You are on page 1of 137

POLYESTER ENCLOSURES

Presentation

3/2

Selection guide

3/4

SYSTEM 27
Insulating modular boxes

3/14

POLYMEL PLM
Monobloc polyester enclosures

3/38

PLA
Polyester enclosures

3/68

PLD
Polyester enclosures and plinths

03_000_001_EN.ndd 3

3/118

2/4/08 12:38:53

Fibreglass-reinforced polyester
enclosures

PLM enclosure installed


inside or outside in
harsh environments:
petrochemical, cement
plants, paper plants, iron
and steel producers, etc.

PLA enclosures resistant


to corrosive chemical and
atmospheric agents.

PLD enclosure with


incorporated ZD plinth,
electrical distribution
application.

Enclosure
features

WALL MOUNTING
S ystem 27

PO LY MEL

Degree of protection

IP65/IK09

IP66/IK10

No. of sizes/models

14/35

8/26

from

180 270 180

310 215 160

up to

540 720 230

1056 852 350

Metal

Insulating

Dimensions (mm)

Installation
systems

Mounting plates

Distribution Chassis
18 mm modules

up to 48

Accessories

up to 240

Internal doors

Page

Universal

Canopies
Plinths

3/14

3/38

3/2

03_002_013_EN.indd 2

2/4/08 12:40:28

c Insulating modular boxes system 27:


composed of the base, with high and low cover variations, transparent and
opaque, made of polycarbonate or polyester.
c POLYMEL polyester enclosures:
monobloc construction, one single piece highly resistant body, with
possible enclosure coupling.
c PLA polyester enclosures and plinths:
4 construction systems:
fully closed enclosures,
enclosures with self-ventilated top with canopy and closed bottom,
enclosures with closed top and open plinth-type bottom,
enclosures with self-ventilated top with canopy and open
plinth-type bottom.
Enclosures with front door, and enclosures with front door and back door.
3 versions of doors: plain, transparent or ribbed.
c PLD-ZD polyester enclosures and plinths:
prepared to directly incorporate the fuse holder plinths for electrical
distribution.

FLOOR STANDING
PL A

PLD-ZD

IP65/54/IK10

IP43/54/IK10

40/960

5/5

500 500 320

850 465 320

1500 1250 420

850 1115 320

up to 364

3/68

3/118

3/3

03_002_013_EN.indd 3

2/4/08 12:40:32

Hot-press moulded
polyester enclosures

Selection guide

System 27
TABLE OF MODELS, DIMENSIONS AND REFERENCES
Transparent cover boxes

Opaque cover boxes

Polyester box cover

Bases

Transparent covers

Box dimensions (mm)

Depth

High cover ref.

Low cover ref.

High cover ref.

270

180

PLS 1827

PLSO 1827

PLSP 1827

FPLS 1827 N

TPLS 1827

270

180

PLS 2727

PLSO 2727

PLSP 2727

FPLS 2727 N

TPLS 2727

270

270

230

PLS 2727 A

FPLS 2727 N

TPLS 2727 A

270

360

180

PLS 2736

PLSP 2736

FPLS 2736 N

TPLS 2736

270

360

230

PLS 2736 A

FPLS 2736 N

TPLS 2736 A

270

540

180

PLS 2754

PLSP 2754

FPLS 2754 N

TPLS 2754

270

540

230

PLS 2754 A

FPLS 2754 N

TPLS 2754 A

360

360

180

PLS 3636

PLSO 3636

PLSP 3636

FPLS 3636 N

TPLS 3636

360

540

180

PLS 3654

PLSO 3654

PLSP 3654

FPLS 3654 N

TPLS 3654

360

540

230

PLS 3654 A

FPLS 3654 N

TPLS 3654 A

540

540

180

PLS 5454

PLSO 5454

PLSP 5454

FPLS 5454 N

TPLS 5454

540

540

230

PLS 5454 A

PLSO 5454 A

FPLS 5454 N

TPLS 5454 A

360

720

230

PLS 3672 A

PLSO 3672 A

FPLS 3672 N

TPLS 3672 A

540

720

230

PLS 5472 A

PLSO 5472 A

FPLS 5472 N

TPLS 5472 A

3/17

3/17

3/17

3/17

3/17

Height

Width

180
270

Page

High cover ref.

Low cover ref.

PLSO 2727A

PLSO 2736
-

PLSO 2736 A

PLSO 2754
-

PLSO 2754 A

PLSO 3654 A
-

3/17

3/17

3/17

Low cover ref.


-

Polymel
TABLE OF MODELS, DIMENSIONS AND REFERENCES
Enclosures with plain
doors

Enclosures with transparent


doors

Adjustable
plate support

Mounting plates

Enclosure dimensions (mm)

Lock

Lock
Insulating

Height

Width

Depth

Plain

Three-point

Plain

Three-point

Metal
Bakelite

Polyester

Microperforated

Universal
perforated

310

215

160

PLM-32

PLM-32/KT

MB-32

MP-32

MM-32

MF-32

MR-32

308

255

160

PLM-3025

PLM-3025/KT

MB-3025

MP-3025

MM-3025

MF-3025

MR-3025

430

330

200

PLM-43

PLM-43/CME

PLM-43/KT

PLM-43 KT/CME

MB-43

MP-43

MM-43

MF-43

MR-43

530

430

200

PLM-54

PLM-54/CME

PLM-54/KT

PLM-54 KT/CME

MB-54

MP-54

MM-54

MF-54

MR-54

DPLM-200

647

436

250

PLM-64

PLM-64/CME

PLM-64/KT

PLM-64 KT/CME

MB-64

MP-64

MM-64

MF-64

MR-64

DPLM-250

747

536

300

PLM-75

PLM-75/CME

PLM-75/KT

PLM-75 KT/CME

MB-75

MP-75

MM-75

MF-75

MR-75

DPLM-300N

847

636

300

PLM-86

PLM-86/CME

PLM-86/KT

PLM-86 KT/CME

MB-86

MP-86

MM-86

MF-86

MR-86

DPLM-300N

1000

800

350

PLM-108

PLM-108/KT

MB-108

MP-108

MM-108

MF-108

MR-108

DPLM-350

3/41

3/41

Page

3/41

3/41

3/48

3/48

3/48

3/48

3/48

DPLM-200

3/49

3/4

03_002_013_EN.indd 4

2/4/08 12:40:33

Opaque covers

Low cover ref.

Polyester covers

High cover ref.

Mounting plates

Steel

Polyester

Boxes with DINMEL modular chassis

Bakelite

No. of modules
18 mm

No. of rows

DINMEL chassis

Reference

TPLSO 1827

TPLSP 1827

PMM 1827

PMA 1827

PMA/B 1827

12

S27 DL/12

TPLSO 2727

TPLSP 2727

PMM 2727

PMA 2727

PMA/B 2727

24

S27 DL24

PMM 2727

PMA 2727

PMA/B 2727

PMM 2736

PMA 2736

PMA/B 2736

24

PMM 2736

PMA 2736

PMA/B 2736

PMM 2754

PMA 2754

PMA/B 2754

48

PMM 2754

PMA 2754

PMA/B 2754

TPLSO 2727 A

TPLSO 2736
-

TPLSP 2736

TPLSO 2736 A

TPLSO 2754
-

TPLSP 2754

TPLSO 2754 A

DL 27/12
DL 27/24

DL 27/24

S27 DL/24-2
S27 DL/36

DL 27/24-2
DL 27/36
DL 27/24-2
DL 27/36

S27 DL748

DL 27/48
DL 27/48

TPLSO 3636

TPLSP 3636

PMM 3636

PMA 3636

PMA/B 3636

TPLSO 3654

TPLSP 3654

PMM 3654

PMA 3654

PMA/B 3654

PMM 3654

PMA 3654

PMA/B 3654

PMM 5454

PMA 5454

PMA/B 5454

TPLSO 3654 A

TPLSO 5454

TPLSP 5454

TPLSO 5454 A

PMM 5454

PMA 5454

PMA/B 5454

TPLSO 3672 A

PMM 3672

PMA 3672

PMA/B 3672

TPLSO 5472 A

PMM 5472

PMA 5472

PMA/B 5472

3/17

3/17

3/17

3/17

3/17

3/17

DINIMEL chassis

Internal door set

3/35

Post fixing set

3/17

Floor-mounting pillar

Automatic rail
Reference
DL/PLM18

No. of rows

Quantity

No. of modules
18 mm

No. of plates

18

PI-3025/PLM

DLA-24

24

PIP-43

SFP-300

DLA-48

48

PIP-54

SFP-400

SFS/PLM

DLA-48P

48

66

88

DLA-66
DLA-84

84

DLA112

112

DLA-240

234

3/63

PIP-64

SFP-400

SFS/PLM

PIP-75

SFP-500

PIP-86

SFP-600

PIP-108

3/45

3/45

3/43

3/5

03_002_013_EN.indd 5

2/4/08 12:40:41

Hot-press moulded
polyester enclosures

Selection guide

PLA
TABLE OF MODELS, DIMENSIONS AND REFERENCES
PLA enclosures with rear panel
Door

Completely closed
Plain

Ribbed

Self-ventilated top with canopy


Transparent

Plain

Ribbed

Lock

Flat

Handle

Door opening

120

120

Degree of protection

IP65

IP54

Transparent

Nominal dimensions (mm)


Height

Width

Depth

No. of
doors

500

500

320

PLA 553

PLA 553 R

PLA 553 KT

PLA 553 T

PLA 553 TR

PLA 553 TKT

420

PLA 554

PLA 554 R

PLA 554 KT

PLA 554 T

PLA 554 TR

PLA 554 TKT

320

PLA 573

PLA 573 R

PLA 573 KT

PLA 573 T

PLA 573 TR

PLA 573 TKT

420

PLA 574

PLA 574 R

PLA 574 KT

PLA 574 T

PLA 574 TR

PLA 574 TKT

750
1000

320

PLA 5103

PLA 5103 R

PLA 5103 KT

PLA 5103 T

PLA 5103 TR

PLA 5103 TKT

420

PLA 5104

PLA 5104 R

PLA 5104 KT

PLA 5104 T

PLA 5104 TR

PLA 5104 TKT

320

PLA 5123

PLA 5123 R

PLA 5123 KT

PLA 5123 T

PLA 5123 TR

PLA 5123 TKT

420

PLA 5124

PLA 5124 R

PLA 5124 KT

PLA 5124 T

PLA 5124 TR

PLA 5124 TKT

320

PLA 753

PLA 753 R

PLA 753 KT

PLA 753 T

PLA 753 TR

PLA 753 TKT

420

PLA 754

PLA 754 R

PLA 754 KT

PLA 754 T

PLA 754 TR

PLA 754 TKT

320

PLA 773

PLA 773 R

PLA 773 KT

PLA 773 T

PLA 773 TR

PLA 773 TKT

420

PLA 774

PLA 774 R

PLA 774 KT

PLA 774 T

PLA 774 TR

PLA 774 TKT

1000

320

PLA 7103

PLA 7103 R

PLA 7103 KT

PLA 7103 T

PLA 7103 TR

PLA 7103 TKT

420

PLA 7104

PLA 7104 R

PLA 7104 KT

PLA 7104 T

PLA 7104 TR

PLA 7104 TKT

1250

320

PLA 7123

PLA 7123 R

PLA 7123 KT

PLA 7123 T

PLA 7123 TR

PLA 7123 TKT

420

PLA 7124

PLA 7124 R

PLA 7124 KT

PLA 7124 T

PLA 7124 TR

PLA 7124 TKT

320

PLA 1053

PLA 1053 R

PLA 1053 KT

PLA 1053 T

PLA 1053 TR

PLA 1053 TKT

420

PLA 1054

PLA 1054 R

PLA 1054 KT

PLA 1054 T

PLA 1054 TR

PLA 1054 TKT

320

PLA 1073

PLA 1073 R

PLA 1073 KT

PLA 1073 T

PLA 1073 TR

PLA 1073 TKT

420

PLA 1074

PLA 1074 R

PLA 1074 KT

PLA 1074 T

PLA 1074 TR

PLA 1074 TKT

320

PLA 10103

PLA 10103 R

PLA 10103 KT

PLA 10103 T

PLA 10103 TR

PLA 10103 TKT

420

PLA 10104

PLA 10104 R

PLA 10104 KT

PLA 10104 T

PLA 10104 TR

PLA 10104 TKT

320

PLA 10123

PLA 10123 R

PLA 10123 KT

PLA 10123 T

PLA 10123 TR

PLA 10123 TKT

420

PLA 10124

PLA 10124 R

PLA 10124 KT

PLA 10124 T

PLA 10124 TR

PLA 10124 TKT

320

PLA 1253

PLA 1253 R

PLA 1253 KT

PLA 1253 T

PLA 1253 TR

PLA 1253 TKT

420

PLA 1254

PLA 1254 R

PLA 1254 KT

PLA 1254 T

PLA 1254 TR

PLA 1254 TKT

320

PLA 1273

PLA 1273 R

PLA 1273 KT

PLA 1273 T

PLA 1273 TR

PLA 1273 TKT

420

PLA 1274

PLA 1274 R

PLA 1274 KT

PLA 1274 T

PLA 1274 TR

PLA 1274 TKT

320

PLA 12103

PLA 12103 R

PLA 12103 KT

PLA 12103 T

PLA 12103 TR

PLA 12103 TKT

420

PLA 12104

PLA 12104 R

PLA 12104 KT

PLA 12104 T

PLA 12104 TR

PLA 12104 TKT

320

PLA 12123

PLA 12123 R

PLA 12123 KT

PLA 12123 T

PLA 12123 TR

PLA 12123 TKT

420

PLA 12124

PLA 12124 R

PLA 12124 KT

PLA 12124 T

PLA 12124 TR

PLA 12124 TKT

320

PLA 1553

PLA 1553 R

PLA 1553 KT

PLA 1553 T

PLA 1553 TR

PLA 1553 TKT

420

PLA 1554

PLA 1554 R

PLA 1554 KT

PLA 1554 T

PLA 1554 TR

PLA 1554 TKT

320

PLA 1573

PLA 1573 R

PLA 1573 KT

PLA 1573 T

PLA 1573 TR

PLA 1573 TKT

420

PLA 1574

PLA 1574 R

PLA 1574 KT

PLA 1574 T

PLA 1574 TR

PLA 1574 TKT

320

PLA 15103

PLA 15103 R

PLA 15103 KT

PLA 15103 T

PLA 15103 TR

PLA 15103 TKT

420

PLA 15104

PLA 15104 R

PLA 15104 KT

PLA 15104 T

PLA 15104 TR

PLA 15104 TKT

320

PLA 15123

PLA 15123 R

PLA 15123 KT

PLA 15123 T

PLA 15123 TR

PLA 15123 TKT

420

PLA 15124

PLA 15124 R

PLA 15124 KT

PLA 15124 T

PLA 15124 TR

PLA 15124 TKT

3/73

3/73

3/73

1250
750

500
750

1000

500
750
1000
1250

1250

500
750
1000
1250

1500

500
750
1000
1250

Page

3/75

3/75

3/75

3/6

03_002_013_EN.indd 6

2/4/08 12:40:43

Open plinth-type base


Plain

Ribbed

Self-ventilating top with canopy and open plinth-type base


Transparent

Plain

Ribbed

Handle

Handle

120

180

IP54

IP54

Transparent

PLAZ 553

PLAZ 553 R

PLAZ 553 KT

PLAZ 553 T

PLAZ 553 TR

PLAZ 553 TKT

PLAZ 554

PLAZ 554 R

PLAZ 554 KT

PLAZ 554 T

PLAZ 554 TR

PLAZ 554 TKT

PLAZ 573

PLAZ 573 R

PLAZ 573 KT

PLAZ 573 T

PLAZ 573 TR

PLAZ 573 TKT

PLAZ 574

PLAZ 574 R

PLAZ 574 KT

PLAZ 574 T

PLAZ 574 TR

PLAZ 574 TKT

PLAZ 5103

PLAZ 5103 R

PLAZ 5103 KT

PLAZ 5103 T

PLAZ 5103 TR

PLAZ 5103 TKT

PLAZ 5104

PLAZ 5104 R

PLAZ 5104 KT

PLAZ 5104 T

PLAZ 5104 TR

PLAZ 5104 TKT

PLAZ 5123

PLAZ 5123 R

PLAZ 5123 KT

PLAZ 5123 T

PLAZ 5123 TR

PLAZ 5123 TKT

PLAZ 5124

PLAZ 5124 R

PLAZ 5124 KT

PLAZ 5124 T

PLAZ 5124 TR

PLAZ 5124 TKT

PLAZ 753

PLAZ 753 R

PLAZ 753 KT

PLAZ 753 T

PLAZ 753 TR

PLAZ 753 TKT

PLAZ 754

PLAZ 754 R

PLAZ 754 KT

PLAZ 754 T

PLAZ 754 TR

PLAZ 754 TKT

PLAZ 773

PLAZ 773 R

PLAZ 773 KT

PLAZ 773 T

PLAZ 773 TR

PLAZ 773 TKT

PLAZ 774

PLAZ 774 R

PLAZ 774 KT

PLAZ 774 T

PLAZ 774 TR

PLAZ 774 TKT

PLAZ 7103

PLAZ 7103 R

PLAZ 7103 KT

PLAZ 7103 T

PLAZ 7103 TR

PLAZ 7103 TKT

PLAZ 7104

PLAZ 7104 R

PLAZ 7104 KT

PLAZ 7104 T

PLAZ 7104 TR

PLAZ 7104 TKT

PLAZ 7123

PLAZ 7123 R

PLAZ 7123 KT

PLAZ 7123 T

PLAZ 7123 TR

PLAZ 7123 TKT

PLAZ 7124

PLAZ 7124 R

PLAZ 7124 KT

PLAZ 7124 T

PLAZ 7124 TR

PLAZ 7124 TKT

PLAZ 1053

PLAZ 1053 R

PLAZ 1053 KT

PLAZ 1053 T

PLAZ 1053 TR

PLAZ 1053 TKT

PLAZ 1054

PLAZ 1054 R

PLAZ 1054 KT

PLAZ 1054 T

PLAZ 1054 TR

PLAZ 1054 TKT

PLAZ 1073

PLAZ 1073 R

PLAZ 1073 KT

PLAZ 1073 T

PLAZ 1073 TR

PLAZ 1073 TKT

PLAZ 1074

PLAZ 1074 R

PLAZ 1074 KT

PLAZ 1074 T

PLAZ 1074 TR

PLAZ 1074 TKT

PLAZ 10103

PLAZ 10103 R

PLAZ 10103 KT

PLAZ 10103 T

PLAZ 10103 TR

PLAZ 10103 TKT

PLAZ 10104

PLAZ 10104 R

PLAZ 10104 KT

PLAZ 10104 T

PLAZ 10104 TR

PLAZ 10104 TKT

PLAZ 10123

PLAZ 10123 R

PLAZ 10123 KT

PLAZ 10123 T

PLAZ 10123 TR

PLAZ 10123 TKT

PLAZ 10124

PLAZ 10124 R

PLAZ 10124 KT

PLAZ 10124 T

PLAZ 10124 TR

PLAZ 10124 TKT

PLAZ 1253

PLAZ 1253 R

PLAZ 1253 KT

PLAZ 1253 T

PLAZ 1253 TR

PLAZ 1253 TKT

PLAZ 1254

PLAZ 1254 R

PLAZ 1254 KT

PLAZ 1254 T

PLAZ 1254 TR

PLAZ 1254 TKT

PLAZ 1273

PLAZ 1273 R

PLAZ 1273 KT

PLAZ 1273 T

PLAZ 1273 TR

PLAZ 1273 TKT

PLAZ 1274

PLAZ 1274 R

PLAZ 1274 KT

PLAZ 1274 T

PLAZ 1274 TR

PLAZ 1274 TKT

PLAZ 12103

PLAZ 12103 R

PLAZ 12103 KT

PLAZ 12103 T

PLAZ 12103 TR

PLAZ 12103 TKT

PLAZ 12104

PLAZ 12104 R

PLAZ 12104 KT

PLAZ 12104 T

PLAZ 12104 TR

PLAZ 12104 TKT

PLAZ 12123

PLAZ 12123 R

PLAZ 12123 KT

PLAZ 12123 T

PLAZ 12123 TR

PLAZ 12123 TKT

PLAZ 12124

PLAZ 12124 R

PLAZ 12124 KT

PLAZ 12124 T

PLAZ 12124 TR

PLAZ 12124 TKT

PLAZ 1553

PLAZ 1553 R

PLAZ 1553 KT

PLAZ 1553 T

PLAZ 1553 TR

PLAZ 1553 TKT

PLAZ 1554

PLAZ 1554 R

PLAZ 1554 KT

PLAZ 1554 T

PLAZ 1554 TR

PLAZ 1554 TKT

PLAZ 1573

PLAZ 1573 R

PLAZ 1573 KT

PLAZ 1573 T

PLAZ 1573 TR

PLAZ 1573 TKT

PLAZ 1574

PLAZ 1574 R

PLAZ 1574 KT

PLAZ 1574 T

PLAZ 1574 TR

PLAZ 1574 TKT

PLAZ 15103

PLAZ 15103 R

PLAZ 15103 KT

PLAZ 15103 T

PLAZ 15103 TR

PLAZ 15103 TKT

PLAZ 15104

PLAZ 15104 R

PLAZ 15104 KT

PLAZ 15104 T

PLAZ 15104 TR

PLAZ 15104 TKT

PLAZ 15123

PLAZ 15123 R

PLAZ 15123 KT

PLAZ 15123 T

PLAZ 15123 TR

PLAZ 15123 TKT

PLAZ 15124

PLAZ 15124 R

PLAZ 15124 KT

PLAZ 15124 T

PLAZ 15124 TR

PLAZ 15124 TKT

3/77

3/77

3/77

3/79

3/79

3/79

3/7

03_002_013_EN.indd 7

2/4/08 12:40:44

Hot-press moulded
polyester enclosures

Selection guide

PLA
TABLE OF MODELS, DIMENSIONS AND REFERENCES
PLA enclosures with rear door
Door

Self-ventilated top with canopy

Completely closed
Plain

Ribbed

Transparent

Plain

Ribbed

Lock

Flat

Handle

Door opening

120

120

Degree of protection

IP65

IP54

Transparent

Nominal dimensions (mm)


