AC centrifugal fans
Technical information
Product line
Bearings
motors.
addition to complete device fans, you will also find fans without external
available.
The line of AC fans for Euro voltage according to IEC 60038 (230 V 10 %)
AC fans are available in a variety of sizes with either air exhaust or air
intake over struts. Silent running models with sleeve bearings (or for
extreme ambient conditions) fans with ball bearings are available.
Frequencies
Capacitor
the world-famous ebm-papst external rotor principle: The fan blades are
directly attached to the external rotor of the external rotor motor, thus
Overloading
ebm-papst also has particularly flat built AC fans with internal rotor motor.
Almost all AC fans are protected against overloading (e.g. due to locked
Their advantage: quick start to full speed. A plastic impeller and the both
smaller and lighter internal rotor motor lead to a lower moment of inertia.
2014-11
228
Information
DC axial fans
Page
Air flow
10
m3/h
mm
20
30
40
50
60
70 80 90 100
200
300
400
2000
3000
c 121 x 37
RL 90
40...42
230
135 x 38
RG 90
47...54
231
180 x 40
RG 125
86...94
232
220 x 56
RG 160
202...223
233
138 x 40
RER 125
104...115
234
176 x 54
RER 160
234...274
235
DC centrifugal fans
Series
Dimension
DC fans - specials
Subject to alternations
ACmaxx / GreenTech
EC-Compact fans
Spee
d sig
nal
Hum
idity
prote
ction
IP >
= IP
54
IP >
= IP
68
Salt
fog p
rotec
tion
Page
Centrifugal fans
mm
RL 90
121 x 121 x 37
RG 90
RG 125
OPTIONAL
ja
135 x 135 x 38
ja
180 x 180 x 40
ja
RG 160
220 x 220 x 56
ja
RER 125
138 x 40
ja
RER 160
176 x 54
ja
p.
230
231
232
233
AC axial fans
Series
234
235
Subject to alternations
Ball bearings
AC centrifugal fans
Sleeve bearings
Accessories
229
2014-11
availabe
Representatives
Sinte
c
ball sleeve b
bear earing
ings
s/
CSA
VDE
, UL,
Dim
ensio
n
max.
42 m /h
AC centrifugal fans
Material:
Nominal voltage
Frequency
Input power
Nominal speed
Temperature range
CFM
VAC
Hz
Bel(A)
Watts
rpm
Hours
RL 90-18/50
40
23,5
230
50
5,6
20,0
2 450
-10...+50
37 500 / 30 000
RL 90-18/56
40
23,5
230
50
5,6
20,0
2 450
-30...+70
37 500 / 20 000
RL 90-18/00
42
24,7
115
60
6,0
19,5
2 550
-10...+60
37 500 / 25 000
RL 90-18/06
42
24,7
115
60
6,0
19,5
2 550
-30...+85
37 500 / 15 000
Type
Subject to alternations
Pa
[in H2O]
Fan type
RL 90-18/00
AWG 18, TR 32
RL 90-18/56
RL 90-18/06
AWG 22
0,4
120
100
0,3
80
0,2
60
0,1
40
20
tin-plated
10
12
15
20
16
25
20
30
2014-11
50 Hz
230
CFM
m/h
60 Hz
Lead wires
RL 90-18/50
Curve
Air flow
m3/h
Nominal data
at T m ax
Air flow
1) Fibreglass-reinforced plastic
Hours
54 m /h
Information
max.
AC centrifugal fans
DC axial fans
DC centrifugal fans
Material:
Frequency
Input power
Nominal speed
Temperature range
VAC
Hz
Bel(A)
Watts
rpm
Hours
RG 90-18/50
54
32
230
50
5,8
22,0
2 200
-30...+60
35 000 / 22 500
RG 90-18/56
54
32
230
50
5,8
22,0
2 200
-30...+60
35 000 / 22 500
RG 90-18/00
47
28
115
60
6,2
22,0
1 900
-30...+65
35 000 / 20 000
RG 90-18/06
47
28
115
60
6,2
22,0
1 900
-30...+65
35 000 / 20 000
DC fans - specials
Nominal voltage
CFM
Hours
ACmaxx / GreenTech
EC-Compact fans
Type
Curve
Air flow
m3/h
Nominal data
at T m ax
Air flow
1) Fibreglass-reinforced plastic
100
0,4
120
AC centrifugal fans
Pa
[in H2O]
AC axial fans
Subject to alternations
0,3
Accessories
80
0,2
60
40
10
10
15
20
20
30
25
40
50 Hz
Guard grilles
from p. 238
30
50
CFM
m/h
60 Hz
231
2014-11
Representatives
tin-pla
ted
0,1
20
94 m /h
AC centrifugal fans
max.
