition is not guaranteed value but test value. Please consult us before use.

Variations in the amount of contraction of the


vacuum-resistance products of the vacuum-proof products
Unitmm

TOMBO No.
No.of convolutions
Nominal diameter

22

9061-HW

9061-SV

9062-SV

9063-SV

9064

3 convolutions 3 convolutions 3 convolutions 5 convolutions 3 convolutions 5 convolutions 2 convolutions 3 convolutions

20A

13

25A

10

13

32A

13

40A

10

13

50A

15

12

19

65A

10

12

19

80A

20

12

10

25

100A

20

10

13

25

125A

15

10

17

10

13

25

150A

10

11

19

12

20

13

32

200A

26

12

19

12

20

13

29

250A

26

12

19

12

20

13

29

300A

26

16

27

12

20

13

29

350A

17

16

27

15

25

400A

20

450A

17

500A

18

550A

16

600A

16

Technical Data
Relation between the amount of expansion
and contraction and axial displacement

Expansion and contraction

Axial displacement
100
Axial displacement

The amounts of expansion and contraction and


axial displacement for each type of NAFLON
bellows listed in the standard dimensions table
are values based on the conditions that expansion
and contraction and axial displacement occur
separately.
When the two movements occur at the same
time, use the products within the range shown in
the right-hand figure.

Angular displacement

Traveling amount
of expansion
and contraction

50

Allowable amount
of expansion
and contraction

Traveling amount
of axial
displacement
Allowable amount
of axial
displacement

50100
Expansion and contraction

Reference values of pitch and the amount of


expansion and contraction per convolution
Unit: (mm)

Nominal diameter
AB

TOMBO No.9060

TOMBO No.9062

TOMBO No.9063

Pitch

Ratio of expansion and


contraction per convolution

Pitch

Ratio of expansion and


contraction per convolution

Pitch

Ratio of expansion and


contraction per convolution

203/4

3.5

0.7

251

4.0

1.0

4011/2

4.5

1.5

502

5.0

1.5

10

0.8

15

6521/2

5.5

1.5

10

0.8

16

803

6.0

2.0

15

1.2

16

1004

6.5

2.5

15

1.2

17

1255

7.0

2.5

25

3.5

19

2.5
5
2.5
5
2.5
5
3
6
3
6

1506

7.0

2.5

30

4.0

24

2008

8.0

3.3

30

4.0

24

25010

8.5

3.3

30

4.0

27

30012

9.0

3.4

35

5.4

27

35014

9.5

3.7

35

5.4

32

40016

10.5

4.5

50

9.7

38

4.5
9
4.5
9

45018

50

9.7

50020

50

9.7

41

4.5
9

55022

50

9.7

60024

50

9.7

3.5
7
3.5
7
4
8
4
8

The pitches and ratios of expansion and contraction in the above table are indicated for cases where the number of convolutions is changed to obtain a required ratio of expansion and contraction.
Please contact us for details. Please note that the number of convolutions cannot be changed for the TOMBO No.9061 and TOMBO No.9064 types as they are manufactured using metallic molding.

23

TM

Inquiry Form for Information of NAFLON Bellows


Name of your
C o m p a n y

D a t e : Month Day, Year

Your Section
Your Name

Operating conditions

Product specifications

Applicationsgeneral, food, nuclear energy,

Size

pharmaceutical, aerospace
Face-to-face distance

Others

Flange

Applicable standardspresent/absent,
High Pressure Gas Safety Law, Fire Service Law

Materialstandard, specified (

Others

StandardsJISK

ANSILB

Name of the equipment


Quantity:
Installation placeindoor, outdoor
Drawingrequired, not required
Installation purposes
Mill sheetrequired, not required

Name of the liquid, compositions of the liquid

Inspection results sheetrequired, not required


Flow velocity

Specifications sheetequired, not required

Dust, slurrypresent/absent
Temperature Maximum temperature

Normal temperature

Pressure Maximum pressure

MPa

Layout plan

MPa

Please provide a simple drawing of the layout of your equipment

Normal pressure

DisplacementExpansion and contraction

mm

mm

Axial displacement

Desired service life

years

Special instructions
Please write down any requests including special
specifications in the space provided below.

24

Drawingrequired, not required

including pumps and dampers in the space provided below.