Height

Width

Depth

No. of
doors

500

500

320

PLA 553 P

PLA 553 PR

PLA 553 PKT

PLA 553 TP

PLA 553 TPR

PLA 553 TPKT

420

PLA 554 P

PLA 554 PR

PLA 554 PKT

PLA 554 TP

PLA 554 TPR

PLA 554 TPKT

320

PLA 573 P

PLA 573 PR

PLA 573 PKT

PLA 573 TP

PLA 573 TPR

PLA 573 TPKT

420

PLA 574 P

PLA 574 PR

PLA 574 PKT

PLA 574 TP

PLA 574 TPR

PLA 574 TPKT

320

PLA 5103 P

PLA 5103 PR

PLA 5103 PKT

PLA 5103 TP

PLA 5103 TPR

PLA 5103 TPKT

420

PLA 5104 P

PLA 5104 PR

PLA 5104 PKT

PLA 5104 TP

PLA 5104 TPR

PLA 5104 TPKT

320

PLA 5123 P

PLA 5123 PR

PLA 5123 PKT

PLA 5123 TP

PLA 5123 TPR

PLA 5123 TPKT

420

PLA 5124 P

PLA 5124 PR

PLA 5124 PKT

PLA 5124 TP

PLA 5124 TPR

PLA 5124 TPKT

320

PLA 753 P

PLA 753 PR

PLA 753 PKT

PLA 753 TP

PLA 753 TPR

PLA 753 TPKT

420

PLA 754 P

PLA 754 PR

PLA 754 PKT

PLA 754 TP

PLA 754 TPR

PLA 754 TPKT

320

PLA 773 P

PLA 773 PR

PLA 773 PKT

PLA 773 TP

PLA 773 TPR

PLA 773 TPKT

420

PLA 774 P

PLA 774 PR

PLA 774 PKT

PLA 774 TP

PLA 774 TPR

PLA 774 TPKT

320

PLA 7103 P

PLA 7103 PR

PLA 7103 PKT

PLA 7103 TP

PLA 7103 TPR

PLA 7103 TPKT

420

PLA 7104 P

PLA 7104 PR

PLA 7104 PKT

PLA 7104 TP

PLA 7104 TPR

PLA 7104 TPKT

320

PLA 7123 P

PLA 7123 PR

PLA 7123 PKT

PLA 7123 TP

PLA 7123 TPR

PLA 7123 TPKT

420

PLA 7124 P

PLA 7124 PR

PLA 7124 PKT

PLA 7124 TP

PLA 7124 TPR

PLA 7124 TPKT

320

PLA 1053 P

PLA 1053 PR

PLA 1053 PKT

PLA 1053 TP

PLA 1053 TPR

PLA 1053 TPKT

420

PLA 1054 P

PLA 1054 PR

PLA 1054 PKT

PLA 1054 TP

PLA 1054 TPR

PLA 1054 TPKT

320

PLA 1073 P

PLA 1073 PR

PLA 1073 PKT

PLA 1073 TP

PLA 1073 TPR

PLA 1073 TPKT

420

PLA 1074 P

PLA 1074 PR

PLA 1074 PKT

PLA 1074 TP

PLA 1074 TPR

PLA 1074 TPKT

320

PLA 10103 P

PLA 10103 PR

PLA 10103 PKT

PLA 10103 TP

PLA 10103 TPR

PLA 10103 TPKT

420

PLA 10104 P

PLA 10104 PR

PLA 10104 PKT

PLA 10104 TP

PLA 10104 TPR

PLA 10104 TPKT

320

PLA 10123 P

PLA 10123 PR

PLA 10123 PKT

PLA 10123 TP

PLA 10123 TPR

PLA 10123 TPKT

420

PLA 10124 P

PLA 10124 PR

PLA 10124 PKT

PLA 10124 TP

PLA 10124 TPR

PLA 10124 TPKT

320

PLA 1253 P

PLA 1253 PR

PLA 1253 PKT

PLA 1253 TP

PLA 1253 TPR

PLA 1253 TPKT

420

PLA 1254 P

PLA 1254 PR

PLA 1254 PKT

PLA 1254 TP

PLA 1254 TPR

PLA 1254 TPKT

320

PLA 1273 P

PLA 1273 PR

PLA 1273 PKT

PLA 1273 TP

PLA 1273 TPR

PLA 1273 TPKT

420

PLA 1274 P

PLA 1274 PR

PLA 1274 PKT

PLA 1274 TP

PLA 1274 TPR

PLA 1274 TPKT

320

PLA 12103 P

PLA 12103 PR

PLA 12103 PKT

PLA 12103 TP

PLA 12103 TPR

PLA 12103 TPKT

420

PLA 12104 P

PLA 12104 PR

PLA 12104 PKT

PLA 12104 TP

PLA 12104 TPR

PLA 12104 TPKT

320

PLA 12123 P

PLA 12123 PR

PLA 12123 PKT

PLA 12123 TP

PLA 12123 TPR

PLA 12123 TPKT

420

PLA 12124 P

PLA 12124 PR

PLA 12124 PKT

PLA 12124 TP

PLA 12124 TPR

PLA 12124 TPKT

320

PLA 1553 P

PLA 1553 PR

PLA 1553 PKT

PLA 1553 TP

PLA 1553 TPR

PLA 1553 TPKT

420

PLA 1554 P

PLA 1554 PR

PLA 1554 PKT

PLA 1554 TP

PLA 1554 TPR

PLA 1554 TPKT

320

PLA 1573 P

PLA 1573 PR

PLA 1573 PKT

PLA 1573 TP

PLA 1573 TPR

PLA 1573 TPKT

420

PLA 1574 P

PLA 1574 PR

PLA 1574 PKT

PLA 1574 TP

PLA 1574 TPR

PLA 1574 TPKT

320

PLA 15103 P

PLA 15103 PR

PLA 15103 PKT

PLA 15103 TP

PLA 15103 TPR

PLA 15103 TPKT

420

PLA 15104 P

PLA 15104 PR

PLA 15104 PKT

PLA 15104 TP

PLA 15104 TPR

PLA 15104 TPKT

320

PLA 15123 P

PLA 15123 PR

PLA 15123 PKT

PLA 15123 TP

PLA 15123 TPR

PLA 15123 TPKT

420

PLA 15124 P

PLA 15124 PR

PLA 15124 PKT

PLA 15124 TP

PLA 15124 TPR

PLA 15124 TPKT

3/75

3/75

750
1000
1250
750

500
750
1000
1250

1000

500
750
1000
1250

1250

500
750
1000
1250

1500

500
750
1000
1250

Page

3/73

3/73

3/73

3/75

3/8

03_002_013_EN.indd 8

2/4/08 12:40:45

Open plinth-type base


Plain

Ribbed

Self-ventilating top with canopy and open plinth-type base


Transparent

Plain

Ribbed

Handle

Handle

120

180

IP54

IP54

Transparent

PLAZ 553 P

PLAZ 553 PR

PLAZ 553 PKT

PLAZ 553 TP

PLAZ 553 TPR

PLAZ 553 TPKT

PLAZ 554 P

PLAZ 554 PR

PLAZ 554 PKT

PLAZ 554 TP

PLAZ 554 TPR

PLAZ 554 TPKT

PLAZ 573 P

PLAZ 573 PR

PLAZ 573 PKT

PLAZ 573 TP

PLAZ 573 TPR

PLAZ 573 TPKT

PLAZ 574 P

PLAZ 574 PR

PLAZ 574 PKT

PLAZ 574 TP

PLAZ 574 TPR

PLAZ 574 TPKT

PLAZ 5103 P

PLAZ 5103 PR

PLAZ 5103 PKT

PLAZ 5103 TP

PLAZ 5103 TPR

PLAZ 5103 TPKT

PLAZ 5104 P

PLAZ 5104 PR

PLAZ 5104 PKT

PLAZ 5104 TP

PLAZ 5104 TPR

PLAZ 5104 TPKT

PLAZ 5123 P

PLAZ 5123 PR

PLAZ 5123 PKT

PLAZ 5123 TP

PLAZ 5123 TPR

PLAZ 5123 TPKT

PLAZ 5124 P

PLAZ 5124 PR

PLAZ 5124 PKT

PLAZ 5124 TP

PLAZ 5124 TPR

PLAZ 5124 TPKT

PLAZ 753 P

PLAZ 753 PR

PLAZ 753 PKT

PLAZ 753 TP

PLAZ 753 TPR

PLAZ 753 TPKT

PLAZ 754 P

PLAZ 754 PR

PLAZ 754 PKT

PLAZ 754 TP

PLAZ 754 TPR

PLAZ 754 TPKT

PLAZ 773 P

PLAZ 773 PR

PLAZ 773 PKT

PLAZ 773 TP

PLAZ 773 TPR

PLAZ 773 TPKT

PLAZ 774 P

PLAZ 774 PR

PLAZ 774 PKT

PLAZ 774 TP

PLAZ 774 TPR

PLAZ 774 TPKT

PLAZ 7103 P

PLAZ 7103 PR

PLAZ 7103 PKT

PLAZ 7103 TP

PLAZ 7103 TPR

PLAZ 7103 TPKT

PLAZ 7104 P

PLAZ 7104 PR

PLAZ 7104 PKT

PLAZ 7104 TP

PLAZ 7104 TPR

PLAZ 7104 TPKT

PLAZ 7123 P

PLAZ 7123 PR

PLAZ 7123 PKT

PLAZ 7123 TP

PLAZ 7123 TPR

PLAZ 7123 TPKT

PLAZ 7124 P

PLAZ 7124 PR

PLAZ 7124 PKT

PLAZ 7124 TP

PLAZ 7124 TPR

PLAZ 7124 TPKT

PLAZ 1053 P

PLAZ 1053 PR

PLAZ 1053 PKT

PLAZ 1053 TP

PLAZ 1053 TPR

PLAZ 1053 TPKT

PLAZ 1054 P

PLAZ 1054 PR

PLAZ 1054 PKT

PLAZ 1054 TP

PLAZ 1054 TPR

PLAZ 1054 TPKT

PLAZ 1073 P

PLAZ 1073 PR

PLAZ 1073 PKT

PLAZ 1073 TP

PLAZ 1073 TPR

PLAZ 1073 TPKT

PLAZ 1074 P

PLAZ 1074 PR

PLAZ 1074 PKT

PLAZ 1074 TP

PLAZ 1074 TPR

PLAZ 1074 TPKT

PLAZ 10103 P

PLAZ 10103 PR

PLAZ 10103 PKT

PLAZ 10103 TP

PLAZ 10103 TPR

PLAZ 10103 TPKT

PLAZ 10104 P

PLAZ 10104 PR

PLAZ 10104 PKT

PLAZ 10104 TP

PLAZ 10104 TPR

PLAZ 10104 TPKT

PLAZ 10123 P

PLAZ 10123 PR

PLAZ 10123 PKT

PLAZ 10123 TP

PLAZ 10123 TPR

PLAZ 10123 TPKT

PLAZ 10124 P

PLAZ 10124 PR

PLAZ 10124 PKT

PLAZ 10124 TP

PLAZ 10124 TPR

PLAZ 10124 TPKT

PLAZ 1253 P

PLAZ 1253 PR

PLAZ 1253 PKT

PLAZ 1253 TP

PLAZ 1253 TPR

PLAZ 1253 TPKT

PLAZ 1254 P

PLAZ 1254 PR

PLAZ 1254 PKT

PLAZ 1254 TP

PLAZ 1254 TPR

PLAZ 1254 TPKT

PLAZ 1273 P

PLAZ 1273 PR

PLAZ 1273 PKT

PLAZ 1273 TP

PLAZ 1273 TPR

PLAZ 1273 TPKT

PLAZ 1274 P

PLAZ 1274 PR

PLAZ 1274 PKT

PLAZ 1274 TP

PLAZ 1274 TPR

PLAZ 1274 TPKT

PLAZ 12103 P

PLAZ 12103 PR

PLAZ 12103 PKT

PLAZ 12103 TP

PLAZ 12103 TPR

PLAZ 12103 TPKT

PLAZ 12104 P

PLAZ 12104 PR

PLAZ 12104 PKT

PLAZ 12104 TP

PLAZ 12104 TPR

PLAZ 12104 TPKT

PLAZ 12123 P

PLAZ 12123 PR

PLAZ 12123 PKT

PLAZ 12123 TP

PLAZ 12123 TPR

PLAZ 12123 TPKT

PLAZ 12124 P

PLAZ 12124 PR

PLAZ 12124 PKT

PLAZ 12124 TP

PLAZ 12124 TPR

PLAZ 12124 TPKT

PLAZ 1553 P

PLAZ 1553 PR

PLAZ 1553 PKT

PLAZ 1553 TP

PLAZ 1553 TPR

PLAZ 1553 TPKT

PLAZ 1554 P

PLAZ 1554 PR

PLAZ 1554 PKT

PLAZ 1554 TP

PLAZ 1554 TPR

PLAZ 1554 TPKT

PLAZ 1573 P

PLAZ 1573 PR

PLAZ 1573 PKT

PLAZ 1573 TP

PLAZ 1573 TPR

PLAZ 1573 TPKT

PLAZ 1574 P

PLAZ 1574 PR

PLAZ 1574 PKT

PLAZ 1574 TP

PLAZ 1574 TPR

PLAZ 1574 TPKT

PLAZ 15103 P

PLAZ 15103 PR

PLAZ 15103 PKT

PLAZ 15103 TP

PLAZ 15103 TPR

PLAZ 15103 TPKT

PLAZ 15104 P

PLAZ 15104 PR

PLAZ 15104 PKT

PLAZ 15104 TP

PLAZ 15104 TPR

PLAZ 15104 TPKT

PLAZ 15123 P

PLAZ 15123 PR

PLAZ 15123 PKT

PLAZ 15123 TP

PLAZ 15123 TPR

PLAZ 15123 TPKT

PLAZ 15124 P

PLAZ 15124 PR

PLAZ 15124 PKT

PLAZ 15124 TP

PLAZ 15124 TPR

PLAZ 15124 TPKT

3/77

3/77

3/79

3/77

3/79

3/79

3/9

03_002_013_EN.indd 9

2/4/08 12:40:45

Hot-press moulded
polyester enclosures

Selection guide

PLA
TABLE OF MODELS, DIMENSIONS AND REFERENCES
Metal mounting
plate

Insulating mounting plate


Bakelite

Polyester

Universal perforated Set of 2 profiles for


mounting plate
universal chassis

Modular distribution chassis

Nominal dimensions (mm)

Height

Width

500

500
750
1000
1250

750

500
750
1000
1250

1000

500
750
1000
1250

1250

500
750
1000
1250

1500

500
750
1000
1250

Page

Reference

No. of
modules
18 mm

PMR 57

PMA 75

PMR 57

PMB 510

PMA 510

PMR 55 + PMR 55

PMB 510

PMA 510

PMR 55 + PMR 55

PMM 55 + PMM 75

PMB 55 + PMB 75

PMA 55 + PMA 75

PMR 55 + PMR 57

PMM 55 + PMM 75

PMB 55 + PMB 75

PMA 55 + PMA 75

PMR 55 + PMR 57

PMM 75

PMB 75

PMA 75

PMR 75

MOL 75

DLP 57/76

57/76

420

PMM 75

PMB 75

PMA 75

PMR 75

MOL 75

DLP 57/76

57/76

320

PMM 77

PMB 77

PMA 77

PMR 77

MOL 75

DLP 99/132

99/132

420

PMM 77

PMB 77

PMA 77

PMR 77

MOL 75

DLP 99/132

99/132

320

PMM 710

PMB 710

PMA 710

PMR 75 + PMR 75

MOL 75

DLP 57/76 + DLP 57/76

114/152

420

PMM 710

PMB 710

PMA 710

PMR 75 + PMR 75

MOL 75

DLP 57/76 + DLP 57/76

114/152

320

PMM 712

PMB 712

PMA 712

PMR 75 + PMR 77

MOL 75

DLP 57/76 + DLP 99/132

156/208

420

PMM 712

PMB 712

PMA 712

PMR 75 + PMR 77

MOL 75

DLP 57/76 + DLP 99/132

156/208

320

PMM 105

PMB 105

PMA 105

PMR 105

MOL 100

DLP 95/114

95/114

420

PMM 105

PMB 105

PMA 105

PMR 105

MOL 100

DLP 95/114

95/114

320

PMM 107

PMB 107

PMA 107

PMR 107

MOL 100

DLP 165/198

165/198

420

PMM 107

PMB 107

PMA 107

PMR 107

MOL 100

DLP 165/198

165/198

320

PMM 1010

PMB 1010

PMA 1010

PMR 105 + PMR 105

MOL 100

DLP 95/114 + DLP 95/114

190/228

420

PMM 1010

PMB 1010

PMA 1010

PMR 105 + PMR 105

MOL 100

DLP 95/114 + DLP 95/114

190/228

320

PMM 1012

PMB 1012

PMA 1012

PMR 105 + PMR 107

MOL 100

DLP 95/114 + DLP 165/198

260/312

420

PMM 1012

PMB 1012

PMA 1012

PMR 105 + PMR 107

MOL 100

DLP 95/114 + DLP 165/198

260/312

320

PMM 125

PMB 125

PMA 125

PMR 125

MOL 125

DLP 114 P/133

114/133

420

PMM 125

PMB 125

PMA 125

PMR 125

MOL 125

DLP 114 P/133

114/133

320

PMM 127

PMB 127

PMA 127

PMR 127

MOL 125

DLP 198 P/231

198/231

420

PMM 127

PMB 127

PMA 127

PMR 127

MOL 125

DLP 198P/231

198/231

320

PMM 1210

PMB 1210

PMA 1210

PMR 125 + PMR 125

MOL 125

DLP 114P/133 + DLP 114P/133

228/266

420

PMM 1210

PMB 1210

PMA 1210

PMR 125 + PMR 125

MOL 125

DLP 114P/133 + DLP 114P/133

228/266

320

PMM 1212

PMB 1212

PMA 1212

PMR 125 + PMR 127

MOL 125

DLP 114P/133 + DLP 198P/231

312/364

420

PMM 1212

PMB 1212

PMA 1212

PMR 125 + PMR 127

MOL 125

DLP 114P/133 + DLP 198P/231

312/364

320

PMM 155

PMB 155

PMR 155

MOL 150

420

PMM 155

PMB 155

PMR 155

MOL 150

320

PMM 157

PMB 157

PMR 157

MOL 150

420

PMM 157

PMB 157

PMR 157

MOL 150

320

PMM 1510

PMB 1510

PMR 155 + PMR 155

MOL 150

420

PMM 1510

PMB 1510

PMR 155 + PMR 155

MOL 150

320

PMM 1512

PMB 1512

PMR 155 + PMR 157

MOL 150

420

PMM 1512

PMB 1512

PMR 155 + PMR 157

MOL 150

3/95

3/97

3/112

Depth

No. of
doors

320

PMM 55

PMB 55

PMA 55

PMR 55

420

PMM 55

PMB 55

PMA 55

PMR 55

320

PMM 75

PMB 75

PMA 75

420

PMM 75

PMB 75

320

PMM 510

420

PMM 510

320

420

320

3/93

3/94

3/94

(1) Only for enclosures with closed base reference PLA


(2) Only for enclosures with open plinth-type base reference PLAZ

3/10

03_002_013_EN.indd 10

2/4/08 12:40:46

Internal doors

19 fixed
rack

No. of units
1 = 44.45 mm

19 pivoting
rack

Bases (1)

Plinths (2)

Canopies

No. of units
1 = 44.45 mm
PIPLA 55

ZNPLA 53

ZHPLA 53

TJPLA 53

PIPLA 55

ZNPLA 54

ZHPLA 54

TJPLA 54
TJPLA 73

BRF 8 PLA

PIPLA 57

ZNPLA 73

ZHPLA 73

BRF 8 PLA

BRP 7 PLA

PIPLA 57

ZNPLA 74

ZHPLA 74

TJPLA 74

PIPLA 55 + PIPLA 55

ZNPLA 103

ZHPLA 103

TJPLA 103

PIPLA 55 + PIPLA 55

ZNPLA 104

ZHPLA 104

TJPLA 104

PIPLA 55 + PIPLA 57

ZNPLA 123

ZHPLA 123

TJPLA 123

PIPLA 55 + PIPLA 57

ZNPLA 124

ZHPLA 124

TJPLA 124

PIPLA 75

ZNPLA 53

ZHPLA 53

TJPLA 53

PIPLA 75

ZNPLA 54

ZHPLA 54

TJPLA 54

ZNPLA 73

ZHPLA 73

TJPLA 73

BRF 12 PLA

12

PIPLA 77

BRF 12 PLA

12

BRP 11 PLA

11

PIPLA 77

ZNPLA 74

ZHPLA 74

TJPLA 74

PIPLA 75 + PIPLA 75

ZNPLA 103

ZHPLA 103

TJPLA 103

PIPLA 75 + PIPLA 75

ZNPLA 104

ZHPLA 104

TJPLA 104

PIPLA 75 + PIPLA 77

ZNPLA 123

ZHPLA 123

TJPLA 123

PIPLA 75 + PIPLA 77

ZNPLA 124

ZHPLA 124

TJPLA 124

PIPLA 105

ZNPLA 53

ZHPLA 53

TJPLA 53

PIPLA 105

ZNPLA 54

ZHPLA 54

TJPLA 54

ZNPLA 73

ZHPLA 73

TJPLA 73

BRF 17 PLA

17

PIPLA 107

BRF 17 PLA

17

BRP 16 PLA

16

PIPLA 107

ZNPLA 74

ZHPLA 74

TJPLA 74

PIPLA 105 + PIPLA 105

ZNPLA 103

ZHPLA 103

TJPLA 103

PIPLA 105 + PIPLA 105

ZNPLA 104

ZHPLA 104

TJPLA 104

PIPLA 105 + PIPLA 107

ZNPLA 123

ZHPLA 123

TJPLA 123

PIPLA 105 + PIPLA 107

ZNPLA 124

ZHPLA 124

TJPLA 124

PIPLA 125

ZNPLA 53

ZHPLA 53

TJPLA 53

PIPLA 125

ZNPLA 54

ZHPLA 54

TJPLA 54

ZNPLA 73

ZHPLA 73

TJPLA 73

BRF 21 PLA

21

PIPLA 127

BRF 21 PLA

21

BRP 20 PLA

20

PIPLA 127

ZNPLA 74

ZHPLA 74

TJPLA 74

PIPLA 125 + PIPLA 125

ZNPLA 103

ZHPLA 103

TJPLA 103

PIPLA 125 + PIPLA 125

ZNPLA 104

ZHPLA 104

TJPLA 104

PIPLA 125 + PIPLA 127

ZNPLA 123

ZHPLA 123

TJPLA 123

PIPLA 125 + PIPLA 127

ZNPLA 124

ZHPLA 124

TJPLA 124

PIPLA 155

ZNPLA 53

ZHPLA 53

TJPLA 53

PIPLA 155

ZNPLA 54

ZHPLA 54

TJPLA 54

ZNPLA 73

ZHPLA 73

TJPLA 73

BRF 26 PLA

26

PIPLA 157

BRF 26 PLA

26

BRP 25 PLA

25

PIPLA 157

ZNPLA 74

ZHPLA 74

TJPLA 74

PIPLA 155 + PIPLA 155

ZNPLA 103

ZHPLA 103

TJPLA 103

PIPLA 155 + PIPLA 155

ZNPLA 104

ZHPLA 104

TJPLA 104

PIPLA 155 + PIPLA 157

ZNPLA 123

ZHPLA 123

TJPLA 123

PIPLA 155 + PIPLA 157

ZNPLA 124

ZHPLA 124

TJPLA 124

3/118

3/118

3/89

3/85

3/86

3/86

3/11

03_002_013_EN.indd 11

2/4/08 12:40:54

Hot-press moulded
polyester enclosures

Selection guide

PLD-ZD
TABLE OF MODELS, DIMENSIONS AND REFERENCES
Enclosures

Mounting plates

Plinth

Rack

Enclosure dimensions (mm)

Height

Width

Depth

Reference

No. of
doors

No. of
locks

Reference

No. of plates
per enclosure

Reference

Reference

850

465

320

PLD-85/00

APLD-85

ZD-53/00

BPLD

850

590

320

PLD-86/0

APLD-86

ZD-63/0

BPLD

850

785

320

PLD-88/1

APLD-88

ZD-83/1

BPLD

850

1115

320

PLD-812/2

APLD-812

ZD-123/2

BPLD

850

1115

320

PLD-812/2C

APLD-812

ZD-123/2

BPLD

3/123

3/125

Page

3/121

3/121

3/12

03_002_013_EN.indd 12

2/4/08 12:40:56

3/13

03_002_013_EN.indd 13

2/4/08 12:41:00

Insulating modular boxes resistant against outdoor


conditions System 27

3/14

03_014_015_EN.indd 14

2/4/08 12:42:16

Possibility of using
the interior part of the
TPLSP cover (in PLSP
polyester boxes) to fix
the plates using an M5
insert.

2 Side lock (optional),


may be available with
key lock.

Rear view of box with


PF-27 wall-fixing piece
in place.

5 Internal view without


protective panel with
detail of the neutral-earth
terminal block of the
modular chassis.

7 Sealable coverbase lock, screwdriver


operated (standard
supply).

Insulating polyester
mounting plate fixed
to the back. Option of
metallic or bakelite plate.

Box completely
mounted with detail of
hinge, protective panel
and removable blanking
plate fixing.

M6 inserts for fixing


the mounting plate or
various equipment.

3/15

03_014_015_EN.indd 15

2/4/08 12:42:17

SYSTEM 27

Insulating modular boxes


IP55 (EN 60529)

PLS 3654

Insulating modular boxes comprised


of BASES made of fibreglass-reinforced
polyester and COVERS made of
polycarbonate or fibreglass-reinforced
polyester, depending on the model.
PLS and PLSO boxes with polycarbonate
covers on the transparent and opaque
versions.
PLSP boxes with fibreglass-reinforced
polyester covers.
Opaque bases and covers in grey
RAL-7032.

c Modular dimensions that, in addition to its individual use, permit coupling


of boxes.
c Self-extinguishing, double insulation.
c Sealing gasket between base and cover.
c Dielectric rigidity > 5 kV, insulation resistance > .
c Operating temperature from 30 C to 120 C for PLS and PLSO models
and 150 C for PLSP models.
c Easily machined with conventional tools.
c Locking screw, screwdriver operated (standard supply).
c IK09.

3/16

03_016_024_EN.indd 16

2/4/08 12:46:03

Insulating modular boxes


IP55 (EN 60529)

SYSTEM 27

TABLE OF MODELS, DIMENSIONS AND REFERENCES, MODULAR BOXES


High cover boxes

Low cover boxes


Transparent

Opaque

Polyester

Transparent

Opaque

Height
(mm)

Width
(mm)

Depth
(mm)

180

270

180

PLS 1827

PLSO 1827

PLSP 1827

270

270

180

PLS 2727

PLSO 2727

PLSP 2727

270

270

230

PLS 2727 A

PLSO 2727 A

270

360

180

PLS 2736

PLSO 2736

PLSP 2736

270

360

230

PLS 2736 A

PLSO 2736 A

270

540

180

PLS 2754

PLSO 2754

PLSP 2754

270

540

230

PLS 2754 A

PLSO 2754 A

360

360

180

PLS 3636

PLSO 3636

PLSP 3636

360

540

180

PLS 3654

PLSO 3654

PLSP 3654

360

540

230

PLS 3654 A

PLSO 3654 A

360

720

230

PLS 3672 A

PLSO 3672 A

540

540

180

PLS 5454

PLSO 5454

PLSP 5454

540

540

230

PLS 5454 A

PLSO 5454 A

540

720

230

PLS 5472 A

PLSO 5472 A

TABLE OF MODELS, DIMENSIONS AND REFERENCES, BASES AND COVERS


Base 135 mm

Height
(mm)

Width
(mm)

High cover

Low cover
Transparent
45 mm

Opaque 45 mm

Polyester 45 mm

Transparent 95 mm

Opaque 95 mm

Depth
(mm)

180

270

180

FPLS 1827 N

TPLS 1827

TPLSO 1827

TPLSP 1827

270

270

180

FPLS 2727 N

TPLS 2727

TPLSO 2727

TPLSP 2727

270

270

230

FPLS 2727 N

TPLS 2727 A

TPLSO 2727 A

270

360

180

FPLS 2736 N

TPLS 2736

TPLSO 2736

TPLSP 2736

270

360

230

FPLS 2736 N

TPLS 2736 A

TPLSO 2736 A

270

540

180

FPLS 2754 N

TPLS 2754

TPLSO 2754

TPLSP 2754

270

540

230

FPLS 2754 N

TPLS 2754 A

TPLSO 2754 A

360

360

180

FPLS 3636 N

TPLS 3636

TPLSO 3636

TPLSP 3636

360

540

180

FPLS 3654 N

TPLS 3654

TPLSO 3654

TPLSP 3654

360

540

230

FPLS 3654 N

TPLS 3654 A

TPLSO 3654 A

360

720

230

FPLS 3672 N

TPLS 3672 A

TPLSO 3672 A

540

540

180

FPLS 5454 N

TPLS 5454

TPLSO 5454

TPLSP 5454

540

540

230

FPLS 5454 N

TPLS 5454 A

TPLSO 5454 A

540

720

230

FPLS 5472 N

TPLS 5472 A

TPLSO 5472 A

TABLE OF MODELS, DIMENSIONS AND REFERENCES, PLATES AND CHASSIS


Mounting plates
Metal

Modular chassis
Polyester

Bakelite
To be coupled to boxes
(dimensions)

To be coupled to boxes
(dimensions)
Height (mm)

Width (mm)

Height (mm)

Width (mm)

Reference

No. of modules

180

270

PMM 1827

PMA 1827

PMA/B 1827

180

270

DL 27/12

12

270

270

PMM 2727

PMA 2727

PMA/B 2727

270

270

DL 27/24

24

270

360

PMM 2736

PMA 2736

PMA/B 2736

360

270

DL 27/24-2
DL 27/36

24
36

540

270

DL 27/48

48

270

540

PMM 2754

PMA 2754

PMA/B 2754

360

540

PMM 3636

PMA 3636

PMA/B 3636

360

540

PMM 3654

PMA 3654

PMA/B 3654

360

720

PMM 3672

PMA 3672

PMA/B 3672

540

540

PMM 5454

PMA 5454

PMA/B 5454

540

720

PMM 5472

PMA 5472

PMA/B 5472

3/17

03_016_024_EN.indd 17

2/4/08 12:46:05

Insulating modular boxes


IP55 (EN 60529)

SYSTEM 27

Dimensions (mm)
3654
180
110

138

200

45

2.3
12

360
290

249

122.2

5
260

138

95

45

2.3
12

540
70

249

249

270
200

2.3
12

2 3*

122.2

122.2

3672
720
70

2.7

699
339

339

5
350

2.7

339

122.2

12

3.5

138

95

3
339

5472
720
70

260

260

249

519

3
519

95

540
70

45

2
249

138

200

2.7
12

122.2

2.5 3* 2.5

200

540
70

200

2754

290

260

290

270
200

122.2

4
350

699

2.7

260

360
290

12
2

95

45
360
290

138

138

290

339

360
290

3636

200

5
260

290

95

2.7
12

6
260

339
3
339

519

260

95

45

1
4

45

519

200
200

138

2736
360
290

2 3*

122.2

138

200

540
70

249
3
249

249

249

200
2

122.2

4
260

5454

1
270
200

2.7
12

270
200

519

260

2727

95

4
159

45

339

249

270
200

159

138

200

339

2
1

540
70

339

1827

12
6
350

122.2

5
350

* The thickness of 3 mm corresponds to the polyester cover.

A Coupling to the back with low cover.


B Coupling to the back with high cover..
C D Interior view of back corner, detail of the bosses with M6
inserts.
E F Interior view of the corner of the polyester cover with
housing for the expandable nut.
Ref.: TE-25 for M5 screws.

3/18

03_016_024_EN.indd 18

2/4/08 12:46:06

SYSTEM 27

Insulating modular boxes


IP65 (EN 60529)

S27-DL/48

Example of coupling
Suite of general, busbar, meter and distribution boxes.

PS 2C-27

TL-27/270

EGB-27

UM-27/270

UM-27/270

Cover TL-27/270 with


cable glands

TL-27/270

All boxes may be coupled on any of their sides. The


coupling may be done using UM modular joints and
PS fastening pieces.

3/19

03_016_024_EN.indd 19

2/4/08 12:46:08

SYSTEM 27

Composition accessories

Openings
To order boxes with lateral openings, you must add the numbers of the sides
that you wish to have cut to the reference of the basic box.
These numbers are indicated on the dimensions panel as well as raised on
the bases themselves. Example: a 270 540 mm box with low transparent
cover and openings on sides 1, 3 and 5 would be: PLS-2754/1-3-5.

Side cut-out press, Ref.: PUC-27.

Modular couplings
Manufactured with fibreglass-reinforced polycarbonate. Pieces prepared for
coupling the boxes on any of their lateral sides.
c Sealing gasket on both sides.
c Supplied with all the hardware necessary for fixing and the openings template.

To couple to openings (mm)

Reference

110 (nominal 180)

UM 27/180

200 (nominal 270)

UM 27/270

290 (nominal 360)

UM 27/360

3/20

03_016_024_EN.indd 20

2/4/08 12:46:10

SYSTEM 27

Composition accessories

Box coupling pieces


For coupling 2, 3, or 4 boxes with the possibility of wall fixing.
To couple

Reference

2 boxes

PS2C-27

3 or 4 boxes

PS4C-27

M618 cylinder head screws.

Side covers
Manufactured with fibreglass-reinforced polyester. Easily machined with
conventional tools for cable entry.
c With a sealing gasket.
c Supplied with all the hardware necessary for fixing and the openings template.

To couple to openings (mm) )

Reference

200 (nominal 270)

TL 27/270

290 (nominal 360)

TL 27/360

Material

Reference

Wall-fixing parts

Passivated zinc-coated steel

PF-27

Stainless steel

PF-27/ I

3/21

03_016_024_EN.indd 21

2/4/08 12:46:11

SYSTEM 27

Composition accessories

Post fixing
Has incorporated all the elements necessary for fixing and adjusting to a post.
To couple to module width (mm)

Reference

270

FSP-27/270

360

FSP-27/360

540

FSP-27/540

Rail-fixing pieces
Rail fixing

Direct wall-fixing

Rail
CNT-20
Nut
BN-206

M630
cylinder head screw

Stud
8

50 mm long ribbed
head screw

Transport handle
Material

Reference

Polyamide

ATM-27

3/22

03_016_024_EN.indd 22

2/4/08 12:46:13

SYSTEM 27

Composition accessories

Locks for insulated modular boxes


TCD-27/4 N

Types of operation with

Specifications

TCM-27/4 N
Set of 4 locks

Screwdriver

TCD-27/4 N

Screwdriver

TCD-27/6 N

Set of 8 locks

Screwdriver

TCD-27/8 N

Set of 4 locks

Manual

TCM-27/4 N

Set of 6 locks

CL-27

Set of 6 locks

Standard supply in boxes (PLS)

Standard in boxes (S27DL)

Set of 8 locks

TCT-27/4 N

PPA-27
CLL-27

Reference

Manual

TCM-27/6 N

Manual

TCM-27/8 N

Set of 4 triangle locks

LT-27

TCT-27/4 N

Set of 6 triangle locks

LT-27

TCT-27/6 N

Set of 8 triangle locks

LT-27

TCT-27/8 N

Double bar side lock, possibility


of fixing the wing key to the lock

DBP

CL-27

Side lock with key operation

CLL-27

Metal sealing sheet


(included in standard supply)

PPA-27

Insulated seal

PPS-27

Triangle key

LT-27

LT-27

Windows for automatic switches


Allow access to the interior of the enclosure, maintaining the IP65 degree of
protection.
Made of transparent polycarbonate.
C

Reference
Low cover

Fig. 1

High cover

No. of
modules

Fig. No.