Material:
Nominal voltage
Frequency
Input power
Nominal speed
Temperature range
CFM
VAC
Hz
Bel(A)
Watts
rpm
Hours
RG 125-19/56
86
51
230
50
5,8
20,0
2 550
-30...+70
37 500 / 20 000
RG 125-19/06
94
55
115
60
6,0
19,0
2 750
-30...+80
40 000 / 15 000
Type
Pa
[in H2O]
Subject to alternations
200
0,4
0,6
100
50
0,2
150
tin-pla
ted
0
10
20
20
30
40
40
2014-11
50 Hz
232
Guard grilles
from p. 238
50
80
60
CFM
m/h
60 Hz
Curve
Air flow
m3/h
Nominal data
at T m ax
Air flow
1) Fibreglass-reinforced plastic
Hours
223 m /h
Information
max.
AC centrifugal fans
DC axial fans
DC centrifugal fans
Material:
Nominal voltage
Frequency
Input power
Nominal speed
Temperature range
m3/h
CFM
VAC
Hz
Bel(A)
Watts
rpm
Hours
RG 160-28/56S
202
119
230
50
6,6
47,0
2 750
-30...+70
30 000 / 15 000
RG 160-28/06S
223
131
115
60
6,9
50,0
3 050
-30...+80
27 500 / 12 500
DC fans - specials
Curve
Air flow
Type
Nominal data
at T m ax
Air flow
1) Fibreglass-reinforced plastic
Hours
AC centrifugal fans
[in H2O]
Pa
AC axial fans
ACmaxx / GreenTech
EC-Compact fans
Subject to alternations
tin-pla
ted
20
40
50
60
100
80
100
120
200
150
50 Hz
Guard grilles
from p. 238
CFM
m/h
60 Hz
233
Representatives
100
2014-11
0,8
1,2
200
0,4
300
Accessories
400
115 m /h
AC centrifugal fans
max.
Material:
Nominal voltage
Frequency
Input power
Nominal speed
Temperature range
m3/h
CFM
VAC
Hz
Bel(A)
Watts
rpm
Hours
RER 125-19/56
104
61
230
50
6,2
19,0
2 600
-30...+60
37 500 / 22 500
RER 125-19/06
115
68
115
60
6,5
18,0
2 850
-30...+70
40 000 / 20 000
Curve
Air flow
Type
Nominal data
at T m ax
Air flow
1) Fibreglass-reinforced plastic
Hours
Subject to alternations
Pa
[in H2O]
100
80
0,3
0,2
60
0,1
40
20
10
20
20
30
40
40
60
50
80
60
CFM
100
m/h
2014-11
50 Hz
234
Guard grilles
from p. 238
Inlet nozzles
from p. 248
60 Hz
tin-plated
Information
274 m /h
AC centrifugal fans
max.
DC axial fans
DC centrifugal fans
Material:
Nominal voltage
Frequency
Input power
Nominal speed
Temperature range
m3/h
CFM
VAC
Hz
Bel(A)
Watts
rpm
Hours
RER 160-28/56S
234
138
230
50
6,6
45,0
2 800
-30...+60
30 000 / 20 000
RER 160-28/06S
274
161
115
60
6,8
46,0
3 250
-30...+70
30 000 / 15 000
DC fans - specials
Curve
Air flow
Type
Nominal data
at T m ax
Air flow
1) Fibreglass-reinforced plastic
Hours
ACmaxx / GreenTech
EC-Compact fans
Subject to alternations
AC axial fans
AC centrifugal fans
Pa
[in H2O]
tin-plated
250
Accessories
0
30
60
50
100
90
150
120
200
50 Hz
Guard grilles
from p. 238
150
250
CFM
m/h
60 Hz
Inlet nozzles
from p. 248
235
Representatives
50
2014-11
0,4
0,6
100
0,2
150
0,8
200
2014-11
236