Reference Data

Amount of pipe expansion (Excerpt from EJMA)


Amount of expansion per one-meter pipe used for the main piping at each temperature
Temperature
()

Copper pipe

Stainless steel

31/2 nickel

40
30
20
10
0
10
20
30
40
50
60
70
80
90
100
110
120
130

0.645
0.545
0.435
0.330
0.230
0.117
0.015
0.103
0.218
0.328
0.442
0.553
0.670
0.784
0.917
1.044
1.153
1.270

0.948
0.792
0.635
0.478
0.326
0.175
0.016
0.152
0.321
0.488
0.654
0.824
0.994
1.162
1.332
1.504
1.674
1.847

0.602
0.504
0.407
0.309
0.213
0.117
0.012
0.099
0.209
0.318
0.424
0.533
0.643
0.749
0.862
0.989
1.087
1.199

Unit: (mm)

Temperature
()

Copper pipe

Stainless steel

31/2 nickel

140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300

1.403
1.527
1.660
1.790
1.922
2.059
2.192
2.328
2.470
2.606
2.743
2.880
3.017
3.160
3.309
3.454
3.602

2.021
2.193
2.367
2.545
2.725
2.905
3.086
3.268
3.449
3.634
3.816
3.996
4.175
4.355
4.535
4.723
4.909

1.312
1.423
1.535
1.652
1.768
1.886
2.004
2.132
2.263
2.396
2.526
2.658
2.784
2.918
3.050
3.193
3.337

Conversion diagram showing degree of vacuum

4
3
2
1
0

0
2

100

6
200

8
10

300

12
14

10
12

14

16
400

16
18

500

20

600

24
26
28

700

29.9

760

16

700

13
12

1.1

600

ATMOSPHERIC PRESSURE
2

11
10

500

9
400

10

11

28

12

30

13

14
14.7

10

33.9

1.2

1.0

14

32

800

15

26

900

1.3

17

20
24

22

18

18
22

1000

19

300

200

12
14

16

18
20

22

2
100

24
26

1
0

=0 IN.H
=0 mmH
=0 FT.H2O
=0 PSIG
=760 mm H ABS
=14.7 PSIA
=760 TORR
=I ATMOSPHERE

28
FULL VACUM
IN. H
ATM.

mm H ABS&TORR

PSIA

PSIG
FT.H2O.

mm H

IN. H

=29.9 IN.H
=760 mm H
=33.9 FT. H2O
=14.7 PSIG
=0 mm H ABS
=0 PSIA
=0 TORR
=0 ATMOSPHERES

25

Examples of execution

26

Related Products

Piping System

Straight pipes
Tees
Equal Tees,
Reducing Tees
Elbows
90-degree elbow,
45-degree elbow
Reducers
Concentric reducers,
Eccentric reducers
Reducing flanges

Chemical injection pipes


Dip pipe, Sparger
Liquid level gauges
Medium pressure level gauge,
low pressure level gauge
Valves
Ball valves, diaphragm
valves, ball check valves
Hoses
Pressure hoses (straight),
Pliable type

Bellows
TOMBO
TOMBO
TOMBO
TOMBO

No.9061,
No.9062,
No.9063,
No.9064

Lining materials
PFA lining (FA)
Perfluoro alkoxyl alkane polymer
NAFLONTM PTFE
Polytetrafluoroethylene

27

Cautions for Handling


TM

NAFLON Bellows
Please read this instruction manual carefully to use the
products properly.
Also, make sure that this instruction manual is in the
possession of the manager responsible for maintenance and
inspection after the installation work is completed.
1.Cautions for Use
1Conditions for Use
For an expansion joint selected from TOMBO No. 9061
NAFLON PTFE, TOMBO No. 9062 NAFLON (stainless
steel lining type), and TOMBO No. 9063 NAFLON PTFE
(hereafter all these types are collectively referred to as
bellows), please ensure that the required system data such
as pressure resistance, vacuum resistance, and absorptive
capacities matches the data listed in the catalogue of
NAFLON bellows.
2Axial Misalignment
The bellows are not designed to correct an axial
misalignment of pipes. The axial misalignment of the
bellows may reduce its capacity to absorb displacement
causing stress fatigue of the product material, which will
result in a shorter service life of the product.
3Anchoring
Always anchor a pipeline at places where it changes its
direction. Mount the bellows as near as possible to these
anchoring positions. Installation without anchoring may
cause a displacement exceeding the permissible range due
to an impelling force, which will result in a damage to the
product.
4Pipe Support
Always support a pipeline with hangers and anchors to
avoid a load which may cause a displacement exceeding the
allowable range.
5Safety Measures
Bellows are used at high temperatures and high pressures
for pipelines and equipment handling hazardous substances
such as liquids and gases. Take every precaution to avoid
disasters due to leakage of the liquid. Do not mount bellows
in areas where inspection works (failure inspections
including periodical inspection) cannot be performed.
Mounting a safety cover is recommended when using
bellows under severe conditions to protect workers from
accidents in case of bellows damage.
2.Cautions for Installation
1Protection of the Ends
For expansion joints such as TOMBO No. 9061 NAFLON
PTFE, TOMBO No. 9062 NAFLON (stainless steel
shrouding type), and TOMBO No. 9063 NAFLON PTFE
(hereafter all the types are collectively referred to as
bellows), protective plates are mounted at the flared ends
before shipping. Do not remove the protective plates
other than for piping work.
Removing the protective plates on unnecessary occasions
will damage the flared ends causing a flaw or a dent and
reducing the seal performance, which may result in
leakage during operation of the piping system.
When performing piping work, always protect the flared
ends with a soft cloth and remove dirt carefully. If dirt is
caught at the flared ends, it may result in leakage during
operation of the piping system.
2Mounting Procedures
The protruding length of the mounting bolts toward the