VA 27/2M

VA 27/2MA

78

60

Low cover High cover


15

25

VA 27/4M

VA 27/4MA

78

95

15

25

VA 27/6M

VA 27/6MA

78

130

15

25

VA 27/8M

VA 27/8MA

78

165

15

25

VA 27/10M

VA 27/10MA

10

78

200

15

25

VA 27/12M

VA 27/12MA

12

78

235

15

25

VA 27/16M

16

195

165

13

VA 27/24M

24*

196

235

13

VA 27/36M

36*

248

235

13

VA 27/51M

51**

248

325

13

* In rows of 12 modules mounted vertically.


** In rows of 17 modules mounted horizontally.
Fig. 2

Fig. 1

Fig. 2

3/23

03_016_024_EN.indd 23

2/4/08 12:46:14

SYSTEM 27

Mounting accessories

Plates for meters


Mounting plates for fixing single-phase or three-phase meters made of polyester
with fibre-glass, in RAL-7032.
To couple to boxes
Height

Width

270

270

270

360

270

540

Single-phase
No. of meters

Three-phase

Reference

No. of meters

Reference

1M

P1M-27

1M (displaced)

P1M-P27

1M

P1M-2736

1T

2M

P2M-27

2M

P2M-27E

1T

P1T-27E(1)

2M (vertical)

P2M-27V

3M

P3M-27

P4M-27V

2T

P2T-27

P1T-27

360

540

4M
-

3T

P3T-27

540

540

6M

P6M-27V

2T

P2T-27E

3T

P3T-27E

360
540

720
720

5M

P5M-27

3T

P3T-27H

6M

P6M-27V

4T

P4T-27

8M

P8M-27

3T

P3T-27G

9M

P9M-27

6T

P6T-27

10M

P10M-27

(1) 1 vertical three-phase.

Fixing nuts
Metal insert nuts for fixing equipment on polyester and bakelite insulated
mounting plates.
Reference

Thread M

TE-3

TE-4

TE-5

TE-6

TE-8

TE-10

10

TE-12

12

3/24

03_016_024_EN.indd 24

2/4/08 12:46:17

SYSTEM 27

Current distribution accessories

Adjustable ties
Made of 6.6 nylon in natural colour or black for outdoor conditions.
Reference

Use
L

minimum

maximum

White

Black

LZ25100

LN25100

100

2.5

1.6

22

LZ25200

LN25200

200

2.5

1.6

49

LZ35150

LN35150

150

3.5

1.6

35

LZ35200

LN35200

200

3.5

1.6

49

LZ35300

LN35300

300

3.5

1.6

75

LZ46150

LN46150

150

4.6

1.6

36

LZ46200

LN46200

200

4.6

1.6

49

LZ48270

LN48270

270

4.8

1.6

73

LZ46390

LN46390

390

4.6

1.6

109

LZ76390

LN76390

390

7.6

4.7

108

Tightening tools
To tighten and cut the adjustable ties to size. They facilitate wiring and save
time, preventing the packets of cables from loosening.
Tool adjustable according to the thickness of the tie. Can be used with the
following models: LZ25100 up to LZ46390. Ref.: MARK3.
A very light and ergonomic tool, the cut on the tie is done by twisting the
tool. Can be used on the following models of ties: LZ25100 up to LZ46390.
Ref.: MARK20, 21.
Reference
MARK3

Admissible width ties


2.5 4.8

Reference

Admissible width ties

MARK20

2.5 4.8

MARK21

4.6 7.6

3/25

03_025_037_EN.indd 25

2/4/08 12:47:45

SYSTEM 27

Current distribution accessories

Locking clips
Allows fixing ties from the series LZ25100 up to LZ46390 on panels up to
3.2 mm thick. Material: 6.6 nylon.
perforation
mm

Max. panel
thickness mm

SFC1

3.2

SFC2

Reference

SFC2

SFC1

Fig. 1

Figure

Fig. 2

Stud
To use with soft materials: 7 mm hole, or hard materials: 8 mm hole.
Ties up to 9 mm in width can be coupled. Material: black 6.6 nylon.
Ref.: LOK01.

Tie fixing support


To attach one or two ties, mounted with a single screw. Material: 6.6 nylon.
Allows for attaching ties from the entire range.
Reference

Fixing screw

Admissible width
ties

KR6

12

18

M4

2.5 4.8

KR8

14.5

25

12

M6

2.5 7.6

3/26

03_025_037_EN.indd 26

2/4/08 12:47:46

SYSTEM 27

Current distribution accessories

Support heads
To transform normal ties into ties with fixing heads, introduce a tie into this
head before closing it on the cable bundle. Material: 6.6 nylon.

Fixing screw

Admissible width
ties

FH18

7.1

13.3

M4

2.5

FH30

9.5

17.9

4.7

M5

3.5

FH50

11.3

22.2

6.2

M6

4.7

Reference

Self-adhesive support base


Permits insertion of 1 tie from 4 points at a 90 angle. Attaches ties from the
series LZ25100 up to LZ46390. Material: 6.6 nylon.
E

Admissible width
ties

3.2

13.2

2.5 3.5

20.2

2.5 4.8

MB3A

19.1

19.1

4.8

MB4A

28.5

28.5

5.5

Reference

adhesive support

Tie fixing support


To attach ties from any series. Material: 6.6 nylon.
Reference
LKC

Admissible width
ties mm
2.5 7.6

Fixing screw
M5

3/27

03_025_037_EN.indd 27

2/4/08 12:47:48

SYSTEM 27

Current distribution accessories

Lateral tie fixing support


Covers the head of the tie in its end, thus obtaining neater cabling.
Material: 6.6 nylon.
Reference

Admissible width
ties mm

LKM/HE

2.5 7.6

Fixing screw
M5

Fixing loop for tubes, hoses, etc.


2 versions, fixed and adjustable, from 5 to 25.4 mm. Material: black 6.6
nylon.
Reference

A
min. - max.

NX1

3.5

6.2

13.7

NX3

3.9

9.4

20.5

NX5

12

3.9

9.4

24

NX8*

14.3 15.8

1.3

12.6

32

NX11

17.4 20

1.3

12.6

37

NX14

22.2 25.4

4.3

1.5

16

45

*The NX8 model only has 3 adjustment holes.

NX 1-3-5

NX 8-11-14

Membrane gland
For tube or cable entry. Models EGB-27 made of neoprene.

3/28

03_025_037_EN.indd 28

2/4/08 12:47:49

SYSTEM 27

Current distribution accessories

Adjustable membrane glands


Insulating membrane glands made of PVC with entry that can be adjusted
for cables or tubes (see page 3/30).

Fig. 1

Fig. 2

Capacity
Reference

Fig.

B*

F
Tube

cable
ECPC-3

25

21.5

18

3.2

13

5 to 18

Pg 9 to 11

ECPC-5

33

29.5

26

3.2

20

5 to 26

Pg 9 to 16

ECPC-6

43

38.5

36

3.2

22

5 to 36

Pg 9 to 21

ECPC-9

70

63

60

28

20

28 to 60

Pg 21 to 48

ECPC-15

98

90

87

28

23

28 to 87

Pg 21 to 48

* Mounting perforation.

Protective sleeves
Small protective sleeves for cables coming out of tubes, as indicated in the
instructions for MI BT 019. Made of flexible and durable PVC, in light grey
colour.
Reference

Tube

12.7

Pg 9

PC-2

18.6

16

Pg 11

PC-3

20.4

17.8

Pg 13.5

PC-4

22.5

19.8

Pg 16

PC-5

28.3

25.3

Pg 21

PC-6

37

33.6

Pg 29

PC-7

47

43

Pg 36

15.2

PC-1

3/29

03_025_037_EN.indd 29

2/4/08 12:47:50

SYSTEM 27

Current distribution accessories

Useful information about Pg tubes and HIMEL accessories to be coupled


MODELS, DIMENSIONS AND REFERENCES
Tubes

HIMEL accessories to be coupled


perforations to

interior
Designation

exterior

Steel
Flexible
steel

PVC

Cables inserted*
Flexible
steel with
PVC

2.5

Insert

Thread

4
Pg 9

15.2

12.7

12.4

12

11.1

To the perforations

To the tube

No. of conductors

Adjustable
membrane glands

Protective
sleeves

Adjustable
membrane
glands

Plain plugs

EC-1 to EC-7
16

14

ECPC-3 to ECPC-6

PC-1

PC-2

EC-2

ECN-5 to ECN-10
Pg 11

18.6

16

15.5

14.5

10

2.5

14.2

16

EC-2 to EC-7
4

2.5

19

17.5

25

ECPC-5; ECPC-6

EC-1

ECN-5 to ECN-10
EC-3 to EC-7

Pg 13.5

20.4

17.8

17.5

16.3

16

35

10

21

19.5

ECPC-5; ECPC-6

TC-1

ECN-1
EC-3
PC-3

ECPC-3

TC-2

PC-4

EC-4

TC-3

PC-5

ECPC-5

ECN-5 to ECN-10
EC-4 to EC-7
Pg 16

22.5

19.8

18.7

18.5

17.6

50

16

10

23

21.5

ECPC-5; ECPC-6
ECN-5 to ECN-10
EC-5 to EC-7

Pg 21

28.3

25.3

24.7

23

23

70

25

16

10

29

27

ECPC-6 to ECPC-15

EC-5

ECN-6 to ECN-10
Pg 29

37

33.6

33.5

31

31

95

35

25

16

120

50

35

25

EC-6; EC-7
38

35.5

150
47

43

41.5

41

40.3

240

35
70

50

50

48

45.5

Pg 48

54
60

50
56

48
54.2

48
52.5

47
51.4

EC-6

TC-5

ECPC-6

TCP-5

ECN-6

EC-7

300
Pg 42

PC-6

ECN-7; ECN-10

185
Pg 36

ECPC-9; ECPC-15

TC-4

ECN-5

EC-7

ECPC-9; ECPC-15

PC-7

ECN-7

TC-6

ECN-10
95

70

120

95

70

120

95

150

120

150

ECPC-9; ECPC-15
55

52.5

ECN-10

ECPC-9; ECPC-15
61

58

ECN-10

* Number and section in mm2 of the conductors that may be housed inside each tube (orientative).
For more information, consult the electrotechnical rules for low voltage (MI BT 019).

Insulators
To form busbars. Made of fibreglass-reinforced polycarbonate.

ASE 27/360

AE-25

To couple to the side of


box (mm)

AI-25

No. of plates

Plate width (mm)

Reference

360

15/20

ASE 27/360

270

15/20

AE 25

15/20/30

AI 25

3/30

03_025_037_EN.indd 30

2/4/08 12:47:51

SYSTEM 27

Current distribution accessories

Split bridges
Cable section mm2

Reference

95

TS-25/95

150

TS-25/150

240

TS-25/240

Sigma safety terminals


Base of safety terminals made of black matte self-extinguishing polyamide-6;
terminal of brass MS-58
(DIN17660); ring of tempered steel zinc dichromate; cap made of orange
self-extinguishing polypropylene.
c Anti-cut. The connection is made using a tightening mechanism that
spreads the pressure out throughout the entire contact surface, avoiding
the occasional rubs and stresses that damage the conductors.
c Loosening proof. The ring that surrounds the brass body ensures that the
pressure exerted by the conductors cannot open the terminal and loosen
the connection.
c Total insulation. All the SIGMA terminals are supplied with a terminal cap,
avoiding any accidental contact with live parts.
All the calibres may be coupled one to the other, allowing the formation of
strips of any length. Service voltage: 500 V.

Reference

Section
m/m2

S.04

14

30

20

13

21

S.06

16

33

25

16

24

S.10

1 10

38

28

16

28

S.16

1 16

42

32

19

32

S.25/35

1 35

46

38

23

34

11

S.50

1 50

52

45

27

40

15

S.70

1 70

55

50

30

40

15

S.95/100

1 100

58

54

33

40

20

NOTE: each terminal accepts up to 2 conductors of the section indicated.

3/31

03_025_037_EN.indd 31

2/4/08 12:47:52

SYSTEM 27

Current distribution accessories

Bypass terminal blocks


Earth and neutral bypass terminal blocks with insulated plinth.
Direct fixing by pressure on the profile supplied by the chassis itself.
Number of terminals section in (mm2)

Reference
RBLZ/21656*

2 16 mm2 + 5 6 mm2

RBLZ/21686

2 16 mm2 + 8 6 mm2

RBLZ/216146

2 16 mm2 + 14 6 mm2

RBLZ/216296

2 16 mm2 + 29 6 mm2

* Included in standard supply.

Bimetal BBH terminals


BBH-29

Terminals especially designed for branching cables on plates; their main


application is busbar connection.

BBH-29D

BBH terminals are made of a tinned, hot cast copper alloy and are suitable
for connecting to a conductor of copper or aluminium indistinctly (bimetal).

Main section
(mm2)

Bypass section
(mm2)

BBH-29

6-50

BBH-29C*

6-50

BBH-30

10-95

BBH-31

16-150

BBH-32

50-240

6-50

6-50

Reference

BBH-29D

BBH-29P

BBH-29DP

BBH-29DC*

6-50

6-50

BBH-30D

10-95

10-95

BBH-31D

25-150

16-150

BBH-32D

95-240

5-240

Reference

Main section
(mm2)

Bypass section
(mm2)

BBH-29P

6-50

BBH-29PC*

6-50

BBH-29DP

6-50

6-50

BBH-29DPC*

6-50

6-50

* Include terminal cover CBBH-29.

Plate/cable terminals
Plate entry and bypass by cable.
Cable bypass
section (mm2)

Plate thickness (mm)

Figure

BPCH 516

1.5 to 16

BPCH 550

1.5 to 50

Reference

BPCH 5120

BPCH 1016

1.5 to 16

10

BPCH 1050

1.5 to 50

10

10

BPCH 10120

16 to 120

16 to 120

3/32

03_025_037_EN.indd 32

2/4/08 12:47:53

Natural ventilation accessories


Complementary accessories

SYSTEM 27

Ventilation devices
To connect the inside of the enclosure with the exterior atmosphere and
prevent condensation.

Specifications

VM-25

Reference

19

VM-25

29

VM-27

VM-27

3/33

03_025_037_EN.indd 33

2/4/08 12:47:58

SYSTEM 27

Applications

Insulating modular boxes with distribution chassis

S27 DL/48

Modular PLS boxes composed of base


and transparent low cover, with hinges
and manually-operated and screwdriveroperated locks.
DL incorporated chassis composed of
automatic DIN-35 rails, insulated panel
protector and neutral-earth terminal
blocks of 2 16 + 5 6 mm2.

c Opening for cable entry with TL cover.


c Double-insulation mounting.
c Excellent resistance to corrosive environments.
c Exterior hinges, allowing a door opening of approximately 180.
c Removable blanking plate with a width of 36 mm (2 modules), standard
supply one per row.
c A lateral double bar lock CL-27 or key CLL-27 can be incorporated.

3/34

03_025_037_EN.indd 34

2/4/08 12:47:58

SYSTEM 27

Applications

TABLE OF MODELS, DIMENSIONS AND REFERENCES


External dimensions (mm)
Reference
Height
(A)

Width
(B)

Depth
(C)

Total capacity in 18 mm
modules

No. of rows

Approx. weight (kg)

180

270

180

S27 DL/12

12

1.7

270

270

180

S27 DL/24

24

2.5

360

270

180

S27 DL/24-2

24

2.7

360

270

180

S27 DL/36

36

2.8

540

270

180

S27 DL/48

48

3.8

Dimensions (mm)
S27 DL/12

S27 DL/36

S27 DL/24

S27 DL/48

S27 DL/24-2

3/35

03_025_037_EN.indd 35

2/4/08 12:47:59

SYSTEM 27

Applications

Blanking plate
Blanking plate in self-extinguishing insulating material for total or partial
coverage of the window for automatic switches.
c Easily cut to the desired size.
No. of modules

Reference

Length (mm)

ATP6/DTM

108

24

ATP24/DTM

432

Cut to size

ATP/UND

1100

Distribution bars
For the distribution in a single row of automatic switches with a total of
12 modules.
1

2
No. of bars

No. of poles
per bar

Reference

Figure No.

12

BDS 1/12

BDS 2/6

BDS 3/4

BDS 4/3

3/36

03_025_037_EN.indd 36

2/4/08 12:48:02

3/37

03_025_037_EN.indd 37

2/4/08 12:48:04

POLYMEL polyester monobloc enclosures

The built-in canopy


protects the door and
the sealing gasket.

Enclosure with
a tempered glass
transparent door,
maintaining the IP66
and IK08 (5J) degrees of
protection.

12

11

10

9 Depth adjustable
mounting plate supports
with positions every
12.5 mm.

3/38

03_038_039.indd 38

21/2/08 10:23:10

Wall fixing from the


outside with stainless
steel or polyester wall
brackets.

3 The fixing strips,


notched every 25 mm,
located at the back
of the enclosure allow
direct attachment of
mounting rails or other
devices, thus reducing
assembly time.

The lock system is


located outside the
sealed area to maintain
the IP66 degree of
protection.

7 Interior hinges fixed


into the door. The built-in
polyurethane sealing
gasket guarantees IP66.

10 Direct wall fixing with


a plug to maintain the
double insulation and
watertightness.
4 inserts at the back
for fixing the mounting
plate.

11

12

Reversible polyester
internal door with grid
pattern for industrial
control.

Four moulded bosses


on the inside of the
door help to assemble
accessories.
For maximum usable
space, the door has a
grid pattern for centring
components. Door
opening more than 180.

Ventilation louvers
provide natural
ventilation of the
interior of enclosure,
thus preventing
condensation.

Self-ventilation
windows at the rear of
the enclosure.

3/39

03_038_039.indd 39

21/2/08 10:23:12

POLYMEL

PLM-75

Hot-press moulded fibreglass-reinforced


polyester enclosure, in grey RAL-7032.

Polyester enclosures
IP66 (EN 60529)

PLM-75/CME

Construction specifications
c Body of one single piece: monobloc.
c Fully reversible.
c Intended for use in both indoor and outdoor environments.
c A wide range of accessories enabling use in distribution, control and
measurement panels for industrial and infrastructure facilities.
c Standard double bar lock or three-point lock with handle (without insert).
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and
EN 62208.
c IP66 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20 J) conforming to IEC and
EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960).
c Extreme operating temperatures from 50 to +150 C.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.

3/40

03_040_050_EN.indd 40

2/4/08 12:50:10

Polyester enclosures
IP66 (EN 60529)

POLYMEL

TABLE OF MODELS, DIMENSIONS AND REFERENCES


External dimensions
(mm)

Height
(A)

Plain
door

Transparent
door

Plain
door

No. of
locks

Transparent
door

Plain
door

With
insulating
mounting
plate

Adjustable
Modular Internal
plate
chassis door
support

Mounting plates

Width
(B)

Depth
(C)

310

215

160

PLM-32*

PLM-32/KT*

PLM-32MB

308

255

160

PLM-3025

PLM-3025/KT

PLM-3025MB

430

330

200

PLM-43

PLM-43/KT

PLM-43/CME

PLM-43 KT/CME

PLM-43MB

530

430

200

PLM-54

PLM-54/KT

PLM-54/CME

PLM-54 KT/CME

PLM-54MB

647

436

250

PLM-64

PLM-64/KT

PLM-64/CME

PLM-64 KT/CME

PLM-64MB

747

536

300

PLM-75

PLM-75/KT

PLM-75/CME

PLM-75 KT/CME

PLM-75MB

847

636

300

PLM-86

PLM-86/KT

PLM-86/CME

PLM-86 KT/CME

PLM-86MB

1056

852

350

PLM-108 (1)

PLM-108KT(1)

PLM-108MB

Standard double bar lock

Three-point lock with handle


(without insert)

Metal

Insu- Microperlating forated Universal

* PLM-32 model in polycarbonate.


(1) Four-point locking system.

3/41

03_040_050_EN.indd 41

2/4/08 12:50:13

Polyester enclosures
IP66 (EN 60529)

POLYMEL

Dimensions (mm)

PLM- ENCLOSURE DIMENSIONS


(EXCEPT PLM-3025)

PLM-32...108
Reference PLM-...

C
M8

310

430

530

647

747

847

1056

215

330

430

436

536

636

852

160

200

200

250

300

300

350

310

280

380

480

580

680

864

215

200

300

300

400

500

694

270

380

480

580

680

780

980

170

260

360

360

460

560

760

225

325

425

525

625

725

925

125

225

325

325

425

525

725

275

375

475

575

675

775

975

75

150

250

250

350

450

650

13

13

13

15

15

15

144

181

181

228

278

278

327

2.3

2.7

2.9

2.9

132

179

279

279

379

479

684

129

168

168

212

261

261

304

186

247

347

388

487

587

776

A
B

108

I
N
M8

86

75

64

54

43

32

K
8

16

PLM-3025

3/42

03_040_050_EN.indd 42

2/4/08 12:50:14

POLYMEL

Composition accessories

Enclosure fastening ties


For the lateral or vertical coupling of two enclosures.
c Made of fibreglass-reinforced self-extinguishing polyester.
c Sealing gasket built in, which guarantees the IP66 degree of protection.
c Mounting with screws (included in the standard supply).

Type of coupling

PLM-75 y 86

lateral

BU/PLM

PLM-108

lateral

BU-108/PLM

185

148

For attachment to enclosures

Reference

398/635

Floor-mounting pillar
For the protection of cabling of outdoor installations, distribution panels for
campgrounds, leisure harbours, etc. at which it is necessary to maintain a
distance between the installation and the floor. Manufactured with fibreglassreinforced polyester.
c Steel frame for fixing to the floor.
c Easy installation.
c High impact resistance.

For attachment to enclosures

Reference

PLM-54

SFS/PLM

PLM-64

165

200

130

355

160100

800

Floor fixing using a frame (1)

165

251

405

Fixing to the enclosure

160100

200

(1) Frame supplied

3/43

03_040_050_EN.indd 43

2/4/08 12:50:14

POLYMEL

Composition accessories

Cable entry plate


Plain polyester cable entry plates, with sealing gasket and fastening hardware.

For attachment to enclosures

Reference

PLM-75/86/108

TLA-4420

PLM-108

TLA-6420

Wall fixing
Wall fixing can be done directly by drilling the back of the enclosure or with
the PF/PLM polyester brackets or PFI/PLM stainless steel brackets. The
brackets are mounted from the exterior to the back of the enclosure, using
inserts and M8 screws (included in the standard supply).

PFI/PLM

Model PLM-32 is mounted using self-tapping screws.


The fixing pieces can be positioned vertically or horizontally.
The set is not included in the standard supply of the enclosure.

H2

PFI/PLM

PF/PLM

H1

V1

V2

15 8*
* For PLM-32 model
and PFI/PLM

Fixing centres (mm)


For attachment
to enclosures

Horizontal position

Reference
Insulated

Vertical position

Stainless steel

Height (H1)

Width (H2)

Height (V1)

Width (V2)

PLM-32

PF/PLM-32

247

239

334

152

PLM-3025

PF/PLM

275

355

410

220

PLM-43

PF/PLM

PFI/PLM

355

360

490

225

PLM-54

PF/PLM

PFI/PLM

455

460

590

325

PLM-64

PF/PLM

PFI/PLM

555

465

690

330

PLM-75

PF/PLM

PFI/PLM

655

565

790

430

PLM-86

PF/PLM

PFI/PLM

755

665

890

530

PLM-108

PF/PLM

PFI/PLM

955

885

1090

750

3/44

03_040_050_EN.indd 44

2/4/08 12:50:16

POLYMEL

Composition accessories

Post fixing set


Allows the enclosure to be fixed to concrete, wood or aluminium posts up to
diameters of 675 mm.
c For exterior installations, provisional works or fairs, public lighting panels, etc.
c Galvanised steel fixing loop and profiles.
c Profiles attach to the back of the enclosure using M8 screws in the inserts
(included in the standard supply).
c Recommended maximum weight of the installation: 100 kg.

For attachment to enclosures

Reference

PLM-43

SFP-300

PLM-54 and PLM-64

SFP-400

PLM-75

SFP-500

PLM-86

SFP-600

PLM-108

SFP-800

Internal doors
Internal door set in fibre-glass reinforced polyester, except model PI-3025/PLM,
made of sheet steel finished with polyester-epoxy RAL-7032 paint.
Insulating door specifications:
c Self-extinguishing.
c Grid pattern on the inside of the door for alignment of equipment.
c Quick locking through 1/4 turn sealable screws.
c Door opens in both directions.

Reference

PI-3025/PLM*

248

165

62

76

PIP-43

315

205

152

26

PIP-54

415

305

152

26

PIP-64

515

305

194

32

PIP-75

615

405

244

32

PIP-86

715

505

244

32

PIP-108

850

650

269

37

* Plain internal door, dimensions A and B corresponding to the usable surface of the door.

3/45

03_040_050_EN.indd 45

2/4/08 12:50:17

POLYMEL

Composition accessories

Spare doors
Doors to be changed or repositioned on PLM enclosures.
c Made of fibreglass-reinforced self-extinguishing polyester in grey RAL-7032.
c For maximum usable surface, the plain door has a grid pattern for centring
components.
c Door opening to > 180.
Type of door

For attachment to enclosures


Plain

Transparent

PLM-3025

PUPLM-3025

KTPLM-3025

PLM-43

PUPLM-43

KTPLM-43

PLM-54

PUPLM-54

KTPLM-54

PLM-64

PUPLM-64

KTPLM-64

PLM-75

PUPLM-75

KTPLM-75

PLM-86

PUPLM-86

KTPLM-86

PLM-108

PUPLM-108

KTPLM-108

Locks for polyester enclosures


Locks up to PLM-86
Standard double bar lock, with zinc-alloy inserts, operation with LDB 5
or DBP wing key (conforming to DIN 43668).
Reference: CDB/PLM.
TRANSFORMING INSERT OF STANDARD LOCK INTO STANDARDISED VERSIONS
Specifications

Type of key operation ref.

Reference

v 6 mm square lock

LC-7

v 7 mm square lock

LC-7

TC7/CRN

v 8 mm square lock

LC-8

TC8/CRN

Triangle lock with 6.5 mm side

LT-8

TT7/CRN

Triangle lock with 8 mm side

LT-8

TT8/CRN

TC6/CRN

Handle lock with 405 key

TL/PLM

Handle lock with key 220

TL220/PM

Stainless steel padlocking


device (up to PLM 86)

KPLM

Fixed wing lock

CDB/PLM

Double bar wing

DBP

3/46

03_040_050_EN.indd 46

2/4/08 12:50:18

POLYMEL

Composition accessories

PLM... CME locks


Standard handle locks without insert in models PLM CME.
LOCKS (INSERTS) FOR PLM...CME ENCLOSURES
Specifications

Type of key operation ref.

Reference

Double bar lock

LDB 5

TDB/PLD

Triangle lock with 8 mm side

LT-8

TT7/PLD

Lock with key type 405

TCL/PLD

Key-operated Lock
Reinforced type

TLR/PLD

Key-operated Lock

TJIS/PLD

Padlock lock

BCME/PL

Manual lock

TEM/PLD

Four-point locks for PLM-108


Standard double-bar lock for model PLM-108 in its plain door and KT
transparent door versions. Operation with LDB 5 key
or DBP wing
key (conforming to DIN 43668).
TRANSFORMATION FROM FOUR-POINT LOCK TO DIFFERENT TYPES OF
LOCKS OR FOR ENCLOSURES
Specifications

Type of key operation ref.

Reference

v 6 mm square lock

LC-7

v 7 mm square lock

LC-7

TC 7/PL

v 8 mm square lock

LC-8

TC 8/PL

Triangle lock with 7 mm side

LT-8

TT 7/PL

Triangle lock with 8 mm side

LT-8

TT 8/PL

TC 6/PL

Padlocking device

BC/PL

STANDARD TRANSFORMATION FOR PLM-108 ENCLOSURE RETRACTABLE


HANDLE LOCK WITH DIFFERENT TYPES
Specifications

Type of key operation ref.

Reference

Double bar lock

LDB 5

v 6 mm square lock

LC-7

TEDB/PL
TEC 6/PL

v 7 mm square lock

LC-7

TEC 7/PL

v 8 mm square lock

LC-8

TEC 8/PL

Triangle lock with 7 mm side

LT-8

TET 7/PL

Triangle lock with 8 mm side

LT-8

TET 8/PL

Lock with key type 405

TEL/PL

Key-operated Lock
Reinforced type

TER/PL

Lock with JIS key

TEL-JIS/PL

Lock with FAC key

TEL-FAC/PL

Manual lock

TEM/PL

Handle without lock

TE/PL

Padlocking device

BCME/PL

Handle for PLM-108

TEM/PL

3/47

03_040_050_EN.indd 47

2/4/08 12:50:21

POLYMEL

Mounting accessories

Mounting plates
A complete range of mounting plates comprised of 4 versions able to
provide all the mountings required for this installation system.
c Metal plates of galvanised sheet steel.
c Microperforated plates made of galvanised sheet steel with 3.6 mm
holes, 12.5 mm apart.
c Universal perforated plates for fast fixing of equipment, made of zinc steel.
c Insulating bakelite or polyester plates.

