Professional Documents
Culture Documents
Fax
Website:
www.dunia-isolasi.com
Is
ol
marketing@dunia-isolasi.com
Importer,
as
i
Glass Wool
Glass Wool
Du
ni
Features
DAF Wool glass wool insulation are lightweight flexible and resilient. They provide excellent thermal
insulation for flat or low-pitched roof using metal decking or asbestos cement roofing sheet. In place where
condensation exists. DAF Wool glass wool must be faced with a reflective alumunium foil vapuor barrier.
Product Application
DAF Wool glass wool insulation are used for external lagging air condition duct and thermal insulation of
roofs, etc.
Moisture Absorption
When tested in an atmosphere of 65% relative humidity at 20C (in accordance with British Standard 29721975) the moisture content of DAF Wool glass wool insulation is 0,1% by value.
Physical Characteristics
16 kg/m
25 mm
50 mm
30.000
0.40
CV
.
Type
Nominal Density (kg/m)
Nominal Thickness (mm)
Standard Width (mm)
Standard Length (mm)
Mass Per Unit Area
(kg/m)
15.000
0.80
Blanket
24 kg/m
32 kg/m
25 mm
50 mm
25 mm
50 mm
1200 mm
30.000
15.000
20.000
10.000
0.60
1.20
1.80
1.60
Sheet
48 kg/m
25 mm
50 mm
2.300
1.20
2.300
2.40
Alkalinity
When tested in accordance with British Standard 3958 DAF Wool glass wool insulation is slightly alkaline pH
8.
Maximum Service Temperature
The maximum service temperature for DAF Wool glass wool insulation is 340C. Where facings are applied,
the temperature tolerances of the facing adhesive limit the surface temperature to be 70C. (The appropriate
insulation thickness can be used to limit surface temperature to 70C).
0.257
1.48
0.257
0.74
0.26
0.67
3.89
0.13
1.35
7.78
Blanket
24 kg/m
25
50
0.035
0.035
32 kg/m
25
50
0.034
0.034
Sheet
48 kg/m
25
50
0.033
0.033
0.243
1.40
0.243
0.70
0.236
1.36
0.236
0.68
0.229
1.32
0.229
0.66
0.24
0.71
4.12
0.12
1.43
8.23
0.24
0.74
4.24
0.12
1.47
8.47
0.23
0.76
4.37
0.11
1.52
8.73
Is
16 kg/m
25
50
0.037
0.037
Type
Nominal Density (kg/m)
Nominal Thickness (mm)
Thermal
W/mk
Conductivity
(K)
BTU- in/hr.ft.F
Thermal
W/mk
Conductance
(C)
BTU- in/hr.ft.F
Thermal Resistance
W/mk
(R)
BTU- in/hr.ft.F
ol
as
i
CV
.
Nominal Density
(Kg/m)
16
16
24
24
32
32
48
48
Du
ni
2000
0.78
0.81
0.90
1.04
0.88
1.03
1.05
1.10
NRC
0.52
0.70
0.63
0.89
0.65
0.90
0.71
0.05
Fire Performance
DAF Wool glass wool insulation product are non-combustible. When tested in accordance with Australian
Standard 1530 Part 3 1982 Early Fire Hazard Properties Of Material Test. DAF Wool glass wool product
exhibit the following characteristics. (Test ewer conducted by AWTA)
Product Benefit
Temperature Control
Noise Reduction
Condensation Control
Energy Conversion
Personal Protection
CV
.
Du
ni
Is
ol
as
i