28

rear surface of the flange shall be 3mm or less to avoid


damage to the main body of the bellows due to
interference with the bolts if the main body of the
bellows causes displacement or expansion.
Always use a gasket when tightening a flange to reduce
the contact surface pressure, and tighten bolts evenly
and by turns in a diagonal manner to ensure a good seal.
TOMBO bellows No. 9061 and No. 9063 are set to the
standard face-to-face distance with the limit bolts when
shipping. Adjust them within the maximum allowable
range of expansion and contraction according to
conditions for use in your company.
In addition, TOMBO bellows No. 9062 is mounted with
shipping bolts used for adjustment of the face-to-face
distance when performing piping work or setup work.
Always remove the shipping bolts after completing
piping work to avoid damage at the mounting sections of
the shipping bolts due to expansion and contraction of
the pipes.
After completing the mounting work of the bellows, blow
air to remove foreign materials including scrap metal
remaining at the bottoms of the convolutions of the
bellow section in order to avoid damage to the main body
of the bellows during operation of the piping system.
2Gasket
When connecting the flange surfaces of the bellows, use of
TOMBO No. 9010 NAFLON PTFE Cushion Gasket is
recommended. Combining the gasket with TOMBO No.
9400 NAFLON Paste will achieve more reliable sealing
(Selection shall be conducted after taking into consideration
the type of liquid.)
3.Cautions for Storage
Pay careful attention not to damage the products during
transportation or storage
When keeping the products for a long period of time,
keep them in a cool and dark place and avoid direct
sunlight.
Pay careful attention not to expose the products to fire
during storage
Pay careful not to apply loads to the products
4.Cautions for Inspection
1Periodical inspection
Perform the following periodical inspections two or more
times per year for early detection of abnormalities and
avoiding accidents.
Joint sections
No leakage from the joint sections
No looseness of the bolts
No corrosion at the flange sections
Main body of product
No abnormal deformations on the bellow section such as
cracks and damage
No damage to the limit bolts
No corrosion of both the control rings and the stainless
sections of TOMBO No. 9062 bellows
2When removing from piping systems
When removing the products from the piping system,
perform the removal after temperature is down to the
ordinary level.
In addition, mount the protective plates immediately after
removing the products from the piping systems to avoid
deformation and damage to the flared sections.

Cautions for handling products

1. Please use products within the permissible temperature range


specified in the catalogue.
2. Please refer to MSDS (Material safety data sheet) when using
products.
3. Please dispose of products in accordance with applicable lows for
waste disposal in each country.

WARNINGS

Please make sure you use the product in accordance with


the following rules in order to maintain its original functions
and to ensure safety in use.
1. Never allow the product to touch body tissues or body fluid.
2. When fabricating the product at above the maximum service
temperature, ventilate the room adequately so as not to inhale the
fluorinated cracked gas which will be generated.

CAUTIONS

Please note the following points in order to ensure the


original functions of the product.
1. Technical data referred to in this catalogue (to show the
performance of a product) are all actual measurement values
obtained from experiments or representative values, not
guaranteed values. Advance in-depth consideration for your
intended purpose is recommended.
2. Especially thorough consideration is required for the use of acid,
alkali, and other poisonous fluids. Please contact our technical staff
for advice.
3. Because of the nature of the materials, repetitious loads, extremely
concentrated loads, and bending loads could affect the durability of
the product. Always check the condition of the product before use.
4. Fluoropolymer is self-lubricating by nature, but it does become
worn after some time. Periodical replacement is recommended for
the parts in which a lot of wear is observed.
5. Depending on the usage environment, fluid could penetrate the
fluoropolymer. Hardening and change in size could also occur, so
always check the condition of the product before use.
6. We can offer products with specifications other than the ones given
in the catalogue. However, please note that these may require
additional costs and lead time.
7. Please contact either our salesperson or technical staff for any
further advice you may need.

29