Metal

Microperforated
Metal

Perforated

Universal

12,5

12,5

10,5

25

8,5

12,5

25

12,5

20 25

12,5

3,6
A-75

A-75

6,5

Universal perforated

Polyester

P
10,5

Bakelite
15

25

12,5

12,5

B-75

B-75

Bakelite

Polyester
Insulated

For attachment
to enclosures

Metal

Perforated
Bakelite

Height
(A)
310

Width
(B)

215

265

150

Reference
MM-32

Thickness Weight
(mm)
(kg)
2

0.6

Reference
MB-32

Thickness Weight
(mm)
(kg)
4

Universal

Polyester

0.2

Reference
MP-32

Thickness Weight
(mm)
(kg)
4

0.3

Reference
MF-32

Thickness Weight
(mm)
(kg)
2

0.3

Reference
MR-32

255

154

308

255

265

200

MM-3025

0.6

MB-3025

0.3

MP-3025

0.4

MF-3025

0.5

MR-3025

253

228

430

330

365

250

MM-43

1.6

MB-43

0.5

MP-43

0.7

MF-43

1.5

MR-43

348

251

530

430

465

350

MM-54

2.5

MB-54

0.9

MP-54

1.2

MF-54

2.4

MR-54

450

351

647

435

565

350

MM-64

3.1

MB-64

1.1

MP-64

1.4

MF-64

MR-64

555

351

747

536

665

450

MM-75

4.6

MB-75

1.7

MP-75

2.1

MF-75

4.3

MR-75

645

451

847

636

765

550

MM-86

2.5

9.9

MB-86

2.3

MP-86

3.8

MF-86

2.5

MR-86

750

551

1056

812

965

750

MM-108

2.5

16.9

MB-108

5.7

MP-108

6.5

MF-108

2.5

16

MR-108

945

751

3/48

03_040_050_EN.indd 48

2/4/08 12:50:26

POLYMEL

Mounting accessories

Adjustable plate support


Supports designed to fit 200, 250, 300 and 350 mm deep enclosures.
With positioning notches along its entire length for depth adjustment of the
mounting plate every 12.5 mm.
c Made of galvanised sheet steel.
c Quick fixing to the enclosure.

Reference

PLM-43 and 54

DPLM-200

156

94

PLM-64

DPLM-250

200

100

PLM-75 and 86

DPLM-300N

250

100

PLM-108

DPLM-350

306

106

For attachment to enclosures

Fixing accessories for universal plates


Fixing nut

Fixing screw with washer

Thread type

Length
(mm)

Packaging

M3

TFP 3

100

M4

TFP 4

100

M5

TFP 5

100

M6

TFP 6

100

Packaging

TOR 10/4 A

10

100

TOR 16/4 A

16

100

TOR 12/5 A

12

100

TOR 18/5 A

18

100

TOR 12/6 A

12

100

TOR 18/6 A

18

100

15 15

1126 mm

30

30

3/49

03_040_050_EN.indd 49

2/4/08 12:50:27

POLYMEL

Mounting accessories

Rail fixing set


c Insulating support and self-tapping screw for quick fixing of L brackets and
35 mm symmetrical rails (Ref. TCO/PLM).
c Insulating support and M6 inserted bolt for quick fixing of L brackets and
35 mm symmetrical rails (Ref. TCO-M6/PLM).
Reference

Type of screw

TCO/PLM

Self-tapping

TCO-M6/PLM

M6

25

TCO/PLM

35 mm symmetrical rail
35 mm symmetrical rails to support equipment, specially adapted to the width of
the enclosures.
Fixing at the back of the enclosure using the TCO/PLM set.
For attachment to enclosures

Reference

Width

PLM-32

CO-200/PLM

180

PLM-43

CO-300/PLM

280

PLM-54 and 64

CO-400/PLM

380

PLM-75

CO-500/PLM

480

PLM-86

CO-600/PLM

580

PLM-108

CO-800/PLM

795

3/50

03_040_050_EN.indd 50

2/4/08 12:50:29

POLYMEL

Current distribution accessories

GCR ties
Clip in fasteners to be installed directly on 19 racks and on slotted MR
mounting plates.
Reference: GCR.

Adjustable ties
Made of 6.6 nylon in natural colour or black for outdoor conditions.
Reference

Use
L

minimum

maximum

White

Black

LZ25100

LN25100

100

2.5

1.6

22

LZ25200

LN25200

200

2.5

1.6

49

LZ35150

LN35150

150

3.5

1.6

35

LZ35200

LN35200

200

3.5

1.6

49

LZ35300

LN35300

300

3.5

1.6

75

LZ46150

LN46150

150

4.6

1.6

36

LZ46200

LN46200

200

4.6

1.6

49

LZ48270

LN48270

270

4.8

1.6

73

LZ46390

LN46390

390

4.6

1.6

109

LZ76390

LN76390

390

7.6

4.7

108

Tightening tools
To tighten and cut to size the adjustable ties. They facilitate wiring and save
time, preventing the packets of cables from loosening.
Tool adjustable according to the thickness of the tie. Can be used with the
following models: LZ25100 up to LZ46390. Ref.: MARK3.
A very light and ergonomic tool, the cut on the tie is done by twisting the
tool. Can be used on the following models of ties: LZ25100 up to LZ46390.
Ref.: MARK20, 21.
Reference
MARK3

Admissible width ties


2.5 4.8

Reference

Admissible width ties

MARK20

2.5 4.8

MARK21

4.6 7.6

3/51

03_051_062_EN.indd 51

2/4/08 12:51:54

POLYMEL

Current distribution accessories

Locking clips
Allows fixing ties from the series LZ25100 up to LZ46390 on panels up to
3.2 mm thick. Material: 6.6 nylon.
Perforation
mm

Max. panel
thickness mm

SFC1

3.2

SFC2

Reference

SFC2

SFC1

Fig. 1

Figure

Fig. 2

Stud
To use with soft materials: 7 mm hole, or hard materials: 8 mm hole.
Ties are attached up to 9 mm width. Material: black 6.6 nylon.
Ref.: LOK01.

Tie fixing support


To attach one or two ties, mounted with a single screw. Material: 6.6 nylon.
Allows for attaching ties from the entire range.
Reference

Fixing screw

Admissible width
ties

KR6

12

18

M4

2.5 4.8

KR8

14.5

25

12

M6

2.5 7.6

3/52

03_051_062_EN.indd 52

2/4/08 12:51:55

POLYMEL

Current distribution accessories

Support heads
To transform normal ties into ties with fixing heads, introduce a tie into this
head before closing it on the cable bundle. Material: 6.6 nylon.

Reference

Fixing screw

Admissible width
ties

FH18

7.1

13.3

M4

2.5

FH30

9.5

17.9

4.7

M5

3.5

FH50

11.3

22.2

6.2

M6

4.7

Self-adhesive support base


Permits insertion of 1 tie from 4 points at a 90 angle. Attaches ties from the
series LZ25100 up to LZ46390. Material: 6.6 nylon.
E

Admissible width
ties

3.2

13.2

2.5 3.5

20.2

2.5 4.8

MB3A

19.1

19.1

4.8

MB4A

28.5

28.5

5.5

Reference

adhesive support

Tie fixing support


To attach ties from any series. Material: 6.6 nylon.
Reference
LKC

Admissible width
ties mm
2.5 7.6

Fixing screw
M5

3/53

03_051_062_EN.indd 53

2/4/08 12:51:57

POLYMEL

Current distribution accessories

Lateral tie fixing support


Covers the head of the tie in its end, thus obtaining neater cabling.
Material: 6.6 nylon.
Reference

Admissible width
ties mm

LKM/HE

2.5 7.6

Fixing screw
M5

Fixing loop for tubes, hoses, etc.


2 versions, fixed and graduated, from 5 to 25.4 mm. Material: black 6.6 nylon.
Reference

3.5

6.2

13.7

NX3

3.9

9.4

20.5

NX5

12

3.9

9.4

24

NX8*

14.3 15.8

1.3

12.6

32

NX1

min. - max.

NX11

17.4 20

NX14

22.2 25.4

1.3

12.6

37

4.3

1.5

16

45

*The NX8 model only has 3 adjustment holes.

NX 1-3-5

NX 8-11-14

3/54

03_051_062_EN.indd 54

2/4/08 12:51:58

POLYMEL

Current distribution accessories

Adjustable membrane glands


Insulating membrane glands made of PVC with entry that can be adjusted
for cables.

Fig. 1

Fig. 2

Capacity
Reference

Fig.

B*

F
cable

Tube

ECPC-3

25

21.5

18

3.2

13

5 to 18

Pg 9 to 11

ECPC-5

33

29.5

26

3.2

20

5 to 26

Pg 9 to 16

ECPC-6

43

38.5

36

3.2

22

5 to 36

Pg 9 to 21

ECPC-9

70

63

60

28

20

28 to 60

Pg 21 to 48

ECPC-15

98

90

87

28

23

28 to 87

Pg 21 to 48

* Mounting perforation.

Protective sleeves
Small protective sleeves for cables coming out of tubes, as indicated in the
instructions for MI BT 019. Made of flexible and durable PVC, in light grey
colour.
A

PC-1

15.2

12.7

PC-2

18.6

16

Pg 11

PC-3

20.4

17.8

Pg 13.5

PC-4

22.5

19.8

Pg 16

PC-5

28.3

25.3

Pg 21

PC-6

37

33.6

Pg 29

PC-7

47

43

Pg 36

Tube
Pg 9

Reference

3/55

03_051_062_EN.indd 55

2/4/08 12:51:59

POLYMEL

Current distribution accessories

Useful information about Pg tubes and HIMEL accessories to be coupled


MODELS, DIMENSIONS AND REFERENCES
Tubes

HIMEL accessories to be coupled

interior
Designation

exterior

Steel
Flexible
steel

PVC

perforations
to

Cables inserted*
Flexible
steel with
PVC

11.1

No. of conductors
2

Insert

Thread

4
Pg 9

15.2

12.7

12.4

12

To the perforations

To the tubes

Adjustable
Protective membrane
Adjustable
sleeves
membrane glands
glands

Plain plugs

EC-1 to EC-7
2.5

16

14

ECPC-3 to ECPC-6

PC-1

PC-2

EC-2

ECN-5 to ECN-10
Pg 11

18.6

16

15.5

14.5

10

2.5

14.2

16

EC-2 to EC-7
4

2.5

19

17.5

25

ECPC-5; ECPC-6

EC-1

ECN-5 to ECN-10
EC-3 to EC-7

Pg 13.5

20.4

17.8

17.5

16.3

16

35

10

21

19.5

ECPC-5; ECPC-6

TC-1

ECN-1
EC-3
PC-3

ECPC-3

TC-2

PC-4

EC-4

TC-3

PC-5

ECPC-5

ECN-5 to ECN-10
EC-4 to EC-7
Pg 16

22.5

19.8

18.7

18.5

17.6

50

16

10

23

21.5

ECPC-5; ECPC-6
ECN-5 to ECN-10
EC-5 to EC-7

Pg 21

28.3

25.3

24.7

23

23

70

25

16

10

29

27

ECPC-6 to ECPC-15

EC-5

ECN-6 to ECN-10
Pg 29

37

33.6

33.5

31

31

95

35

25

16

120

50

35

25

EC-6; EC-7
38

35.5

150
47

43

41.5

41

40.3

240

35
70

50

50

48

45.5

Pg 48

54
60

50
56

48
54.2

48
52.5

47
51.4

ECPC-9; ECPC-15

EC-6

TC-5

ECPC-6

TCP-5

ECN-6

EC-7

300
Pg 42

PC-6

ECN-7; ECN-10

185
Pg 36

ECPC-9; ECPC-15

TC-4

ECN-5

EC-7
PC-7

ECN-7

TC-6

ECN-10
95

70

120

95

70

120

95

150

120

150

ECPC-9; ECPC-15
55

52.5

ECN-10

ECPC-9; ECPC-15
61

58

ECN-10

* Number and section in mm2 of the conductors that may be housed inside each tube (orientative).
For more information, consult the electrotechnical rules for low voltage (MI BT 019).

3/56

03_051_062_EN.indd 56

2/4/08 12:52:00

POLYMEL

Current distribution accessories

Sigma safety terminals


Base of safety terminals made of black matte self-extinguishing polyamide-6;
terminal of brass MS-58.
(DIN17660); ring of tempered steel zinc dichromate; cap made of orange
self-extinguishing polypropylene.
c Anti-cut. The connection is made using a tightening mechanism that
spreads the pressure out throughout the entire contact surface, avoiding
the occasional rubs and stresses that damage the conductors.
c Loosening proof. The ring that surrounds the brass body ensures that the
pressure exerted by the conductors cannot open the terminal and loosen
the connection.
c Total insulation. All the SIGMA terminals are supplied with a terminal cap,
avoiding any accidental contact with live parts.
All the calibres may be coupled one to the other, allowing the formation of
strips of any length. Service voltage: 500 V.

Section
m/m2

Reference

S.04

14

30

20

13

21

S.06

16

33

25

16

24

S.10

1 10

38

28

16

28

S.16

1 16

42

32

19

32

S.25/35

1 35

46

38

23

34

11

S.50

1 50

52

45

27

40

15

S.70

1 70

55

50

30

40

15

S.95/100

1 100

58

54

33

40

20

NOTE: each terminal accepts up to 2 conductors of the section indicated.

Bypass terminal blocks


Earth and neutral bypass terminal blocks with insulated plinth.
Direct fixing by pressure on the profile supplied by the chassis itself.
Reference

Number of terminals section in mm2

RBLZ/21656*

216 mm2 + 56 mm2

RBLZ/21686

216 mm2 + 86 mm2

RBLZ/216146

216 mm2 + 146 mm2

RBLZ/216296

216 mm2 + 296 mm2

* Included in standard supply.

3/57

03_051_062_EN.indd 57

2/4/08 12:52:00

POLYMEL

Current distribution accessories

Bimetal BBH terminals


BBH-29

Terminals especially designed for branching cables on plates; their main


application is busbar connection.

BBH-29D

BBH terminals are made of a tinned, hot cast copper alloy and are suitable
for connecting to a conductor of copper or aluminium indistinctly (bimetal).

Main section mm2

Bypass section mm2

BBH-29

6-50

BBH-29C*

6-50

BBH-30

10-95

BBH-31

16-150

BBH-32

50-240

6-50

6-50

Reference

BBH-29D

BBH-29P

BBH-29DP

BBH-29DC*

6-50

6-50

BBH-30D

10-95

10-95

BBH-31D

25-150

16-150

BBH-32D

95-240

5-240

Reference

Main section mm2

Bypass section mm2

BBH-29P

6-50

BBH-29PC*

6-50

BBH-29DP

6-50

6-50

BBH-29DPC*

6-50

6-50

* Include terminal cover CBBH-29.

Plate/cable terminals
Plate entry and bypass by cable.
Cable bypass section
(mm2)

Plate thickness (mm)

Figure

BPCH 516

1.5 to 16

BPCH 550

1.5 to 50

Reference

BPCH 5120

BPCH 1016

1.5 to 16

10

BPCH 1050

1.5 to 50

10

10

BPCH 10120

16 to 120

16 to 120

3/58

03_051_062_EN.indd 58

2/4/08 12:52:04

POLYMEL

Lighting accessories

Compact lamp
Compact fluorescent lamps, designed especially for use in electronic
enclosures. May be fixed with a magnet.
c Connection voltage 220 V/50 Hz.
c Consumption 11 W.
c Connection/disconnection switch.

70

c 200 V/16 A socket with earthing.

355

c Maximum ambient temperature 60 C.


c Lighting output = 75 W bulb.

90
66

Specifications

Reference

Plug

Tension

LAM-75

220 V/16 A

220 V/50 Hz

LAC-75

220 V/16 A

220 V/50 Hz

LAM-75/120

120 V/15 A

120 V/60 Hz

LAC-75/120

120 V/15 A

120 V/60 Hz

Lamp fixed with a magnet or


on 35 mm symmetric
DIN rail.
Lamp fixed on a 35 mm
symmetric DIN rail.
Lamp fixed with a magnet
or on 35 mm symmetric
DIN rail.
Lamp fixed on a 35 mm
symmetric DIN rail.

Slimline lamp
Magnetic-fixing flat lamps equipped with energy efficient light bulbs, with or
without a plug.
c Electronic ballast.
c Power: 11 W.
c Luminosity: 900 lm.
c Lifespan: 10000 h.
c Plastic casing UL94 V0.
c IP20.
c Class I.
Reference

Plug

Socket

Approval

LAMS75

AC 230 V/16 A

SCHUKO

VDE

LAMX75

AC 230 V/-

VDE

LAMU75

AC 120 V/15 A

USA

UL

3/59

03_051_062_EN.indd 59

2/4/08 12:52:06

POLYMEL

Lighting accessories

Incandescent lamp
Incandescent lamp designed especially for use in electronic enclosures.
c Connection voltage 220 V/50-60 Hz.
c Consumption 60 W.
500

c Connection/disconnection switch.
c Terminal connection entry.

Reference
LAI/OL 68

Dual lamp
1

Light fixtures designed especially for use in electronic enclosures with various
possibilities for fixing and operating.
c Energy efficient electronic lamp E27, 20 W, 220-240 V/50-60 Hz or
120 V/60 Hz.
c Lighting output = 100 W bulb.
c Fixed models connection via 2.5 mm2 terminal strip and the mobile model
via cable.

c Degree of protection IP20.


c Insulation class II.
c Conforming to EN 55014 and EN 50082-1.
Specifications
Motion-activated

Support fixing

Figure

Magnetic, using screws

and/or (1) 35 DIN rail

On/off switch with the possibility

Magnetic, using screws

of connection of door switch

and/or (1) 35 DIN rail

Mobile lamp, connection


via cable
Support for LAMDP, LAMIN,
LAMPO lamp

Adhesive or screws

Adhesive or screws

Reference
LAMDP

Tension
220 V/56 Hz

LAMDP 120

120 V/60 Hz

LAMIN

220 V/50 Hz

LAMIN 120

120 V/60 H

LAMPO

220 V/50 Hz

LAMPO 120

120 V/60 Hz

SOLAM

(1) DIN rail not provided.

100

67

396

3/60

03_051_062_EN.indd 60

2/4/08 12:52:07

POLYMEL

Natural ventilation accessories

Ventilation devices
To connect the inside of the enclosure with the exterior atmosphere and
prevent condensation. Can be fixed onto the outside, Ref.: VM-25
and VM-27 or onto the internal sides connected with the rear self-ventilating
windows of the POLYMEL enclosures, Ref.: VM-35.
Reference

Specifications

VM-25

For coupling to the outside of all polyester enclosures

VM-27
VM-35

VM-25

For coupling to the interior of POLYMEL enclosures

VM-27

VM-35

Purging device
To remove condensation water.
Mounted on the 9 mm housing on the inside of the bottom of the enclosure.
Degree of protection IP55.
Reference

Specifications

VEA-9

For attachment to all enclosures

Rear blanking plates


Rear blanking plates in insulating material to protect against unwanted
elements entering into the self-ventilating window of the enclosure.
Not included in standard supply with the enclosure except for model 108
which has it built in.

For attachment to enclosures

Reference

PLM-32

CE-PLM/A

PLM-43 and 54

CE-PLM/B

PLM-64, 75 and 86

CE-PLM/C

3/61

03_051_062_EN.indd 61

2/4/08 12:52:09

POLYMEL

Complementary accessories

Expandable nuts
Dodge-type brass nuts designed to be incorporated into the bosses of PLM
enclosures.
Specifications

TEX 8

TEX 6

For attachment to enclosures

Reference

M5

PLM-43 and 54

TEX 5

M6

PLM-64 and 108

TEX 6

M8

For the back of the enclosure

TEX 8

TEX 5

Document pocket
PP-A models made of thermo-plastic in grey RAL-7035.
c Fixed with adhesive tape or screws.
For holding A4 or A5-sized plans.
Insulated
Reference

A4

PP-A4

A5

PP-A5

174

234

Plan size

188
Ref.: PP-A5

22

278

40

Ref.: PP-A4

3/62

03_051_062_EN.indd 62

2/4/08 12:52:10

POLYMEL

Applications

Dinimel DLA distribution chassis

PLM-64/KT + DLA-48P

Distribution chassis set for modular


equipment, Ref.: DLA-... with a distance
between the 35 mm symmetric profile
and the cover, which is adjustable as
needed by the customer from 40 to
85 mm.

c Rigid structure made of galvanised steel.


c Insulating cover and frame in self-extinguishing material in RAL-7035.
Quick mounting, without the need for screws.
c System for identifying circuits included in the standard supply.
c Earth and neutral bypass terminal blocks. Ref.: RBLZ/21656 (included in
standard supply).

3/63

03_063_067_EN.indd 63

2/4/08 12:52:59

POLYMEL

Applications

Dimensions (mm)

* Models DLA-48P, 66, 88, 84 and 112.

DLA-24

DLA-48

DLA-48P

DLA-84
To be coupled
to enclosures*

DLA-240

Distribution of rows

Dimensions

Automatic rail
No. of rows

Transparent door

DLA-88

DLA-112

Reference
Plain door

DLA-66

Quantity

No. of 18 mm
modules

No. of plates

PLM-3025

PLM-3025/KT

DL/PLM18

18

PLM-43

PLM-43/KT

DLA-24

24

216

PLM-54

PLM-54/KT

DLA-48

48

288

PLM-64

PLM-64/KT

DLA-48P

48

288

PLM-75

PLM-75/KT

DLA-66

66

395

PLM-75

PLM-75/KT

DLA-88

88

395

PLM-86

PLM-86/KT

DLA-84

84

PLM-86

PLM-86/KT

DLA-112

112

PLM-108

PLM-108/KT

DLA-240

234

C
-

E min.

137

38

88

90

112

38

88

140

170

80

130

115

145

129

179

115

145

129

179

504

165

195

129

179

504

165

195

129

179

704

115

146

170

220

115

D min.

* For PLM.../CME enclosures with three-point locks, factory assembly

3/64

03_063_067_EN.indd 64

2/4/08 12:53:00

POLYMEL

Applications

Plain Dinimel DLA cover


Insulating cover in self-extinguishing material in RAL-7035 to protect nonmodular equipment. Height: 150 mm (1 row).
To be coupled to chassis

Reference

Reference

DLA-24

CTL300/DLA

256

DLA-48 and 48P

CTL400/DLA

356

DLA-66 and 88

CTL500/DLA

456

DLA-84 and 112

CTL600/DLA

555

DLA-240

CTL800/DLA

755

Dinimel DLA mounting plate


Mounting plate in galvanised steel for fixing non-modular equipment. Height:
150 mm (1 row).
To be coupled to chassis

Reference

Width

DLA-24

PMP300/DLA

215

DLA-48 and 48P

PMP400/DLA

315

DLA-66 and 88

PMP500/DLA

415

DLA-84 and 112

PMP600/DLA

514

DLA-240

PMP800/DLA

714

Blanking plate
Blanking plate of self-extinguishing insulating material for total or partial
coverage of the windows for automatic switches. Easily cut to the desired
size.
Reference

Length (mm)

No. of modules

ATP6/DTM

108

ATP24/DTM

432

24

1100

Cut to size

ATP/UND

3/65

03_063_067_EN.indd 65

2/4/08 12:53:01

POLYMEL

Applications

Bypass terminal blocks


Earth and neutral bypass terminal blocks with insulating plinth.
Direct fixing by pressure on the profile supplied by the chassis itself.
Reference

Number of terminals 3 section in mm2

RBLZ/21656*

216 mm2 + 56 mm2

RBLZ/21686

216 mm2 + 86 mm2

RBLZ/216146

216 mm2 + 146 mm2

RBLZ/216296

216 mm2 + 296 mm2

* Included in standard supply.

Distribution bars
For the distribution in a single row of automatic switches with a total of 12
modules.
1

2
No. of poles per bar

Reference

12

BDS 1/12

BDS 2/6

BDS 3/4

BDS 4/3

No. of bars

Figure No.

3/66

03_063_067_EN.indd 66

2/4/08 12:53:01

POLYMEL

Applications

POLYMEL enclosures in exterior industrial installations


Due to the quality of the plastic materials and their constructive
characteristics, POLYMEL enclosures are suitable for panels in installations
subjected to contact with chemical agents and harsh environments, usually,
for example, in the petrochemical, cement making, etc. industries.

POLYMEL enclosures in interior industrial installations


Their high degree of protection (IP66) and their high resistance to impacts
and temperature make POLYMEL enclosures particularly ideal for industrial
installations subjected to processes with frequent water projection, such as
the paper-making and agri-food industries or automobile washes.

POLYMEL enclosures in leisure facilities


Their resistance to corrosion and UV rays permits POLYMEL enclosures to
be adapted to panels in exterior installations subjected to long exposures to
the sun: winter sport stations, installations close to the sea, etc.

3/67

03_063_067_EN.indd 67

2/4/08 12:53:05

PLA polyester modular enclosures

6 7
1

Wall fixing brackets.

Detail of fixing the


glass to the inside of the
door.

8 Detail of bosses on the


doors, back and lower part
of the enclosure for fixing of
various materials.

14

13

12 11 10 9

8
12 Mounting plate fixing
support, adjustable every
25 mm.

3/68

03_068_069.indd 68

22/2/08 18:35:30

2-point locking system


(up to 750 mm height) or
4-point locking system
(from 1,000 mm height).

6 Ribbed door to make


fixing of posters difficult.
Likewise, this uneven
surface makes the
door thicker and also
improves the robustness
of the enclosure.

7 The locking system is outside the sealed area,


which guarantees the IP over time. Handle lock with
detail of the cover that hides the lock device.

9 Anti-vandalism
reinforcement.

10

13

14 Metal, insulating or
universal mounting plates
to be fixed directly to the
back of the enclosure
or by using adjustable
supports.

PLAZ... enclosures
with open plinth-type
bottom for easy cable
entry.

The enclosures
with canopies allow
self-ventilation of the
enclosure, preventing
condensation and
maintaining the IP54.

Door opening to
180, which improves
accessibility to the interior
of the enclosure with
plinth and canopy. The
plinth-type base allows
direct floor fixing.

Detail of 120 hinge


with easily removable
stainless steel safety
pin. Seal that guarantees
IP65 watertightness.

11

Door retainer.

3/69

03_068_069.indd 69

22/2/08 18:35:32

CONSTRUCTION SYSTEMS
Table of formation references

Enclosures with closed base

Enclosures with open plinth-type base

Closed top

Self-ventilated top with


canopy

Closed top

Self-ventilated top with


canopy

General table with the construction systems on the horizontal axis


and the various versions of doors on the vertical axis, offering a
panoramic view of the formation of all the possibilities of references.

PLA...

PLA...T

PLAZ...

PLAZ...T

Door opening

120

120

120

180

Degree of protection

IP65

IP54

IP54

IP54

Plain door
PLA/PLAZ
...

PLA 1054

PLA 1054 T

PLAZ 1054

PLAZ 1054 T

Transparent door
PLA/PLAZ
...KT

PLA 1054 KT

PLA 1054 TKT

PLAZ 1054 KT

PLAZ 1054 TKT

Ribbed door
PLA/PLAZ
...R

PLA 1054 R

PLA 1054 TR

PLAZ 1054 R

PLAZ 1054 TR

Plain front and


back doors
PLA/PLAZ
...P

PLA 1054 P

PLA 1054 TP

PLAZ 1054 P

PLAZ 1054 TP

Transparent front door and


plain back door
PLA/PLAZ
...PKT

PLA 1054 PKT

PLA 1054 TPKT

PLAZ 1054 PKT

PLAZ 1054 TPKT

Ribbed front and back doors


PLA/PLAZ
...PR

PLA 1273 PR

PLA 1273 TPR

PLAZ 1273 PR

PLAZ 1273 TPR

EXAMPLES OF FORMING REFERENCES


Construction systems
With base
Closed

Examples of enclosures

Height: 1,000

Width: 500

Dimensions (mm)

Open, plinth-type

Height

Width

Depth

XX

XX

10

PLAZ

12

PLA

PLAZ

PLA

Depth: 420

Top and bottom closed, with transparent door.


Ref.: PLA 1054 KT
Height: 1,200

Width: 750

Depth: 320

Self-ventilated top with canopy, open plinth-type bottom, ribbed front


and back doors.
Ref.: PLA Z 1273 TPR

3/70

03_070_083_EN.indd 70

5/3/08 11:20:50

The table showing each of the dimensions (height, width and depth)
determines the digits to use when forming the references.
The tables in grey and blue have to do with to the examples of the
reference formation table.

Nominal dimensions (mm)


Height

Width

Depth

5 00

5 00

7 50

3 20

7 50

10 00

10 00

12 50

4 20

12 50

15 00

With top

Door version

Closed

Self-ventilated
with canopy

Plain

Transparent

Ribbed

KT

PR

KT

PR

Plain front cover and back Ribbed front cover and back

3/71

03_070_083_EN.indd 71

5/3/08 11:20:52

PLA...

PLA 1253

Hot-press moulded fibreglass-reinforced


polyester enclosures, in grey RAL-7032
(able to withstand weather conditions).

