Professional Documents
Culture Documents
Typical Applications
Mixed metal oxide anodes have proven to
operate effectively in all types of environments,
including areas with extremely low pH levels
(under 1), and high chloride concentrations.
While Corrpro tubular anodes can be used
singularly, their unique configuration also makes
them ideal for use in strings on offshore
platforms or in deep groundbeds. In addition,
the string anodes can be installed parallel to
transmission pipelines, or used for other special
applications.
CHEMICAL COMPOSITION
Substrate
ASTM B-338
Grade 1 Titanium
Catalyst
Mixed
Metal Oxide
Corrpro Companies Europe Limited
Adam Street, Bowesfield Lane, Stockton on Tees, TS18 3HQ
Telephone: (01642) 614106 (8 lines) Telex: 587388
Fax: (01642) 614100 E-mail: ccel@corrpro.co.uk
Tubular Anodes
Ordering Procedure
Corrpro tubular mixed metal oxide anodes are
available in several different dimensions. To
order the required anode for your structure,
indicate that you need a tubular mixed metal
oxide anode, and specify the quantity desired,
the anode type, the lead wire length, size, and
insulation, and whether it should be packaged or
bare. An example is provided to help illustrate
this process.
EXAMPLE
Quantity
Anode
Material
Anode Type
Wire:
Length
Size
(#6 or #1/0 = Standard
Insulation
(EPR/CSPE = Standard)
Packaging
(Bare or Packaged)
200
Tubular Mixed
Metal Oxide
M754
20 ft.
#6 AWG
EPR/CSPE
Packaged
LENGTH
NOMINAL WEIGHT
BARE
PKGD.
ANODE
TYPE
in.
(mm)
in.
(mm)
oz./ft.
(g/m)
lbs.
(kg)
CURRENT
RATING*
amps
M752
M754
M103
M124
0.75
0.75
1.0
1.25
(19.1)
(19.1)
(25.4)
(31.8)
2.0
4.0
3.3
4.0
(610)
(1,219)
(1,006)
(1,219)
3.4
3.4
3.8
5.8
(314)
(314)
(351)
(538)
23
25
25
27
(10.5)
(11.4)
(11.4)
(12.3)
2.6
5.1
11.1