Polyester enclosures completely closed


IP65 (EN 60529)

PLA 12123

Construction specifications
c Resistance to the main chemical agents and corrosive environments.
c Stabilised against UV rays.
c Door reversibility with opening to 120, with max. admissible load of 30 kg/m2.
c Lock outside of the sealed area, with a 2-point locking system up to
750 mm height, 4-point locking system from 1000 mm height.
c Interior of the enclosure equipped with bosses for M8 inserts. They allow
direct fixing of mounting plates and/or the desired installation system,
accessories, etc.
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and
EN 62208.
c IP65 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20J) conforming to IEC and
EN 62262).
c Self-extinguishing, conforming to IEC 60695-2-1 (960).
c Extreme operating temperatures from 50 to +150 C.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.

3/72

03_070_083_EN.indd 72

5/3/08 11:20:53

Completely closed polyester enclosures


IP65 (EN 60529)

PLA...

Basic composition
c Enclosure with top and base completely closed.
c Sealing gasket.
c Plain, transparent or ribbed door.
c KT model: transparent door of tempered glass with a high resistance to
mechanical impacts IK08 (5J) conforming to EN 62262.
c ..R model: ribbed door to make fixing of posters difficult and with antilever hinges.
c Back panel or door.
c Reversible door with 2 hinges up to 750 mm height, and 4 from 1000 mm
height.
c Standard double bar lock, operated by key LDB5.
c Two-door enclosures have a central profile.

SELECTION TABLE FOR CLOSED POLYESTER ENCLOSURES

Nominal dimensions (mm)

Height

Width

Depth

500

500

320

PLA 553

PLA 553 R

PLA 553 KT

PLA 553 P

PLA 553 PR

PLA 553 PKT

420

PLA 554

PLA 554 R

PLA 554 KT

PLA 554 P

PLA 554 PR

PLA 554 PKT

320

PLA 573

PLA 573 R

PLA 573 KT

PLA 573 P

PLA 573 PR

PLA 573 PKT

420

PLA 574

PLA 574 R

PLA 574 KT

PLA 574 P

PLA 574 PR

PLA 574 PKT

320

PLA 5103

PLA 5103 R

PLA 5103 KT

PLA 5103 P

PLA 5103 PR

PLA 5103 PKT

420

PLA 5104

PLA 5104 R

PLA 5104 KT

PLA 5104 P

PLA 5104 PR

PLA 5104 PKT

320

PLA 5123

PLA 5123 R

PLA 5123 KT

PLA 5123 P

PLA 5123 PR

PLA 5123 PKT

420

PLA 5124

PLA 5124 R

PLA 5124 KT

PLA 5124 P

PLA 5124 PR

PLA 5124 PKT

320

PLA 753

PLA 753 R

PLA 753 KT

PLA 753 P

PLA 753 PR

PLA 753 PKT

420

PLA 754

PLA 754 R

PLA 754 KT

PLA 754 P

PLA 754 PR

PLA 754 PKT

320

PLA 773

PLA 773 R

PLA 773 KT

PLA 773 P

PLA 773 PR

PLA 773 PKT

420

PLA 774

PLA 774 R

PLA 774 KT

PLA 774 P

PLA 774 PR

PLA 774 PKT

320

PLA 7103

PLA 7103 R

PLA 7103 KT

PLA 7103 P

PLA 7103 PR

PLA 7103 PKT

420

PLA 7104

PLA 7104 R

PLA 7104 KT

PLA 7104 P

PLA 7104 PR

PLA 7104 PKT

320

PLA 7123

PLA 7123 R

PLA 7123 KT

PLA 7123 P

PLA 7123 PR

PLA 7123 PKT

420

PLA 7124

PLA 7124 R

PLA 7124 KT

PLA 7124 P

PLA 7124 PR

PLA 7124 PKT

320

PLA 1053

PLA 1053 R

PLA 1053 KT

PLA 1053 P

PLA 1053 PR

PLA 1053 PKT

420

PLA 1054

PLA 1054 R

PLA 1054 KT

PLA 1054 P

PLA 1054 PR

PLA 1054 PKT

320

PLA 1073

PLA 1073 R

PLA 1073 KT

PLA 1073 P

PLA 1073 PR

PLA 1073 PKT

420

PLA 1074

PLA 1074 R

PLA 1074 KT

PLA 1074 P

PLA 1074 PR

PLA 1074 PKT

320

PLA 10103

PLA 10103 R

PLA 10103 KT

PLA 10103 P

PLA 10103 PR

PLA 10103 PKT

420

PLA 10104

PLA 10104 R

PLA 10104 KT

PLA 10104 P

PLA 10104 PR

PLA 10104 PKT

320

PLA 10123

PLA 10123 R

PLA 10123 KT

PLA 10123 P

PLA 10123 PR

PLA 10123 PKT

420

PLA 10124

PLA 10124 R

PLA 10124 KT

PLA 10124 P

PLA 10124 PR

PLA 10124 PKT

320

PLA 1253

PLA 1253 R

PLA 1253 KT

PLA 1253 P

PLA 1253 PR

PLA 1253 PKT

420

PLA 1254

PLA 1254 R

PLA 1254 KT

PLA 1254 P

PLA 1254 PR

PLA 1254 PKT

320

PLA 1273

PLA 1273 R

PLA 1273 KT

PLA 1273 P

PLA 1273 PR

PLA 1273 PKT

420

PLA 1274

PLA 1274 R

PLA 1274 KT

PLA 1274 P

PLA 1274 PR

PLA 1274 PKT

320

PLA 12103

PLA 12103 R

PLA 12103 KT

PLA 12103 P

PLA 12103 PR

PLA 12103 PKT

420

PLA 12104

PLA 12104 R

PLA 12104 KT

PLA 12104 P

PLA 12104 PR

PLA 12104 PKT

320

PLA 12123

PLA 12123 R

PLA 12123 KT

PLA 12123 P

PLA 12123 PR

PLA 12123 PKT

420

PLA 12124

PLA 12124 R

PLA 12124 KT

PLA 12124 P

PLA 12124 PR

PLA 12124 PKT

320

PLA 1553

PLA 1553 R

PLA 1553 KT

PLA 1553 P

PLA 1553 PR

PLA 1553 PKT

420

PLA 1554

PLA 1554 R

PLA 1554 KT

PLA 1554 P

PLA 1554 PR

PLA 1554 PKT

320

PLA 1573

PLA 1573 R

PLA 1573 KT

PLA 1573 P

PLA 1573 PR

PLA 1573 PKT

420

PLA 1574

PLA 1574 R

PLA 1574 KT

PLA 1574 P

PLA 1574 PR

PLA 1574 PKT

320

PLA 15103

PLA 15103 R

PLA 15103 KT

PLA 15103 P

PLA 15103 PR

PLA 15103 PKT

420

PLA 15104

PLA 15104 R

PLA 15104 KT

PLA 15104 P

PLA 15104 PR

PLA 15104 PKT

320

PLA 15123

PLA 15123 R

PLA 15123 KT

PLA 15123 P

PLA 15123 PR

PLA 15123 PKT

420

PLA 15124

PLA 15124 R

PLA 15124 KT

PLA 15124 P

PLA 15124 PR

PLA 15124 PKT

750
1000
1250
750

500
750
1000
1250

1000

500
750
1000
1250

1250

500
750
1000
1250

1500

500
750
1000
1250

No. of doors

3/73

03_070_083_EN.indd 73

5/3/08 11:20:55

PLA...T

Polyester enclosures with self-ventilated top


with canopy and closed base
IP54 (EN 60529)

PLA 1253T

Hot-press moulded, fibreglass-reinforced,


self-ventilated polyester enclosures,
in grey RAL-7032 (able to withstand
weather conditions).

Construction specifications
c Resistance to the main chemical agents and corrosive environments.
c Stabilised against UV rays.
c Door reversibility with opening to 120, with max. admissible load of 30 kg/m2.
c Lock outside of the sealed area, with a 2-point locking system up to
750 mm height, 4-point locking system from 1000 mm height.
c Interior of the enclosure equipped with bosses for M8 inserts. They allow
direct fixing of mounting plates and/or the desired installation system,
accessories, etc.
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and
EN 62208.
c IP54 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20J) conforming to IEC and
EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960).
c Extreme operating temperatures from 50 to +150 C.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.

3/74

03_070_083_EN.indd 74

5/3/08 11:20:56

Polyester enclosures with self-ventilated top


with canopy and closed base
IP54 (EN 60529)

PLA...T

Basic composition
c Open top with canopy.
c Base completely closed.
c Sealing gasket.
c Plain, transparent or ribbed door.
c KT model: transparent door of tempered glass with a high resistance to
mechanical impacts IK08 (5J) conforming to IEC and EN 62262.
c ..R model: ribbed door to make fixing of posters difficult and with antilever hinges.
c Back panel or door.
c Reversible door with 2 hinges up to 750 mm height, and 4 from 1000 mm
height.
c Standard double bar handle lock, operated by key LDB5.
c Two-door enclosures have a central profile.

SELECTION TABLE FOR CLOSED BASE, SELF-VENTILATED POLYESTER ENCLOSURES

Nominal dimensions (mm)

Height
500

Width
500
750
1000
1250

750

500
750
1000
1250

1000

500
750
1000
1250

1250

500
750
1000
1250

1500

500
750
1000
1250

Depth

No. of doors

320

PLA 553 T

PLA 553 TR

PLA 553 TKT

PLA 553 TP

PLA 553 TPR

PLA 553 TPKT

420

PLA 554 T

PLA 554 TR

PLA 554 TKT

PLA 554 TP

PLA 554 TPR

PLA 554 TPKT

320

PLA 573 T

PLA 573 TR

PLA 573 TKT

PLA 573 TP

PLA 573 TPR

PLA 573 TPKT

420

PLA 574 T

PLA 574 TR

PLA 574 TKT

PLA 574 TP

PLA 574 TPR

PLA 574 TPKT

320

PLA 5103 T

PLA 5103 TR

PLA 5103 TKT

PLA 5103 TP

PLA 5103 TPR

PLA 5103 TPKT

420

PLA 5104 T

PLA 5104 TR

PLA 5104 TKT

PLA 5104 TP

PLA 5104 TPR

PLA 5104 TPKT

320

PLA 5123 T

PLA 5123 TR

PLA 5123 TKT

PLA 5123 TP

PLA 5123 TPR

PLA 5123 TPKT

420

PLA 5124 T

PLA 5124 TR

PLA 5124 TKT

PLA 5124 TP

PLA 5124 TPR

PLA 5124 TPKT

320

PLA 753 T

PLA 753 TR

PLA 753 TKT

PLA 753 TP

PLA 753 TPR

PLA 753 TPKT

420

PLA 754 T

PLA 754 TR

PLA 754 TKT

PLA 754 TP

PLA 754 TPR

PLA 754 TPKT

320

PLA 773 T

PLA 773 TR

PLA 773 TKT

PLA 773 TP

PLA 773 TPR

PLA 773 TPKT

420

PLA 774 T

PLA 774 TR

PLA 774 TKT

PLA 774 TP

PLA 774 TPR

PLA 774 TPKT

320

PLA 7103 T

PLA 7103 TR

PLA 7103 TKT

PLA 7103 TP

PLA 7103 TPR

PLA 7103 TPKT

420

PLA 7104 T

PLA 7104 TR

PLA 7104 TKT

PLA 7104 TP

PLA 7104 TPR

PLA 7104 TPKT

320

PLA 7123 T

PLA 7123 TR

PLA 7123 TKT

PLA 7123 TP

PLA 7123 TPR

PLA 7123 TPKT

420

PLA 7124 T

PLA 7124 TR

PLA 7124 TKT

PLA 7124 TP

PLA 7124 TPR

PLA 7124 TPKT

320

PLA 1053 T

PLA 1053 TR

PLA 1053 TKT

PLA 1053 TP

PLA 1053 TPR

PLA 1053 TPKT

420

PLA 1054 T

PLA 1054 TR

PLA 1054 TKT

PLA 1054 TP

PLA 1054 TPR

PLA 1054 TPKT

320

PLA 1073 T

PLA 1073 TR

PLA 1073 TKT

PLA 1073 TP

PLA 1073 TPR

PLA 1073 TPKT

420

PLA 1074 T

PLA 1074 TR

PLA 1074 TKT

PLA 1074 TP

PLA 1074 TPR

PLA 1074 TPKT

320

PLA 10103 T

PLA 10103 TR

PLA 10103 TKT

PLA 10103 TP

PLA 10103 TPR

PLA 10103 TPKT

420

PLA 10104 T

PLA 10104 TR

PLA 10104 TKT

PLA 10104 TP

PLA 10104 TPR

PLA 10104 TPKT

320

PLA 10123 T

PLA 10123 TR

PLA 10123 TKT

PLA 10123 TP

PLA 10123 TPR

PLA 10123 TPKT

420

PLA 10124 T

PLA 10124 TR

PLA 10124 TKT

PLA 10124 TP

PLA 10124 TPR

PLA 10124 TPKT

320

PLA 1253 T

PLA 1253 TR

PLA 1253 TKT

PLA 1253 TP

PLA 1253 TPR

PLA 1253 TPKT

420

PLA 1254 T

PLA 1254 TR

PLA 1254 TKT

PLA 1254 TP

PLA 1254 TPR

PLA 1254 TPKT

320

PLA 1273 T

PLA 1273 TR

PLA 1273 TKT

PLA 1273 TP

PLA 1273 TPR

PLA 1273 TPKT

420

PLA 1274 T

PLA 1274 TR

PLA 1274 TKT

PLA 1274 TP

PLA 1274 TPR

PLA 1274 TPKT

320

PLA 12103 T

PLA 12103 TR

PLA 12103 TKT

PLA 12103 TP

PLA 12103 TPR

PLA 12103 TPKT

420

PLA 12104 T

PLA 12104 TR

PLA 12104 TKT

PLA 12104 TP

PLA 12104 TPR

PLA 12104 TPKT

320

PLA 12123 T

PLA 12123 TR

PLA 12123 TKT

PLA 12123 TP

PLA 12123 TPR

PLA 12123 TPKT

420

PLA 12124 T

PLA 12124 TR

PLA 12124 TKT

PLA 12124 TP

PLA 12124 TPR

PLA 12124 TPKT

320

PLA 1553 T

PLA 1553 TR

PLA 1553 TKT

PLA 1553 TP

PLA 1553 TPR

PLA 1553 TPKT

420

PLA 1554 T

PLA 1554 TR

PLA 1554 TKT

PLA 1554 TP

PLA 1554 TPR

PLA 1554 TPKT

320

PLA 1573 T

PLA 1573 TR

PLA 1573 TKT

PLA 1573 TP

PLA 1573 TPR

PLA 1573 TPKT

420

PLA 1574 T

PLA 1574 TR

PLA 1574 TKT

PLA 1574 TP

PLA 1574 TPR

PLA 1574 TPKT

320

PLA 15103 T

PLA 15103 TR

PLA 15103 TKT

PLA 15103 TP

PLA 15103 TPR

PLA 15103 TPKT

420

PLA 15104 T

PLA 15104 TR

PLA 15104 TKT

PLA 15104 TP

PLA 15104 TPR

PLA 15104 TPKT

320

PLA 15123 T

PLA 15123 TR

PLA 15123 TKT

PLA 15123 TP

PLA 15123 TPR

PLA 15123 TPKT

420

PLA 15124 T

PLA 15124 TR

PLA 15124 TKT

PLA 15124 TP

PLA 15124 TPR

PLA 15124 TPKT

3/75

03_070_083_EN.indd 75

5/3/08 11:20:57

PLAZ...

Polyester enclosures with closed top and open


plinth-type base
IP54 (EN 60529)

PLAZ 1253

Hot-press moulded fibreglass-reinforced


polyester enclosures, in grey RAL-7032
(able to withstand weather conditions).

Construction specifications
c Resistance to the main chemical agents and corrosive environments.
c Stabilised against UV rays.
c Door reversibility with opening to 120, with max. admissible load of
30 kg/m2.
c Lock outside of the sealed area, with a 2-point locking system up to
750 mm height, 4-point locking system from 1000 mm height.
c Interior of the enclosure equipped with bosses for M8 inserts. They allow
direct fixing of mounting plates and/or the desired installation system,
accessories, etc.
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and
EN 62208.
c IP54 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20J) conforming to IEC and
EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960).
c Extreme operating temperatures from 50 to +150 C.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.

3/76

03_070_083_EN.indd 76

5/3/08 11:20:57

Polyester enclosures with closed top and open


plinth-type base
IP54 (EN 60529)

PLAZ...

Basic composition
c Closed top.
c Open plinth-type base.
c Sealing gasket.
c Plain, transparent or ribbed door.
c KT model: transparent door of tempered glass with a high resistance to
mechanical impacts IK08 (5J) conforming to IEC and EN 62262.
c ..R model: ribbed door to make fixing of posters difficult and with antilever hinges.
c Back panel or door.
c Reversible door with 2 hinges up to 750 mm height, and 4 from 1000 mm
height.
c Standard double bar handle lock, operated by key LDB5.
c Two-door enclosures have a central profile.
SELECTION TABLE FOR POLYESTER ENCLOSURES WITH CLOSED TOP AND OPEN PLINTH-TYPE BASE

Nominal dimensions (mm)

Height

Width

500

500

Depth

No. of doors

320

PLAZ 553

PLAZ 553 R

PLAZ 553 KT

PLAZ 553 P

PLAZ 553 PR

PLAZ 553 PKT

420

PLAZ 554

PLAZ 554 R

PLAZ 554 KT

PLAZ 554 P

PLAZ 554 PR

PLAZ 554 PKT

320

PLAZ 573

PLAZ 573 R

PLAZ 573 KT

PLAZ 573 P

PLAZ 573 PR

PLAZ 573 PKT

420

PLAZ 574

PLAZ 574 R

PLAZ 574 KT

PLAZ 574 P

PLAZ 574 PR

PLAZ 574 PKT

320

PLAZ 5103

PLAZ 5103 R

PLAZ 5103 KT

PLAZ 5103 P

PLAZ 5103 PR

PLAZ 5103 PKT

420

PLAZ 5104

PLAZ 5104 R

PLAZ 5104 KT

PLAZ 5104 P

PLAZ 5104 PR

PLAZ 5104 PKT

320

PLAZ 5123

PLAZ 5123 R

PLAZ 5123 KT

PLAZ 5123 P

PLAZ 5123 PR

PLAZ 5123 PKT

420

PLAZ 5124

PLAZ 5124 R

PLAZ 5124 KT

PLAZ 5124 P

PLAZ 5124 PR

PLAZ 5124 PKT

500

320

PLAZ 753

PLAZ 753 R

PLAZ 753 KT

PLAZ 753 P

PLAZ 753 PR

PLAZ 753 PKT

420

PLAZ 754

PLAZ 754 R

PLAZ 754 KT

PLAZ 754 P

PLAZ 754 PR

PLAZ 754 PKT

750

320

PLAZ 773

PLAZ 773 R

PLAZ 773 KT

PLAZ 773 P

PLAZ 773 PR

PLAZ 773 PKT

420

PLAZ 774

PLAZ 774 R

PLAZ 774 KT

PLAZ 774 P

PLAZ 774 PR

PLAZ 774 PKT

320

PLAZ 7103

PLAZ 7103 R

PLAZ 7103 KT

PLAZ 7103 P

PLAZ 7103 PR

PLAZ 7103 PKT

420

PLAZ 7104

PLAZ 7104 R

PLAZ 7104 KT

PLAZ 7104 P

PLAZ 7104 PR

PLAZ 7104 PKT

320

PLAZ 7123

PLAZ 7123 R

PLAZ 7123 KT

PLAZ 7123 P

PLAZ 7123 PR

PLAZ 7123 PKT

420

PLAZ 7124

PLAZ 7124 R

PLAZ 7124 KT

PLAZ 7124 P

PLAZ 7124 PR

PLAZ 7124 PKT

320

PLAZ 1053

PLAZ 1053 R

PLAZ 1053 KT

PLAZ 1053 P

PLAZ 1053 PR

PLAZ 1053 PKT

420

PLAZ 1054

PLAZ 1054 R

PLAZ 1054 KT

PLAZ 1054 P

PLAZ 1054 PR

PLAZ 1054 PKT

320

PLAZ 1073

PLAZ 1073 R

PLAZ 1073 KT

PLAZ 1073 P

PLAZ 1073 PR

PLAZ 1073 PKT

420

PLAZ 1074

PLAZ 1074 R

PLAZ 1074 KT

PLAZ 1074 P

PLAZ 1074 PR

PLAZ 1074 PKT

1000

320

PLAZ 10103

PLAZ 10103 R

PLAZ 10103 KT

PLAZ 10103 P

PLAZ 10103 PR

PLAZ 10103 PKT

420

PLAZ 10104

PLAZ 10104 R

PLAZ 10104 KT

PLAZ 10104 P

PLAZ 10104 PR

PLAZ 10104 PKT

1250

320

PLAZ 10123

PLAZ 10123 R

PLAZ 10123 KT

PLAZ 10123 P

PLAZ 10123 PR

PLAZ 10123 PKT

420

PLAZ 10124

PLAZ 10124 R

PLAZ 10124 KT

PLAZ 10124 P

PLAZ 10124 PR

PLAZ 10124 PKT

320

PLAZ 1253

PLAZ 1253 R

PLAZ 1253 KT

PLAZ 1253 P

PLAZ 1253 PR

PLAZ 1253 PKT

420

PLAZ 1254

PLAZ 1254 R

PLAZ 1254 KT

PLAZ 1254 P

PLAZ 1254 PR

PLAZ 1254 PKT

320

PLAZ 1273

PLAZ 1273 R

PLAZ 1273 KT

PLAZ 1273 P

PLAZ 1273 PR

PLAZ 1273 PKT

420

PLAZ 1274

PLAZ 1274 R

PLAZ 1274 KT

PLAZ 1274 P

PLAZ 1274 PR

PLAZ 1274 PKT

320

PLAZ 12103

PLAZ 12103 R

PLAZ 12103 KT

PLAZ 12103 P

PLAZ 12103 PR

PLAZ 12103 PKT

420

PLAZ 12104

PLAZ 12104 R

PLAZ 12104 KT

PLAZ 12104 P

PLAZ 12104 PR

PLAZ 12104 PKT

320

PLAZ 12123

PLAZ 12123 R

PLAZ 12123 KT

PLAZ 12123 P

PLAZ 12123 PR

PLAZ 12123 PKT

420

PLAZ 12124

PLAZ 12124 R

PLAZ 12124 KT

PLAZ 12124 P

PLAZ 12124 PR

PLAZ 12124 PKT

320

PLAZ 1553

PLAZ 1553 R

PLAZ 1553 KT

PLAZ 1553 P

PLAZ 1553 PR

PLAZ 1553 PKT

420

PLAZ 1554

PLAZ 1554 R

PLAZ 1554 KT

PLAZ 1554 P

PLAZ 1554 PR

PLAZ 1554 PKT

320

PLAZ 1573

PLAZ 1573 R

PLAZ 1573 KT

PLAZ 1573 P

PLAZ 1573 PR

PLAZ 1573 PKT

420

PLAZ 1574

PLAZ 1574 R

PLAZ 1574 KT

PLAZ 1574 P

PLAZ 1574 PR

PLAZ 1574 PKT

1000

320

PLAZ 15103

PLAZ 15103 R

PLAZ 15103 KT

PLAZ 15103 P

PLAZ 15103 PR

PLAZ 15103 PKT

420

PLAZ 15104

PLAZ 15104 R

PLAZ 15104 KT

PLAZ 15104 P

PLAZ 15104 PR

PLAZ 15104 PKT

1250

320

PLAZ 15123

PLAZ 15123 R

PLAZ 15123 KT

PLAZ 15123 P

PLAZ 15123 PR

PLAZ 15123 PKT

420

PLAZ 15124

PLAZ 15124 R

PLAZ 15124 KT

PLAZ 15124 P

PLAZ 15124 PR

PLAZ 15124 PKT

750
1000
1250
750

1000
1250
1000

500
750

1250

500
750
1000
1250

1500

500
750

3/77

03_070_083_EN.indd 77

5/3/08 11:20:58

Polyester enclosures with self-ventilated top


with canopy and open plinth-type base
IP54 (EN 60529)

PLAZ...T

PLAZ 7103T

Hot-press moulded, fibreglass-reinforced,


self-ventilated polyester enclosures,
in grey RAL-7032 (able to withstand
weather conditions).

Construction specifications
c Resistance to the main chemical agents and corrosive environments.
c Stabilised against UV rays.
c Door reversibility with opening to 180, with max. admissible load of 30 kg/m2.
c Lock outside of the sealed area, with a 2-point locking system up to
750 mm height, 4-point locking system from 1000 mm height.
c Interior of the enclosure equipped with bosses for M8 inserts. They allow
direct fixing of mounting plates and/or the desired installation system,
accessories, etc.
Technical specifications
c Conforms to general rules for empty enclosures established in IEC and
EN 62208.
c IP54 conforming to IEC 60529 (EN 60529).
c High resistance to mechanical impacts IK10 (20 J) conforming to IEC and
EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960).
c Extreme operating temperatures from 50 to +150 C.
c Suitable for double insulation profiles conforming to IEC 60439-1 (EN 60439-1).
c Resistant to corrosion.

3/78

03_070_083_EN.indd 78

5/3/08 11:20:59

Polyester enclosures with self-ventilated


top with canopy and open plinth-type base
IP54 (EN 60529)

PLAZ...T

Basic composition
c Open top with canopies.
c Open plinth-type base.
c Sealing gasket.
c Plain, transparent or ribbed door.
c KT model: transparent door of tempered glass with a high resistance to
mechanical impacts IK08 (5J) conforming to EN 50102.
c ..R model: ribbed door to make fixing of posters difficult and with antilever hinges.
c Back panel or door.
c Reversible door with 2 hinges up to 750 mm height, and 4 from 1000 mm
height.
c Standard double bar handle lock, operated by key LDB5.
c Two-door enclosures have a central profile.
SELECTION TABLE FOR POLYESTER ENCLOSURES WITH SELF-VENTILATED TOP WITH CANOPY AND OPEN PLINTH-TYPE BASE

Nominal dimensions (mm)

Height
500

Width
500
750
1000
1250

750

500
750
1000
1250

1000

500
750
1000
1250

1250

500
750
1000
1250

1500

500
750
1000
1250

Depth

No. of doors

320

PLAZ 553 T

PLAZ 553 TR

PLAZ 553 TKT

PLAZ 553 TP

PLAZ 553 TPR

PLAZ 553 TPKT

420

PLAZ 554 T

PLAZ 554 TR

PLAZ 554 TKT

PLAZ 554 TP

PLAZ 554 TPR

PLAZ 554 TPKT

320

PLAZ 573 T

PLAZ 573 TR

PLAZ 573 TKT

PLAZ 573 TP

PLAZ 573 TPR

PLAZ 573 TPKT

420

PLAZ 574 T

PLAZ 574 TR

PLAZ 574 TKT

PLAZ 574 TP

PLAZ 574 TPR

PLAZ 574 TPKT

320

PLAZ 5103 T

PLAZ 5103 TR

PLAZ 5103 TKT

PLAZ 5103 TP

PLAZ 5103 TPR

PLAZ 5103 TPKT

420

PLAZ 5104 T

PLAZ 5104 TR

PLAZ 5104 TKT

PLAZ 5104 TP

PLAZ 5104 TPR

PLAZ 5104 TPKT

320

PLAZ 5123 T

PLAZ 5123 TR

PLAZ 5123 TKT

PLAZ 5123 TP

PLAZ 5123 TPR

PLAZ 5123 TPKT

420

PLAZ 5124 T

PLAZ 5124 TR

PLAZ 5124 TKT

PLAZ 5124 TP

PLAZ 5124 TPR

PLAZ 5124 TPKT

320

PLAZ 753 T

PLAZ 753 TR

PLAZ 753 TKT

PLAZ 753 TP

PLAZ 753 TPR

PLAZ 753 TPKT

420

PLAZ 754 T

PLAZ 754 TR

PLAZ 754 TKT

PLAZ 754 TP

PLAZ 754 TPR

PLAZ 754 TPKT

320

PLAZ 773 T

PLAZ 773 TR

PLAZ 773 TKT

PLAZ 773 TP

PLAZ 773 TPR

PLAZ 773 TPKT

420

PLAZ 774 T

PLAZ 774 TR

PLAZ 774 TKT

PLAZ 774 TP

PLAZ 774 TPR

PLAZ 774 TPKT

320

PLAZ 7103 T

PLAZ 7103 TR

PLAZ 7103 TKT

PLAZ 7103 TP

PLAZ 7103 TPR

PLAZ 7103 TPKT

420

PLAZ 7104 T

PLAZ 7104 TR

PLAZ 7104 TKT

PLAZ 7104 TP

PLAZ 7104 TPR

PLAZ 7104 TPKT

320

PLAZ 7123 T

PLAZ 7123 TR

PLAZ 7123 TKT

PLAZ 7123 TP

PLAZ 7123 TPR

PLAZ 7123 TPKT

420

PLAZ 7124 T

PLAZ 7124 TR

PLAZ 7124 TKT

PLAZ 7124 TP

PLAZ 7124 TPR

PLAZ 7124 TPKT

320

PLAZ 1053 T

PLAZ 1053 TR

PLAZ 1053 TKT

PLAZ 1053 TP

PLAZ 1053 TPR

PLAZ 1053 TPKT

420

PLAZ 1054 T

PLAZ 1054 TR

PLAZ 1054 TKT

PLAZ 1054 TP

PLAZ 1054 TPR

PLAZ 1054 TPKT

320

PLAZ 1073 T

PLAZ 1073 TR

PLAZ 1073 TKT

PLAZ 1073 TP

PLAZ 1073 TPR

PLAZ 1073 TPKT

420

PLAZ 1074 T

PLAZ 1074 TR

PLAZ 1074 TKT

PLAZ 1074 TP

PLAZ 1074 TPR

PLAZ 1074 TPKT

320

PLAZ 10103 T

PLAZ 10103 TR

PLAZ 10103 TKT

PLAZ 10103 TP

PLAZ 10103 TPR

PLAZ 10103 TPKT

420

PLAZ 10104 T

PLAZ 10104 TR

PLAZ 10104 TKT

PLAZ 10104 TP

PLAZ 10104 TPR

PLAZ 10104 TPKT

320

PLAZ 10123 T

PLAZ 10123 TR

PLAZ 10123 TKT

PLAZ 10123 TP

PLAZ 10123 TPR

PLAZ 10123 TPKT

420

PLAZ 10124 T

PLAZ 10124 TR

PLAZ 10124 TKT

PLAZ 10124 TP

PLAZ 10124 TPR

PLAZ 10124 TPKT

320

PLAZ 1253 T

PLAZ 1253 TR

PLAZ 1253 TKT

PLAZ 1253 TP

PLAZ 1253 TPR

PLAZ 1253 TPKT

420

PLAZ 1254 T

PLAZ 1254 TR

PLAZ 1254 TKT

PLAZ 1254 TP

PLAZ 1254 TPR

PLAZ 1254 TPKT

320

PLAZ 1273 T

PLAZ 1273 TR

PLAZ 1273 TKT

PLAZ 1273 TP

PLAZ 1273 TPR

PLAZ 1273 TPKT

420

PLAZ 1274 T

PLAZ 1274 TR

PLAZ 1274 TKT

PLAZ 1274 TP

PLAZ 1274 TPR

PLAZ 1274 TPKT

320

PLAZ 12103 T

PLAZ 12103 TR

PLAZ 12103 TKT

PLAZ 12103 TP

PLAZ 12103 TPR

PLAZ 12103 TPKT

420

PLAZ 12104 T

PLAZ 12104 TR

PLAZ 12104 TKT

PLAZ 12104 TP

PLAZ 12104 TPR

PLAZ 12104 TPKT

320

PLAZ 12123 T

PLAZ 12123 TR

PLAZ 12123 TKT

PLAZ 12123 TP

PLAZ 12123 TPR

PLAZ 12123 TPKT

420

PLAZ 12124 T

PLAZ 12124 TR

PLAZ 12124 TKT

PLAZ 12124 TP

PLAZ 12124 TPR

PLAZ 12124 TPKT

320

PLAZ 1553 T

PLAZ 1553 TR

PLAZ 1553 TKT

PLAZ 1553 TP

PLAZ 1553 TPR

PLAZ 1553 TPKT

420

PLAZ 1554 T

PLAZ 1554 TR

PLAZ 1554 TKT

PLAZ 1554 TP

PLAZ 1554 TPR

PLAZ 1554 TPKT

320

PLAZ 1573 T

PLAZ 1573 TR

PLAZ 1573 TKT

PLAZ 1573 TP

PLAZ 1573 TPR

PLAZ 1573 TPKT

420

PLAZ 1574 T

PLAZ 1574 TR

PLAZ 1574 TKT

PLAZ 1574 TP

PLAZ 1574 TPR

PLAZ 1574 TPKT

320

PLAZ 15103 T

PLAZ 15103 TR

PLAZ 15103 TKT

PLAZ 15103 TP

PLAZ 15103 TPR

PLAZ 15103 TPKT

420

PLAZ 15104 T

PLAZ 15104 TR

PLAZ 15104 TKT

PLAZ 15104 TP

PLAZ 15104 TPR

PLAZ 15104 TPKT

320

PLAZ 15123 T

PLAZ 15123 TR

PLAZ 15123 TKT

PLAZ 15123 TP

PLAZ 15123 TPR

PLAZ 15123 TPKT

420

PLAZ 15124 T

PLAZ 15124 TR

PLAZ 15124 TKT

PLAZ 15124 TP

PLAZ 15124 TPR

PLAZ 15124 TPKT

3/79

03_070_083_EN.indd 79

5/3/08 11:21:00

Polyester enclosures completely closed


IP65 (EN 60529)

PLA...

Dimensions (mm)
FIG. 1

PLA...

C-42

2
1
1

B-95

B-95

A-200

A-95

C-170

C-8

A-150

A-150

260

A-95

A-255

C-140
37.5

25

25

75

25

28.5

28.5

B-150

B-150

21
C

FIG. 2

PLA...KT
C-42

A-95

A-253

B-95

B-95

C-170

285/535

285

285/535

A-200
A-150

A-150

C-13

260

A-253

A-95

1
1

A-255

C-140
37.5

25

25

75

25

28.5

28.5

B-150

B-150

21
C

B-120 3
17 / 28*

40
B-205

B = 500 / 750

M8

C-125

B-205

C-125 3

C-140

C-140

M8

37

B-120

405 4

405/655

500/750

500
B =1000/1250

3/80

03_070_083_EN.indd 80

5/3/08 11:21:01

Polyester enclosures with closed top and


open plinth-type base
IP54 (EN 60529)

PLA...T

Dimensions (mm)
FIG. 1

C-42

38

PLA...T

B-95

B-95

A-200

A-95

C-170

260

A-150

A-150

A+38

A-95

C-8

A-255

C-140
37.5

25

25

75

25

28.5

28.5

B-150

B-150

21
C

B-120

B-205

M8

40

C-140

C-125

M8

C-140

37

23 / 28*

C-125

B-120

B-205

B = 500 / 750

405

405/655

500/750

500
B =1000/1250

* For mounting plates with reinforcement wing.

1 Bosses on the back of enclosures starting with 1000 mm wide allow


the fixing of partial mounting plates (see plates section). Bosses at the
top and bottom are used for fixing depth adjustable supports, internal
doors, 19 racks, etc.
In general, all bosses- including those on the sides and on the interior
of the door- are prepared for M8 inserts Ref.: TEX 8 for fixing various
material.
2 Bosses with M8 inserts equipped with studs for fixing the mounting
plates.
3 Centres for floor or plinth fixing.
4 Dimensions of the door opening.

NOTE: in 1250 mm width enclosures, the left door is 500 mm and the right is 750 mm.

3/81

03_070_083_EN.indd 81

5/3/08 11:21:01

Polyester enclosures with self-ventilated


top with canopy and closed base
IP54 (EN 60529)

PLAZ...

Dimensions (mm)
FIG. 1

PLAZ...

C-42

A-95
A-150

260

C-170

C-8

A+55

B-95

A-200

B-95

A-150

A-95

1
1

A-255

C-140

37.5

55

25

25

75

B-150

B-150

28.5

28.5
21
C

FIG. 2

PLAZ...R

C-42

B-95

B-95

1
1

A-200

A-95

A-95

C-170

260

A-150

A-150

C-8

A+55

1
1

A-255

C-140

37.5

55

25

25

75

28.5

B-150

B-150

28.5
21
C

B-60

B-81

6.5

B = 500/750

C-68

M8

B-81

405

6.5

405/655

500/750

500

6.5

37
40

M8

C-160

C-68

23 / 28*

C-160

B-60

B =1000/1250

6.5

3/82

03_070_083_EN.indd 82

5/3/08 11:21:01

Polyester enclosures with self-ventilated


top with canopy and open plinth-type base
IP54 (EN 60529)

PLAZ...T

Dimensions (mm)
FIG. 1

38

PLAZ...T

C-42

A-95

A-95

1
1

1
4

A-200

B-95

B-95

C-170

260

C-8

A+93

A-150

A-150

A-255

C-140

37.5

55

25

25

75

B-150

B-150

28.5

28.5
21
C

B-60

B-81

6.5

B = 500/750

37
40

C-68

M8

C-160

C-68

23 / 28*

M8

B-81

405

6.5

405/655

500/750

500

6.5

C-160 3

B-60

B =1000/1250

6.5

* For mounting plates with reinforcement wing.

1 Bosses on the back of enclosures starting with 1000 mm wide allow


the fixing of partial mounting plates (see plates section). Bosses at the
top and bottom are used for fixing depth adjustable supports, internal
doors, 19 racks, etc.
In general, all bosses- including those on the sides and on the interior
of the door- are prepared for M8 inserts Ref.: TEX 8 for fixing various
material.
2 Bosses with M8 inserts equipped with studs for fixing the mounting
plates.
3 Centres for floor or plinth fixing.
4 Dimensions of the door opening.

NOTE: in 1250 mm width enclosures, the left door is 500 mm and the right is 750 mm.

3/83

03_070_083_EN.indd 83

5/3/08 11:21:02

PLA

Composition accessories

Horizontal coupling frame for PLA and PLA...T enclosures


PVC frame with sealing gasket that permits lateral coupling of enclosures PLA
or PLA...T.
Enclosure dimensions
Reference
Height (A)

Depth (C)

500

320

MUPLA 53

750

320

MUPLA 73

1000

320

MUPLA 103

1250

320

MUPLA 123

1500

320

MUPLA 153

500

420

MUPLA 54

750

420

MUPLA 74

1000

420

MUPLA 104

1250

420

MUPLA 124

1500

420

MUPLA 154

SUPLA...

MUPLA...

SUPLA...

MUPLA...

Supplements for coupling PLA and PLA...T enclosures


They complement the MUPLA coupling frame for lateral union of enclosures.
2 versions: SUPLA for enclosures without canopy and SUPLAT for enclosures
with canopy.
Enclosure dimensions
PLA

PLA...T

Depth (C)
320

SUPLA 3

SUPLA 3T

420

SUPLA 4

SUPLA 4T

3/84

03_084_100_EN.indd 84

2/4/08 12:55:05

PLA

Composition accessories

Vertical coupling of enclosures


Coupling enclosures using an adhesive gasket that guarantees watertightness
at the vertical joint of the enclosures PLA.
Ref.: UVPLA.
Application

Reference

Adhesive gasket

UVPLA

Canopies
Made of reinforced pressed polyester, for exterior installation of closed
enclosures.
c Colour RAL-7032.
c Self-extinguishable; high resistance to impacts and temperature.
c Excellent resistance to outdoor conditions.
c The nominal height of the enclosure is increased 38 mm.

A + 38

For attachment to enclosures

C = 320/420

Reference
Width (B)

Depth (C)

No. of doors

500

320

TJPLA 53

750

320

TJPLA 73

1000

320

TJPLA 103

1250

320

TJPLA 123

500

420

TJPLA 54

750

420

TJPLA 74

1000

420

TJPLA 104

1250

420

TJPLA 124

3/85

03_084_100_EN.indd 85

2/4/08 12:55:06

PLA

a
Composition accessories

Bases

To be coupled to enclosures with closed bases, Ref.: PLA


Made of fiberglass reinforced polyester.
c Colour RAL-7032.

c Self-extinguishable; high resistance to impacts and temperature.


c Excellent resistance to outdoor conditions.

For attachment to enclosures

Reference

30

20

65

B+

0/4

20

60

Width (B)

Depth (C)

No. of doors

500

320

ZNPLA 53

750

320

ZNPLA 73

1000

320

ZNPLA 103

1250

320

ZNPLA 123

500

420

ZNPLA 54

750

420

ZNPLA 74

1000

420

ZNPLA 104

1250

420

ZNPLA 124

a
Plinths

To be coupled to enclosures with open bases, Ref.: PLAZ


Made of fiberglass reinforced polyester.
c Colour RAL-7032.

c Self-extinguishable; high resistance to impacts and temperature.


c Double insulation; excellent resistance to weather conditions.
c 200 mm front cover accessible from the interior.

c 305 mm height fixed front panel, allowing the enclosure to be completely or


partially flush built in.
c Fixing profile for cable entry.

c Sides with knock-out entry PG-36.

For attachment to enclosures

Reference

395

305

200

Width (B)

Depth (C)

No. of doors

500

320

ZHPLA 53

750

320

ZHPLA 73

1000

320

ZHPLA 103

1250

320

ZHPLA 123

500

420

ZHPLA 54

750

420

ZHPLA 74

1000

420

ZHPLA 104

1250

420

ZHPLA 124

B+35

C10

3/86

03_084_100_EN.indd 86

2/4/08 12:55:06

PLA

Composition accessories

Cable entry plate


To be coupled to the models of enclosures with open plinth-type bases,
Ref.: PLAZ
Made of fiberglass reinforced polyester.
c Colour RAL-7032.
c Self-extinguishing; excellent resistance to outdoor conditions.
c Easily machined.
For attachment to enclosures
Reference
Width (B)

Depth (C)

No. of doors

500

320

ECPLAZ 53

750

320

ECPLAZ 73

1000

320

ECPLAZ 103

1250

320

ECPLAZ 123

500

420

ECPLAZ 54

750

420

ECPLAZ 74

1000

420

ECPLAZ 104

1250

420

ECPLAZ 124

2-door enclosures

B-40

21

430

10

C-78

C-204

11
10

31

25

10

C-78

C-204

11

63

63

1-door enclosures

25

100
B-40

Wall mounting kit


Set of 6 metal pieces in passivated zinc-coated steel.
c Fixing to the sides with 4 or 6 pieces in horizontal (1).
c In all cases, the maximum admissible load is that which corresponds to
150 kg/m2 of plate surface. See the enclosure lifting table, page 3/111.

187,5

Ref.: FMPLA.

A-375

(1)

26
B+52

3/87

03_084_100_EN.indd 87

2/4/08 12:55:08

PLA

Composition accessories

Floor-fixing frame
Frame for fixing those enclosures with open plinth-type bases directly to the
floor, Ref.: PLAZ
Fixing enclosures with open bases to the floor, Ref.: PLA is done directly,
with the solution being a stud with a standard screw via the ZNPLA bottom.
C-

16

For attachment to enclosures


Reference
Width (B)

60

B-

Depth (C)

No. of doors

500

320

MFPLAZ 53

750

320

MFPLAZ 73

1000

320

MFPLAZ 103

1250

320

MFPLAZ 123

500

420

MFPLAZ 54

750

420

MFPLAZ 74

1000

420

MFPLAZ 104

1250

420

MFPLAZ 124

Set of 4 studs for floor fixing


Ref.: FS/PLA2.

Door retainer
RET/PLAU

Door retainers to be directly incorporated into the indicated enclosures.


c Opening of the retainer: 90 or 120 for all models. Ref. RET/PLAU.
c Opening of the retainer: 110 for models PLA, PLA...T and PLAZ.
Ref. RET/PLA.

RET/PLA

3/88

03_084_100_EN.indd 88

2/4/08 12:55:09

PLA

Composition accessories

Internal doors
Internal door manufactured in painted aluminium, grey RAL-7032.
Double bar locks, allowing change for triangle, square, etc. inserts of CRN
enclosures (see general catalogue).
In enclosures with a closed bottom, Ref.: PLA, the internal PIPLA doors are
coupled directly.

In models with open plinth-type base, Ref.: PLAZ..., the PTZ adapter plates
must be ordered separately (see footnote).

25
30*
C-40

Depth of the positioning of the internal door is adjustable 25 mm.


* In enclosures with a transparent KT door, subtract 5 mm.

For attachment to enclosures


No. of doors
Height (A)

Total lower door reference*

Width (B)

Individual internal doors


in 2-door enclosure reference*

Dimensions
D

Weight
(kg)

500

500

PIPLA 55

398

398

1.6

500

750

PIPLA 57

398

648

2.2

500

1000

PIPLA 55 + PIPLA 55

500

1250

PIPLA 55 + PIPLA 57

750

500

PIPLA 75

648

398

2.2

750

750

PIPLA 77

648

648

3.1

750

1000

PIPLA 75 + PIPLA 75

750

1250

PIPLA 75 + PIPLA 77

1000

500

PIPLA 105

898

398

2.8

PIPLA 107

4.1

1000

750

898

648

1000

1000

PIPLA 105 + PIPLA 105

1000

1250

PIPLA 105 + PIPLA 107

1250

500

PIPLA 125

1148

398

3.4

PIPLA 127

1250

750

1148

648

1250

1000

PIPLA 125 + PIPLA 125

1250

1250

PIPLA 125 + PIPLA 127

1500

500

PIPLA 155

1398

398

PIPLA 157

1500

750

1398

648

1500

1000

PIPLA 155 + PIPLA 155

1500

1250

PIPLA 155 + PIPLA 157

* To be coupled to enclosures with open bottom, Ref.: PLAZ, adaptor plates must be ordered separately, Ref.: PTZ 320 or PTZ 420, for 320 or 420 mm depth one-door enclosures.
PTZ 320/2P or PTZ 420/2P must be ordered for two-door enclosures.

3/89

03_084_100_EN.indd 89

2/4/08 12:55:10

PLA

Composition accessories

Standard lock for completely closed enclosures


CHANGING INSERTS OF THE STANDARD LOCK
Specifications

Type of lock

Type of operation

Reference

6.5 mm triangle
lock, operated

TT6/CRN

with key LT6,5.


7 mm triangle
ock, operated

TT7/CRN

with key LT8.


8 mm triangle
lock, operated

Direct-action 5 mm double bar lock, operated with key


LDB5. Included in standard supply.
Accepts all the types of operation referenced in the following
table by changing the inserts of the standard lock.

TT8/CRN

with key LT8.


6 mm square
lock, operated

TC6/CRN

with key LC7.


7 mm square
lock, operated

TC7/CRN

with key LC7.


8 mm square
lock, operated

TC8/CRN

with key LC8.


Double bar
lock, operated
with key LDB5.

TDB/PLA

Included in
standard supply.

Padlock

BC/PLA

CHANGING TO HANDLE LOCK


Specifications

Type of operation

Reference

Embellishing kit
with handle lock.*

EBM/PLA*

Embellishing kit for direct-action key-operated lock (without


handle): Ref.: EB/PLA.
* To obtain the complete lock, in addition to the EBM/PLA trim, the T/OLN
cated on the following page, must be ordered separately.

or T/PLA

types of locks, indi-

3/90

03_084_100_EN.indd 90

2/4/08 12:55:11

PLA

Composition accessories

Standard lock for enclosures with open top or open base


CHANGING INSERTS OF THE STANDARD LOCK
Specifications

Type of lock

Type of operation

Reference

7 mm triangle
lock, operated

TT7/OLN

with key LT8.


8 mm triangle
lock, operated

TT8/OLN

with key LT8.


6 mm square
lock, operated

TC6/OLN

with key LC7.


7 mm square
lock, operated

TC7/OLN

with key LC7.


8 mm square
lock, operated

Double bar handle lock, operated by key LDB5. Included in


standard supply.
Accepts all the types of operation referenced in the following
table by changing the inserts.

TC8/OLN

with key LC8.

Lock with key type 405.

TL/OLN

Lock with key type JIS.

TJIS/OLN

Lock with reinforced-type key

TLR/OLN

Lock with key type FAC.

TFAC/OLN

DIN insert
adapter.

ABDIN/OLN

Pushbutton operated.

TS/PLA

5 mm double
bar lock included

TDBM/PLA

in standard supply.

Handle lock with

CBCM/PLA*

padlocking device.*

Protective cover (optional).

TPBM/PLA

CHANGING TO LOCK WITHOUT HANDLE


Specifications

Type of lock

Type of operation

Reference

Embellishing kit without


handle lock.**

EB/PLA**

Embellishing kit with handle Ref.: EBM/PLA.


* To obtain the complete lock, in addition to the CBCM/PLA trim, the T/OLN type of lock, indicated on this
page, must be ordered separately.
** To obtain the complete lock, in addition to the EB/PLA trim, the T/CRN or TDB/PLA types of locks, indicated on the previous page, must be ordered separately.

3/91

03_084_100_EN.indd 91

2/4/08 12:55:12

PLA

Composition accessories

Transparent protective screens


Made of 4 mm transparent polycarbonate. Supplied without the SPTR 77
support set, which must be purchased separately.

A - 158

Enclosure dimensions

27

11

C - 170

C - 116

Reference

21

A - 200

Height

Width

500

500

PPTR 55

500

750

PPTR 57

750

500

PPTR 75

750

750

PPTR 77

21

Fixing supports for protective screens


Support set made of the fixing supports and all the necessary hardware, for
fixing the PPTR transparent protective screens to the corresponding PLA
enclosures.
Reference
SPTR 77

Application
PPTR 55/57/75/77

3/92

03_084_100_EN.indd 92

2/4/08 12:55:13

PLA

Mounting accessories

Metal mounting plates


Made of galvanised steel sheet, with reinforcement fold on models starting
with a height of 1000 mm.
Directly joined to the bottom of the enclosure itself or to the depth adjustable
supports.
On two-door enclosures, a full plate or 2 partial plates may be fitted. See table.
Enclosures starting with a height of 1000 mm are equipped with intermediate
fixing bosses so the PMM plates of a height less than the nominal height
of the enclosure can be positioned (see note (1) below). In this case, inserts
Ref.: TEX 8 must be ordered separately.
c Maximum load 150 kg/m2.

10.5

25

25

25

25

6.5

8.5

8.5

6.5
8.5

25

25

6.5

25

25

25

10.5

25

8.5 6.5

10.5
25

25

100
100

75

75

10.5

150
G

350

437.5

150

12.5

H-87.5
H

models from PMM 1010


FIG. 1

To couple to enclosures with


dimensions (1)

FIG. 2

Individual plates, two-door


enclosures

Full plate
No. of doors

500

500

PMM 55

390

375

350

350

2.5

500

750

PMM 75

640

375

600

350

3.8

500

1000

PMM 510

PMM 55 + PMM 55

390

875

350

-0

437.5

2.5

6.3

500

1250

PMM 55 + PMM 75

-0

-0

-0

-0

750

500

PMM 75

640

375

600

350

3.8

750

750

PMM 77

640

625

600

600

2.5

7.8

750

1000

PMM 710

PMM 75 + PMM 75

640

875

600

-0

437.5

2.5

10.6

PMM 75 + PMM 77

17.6

Height (A)

Reference

Width (B)

Fig. No.

Reference

Dimensions full plate

Fig. No.

(kg)

750

1250

PMM 712

640

1125

600

-0

687.5

2.5

1000

500

PMM 105

890

375

850

350

2.5

6.5

1000

750

PMM 107

890

625

850

600

2.5

10.8

1000

1000

PMM 1010

PMM 105 + PMM 105

875

875

850

-0

437.5

2.5

15

1000

1250

PMM 1012

PMM 105 + PMM 107

875

1125

850

-0

687.5

2.5

19.3

1250

500

PMM 125

1125

375

1100

350

2.5

8.6

1250

750

PMM 127

1125

625

1100

600

2.5

14.2

1250

1000

PMM 1210

PMM 125 + PMM 125

1125

875

1100

-0

437.5

2.5

19.4

1250

1250

PMM 1212

PMM 125 + PMM 127

1125

1125

1100

-0

687.5

2.5

24.9

1500

500

PMM 155

1375

375

1350

350

2.5

10.6

1500

750

PMM 157

1375

625

1350

600

2.5

17.3

1500

1000

PMM 1510

PMM 155 + PMM 155

1375

875

1350

-0

437.5

2.5

23.8

1500

1250

PMM 1512

PMM 155 + PMM 157

1375

1125

1350

-0

687.5

2.5

30.5

(1) Enclosures of 1000, 1250 and 1500 mm height allow as partial plates: 2 PMM of 500; 1 of 500 + 1 of 750 or 2 of 750 mm height, respectively, fixed at the back of the enclosure

3/93

03_084_100_EN.indd 93

2/4/08 12:55:15

PLA

Mounting accessories

Insulating mounting plates


Made of bakelite in black RAL-9005 (Ref.: PMB..) or in polyester in grey
RAL-7032 (Ref.: PMA..).
Directly joined to the bottom of the enclosure itself or to the depth adjustable
supports.
On two-door enclosures, a full plate or 2 partial plates may be fitted. See table.
Bakelite

Enclosures starting with a height of 1000 mm are equipped with intermediate


fixing bosses so the PMB plates of a height less than the nominal height of
the enclosure can be positioned (see note (1) below). In this case, inserts
Ref.: TEX 8 must be ordered separately.

Polyester

c Maximum load 150 kg/m2.

10.5

10.5

10.5

100
100

75

75

10.5

150
G

350

437.5

150

H-87.5
H

FIG. 1

To couple to enclosures
with dimensions (1)

FIG. 2

Reference (2)

Dimensions full plate

Fig. No.

Reference (2)

Fig. No.

(kg)

500

500

PM.. 55

390

375

350

350

0.9

500

750

PM.. 75

640

375

600

350

1.3

500

1000

PM.. 510

PM.. 55 + PM.. 55

390

875

350

-0

437.5

2.4

500

1250

PM.. 55 + PM.. 75

-0

-0

-0

-0

750

500

PM.. 75

640

375

600

350

1.3

750

750

PM.. 77

640

625

600

600

2.8

750

1000

PM.. 710

PM.. 75 + PM.. 75

640

875

600

-0

437.5

3.9

750

1250

PM.. 712

PM.. 75 + PM.. 77

640

1125

600

-0

687.5

1000

500

PM.. 105

890

375

850

350

2.3

1000

750

PM.. 107

890

625

850

600

3.9

1000

1000

PM.. 1010

PM.. 105 + PM.. 105

890

875

850

-0

437.5

5.5

1000

1250

PM.. 1012

PM.. 105 + PM.. 107

890

1125

850

-0

687.5

7.1

1250

500

PM.. 125

1140

375

1100

350

1250

750

PM.. 127

1140

625

1100

600

1250

1000

PM.. 1210

PM.. 125 + PM.. 125

1140

875

1100

-0

437.5

1250

1250

PM.. 1212

PM.. 125 + PM.. 127

1140

1125

1100

-0

687.5

1500

500

PMB 155

1390

375

1350

350

3.7

1500

750

PMB 157

1390

625

1350

600

6.1

1500

1000

PMB 1510

PMB 155 + PMB 155

1390

875

1350

-0

437.5

8.6

1500

1250

PMB 1512

PMB 155 + PMB 157

1390

1125

1350

-0

687.5

Height (A)

Width (B)

Individual plates, two-door


enclosures

Full plate

No. of
doors

11

(1) Enclosures of 1000, 1250 and 1500 mm height allow as partial plates: 2 PM.. of 500; 1 of 500 + 1 of 750 or 2 of 750 mm height, respectively, fixed at the back of the enclosure.
(2) PMA: polyester, PMB: bakelite.

3/94

03_084_100_EN.indd 94

2/4/08 12:55:19

PLA

Mounting accessories

Universal perforated mounting plates


Plates specially designed for quick mounting of equipment using the TFP
locking nuts. Made of zinc-coated steel.
Directly joined to the bottom of the enclosure itself or to the depth adjustable
supports.
Possibility of incorporating 2 individual plates on two-door enclosures. See
table.
Enclosures starting with a height of 1000 mm are equipped with intermediate
fixing bosses so the PMR plates of a height less than the nominal height of
the enclosure can be positioned (see note (1) below). In this case, inserts
Ref.: TEX 8 must be ordered separately.

D
F

c Maximum load 150 kg/m2.

15

To join the enclosures (1)

Full plate

Individual plates, two-door


enclosures

Reference

Reference

No. of doors

Dimensions full plate

500

500

PMR 55

370

376

350

350

Thickness
(mm))
2

500

750

PMR 57

370

626

350

600

500

1000

PMR 55 + PMR 55

370

376/376

350

350/350

500

1250

PMR 55 + PMR 57

370

376/626

350

350/600

750

500

PMR 75

620

376

600

350

1.7

750

750

PMR 77

620

626

600

600

2.7

750

1000

PMR 75 + PMR 75

620

376/376

350

350/350

750

1250

PMR 75 + PMR 77

620

376/626

350

350/600

1000

500

PMR 105

870

376

850

350

2.1

PMR 107

Height (A)

Width (B)

Weight (kg)
1.1
1.7

1000

750

870

626

850

600

4.1

1000

1000

PMR 105 + PMR 105

870

376/376

850

350/350

1000

1250

PMR 105 + PMR 107

870

376/626

850

350/600

1250

500

PMR 125

1120

376

1100

350

3.3

PMR 127

1250

750

1120

626

1100

600

4.8

1250

1000

PMR 125 + PMR 125

1120

376/376

1100

350/350

1250

1250

PMR 125 + PMR 127

1120

376/626

1100

350/600

1500

500

PMR 155

1370

376

1350

350

4.2

PMR 157

1500

750

1370

626

1350

600

6.3

1500

1000

PMR 155 + PMR 155

1370

376/626

1350

350/350

1500

1250

PMR 155 + PMR 157

1370

376/626

1350

350/600

(1) Enclosures of 1000, 1250 and 1500 mm height allow as partial plates: 2 PMM of 500; 1 of 500 + 1 of 750 or 2 of 750 mm height, respectively, fixed at the back of the enclosure.

3/95

03_084_100_EN.indd 95

2/4/08 12:55:21

PLA

Mounting accessories

Set of adjustable mounting plate supports


c Allow for depth adjustment of PMM, PMB and PMR mounting plates, on
any model of enclosure.
c Set of 4 adjustable supports on the profile of the aluminium guide, able to
be fixed at any point along its entire length and with reference positioning
every 25 mm.
DPLA 420

c Models with a closed base. Ref.: PLA...


The DPLA adjustable supports can be coupled directly without the need
for other accessories.
C-70
62*

35

Detail of DPLA plate supports in enclosure with closed base.

c Models with open plinth-type base. Ref.: PLAZ...


In addition to the DPLA adjustable supports, a set of PTZ adaptor plates
must be ordered.

C-70
62*

35

PTZ 420

* For enclosures with a transparent KT door, subtract 5 mm.

PTZ 420/2P

c Two-door models
Two sets of DPLA adjustable supports must be ordered, and for the
models open bottom, add one PTZ.../2P set.
To be installed in enclosures

enclosure with open plinth-type base, reference


PLAZ , with two doors, with adjustable plate
fixed with DPLA supports and PTZ adaptor
plates.

To be installed in enclosures reference

Depth (C)

No. of doors

320

PLA...

420

320

(2)

DPLA 320*

(2) DPLA 320* + PTZ 320/2P

420

(2)

DPLA 420*

(2) DPLA 420* + PTZ 420/2P

DPLA 320
DPLA 420

PLAZ...
DPLA 320 + PTZ 320
DPLA 420 + PTZ 420

* In two-door enclosures, in order to mount a full plate or two individual plates, 2 DPLA plate fixing sets must
be ordered, as indicated in the table.

Set of fixing supports for additional plate


Set of 4 adjustable fixing supports for fixing an additional plate.
Ref.: EDPLA.
Detail of the DPLA plate supports with an additional set of fixing supports,
Ref.: EDPLA, allowing the placement of two plates (back to back), for
example in enclosures with a rear door.

3/96

03_084_100_EN.indd 96

2/4/08 12:55:22

PLA

Mounting accessories

Universal chassis system


Universal chassis made up of a set of 2 MOL profiles prepared for partial
mounting plates and DIN rails, for fixing any type of equipment.
The chassis can be fixed directly to the back of the enclosure or on the set
of adjustable mounting plate supports, in this case making depth adjustment
possible.
In two-door enclosures with 1000 and 1250 mm width, two 500 mm
chassis, or 1 of 500 + 1 of 750 mm width, respectively, can be mounted.

CDP double profile DIN rail for direct


fixing of equipment. Detail of the TDC
sliding nut.

Detail of the MOL profile and TDM nut.


The notches in the profile permit
adjustment every 2.5 mm.

Set of profiles for universal chassis


Set of two vertical profiles for direct fixing to the back of the enclosure.
The notches in the profile every 2.5 mm and the marks every 25 mm
facilitate the positioning of plates, rails, etc.
To make depth adjustment of the chassis possible, the MOL profiles must
be fixed on a set of DPLA or DPLA + PTZ adjustable mounting plate
supports, as in the following table.
To be installed in enclosures

To be installed in enclosures reference

Depth (C)

No. of doors

320

PLA...

420

DPLA 420

320

(2) DPLA 320

(2) DPLA 320 + PTZ 320/2P

420

(2) DPLA 420

(2) DPLA 420 + PTZ 420/2P

DPLA 320

To couple to enclosures with height (A)

Detail of the MOL profile fixed to the back of the enclosure.

PLAZ...
DPLA 320 + PTZ 320
DPLA 420 + PTZ 420

Reference

750

MOL 75

1000

MOL 100

1250

MOL 125

1500

MOL 150

Detail of the MOL profile fixed to the set of DPLA adjustable


plate support.

3/97

03_084_100_EN.indd 97

2/4/08 12:55:24

PLA

Mounting accessories

Partial mounting plates for universal chassis


Made of galvanised steel. They are placed on the MOL profiles using TDM 8
nuts and TOR 16/8A screws, which must be ordered separately.

To couple to enclosures with


width (B)

B-95

Plate height
(H)

Reference

500

247

PMP 2550

750

247

PMP 2575

1000*

247

PMP 25100

500

397

PMP 4050

750

397

PMP 4075

1000*

397

PMP 40100

* The 1000 mm width enclosures allow for mounting 2 chassis with PMP...50 plates.

Lateral mounting plates


Insulating polyester mounting plates, to be installed on the side of PLA
enclosures.
The TEX8 inserts must be ordered separately.
Enclosure dimensions
Reference
Height

B - 100

40
20

44,5

45

10

Depth

500

320

PMLA 53

500

420

PMLA 54

750

320

PMLA 73

750

420

PMLA 74

1000

320

PMLA 103

1000

420

PMLA 104

1250

320

PMLA 123

1250

420

PMLA 124

A - 100

40

44,5

3/98

03_084_100_EN.indd 98

2/4/08 12:55:31

PLA

Mounting accessories

Metal rails and nuts


Rails of galvanised steel. They are placed on the MOL profiles using TDM 6
nuts and TOR 12/6A screws, which must be ordered separately.

To couple to enclosures
with width (B)

Symmetric DIN
reference
35 7.5

Symmetric DIN
reference
35 15

Asymmetric DIN
reference

Double profile
reference

500

CSPLA 50

CAPLA 50

750

CSPLA 75

CAPLA 75

1000

CSPLA 100

CAPLA 100

In 2 metre strips

CO 35

CA 32

In 2 metre strips

COT 35

CAT 32

CDP 200
-

In 2 metre strips

CO 35/15

In 2 metre strips

COT 35/15

* The 1000 mm width enclosures allow for mounting 2 chassis with C...50 rails.

MOUNTING ACCESSORIES
Nuts for fixing equipment
Thread type

(1)

Nuts for MOL profiles

Fixing screw with washer

(2)
Units per
package

Units per
package

Units per package

Length (mm)

Units per package

100

M4

TDE 4

100

100

TOR 10/4A

10

M4

TOR 16/4A

16

100

M5

TDE 5

100

TOR 12/5A

12

100

M5

TDC 56

100

TOR 18/5A

18

100

M6

TDE 6

100

TDC 56

100

TDM 6

10

TOR 12/6A

12

100

M6

TOR 18/6A

18

100

M8

TDM 8

10

TOR 16/8A

16

50

M8

TOR 20/8A

20

10

TOR 16/5AT

16

100

Sheet 4.8 mm
(1) For symmetrical rails, Ref.: CO, COT and CSPLA, and double profile CDP...
(2) For double profile rails CDP...

3/99

03_084_100_EN.indd 99

2/4/08 12:55:33

PLA

Mounting accessories

Support tray
BANPLA tray to be placed horizontally to support various materials, or simply
as a separator. Designed to be installed in one-door enclosures.
It is mounted directly on the bottom of the enclosure using the lateral bosses.
If you want to place the tray, or various trays, at differing heights, 2 sets of 2
SPLA vertical profiles (total of 4), must be ordered, as indicated in the table.
Maximum load:
Depth 320: 60 kg
Depth 420: 50 kg

To couple to enclosures (1)

C-100

25

12

27

18

Height (A)

Width (B)

Tray

Supports*

500

500

320

BANPLA 53

500

750

320

BANPLA 73

750

500

320

BANPLA 53

2 SPLA 75

Depth (C)

750

750

320

BANPLA 73

2 SPLA 75

1000

500

320

BANPLA 53

2 SPLA 100

1000

750

320

BANPLA 73

2 SPLA 100

1250

500

320

BANPLA 53

2 SPLA 125

1250

750

320

BANPLA 73

2 SPLA 125

1500

500

320

BANPLA 53

2 SPLA 150

1500

750

320

BANPLA 73

2 SPLA 150

500

500

420

BANPLA 54

500

750

420

BANPLA 74

750

500

420

BANPLA 54

2 SPLA 75

750

750

420

BANPLA 74

2 SPLA 75

1000

500

420

BANPLA 54

2 SPLA 100

1000

750

420

BANPLA 74

2 SPLA 100

1250

500

420

BANPLA 54

2 SPLA 125

1250

750

420

BANPLA 74

2 SPLA 125

1500

500

420

BANPLA 54

2 SPLA 150

1500

750

420

BANPLA 74

2 SPLA 150

* Are only necessary if you want to place the tray at differing heights.
(1) For the 1250 mm enclosures, these trays may be placed using the SBPLA profiles, on the 500 and
750 mm side.

200

200

200

200

11x13

250

12

B-42

Reference

19 rack support and trays for two-door enclosures


For 19 RACK accessories, consult the VDI catalogue.
Ref.: SB/PLA.

3/100

03_084_100_EN.indd 100

2/4/08 12:55:38

PLA

Current distribution accessories

GCR ties
Clip in fasteners to be installed directly on 19 racks and on slotted MR
mounting plates.
Reference: GCR.

Adjustable ties
Made of 6.6 nylon in natural colour or black for outdoor conditions.
Reference

Use
L

minimum

maximum

White

Black

LZ25100

LN25100

100

2.5

1.6

22

LZ25200

LN25200

200

2.5

1.6

49

LZ35150

LN35150

150

3.5

1.6

35

LZ35200

LN35200

200

3.5

1.6

49

LZ35300

LN35300

300

3.5

1.6

75

LZ46150

LN46150

150

4.6

1.6

36

LZ46200

LN46200

200

4.6

1.6

49

LZ48270

LN48270

270

4.8

1.6

73

LZ46390

LN46390

390

4.6

1.6

109

LZ76390

LN76390

390

7.6

4.7

108

Tightening tools
To tighten and cut to size the adjustable ties. They facilitate wiring and save
time, preventing the packets of cables from loosening.
Tool adjustable according to the thickness of the tie. Can be used with the
following models: LZ25100 up to LZ46390. Ref.: MARK3.
A very light and ergonomic tool, the cut on the tie is done by twisting the
tool. Can be used on the following models of ties: LZ25100 up to LZ46390.
Ref.: MARK20, 21.
Reference
MARK3

Admissible width
ties
2.5 4.8

Reference

Admissible width
ties

MARK20

2.5 4.8

MARK21

4.6 7.6

3/101

03_101_107_EN.indd 101

2/4/08 12:57:00

PLA

Current distribution accessories

Locking clips
Allows fixing ties from the series LZ25100 up to LZ46390 on panels up to
3.2 mm thick. Material: 6.6 nylon.
perforation
mm

Maximum width
panel mm

SFC1

3.2

SFC2

Reference

SFC2

SFC1

Fig. 1

Figure

Fig. 2

Stud
To use with soft materials: 7 mm hole, or hard materials: 8 mm hole.
Ties are attached up to 9 mm width. Material: 6.6 nylon
Ref.: LOK01.

Tie fixing support


To attach one or two ties, mounted with a single screw. Material: 6.6 nylon.
Allows for attaching ties from the entire range.
Reference

Fixing screw

Admissible width
ties

KR6

12

18

M4

2.5 4.8

KR8

14.5

25

12

M6

2.5 7.6

3/102

03_101_107_EN.indd 102

2/4/08 12:57:01

PLA

Current distribution accessories

Support heads
To transform normal ties into ties with fixing heads, introduce a tie into this
head before closing it on the cable bundle. Material: 6.6 nylon.

Reference

Fixing screw

Admissible
width ties

FH18

7.1

13.3

M4

2.5

FH30

9.5

17.9

4.7

M5

3.5

FH50

11.3

22.2

6.2

M6

4.7

Self-adhesive support base


Permits insertion of 1 tie from 4 points at a 90 angle. Attaches ties from the
series LZ25100 up to LZ46390. Material: 6.6 nylon.
Reference

Admissible width
ties

MB3A

19.1

19.1

4.8

3.2

13.2

2.5 3.5

MB4A

28.5

28.5

5.5

20.2

2.5 4.8

adhesive support

Tie fixing support


To attach ties from any series. Material: 6.6 nylon.
Reference
LKC

Admissible width
ties mm
2.5 7.6

Fixing screw
M5

3/103

03_101_107_EN.indd 103

2/4/08 12:57:03

PLA

Current distribution accessories

Lateral tie fixing support


Covers the head of the tie in its end, thus obtaining neater cabling.
Material: 6.6 nylon.
Reference

Admissible width
ties mm

LKM/HE

2.5 7.6

Fixing screw
M5

Fixing loop for tubes, hoses, etc.


2 versions, fixed and graduated, from 5 to 25.4 mm. Material: black
6.6 nylon.
Reference

3.5

6.2

13.7

NX3

3.9

9.4

20.5

NX5

12

3.9

9.4

24

NX8*

14.3 15.8

1.3

12.6

32

NX1

min. - max.

NX11

17.4 20

NX14

22.2 25.4

1.3

12.6

37

4.3

1.5

16

45

*The NX8 model only has 3 adjustment holes.

NX 1-3-5

NX 8-11-14

3/104

03_101_107_EN.indd 104

2/4/08 12:57:04

PLA

Current distribution accessories

Adjustable membrane glands


Insulating membrane glands made of PVC with entry that can be adjusted
for cables.

Fig. 1

Fig. 2

Capacity
Reference

Fig.

B*

ECPC-3

25

21.5

18

3.2

13

5 to 18

Pg 9 to 11

ECPC-5

33

29.5

ECPC-6

43

38.5

26

3.2

20

5 to 26

Pg 9 to 16

36

3.2

22

5 to 36

ECPC-9

70

Pg 9 to 21

63

60

28

20

28 to 60

ECPC-15

98

Pg 21 to 48

90

87

28

23

28 to 87

Pg 21 to 48

Tube

cable

* Mounting perforation.

Protective sleeves
Small protective sleeves for cables coming out of tubes, as indicated in the
instructions for MI BT 019. Made of flexible and durable PVC, in light grey
colour.
A

PC-1

15.2

12.7

PC-2

18.6

16

Pg 11

PC-3

20.4

17.8

Pg 13.5

PC-4

22.5

19.8

Pg 16

PC-5

28.3

25.3

Pg 21

PC-6

37

33.6

Pg 29

PC-7

47

43

Pg 36

Tube
Pg 9

Reference

3/105

03_101_107_EN.indd 105

2/4/08 12:57:04

PLA

Current distribution accessories

Useful information about Pg tubes and HIMEL accessories to be coupled


MODELS, DIMENSIONS AND REFERENCES
Tubes

HIMEL accessories to be coupled


perforations to

interior
Designation

exterior

Steel
Flexible
steel

PVC

Cables inserted*
Flexible
steel with
PVC

2.5

Insert

Thread

4
Pg 9

15.2

12.7

12.4

12

11.1

To the perforations

To the tubes

No. of conductors

Adjustable
membrane
glands

Plain plugs

PC-1

PC-2

EC-2

Protective
Adjustable
sleeves
membrane glands
EC-1 to EC-7

16

14

ECPC-3 to ECPC-6
ECN-5 to ECN-10

Pg 11

18.6

16

15.5

14.5

10

2.5

14.2

16

EC-2 to EC-7
4

2.5

19

17.5

25

ECPC-5; ECPC-6

EC-1

ECN-5 to ECN-10
EC-3 to EC-7

Pg 13.5

20.4

17.8

17.5

16.3

16

35

10

21

19.5

ECPC-5; ECPC-6

TC-1

ECN-1
EC-3
PC-3

ECPC-3

TC-2

PC-4

EC-4

TC-3

ECN-5 to ECN-10
EC-4 to EC-7
Pg 16

22.5

19.8

18.7

18.5

17.6

50

16

10

23

21.5

ECPC-5; ECPC-6
ECN-5 to ECN-10
EC-5 to EC-7

Pg 21

28.3

25.3

24.7

23

23

70

25

16

10

29

27

ECPC-6 to ECPC-15

EC-5
PC-5

ECPC-5

ECN-6 to ECN-10
Pg 29

37

33.6

33.5

31

31

95

35

25

16

120

50

35

25

EC-6; EC-7
38

35.5

150
47

43

41.5

41

40.3

240

35
70

50

50

48

45.5

Pg 48

54

50

60

48

56

48

54.2

52.5

47
51.4

EC-6

TC-5

ECPC-6

TCP-5

ECN-6

EC-7

300
Pg 42

PC-6

ECN-7; ECN-10

185
Pg 36

ECPC-9; ECPC-15

TC-4

ECN-5

EC-7

ECPC-9; ECPC-15

PC-7

ECN-7

TC-6

ECN-10
95

70

120

95

70

120

95

150

120

150

ECPC-9; ECPC-15
55

52.5

ECN-10

ECPC-9; ECPC-15
61

58

ECN-10

* Number and section in mm2 of the conductors that may be housed inside each tube (orientative).
For more information, consult the electrotechnical rules for low voltage (MI BT 019).

Bimetal BBH terminals


BBH-29

BBH-29D

Terminals especially designed for branching cables on plates; their main


application is busbar connection.
BBH terminals are made of a tinned, hot cast copper alloy and are suitable
for connecting to a conductor of copper or aluminium indistinctly (bimetal).

Reference

BBH-29P

BBH-29DP

Main section
(mm2)

Bypass section
(mm2)

Reference

Main section
(mm2)

Bypass section
(mm2)

BBH-29

6-50

BBH-29P

6-50

BBH-29C*

6-50

BBH-29PC*

6-50

BBH-30

10-95

BBH-29DP

6-50

6-50

BBH-31

16-150

BBH-29DPC*

6-50

6-50

BBH-32

50-240

BBH-29D

6-50

6-50

BBH-29DC*

6-50

6-50

BBH-30D

10-95

10-95

BBH-31D

25-150

16-150

BBH-32D

95-240

5-240

* Include terminal cover CBBH-29.

3/106

03_101_107_EN.indd 106

2/4/08 12:57:05

PLA

Current distribution accessories

Sigma safety terminals


Base of safety terminals made of black matte self-extinguishing polyamide-6;
terminal of brass MS-58
(DIN17660); ring of tempered steel zinc dichromate; cap made of orange
self-extinguishing polypropylene.
c Anti-cut. The connection is made using a tightening mechanism that
spreads the pressure out throughout the entire contact surface, avoiding
the occasional rubs and stresses that damage the conductors.
c Loosening proof. The ring that surrounds the brass body ensures that the
pressure exerted by the conductors cannot open the terminal and loosen
the connection.
c Total insulation. All the SIGMA terminals are supplied with a terminal cap,
avoiding any accidental contact with live parts.
All the calibres may be coupled one to the other, allowing the formation of
strips of any length. Service voltage: 500 V.

Reference

Section
m/m2

S.04

14

30

20

13

21

S.06

16

33

25

16

24

S.10

1 10

38

28

16

28

S.16

1 16

42

32

19

32

S.25/35

1 35

46

38

23

34

11

S.50

1 50

52

45

27

40

15

S.70

1 70

55

50

30

40

15

S.95/100

1 100

58

54

33

40

20

NOTE: each terminal accepts up to 2 conductors of the section indicated.

Plate/cable terminals
Plate entry and bypass by cable.
Reference

Cable bypass section


(mm2)

Plate thickness (mm)

Figure

BPCH 516

1.5 to 16

BPCH 550

1.5 to 50

BPCH 5120

16 to 120

BPCH 1016

1.5 to 16

10

BPCH 1050

1.5 to 50

10

BPCH 10120

16 to 120

10

3/107

03_101_107_EN.indd 107

2/4/08 12:57:07

PLA

Lighting accessories

Compact lamp
Compact fluorescent lamps, designed especially for use in electronic
enclosures. May be fixed with a magnet.
c Connection voltage 220 V/50 Hz.
c Consumption 11 W.
c Connection/disconnection switch.

70

c 200 V/16 A socket with earthing.

355

c Maximum ambient temperature 60 C.


c Lighting output = 75 W bulb.

90
66

Specifications

Reference

Plug

Tension

LAM-75

220 V/16 A

220 V/50 Hz

LAC-75

220 V/16 A

220 V/50 Hz

LAM-75/120

120 V/15 A

120 V/60 Hz

LAC-75/120

120 V/15 A

120 V/60 Hz

Lamp fixed with a magnet


or on 35 mm symmetric
DIN rail
Lamp fixed on a 35 mm
symmetric DIN rail
Lamp fixed with a magnet
or on 35 mm symmetric
DIN rail
Lamp fixed on a 35 mm
symmetric DIN rail

Slimline lamp
Magnetic-fixing flat lamps equipped with energy efficient light bulbs, with or
without a plug.
c Electronic ballast.
c Power: 11 W.
c Luminosity: 900 lm
c Lifespan: 10000 h.
c Plastic casing UL94 V0.
c IP20.
c Class I.
Reference

Plug

Socket

Approval

LAMS75

AC 230 V/16 A

SCHUKO

VDE

LAMX75

AC 230 V/-

VDE

LAMU75

AC 120 V/15 A

USA

UL

3/108

03_108_109_EN.indd 108

5/3/08 11:29:42

PLA

Lighting accessories

Incandescent lamp
Incandescent lamp designed especially for use in electronic enclosures.
c Connection voltage 220 V/50-60 Hz.
c Consumption 60 W.
500

c Connection/disconnection switch.
c Terminal connection entry.

Reference
LAI/OL 68

Dual lamp
1

Light fixtures designed especially for use in electronic enclosures with various
possibilities for fixing and operating.
c Energy efficient electronic lamp E27, 20 W, 220-240 V/50-60 Hz or
120 V/60 Hz.
c Lighting output = 100 W bulb.
c Fixed models connection via 2.5 mm2 terminal strip and the mobile model
via cable.

c Degree of protection IP20.


c Insulation class II.
c Conforming to EN 55014 and EN 50082-1.
Specifications
Motion-activated

Support fixing

Figure

Magnetic, using screws

and/or (1) 35 DIN rail

On/off switch with the possibility

Magnetic, via connection

of door switch, screws

and/or 35 DIN rail (1)

Mobile lamp, connection


via cable
Support for LAMDP,
LAMIN, LAMPO lamp

Adhesive or screws

Adhesive or screws

Reference

Tension

LAMDP

220 V/56 Hz

LAMDP 120

120 V/60 Hz

LAMIN

220 V/50 Hz

LAMIN 120

120 V/60 H

LAMPO

220 V/50 Hz

LAMPO 120

120 V/60 Hz

SOLAM

(1) DIN rail not provided..

100

67

396

3/109

03_108_109_EN.indd 109

5/3/08 11:29:48

PLA

Natural ventilation accessories

Ventilation devices
To connect the inside of the enclosure with the exterior atmosphere and
prevent condensation. Can be fixed onto the outside.
Reference
VM-25
VM-27

VM-25

Specifications

For coupling to the outside of all polyester enclosures

VM-27

3/110

03_110_117_EN.indd 110

2/4/08 12:58:14

PLA

Complementary accessories

Expandable nuts
Dodge-type brass nuts designed to be incorporated into the bosses of PLM
enclosures.
Specifications

TEX 8

TEX 6

Reference

For attachment to enclosures

M5

PLM-43 and 54

TEX 5

M6

PLM-64 and 108

TEX 6

M8

For the back of the enclosure

TEX 8

TEX 5

Document pocket
PP-A models made of thermoplastic in grey RAL-7035.
c Fixed with adhesive tape or screws.
For holding DIN A3-A4 or A5-sized plans.
Insulated
Reference

A4

PP-A4

A5

PP-A5

174

234

Plan size

278

22

188
Ref.: PP-A5

40

Ref.: PP-A4

Lifting the enclosures


There is a set of slings to cover the most common enclosure or suite lifting
needs.
Ref: ELS 1520.
c Table of dimensions indicating the maximum weight in kg anticipated for
each enclosure or suite. The fields highlighted indicate the dimensional range
of use planned for the lifting equipment ELS 1520.

Width (B)
Height (A)
500

750

1000

1250

1500

1750

2000

1500

113

169

225

281

338

394

450

1200

94

141

188

234

281

328

375

1000

75

113

150

188

225

263

300

750

56

84

113

141

169

197

225

500

38

56

75

94

113

131

150

(A) and (B) correspond, respectively, to the nominal height and width in mm of the enclosures
or suites.

3/111

03_110_117_EN.indd 111

2/4/08 12:58:14

PLA

Applications

DLP distribution system chassis


DLP distribution chassis set for modular equipment, to be coupled to all
models of PLA enclosures.
c Distance of 40 to 85 mm, adjustable as needed by the customer, between
the symmetric profile for equipment fixing and the interior protective cover.
c Rigid structure made of galvanised steel.
c Cover and frame insulating in self-extinguishing material in RAL-7032.
Quick mounting, without the need for screws.
c System for identifying circuits included in the standard supply.
c Earth and neutral bypass terminal block, Ref.: RBLZ/21656 (included in
standard supply).
c Possibility of installing plain mounting plates and covers to mount various
material.
In enclosures with a closed base, Ref.: PLA
are coupled directly.

the 1500 height DLP chassis

In models with open plinth-type bottom, Ref.: PLAZ should be ordered


separately from the PTZ adapter plates (see footnote).

MODELS, DIMENSIONS AND REFERENCES


For attachment to enclosures

Distribution of rows
No. of doors

Height (A)

Total chassis reference*

Width (B)

Individual chassis on twodoor enclosures reference*

Automatic switch rail


No. of plates

No. of rows
Quantity

No. of 18 mm modules

750

500

DLP 76

76

750

500

DLP 57

57

750

750

DLP 132

132

750

750

DLP 99

99

750

1000

DLP 76 + DLP 76

4+4

4+4

152

DLP 57 + DLP 57

4+4

3+3

114

1+1

DLP 76 + DLP 132

4+4

4+4

208

DLP 57 + DLP 99

4+4

3+3

156

1+1

750

1250

1000

500

DLP 114

114

1000

500

DLP 95

95

000

750

DLP 198

198

1000

750

DLP 165

165

1000

1000

DLP 114 + DLP 114

6+6

6+6

228

DLP 95 + DLP 95

6+6

5+5

190

1+1

DLP 114 + DLP 198

6+6

6+6

312

DLP 95 + DLP 165

6+6

5+5

260

1+1

1000

1250

1250

500

DLP 133

133

1250

500

DLP 114P

114

1250

750

DLP 231

231

1250

750

DLP 198P

198

1250

1000

DLP 133 + DLP 133

7+7

7+7

266

DLP 114P + DLP 114P

7+7

6+6

228

1+1

DLP 133 + DLP 231

7+7

7+7

364

DLP 114P + DLP 198P

7+7

6+6

312

1+1

1250

1250

1500

500

DLP 171

171

1500

500

DLP 152

152

1500

750

DLP 297

297

1500

750

DLP 264

264

1500

1000

DLP 171 + DLP 171

9+9

9+9

342

1500

1000

DLP 152 + DLP 152

9+9

8+8

304

1500

1250

DLP 171 + DLP 297

9+9

9+9

468

1+1

1500

1250

DLP 152 + DLP 264

9+9

8+8

416

1+1

* To be coupled to enclosures with open bottom, Ref.: PLAZ adaptor plates must be ordered separately, Ref.: PTZ 320 or PTZ 420, for 320 or 420 mm depth one-door enclosures.
PTZ 320/2P or PTZ 420/2P must be ordered for two-door enclosures.

3/112

03_110_117_EN.indd 112

2/4/08 12:58:18

PLA

Applications

FIG. 1

C-178
Cmn.

40

85

46

45

Detail of the depth-adjustable rail using a graduated support


included in the standard supply.

40

40

85

85

150

40

85

16

85

40

Covers that are quick fixing by pressure and removable using


screwdriver.
25
C

* For enclosures with a transparent KT door, subtract 5 mm.

Positioning the adjustable


chassis at a depth of
25 mm.

Label for identifying circuits included in the standard supply.

FIG. 2
(500)

(500)
(1500)

(1500)

(500)

(500)
(1250)

(1250)

(500)

(500)
(1000)

(1000)

(500)

(500)
(750)

(750)

DLP 76

DLP 114

DLP 133

DLP 171

DLP 57

DLP 95

DLP 114P

DLP 152

(750)

(750)
(1500)

(1500)

(750)

(750)
(1250)

(1250)

(750)

(750)
(1000)

(1000)

(750)

(750)
(750)

DLP 132

(750)

DLP 198

DLP 231

DLP 297

DLP 99

DLP 165

DLP 198P

DLP 264

3/113

03_110_117_EN.indd 113

2/4/08 12:58:18

PLA

Applications

Plain cover

Self-extinguishing plain cover to protect non-modular material.


c Colour RAL-7032.
c Easily machined.
c Quick mounting.

21

146

13

c 150 mm nominal height for 1 row.

25

25
D
To be coupled to nominal-width
enclosures (B)

Reference

500

CTL500/DLP

402

750

CTL750/DLP

652

500

CTL500/2DLP

402

750

CTL750/2DLP

652

Mounting plate
2 mm thick mounting plate for fixing non-modular equipment, made of
galvanised steel.
c Direct fixing to the adjustable support, which permits a depth adjustment
of between 40 and 85 mm with respect to the cover.
c 150 mm nominal height for 1 row.
Plate height

Enclosure width
(B)

Reference

150

500

PMP500/DLP

361

149

150

750

PMP750/DLP

611

149

150

500

PMP500/2DLP

361

298

300

750

PMP750/2DLP

611

298

149
E

1045

3/114

03_110_117_EN.indd 114

2/4/08 12:58:20

PLA

Applications

Blanking plate
Blanking plate of self-extinguishing insulating material for total or partial
coverage of the windows for automatic switches. Easily cut to the desired size.

Reference

Length (mm)

No. of modules

ATP6/DTM

108

ATP24/DTM

432

24

1100

Cut to size

ATP/UND

Bypass terminal blocks


Earth or neutral bypass terminal blocks with insulating plinth.
Fixed to the back of the enclosure using the metal profile.
Reference

Number of terminals 3 section in mm2

RBLZ/21656*

2 16 mm2 + 5 6 mm2

RBLZ/21686

2 16 mm2 + 8 6 mm2

RBLZ/216146

2 16 mm2 + 14 6 mm2

RBLZ/216296

2 16 mm2 + 29 6 mm2

* Included in standard supply.

Distribution bars
For the distribution in a single row of automatic switches with a total of
12 modules.
1

2
No. of poles per bar

Reference

12

BDS 1/12

BDS 2/6

BDS 3/4

BDS 4/3

No. of bars

Figure No.

3/115

03_110_117_EN.indd 115

2/4/08 12:58:22

PLA

Applications

System of 19 racks
System of very robust 19 metal racks, to be coupled to all versions of PLA
enclosures with dimensions indicated on the following page.
c Fixed and pivoting racks, permitting direct installation (using standardised
perforations) of all types of 19 modular switchgear.
c Fixing the racks on the upper part and the sides of the corresponding
enclosure, using SPLA vertical profiles, which must be ordered separately
from 750 mm height enclosures. See tables on the next page.
c Both the fixed and the pivoting racks can be installed as partial racks in
enclosures that are larger than the foreseen normal. See tables on the
next page.

c Maximum load: 3 kg per unit, with a maximum of 40 kg for pivoting racks.


c Finish: polyester-epoxy RAL-7032 paint.
c Pivoting racks with opening to 120, 5 mm key-operated double bar lock.

Fixed rack BRF 17PLA fixed using the set of two vertical profiles SPLA 100.

Pivoting rack BRP 16PLA fixed using the set of two vertical profiles SPLA 100.

Pivoting rack BRP 7PLA installed as a partial rack in enclosure. PLA 1074KT fixed using
the set of two vertical profiles SPLA 100.

19 rack support and trays for two-door enclosures


For 19 accessories, consult the VDI catalogue.
Ref.: SB/PLA.

3/116

03_110_117_EN.indd 116

2/4/08 12:58:23

PLA

Applications

19 fixed rack
BRF racks prepared to be coupled to all 750 mm width PLA enclosure
models.
From the 750 mm height enclosures, the set of two vertical profiles SPLA,
indicated in the table, must be ordered.

BRF...

For attachment to enclosures


No. of units

Reference rack

Set of two profiles

Height (A)

Width (1) (B)

500*

750

BRF 8PLA*

750*

750

12

BRF 12PLA*

SPLA 75

1000*

750

17

BRF 17PLA*

SPLA 100

1250*

750

21

BRF 21PLA*

SPLA 125

1500*

750

26

BRF 26PLA

SPLA 150

* Can be installed in taller enclosures as a partial rack, using the vertical profiles that correspond to the height
of the enclosure. In all cases, the SPLA vertical profiles must be ordered separately.
(1) It can also be installed in the 1250 mm enclosures, on the 750 mm side, using the SBPLA profiles.

SPLA...

19 pivoting rack
BRP racks prepared to be coupled to all 750 mm width and 420 mm depth
PLA enclosure models.
From the 750 mm height enclosures, the set of two vertical profiles SPLA,
indicated in the table, must be ordered separately.

BRP...

For attachment to enclosures


No. of units

Reference rack

Set of two profiles

Height (A)

Width (B)

500*

750

BRP 7PLA*

750*

750

11

BRP 11PLA*

SPLA 75

1000*

750

16

BRP 16PLA*

SPLA 100

1250*

750

20

BRP 20PLA*

SPLA 125

1500*

750

25

BRP 25PLA

SPLA 150

* Can be installed in taller enclosures as a partial rack, using the vertical profiles that correspond to the height
of the enclosure. In all cases, the SPLA vertical profiles must be ordered separately.

SPLA...

19 pivoting rack

31.75

44.45
44.45

44.45

8.5 x 8.5

12.7

465
450

465
450

8.5 x 8.5

750

300

420

77

44

325

750

420

12.7

55

485

44.45

31.75

19 fixed rack

3/117

03_110_117_EN.indd 117

2/4/08 12:58:24

PLD and ZD polyester enclosures and plinths


for LV electrical distribution

4
5

11

10 9

8a-8b

12

Self-ventilating polyester enclosures, prepared


to directly incorporate fuse blocks for electrical
distribution, conforming to DIN standards.

3/118

03_118_119.indd 118

21/2/08 11:53:20

Insulating bakelite
mounting plates in
black RAL-9005. To be
coupled directly to the
back of the enclosure.

Back with system of


bosses with inclusions
for fixing various
materials.

5 PLD enclosures are

6 Folding upper front


cover, easily accessible
from the interior of the
enclosure.

7 Lower side view once


the cable entry opening
has been accessed.

8a Detail of the profile


joined directly to the
enclosure and locks on
the left and right doors.

8b Detail of the

9 Detail of the easily


removable interior hinge
and bosses located at the
back and on the door for
fixing various materials.

10

11 View of the front


crossbar dismounted,
thus facilitating access
to the interior of the
enclosure.

designed to be installed
directly on the floor or on
ZD plinths.

Set of two metal


supports for fixing the
enclosure directly to the
floor.

enclosure with central


profile joined to the left
door and one single lock.

Expandable metal
nuts to be included in
the prepared housings in
the enclosures for fixing
of equipment, rails, etc.

4 Self-ventilating IP43
profile in standard
supply. Possibility of
IP54 by applying the
synthetic rubber seal.

12 Detail of the opening


of the blanking plate of
the auxiliar outlet.

3/119

03_118_119.indd 119

21/2/08 11:53:23

PLD-ZD

Polyester enclosures
Self-ventilated IP43
IP54 watertight (EN 60529)

PLD-86/0

Hot-press moulded fibreglass-reinforced


polyester enclosure in grey RAL-7032
(able to withstand weather conditions).

Applications
c Self-ventilated polyester enclosures, prepared to directly incorporate fuse
blocks for electrical distribution.
c Extremely versatile for any type of assembly.
c Self-extinguishing and easily machined material.
c High resistance to mechanical impacts, temperature and corrosive
environments.

Construction specifications
c Resistance to the main chemical agents and corrosive atmospheres.
c Stabilised against UV rays.
c Reversible door opening to more than 180 in every case.
c Internal hinges easily removed.
c Back of enclosure with a system of bosses equipped with M8 and M10
inclusions allowing direct fixing of the mounting plates, bar supports and/or
various materials that offers great versatility for carrying out any type of
assembly.
c Removable front crossbar that enables better access to the interior of the
enclosure.
c Canopy and body of the enclosure of equal perimeter enabling enclosures to
be coupled both laterally and posteriorly.
3/120

03_120_137_EN.indd 120

2/4/08 12:59:32

Polyester enclosures
Self-ventilated IP43
IP54 watertight (EN 60529)

PLD-ZD

Technical specifications
c Conforms to general rules for empty enclosures established in IEC and
EN 62208.
c Degree of protection IP43/IK10.
c High resistance to mechanical impacts IK10 (20 J) conforming to IEC and
EN 62262.
c Self-extinguishing, conforming to IEC 60695-2-1 (960).
c Extreme operating temperatures from 50 a 150 C.
c Suitable for double insulation mounting conforming to IEC 60439-1
(EN 60439-1).

Basic composition
c Open top with canopy.
c Completely closed base.
c Reversible door opening to more than 180.
c Three-point lock, handle operated without catch.
c Front crossbar easily removable.

Optional accessories
c Designed to be directly fixed to the ground or on a plinth ZD.
c Possibility of installing APLD mounting plates and BPLDN racks.
c Equipped with a system of bosses in the interior for fixing light fixtures.
c Possibility of IP54 when using a JED gasket.
Mounting
plates APLD

Height
(A)

Width
(B)

Plinth
ZD

Maximum No. of fuse


blocks

Enclosures

External dimensions (mm)

Depth
(C)

Reference

DIN size

No. of
doors

No. of
locks

850

465

320

PLD-85/00

00

360

APLD-85

ZD-53/00

3+E

850

590

320

PLD-86/0

495

APLD-86

ZD-63/0

4+E

850

785

320

PLD-88/1

690

APLD-88

ZD-83/1

6+E

850

1115

320

PLD-812/2

APLD-812

ZD-123/2

9+E

850

1115

320

PLD-812/2C

APLD-812

ZD-123/2

9+E

E: Screws that connect the entry to the connection.

3/121

03_120_137_EN.indd 121

2/4/08 12:59:33

Polyester enclosures
Self-ventilated IP43
IP54 watertight (EN 60529)

PLD-ZD

Dimensions (mm)
FIG. 1

PLD-85/00; 86/0; 88/1

PLD-812/2; 812/2C
1 M10 inserts for installing plates and fuse holder plinths or other material.

2 M6 inserts for fixing mounting plates, rails in general and other material.

3 Bosses prepared for M8 inserts for fixing adjustable plate supports, Ref.: TEX 8.

4 Housings for installing floor fixing supports, Ref.: SPLD. Permit the insertion of
M8 nuts, Ref.: TE/PLD-M8 for fixing various material.

5 Lock on right and left door on model PLD-812/2C.

Interior canopy prepared for bosses for inserting nuts, Ref.: TEX 6 for fixing auxiliary
material, lighting, etc.

3/122

03_120_137_EN.indd 122

2/4/08 12:59:33

PLD-ZD

Composition accessories

ZD Plinths
Hot-press moulded fibreglass-reinforced polyester plinths, in grey RAL-7032
(able to withstand extreme weather conditions).
c Self-extinguishing material; easily machined; high resistance to impacts,
temperature and corrosive environments.
c Partially ground embedded plinths prepared for direct fixing to the PLD
enclosure.
c Folding front cover, accessible from the interior.
c Bosses on the rear panel prepared for inserting nuts, Ref.: TEX 6 for M6
screws, allowing for fixing of the the neutral plate, rails and other material.
c The sides have an auxiliary outlet with a passing diameter of Pg 36
(48 mm), fitted with a plug.
c Adjustable metal interior profiles in U and L for cable fixing.
c Possibility to cut out the interior part of the side for cable passage.

TABLE OF MODELS, DIMENSIONS AND REFERENCES


External dimensions (mm)
Reference
Height (A)

Width (B)

DIN size

To couple to enclosures

Depth (C)

900

465

310

ZD-53/00

00

360

PLD-85/00

900

590

310

ZD-63/0

495

PLD-86/0

900

785

310

ZD-83/1

690

PLD-88/1

900

1115

310

ZD-123/2

PLD-812/2; PLD-812/2C

Dimensions (mm)

ZD-53/00; 63/0; 83/1

ZD-123/2

3/123

03_120_137_EN.indd 123

2/4/08 12:59:35

PLD-ZD

Composition accessories

Floor fixing supports


Set of two metal supports for fixing the enclosure directly to the floor.
Ref.: SPLD.

Enclosure reference
number

L
max.

M
max.

PLD-85/00

360

320

224

PLD-86/0

495

455

224

PLD-88/1

690

650

224

1020

980

224

PLD-812/2 and 2C

Sealing gasket
To be coupled directly to the door and the back of the enclosure, obtaining
IP54.
c Manufactured in black synthetic rubber.
To couple to enclosures

Reference

PLD-85/00

JED-85/00

PLD-86/0

JED-86/0

PLD-88/1

JED-88/1

PLD-812/2 and 2C

JED-812/2

Locks
Direct-action standard lock, operated by a retractable handle.
CATCHES FOR LOCKS
Type of key
operation, Ref.:

Reference

Double bar lock

LDB 5

TDB/PLD

Side triangle lock 8 mm

LT-8

TT7/PLD

Specifications

Lock with key type 405

TCL/PLD

Lock with reinforced key type

TLR/PLD

Manual lock

TEM/PLD

Padlock

BCME/PL

3/124

03_120_137_EN.indd 124

2/4/08 12:59:39

PLD-ZD

Mounting accessories

Mounting plates
To be coupled directly to the back of PLD enclosures.
c Insulating bakelite plates in black RAL-9005.
Possibility of depth adjustment. See notes on use of bosses 3 on page
3/122.
For attachment to enclosures

Plate
reference

Thickness
(mm)

PLD-85/00

No. of plates per


enclosure
1

APLD-85

356

304

PLD-86/0

APLD-86

481

429

PLD-88/1

APLD-88

676

624

PLD-812/2 and 2C

APLD-812*

448

396

Reference

* The reference includes the 2 plates.

Rack for fixing equipment


Insulating rail in hot-pressed fibreglass-reinforced polyester, in grey RAL7032.
c Direct lateral fixing to PLD enclosures.
c Possibility of directly fixing busbars.
Ref.: BPLDN.

3/125

03_120_137_EN.indd 125

2/4/08 12:59:40

PLD-ZD

Current distribution accessories

Adjustable ties
Made of 6.6 nylon in natural colour or black for outdoor conditions.
Reference

Use
L

minimum

maximum

White

Black

LZ25100

LN25100

100

2.5

1.6

22

LZ25200

LN25200

200

2.5

1.6

49

LZ35150

LN35150

150

3.5

1.6

35

LZ35200

LN35200

200

3.5

1.6

49

LZ35300

LN35300

300

3.5

1.6

75

LZ46150

LN46150

150

4.6

1.6

36

LZ46200

LN46200

200

4.6

1.6

49

LZ48270

LN48270

270

4.8

1.6

73

LZ46390

LN46390

390

4.6

1.6

109

LZ76390

LN76390

390

7.6

4.7

108

Tightening tools
To tighten and cut the adjustable ties to size. They facilitate wiring and save
time, preventing the packets of cables from loosening.
Tool adjustable according to the thickness of the tie. Can be used with the
following models: LZ25100 up to LZ46390. Ref.: MARK3.
A very light and ergonomic tool, the cut on the tie is done by twisting the
tool. Can be used on the following models of ties: LZ25100 up to LZ46390.
Ref.: MARK20, 21.
Admissible width ties

Reference
MARK3

2.5 4.8

Reference

Admissible width ties

MARK20

2.5 4.8

MARK21

4.6 7.6

Locking clips
Allows fixing ties from the series LZ25100 up to LZ46390 on panels up to
3.2 mm thick. Material: 6.6 nylon.
perforation
mm

Max. panel
thickness mm

SFC1

3.2

SFC2

Reference

SFC2

SFC1

Fig. 1

Figure

Fig. 2

3/126

03_120_137_EN.indd 126

2/4/08 12:59:42

PLD-ZD

Current distribution accessories

Stud
To use with soft materials: 7 mm hole, or hard materials: 8 mm hole.
Ties up to 9 mm in width can be coupled. Material: black 6.6 nylon.
Ref.: LOK01.

Tie fixing support


To attach one or two ties, mounted with a single screw. Material: 6.6 nylon.
Allows for attaching ties from the entire range.
Reference

Fixing screw

Admissible
width ties

KR6

12

18

M4

2.5 4.8

KR8

14.5

25

12

M6

2.5 7.6

Support heads
To transform normal ties into ties with fixing heads, introduce a tie into this
head before closing it on the cable bundle. Material: 6.6 nylon.

Reference

Fixing screw

Admissible
width ties

FH18

7.1

13.3

M4

2.5

FH30

9.5

17.9

4.7

M5

3.5

FH50

11.3

22.2

6.2

M6

4.7

3/127

03_120_137_EN.indd 127

2/4/08 12:59:44

PLD-ZD

Current distribution accessories

Self-adhesive support base


Permits insertion of 1 tie from 4 points at a 90 angle. Attaches ties from the
series LZ25100 up to LZ46390. Material: 6.6 nylon.
Reference

Admissible width
ties

MB3A

19.1

19.1

4.8

3.2

13.2

2.5 3.5

MB4A

28.5

28.5

5.5

20.2

2.5 4.8

adhesive support

Tie fixing support


To attach ties from any series. Material: 6.6 nylon.
Reference
LKC

Admissible width
ties mm
2.5 7.6

Fixing screw
M5

Lateral tie fixing support


Covers the head of the tie in its end, thus obtaining neater cabling. Material: 6.6
nylon.
Reference

Admissible width
ties mm

LKM/HE

2.5 7.6

Fixing screw
M5

3/128

03_120_137_EN.indd 128

2/4/08 12:59:45

PLD-ZD

Current distribution accessories

Fixing loop for tubes, hoses, etc.


2 versions, fixed and adjustable, from 5 to 25.4 mm. Material: black 6.6
nylon.
A

Reference

min. - max.

NX1

3.5

6.2

13.7

NX3

3.9

9.4

20.5

NX5

12

3.9

9.4

24

NX8*

14.3 15.8

1.3

12.6

32

NX11

17.4 20

NX14

22.2 25.4

1.3

12.6

37

4.3

1.5

16

45

* The NX8 model only has 3 adjustment holes.

NX 1-3-5

NX 8-11-14

Adjustable membrane glands


Insulated membrane glands made of PVC with entry that can be adjusted for
cables.

Fig. 1

Fig. 2

Capacity
Reference

Fig.

B*

ECPC-3

25

21.5

18

cable

Tube

3.2

13

5 a 18

Pg 9 a 11

ECPC-5

33

29.5

ECPC-6

43

38.5

26

3.2

20

5 a 26

Pg 9 a 16

36

3.2

22

5 a 36

ECPC-9

70

Pg 9 a 21

63

60

28

20

28 a 60

ECPC-15

98

Pg 21 a 48

90

87

28

23

28 a 87

Pg 21 a 48

* Mounting perforation.

3/129

03_120_137_EN.indd 129

2/4/08 12:59:46

PLD-ZD

Current distribution accessories

Protective sleeves
Small protective sleeves for cables coming out of tubes, as indicated in the
instructions for MI BT 019. Made of flexible and durable PVC, in light grey
colour.
A

PC-1

15.2

12.7

PC-2

18.6

16

Pg 11

PC-3

20.4

17.8

Pg 13.5

PC-4

22.5

19.8

Pg 16

PC-5

28.3

25.3

Pg 21

PC-6

37

33.6

Pg 29

PC-7

47

43

Pg 36

Tube
Pg 9

Reference

Useful information about Pg tubes and HIMEL accessories to be coupled


MODELS, DIMENSIONS AND REFERENCES
Tubes

HIMEL accessories to be coupled


perforations to

interior
Designation

exterior

Steel
Flexible
steel

PVC

Cables inserted*
Flexible
steel with
PVC

No. of conductors
1

Insert

Thread

4
Pg 9

15.2

12.7

12.4

12

11.1

To the perforations

To the tubes
Adjustable membrane glands

Protective Adjus. memsleeves brane glands

Plain plugs

EC-1 al EC-7
2.5

16

14

ECPC-3 al ECPC-6

PC-1

PC-2

EC-2

ECN-5 al ECN-10
Pg 11

18.6

16

15.5

14.5

10

2.5

14.2

16

EC-2 al EC-7
4

2.5

19

17.5

25

ECPC-5; ECPC-6

EC-1

ECN-5 al ECN-10
EC-3 al EC-7

Pg 13.5

20.4

17.8

17.5

16.3

16

35

10

21

19.5

ECPC-5; ECPC-6

TC-1

ECN-1
EC-3
PC-3

ECPC-3

TC-2

PC-4

EC-4

TC-3

ECN-5 al ECN-10
EC-4 al EC-7
Pg 16

22.5

19.8

18.7

18.5

17.6

50

16

10

23

21.5

ECPC-5; ECPC-6
ECN-5 al ECN-10
EC-5 al EC-7

Pg 21

28.3

25.3

24.7

23

23

70

25

16

10

29

27

ECPC-6 al ECPC-15

EC-5
PC-5

ECN-6 al ECN-10
Pg 29

37

33.6

33.5

31

31

95

35

25

16

120

50

35

25

EC-6; EC-7
38

35.5

150
47

43

41.5

41

40.3

240

35
70

50

50

48

45.5

Pg 48

54
60

50
56

48
54.2

48
52.5

47
51.4

ECPC-9; ECPC-15

TC-4

EC-6

TC-5

ECPC-6

TCP-5

ECN-6

EC-7

300
Pg 42

PC-6

ECN-7; ECN-10

185
Pg 36

ECPC-9; ECPC-15

ECPC-5
ECN-5

EC-7
PC-7

ECN-7

TC-6

ECN-10
95

70

120

95

70

120

95

150

120

150

ECPC-9; ECPC-15
55

52.5

ECN-10

ECPC-9; ECPC-15
61

58

ECN-10

* Number and section in mm2 of the conductors that may be housed inside each tube (orientative).
For more information consult the rules

3/130

03_120_137_EN.indd 130

2/4/08 12:59:47

PLD-ZD

Current distribution accessories

Sigma safety terminals


Base of safety terminals made of black matte self-extinguishing polyamide-6;
terminal of brass MS-58
DIN17660); ring of tempered steel zinc dichromate; cap made of orange selfextinguishing polypropylene.
c Anti-cut. The connection is made using a tightening mechanism that
spreads the pressure out throughout the entire contact surface, avoiding
the occasional rubs and stresses that damage the conductors.
c Loosening proof. The ring that surrounds the brass body ensures that the
pressure exerted by the conductors cannot open the terminal and loosen
the connection.
c Total insulation. All the SIGMA terminals are supplied with a terminal cap,
avoiding any accidental contact with live parts.
All the calibres may be coupled one to the other, allowing the formation of
strips of any length. Service voltage: 500 V.

Reference

Section
m/m2

S.04

14

30

20

13

21

S.06

16

33

25

16

24

S.10

1 10

38

28

16

28

S.16

1 16

42

32

19

32

S.25/35

1 35

46

38

23

34

11

S.50

1 50

52

45

27

40

15

S.70

1 70

55

50

30

40

15

S.95/100

1 100

58

54

33

40

20

NOTE: each terminal accepts up to 2 conductors of the section indicated.

3/131

03_120_137_EN.indd 131

2/4/08 12:59:48

PLD-ZD

Current distribution accessories

Bimetal BBH terminals


BBH-29

Terminals especially designed for branching cables on plates; their main


application is busbar connection.

BBH-29D

The BBH terminals are made of a tinned, hot cast copper alloy and are
suitable for connecting to a conductor of copper or aluminium indistinctly
(bimetal).
Main section mm2

Bypass section mm2

BBH-29

6-50

BBH-29C*

6-50

BBH-30

10-95

BBH-31

16-150

BBH-32

50-240

6-50

6-50

Reference

BBH-29D

BBH-29P

BBH-29DP

BBH-29DC*

6-50

6-50

BBH-30D

10-95

10-95

BBH-31D

25-150

16-150

BBH-32D

95-240

5-240

Reference

Main section mm2

Bypass section mm2

BBH-29P

6-50

BBH-29PC*

6-50

BBH-29DP

6-50

6-50

BBH-29DPC*

6-50

6-50

* Include terminal cover CBBH-29.

Plate/cable terminals
Plate entry and bypass by cable.
Section Cable
bypass (mm2)

Plate thickness (mm)

Figure

BPCH 516

1.5 to 16

BPCH 550

1.5 to 50

BPCH 5120

16 to 120

BPCH 1016

1.5 to 16

10

BPCH 1050

1.5 to 50

10

BPCH 10120

16 to 120

10

Reference

3/132

03_120_137_EN.indd 132

2/4/08 12:59:48

PLD-ZD

Lighting accessories

Compact lamp
Compact fluorescent lamps, designed especially for use in electronic
enclosures. May be fixed with a magnet.
c Connection voltage 220 V/50 Hz.
c Consumption 11 W.
c Connection/disconnection switch.

70

c 200 V/16 A socket with earthing.

355

c Maximum ambient temperature 60 C.


c Lighting output = 75 W bulb.

90
66

Specifications

Reference

Plug

Tension

LAM-75

220 V/16 A

220 V/50 Hz

LAC-75

220 V/16 A

220 V/50 Hz

LAM-75/120

120 V/15 A

120 V/60 Hz

LAC-75/120

120 V/15 A

120 V/60 Hz

Lamp fixed with a magnet or


on 35 mm symmetrical
DIN rail.
Lamp fixed on a 35 mm
symmetrical DIN rail.
Lamp fixed with a magnet or
on 35 mm symmetrical
DIN rail.
Lamp fixed on a 35 mm
symmetrical DIN rail.

Slimline lamp
Magnetic-fixing flat lamps equipped with energy efficient light bulbs, with or
without a plug.
c Electronic ballast.
c Power: 11 W.
c Luminosity: 900 lm
c Lifespan: 10000 h
c Carcasa de plstico UL94 V0.
c Plastic casing UL94 V0.
c IP20.
c Class I.
Reference

Plug

Socket

Approval

LAMS75

AC 230 V/16 A

SCHUKO

VDE

LAMX75

AC 230 V/-

VDE

LAMU75

AC 120 V/15 A

USA

UL

3/133

03_120_137_EN.indd 133

2/4/08 12:59:50

PLD-ZD

Lighting accessories

Incandescent lamp
Incandescent lamp designed especially for use in electronic enclosures.
c Connection voltage 220 V/50-60 Hz.
c Consumption 60 W.
500

c Connection/disconnection switch.
c Terminal connection entry.

Reference
LAI/OL 68

Dual lamp
1

Light fixtures designed especially for use in electronic enclosures with various
possibilities for fixing and operating.
c Energy efficient electronic lamp E27, 20 W, 220-240 V/50-60 Hz or 120
V/60 Hz.
c Lighting output = 100 W bulb.
c Fixed models connection via 2.5 mm2 terminal strip and the mobile model
via cable.

c Degree of protection IP20.


c Insulation class II.
c Conforming to EN 55014 and EN 50082-1.
Specifications

Support fixing

Figure

Magnetic, using screws

Motion-activated

and/or (1) 35 DIN rail

On/off switch with the possibility

Magnetic, using screws

of connecting door switch

and/or (1) 35 DIN rail

Mobile lamp, connection

Adhesive or screws

via cable
Support for LAMDP, LAMIN,

Adhesive or screws

LAMPO lamp

Reference
LAMDP

Tension
220 V/56 Hz

LAMDP 120

120 V/60 Hz

LAMIN

220 V/50 Hz

LAMIN 120

120 V/60 H

LAMPO

220 V/50 Hz

LAMPO 120

120 V/60 Hz

SOLAM

(1) DIN rail not provided.

100

67

396

3/134

03_120_137_EN.indd 134

2/4/08 12:59:51

PLD-ZD

Natural ventilation accessories

Ventilation devices
To connect the inside of the enclosure with the exterior atmosphere and prevent
condensation. Can be fixed onto the outside.
Reference
VM-25
VM-27

VM-25

Specifications

For coupling to the outside of all polyester enclosures

VM-27

3/135

03_120_137_EN.indd 135

2/4/08 12:59:53

PLD-ZD

Complementary accessories

Expandable nuts
Expandable metal nuts to be included in the prepared housings in the
enclosures for fixing of equipment, rails, etc.

TEX 8

TEX 6

Specifications

Reference

M5

TEX 5

M6

TEX 6

M8

TEX 8

TEX 5

Document pocket
PP-A models made of thermoplastic in grey RAL-7035.
c Fixed with adhesive tape or screws.
For holding DIN A3-A4 or A5-sized plans.
Insulated
Reference

A4

PP-A4

A5

PP-A5

174

234

Plan size

188
Ref.: PP-A5

22

278

40

Ref.: PP-A4

3/136

03_120_137_EN.indd 136

2/4/08 12:59:53

PLD-ZD

Applications

SPECIAL ARTICLES ON REQUEST


Distribution enclosures in BT
One of the main applications is the LV distribution. For this reason, they are
prepared for the incorporation of fuse blocks, insulators and busbars.

(Bases not included)

PLD-B enclosures
PLD enclosure equipped with:
c 3F + N 50 10 copper busbar.
c Floor fixing supports SPLD.
c Prepared for installing fuse block (not included).
c Triangle lock.
Reference

Dimensions (mm)

Capacity, vertical s/c III*

PLD-85/B

850 465 320

3+E

PLD-86/B

850 590 320

4+E

PLD-88/B

850 785 320

6+E

PLD-812/B

850 1115 320

9+E

PLD-812-C/B

850 1115 320

9+E

E: screws that connect the entry to the connection.

PLZD-B enclosures
PLD enclosure equipped with:
c Plinth ZD.
c 3F + N 50 10 copper busbar.
c Prepared for installing fuse block (not included).
c Triangle lock.
Reference

Dimensions (mm)

Capacity, vertical s/c III*

PLZD-85/B

1720 465 320

3+E

PLZD-86/B

1720 590 320

4+E

PLZD-88/B

1720 785 320

6+E

PLZD-812/B

1720 1115 320

9+E

PLZD-812-C/B

1720 1115 320

9+E

E: screws that connect the entry to the connection.

3/137

03_120_137_EN.indd 137

2/4/08 12:59:56

You might also like